HomeMy WebLinkAbout52409-Z �pf So(/Tyolo Town of Southold
* * P.O. Box 1179
t0 53095 Main Rd
Uff N Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46729 Date: 12/11/2025
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 1225 Long Creek Dr Southold, NY 11971
Sec/Block/Lot: 55.-3-29
Conforms substantially to the Application for Building Permit heretofore,filed in this office-dated: 09/23/2025
Pursuant to which Building Permit No. 52409 and dated: 10/28/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Roof mounted solar panels to existing single family dwelling as applied for.
The certificate is issued to: Brett Dohnal, Kim Dohnal
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 114557 11/25/2025
PLUMBERS CERTIFICATION:
A tho ' d Signature
i
of,Safi TOWN OF SOUTHOLD
BUILDING DEPARTMENT
• o
SOUTHOLD, NY
y
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52409 Date: 10/28/2025
Permission is hereby granted to:
Brett B Dohnal
1225 Long Creek Dr
Southold, NY 11971
To:
Install roof mount solar on existing single family dwelling as applied for.
Disconnects must be located on the exterior, labeled, and readily accessible.
Premises Located at:
1225 Long Creek Dr, Southold, NY 11971
SCTM#55.-3-29
Pursuant to application dated 09/23/2025 and approved by the Building Inspector.
To expire on 10/28/2027.
Contractors:
Required Inspections:
Fees:
CO-RESIDENTIAL $100.00
SOLAR PANELS $100.00
Total S200.00
i
Building Inspector
NASSAU ELECTRICAL
SLIFFOLK INSPECTORS
159 Route 25A, Building 1 Suite B
Miller Place, NY 11764
Telephone:631 495 8136 • Fax:631 509 4538 • E-Mail:Requests@SuffolkBEI.com
CERTIFICATE OF ELECTRICAL COMPLIANCE
Applicant: Harvest Power LLC Certificate No.: 114557
Rough In Inspection Date: Final Inspection Date: Nov 25,2025
Application No.: Building Permit No.: 52409
County Tax Map No.: 055.00 03.00 029.000 ,
This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical eq�Gipmenf end/or work described
below,installed on behalf of the applicant named above,located at the premise of and not after the fina�Ips'iection date above:
4 'i
Owner: Kim Dohnal Q `Z025
Site Location: 1225 Long Creek Drive,Southold,NY 11971
Owner's Address(if different): ....,.,1t°
0 Residential O Indoor ❑Basement Serylce ❑Shed
❑Commercial 12 Outdoor ❑First Floor ❑Pool ❑Hottub
❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage
❑Addition ❑Survey 0 PV Solar ❑Generator ❑Conversion
—- --- --- ----- ------------------
0 Signs ❑Battery Storage 0 Safety Inspection Other:;
INVENTORY
Single Phase Heat Duplex Recpt Ceiling Fixture 0 Dual Func Breaker
Three Phase Hot Water GFCI Recpt Wall Fixture 0 Smoke
Main Panel AC Cond Single Recpt Recessed Fixture CO Detect
Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo
Transformer Appliance Ckt Dryer Recpt Emergency Time Clock
Disconnect 1� Switches Twist Lock Exit Fixtures Pumps
GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan
Other Equipment:System Size:10.01 kW City:22 Desc:Canadian Solar CS6.1-54TM-455H City:22 Desc:Enphase IQ7HS-66-M-US
The electrical work and/or equipment described above were inspected and was found to be in compliance with local,
state and national electrical code requirements and this office.
Applicant: Harvest Power LLC License No.: ME-68518
Date Printed: Nov 25,2025
Inspected By:Joe Coppola
Signature:
Graham Associates 256 Orinco Dr, Brightwaters, NY 11718
Building Consultants & Expeditors (631) 665-9619 Fax (631) 969-0115
November 19, 2025
Town of Southold Building Department
Post Installation Certification
Dohnal Residence — 1225 Long Creek Drive, Southold, NY 11971
Permit # 52409
Installation Date: 11/16/2025 -
Inspection Date: 11/18/2025
,r, f
0 E C 1 0 2025
To Whom It May Concern
, ;}sC; , f
The roof mounted photovoltaic system at the above referenced residence has
been installed properly in accordance with the approved plans and is
certified by Michael K. Dunn, RA, to be in compliance with the minimum
requirements of the 2020 New York State Residential Building Code; Town
Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and
2020 National Electric Code NFPA 70/2020 National Electric Code
including ASCE7-16.
If you have any further questions, do not hesitate to call.
SERE
cy5'
z
unn, RA
OE SOUTyolo
TOWN OF SOUTHOLD BUILDING DEPT.
°ycoum, 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [.. ] IN ULATIOWCAULKING
[ ] FRAMING /STRAPPING [ FINALl��
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION ' [, ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: ,To I fiSI'4 Cum cue.4w l &A4;4,
T1w�- �� � C. o•
DATE S" INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
' � b
FOUNDATION (IST). cl
Ty-
(C> C
FOUNDATION (2ND) lCIO
O
(�y
ROUGH FRAMING&
PLUMBING
C� l
71�' N
t�
INSULATION PER N.Y. y
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS O
It 6f)
- E �-. a ICCO
-
�Z
rn
O
�O
Nz
�x
H
x
d
b
H
I
a�:AsFatt�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959.
Telephone 631 765-1802 Fax 631 765-9502 htt s//www.southoldtownn . ov
fi� P ( ) ( ) P .Lr g
Date Received
APPLICATION FOR BUILDING PERMIT
n For Office Use Only D E C EJ W E
PERMITNO. 5a Building Inspector: SEP 23 2025
Applications and forms must be filled out in their entirety.Incomplete Building F)Anpartrnent
applications will not be accepted. Where the Applicant is not the owner,an Town of Southold
Owner's Authorization form(Page 2)shall be completed.
