Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52295-Z
hoy�ap4 SOUIyo�° Town of Southold * * P.O. Box 1179 o� 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46719 Date: 12/09/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2055 Grand Ave Mattituck, NY 11952 Sec/Block/Lot: 107.-8-5 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 08/18/2025 Pursuant to which Building Permit No. 52295 and dated: 09/25/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Donald Deerkoski Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114178 11/13/2025 PLUMBERS CERTIFICATION: Au o ' d Signat e �o4aofSo&ryo`Q TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE �p��cou►m,�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52295 Date: 09/25/2025 Permission is hereby granted to: Donald Deerkoski PO BOX 248 Mattituck, NY 11952 To: install roof-mounted solar panels to an existing single-family dwelling as applied for. Premises Located at: 2055 Grand Ave, Mattituck, NY 11952 SCTM# 107.-8-5 Pursuant to application dated 08/18/2025 and approved by the Building Inspector. To expire on 09/25/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total S200.00 ------ ---------------------- Building Inspector r }. Nov 2 0 2025 .' NASSAU ELECTRICAL : SUFFOLK INSPECTORS S 159 Route 25A, Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 • E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: SUNRUN/Samy Mounas Certificate No.: 114178 Rough In Inspection Date: Final Inspection Date: Nov 13,2025 Application No.: Building Permit No.: 52295 County Tax Map No.: LIPA Solar App No.: 9625516451 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: DONALD DEERKOSKI Site Location: 216R-055DEER,2055 Grand Ave,Mattituck,NY 11952 Owner's Address(if different): 0 Residential O Indoor ❑Basement ❑Service ❑Shed ❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub ❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage ❑Addition ❑Survey ®PV Solar ❑Generator ❑Conversion ❑Signs ❑Battery Storage ❑Safety Inspection Other: INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture Dual Func Breaker Three Phase Hot Water GFCI Recpt Wall Fixture Smoke 0 Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel F7 AC Blower Range Recpt LED Lighting Smoke CO Combo Transformer Appliance Ckt Dryer Recpt Emergency Time Clock Disconnect 60 amp Switches Twist Lock Exit Fixtures 0 Pumps GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan 0 Other Equipment:System Size:9.430 kW Qty:23 Desc:ELIN ENERGY(SIRIUS PV):ELNSM54M-HC-410 Qty:1 Desc:SOLAREDGE TECHNOLOGIES:SE760OH-USMN The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: SUNRUN/Samy Mounas License No.: 33878-ME Date Printed: Nov 13,2025 Inspected By:Joe Coppola Signature: ho�alaF SOUIyOIo TOWN-OF SOUTHOLD BUILDING DEPT. ^ouffm� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /.STRAPPING [ .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE' SAFETY INSPECTION [ -] FIRE RESISTANT CONSTRUCTION [ ] FIRE.RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O ( ] RENTAL REMARKS: d, O . DATE ��o�1`'o�-� INSPECTOR NOV 1 9 2025 J October 31, 2025 Subject: Post Installation Approval Letter Job Number: 216R-055DEER Client:DONALD DEERKOSKI Address: 2055 Grand Ave Mattituck NY USA 11952 Building Permit: 52295 To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the approved plan set and that any potential modifications from those plans meet the intent of the approved plan set. I certify that the PV racking system's attachments have been observed to be installed in conformance with the approved plan set. The installation complies with the code provisions listed below. Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS • Basic Wind Speed V= 128 mph,Exposure Category B, • Ground Snow Load=25 Psf Sincerely, FN 4130120 OF e Digitally signed by Humphrey Kariuki Date:2025.10.31 RO�FS 1 10:08:34-04'00' 6755 Business Parkway, Suite 210 Elkridge,MD 21075 1 (667)686-8469 1 hkariuki@gmail.com FIELD INSPECTION REPORT I DATE T- COMMENTS FOUNDATION (1ST) ------------- ------------------------ -------------- - FOUNDATION (2ND) ROUGH FRAMING& PLUMBING Vl INSULATION PER N. Y. STATE ENERGY CODE kv? pate O. - FIN AL ADDITIONAL COMMENTS �,�� - - � - 10 mos, --- %:24 m -------- ...... X ------------- 0 �o�osufFoc,��oG TOWN OF 50UTHOLD—BUILDING DEPARTMENT yz Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT C� For Office Use Only PERMIT NO. 00 Building Inspector: Applications.and forms must be filled out in their entirety:Incomplete uidctdn ®ep��cs applicationsswill not be accepted. Where the Applicant is-not the owner";an �ToY��o 50 Owner's Authorization form(Page 2)shall be completed. Date: / OWNER S)OF PROPERTY: Name. SCTM#1000� ��../_._'._ Project Address: Phone#: 4072210479 Email: ------.. .---.-____-___ _.__..__ __-_.-_.-___ _.. _ __._-___- .--____. _. _ _------kdeerkoski1.@outlook.com___-- Mailing Address:PO Box 248 Mattituck, NY 11952 CONTACT PERSON. "J Name:Sunrun Installation Services Mailing address:177 Cantiague Rock Rd, Westbury_,_ NY 11590 Phone#: EmaiI:LlPermits sunrun.com DESIGN PROFESSIONACINFORMATIONc Name dr Mailing Address: _ _ - - - - --- �� - -- -i- _ /� -- --- Phone#: - - Email: oa� CONTRACTOR INFORMATION: Name`177 Westbu Roc u Cantia e k Rd, , N 9 . _- -- ----___ rYY 11590 Mailing Address:177 Cantia ue Rock Rd Westbury, NY 11590 Phone#: _ mail-177 ar zg��P R�Rd \A1P-qthiiWr,� 9 — .DESCRIPTION,OF PROPOSED CONSTRUCTION. . ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Esti ted Cost of Projec DOtherSolar $�j�, �� �b Will the lot be re-graded? ❑Yes IQ4 o Will excess fill be removed from premises? ❑Yes o 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and estrictions with respect to this property? ❑Yes ❑ IF YES, PROVIDE A COPY. heck Box-After Reading: The,owner%contractor/design professional is responsible.for Jall drainage and storm'water issues as provided by Chapter 236 of the Town Code.,APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk;,County,New York and other applicable Laws,Ordinances or Regulations,for the,construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,'ordinances,building code, housing code and regulations and to admit But inspectors on'premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law: , Application Submitted By(print name): ®Authorized Agent ❑Owner Signature of Applicant: DONAI' D66kk'0SKI Date: 08/09/2025 STATE OF NxTexas \��o<\? John aTlll"4e/ SS: _ ; = ID NUMBER N .y x 13240917.9 COUNTY OF Tarrant �. ��j�9fF�F•'tQ COMMISSION EXPIRES �g4gryq441j111\�\�\ March 18,2028 DONALD DEERKOSKI being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Notary Public, State of Texas 9th day of August 2025 Notary Public Electronically signed and notarized online using the Proof platform. PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I� DONALD DEERKOSKI residing at 2055 Grand Avenue do hereby authorize Sunrun Installation Services —�Y Si/.e f(/P!/fomapply on my behalf to the Town of Southold Building Department for approval as described herein. MAO DEEi2KOSff 08/09/2025 Owner's Signature Date DONALD DEERKOSKI Print Owner's Name 2 + D� OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE August 13,2025 OF OCCUPANCY RE: CERTIFICATION LETTER Project Address: DONALD DEERKOSKI RESIDENCE 2055 GRAND AVE MATTITUCK,NY,USA 11952 Design Criteria: Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=II -Wind Speed=128 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=25 psf -ROOF AR-01:2 x 8 @ 16"OC,Roof DL=11 psf,Roof LL/SL=20 psf(Non-PV),Roof LUSL=20 psf(PV) -ROOF AR-02:2 x 8 @ 16"OC,Roof DL=11 psf,Roof LL/SL=20 psf(Non-PV),Roof LUSL=15.8 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. E13020d. tDigitallysi ned ba/3o/zo pF NFL, � \/Sincerely, N, Y0 J Humphrey Kariuki AP R VED AS NOTE m - �2� rF._Date,2025.08.13 95450 DATE. �o2s" e.a� a RosstoNP� 12:57:17 -04'00' f FEE ` aY NOTIFY BUILDING COMPLY WITH ALL CODES OF DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE NEW YORK STATE&TOWN CODES FOLLOWING INSPECTIONS: AS REQUIRED AND CONDITIONS OF 1. FOUNDATION-TWO REQUIRED S0 HOLDT NZBA FOR POURED CONCRETE _SOUTHOLD WN PLANNING BOARD 2. ROUGH-FRAMING&PLUMBING 3. INSULATION SOUTHO TOWN TRUSTEES 4. FINAL-CONSTRUCTION MUST M Y.S.D BE COMPLETE FOR C.O. S I OLDHn ELECTRICAL ALL CONSTRUCTION SHALL MEET THE """"""'•"^-�--• REQUIREMENTS OF THE CODES OF NEW SC INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS 6755 Business Parkway,Suite 210 Elkridge,NID 21075 1 (667)686-3469 1 hkariuki@�;maii.com pg 1)f 7 SHEET INDEX SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION .SYSTEM SIZE:9430W DC,760OW AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE WITH 2O18 IRC/IBC/IEBC,7-16 ASCE& PV-1.0 COVER SHEET •MODULES:(23)ELIN ENERGY(SIRIUS PV): 2018 NDS,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. ELNSM54M-HC-410 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. EXp.datc PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. 4/30/20 PV-3.0 LAYOUT OF NE SE760OH-USMN PHOTOVOLATIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER.SYSTEM �� W y �P •RACKING:ALPHATRACK TO FRAMING-SNR-DC-00370 COMPLIES WITH 690.41(A) C BEY KAN,q D,Q PV-4.0 ELECTRICAL •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-5.0 SIGNAGE 1 •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. = s" PV-5.1 SIGNAGE 2 •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. 0 •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY = BOUNDARIES PER NEC 690.12(1). 95450 �O •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). ,p •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. OFfSSIONP'N •13.85 AMPS MODULE SHORT CIRCUIT CURRENT. •17.31 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)). f� Digitally signed by�,Hu prey Karlukl Date: 2025.08.13 11 :16:23 -04'00' suiRul 00825-ME ABBREVIATIONS VICINITY MAP 177CMTM UEICXIC .NESTBURY.NY11550 A AMPERE �� ; PHONE 8B5540 U87 FAJt SC516B M21 AC ALTERNATING CURRENT CUSTOMER RESIDENCE: AFC ARC FAULT CIRCUIT INTERUPTER A• A o DONALDDEERKOSKI AZIM AZIMUTH Y� t f 2055 GRAND AVE,MATTITUCK, Y� COMP COMPOSITION '" ` - NY,USA 11952 DC DIRECT CURRENT _ - TEL.(407)221-0479 (E) EXISTING �,s✓j1'`Y,� r f APN:1000-107-00-08-00-005-000 EBB ENERGY STORAGE SYSTEM _ I y,yp'`"Y / PROJECT NUMBER: MSP MAIN SERVICE PANEL �`, 216R-055DEER 0.�..:...wH..-,.,: (N) NEW 1 ('• - .r"�a m / - \•; y.= E)'' r DESIGNER: (415)580-6920 ex3 ; PRE-FAB PRE-FABRICATED '� < 1d-'-- '•s-' j MCDOWELLSERRANO PSF POUNDS PER SQUARE FOOT - �°'."t� \ i � - SHEET PV PHOTOVOLTAIC - _ _ - REV NAME DATE COMMENTS EnT-NSFORMERUESS SHUTDOWN DEVICECOVER SHEET � " \ `A6°'0aip ^. l I .. . REV'A 8/12/2025 slyPAGE S ', PV-1.0 SITE PLAN-SCALE=3/32"=1'-0" SITE PLAN DETAIL-SCALE=1/64"=1'-0" ® (N)ARRAY AR-02 Fxp.date 4/30/20 OF NFL, y0 G) g ei KA7yJ4 1p (E)STAIRS ROOF PATHWAYS v r = a•'• (3-TYP) o ,. m m 95450 (E)RESIDENCE ��\ (E)DETACHEDROFESSIONP�� GARAGE � �•'.a �. ES�\e\o Digitally signed (E)DRIVEWAY �Y:-� byHO m ph rey Ka'ri u ki Date: O[] MP 2025.08.13 11:16:33 -04'00' 0 SE INV ROOF PATHWAYS (3 TYP) SLnRLn FIRE SETBACKS (18"TYP) (N)ARRAY AR-01 00825-ME 177 CAMwGUE ROOK ROAD.NESTBURY.NY 11 PHONE 8055<05167 FAX BCS]68]033 NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE CUSTOMER RESIDENCE: SPRINKLERS. DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, ARRAY DETAILS: NY,USA 11952 • TOTAL ROOF SURFACE AREA:2980 SQFT. ARRAY TRUE MAG PV AREA TEL.(407)221-0479 • TOTAL PV ARRAY AREA:483.5 SO FT. PITCH AZIM AZIM (SQFT) • PERCENTAGE PV COVERAGE: APN:1000-107-00-08-00-005-000 (TOTAL PV ARRAY AREAlfOTAL ROOF SURFACE NOTES: AR-01 10° 247° 238° 315.34 PROJECT NUMBER: AREA)A 100=16.2% NO GATES OR FENCES 216R-055DEER PRESENT ON SITE AR-02 21° 67° 58° 168.18 LEGEND SCALE:NTS AC COMMUNICATION SOLAR DESIGNER: (415)580-6920 ex3 NOTE:NOT ALLIMISIN LEGEND SM SUNRUN METER O AC DISCONNECT(S) O MD MICROGRID INTERIOR EQUIPMENT WILL APPEAR IN SITE PLAN WIRES INTERCONNECT DEVICE L J SHOWN AS DASHED MODULES MCDOWELL SERRANO DC GROUNDING + - SE SERVICE ENTRANCE pM DEDICATED PV METER ❑DC DISCONNECT(S) MA METER ADAPTER BATTERY SHEET O ELECTRODE F SITE PLAN 0MP MAIN PANEL SEM SOLAREDGE METER INV INVERTER(S) GP GENERATION PANEL BI BACKUP INTERFACE ENERGY STOR SYSTEM(ESS)AGE SNR MOUNT REV:A 8l12/2025 SP SUB-PANEL AM ACREL METER LC PV LOAD CENTER CB IQ COMBINER BOX BP BACKUP LOADS PANEL SNR MOUNT&SKIRT PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait g yp Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:25 PSF WIND SPEED: AR-01 COMP SHINGLE-ALPHATRACK 2-Story 2X8 RAFTERS 13'-1" 16" ALPHATRACK TO FRAMING-SNR-DC-00370 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. COMP SHINGLE- FASTENERS: AR-02 ALPHATRACK 1-Story 2X8 RAFTERS 12'-5" 16" ALPHATRACK TO FRAMING-SNR-DC-00370 5'-4" 2'-l" 4'-0" 2'-0" STAGGERED (1)5/16"DIA S.S.LAG SCREW:2.5' MIN EMBEDMENT INTO FRAMING D1-AR-01-SCALE:3/16"=V-0" Exp.date AZIM:247° 4/30/z0 (EOFNEW PITCH:10° KAy�q/0 P =w C I—4'TYP 95450 —$ �OFfSS10NP�"� !fi Dig ita°Ily s.i:gned�, byHumphrey / Karluki Date: 2025.08.13 k-3'— 30'-2" —�,_,, 11:16:41 -04'00' D2-AR-02-SCALE:3/16"=1'-0" AZIM: SU1 RU1 PITCH:21:21° El B 00825-ME 177 CAN-GUE ROCK ROAD,NESTBURY.NY 11590 PHONE905S<0.5487 FAX 645268.2022 CUSTOMER RESIDENCE: DONALD DEERKOSKI 1-5-4 TYP { v 2055 NY,USA AND 2VE,MATTITUCK, 13'-3" TEL.