Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52371-Z
"of At 30ulyo�o Town of Southold * * P.O. Box 1179 o¢ 53095 Main Rd � Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46731 Date: 12/11/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 6305 Horton Ln Southold, NY 11971 Sec/Block/Lot: 54.-7-18.8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 09/10/2025 Pursuant to which Building Permit No. 52371 and dated: 10/20/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels and an energy storage battery (outdoors) to an existing single- family dwelling as applied for. The certificate is issued to: Adam Ableman ,Lisa Ableman Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114475 11/20/2025 PLUMBERS CERTIFICATION: Au orized Si ature ofSoaryo�c TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY COUNM BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52371 Date: 10/20/2025 Permission is hereby granted to: Adam Ableman 1512 10th Ave Brooklyn, NY 11215 To: install roof-mounted solarpanels and an energystorage battery(outdoors)to an existing single-family dwelling as applied for. Premises Located at: 6305 Horton Ln, Southold, NY 11971 SCTIVI# 54.-7-18.8 Pursuant to application dated 09/10/2025 and approved by the Building Inspector. To expire on 10/20/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 C -RESIDENTIAL $100.00 Total $200.00 Building Inspector + N ov 2 1 2025 ' NASSAU ELECTRICAL S U F 10 L K I N S I E C T O R 159 Route 25A, Building 1 Suite B Miller Place, NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 - E-Mail: Requests@SuffolkBEI.com t CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Element Energy LLC Certificate No.: 114475 Rough In Inspection Date: ' Final Inspection Date: Nov 20,2025 Application No.: Acct-9636142402 Building Permit No.: 52371 County Tax Map No.: 1000 054.00 07.00 018.008 LIPA Solar App No.: PAM-2025-392185, This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: Owner: LISA ABLEMAN Site Location: 6305 HORTONS LANE,SOUTHOLD, NY 11971 Owner's Address(if different): ( � Qx Residential Qx Indoor Basement Service Shed Commercial 2 Outdoor First Floor Pool Hottub ❑New Renovation Second Floor Attic/3rd Floor Q Garage I Addition ❑Survey PV Solar Generator Conversion Signs Battery Storage Other: INVENTORY Single Phase Heat Duplex Recpt� Ceiling Fixture Dual Func Breaker I Three Phase Hot Water GFCI Recpt� Wall Fixture Smoke f Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt� LED Lighting Smoke CO Combo Transformer Appliance CktO Dryer Recpt� Emergency Time Clock Disconnect�1 Switches Twist LockO Exit Fixtures0 Pumps GFCI Breaker Heat Pump Electric Heat O PoolLuminaire� Exhaust Fan + Other Equipment:System Size:10.88 kW Qty:25 Desc:QCELL Q.TRON BLK M-G2+435W Qty:25 Desc:Enphase IQ8MC-72-M-US Battery System Size:10 kWh Qty:1 !ff Desc:Enphase IQ Battery 10C The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Element Energy LLC License No.: 52689-ME Date Printed: Nov 20, 2025 Inspected I / Signature: OF SOUTyo� * TOWN.OF SOUTHOLD BUILDING DEPT. °ycoum . 631-765-1802 INSPECTI-ON [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [i,,TFINAL 5- cg�v2 j� [ ] FIREPLACE &=CHIMNEY [ ]' FIRE SAFETY INSPECTION [.. ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] . ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: Solar � ,� alp. a/, DATE - INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS b rn FOUNDATION (1ST) — — -------------------------------------- FOUNDATION (2ND) z 57 O 0) V l ►� ROUGH FRAMING& PLUMBING L r INSULATION PER N.Y. STATE ENERGY CODE — FINAL ADDITIONAL COMMENTS e l l l l S3 c�D 10 z'� + C A o z m O -o d b TOWN OF SOUTHOLD—BUILDING DEPARTMENT H =i Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 °��o• �aa Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: S�=SEP 1 2�25 ,� Applications and forms must be filled out in their entirety.Incomplete E Buil'cling Dernstment applications will not be accepted. Where the Applicant is not the owner,an `town Of v ouil;old Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: UZ k-1 SCTM# 1000- Project Address: ��� l ��n L�-�J Ovil, _ hc, Phone#: q ( � _ 8 S r�! c Email: `� Mailing Address: ,`�� .7 1 CONTACT PERSON: n " Name: Lor rG�br1 Mailing Address: Li ��u �� a �LV �,��`IFU�L� �, �/® •1 Phone#: 65 ) - 3 - 7 Email: ���I'�al- ��oC� �, Uhl DESIGN PROFESSIONAL INFORMATION: NJ Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: ' �� �teJ T Mp � e1-q 452, Phone#: �.. � 0" � Email: e..rm DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost ofProject: Other �: +"i CS 0 S al-r- v 10 K-UJ $ 'S a a. 5 — Will the lot be re-graded? ❑Yes ❑No ��� Will excess fill be re oved from ppremises? ❑Yes ❑No t,l o-f h o" 1 PROPERTY INFORMATIONIq � Existing use of property: 1 Intended use of property: K UL Zone or use distri tin which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesxNo IF YES, PROVIDE A COPY. eck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPI.lCATIOi4 IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ord'onances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are i punishable as a pass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. i Application Submitted By Qp�r` t name)-'Lo Y�1—eU 11 f- D) Qf-k� uthoriaed Agent ❑Owner Signature o�'App�li�can o Date: STATE OF NEW YORK) C SS: I COUNTY OF 40 1 lL ) Lo IrlrGl.l�J t being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, i � (S)he is the C,01+a-C*Y (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and I that the work will be performed in the manner set forth in the application file therewith. Sworbefore me this k II��, day of �,1P✓✓� ZO R Lary Public LOUIS J ROMEO PROPERTY OWNER AUTHORIZATION Notary Public,State of New York No.01 R06314813 (Where the applicant is not:the owner) Qualified in Suffolk County Commission Expires November 17,20Z6 residing at ..7 0 LLAI )r do hereby authorize LO COIL�- �1�� � � 7'kl to apply on my half to th Town of Southold Building Department for approval as described herein. `1 j Owner's Signature Date L�,S�- 0-b Lmo-n - Print Owner's Name I 2 1 AOWSSLING NSULTING 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com September 5,2025 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services Ableman Residence 6305 Hortons Lane, Southold, NY 10.875 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed 2x6 dimensional lumber spaced at 16"on center. Roof Material., Composite Asphalt Shingles Roof Slope: 26 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing=7 psf o New Solar Panels and Racking =3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =25 psf o Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 134 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2020 NYS Residential Code (2018 IRC). This analysis indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent IronRidge installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#14 lag screw is 194 Ibs per inch of penetration as identified in the National Design Standards (NDS)of