Date: q ZOZS
OWNERS)OF PROPERTY: //��
Name: �ccett l5hc\a 1 SCTM#1000-bCJS .00 - 2.DO - ON.000
Project Address: 12 Z5 Lon-i Cm.►-, br c , SoOtV 0 ., 1071
Phone#: 703) W1 - RC13 I Email: bbdOhnak @ hOte,�-l . COn,
Mailing Address: 1225 LOn Cv-ecic bfiV'L� S0 , 1J N1 , 011
CONTACT PERSON:
Name: M tla.el CR --se-
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email: hppermitting@harvestpower..net
DESIGN PROFESSIONAL INFORMATION:
Name: Michael Dunn, R.A.
Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718
Phone#: (631) 665-9619 Email: Bayblueprint@aol.com
CONTRACTOR INFORMATION:
Name: Harvest Power LLC
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email: hppermitting@harvestpower.net
DESCRIPTION OF PROPOSED CONSTRUCTION
[]New Structure ❑Addition ®Alteration ❑Repair El Demolition Estimated Cost of Project:
❑Other $ 36 it q14 • y0
Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ❑No
1
PROPERTY INFORMATION
Existing use of property: Residence Intended use of property: (no change)
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes ®No IF YES, PROVIDE A COPY.
®Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By rint name): I (Authorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF SO IFb k 1
M:Chatl Cal is Q being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the e( k
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
G day of _ 20
KAKI WON PARKER Notary Public
NOTARY PUBLIC,STATE OF NEW YORK
NO.01PA0030670
QUALIFIED IN SUFFOLK COUNTY
MY COMMISSION EXPIRES NOVEMBER06,202 ROPERTY OWNER AUTHORIZATION
(W ere a app Ican is no a owner
I, Uri' boyy\ak _residing at \22b Long CreeU_ t)r'%y{i
do hereby authorize to apply on
my behalf th To o thold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
Building Department Application
AUTHORIZATION
(Where the Applicant is not the Owner)
i
I, IJre residingat IM Loc%, CrGGk- Dt'i e-
(Print properly owner's name) (Mailing Address)
107 7( do hereby authorize µ i Gha C,1 'S
(Agent)
Harvest Power LLC to apply on my behalf to the:
Southold Building Department.
(Owner's Signattn•e) (Date)
V\L
(Print Owner's Name)
v
i
CONSENT TO INSPECTION
i
the undersigned, do(es)hereby state:
Owner(s)Name(s)
That the undersigned(is)(are)the owner(s)of the premises in the Town of
Southold,located at b r;J(- 0socli-o'la' Ny 011Q7)
which is shown and designated o he Suffolk County Tax Map as District 1000,
Section 065.00, Block 03.W Lot
That the undersigned(has)(have)filed,or cause to be fileA an application in the
Southold Town Building In ector's Office for the following: L A� -
F
IaStR��w�;an a 0.01 kW S010LE W +VN
Z2. A y TM q.55 f
4 roaF Moof4ck DaYzi
That the undersigned do(es)hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon,to conduct such inspections as they may deem necessary with
respect to the aforesaid application,including inspections to determine that said premises
comply with all of the laws,ordinances,rules and regulations of the Town of Southold.
I
The undersigned, in consenting to such inspections;do(es)so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws,ordinances,rules or
- regulations of the Town of Southold.
Dated:
(Print Name)
(Signature)
(Print Name)
Y
H 0 NJ
H A R V EST I.--)C) y
Harvest Power LLC 1 2941 Sunrise Highway,Islip Terrace,NY 11752 631-647-3402 1 harvestpower.net
December 4, 2025
Solar Permit, Cl-laseous
- Please see Electrical Certificate and Post Install Letter
Town of Southold
Permit# 52409
Customer information:
Brett & Kim Donhal
1225 Long Creek Drive
Southold, NY 11971
Kind Regards,
Michael Calise
Permit Expeditor
(631) 647-3402
Mcalise@harvestpower.net
Graham Consulting Corp. 256 Orinoco Drive,Suite A Brightwaters,NY 11718
Planning&Design (631)665-9619
September 16, 2025
Town of Southold
Building Department
54375 Rt. 25
Southold, NY 11971
Re: Brett Dohnal Residence
1225 Long Creek Drive
Southold, NY
Proposed 10.01 kWDC, 8.45 kWAC PV System
To Whom It May Concern,
Please be advised that I have analyzed the existing roof structure at the
above-mentioned premises and have determined that it is adequate to
support the additional load of the solar panels and a 140 mph wind load and
20 psf snow load without overstress, in accordance with the following:
The 2020 New York State Uniform Fire Prevention and Residential Building
Code; Town of Southold Local Code, Long Island Unified Solar Permit
Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020
National Electric Code including ASCE7-16
If you have any further questions, do not hesitate to call.
ARC
co K Do
X
\.S
cae unn, RA
PHOTOVOLTAIC ROOF MOUNT SYSTEM
22 MODULES-ROOF MOUNTED - 10.01 kWDC, 8.45 kWAC
1225 LONG CREEK DR, SOUTHOLD, NY 11971 , USA HARVEST
HARVEST POWER LLC
- -- - - ------- - - - ----- 2941 SUNRISE HIGHWAY ISLIP
SYSTEM SUMMARY: SHEET INDEX TERRACE,NY 11752
GOVERNING CODES: TEL:(801)989-3585
(N)22-CANADIAN SOLAR CS6.1-54TM-455H (455W) MODULES DATE'��B.P 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET website:www.harvestPower
(N)22-ENPHASE ENERGY IQ7HS-66-M-US MICRO-INVERTERS 2020 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN
(N)JUNCTION BOX FEE OVP- BY: 2020 NEW YORK STATE RESIDENTIAL CODE PV-1.1 ELEVATION VIEW �cCD i Chi
(E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER PV-2 ATTACHMENT DETAILS c EL K
NOTIFY BUILDING DEPARTME AT \
(N)60A FUSED AC DISCONNECT , ...�. PV-3 THREE LINE DIAGRAM
(N) ENPHASE IQ COMBINER BOX 631-765-1802 8AMTO4PM FOR THE PV-4 PLACARDS&WARNING LA LS '
FOLLOWING INSPECTIONS: COMPLY WITH ft CODES OF PV-5 ADDITIONAL NOTES ! L
1. FOUNDATION-TWO REQUIRED NEW YORK STATE&TOWN CODES PV-6-9 SPEC SHEETS
DESIGN CRITERIA: FOR POURED CONCRETE AS REQURMI AND CONDITIONS OF
ROOF TYPE: -ASPHALT SHINGLE 2. ROUGH-FRAMING&PLUMBING RETAIL STORM
NUMBER OF LAYERS: - 1
T�� PJ��JANT TO CHAP �J� VERSION
3. INSULATION OCCUPANCY R
ROOF CONDITION: GOOD TA PLANNING BLS T 3$;�P� D IPTION DATE REV.