(407)221-0479 STRUCTURAL NOTES: APN:1000-107-00-08-00-005-000 • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL PROJECT NUMBER: STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ 216R-055DEER }-4'TYP { INSTALLATION. • IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF DESIGNER: (415)580-6920 ex3 ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS MCDOWELL SERRANO 2'1" NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" SHEET BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE LAYOUT 15'-1" 2'-4"{- REDUCED BY 50%. --ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF REV:A 8/1 212 0 2 5 ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: �E OF Nrh, 98298224 ® ACCOUNT#: �pK HO(/� UTILITY 9625516451 GRID — SUPPLY SIDE TAP EXISTING NOTE:TOTAL PV BACKFEED=40A 108135 GENERATOR USED FOR INTERCONNECTION Exp.Dp�O�sr ONp��� EXISTING OPEN CALCULATIONS £$$� 6/30/202 TRANSITION GEN / \` TRANSFER Digitally signed SWITCH > 1 1 C EXISTING 150A (N)LOCKABLE by,. estor BLADE TYPE SOLAREDGE TECHNOLOGIES: r MAIN BREAKER FUSED AC i SE7600H-USMN Houghton DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES Date: 3 2 OR EQUIVALENT 1 ELIN ENERGY(SIRIUS PV): EXISTING 200A _ p "MAIN PANEL o�,�, ✓ �,i + �// (23)MODULESA10 2025.00.�3 OPTIMIZERS WIRED IN: 1 1:1 7:09 -04'00' LOADS FACILITY 40A FUSES (1)SERIES OF(12)OPTIMIZERS FAGtItt _GRouw SQUARE D LOAD RATED DC DISCONNECT (1)SERIES OF(11)OPTIMIZERS D222NRB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A COMPLIANT U650 120/240VAC sulnul CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 00825-ME 17 0a55<0Sa8]�ROAD,—THURY,Wl- 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER PS&5Ifi—1 CUSTOMER RESIDENCE: 2 1"PVC OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHNlTHWN-2 DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, 3 1"PVC OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 NY,USA 11952 4 1"PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 TEL.(407)221-0479 AP N:1000-107-00-08-00-005-000 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 U650 OPTIMIZER CHARACTERISTICS: 216R-055DEER MODULE CHARACTERISTICS SYSTEM SIZE: 9430 W MIN INPUT VOLTAGE: 8 VDC SYSTEM OPEN CIRCUIT VOLTAGE: 12 V MAX INPUT VOLTAGE: 60 VDC DESIGNER: (415)580-6920 ex3MCDOWELL SERRANO ELIN ENERGY(SIRIUS PV): 410 W SYSTEM OPERATING VOLTAGE: 380 V MAX INPUT ISC: 15 ADC ELNSM54M-HC 410 MAX ALLOWABLE DC VOLTAGE: 480 V MAX OUTPUT CURRENT: 15 ADC SHEET OPEN CIRCUIT VOLTAGE 37.32 V SYSTEM OPERATING CURRENT: 24.82 A SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL MAX POWER VOLTAGE 31.05 V SHORT CIRCUIT CURRENT 13.85 A REV:A 8/1 212 02 6 PAGE PV-4.0 INVERTER 1 OWA,RN I N G NOTES ANDAND LABELS SHALL OHS: I I WA RNiI NG • • • • • •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS IR THE NEC 2017 ARTICLE - 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM VOLTAGE: 480 IF REQUESTED 81'THE LOCAL A.I. COMBINER PANEL •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM CIRCUIT CURRENT: 30ADC WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING MAX RATED• • METHOD AND SHALL NOT BE HAND WRITTEN. O F N SIDES MAY BE ENERGIZED IN �F- £;7 LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT '`Q' y THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF • 15 INVOLVED. StpR H000 APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY �• 24. I' LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), INVERTER(S),DC DISCONNECT(S). .DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2017 690.53 PER CODE(S):NEC 2017:690.13(8 ki ) W/4R'NII',NG OA 1048135 ��V2 �WARNtN'G DUAL POWER SUPPLY Exp. OFES,SIONP� POWER SOURCE OUTPUT CONNECNON SOURCES:UTILITY GRID 6/30/20 �- DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC �'' OVERCURRENTDEVICE SYSTEM Digitally slgn�e�d� LABEL LOCATION: LABEL LOCATION: by,,Nestor ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN L�/ ,4 APPLICABLE). SERVICE PANEL. 1'1•�u ry t0 n PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3) J 705.12(B)(2)(3)(b) Date 2025.08.13 • 7 11:17:17-04'00' O. SOLAR PV LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN SU1 RU1 SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018:1204.5.3 PHOTOVOLTAICMAXIMUM. .P •PERATING CURRENT: 32 AMPS SOLAR PV SYSTEM EQUIPPED 00825-ME WITH RAPID SHUTDOWN 1)2 CRNTInOUEROCN RO 0 WEBTBUPY NY tl590 PHONE B055405nBi • ` •' • •1 FAX 045 260 20L2 LABEL LOCATION: CUSTOMER RESIDENCE: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. DONALD DEERKOSKI TURN RAPID SHUTDOWN 2055 GRAND AVE,MATTITUCK, PER CODE(S):NEC 2017:690.54 NY,USA 11952 SWITCH TO THE"OFF" SOLAR 4 • . • ELEOTRIC Rv TEL.(407)221-0479 POSITION TO SHUT DOWN PV PANELS APN:1000-107-00-OB-00-005-000 POWER PROJECT NUMBER: LABEL LOCATION: SYSTEM AND REDUCE SHOCK 216R-055DEER INTERIOR AND EXTERIOR DC CONDUIT EVERY IO FT,AT EACH TURN,ABOVE AND BELOW PENETRATIONS, HAZARD DLf1R IU'1 D IN THE ARMY. DESIGNER: (415)580-6920 ex3 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. LE MCDOWELL SERRANO PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), IFC 2012:605.11.1.4 LABEL LOCATION: SHEET ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE 1 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 8/12/2025 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 F NE BUILDING SUPPLIED BY UTILITY c- oo Hop�yo GRID AND PHOTOVOLTAIC * _�`'� SYSTEM W 108135 V Exp.oA�OFfSSIONP�� 6/30/202 g' Digitally si'gnedl � J PV SYSTEM DISCONNECT b N esto r Houghton ZO55 GRAND AVE,-TITUCK, Y.USA 11952 ']Date. LABEL LOCATION: 2025.08.1 3 POINT OF INTERCONNECTION (PER CODE:NEC 2017690.56(B),705.10.225.37,230.2(E)) 11:17:26 -04'00' SUlRLn 00825-M E 177 CAN]uGUE ROC[ROAD,-BURY,NY 11590 -E9fb54G5AB] FA%BCS 3603B32 CUSTOMER RESIDENCE: DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, NY,USA 11952 TEL.