timber construction specifications. Based on two screws with a minimum penetration depth of 2",the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two# 14 lag screws with a minimum of 2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of rafters, and condition of the roof, the panel supports shall be placed no greater than 48"on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2020 NYS Residential Code (2018 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. AVtnuly yours, Itisavio[ation.of the law for anyperson,unless acting under the direction of a licensed Scott E.Wyssli , PE professional,to alter an item in anyway.if an NY PE License No. item bearing the seal of a Ucensed professional NY COA#0022571 is altered,the altering licensed professional shall affix to their item their seatand the notation "altered by"foLlowed-by their signature and the date of such alteration,and a specific description of the alteration. jj t "� eY *,T Wyassling Consulting, PILLC 76 N.Nieadowbrook Drive,Alpine UT New York COA►#10022571 Signed 9/05/2025 Expires 7/31/2027 WyssUN�NSG ENPHASE. NORTH AMERICA 10 Battery 10C The IQ Battery 10C all-in-one AC-coupled system is compact,powerful, reliable,and safe.It has a total usable capacity'of 10.0 kWh and includes four embedded,grid-forming microinverters with a 7.08 kVA continuous power rating.It provides backup capability,and installers can quickly gNPHAS€ design the right system size to meet the customer's needs. 1 • a • o-r o ® Powerful Rated(continuous)output power 7.08 kVA' •Rated output current(@240 VL_LAC-) 29.5 A Provides 56 A peak current forthree seconds Rated neutral current(@120 VL_M AC-) 24 A' • Includes four embedded IQBB Microinverters Interconnection Single-phase • Most powerful microinverter with Nominal voltage 120/240 VAC- up to 2.1 kVA continuous power Nominal frequency 60 Hz G✓ Reliable Usable capacity 10.0 kWh' • Cools passively with no moving Ambient operating temperature range -20°C to 50°C(-4°F to 122T) parts or fans (charging)' Non-condensing • Uses wired communication for fast and consistent connection Ambient operating temperature range -20°C to 55•C(-4°F to 131•F) • Updates software and firmware (discharging)' Non-condensing remotely Chemistry Lithium iron phosphate(LFP) Simple Wall-mount or pedestal-mount(sold Mounting • Full integrated AC Batter system separately) Y 9 Y Y with neutral forming capabilities • Installs and commissions easily Product dimensions a' • Offers homeowners remote .�, monitoring and control from the ti Enphase App `' - • Field replaceable components 24.5" _.._ 0✓ Safe 15"• j3c Evaluated to UL 9540A,the highest 28^ 1a.a° industry standard for batter safety 1} - Y Y Y �4" Uses LFP chemistry for maximum safety and longevity •The 4"clearances on the sides and the top are per the UL 9540A evaluation,Enphase recommends 8"for ease of service. ••Follow the local and national regulations while planning.A 15"clearance in the front is recommended for ease of service. Refer to the following page for more details. m 2025 Enphase Energy.all rights reserved.Enphase,the a and CC logos,io,and certain other marks listed at DSH-00565-6.0-EN-2025-07-31 htics..ienonase.� :r,�rmar<-,s�r.e =a re trademarks of Enphase Energy.Inc.in the U.S.and other countries.Data subject to change. 