ROOF FRAME: -2"X6"RAFTERS @16" O.C- 4. FINAL-CONSTRUCTION MUST � OF THE TOWN CODE.
STORY: -ONE STORY
BE COMPLETE FOR C.O. $Ol1Tf�flT�WN TRUSTEES USE IS UNLAWFUL
LDG.PERMIT osnst2o2s o
SNOW LOAD: -25 PSF ALL CONSTRUCTION SHALL MEET THE H.Y.S.DE�'r WITHOUT CERTIFI /
WIND SPEED :- 130 MPH REQUIREMENTS OF THE CODES OF NEW
WIND EXPOSURE:-C YORK STATE NOT RESPONSIBLE FOR St&%HD OF OCCUPANCY
DESIGN OR CONSTRUCTON ERRORS
GENERAL NOTES: J ! RA
1. INSTALLATION IN ACCORDANCE WITH MANUFACTURERRECOMMENDATIONS. ARY LOCATIONS PROJECT SITE
2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION
AND CERTIFY COMPLIANCE. +ter
3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT Q
RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT
�t'` '
� PROJECT NAME
SYSTEM.
4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN.
5. HARVEST POWER, LLC., THE SOLAR INSTALLATION ( O 0
CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL CD
RELATED REQUIREMENTS OF THE GOVERNING J N =
MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY e ! "° ° Q Y O
AHJ'S. Z LU cy) O Q
6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC = I O� — O
• ?ridS urf REQUIREMENTS INCLUDING ARTICLE 690 SOLAR � ' �' 00 OJCn
PHOTOVOLTAIC PV SYSTEMS. ' '' 0 0 Z CD -- LL
C� 1- 0
CD
7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER •"" °'•°"` °° � Z � O J Z
OF ROOF COVERING IN ADDITION TO THE SOLAR 122� Long Creek Dr, J CD I- z
EQUIPMENT. " W 0 —1 O
8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL _ 0 00 0
TO AND NO MORE THAN 6.5"ABOVE ROOF Southold, NY 11971 , Fast m N =
9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE
N
AND AT ONE GABLE EAVE. United States iamptorl c— 0 Z =
10. THIS DESIGN COMPLIES WITH 130 MPH WIND
REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S Q Q
AND ASCE 7-16. 0 North S(r a
11- WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH
ACCESS AND VENTILATION REQUIREMENTS OF THE - Riverhead SHEET NAME
UNIFORM CODE, HARVEST POWER PROPOSES THAT
COVER SHEET
ALTERNATIVE VENTILATION METHODS WILL BE rville
EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE East
DISCRETION OF THE MUNICIPALITY IN WHICH THIS SHEET SIZE
DOCUMENT HAS BEEN FILED. ., Quoaue ANSI B
12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW
YORK STATE UNIFORM FIRE PREVENTION AND 11�� X 17"
RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP SHEET NUMBER
PV-0 SCALE: NTS PV-0 SCALE: NTSr PV—O
MODULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA:
SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND
NUMBER OF MODULES=22 MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF
MODULE TYPE=CANADIAN SOLAR CS6.1-54TM-455H (455W)MODULES p BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT
MODULE WEIGHT=50.7 LBS/23.0 KG. �\ �� CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS.
MODULE DIMENSIONS= 70.9"X 44.6"=21.96 SF \ p
UNIT WEIGHT OF ARRAY=2.31 PSF \�� HARVEST
/ \ HARVEST POWER LLC
2941 SUNRISE HIGHWAY 11SLIP
NOTE:THERE IS NO FENCE AND GATE IN THIS PROPERTY 01 `\i � TERRACE,NY 11752
Q .Ceti?EC .. TEL:(801)989-3585
\
�Cj �. ebsite:www.harvest owecnet
P'� ��v (E)TREE (TYP.) �G
�� cY� J (N) ENPHASE IQ COMBINER BOX
rc %\ (E)ccUTILITY METER
(N)60A FUSED AC DISCONNECT 3
---- 6
r�h I1 �, ({ J� i R (� VERSION
r ^)� C��,. J c C"' U M `-'D I� DESCRIPTION DATE REV.
ONE- STORY HOUSE C
----- I MSP i (E)200A MAIN SERVICE PANEL BLDG.PERMIT 09i16i2025 0
WITH (E) 200A MAIN BREAKER
1p
(INSIDE)
o a ``C > J) \\ , (N) 1" PVC CONDUIT
(22) ENPHASE ENERGY r / y � J RUN 7/8"ABOVE ROOF
IQ7HS-66-M-US
MICRO-INVERTERS
ROOF#1 i /� I [n
r- \ (N)JUNCTION BOX
(13) CANADIAN SOLAR ��;� {� )"J) ) �. � �y
CS6.1-54TM-455H (455W) 24'-10"
RAFTERS= 2"X6"@16"O.0 \ --
272'AZIMUTH, 19°TILT (� 49 2 v` PROJECT NAME
Ar
ROOF#2
J (
) EXISTING `\ (9) CANADIAN SOLAR CS6.1-54TM-455H (455W) Q o
i t , c C 1 r r \ RAFTERS= 2"X6"@16 �O.0 J
DRIVEWAYC{( g2°AZIMUTH,42°TILT �
CV 2
C�` � CD
W C:) Q
LLJ� 1 _
��. 0 Lo O
O O J Z
m
0 CD
cq T-
1
�� N � *k
v% c <
SHEET NAME
SITE PLAN WITH
O\ ROOF PLAN
�,
SHEET SIZE
ANSI B
Q
I PLAN WITH ROOF PLAN SHEET NUMBER
j)S� TE
SCALE: 1/32"= 1'-0" PV-1
HARVEST
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
E q C TEL:(801;989-3585
Q� Gr / ite:www.narvest�owernet
(N) PV MODULES �`\ G ��
* r Z
LLL `�° .. a .