(407)221-0479 APN:100 D-107-00-08-00-005-000 PROJECT NUMBER: 216R-055DEER DESIGNER: (415)680-6920 ex3 MCDOWELLSERRANO SHEET SIGNAGE 2 REV:A 8/12/2025 PAGE PV-5.1 ;ac rc 0 ' PV -/> S I R I U S powered by ¢liN ELNSM54M-HC Series MB B HC MONOCRYSTALLINE P V MODULE MSIMILEUINUM 400 - 415W Sirius redefined the high-efficiency' ■ ' Monofacial Black Series module; 1 82mm silicon wafers with multi-busbar and half-cut cell technologies. Sirius panel combined creative technology effectively and extremely improve •• d power QUALITY SYSTEM KEY FEATURES ISO ISO 9001:2015,ISO 14001:2015,ISO 45001:2018, ISO 27001:2013,ISO 10002:2004 Less mismatch to get more power PRODUCT CERTIFICATION o..as / c 5�16 LSE ©FSEC w CrYCLE` Our preselected technology features a zero gap cell layout,resulting in module TS EN 61215,TS EN 61730 efficiency up to 21.25% IEC 61215,IEC 61730,IEC 62804(PID FREE) UL 61730-1,UL 61730-2 Less power loss by minimizing the WARRANTY shading impact uP to F25 Guarantee On 25 Linear Power Product Output Warranty Competitive low light performance 99.1 96.2% Additional Value from Linear Warranty '4 93.95% � .7 1s., „_. ' 91.7% Ideal choice for rooftop and commercial 90 ) e9.as% scale projects by reduced BOS and improve j � n c� , e71% ROL �{ c�. In stringent environment condition '/ 0 5 �.10 15 20 25 • Sand,acid,salt and hail stones, -or 7ERC a,enaryrzc3i F;oai s70CULc5:less[nan 2 0%n:he firs[year,;nereaf;er Bess man O DS%oeryear,ending • 5400pa wind load and S400pa snow wlti no less man 57.2%h[he251^year after ne Warranty 5[art Cate the acual oucxt Dower s calc laced as follows load. accual Power Oucocc('year=')>-Nominal Dower•(l-2%) PID FREE actual PDwer O UCDU[(Year=N,25NI525)a Nominal Power'('42%-0.45%•(N-');) PV„ -/> S I R I U powered by ¢LiN ELNSM54M-HC Series ELECTRICAL SPECIFICATIONS Module Type ELNSM54M- ELNSM54M- ELNSM54M- ELNSM54M- HC-400W HC-405W HC-410W HC-415W __._.. ..�._..__...._.._._.. STC NOCT STC NOCT ( STC NOCT STC NOCT ----- ---------^--- -. - MaximumPower 400 301 405 304 410 308 41S 311 __,.,,.,_,__..,,__�._.__._,.,., m (Pmax) Open Circuit 37.12 34.64 37.22 34.73 37.32 34.81 37.42 34.90 --_._...__...._... __...._..,_ Voltage(Voc) Short Circuit 13.60 10.99 13.70 11.07 13.80 11.15 13.90 11.23 Current(Isc) Maximum Power 30.81 28.82 30.93 28.91 31.05 29.05 31.16 29.19' Voltage(Vmp) -___..___......._...___._.....__� Maximum Power ------------=----•-- Current(Imp) 12.99 10.44 13.10 10.51 13.21 10.59 13.32 10.66 -"- -- '---' - ' - - Module Efficiency ` 20.48 20.74 21.00 I 21.25 " STC(%) _ � - - _ Power Tolerance (0+4,99 W) Pmax Temperature' -0.34%/°C s Coefficients ---- Voc Temperature Coefficient -0.26%/'C Isc Temperature +0.05%/°C •� - " ro ro Coefficient - *Measurement Tolerance+/-3% ` STC.-Irradiance 1000W/m2,module temperature 25'C,AM=1.5 NOCT.-Irradiance 800W/m2,Ambient Temperature 20'C,AM=1.5,Wind Speed lm/s 33 APPLICATION • . • Maximum System Voltage 1 S_OOVDC os z Maximum Series Fuse Rating 25A Operating Temperature -40-+85'C Nominal Operating Cell Temperature 45±2'C Mechanical Load Front Side 540OPa/Rear Side 540OPa SPECIFICATIONSMECHANICAL External Dimension 1722 x 1134 x 35 mm (67.80"x 44.65"x 1.38") Weight 21.Skg±O.Skg (47.40lbs±1.10lbs) Solar Cells PERC Mono Crystalline(108 pcs) ^y _Glass 3.2 mm AR coating tempered glass Frame Black anodized aluminium alloy Junction Box IP68,3 diodes Output Cables* 4.0 mm',13SO mm(+)/1350 mm(-)or Customized Length s' ' Connector ;MC4 compatible or staubli(should be specified at the time of order) *Output cable lengths should be specirted at the time of order. PACKING CONFIGURATION 1722x 1134 x 35 mm Container 53 Pt Truck Pieces per Pallet 31 Pallets per Container 29 Pieces per Container 899 1, Assembled in USA 'I I lk:iM1'S >'a ;s r ✓ '_ l°u„s p'V c`o>r1i, M. solar=@ " • Single Phase Inverter with HD-Wave Technology ■ for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/ SE760OH-US J SE10000H-US/SE1140OH-US ® solar-..: i solar•- rF h.�werfe� lea Wart _ F ;" J s' t I Optimized installation with HD-Wa.ve techno logy ology Soe"'ciT'cal.`/'de_S geed t.o,rvorx`ir-i pow ' i e-cord oreakin5,., c er cy: , f A, �::i red voftage inverter for'onge"st;ngs A me 'ated arc fault protection 3nd'ra:pid sh-rtrdo,.vn for NEC 2014?nd2017, :oer article 590 =1 and 690.1) - A1741 SA re,tiff d', for C-P C'Rul e 21 grid como'i-ance xtremelyymaii — High reiiaoility witnout any electrolyte cacacitors — 3u:11t in modu!e-1 eve l'monitor-ng D — Outdoor and indoor installaklon Wave — Oot?onal: Revenue trade data,ANSI C 12.20 Class 0.5 1'0.5' accuracy) i w1.1Jw.S013redge.uS solar=eeSingle Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US ! SE500OH-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE1140OH-US SE3000H-US SE380OH-US SE500011-US SE6000H-US J SE760OH-US I SE10000H-US SE1140OH-US OUTPUT _ -- — — 3800 @ 240V 6000 @ 240V —T Rated AC Power Output 3000 -000 7600 10000 11400 VA ...............................3300 @ 208V....... 3800 @ 240V 6000 @ 247V Max.AC Power Output 3000 5000 7600 1 10000 11400 VA ...._.„ 33Q0 @ 208V_: 5000 AC Output Voltage Min:-iNom.-PAax. ✓ ✓ Vac ........................................................ ..:............._ ................!. AC Output Voltage IMin:Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓20. Vac 7). .........-. ........... ............................................ ... .........1......... AC Frequency(Nominal) 59.3-60-50.5 Hz j Maximum Continuous Output Current 208V 16 24 A ...... ......' ... ..... .............._.. :. Maximum Cont nuous Output Current I @240V 12.5 16 1 21 25 i 32 42 47.5 1 A ............................................................ ................:............................................................................................ . GFDI Threshold 1 A Utility Mo ..nit.......oring.,.I.s[a n*d i. ng...P r..ote.....ction....,... ....... ................................. Y.........a,..................... ..................................i........ Country Configurable Thresholds INPUT ---- Maximum DC Power @240V 4650 5900 7750 I 9300 11800 15500 17650 bV .................... .......... ... ... ........-. ....,..... ......... .. ..... ... Maximum DC Power @208V 5100 7750 ................................................ .. ....... ... ..:.......I.._..................... .. ....... .. Transformer-less,Ungrounded Yes _...... ...................................................................... ................. .... .............................:......... . Maximum Input Voltage 480 Vdc ..... .................................... ..... .. ............. ........... ..................... ................ ................................... ....... . ..Norninal DC Input Voltage.................I..............I...........I..380 ...........I.......! ........_.... ........400 Vdc Maximum Input Current 208V - 9 13.5 ......................... ......................................... .. ... ........... ....................I........... . Maximum Input Currerit @240V 8:5 10.5 13.5 20 27 30.5 Adc Max.Input Shcrt Circuit Current 45 Adc .. .................... ....... .. ... .................. .. .... .. ........ .. ....... ... ... ... .... .. .. .. . ...... .. ..... . Reverse-Polarity Protection Yes ............ ........ ...... ... .... ... ... ... .. ... ...... .. . Ground-Fault Isolation Detection 600k_Sensitivity ..... ............... ...... .... . .. ...... ... ... .. Maximum Inverter Efficiency 99 99.2 CEC Weighted Efficiency 99 _.. ... ........... .................. ... .. ... ... ... ... ....... .........-... ... ... ... ...... ........... Nighttime Power Consumption _ _ _ <2.5 _ W ADDITIONAL FEATURES Supported Communication Interfaces RS435,Ethernet,ZigBee(optional),Cellular(optional) ...... .. ... ... .. . Rzv nue.Grad�.Data,ANSI C12.20 Optionallz Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE ,Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 ....I........ ....... . Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) ...... ........ ........ .......... ..... ..... ..... .. .... .. ... .................. . __Emissions _ FCC Part 15 Class B INSTALLATION SPECIFICATIONS T T AC Output Conduit Size/AWG Range 3/4"minimum/14-6.AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/a of S[rings/ 3/4"minimum/1-3 strings/ AWGRang?. 3/4' minimum J 1-2 strings!14-6 AWG ............... ... ... ...... .......... ...... WG ........1a5..... ........... /540 Dimensions with Safety Switch(HxbVxD) 17.7 x 14.6 x 5.8 /450 x 370 x 174 2 1.3 x 14.6 x 7.3 x370 1 in/mm x 185 >>Veight with Safety Switch 22/10.......... 25 1/11 4 26.2/11.9 38.8/17.6 Ib kg. Noise <25 <50 dBA Conlin; NaturaIConvection Natur'alconvection ...... ............. ............ ........................... ..... ........... ................................ ............................... ............ . Operating Temperature Range. ..... ..................13 to+1-10!-25 to+6013i(,40'F;-40°Copt on)l.' '-%'C Protection Rating NEMA 3R(Inverter with Safety Switch) For other regierai sarongs please cortact Seiar2oge s-ocrt RI:'tever.Le grace nverter�/N.SExsxxH-JsooCN NC2 tnl=or cower:e--ad.rg nformanon•eie,to.❑ttps//www scia-ecge ccmj sites/ce'acltj i;esj se-tempera to re-oe•aang-rote-na.odf -cC o/N:5Exxxxr-US00CNNU4 01 ;A ■ oHS Q the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks •�.•- rr, OrSubject FOR SNAPNRACK ENGINEERING TO APPLY,THE EMBEDMENT CRITERIA SHOWN HEREIN MUST BE MET(IF CRITERIA CANNOT BE MET OR SPANS ARE NOT SUFFICIENT,CONTACT DECKANCHOR SNAPNRACK FOR SUPPORT). MINIMUM DECK THICKNESS: REFER TO SNAPNRACK INSTALLATION MANUAL FOR%e"0 ALPHATRACK PLYWOOD: 15/32" HARDWARE TORQUE SPECIFICATIONS.REFER TO OSB:7/16" MANUFACTUER SPECIFICATIONS FOR OTHER FASTENER TORQUE REQUIREMENTS. ROOFING MATERIAL,TYP. ALPHATRACK ALPHATRACK BUTYL l ROOF DECKING �y ROOF DECKING ROOF DECKING AND ROOFING MATERIAL,TYP. ROOFING MATERIAL,TYP. COMPLETED DECK INSTALLATION ALPHATRACK 0516"S.S. LAG BUTYL DETAIL SCREW (DECKANCHOR SHOWN) ALPHATRACK SUlRUl 2-1/2"MIN.EMBEDMEN INTO STRUCTURAL MEMBER RAFTER TYP F�a.ne CUSTOMER RESIDENCE: A—� ###tl ROOF DECKING TEL.#### RAFTER,TYP. #### PROJECT NUMBER: ROOF DECKING AND COMPLETED RAFTER INSTALLATION STRUCTURAL ROOF MEMBER ROOFING MATERIAL,TYP. (RAFTER)TYP. DESIGNER: (415)580-6920 ex3 SHEET MOUNTING DETAIL (� Sunrun South LLC DESIGNER: M.WATKINS SCALE: NTS DRAWING NUMBER: snap U�aQ� "'�°s°'y�� DRAFTER:M.WATKINS REV:# 413/2025 Solar Mouniuig Solutions a P��„5j5��I"� Eo DATE: SNR-DC-00370 PAGE w APPROVED BY: W.AFFENTRANGER 9/16/2024 COMP SHINGLE unrun 177 Cantiague Rock Road Westbury NY 11590 LiPermits(cDsunrun.com NOV 3 '<t 2025 10/29/25 ., .ts�Lc1{re Re:2055 GRAND AVE MATTITUCK NY 11952 AS BUILT BP# 52295 DONALD DEERKOWSKI RESIDENCE PLEASE SEE ATTACHED CHANGES MADE TO PERMIT #52295 AT INSTALLATION THERE WAS A MODULE FITMENT ISSUE BECAUSE OF WAY VENT PIPE WAS IN ROOF. CHANGED LAYOUT OF MODULES IN AR-01 Thank you, Desiree Nevins Sunrun Permit Coordinator LIPERMITS@SUNRUN.COM 516-852-9348 T' October 27,2025 RE: CERTIFICATION LETTER 111 fff��X(( Project Address: DONALD DEERKOSKI RESIDENCE 2055 GRAND AVE MATTITUCK,NY,USA 11952 Design Criteria: Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS Risk Category=II -Wind Speed=128 mph, Exposure Category B, Partially/Fully Enclosed Method -Ground Snow Load=25 psf ROOF AR-01:2 x 8 @ 16"OC,Roof DL 11 psf,Roof LUSL=20 psf(Non-PV),Roof LL/SL=20 psf(PV) ROOF AR-02:2 x 8 @ 16"OC,Roof DL=11 psf,Roof LUSL=20 psf(Non-PV),Roof LL/SL=15.8 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturers specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, F�2dm i/30/202- 2-P.E OF Nerp Digitally signed 5 EY�N� O sa «�y- P� by Humphrey Kariuki m 2 Date:2025.10.27 9545� �20 ROFESSIONP�' 14:56:00-04'00' 67 5"5-Business Pare�n;ay.