'Prqduct.d'etaits, 0o Name IQ Battery 10C The IQ Battery 10C system with integrated IQ Microinverters(SKU:IQBBL,IQBBN) with a battery management system(BMS)as part of IQBL Microinverters,includes: Description Two 5 kWh battery units(ordering SKU:BO5-COI-USOO-1-3-DOM). One IQ Battery 1OCS cover kit with cover,interconnect cables and accessories(Ordering SKU:B1OCS-NC-0708-0-DOM). Model Number IQBATTERY-10C-1P-NA2 Ordering SKU Standard Domestic 5 kWh battery unit BO5-CO1-USO0-1-3 B05-001-USO0-1-3-DOM IQ Battery 1OC cover kit B1OC-NC-0708-0 B1OC-NC-0708-0-DOM IQ Battery 1OC unit 60%capacity,up to 15 years,or 6,000 cycles3 ® ,0 Rated(continuous)output power 7.08 kVAS Nominal voltage/range 240/211-264 VAC- Nominal frequency/range 60/57-63 Hz Rated output current(@240 VL-LAC-) 29.5 A Rated neutral current(@240 VL-NAC-) 24 A6 Peak output current(@240 VL-LAC-) 56 A(three seconds),44.8 A(ten seconds) Power Start capability Up to 90 A LRA7 Power factor(adjustable) 0.85 leading...0.85 lagging Maximum conductor size supported 3 AWG 40 A OCPD,requires a minimum of 8 AWG for one IQ Battery 10C Overcurrent protection device(OCPD) or 80 A OCPD,requires a minimum of 4 AWG for two or more IQ Battery 1OC6 Interconnection Single-phase AC round-trip efficiency9 90% Total capacity10 10.0 kWh Usable capacity" 10.0 kWh DC round-trip efficiency 96% Nominal DC voltage 76.8 V Maximum DC voltage 86.4 V 'The model number Is used on the product nameplate,Certificate of Compliance,and in official regulatory listings(e.g.,California Energy Commission).For all interconnection applications and permitting processes,please ensure that the model number is used—not the ordering SKU. 'Whichever occurs first.Restrictions apply. Supported in both grid-connected and backup/off-grid operations. 7.08 kVA,29.5 A for the balanced 240 VL-L loads. <A maximum of 24 A,120 V,- unbalanced loads can be supported along with 5.5 A,240 V r.L loads. 'Power Start capability may vary. a More than two 10 Battery IOC on a 4 AWG circuit protected by 80 A CCPD requires setting Power Control System:10 Battery Oversubscription. a AC to the battery to AC at 50%power rating. =The 10 Battery 10C is typically shipped with a state of charge(SoC)between 20%and 30%to ensure safe transportation and optimal battery health during storage and handling. "The battery's usable capacity supports loads and turns PV on(when off-grid),in normal daily operation.The usable capacity includes a safety-critical limit of 2%that safeguards the customer's asset In case of a long-duration grid outage.An additional 3%capacity is maintained for battery electronic sustenance at night.Refer to nttps://link.enphase.com/igbattery_usable_capacity_en-na for more information. DSH-GC565-6.0-EN-2025-07-31 Ambient operating temperature range -20°C to 50°C(-4°F to 122°F) (charging)12 non-condensing Ambient operating temperature range -20°C to 55°C(-4°F to 131°F) (discharging)13 non-condensing Optimum operating temperature range 0°C to 30°C(32°F to 86°F)14 Chemistry Lithium iron phosphate(LFP) Dimensions(H x W x D) 621 mm x 708 mm x 365 mm(24.5 in=28 in=14.4 in) Maximum lifting weight 57 kg(125 lb) Total installed weight for 144 kg(317lb) Enclosure Outdoor-NEMA 3R Cooling Natural convection Altitude15 Up to 3,000 meters(9,842 feet) Mounting Wall-mount or pedestal-mount(sold separately) '.'Features and compliance Compatibility Compatible with IQ and M Series Microinverters,IQ Meter Collar,IQ Combiner 6C, and IQ Gateway for grid-tied and backup operations. Communication Wired control communication Services Backup,Self-Consumption,TOU,and NEM integrity Monitoring Enphase Installer Platform and Enphase App monitoring options;API integration CA Rule 21(UL 1741-SA),IEEE 1547:2018(UL 