�}
LLLi� -
LL VERSION
L L DESCRIPTION DATE REV.
LLL (E) CHIMNEY BLDG.PERMIT 09/16/2025 o
LLL
L L L
LLL
LLL
LLL
LLL
LLL
LLL
LLL
LL
LL PROJECT NAME
L CD O
J
J �
L Q Y c)
_LL Z w rn o Q
_LLl—L O v } 0 O)
Z CD � LL
= LL � � CD Z
0 o L W
L m N O o 0
L 0 Z
L
LQ Q
(N) ENPHASE IQ COMBINER BOX (E)WINDOW co
(N)60A FUSED AC DISCONNECT (E) UTILITY METER SHEET NAME
ELEVATION
VIEW
SHEET SIZE
(' NORTH-SIDE OF HOUSE ANSI B
11" X 17"
E L EVAT_I.O N VIEW SHEET NUMBER
1 SCALE: 1/4"= V-0" PV-1 .1
ww
PV MODULES
HARVEST
P
HARVEST POWER LLC
�O 2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
r�J TEL:(801)989-3585
���r� ower.net
SEE ENLARGED VIEW 'e:www.haniest
@�6� O G G r
(E) ASPHALT SHINGLE ROOF
yam` 0, � 1 l
r �i i-,r- O
GENERAL NOTES: VERSION
1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. DESCRIPTION DATE REV.
2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 09/16/2025 0
3. BOLTS TOBE INSTALLED INTO RAFTERS.
4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE.
NOTE:-
ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY
VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES
SCALE: NTS AND ENGINEERED SPANS FOR ATTACHMENTS."
END / MID CLAMP PV MODULES
PROJECT NAME
00
M p
O
O J
_J p
Q Y c)
Z Lu rn c:)o Q
L-FOOT O U } o co
p Z O LL
(E) ASPHALT SHINGLE ROOF Z o o J 0
LL] J O
(N) UNIRAC ROOF/ DECK MEMBRANE o� J O CD
SM STANDARD RAIL m N O O
:D
° Z
— In
T-
(E) 2"X6" RAFTERS @ 16" O.0 Q
2.5" MIN.
EMBEDMENT SHEET NAME
ATTACHMENT
FLASH KIT PRO FLASHING DETAIL
SHEET SIZE
BUILDING STRUCTURE ANSI B
5/16" STAINLESS STEEL LAG BOLT 11" X 17"
WITH SS EPDM BONDED WASHER,
ATTACHMENT___ _ DETAIL LARGE VIEW 2-1/2" MIN. EMBEDMENT. SHEET NUMBER
2 SCALE: NTS PV-2
(22) CANADIAN SOLAR CS6.1-54TM-455H(455W) MODULES BILL OF MATERIALS
(22) ENPHASE ENERGY IQ7HS-66-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION .
(1) BRANCH OF 8 MODULES & SOLAR PV MODULE 22 CANADIAN SOLAR CS6.1-54TM-455H(455W)MODULES
(2) BRANCHES OF 7 MODULES CONNECTED IN PARALLEL PER BRANCH INVERTER 22 ENPHASE ENERGY IQ7HS-66-M-US MICRO-INVERTERS
COMBINER BOX 1 ENPHASE IQ COMBINER BOX
=
JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVESTPOWER
SYSTEM SIZE:-22 x 455W 10.01 kWDC
HARVEST POWER LLC
22 x 384VA= 8.45 kWAC AC DISCONNECT 1 1 IAC DISCONNECT 60A FUSED,WITH 50A/2P FUSES,240V NEMA 3R,UL LISTED 2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
TEL-(801)989-3585
website:www.harvest owecnet
L
vt�AE(,
4
8 MICRO-INVERTERS IN BRANCH CIRCUIT#1 t r
j '29 �-?
t Lv { VERSION
.-, DESCRIPTION DATE REV.
BI-DIRECTIONAL BLDG.PERMIT 09/16/2025 0
(N)ENPHASE UTILITY METER
COMBINER BOX
^, I 1-PHASE,3-W,
`—�J-------- --�-------------- ��-------- 120V/240V
I TO UTILITY GRID
I
I
7 MICRO-INVERTERS IN BRANCH CIRCUIT#2 L1 L2 N
I
_ I
15A
-- • • • I (N)JUNCTION BOX
M
I
20A
L1 L1
ti I ti i ti I I 20A (N)AC DISCONNECT 60A LINE SIDE TAP
�)-------- �)----------- ) 1 me-
FUSED,VISIBLE
-- �`------- I LOCKABLE LABELED, PROJECT NAME
I 50A FUSES,240 VAC
I L L1 20A
I Q 00 Q
7 MICRO-INVERTERS IN BRANCH CIRCUIT#3 i 200A -�
50A FUSES J
L1 L1 (E)200A MAIN O O
L • • • I L1 L1 L2 L2 p SERVICE PANEL = w O
M. CGA
IQ N N W/(E)200A `— O J Cn
I EWAY _ MAIN BREAKER
I I I I j a (TOP FED) Z CD
}O LQ O
------------ - LC) -
N O -1 0JZ
G w0
O CD
(22) ENPHASE ENERGY IQ7HS-66-M-US (3)#6 BILK RED THHN (2)#6 BILK RED THHN L-----------_�- m L0 �-
MICRO-INVERTERS (3)Q-CABLE (6) 10 AWG THWN 2 (1)#6 THHN STRANDED (1)#6 WHT THHN ---
(1) PV 6 BARE CU GND (1)#6 THHN STRANDED GREEN GROUND IN 1"PVC (1)#6 THHN STRANDED � � Z �
GREEN GROUND CONDUIT RUN GREEN GROUND IN 1"PVC GROUNDING O Z _
TERMINATOR CAP ON LAST CABLE IN 1"PVC CONDUIT CONDUIT RUN ELECTRODE SYSTEM (n Q Q
CONNECTOR Q-CABLE (TYP)
SHEET NAME
THREE LINE DIAGRAM
SHEET SIZE
ANSI B
11" X 17"
,� THREE LINE DIAGRAM SHEET NUMBER
SCALE: NTS PV-3
4„ .
