Loading...
HomeMy WebLinkAbout52511-Z X�oF souTyO`° Town of Southold * * P.O. Box 1179 Boa' 53095 Main Rd ►an Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46728 Date: 12/11/2025 THIS CERTIFIES that the building AS BUILT HVAC Location of Property: 4040 Bay Shore Rd Greenvort, NY 11944 See/Block/Lot: 53.-6-27.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/27/2025 Pursuant to which Building Permit No. 52511 and dated: 12/04/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" mini-split unit as applied for. The certificate is issued to: Thomas Rondi ,Ann Rondi Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 25-858 10/17/2025 PLUMBERS CERTIFICATION: Aut o e Signature ofsotf TOWN OF SOUTHOLD BUILDING DEPARTMENT ' 4 SOUTHOLD, NY 0OUNTV-4 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52511 Date: 12/04/2025 Permission is hereby granted to: Thomas W Rondi 4040 Bay Shore Rd Greenport, NY 11944 To: legalize "as built" mini-split unit as applied for with flood permit. Premises Located at: 4040 Bay Shore Rd, Greenport, NY 11944 SCTM#53.-6-27.1 Pursuant to application dated 10/27/2025 and approved by the Building Inspector. To expire on 12/04/2027. Contractors: Required Inspections: Fees: As Built Alteration $500.00 CO-RESIDENTIAL $100.00 Flood Permit $150.00 Total S70.00 Ntui ding Inspector East End Inspection Agency, LLC P.O. Box 35 East Quogue, New York, 11942 EEI (631) 594-2272 Fax(631) 594-2598 East End Inspection Agency office@eastendinspectionagency.com CERTIFICATE OF ELECTRICAL COMPLIANCE This Certificate of Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant and not after the final inspection date listed. Owner: Thomas Rondi Date: October 17, 2025 Address: 4040 Bay Shore Rd Certificate No: 25-858 Greenport, NY 11944 Location of Property Inspected 4040 Bay Shore Rd Greenport, New York STCM Dist 1000 Section: 53 Block: 6 Lot: 27.1 Permit Number [X]Addition [X] Residential [X]AC Unit AC Units- 1 20 Ductless AC 1-condenser unit Date of Roughing Inspection: Date of Final Inspection: 10/9/2025 The electrical work and /or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements at the time of inspection. Installer: Homeowner License Number: N/A Electrical Inspector: _..� Edward Seltenreich �aq SOUTyo # TOWN OF.SOUTHOLD BUILDING DEPT. °yMum 631-765-1802 ss INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAUL G [ ] FRAMING /STRAPPING [ ] FINAL 1�'11f✓1 ll // ' "". [ . ] FIREPLACE & CHIMNEY [ ] FIRE.SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] .FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE l INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) — -"------- --.— - � a ------------------------------------- -- ----- ---- - - - ---- VJoo FOUNDATION (2ND) _ z O ROUGH FRAMING& PLUMBING r INSULATION PER N. Y. — - STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 2 - S- -Z� _���+- Sa as C fi �L ✓e G- l l / �o C1r i L CQ� LE l h - l.0 �1 2� 0 Sz b M ----- •-- to r� TOWN OF SOUTHOLD—BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only i PERMIT NO. Building Inspector: 0 CT 2 7 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an 71 "?" Owner's Authorization form(Page 2)shall be completed. n Date: OWNER(S)OF PROPERTY: Name:Thomas & AnnMarie Rondi SCTM#1000- 5�5 2-7 • ) Project Address:4040 Bay Shore Road Greenport NY 11944 Phone#:6313609850 Email:tomrondi@gmail.com Mailing Address:4040 Bay Shore Road, Greenport NY 11944 CONTACT PERSON: Name:Thomas Rondi Mailing Address:4040 Bay Shore Road, Greenport, NY 11944 Phone#:6313609850 Email:tomrondi@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Myself Thomas Rondi & son-in-law Mathew Fragano Mailing Address:404 Bay Shore Road Greenport NY 11944 Phone#:6313609850 Email:tomrondi@gmail.com CONTRACTOR INFORMATION: Name:Thomas W Rondi Mailing Address:Myself Thomas