1741-SB,3rd Ed.)CAN/CSA C22.2 No. 107.1-16 Compliance UL 954076,UL 9540A17,UN 38.3,UL 1998,UL 991,NEMA Type 3R,AC156 EMI:47 CFR, Part 15,Class B,ICES 003 Cell module:UL 1973,UN 38.3 Inverters:UL 62109-1,IEC 62109-2 What's in the•° There are a total of three boxes;two boxes contain the 5.0 kWh battery units,and the third box contains the IQ Battery 10C cover kit. 5.0 kWh battery unit Battery units Two 5.0 kWh battery units of IQ Battery 10C Mounting bracket Two mounting brackets for mounting the batteries on the wall Seismic screws Four seismic screws for securing the battery unit on the mounting bracket Mounting bracket fasteners Twelve M8 hexagonal Phillips screws with washers for mounting the second wall bracket on the preinstalled battery unit Drill template Two drill templates to mark drilling points and conduit entry locations on the wall IQ Battery 10C cover kit A reduction In charging power occurs at temperatures below 15°C and above 45°C. A reduction in discharging power occurs at temperatures below 0°C and above 50°C. Keeping the battery in this temperature range maximizes the battery life. "-Refer to the data sheet for all components used with the IQ Battery 10C to determine the maximum altitude.For example,the IQ Battery 10C has a maximum altitude limit of 3,000 meters,while the IC. Meter Collar has a limit of 2,500 meters.When used together,the maximum altitude is restricted to 2,500 meters. Following local standards,choose a non-habitable Indoor location(like a 2-car garage)or an outdoor location where the ambient temperature and humidity are within-20°C to 55°C(-4°F to 131°F) and 5%to 95%RH,non-condensing.Avoid direct sunlight to ensure the temperature stays in the optimal operating range.This ensures charging and discharging currents are not de-rated due to temperature. Evaluated to UL 9540A for thermal runaway fire propagation and reduced separation distance as required in 2021 IRC R328.3.1,2021 IFC 1207.1.5.and 2023 NFPA 85515.3.1 and 9.1.5.Follow all installation instructions and local codes and requirements of the Authority Having Jurisdiction(AHJ)when installing the Enphase Energy System. DSH-00565-6.0-EN-2025-07-31 What!s,in 00 C. Cover One cover for IQ Battery 10C Interconnect power cable One interconnect power cable assembly for internally connecting two battery units of IQ Battery 10C One interconnect control cable assembly for internally connecting two battery units Interconnect control cable of IQ Battery 10C,having one preinstalled control connector(without resistor)at one end Control connector with resistor One spare control connector with resistor for control wiring Raceway adapter Two raceway adapters for routing cables internally between two battery units Cable holder Two cable holders for cable management in wiring compartments Conduit covers One left-side and one right-side conduit cover to close unused conduit openings Cover locking screw Four cover lockings screws for securing the covers. Quick install guide(QIG) QIG for IQ Battery unit installation instructions 'Optional - - parts IQ8BL-RMA I08BL Microinverter for field replacement IQ8BN-RMA I088N Microinverter for field replacement B05-001-US00-1-3-RMA IQ Battery 10C 5.0 kWh battery unit for field replacement B10C-CX-0709-0 IQ Battery 10C cover for field replacement B05C-WB-0662-0 IQ Battery 10C wall bracket for field replacement B10C-PI-0550-0 IQ Battery 10C Pedestal Mount B05C-LH-0180-0 IQ Battery 10C Lifting Handles.Includes one left-side and one right-side lifting handle