`)uitc 210 EIk,id;c,N1D-1075 1 (6(i7i 586-8460 1 hL,iriuI,i ftrnaiI.Corn SHEET INDEX SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION .SYSTEM SIZE:9430W DC,760OW AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE WITH 20181RC/IBC/IEBC,7-16 ASCE& PV-1.0 COVER SHEET •MODULES:(23)ELIN ENERGY(SIRIUS PV): 2018 NDS,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. ELNSM54M-HC-410 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT SE760OH-USMN •PHOTOVOLATIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER.SYSTEM •RACKING:ALPHATRACK TO FRAMING-SNR-DC-00370 COMPLIES WITH 690.41(A) PV-4.0 ELECTRICAL •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. Exp-daft •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 4/30/202 PV-5.0 SIGNAGE 1 •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. �P,�gOF NEI,I,y •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WTH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. `� �&,j KAN� O,Q PV-5.1 SIGNAGE 2 •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WTHIN ARRAY BOUNDARIES PER NEC 690.12(1). v •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.85 AMPS MODULE SHORT CIRCUIT CURRENT. •17.31 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. R 95450 �FESSIONP� Digitally signed by Humphrey Kariuki Date: 2025.10.27 14:56:28 -04'00' suiRul 00825-ME ABBREVIATIONSVICINITY MAP177 NTiAGUEROCK RO D,WESTBURY,NY 11590 A AMPERE FAX B<SIEB 2013 AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CUSTOMER RESIDENCE:s°r DONALD DEERKOSKI AZIM AZIMUTH 2055 GRAND AVE,MATTITUCK, COMP COMPOSITION - NY,USA 11952 DC DIRECTCURRENT , TEL.(407)221-0479 (E) EXISTING �y,d _ APN:1000-107-00-08-00-005-000 ESS ENERGY STORAGE SYSTEM PROJECT NUMBER: MSP MAIN SERVICE PANEL V 216R-055DEER (N) NEW • � .xa, -..;: DESIGNER: (416)580-6920 ex3 PRE-FAB PRE-FABRICATED ~ �'W. MCDOWELL SERRANO PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC _ •�' 3 SHEET RSD RAPID SHUTDOWN DEVICE REV NAME DATE COMMENTS COVER SHEET TL TRANSFORMERLES$ 0 ` REV:B 10/27/2025 0 PAGE V VOLTS a°'°•° w wATrs - `� °,•a. er PV-1.0 SITE PLAN-SCALE=3/32"=V-0" SITE PLAN DETAIL-SCALE=1/64"=V-0" ® (N)ARRAY AR-02 O� (E)STAIRS y ROOF PATHWAYS O7L (3'TYP) � o e:p.d.w also/zDz��,�E OF NEI,),y (E)RESIDENCE E DETACHED �� - ( ) \\� GARAGE _ - ' w 95450 OFESSIOV4 (E)DRIVEWAY Digitally signed by Hamphrey--.` Kariuki F pg Ss MP [] Date: 2025.10.27 H SE '""1 14:56:49 -04'00' ROOF PATHWAYS ���� (3'TYP) FIRE SETBACKS (18"TYP) (N)ARRAY AR-01 00825-M E 177—TIAOUE—ROAD,—BURY.NY 115M PHONE6o55m.5<E7 PA%B45 E65 i0R NOTES: CUSTOMER RESIDENCE: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, ARRAY DETAILS: NY,USA 11952 • TOTAL ROOF SURFACE AREA:2980 SQFT. • TOTAL PV ARRAY AREA:483.5 SQ FT. ARRAY TRUE MAG PV AREA TEL.(407)221-0479 • PERCENTAGE PV COVERAGE: PITCH AZIM AZIM (SQFT) qPN:1000-107-09-06-00-005-000 (TOTAL PV ARRAY AREAlTOTAL ROOF SURFACE NOTES: AR-01 10° 247°1 238° 1 315.34 PROJECT NUMBER: ES OR FENCES AREA)`100=16.2% NO GAT 216R-055DEER PRESENT ON SITE AR-02 21° 67° 58° 168.18 LEGEND SCALE:NTS AC COMMUNICATION SOLAR DESIGNER: (415)580-6920 ex3 NOTE:PN(DTPE ALL WISE IN PLAN END SM SUNRUN METER AC DISCONNECT(S) O MD MICROGRID INTERIOR EQUIPMENT MODULES WILL APPEAR IN SITE PLAN H11 WIRES INTERCONNECT DEVICE L J SHOWN AS DASHED MCDOWELL SERRANO DC GROUNDING + - SE SERVICE ENTRANCE PM DEDICATED PV METER DC DISCONNEC1=1T(S) 1;1 ELECTRODE MA METER ADAPTER -�F BATTERY SHEET ENERGY STORAGE SITE PLAN MP MAIN PANEL SEM SOLAREDGE METER INV INVERTER(S) GP GENERATION PANEL BI BACKUP INTERFACE SYSTEM(ESS) SNR MOUNT REV:B 10/27/2025 SP SUB-PANEL .ACREL METER LC PV LOAD CENTER CB IQ COMBINER BOX BP BACKUP LOADS PANEL SNR MOUNT 8 SKIRT PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF g yP Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF AR-01 COMP SHINGLE-- 2-Story 2X8 RAFTERS 13'-1" 16" ALPHATRACK TO FRAMING-SNR-DC-00370 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED WIND SPEED: ALPHATRACK 128 MPH 3-SEC GUST. COMP SHINGLE- FASTENERS: AR-02 ALPHATRACK 1-Story 2X8 RAFTERS 12'-5" 16" ALPHATRACK.TO FRAMING-SNR-DC-00370 5'-0" 2'-," 4'-0" Z-O" STAGGERED (1)5/16"DIA S.S.LAG SCREW:2.5' MIN EMBEDMENT INTO FRAMING D1-AR-01-SCALE:3/16"=V-0" Exp.da7° AZIM:247° 4130120 OF NE),y PITCH:10° Kg7yq J m = d' a. 1 2 j I I 96450r ¢-4-TYP-¢ RopEssloNP�' Digitally signed 11'A" / B EI R 9 e B by Humphrey' Kariuki Date: 2025.10.27 14:57:05 —04'00' —k— D2- ' -SCALE:3/16"=1'-0" �� AZIM:67 67 PITCH:21° mn V-7� / 00825-M E W 9F EROCKRW.D.K BURV,NTtt590 P110NE86554 87 F0.0 2.2- CUSTOMER RESIDENCE: DONALD DEERKOSKI 15'-4"TYP-¢ 2055 GRAND AVE,MATTITUCK, 13'-3" NY,USA 11952 / TEL.(407)221-0479 APN:1000-107-00-08-00-005-000 STRUCTURAL NOTES: j INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL PROJECT NUMBER: 4'TY P STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ 216R-055DEER �/ t INSTALLATION. DESIGNER: (415)580-6920 ex3 • F ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS MCDOWELL SERRANO 2'-6" NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" SHEET i BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE LAYOUT { 16'-8" 15'-1" 2'1"{- REDUCED BY 50%. ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF REV:B 10/27/2025 ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: 98298224 OACCOUNT#: UTILITY 9625516451 GRID SUPPLY SIDE TAP EXISTING GENERATOR NOTE:TOTAL PV BACKFEED=40A *y�=�pR HO#��0�� USED FOR INTERCONNECTION z EXISTING OPEN CALCULATIONS TRANSITION GEN - W TRANSFER SWITCH 4 f08135 V Op �a � (N)LOCKABLE �FESSIONP� C 1 EXISTING 150A 6/3012 BLADE TYPE 0 MAIN BREAKER FUSEDTY SOLAREDGETECHNOLOGIES: Digitally signed DISCONNECT SE7600H-USMN 9 Y g 1 7600 WATT INVERTER JUNCTION BOX PV MODULES 3 2 OR EQUIVALENT 1 ELIN ENERGY(SIRIUS PV): by NeStOf EXISTING200A 410 I IOu htOn �� MAIN PANEL o ✓ i + �// (23)MODULES g :- OPTIMIZERS WIRED IN: Date: 2025.1 0.27 FACILITY 40A FUSES (1)SERIES OF(12)OPTIMIZERS LOADS -Ga UND SQUARE D LOAD RATED DC DISCONNECT (1)SERIES OF(11)OPTIMIZERS 14:58:51 -04'00' D222NRB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A COMPLIANT U650 120/240VAC sulnul CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 00825-ME 177 CA—UE ROCI(ROnD,—BURY,NY11- 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER RRO-2 5i05<B7 F,�a«�.zan 2 1" PVC OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE 1 10 AWG THHN/THWN-2 DONAL DE RESIDENCE: ( ) DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, 3 1" PVC OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHNfTHWN-2 NY,USA11952 4 1" PVC OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 TEL.