Rondi & son-in-law Mathew Fragano Phone#:6313609850 1Email:tomrondi@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: []Other Mini Split Unit A/C $5400.00 Will the lot be re-graded? ❑Yes ANo Will excess fill be removed from premises? ❑Yes ©No 1 PROPERTY INFORMATION Existing use of property: Mounted to Foundation Intended use of property:None Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes �No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Thomas W. Rondi ❑Authorized Agent BOWner Signature of Applicant: IE D.BUNCpate: 9/9/25 Notary Public,State of New York No.01 BU6185050 STATE OF NEW YORK) Qualified In Suffolk County SS: Commission Explres.April 14,2 COUNTY OF Suffolk ) Thomas Rondi being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Thomas Rondi & Matthew Fragano (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this c ay of 20_aC M� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Thomas Rondi 4040 Bay Shore Road, Greenport NY 11944 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 sufFoc�r TOWN OF SOUTHOLD—BUILDING DEPARTMENT H 2t Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 hftps://www.southoldtownny.gov Floodplain Development Permit Application PROPERTY INFORMATION: Flood Zone: FIRM Panel: , SCTM#1000- Address: City: �yLO�� �� AIXZip: �l CONTACT PERSON: . Name: �, TPhone#: Mailing Address: PROJECT DESCRIPTION: SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity esidential (1 to 4 families) ❑New structure ❑ Residential (more than 4 families) ❑ Demolition of existing structure ❑ Combined use ❑ Replacement of existing structure ❑Non-residential ❑ Relocation of existing structure ❑ Elevated ❑ Addition to existing structure ❑ Flood proofed(attach certification) ❑ Alteration to existing structure ❑ Manufactured Home Other: SI/11% ❑ Located on individual lot ❑ Located in manufactured home park SECTION B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging C Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): Signature of Applicant: c%� G Date: S.C.T.M. NO. DISTRICT: 1000 SECTION: 53 BLOCK: 6 LOT(S):2Z I U.P. \ , MON. LOT 147 125- oo cn � 1 0 iiMWA� �. O 0 0,4 � p'' N LOT 148 a9�s ar"��a f Y MON. :1ti . H, .' O T �u fib. a "G/ � :::::. P/O LOT 149 o . h 30' LAND N/F 0F rimeER KASEY HARBES WALL / MON. FSPH�T DRIVEWAY U.P. ' ASPHALTDRIVEWAY w_ , GRAVE��RNEWAY ,� u� LOT540 .o S 13o00* P/0 LOT 149 PIP o ::•:+:•;::' .. ..... \ ISLAND VIEW LAN \ E FLOOD ZONE AE EL 6 FEMA MAP#3 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL EFFECTIVE 09/25/9/25/2009 009 LOCATIONS SHOWN ARE FROM FIELD OBSERVA77ONS AND OR DATA OBTAINED FROM OTHERS AREA:10,937.50 SQ.FT. or 0.25 ACRES ELEVA71ON DATUM: UNAUTHORIZED ALTERARON OR ADD177ON TO THIS SURVEY IS A V70LA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID 7RUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU77ON LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INS77TU770N, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE 77-IE EREC77ON OF FENCES, ADD177ONAL S7RUC77JRES OR AND 07HER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE S7RUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EWDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF: LOT 148 & P/0 LOT 149 CERTIFIED TO: THOMAS W. RONDI; MAP OF: PECONIC BAY ESTATES FILED: MAY 19, 1933 No. 1 124 SITUATED AT: ARSHAMONAQUE TOWN OF:SOUTHOLD SUFFOLK COUNTY, NEW YORK KENNETH ,M WOYCHUK LAND SURVEYING PLLC A. Professional Land Surveying and Design. � j P.O. Box 153 Aquebogue, New York 11931 FILE #224-44 SCALE: 1"=20' DATE:APRIL 8, 2024 PHONE (831)298-1588 FAX (631) 298-1588 N.Y.S. LISC. NO. 050882 pa. APP VED AS NOTED GATE• 5.B.P. FEE BY- NOTIFY BUILDING DEPARTMEN AT 631-765-1802 8AM TO 4PM FOR THE ELECTRICAL FOLLOWING INSPECTIONS: INSPECTION REQUIRED 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR FLOOD ZONE ' DESIGN OR CONSTRUCTON ERRORS COMALYWITH CHAPTER "46° FLOOD DAMAGE PREVENTION ^r)l1THOLD TOWN CODE. COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND C NDITIONS OF SOUTHOLD OWN ZBA SOUTHO TOWN PLANNING BOARD SOUTHO TOWN TRUSTEES N.YS.D C SO LD HPC SCH OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY �1 T 103f. 33%--G6s-6 add SPLIT SYSTE HEAT PUMP 9 000 --- IntertN mrne /n> - �MUZ-FS09NA - ---- — -- ----- — --- .MUZ-FS09NA• MITSUBISHI r ELECTRIC rx verve� ..m.0 I .raa x.uwcaps ARNIN6-: •r4���°�� SK OF ELECTRIC SHOCK.CAN SE INJURY R DEATH DISCONNECT ALL REMOTE ELECTRIC IYNER SUPPLIES BEFORE SERVICING b ! - WERTISSEMENT: Nci7ara h � SGUE DE CHOCS ELECTRKMS.PEUT CAUS` _.- 0 T_7 :FS BLESSURES ET MEME ENTRAIN P ER LA MO9Ett°*r� �� =,PER LES SOURCES D ALIMENTATION --ANCF AVAN'LE DFPA INt.,F N _ I I" ;y0�l.E�ti�'� %df_�'/�'�✓� ��"'°1 /r'<SU/315t�� S/�G/T LB,UIY /ti��a�•• yUYv��y s�Qe .Q�j ��2,�x.�Y1T�.�Y i���'� �UQ°�. ��Z�FS�9�� �,Iz a oYou���°� .rrwwrr► _._.._.__. P ------------------------------------- MITSUBISHI ELECTRIC i Von 111 _ r, 41 MSZ-FS09NA ' { 1 MITSUBISHI • WALL-MOUNTED INDOOR UNIT Arlk ELECTRIC • HYPER-HEATING OUTDOOR Job Name: System Reference: Date: Indoor Unit MSZ-FS09NA ......................................................................... Outdoor Unit MUZ-FS09NA I\1{19N9{N. ,IaIIIIIIIIIIIIIIIiIiIIIIIII�t1 µ �IIIIIIIIIIIIIIIIIIIIIIIIIIINIII�I� IIIIIIIIIIIIIIIIIIIIIIIIIIINIII G ''��Ilillllllllllllul�'''' INDOOR UNIT FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger,vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • 3D i-see Sensor®enables advance features: o Indirect or Direct Airflow for personalized comfort o Absence Detection for energy-saving mode • Double Vane features: o Separates airflow to deliver air across a large area o Simultaneously deliver to air separate sections of a room o Generates more comfortable natural airflow pattern • Multiple control options available: o Back-lit screen handheld remote controller(provided with unit) o kumo cloud®smart device app for remote access o Third-party interface options o Wired or wireless controllers • Triple-action Filtration:Nano Platinum Filter,Deodorizing Filter,&Electrostatic Anti-Allergy Enzyme Filter • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation OUTDOOR UNIT FEATURES • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • H2i plusTM performance offers 100%heating capacity at-5°and 70%to 81%heating capacity at-13°F • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: 1 • ; MUZ-FS09NA Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,000 Minimum Capacity BTU/H 1,700 Maximum Power Input W 1,000 Cooling at 95°F' Rated Power Input W 560 Moisture Removal Pints/h 0.6 Sensible Heat Factor 0.92 Power Factor[208V/230V] % 89.0/90.0 Maximum Capacity BTU/H 18,000 Rated Capacity BTU/H 9.600 Minimum Capacity BTU/H 1,600 Heating at 47°F' Maximum Power Input W 1,740 Rated Power Input W 620 Power Factor[208V/230V] % 92.0/92.0 Maximum Capacity BTUIH 14,170 Heating at 17°F3 Rated Capacity BTU/H 5,900 Maximum Power Input W 1,580 Rated Power Input W 450 Heating at 5°F' Maximum Capacity BTU/H 11,590 Maximum Power Input W 1,410 Heating at-5°Fs Maximum Capacity BTU/H 9,600 Heating at-13°F7 Maximum Capacity BTU/H 8,000 SEER 30.5 EER' 16.05 HSPF[IV] 13.5 COP at 47°F' 4.54 Efficiency COP at 17°F at Maximum Capacity3 2.63 COP at 5°F at Maximum Capacity° 2.2 COP at-5°F at Maximum Capacity° 2.2 COP at-13°F at Maximum Capacity? 