WAR �N , ®WARNING - - --
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED p
COMBINER PANEL WITH RAPID SHUTDOWN
TERMINALS ON LINE AND LOAD DO NOT ADD LOADS HARVESTPOWER
SIDES MAY BE ENERGIZED IN HARVEST POWER LLC
THE OPEN POSITION LABEL LOCATION: 2941 SUNRISE HIGHWAY ISLIP
PHOTOVOLTAIC AC COMBINER(IF TERRACE,NY 11752
APPLICABLE). TEL:(801)989-3585
LABEL LOCATION: websitemww.harvestpower.net
INVERTER(S),AC DISCONNECT(S),AC 3 TURN RAPID SHUTDOWN
COMBINER PANEL(IF APPLICABLE). !�
/SOLARELECTRICSWITCH TO THE"OFF" ANELS \V R C ;�- ��
POSITION TO SHUT DOWN ; v- to
PV SYSTEM AND REDUCE 5 1 n1 �
SHOCK HAZARD IN THE s
ARRAY.RAPID SHUTDOWN SWITCH
l
VERSION
FOR SOLAR PV SYSTEM 4 DESCRIPTION DATE REV.
LABEL LOCATION: BLDG.PERMIT 09/16/2025 0
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED. ---
DISCONNECT IF REQUIRED BY LOCAL AHJ,OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
AWARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
PROJECT NAME
OVERCURRENT DEVICE
LABEL LOCATION: Q O
ADJACENT TO PV BREAKER AND ESS j CD
ocPD(IF APPLICABLE). CD 0
BUILDING SUPPLIED BY UTILITY -' N
GRID AND PHOTOVOLTAIC z w 0-) o Q
LijSYSTEM zp CD O)
1225 LONG CREEK DR U } p LL
� 0 � � O
A' '
� • • w O CD
6 J Z
J 0 CD
LABEL LOCATION: Ln = CD O
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, (N)PV MODULES (V AT EACH TURN,ABOVE AND BELOW PENETRATIONS, N $
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. T O Z =
a-
ct) Q Q
PHOTOVOLTAIC AC DISCONNECT SHEET NAME
MAXIMUM AC O.ERATING CURRENT: 35.20 AMPS PLACARD &
NOMINAL O. 40 VAC WARNING LABELS
T,,:((,E)
R BOX SHEET SIZE
LABEL LOCATION: ETER
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF CE PANEL ANSI B
INTERCONNECTION. ((N)AC DISCONNECT 11" X 17"
LABEL LOCATION: SHEET NUMBER
POINT OF INTERCONNECTION
(PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PV-4
EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER
MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND fp
METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVESTPOWER
ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL 2941TERRISE,NY117YISLIP
�� A TERRACE,NY 11752
GROUNDING ELECTRODE.
G\rJ� TEL:(801)9893585
website:www.harvestpower.net
2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL G m
E METALLIC OR PLASTIC ENGRAVED OR
ELECTRICAL CODE. LABEL SHALL B !�
MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL yJ` �,t e
BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 'R
3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION AC ,,"b� VERSION
DESCRIPTION DATE REV.
CIRCUIT" OR EQUIV. EVERY 5 FT.
BLDG.PERMIT 09/16/2025 0
4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT
SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
VOLTAGE OPERATIONAL RANGE.
6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
PROJECT NAME
7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND
ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. ? o
J
8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL Q �e o
MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED Z w °' o Q 0
= w � r� a- 0
SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE O U o -J �
ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 O Z o) > O
Z
9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT w OJ o
SUFFICE. m N F_ o O
N D 4
O ZQ Q
SHEET NAME
ADDITIONAL NOTES
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-5
HARVESTPOWE
HARVEST POWER LLC
ENGINEERING DRAWING(mm) CS6.1-54TM-455H/I-V CURVES 2941 SUNRISE HIGHWAY ISLIP
A A TERRACE,
NY
11752
�r CanadianSolar Rear View Frame Cross Section TEL:
,s 15 - - ERE �� (itemww.h owarnef)9893585
14 -- 14
A_A 13 13 NAEt
13 --_-- 3 ---
uaminy 35 10G`lC
----
--- t
M°unn,g
Hde 7 ---7in
s - _1 J.
Mounting Hole u
5 10 15 20 25 30 35 40 u so 5 10 15 20 25 30 35 e0 es 50 /Vj E\N VERSION
a ■ ,000wn^' s-c■ DESCRIPTION DATE REV.