(407)221-0479 APN:1000-107-00-08-00-005-000 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 U660 OPTIMIZER CHARACTERISTICS: 216R-055DEER MODULE CHARACTERISTICS SYSTEM SIZE: 9430 W MIN INPUT VOLTAGE: 8 VDC 415 5 SYSTEM OPEN CIRCUIT VOLTAGE: 12 V MAX INPUT VOLTAGE: 60 VDC DESIGNER: ( ) 80-6920 ex3 ELIN ENERGY(SIRIUS PV): 410 W SYSTEM OPERATING VOLTAGE: 380 V MAX INPUT ISC: 15 ADC MCDOWELL SERRANO ELNSM54M-HC-410 MAX ALLOWABLE DC VOLTAGE: 480 V MAX OUTPUT CURRENT: 15 ADC SHEET OPEN CIRCUIT VOLTAGE 37.32 V SYSTEM OPERATING CURRENT: 24.82 A SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL MAX POWER VOLTAGE 31.05 V SHORT CIRCUIT CURRENT 13.85 A REV:B 1 012 712 02 5 PAGE PV-4.0 INVERTER 1 �W�RNING /►ylp /�► NOTES SIGNSAAND AND T � WMfIIN'lll PHOTOVOLTAICD D • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM MAXIMUM SYSTEMVOLTAGE: 480 • IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL •SIGNS AND LABELS SHALLADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM CIRCUIT CURRENT: 30 ADC WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD DO NOT ADD LOADS •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN RATEDMAX OUTPUT OF THE CHARGE METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITIONN LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT• '• '•'• •• • • N/A •• PHOTOVOLTAIC AC COMBINER(IF INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY EOF Nf LABEL LOCATION: PER CODE(S):NEC 201 7:705.12(B)(2)(3)(1) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. •`Q` �' INVERTER(S),AC/DC DISCONNECT(S), INVERTER(S),OC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2017690.53 PER CODE(S):NEC 2017:690A 3(B) WAN,G INAR'NING �. DUAL POWER SUPPLY 108135 �1�\ POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID Exp.. A�FfSSIONp�'� DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC 6/30/20 OVERCURRENT DEVICE SYSTEM Digitally signed LABEL LOCATION: LABEL LOCATION: ,r _ ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN by N'esto r APPLICABLE). SERVICE PANEL. PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3) 705.12(B)(2)(3)(b) Houghton Date: 2025.10.27 o 1 �• 14:59:08-04'00' O. SOLAR PV LABEL LOCATION: INSTALLED WITHIN RAPID SHUT DOWN ���� SWITCH PER CODE(S): N NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018:1204.5.3 •.•OP PERATING •_.CO SOLAR PV SYSTEM EQUIPPED 00825-ME MAXIMUM NOMINAL OPERATING AC VOLTAGE: 240 VACWITH RAPID SHUTDOWN R7CA IaGUERGGrt RGAp WESTBURY NY 11590 P�eaa�=m�� LABEL LOCATION: CUSTOMER RESIDENCE: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. DONALD DEERKOSKI TURN RAPID SHUTDOWN 2055 GRAND AVE,MATTITUCK, PER CODE(S):NEC 2017:690.54 NY,USA 11952 SWITCH TO THE"OFF SOLAR • • • ELECTRIC PV TEL.(407)221-0479 POSITION TO SHUT DOWN PV PPNELS • • APN:1000-1o7-oo-aa-oo-ooa000 PROJECT NUMBER: LABEL LOCATION: SYSTEM �AND REDUCE SHOCK 216R-055DEER INTERIOR AND EXTERIOR OC CONDUIT EVERY 10 FT, AT EACH URN,ABOVE AND BELOW P NETRAT ONS, HAZARD IN THE ARRAY. DESIGNER: (415)580-6920 ex3 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. LLI MCDOWELL SERRANO PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), IFC 2012:605.11.1.4 LABEL LOCATION: SHEET ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE 1 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:B 10/27/2025 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC SYSTEM tOF Nfk,Y DR HO(/�rOp� 108135 6l30/20 PV SYSTEM DISCONNECT Digitally signed- by Nestor Houghton 2055 GRAND AVE,MP.TTITUCK,NY,USA 11952 ' LABEL LOCATION: Date: 2025.10.27 POINT OF INTERCONNECTION (PER CODE:NEC 2017 690.56(B),705.10.225.37,230.2(E)) 14:5 9:27-041001 sulnul 00825-M E 177OANTiAGNER=ROAD.-TBURY.NY 1150 PHON-5405487 A%9 45 2 68 2022 CUSTOMER RESIDENCE: DONALD DEERKOSKI 2055 GRAND AVE,MATTITUCK, NY,USA 11952 TEL.(407)221-0479 APN:1000-107-00-08-00-005-000 PROJECT NUMBER: 216R-055DEER DESIGNER: (415)580-6920 eXJ MCDOWELL SERRANO SHEET SIGNAGE 2 REV:B 10/27/2025 PAGE PV-5.1 PV> S I R I U S powered by ¢LiN ELN5M54M-HC Series MB B HC MONOCRYSTALLINE P V MODULE 95EMBLED IN USA 400 -415W FMenofaclait Black Series redefined,Sirius module 182mm silicon wafers with mutti-busbar and ll - Sirius panel combined creative technology effectively nd extremely 1 improve module • •• • -• QUALITY SYSTEM KEY FEATURES ""'N ISO 9001:2015,ISO 14001:2015,ISO 45001:2018, _ O ISO 27001:2013,ISO 10002:2004 Less mismatch to get more power PRODUCT CERTIFICATION ^� IlOV c��us TSE 'Pil° Qr�Ec. iw. PVCYCLE Q 1 ) Our preselected technology Features a v r� zero gap cell layout,resulting in module TS EN 61215,TS EN 61730 efficiency up to 21.25% IEC 6121 S,IEC 61730,IEC 62804(PID FREE) UL 61730-1,UL 61730-2 Less power loss by minimizing the WARRANTY shading impact uPt° 25 Guarantee On 25 Linear Power Product \7_Y Output Warranty Competitive low light performance Additional Value from Linear Warranty ".SZ_, 93.95% ,. �.., 91.7% Ideal choice for rooftopd commercial 90° 89a5% an commerc 11 ] 87.2% scale projects by reduced BOS and improve,_ ROI• R ;. a In stringent environment condition y�o°" fi ,o 15 20 25 • Sand,acid,salt and hail stones, 5400pa wind load and 5400pa snow `cv,cnocFs: racai wceu a<_ e s,an: ;-ae ;,__ :,,;r. :;,-a.°.s^;—year_•°,-.5 • ° 0,.o Bess:-an d72%-:he 2r`ye:r,f:a-:,-e aranry Star lace.-ne3—al ;30—15;alc',.la—a,r�,C., load. ._. . .o,,-al 2%) • PID FREE ncuancw=rOu L:,' >,-v,%s,Js25,zvcnnaIt -• 2%-0<5%-'n�)j) — - _ ua SIRIUS 'P� powered by ¢LiN ELNSM54M-HC Series ELECTRICAL SPECIFICATIONS ELNSM54M- ELNSM54M- ELNSM54M- ELNSM54M- Module Type HC-40OW HC-405W HC-41OW HC-415W - STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power 400 301 405 304 410 308 415 311 h (Pmax) Open Circuit 37.12 34.64 37.22 34.73 37.32 34.81 37.42 34.90 Voltage(Voc) a Short Circuit 13.60 10.99 13.70 11.07 13.80 11.15 13.90 11.23 Current(Isc) Maximum Power 30.81 28.82 30.93 28.91 31.05 29.05 31.16 29.19 Voltage(Vmp) Maximum Power - Current(Imp) 12.99 10.44 13.10 10.51 13.21 10.59 13.32 10.66 Module Efficiency 20.48 20.74 21.00 21.25 STC(%) I UJ,I Power Tolerance (0+4,99 W) (W) Pmax Temperature -0.34%/°C Coefficient .w „_ •- -. Voc Temperature -0.26%/°C Coefficient Isc Temperature +0.05%/"C - ro ro Coefficient *Measurement Tolerance+/-3% STC:Irradiance 1000W/m2,module temperature 25°C,AM=1.5 NOCT.