B05C-ACFB-0138-0 IQ Battery 10C AC filter board for field replacement B05C-NCANB-068-0 IQ Battery 10C control communication board for field replacement B05C-CS-0161-0 IQ Battery 10C control switch for field replacement B05C-NLTB-051-0 IQ Battery 10C live and neutral terminal block for field replacement B05C-NGTB-051-0 IQ Battery 10C ground terminal block for field replacement B05C-NJTB-027-0 IQ Battery 10C jumper for the terminal block for field replacement B05C-NETB-049-0 IQ Battery 10C end stop and end cap of terminal block for field replacement B10C-PIC-0350-0 IQ Battery 10C Interconnect power cable for field replacement B10C-CIC-0300-0 IQ Battery 10C Interconnect control cable for field replacement B05C-CP-031-0 IQ Battery 10C conduit plug(large)for field replacement B05C-CP-026-0 IQ Battery 10C conduit plug(small)for field replacement B05C-CH-0132-0 IQ Battery 10C cable holder for field replacement B10C-RA-050-0 IQ Battery 10C raceway adapter for field replacement B05C-CC-090-0 IQ Battery 10C conduit cover for field replacement B05C-WC-0620-0 IQ Battery 10C wiring cover for field replacement B05C-CAT-0100-0 IQ Battery 10C internal cables to connect AC filter board and terminal blocks 0SN-00565-6.0-EN-2025-07-31 Components of the Enphase Energy System —-- IQ Microinverters IQ Combiner 6C i IQ Series Microinverters pack IQ Combiner 6C consolidates more power into less space interconnection equipment into a than other rooftop solar systems single enclosure and streamlines and make rooftop solar more IQ Series Microinverters and 3i productive,reliable,smart,and IQ Battery 10C installation safe. by providing a consistent,pre- wired solution for residential applications. M IQ Meter Collar IQ Battery 10C accessories c IQ Meter Collar enables full homer -� IQ Battery 10C Lifting Handles backup with IQ Battery 10C, j are reusable and ease o Enphase PV,and IQ Combiner 6C. the installation process.The IQ Battery 10C Pedestal Mount enables floor mounting of the IQ Battery 10C. DSH-CC565-6.0-EW W 25-07-31 Revision history Revisidn Date Descri,ption DSH-00565-6.0 July 2025 Added the domestic SKUs. DSH-00565-5.0 July 2025 Updated the description of the"Product details"section. Added a note to the total capacity in the"Battery"section. Updated the peak current. Updated the discharging power temperature range. Added the footnote in the altitude data. DSH-00565-4.0 May 2025 Two additional SKUs were added to"Optional accessories and replacement parts." Updated the clearance dimensions from 6"to 4"in the product dimensions image. DSH-00565-3.0 March 2025 Editorial updates. DSH-00565-2.0 February 2025 Updated the specifications for order code details. DSH-00565-1.0 November 2024 Preliminary release. OSH-00565-6.0-EN-2025-07-31 OCCUPANCY OR CONTRACTOR L 1 SA ABLE MAN ELEMENT USE IS UNLAWFULEj ENERGY WITHOUT CERTIFICATE SOLARISATTERYSACKUP1631.779.79931EZSYS.COM AHJ UTILITY SCOPE OF WORK ELEMENT ENERGY LLC TOWN OF SOUTHOLD LONG ISLAND POWER AUTHORITY (N) 10.875KW DC/8.000KW AC ROOF MOUNTED PV SYSTEM VICINITY MAP OF OCCUPANCY 7470 SOUND AVE, (25) Q.TRON MODULE Q.TRON BLK M-G2+436 MODULES (435W) ' ' `',yo•, MATTITUCK, NY 11962, USA (25) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS Via` °'s +1 631 760 7262 (01) ENPHASE IQ COMBINER 6C PANEL c`�o,• " LIC TYPE: HOME 01 ENPHASE IQ-10C-1 P-NA BATTERY IMPROVEMENT, MASTER CODES AND STANDARDS WITH AMENDMENTS ( ) 4` ELECTRICIAN 2020 BCNYS (01) ESTOP SWITCH LIC NO.: 67461-1-1I, 52689-ME 2020 FCNYS 2020 RCNYS Q 2017 NEC 6305 Hort6ns