■ 800 Wim= 25Y■
■ 600 w/W 45-C BLDG.PERMIT 09/16/2025 0
■ 4oa W11W am■
TOPHiKu6 36(All-Black) a° zOO W,m
1'34134 - 9 -
N-type TOPCon Technology
ELECTRICAL DATA I STC* MECHANICAL DATA
445 W '-' 470 W CS6.1-54TM 445H 450H 455H 460H 465H 470H Specification Data
Assembled in Me 115
C56.1-54TM 445 450r45�546014651470H TM°mlmportedromponen Nominal Max Power(Pmax) 445 W 450 455 W 460 W 465 W 470 W Cell Type TOPCon teas
Opt Operating Voltage(Vmp)32.8 V 33.OV 33.2 V 33.4 V 33.6 V 33.8 V Cell Arrangement 108(2 X(9 X 6)]
Opt Operating Current(Imp)13.59 A 13.66 13.72 1 13.78 A 13.85 A 13.91 A Dimensions 1800-1134 x 35 mm
MORE POWER 25 Industry Leading Product Warranty on Materials Open Circuit Voltage(Voc) 38.7 V 38.9 39.1 V 39.3 V 39.5 V 39.7 V (70.9 x 44.6 a 1.38 in)
Years and Workmanship Weight 23kg(50.7lbs)
Short Circuit Current(Isc) 14.48 A 14.55 14.61 14.69 A 14.77 A 14.86 A
- - - -- 3.2 mm tempered glass with anti-ref-
Module power u to 470 W Front Cover
470 W p p Module Efficiency 21.8% 22.0% 22.3% 22.5% 22.8% 23.0% lective coating
Module efficiency up to 23.0% O ratin Tem erature -40°C-+85°C Frame Anodized aluminium alloy
30 Linear Power Performance Warranty � g p ------ PROJECT NAME
Years Max.System_ Voltage 1500V(IEC/UL)or 1000V(IEC/UL) }Box IP68,3 bypass diodes
f Excellent anti-LeTID&anti-PID performance. Module Fire Performance TYPE 1(U L 61730 1500V)or TYPE 2(UL 61730 Cable 4 mm2(IEC),12 AWG(UL)
1000V)or CLASS C(IEC 61730) T6,MC4,MC4-EV02 or MC4-EV02A
Low power degradation,high energy yield 1"year power degradation no more than 1% _. Connector - � �
Subsequent annual power degradation no more than 0.4% Max.Series Fuse Rating 25 A 1550 mm 61.0 in)(+)/ CD
J
Cable Length ( D Cn O
-Subject to the terms and conditions contained in the applicable Canadian Solar Limited Application Classification Class (Including Connector)1100 mm(43.3 in)(-) J 0 _ N
Lower temperature coefficient(Pmax):-0.29%/°C, Warranty Statement Also this 25-year limited product warranty is available only for pro- -+
® increases energy yield in hot climate ducts installed and operating on rooftops n certain regions. Power Tolerance 0 10 a Per Pallet -- 30 pieces --- O F-
9Y Y •Under Standard Test Conditions(STC)of irradiance of t000 W/m2 spectrum AM 1.5 and cell tempo Per Container(40'HQ)720 feces z W M C) Q D
..........................................................................................................................._. rature of 25°C. p.
MANAGEMENT SYSTEM CERTIFICATES* _ )J Co
® Lower LCOE&system cost ISO 9001:2015/Quality management system ELECTRICAL DATA I NMOT* 0 O J
ISO 14001:2015/Standards for environmental management system TEMPERATURE CHARACTERISTICS U Li-
ISO 45001:2018/International standards for occupational health&safety CS6.1-54TM 445H 450H 455H 460H 465H 470H rr rr11
IEC62941:2019/Photovoltaic module manufacturing quality system Specification Data V z Lr) O
MORE RELIABLE Nominal Max.Power(Pmax) 335 W 339 W 343 W 347 W 351 W 354 W Temperature Coefficient(Pmax) -0.29%/°C I-- z Ln J Z
PRODUCT CERTIFICATES* Opt Operating Voltage(Vmp)30.9 V 31.1 V 31,3 V 31.5 V 31.7 V 31.9 V
- - -__ Temperature Coefficient(Voc) -0.25%/°C w O -J CD
Minimizes micro-crack impacts IEC 61215/IEC 61730 Opt.Operating Current(Imp) 10.85 A 10.91 A 10.96 A 11.02 A 11.07 A 11.12 A J
0 CD
IEC 61701/IEC 62716/IEC 60068-2-68 -- - Temperature Coefficient(Isc) 0.05%/°C LO = CD O
Take-e-way O Circuit Voltage(Voc) 36.5 V 36.7 V 36.9 V 37.1 V 37.3 V 37.5 V m
aY pen _ Nominal Module Operating Temperature 42 t 3°C N F- �
Short Circuit Current(Isc) 11.68 A 11.74 A 11.79 A 11.85 A 11.92 A 11.99 A N $
*** Heavy snow load up to8100Pa, tye 0 _ •Under Nominal Module r specvumAMIS, O Operating Temperature(NMOT),Irradiance of 800 W/m'•
C1 wind load up to 6000 Pa* •The specific certificates applicable to different module types and markets will vary,and ambient temperature 20•C,wind speed 1 m/s. r ) Li
therefore not all of the certifications listed herein will simultaneously apply to the products PARTNER SECTION v
you order or use.Please contact your local Canadian Solar sales representative to confirm
the specific certificates available for your Product and applicable in the regions in which
the products will be used.
............................................................................................................................... i e
SHEET NAME
CSI Solar Co.,Ltd.is committed to providing high quality solar
photovoltaic modules,solar energy and battery storage solu- SPEC SHEET
•The specifications and key features contained in this datasheet may deviate slightly from our actual
lions to customers.The company was recognized as the No.1 products due to the on-going innovation and product enhancement CS[Solar Co.,Ltd.reserves the right
module supplier for quality and performance/price ratio in the to make necessary adjustment to the information described herein at any time without further notice.
Please be kindly advised that PV modules should be handled and installed by qualified people who have SHEET SIZE
IHS Module Customer Insight Survey.Over the past 22 years,IL professional skills and please Carefully read the safety and installation instructions before using our Pv ANSI B
has successfully delivered over 100 GW of premium-quality solar modules. '•
:.................................................................................................................:
•For detailed Information,please refer to the installation Manual. modules across the world. ......................................................................................................._..................................................................................................................................................................
11" X 17"
........................................................................................................................................................................................................._..............................._....................
Canadian Solar(USA)Inc. March 2024 1 AN rights reserved I PV Module Product Datasheet v.1.1 C25_F23J2_TX
Canadian Solar(USA)Inc.
1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597 1 www.csisolar.com/na I service.ca@csisolar.com SHEET NUMBER
PV-6
4
HARVESTPOWEr
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
C item ill 989-3565
Q wehsfte:www.harvestpower.net
EN PHASE. ® IQ7HS Microinverter
Enclosure — Class II double-insulated,corroslon-resistant polymbrlc enclosure
Environmental category/UV exposure NEMA type 6/Outdoor'.