-Irradiance 800W/m2,Ambient Temperature 20°C,AM=1.5,Wind Speed im/s ss APPLICATION • • Maximum System Voltage 1500VDC Ci:xJ Maximum Series Fuse Rating 25A III,: Operating Temperature -40--+85°C Nominal Operating Cell Temperature 45±2°C Mechanical Load Front Side 540OPa/Rear Side 540OPa SPECIFICATIONSMECHANICAL External Dimension 1722 x 1134 x 35 mm (67.80"x 44.65"x 1.38") Weight 21.5 kg±0.5 kg (47.40 lbs±1.10 lbs) Solar Cells PERC Mono Crystalline(108 pcs) Glass 3.2 mm AR coating tempered glass Frame Black anodized aluminium alloy Junction Box IP68,3 diodes Output Cables* 4.0 mm',1350 mm(+)/1350 mm(-)or Customized Length Connector MC4 compatible or staubli(should be specified at the time of order) *Output cable lengths should be specified at the time of order. PACKING CONFIGURATION 1722x 1134 x 35 mm Container 53 Ft Truck Pieces per Pallet 31 Pallets per Container 29 Pieces per Container 899 s Assembled in USA www.siriuspv.com solar - . . • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/ SE380OH-US/ SE500OH-US/ SE6000H-US/ SE760OH-US/ SE10000H-US/ SE1140OH-US solar-..: solar==[' r� �pv orig� - m.12_25 ,eats i wartanly a •�a�fana�•, '8 & Optimized installation with HD- Nave technology S-e( ..'] !�J _!.j�, _.Cal C) f�/'J��<�.V,'--I ��`.Vt, Aff nte-'areul 3'� -a,.iit orQLeClIoin ?n'u -ao;d' sr,utdawrn `Or \l_C 20"_4 3nd 2'-7_ _ 3, 5ill.;. 0 d J90, -- %d'_ fir- :2r`"ed, :o-CP'�l. 3,li1Y Pl'tn0'_IL..3nv,.. ..__ C)I',i _;1:/dC4Ln — 3�1i'� n n,c�du���-:eve: -.•.on:to��� Illllilllli��� O,;L cur and odour m;r,�;aIL o wave Cot,onai: nevenUe;ride data,AN.51 C:12.20 Class 0.5 lG.5,:,o accuracy v,.,"V.sola,, ,,_.u, solar=a@ Single Phase Inverter with HD-Wave Technology for North America SE3000H-US; SE380OH-US ;' SE5000H-US / SE6000H-US/ SE760OH-US/ SE10000H-US / SE1140OH-US j SE3000H_US�SE3800H US j SESOOOH US SE6000H US�SE7600H U5� SE10000H-U5� SE1140OH-US OUTPUT Rated AC Power Cutout 3000 3800 @ 240V 500E 6000�240`•/ 7600 10000 L1400 V'/1 3300•@ 208V 5000 @ 208V 3800 @ 240V 6000 @ 240:' N13x.AC Poaver Output 3000 5000 75GG 10000 11400 VA 3s00 @ 203V SGCG:d 20gy AC Cubut Voltage Pdin.-Npm.-�bla:c. ✓ ✓ Vac ;183 ?C8 2291 AC.Cutput'voitage Nlin.Nom.-:Vlax. 21 1 2.10-264) ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac A.0 F-requency(Nominal) SP.3-60-6C.5'1 H Nlaximum Continuous Output Currer,t 208V - 1E 2=I - A Maximum✓pnt..n1JOL5 CULPL t Current 2.5 1-6 21 25 3' t' !?.S ,02"tOV Gr Dl Tiueshoid A utlity'Vloritoring, slanding Protectton, e'L0 ntQ Connigurablp T-hr s^oids INPUT ---- - ------_..- -__.._ -.------------- Llax:mum DC Power @2,10V 110'50 5900 77.0 3300 11800 15500 17550 W Vl3ximum DC?ower @208V 3.00 7750 - Transformer-less,Ungrounded Yes tilaximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V 9 5 .... ... ......... ... ... .. .... . .... .. .., Maximurn Input;Current @210V 3.5 L0.5 13.5 16.5 20 27 30.5 Aac %13x.Input Short Circuit Current IF Adc Reverse-Polarity Protecton Yes Ground-Fauit:spl2don Detection 5C0k,-Sens;dv4y P,laximum Inverter Efiiciencv 99 99.2 CEC weighted E.Tciencv 99 ,Nighttime Power Consumpt on <2.5 \IV ADDITIONAL FEATURES Sucparted Communication inter aces R5435,Ethernet,Z;Vee(optional),Cailular!DoHonai) ;avenue Grade Data,AN51 Ci2.20 Optonai!z- Rapid Shutdown-NEC 20'-1 arc 2:., ; \uLO RIaCC Zapi;;Sh litdCwn :pC^.?\G Gfid.'ili Cu rinP-C; 690.12 _ STANDARD COMPLIANCE Safety UL1741,UL1741 5A,UL16998,CSA C22.2,Canadian APCi according to T.LL.NA-07 Grid Connection Standards iEEE1547.Ruie 21,Rule 1dfHl; Emissirns FCC Part 15 Class B INSTALLATION SPECIFICATIONS _ AC Output Conduit Size/AWG3 Range —- ----- - -3/4"minimum% ,1-6 r\wG --3/ minimum 114-a AwG -- - DC input Conduit Size!='of 51;ings( 3Pl"minim um;`1-3 strings A'•,!C Range3/»"minimum r t-2 strings j 1d-5,4tVG 1::;_5 A+•,VG Dimensions with Safety Switch(HxVV:<D) 17.7 x 14.E x 6.8 j 15+:x 370 x 174 21.3x14.6x7.3/340x370x 1-85 n;'mrn Velo'rt with Safety Switch 2' 10 25. 1 1 4 26.2/11 9 38.3,1 1,76 i�, kg Noise <25 <50 c BA Cooing NaturalCorvecdon Naturalcorvectlor Operating Temperature Range 13 to--4C/-25 to+60(11(-a0 1-40'C ootion)I.1 _ otec Lion Rating NEN1.4 R(inverts with Safety Swib.h? 9T9,�ogicra ae^..^gs o ease mr:ac.-olar-Cga s,.000r. ''Rever_egrace rve•ter3/`1 3Exxexn_SOCC»\Q -e-eo-me•oe--a::rg ;s-a.^,on-e'^•to �_�s�Lmwwscla'ecge ce.-+.js"test_a=a.:a/`des/se-ce^oerao_re-�e•arrs+ote-r a ec' 4„ve•so.-'4 i.cxxx�-:SC.CV`._ RoHS OSolarEdge Technologies, the SolarEdge logo,OPTIMIZED BY SOLAREDGE Technologies,are trademarks or registered trademarks of SolarEdge Date: are trademarks of their respective owners. FOR SNAPNRACK ENGINEERING TO APPLY,THE EMBEDMENT CRITERIA SHOWN HEREIN MUST BE MET(IF CRITERIA CANNOT BE MET OR SPANS ARE NOT SUFFICIENT,CONTACT DECKANCHOR SNAPNRACK FOR SUPPORT). MINIMUM DECK THICKNESS: REFER TO SNAPNRACK INSTALLATION MANUAL FOR hi6"0 ALPHATRACK PLYWOOD: 15/32" HARDWARE TORQUE SPECIFICATIONS.REFER TO OSB:7/16" MANUFACTUER SPECIFICATIONS FOR OTHER FASTENER TORQUE REQUIREMENTS. ROOFING MATERIAL,TYP. ALPHATRACK ALPHATRACK F' BUTYL ROOF DECKING ROOF DECKING ROOF DECKING AND ROOFING MATERIAL,TYP. ROOFING MATERIAL,TYP. COMPLETED DECK INSTALLATION ALPHATRACK 05116"S.S. LAG BUTYL DETAIL SCREW (DECKANCHOR SHOWN) ALPHATRACK sLnnul 2-1/2"MIN.EMBEDME #### INTO STRUCTURAL MEMBER RAFTER TYP CUSTOMER RESIDENCE: ROOF DECKING TEL.#### RAFTER,TYP. #### PROJECT NUMBER: ROOF DECKING AND COMPLETED RAFTER INSTALLATION #### STRUCTURAL ROOF MEMBER ROOFING MATERIAL,TYP. (RAFTER)TYP. DESIGNER: (415)580-6920 ex3 SHEET /\�\ �� Sunrun South LLC DESIGNER: M.WATKINS SCALE: DRAWING NUMBER: MOUNTING DETAIL sna�� QC�Q�i" E � s�� r .,z�: ��. NTS REV:# 4/3/2025 DRAFTER:M.WATKINS SNR DC 00370 soia�I�Ar,unling Soi;:u,ns �,o ow r DATE: 9/16/2024 PAGECOMP SHINGLE APPROVED BY: W.AFFENTRANGER