Ln, PROJECT INFO&ADDRESS Southold,NV 11971, United States Y LISAABLEMAN 6305 HORTONS LN, s _ SOUTHOLD, ENVIRONMENTAL ` ` NY 11971, USA WIND SPEED: 134 MPH SNOW LOAD: 25 PSF EXPOSURE CATEGORY: C SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC GENERAL NOTES SHEET INDEX It;is a violation of the taw for any perlson,unless PROJECT NOTES: acting:under.the direction of.a licen 3ed -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE PV_1 COVER SHEET professional,toatteraniteminany vay:lfan NATIONAL ELECTRIC CODERTICLE 690,ALL METER NO: 98364675 itembearin theseal.ofa 6censeif professional (NEC)( ) PV-2 SITE PLAN-1 g MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, PV-2.1 SITE PLAN-2 isaltered,.the altering licensed prof ssionatshall AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY PV-3 ATTACHMENT PLAN affix to their iterntheir-seal and the,citation HAVING JURISDICTION'S (AHJ)APPLICABLE CODES. PV-3.1 STRUCTURAL PLAN "altered by'followedhy their signatureand a � -THE UTILITY INTERCONNECTION APPLICATION MUST BE PV-3.2 ELEVATION PLAN date of such alteration,and a specific APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL APP O ED AS NOTED PV-4 ELECTRICAL description of theatteration. I CO OPERATION nxw-. B.P# 31 PV-4.1 ELECTRICAL CALCULATIONS -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-5 LABELS r` DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN FM . BY PV-6 RESOURCE DOCUMENT , ACCORDANCE WITH NEC 690.41(B) PV-6.1 RESOURCE DOCUMENTv..• NOTIFY BUILDING DEPARTMENT AT f u -ALL PV SYSTEM COMPONENTS; MODULES, PV-6.2 RESOURCE DOCUMENT I t n ti Ii UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT 631 765-1802 8AMTO4PM FOR THE PV-6.3 RESOURCE DOCUMENT FOLLOWING INSPECTIONS: COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN �� PV-6.4 RESOURCE DOCUMENT PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV FOUNDATION-TWO REQUIRED FOR POURED CONCRETE PV-6.5 RESOURCE DOCUMENT. -�,�....�.•/ MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 PV-6.6 RESOURCE DOCUMENT q onsu CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, P. ROUGH-FRAMING&PLIJIuIBIi Ju PV-6.7 RESOURCE DOCUMENT yssldo brook rive,, PLLC 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 3. INSULATION 76 N.MeaclotNbrook Drive,Alpine UT FINAL-CONSTRUCTION MUST PV-6.8 RESOURCE DOCUMENT" New York COA#.002257I -MAX DC VOLTAGE CALCULATED USING MANUFACTURER PV-6.9 RESOURCE DOCUMENT PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX BE COMPLETE FOR C.O. PV-6.10 RESOURCE DOCUMENT Signed 9/05/2025 DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. ALL CONSTRUCTION SHALL MEET THE PV-6.11 RESO RI�C��E DOCUMENT Expires 7/31/2027 -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC REQUIREMENTS OF THE CODES OF,NEW COMPLY WITH ALLCODE OF PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR YORK STATE. NOT RESPONSIBLE FOR NEW YORK STATE&TOWN DES DRAWN BY AH USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED DESIGN OR CONSTRUCTON ERRORS AS REQUIRED AND COND! NSO� AND LISTED FOR THE APPLICATION PER 690.4. SHALL BE DATE 9/5/2025 INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING SOUTHOLD TO OR LABELING [NEC 110.3]. SOUTHOLDT PLANNII� SIGNATURE REVISION -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL SOUTHO OWNTRLISTEF$ ELECTRICAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS N.Y.S. C INSPECTION REQUIRED PV-1 REQUIRED BY THE NEC AND AHJ. S OLDHPC CHD COVER SHEET SCORE OF WORK CONTRACTOR (N) 10.875KW DC/8.000KW AC ROOF