Commonly used module pairings' W 320-460 rating 'y
Module compatibility — 60-cell/120-half-cut-cell,56-ce11/132-half-cut-cell.and 72-call/144-half-cut-cell PV modules
Maximum input DC voltage V 59 Communication Power line comnurnication(PLC)
Peak power track ingvoltage V 38-43 Mottorng Enphaelnstaller App and monitoring options
'•..,`.- �r 4.•V�1
Operating range V 20-59 Compatible with to Gateway � VERSION
Minimum/Maximum start voltage V 30/59 Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect DESCRIPTION DATE REV.
ns required by NEC 890 and C22.1-2018 Rule 64-220.
Maximum input DC shot-circuit current A 25 CA Rule 21(UL 1741-SA).IEEE 15 47:2018(LIL 1741-SB3-EdJ for single-phase systems BLDG.PERMIT 09/16/2025 0
Maximum module I� A 2C HEI Rub 14H SRD 2A
Overvoltage class DC port — 11 UL 62109-1,FCC Part 15 Class B.ICES-0003 Class B
Compliance CA WCSA-C222 NO.107.1-01
DC port back-feed current A O This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014.NEC 2017.and NEC
2020 section 690.12 and C2Z1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors.
PV array configuration — I•I ungrounded array:no additional DC side protection required;AC side protection requires when installed according to manufacturer's instructions.
ax.20 A per branch circuit
Peak output power VA 384 0 240 VAC.369 0 208 VAC
Maximum continuous output power VA 384®240 VAC,369®208 VAC
Nominal(L-L)vofiage/Range' V 240/211-264,208/183-229
Maximum corrtirwouscutput current — 1.60 A(240 V),1.77 A(208 V)
Easy to Install Nominal frequency Hz 60
IQ7HS Microinverter
•Lightweight and simple Extended frequency range Hz 47-68
The high-powered,smart grid-ready IQ7HS Mkroinverter with Integrated MC4 Faster installation with improved. AC short-circuit faun current over three
connectors dramatically simplifies installation while achieving the highest system lighter two-wire cabling cycles Arms 4.82
efficiency. Built-in rapid shutdown compliant Maximum units per 2C A(L-0 branch
(NEC 2014.2017.2020.and 2023) circuit' — 10(240 VAC),9(208 VAC) PROJECT NAME
Produetlw and reliable OvervNtage class AC port — III
® AC port back-factor setting
current n1A 18
•Optimized for high powered Q Q Q
60-call/120-half-cut-cell.66-cell/ Power factor setting 1.G �V/J
132-half-cut-cell,and 72-cell/ power factor(adjustable) 0.85 leading...O.a5 lagging fV O
144-half-cut-cell PV modules LI— .—J
Part of the Enphasa Energy System,the 107HS Miaoimerters extend the reliability More than a million hours of testing J 0 _ ^M1 TO
107HS Microimerters integrate with the standards set forth by Previous generations Class II double-insulated enclosure CEC weighted efficiency % 97.0 C 240 V.96.5 Q 208 V `V +
r
l0 Gateway.10 Battery,and the and undergo over a million hours of power- UL ListedMECHANIC t O
Enphase Installer App monitoring and on testing,enabling Enphase to provide an z Uj � O Q D
analysis software industry-leading warranty of up to 25 years. Ambient temperature range °C(°F) -40 to 60(-40 to 140) = 11J = Q n O
Smart gr s with y O O J V J
Relative humidity range % 4 to 100(condensing r—
•Complies with advanced grid support,
..esms� voltage.and frequency® ride-firo+9 h DC connector type — Staubll MC4 Z Q >
requirements Dimensions(H-W°D) mm(in) 212(8Z)•175(6.9)°302(12)without bracket U O Remotely updates t respond to — —
changing grid requirements
Weight kg(Ib) 1.1(2.4) (D is _
on"ura 1 v r'n ri motile, Cooling Natural convection—no fans Z 0 LO
LO J 7
Connect PV modules quickly and easily Ci Microimerters are UL Listed Meets CA Rule 2111741-SA)and Approved for wet locations — Yes W O J O
to the 107HS Microinverter,that have as PV rapid shutdown equipment and IEEE 15472018(ILL 1741-58.3rd Ed)for
integrated MC4 connectors. conform with various regulations when single-ph.sesystems Pollution degree — P03 f'1/ J O O
inst O alled according to the manufacturer i /L'yL\ y/•)
instructions. I r r
I-
CV D �$
� 0 Z _
'Paring PV nwduW wan wattage above the kmit mry resat in additbrW ekppingloeaaSw[fn cwmP.tnirdy Wc,YrtartermhssacwNnsta4rLmiaainvwars/dMatoc '^
02024Eiplrw Fna.gy.AIrghh naervad Erphaaa.tMaand CClogos.IQ aM<arta�n oMar marts IatM at t Ncmialvdtagsrange canboa dodbe ,drvt,Wifr mdbvthe,rtisty. v,
enphase.corm/eadamwkvsaoe-mideBnes are nadamarks of Enphsse Ensgy.Iric.m the U5.ard other coumr�s. s LYnits mry ,rry.Rater to bcel rapiernwita to Man the nunibar d maoinwoars fx branch yov yr
Datar6jacibehange DSH W562'LO-EWU5-2024-06-02 DSH-00562-20-EN-0-2024-08-02 DS.00562-10-EWUS-2024-08-02
SHEET NAME
SPEC SHEET
SHEET SIZE
ANSI B
1111 X 17"
SHEET NUMBER
PV-7
1 kill SOLARMOUNT ::• UNIRACHARVEST POWER ILILC
:.
BETTER DESIGNS N
TRUST THE INDUSTRYES BEST DESIGN TOOL CONCEALED UNIVERSAL 0
Start the, design process for every project in our U-Budder on line design tool. ENDCLAMPS
It's a great Nay to save time and money.