1.89 ENERGY STAR®Certified Yes Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1S2 VAC 208/230 ElecMcal Voltage:Indoor-Outdoor,S2S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 Recommended Fuse/Breaker Size(Oudoor) A 15 Recommended Wire Size[Indoor-Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit MCA A 1.0 Fan Motor Full Load Amperage A 0.65 Fan Motor Type DC Motor Airflow Rate at Cooling,Dry CFM 137-167-221-304-381 Airflow Rate at Cooling,Wet CFM 117-143-190-261-328 Airflow Rate at Heating,Dry CFM 140-167-225-325-437 Sound Pressure Level[Cooling] dB[A] 20-23-29-36-40 Indoor Unit Sound Pressure Level[Heating] dB[A] 20-24-29-39-42 Drain Pipe Size In.[mm) 5/8[15.881 Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munseil 1.OY 9.210.2 Unit Dimensions W x D x H:In.[mm] 36-7/16 x 9-3/16 x 12(+11/16)[925 x 234 x 305(+17)] Package Dimensions W x D x H:In.[mm] 39 x 12-1/4 x 15-1/2[990 x 310 x 400) Unit Weight Lbs.[kg] 29[13.5] Package Weight Lbs.[kg] 34[15.4] Indoor Unit Operating Temperature Cooling Intake Air Temp[Maximum/Minimum]* °F 90 DB,73 WB/67 DB,57 WB Range Heating Intake Air Temp[Maximum/Minimum] °F 80 DB/70 DB NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor I/Outdoor) OF 70 DB,60 WB H 47 DB,43 WB 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions 'Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB 6Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB H-5 DB,-6 WB 7Heating at-13°F(Indoor//Outdoor) °F 70 DB,60 WB//-13 DB,-14 WB 'Indoor/Outdoor Unit Operating Temperature Range(Cooling Air Temp[Maximum/Minimum]): •Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range(Cooling Thermal Lockout/Re-start Temperatures;Heating Thermal Lockout/Re-start Temperatures): •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: 1 ' 1 MCA A 10.0 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate[Cooling/Heating] CFM 1141/1183 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 48 Sound Pressure Level,Heating' dB(A) 49 Outdoor Unit Compressor Type Twin Rotary Compressor Model SNB092FOAMT Compressor Rated Load Amps A 9.2 Compressor Locked Rotor Amps A 7.4 Compressor Oil[Type//Charge] oz. FV50S//0.35 External Finish Color Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W x D x H:In.[mm] 31-1/2 x 11-1/4 x 21-5/8[800 x 285 x 550] Package Dimensions W x D x H:In.[mm] 37 x 15 x 24-1/2[940 x 380 x 630] Unit Weight Lbs.[kg] 82[37] Package Weight Lbs.[kg] 89(40] Cooling Air Temp[Maximum/Minimum]* °F 115 DB 114 DB Outdoor Unit Operating Temperature Cooling Thermal Lockout/Re-start Temperatures— °F -4/0 Range Heating Air Temp(Maximum/Minimum] -F 75 DB,65 WB/-13 DB,-14 WB Heating Thermal Lockout/Re-start Temperatures" °F -18/-14 Maximum Charge Quantity Lbs,oz 2.0,9.0 Refrigerant Initial Charge Quantity Ft.[m] 25.0[7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 0.216[20) Gas Pipe Size O.D.[Flared] In.(mm] 3/8[9.52] Liquid Pipe Size O.D.[Flared] In.[mm] 1/4[6.35] Piping Maximum Piping Length Ft.[m] 65[20] Maximum Height Difference Ft.[m] 40(12] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17•F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions °Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB -Heating at-5°F(Indoor//Outdoor) °F 70 DB,60 WB//-5 DB,-6 WB 7Heating at-13°F(Indoor//Outdoor) °F 70 DB,60 WB//-13 DB,-14 WB •Indoor/Outdoor Unit Operating Temperature Range(Cooling Air Temp[Maximum/Minimum]): •Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range(Cooling Thermal Lockout/Re-start Temperatures;Heating Thermal Lockout/Re-start Temperatures): •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT ACCESSORIES: 1• BACnetl and Modbuse Interface ❑ PAC-UKPRC001-CN-1 CN24 Relay Kit ❑ CN24RELAY-KIT-CM3 IT Extender ❑ PAC-WHS011E-E kumo station®for kumo cloud• ❑ PAC-WHS01 HC-E Lockdown bracket for remote controller ❑ RCMKPICB Control Interface System Control Interface ❑ MAC-3341F-E Thermostat Interface ❑ PAC-US444CN-1 Thermostat Interface ❑ PAC-US445CN-1 USNAPAdapter ❑ PAC-WHS01UP-E Wireless Interface for kumo cloud° ❑ PAC-USWHS002-WF-2 Remote Sensor Wireless temperature and humitity sensor for kumo cloud' ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controller' - ❑ PAR40MAAU Wired Remote Controller Simple MA Remote Controller' ❑ PAC-YT53CRAUJ Touch MA Controllert ❑ PAR-CT01MAUSB Wireless Remote Controller kumo touch'"RedLINK-Wireless Controller ❑ MHK2 Blue Diamond(Advanced)Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑ X87-721 Blue Diamond(MicroBlue)Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑ X86-003 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Sensor Extension Cable—15 Ft. ❑ C13-103 Condensate Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Refco Condensate Pump(100-240 VAC) ❑ GOBI-11 Refoo Condensate Pump(100-240 VAC)up to 120,000 BTU/H ❑ COMBI Sauermann Condensate Pump ❑ 5130-230 (30A/600V/UL)[fits 2"X 4"utility box]-Black ElTAZ-MS303 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-White ❑ TAZ-MS303W Drain Hose Flexible Mini-Split Drain Hose ❑ DRX-16 Electro Static Anti-allergy Enzyme Fitter ❑ MAC-2330FT-E Fitter Platinum Deodorizing Filter ❑ MAC-3000FT-E 15'x 1/4"x 15'/318"Lineset(Twin-Tube Insulation) ❑ MLS143812T-15 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-30 Lineset 50'x 1/4"x 50'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T50 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) ❑ MLS143812T-65 NOTES: 'Requires MAC-3341F-E •M-Series EZ FITe Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT ACCESSORIES: MUZ-FS09NA Air Outlet Guide Air Outlet Guide ❑ MAC-881 SG Control/Service Tool M-&P-Series Maintenance Tool Cable Set ❑ M21 EC0397 - - - - - - USB/UART Conversion Cable(Required for all laptop connection) ❑ M21EC1397 Drain Socket Drain Socket ❑ MAC-871 DS Hail Guards Hail Guard ❑ HG-B4 14 Gauge.4 wire MiniSplit Cable-250 ft.roll ❑ S144-250 Mini-Split Wire 14 Gauge,4 wire MiniSplit Cable-50 ft.roll I❑ S144-50 16 Gauge,4 wire MiniSplit Cable-250 ft.roll ❑ S164-250 16 Gauge,4 wire MiniSplit Cable-50 ft.roll ❑ S164-50 Condensing Unit Mounting Pad:16"x 36"x 3" ❑ ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater ❑ MAC-640BH-U 18"Single Fan Stand ❑ QSMS1801 M 24"Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand—12"High ❑ OSMS1201 M Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT 1 • MSZ-FS09NA Unit: inch 7/16 x 1-1/16 Oblon hole 7/16 x 13/16 Oblong hole Installation late 4-I/I6 8-1/8 8-1/8 4-I/I6 aO 36-7/16 0 0+ ao I 7 \ o 35-5/8 3/8 aO 8-118 -3l Indoor unif 2 S/8 15-9/16 14-11116 3 9/16 9-3/16 Air in wall hole �3 3/16 Installation Plofe au Pi in Mu 2 1-9/16 2 - Drain hose M 2-3/8 27-11/16 6-5/16 4 2-3/8 1 II/16 Air out 4-5/8 5-3/16 2 5/8 2-11116 (06/09/12 KBTU/H) (15/18 KBTU/H) ln5Ulallon 11-7/16 0.D — Insulation 41-7/16 0.D Liquid line 1I/4 19-11/16 (Flared connection 11/4) a Li uid line 4114 19-II/I6 (Flared connection #1/4) Gas line 03/8 16-15/16 (Flared connection #318) Gas line #318 16-15116 (Flared connection 1112) Drain hose I Insulation 11-118 Connected part 05/8 0.1) Drain hose Insulation 11-1/8 Connected part >518 0.1) Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trans HVAC US LLC.All rights reserved. OUTDOOR • I Unit: inch REQUIRED SPACE `1 4 in. (100 mm) or more when front and sides of the unit are clear m a� U O 100<e Qi�('oo � R`NN.o�o Apr��ry� 15-3/4 Ak in Droin hole 01-21/32(MUZ-FS06109112NA) 1 Drain hole 01-5/16jMUZ-FS06/09/12NAH) Ain * m $\n.lZ ote O N N '2 When any 2 sides of left, right 1-9/16 and rear of the unit are clear Air OUt 2 x hole 3/8 x 13/16 Service panel 11/16 Hondle Liquid refrigerant pipe joint Refrigerant pipe(flared)01/4 a0 N N Gas refrigerant pipe joint N N N + Refrigerant pipe(flared)0 3/8 N Al r rn L N � rn m 11-29/3 5-11/32 -15/1 19-11/16 6-23/32 Bolt pitch for installation 31-1/2 2-3/4 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com 17 -0m.. FORM#MSZ-FS09NA&MUZ-FS09NA-202211 Intertek Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.