BETTER SYSTEMS f
VERSION
ONE SYSTEM-MANY APPLICATIONS - - DATE
Quickly set,modules flush to the roof on steep pitched roots.Orient a large variety 09 .
25
of modulesi Portrait or Landscape.Tilt the system pt mi Hai r low slow roots. END CAPS INCLUDED —==
Componen(savailahlein mill,clear,and dark finishes tooptimizeyour design financials =` WITH EVERY ENDCLAMP
and aesthetics.
BETTER RESULTS
MAXIMIZE PROFITABILITY ON EVERY JOB
CONCEALED Trust Unirac In help you minmute both system and labor costs from the time the job is
UNIVERSAL quoted to thetime yourteamsget off the roof.faster installs.Less Waste.More Profits.
CLAMPS UNIVERSAL SELF
eUNIRAC BETTER SUPPORT STANDING MIDCLAMPS
25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Professional support for professional installers and designers.You have access to PROJECT NAME
YEAR our technical support and training groups.Whatever your support needs.we've got
OPTIONAL you covered.Visit Unirac.com/solarmount for more information.
FRONT TRIM fUEE-SYSiEh1
�VAflflilNiY j —I l U BUILDER ONLINE DESIGN
= --
• —s3 TOOL SAVES TIME& MONEY
')ONOING&GROUNDINGIECHANICAlLOADING _, Visit desigo.umrac.com � •
9 o ' � _ - •
� UL2703SYST[M FIRE CLASSIFICATION _
•
�r
•
UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT
CD• •
• CD 0
•
• •I I I I I I UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT -
r r •rr i r• 1 i •r i r r r i .r EXPERIENCE DUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION •
�. . 1
TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY
Unirac s leQhnical support team is dedicated to answering Unuac is the only TV mounting vendor with ISO Don't leave your project to chance.Unirac has the
questions&addressing issues in real time.An online certifications for 9001:2008.14001:2004 and OHSAS financial strength to back our products and reduce your risk. SHEET NAME
THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING stamydfdocuments dtechnicaldtang sheetgreatly f800120m1.which mean.Tesecerticat highest
onsdeonstrt excHavepeace of ionalgalind tyknowingyou are MOUNTscoveredbroducts of
5year
stampedlettersantltechnicaldatasheetsgreatly for fit,form,and function.These certifications demonstrate ezceptionalquality.SOLARMOUNTiscoveredbya25year SPEC SHEET
simplifies Our permitting and project planning process. our excellence and commitment to first class business practices. I im ited product warranty and a 5 year I i mite it fin ish warranty. SHEET S17E
BEST INSTALLATION EXPERIENCE-CURB APPEAL•COMPLETE SOLUTION•LINIRACSUPPORT i ANSI B
ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN
FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248 2702 FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248 2702
a
Unirac State Letter-NY HARVEST
Tectonic Tectonic Tectonic WOs 12,20
August 12 7.2424 HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
;..,«.,..««+•�.,,,.v"` TERRACE,NY 11752
G\s TEL (801)989-3585
August 12, 2024 ■ Metal Roof: Standing Seam Attachments, PM-9000s, and PM Adjust Slotted '�, ebsite:www.harvest owernet
Tile Roof: Solar hooks, Flashkit Tile Replacement JR)Unirac Q
Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered
9 9 -�
1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction. The design tool 4. s
Albuquerque, NM 87102-1545 and Unirac do not evaluate the existing roof structure, or the PV panels themselves. 0
,+. a,
TEL: (505)242-6411 See the construction and installation drawings and manuals for additional
information provided by Unirac.
RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) Sincere) ty `it�O,
ROOF PV PANEL SUPPORT SYSTEM y- VERSION
OF NE�V
STATE: NEW YORK Tectonic Q�` A. G yO DESCRIPTION DATE REV.
TECTONIC WORK ORDER#:12557.25 °�`O (i 9� BLDG.PERMIT osnsrzozs o
AK .
The Unirac SOLARMOUNT (SM) Photovoltaic Panel Support System is a proprietary Q a Cr
framed photovoltaic panel support system that is installed on a roof. Tectonic y i
Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has
reviewed the SM design methodology along with the U-Builder tool; a Unirac online °A 071249
design tool. The review included the following SM products, SM Light, Heavy Duty, s1ONP 08/12/2024
and Standard rail with both the standard and pro hardware.
Antonio A. Gualtieri, P.E.
Tectonic has determined that the design is a rational approach and follows the Executive Vice President
structural requirements of the following reference documents:
Codes/Standards:
PROJECT NAME
a 2020 Building Code of New York State.
a 2018 International Building Code by International Code Council. < o Q
a ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by J
American Society of Civil Engineers with provisions from SEAOC PV-2-2017. rn O
a 2020 Aluminum Design Manual, by Aluminum Association. J 0 N =
Q Y ti o
This letter certifies that the structural analysis of the racking members,connections, Z Lu rn o Q
and components directly related to Unirac's system are in compliance with the 2 LLI cM 0- O
above codes. The design methodology is acceptable under components and O o _J 0
cladding loads associated with the building's roof structure when the system is p U Z p }. LI_
installed in accordance with manufacturer specifications. If the loading criteria does 0 to l_- O
not meet Unirac's specifications, owner shall contact Unirac for a site-specific 1— Z Li o Z
certification. � OJ JO o
co Lr) = o O
Attachments approved for the SM system to the structure include the following N I— U ~
and is installed per Unirac's U-Builder report and installation guides: 0 Z
Z
• Shingle Roof: L-Foot Flash kit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, O Q Q
and Flash Kit Pro SB
SHEET NAME
Project Contact Info Project Contact Info
SPEC SHEET
1279 Route 300 1 Newburgh,NY 12550 1279 Route 300 1 Newburgh,NY 12550
845.567.6656 Tel 1 845.567.8703 Fax 845.567.6656 Tel 1 845.567.8703 Fax
SHEET SIZE
tectoNcengineermg.com tacbnicengineering.corn page 2 of 2 ANSI B
Equal Opportunity Employer EquW Oppmtulity Employer
11" X 17"
SHEET NUMBER
PV-9