MOUNTED PV SYSTEM ® ELEMENT (25) Q.TRON MODULE Q.TRON BLK M-G2+435 MODULES (435W) �. ENERGY (25) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS SOLARI (01) ENPHASE IQ COMBINER 6C PANEL BAttERYBACKUP1631.779.7993IE25Y5.COM (01) ENPHASE IQ-10C-1P-NA BATTERY ELEMENT ENERGY LLC (01) E-STOP SWITCH 7470 SOUND AVE, ,C_ MATTITUCK, NY 11952, USA 7O +1 631 760 7262 LIC TYPE: HOME O IMPROVEMENT, MASTER ELECTRICIAN (E)MAIN HOUSE �/ / )s LIC NO.: 67461-1-1I,52689-ME n` PROJECT INFO&ADDRESS ` LISA ABLEMAN ^�� \ 6305 HORTONS LN, / o SOUTHOLD, i!? NY 11971, USA SYSTEM SIZE nj DC SIZE: 10.875 KW DC-(STC) (E)POOL ? AC SIZE: 8.000 KW AC tS' Its.a violation of the law for any person,unless ' acting underthe'direction of alicensed professiotiat,to alteran item In anyway.If an item beanngthe�seal of a licensed professional is altered,the altering licensed professional sha affix to their item their.seal and the notation �Q �0 "altered by"followed by their signature and the A\Al (L nj date of such-alteration,and'a specific " Q CAI I description of the alteration. IN, / 0 / fl Ste' N, `,I ysslirng Consulting,PLLC 76 N Meadowbrook Drive,:Alpirte UT LEGEND New York COA#0022571 ®FIRE PATHWAYS Signed 9/05/2025 PROPERTY LINE Expires 7/31/2027 0 FENCE DRAWN BY AH ® SKYLIGHT/CHIMNEY DATE 9/5/2025 O ❑ VENT/OBSTRUCTION REVISION SIGNATURE SITE PLAN-1 TOTAL ROOF SQUARE FOOTAGE IS:2,842.09 FTz PV-2 SCALE:1/64"=1 9-011 NEW ARRAY SQUARE FOOTAGE IS: 525.48 FTz COVERED BY SOLAR IS: 18.49% SITE PLANA CONTRACTOR SCOPE OF WORK (N) 10.875KW DC/8.000KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:2,842.09 FTZ �. ELEMENT (25) Q.TRON MODULE Q.TRON BLK M-G2+435 MODULES (435W) NEW ARRAY SQUARE FOOTAGE IS:525.48 FTZ ® ENERGY (25) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS COVERED BY SOLAR IS: 18.49/o SOLAR I BATTERY BACKUP,I631.779.7993IE25Y5.COM (01) ENPHASE IQ COMBINER 6C PANEL (01) ENPHASE IQ-10C-1 P-NA BATTERY ELEMENT ENERGY LLC (01) E-STOP SWITCH 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN (E)UTILITY METER LIC NO.: 67461-1-1I, 52689-ME (UNDERGROUND SERVICE) (POLE MOUNTED) PROJECT INFO&ADDRESS LISA ABLEMAN 6305 HORTONS LN, SOUTHOLD, (N)ENPHASE IQ METER COLLAR NY 11971, USA IN FORM 2S METER PAN (OUTSIDE HOUSE) SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC (E)MAIN SERVICE PANEL (N)VISIBLE LOCKABLE LABELED (INSIDE BASEMENT) AND FUSEDiAC-DT�ONNECT (UTILITY DISCONNECT) ( -E-NP HAS E-1OC-BATTERY (OUTSIDE HOUSE) OiC1` -10ta_SIDE-HOUSE) j"�` (N)ENPHASE IQ COMBINER 6C PANEL O/l s WITH ENPHASE IQ GATEWAY Vy (OUTSIDE HOUSE) (N)E-STOP SWITCH �Yy ® °B (OUTSIDE HOUSE) It is a violation of the law forany person,unless CO ( o /Q acting underthe direction of a licensed ® .i (E)SUB PANEL AS BACKUP PANEL professional,Matter an item in any way.if an (INSIDE HOUSE) item bearingthe seal ofa.licensedprofessional L ® is altered,the altering Ucensed professionals Q affix to their item their.seal and the notatio "attered by"followedby their signature and the date of such alteration,and a specific IADDER ACCESS p description ofthe.alteration. I 3' o® yssling Consulting, PLLC "0" p 76 N Meadowbrook Drive,Alpine UT LEGEND :0" New York COA#0022571 ®FIRE PATHWAYS Signed 9/05/2025 PROPERTY LINE Expires 7/31/2027 0 FENCE ® SKYLIGHT/CHIMNEY DRAWN BY AH O ❑ VENT/OBSTRUCTION (N)CONDUIT RUN DATE 9/5/2025 REVISION r Nr(255jTG.TRON MODULE Q.TRON BLK M-G2+435 ,0" SIGNATURE SITE PLAN-2 MODULES WITH ENPHASE IQ8MC-72-M-US (240V) PV-2.1 SCALE:1/16" = V-0" MICROINVERTERS UNDER EACH MODULE(240V) SITE PLAN-2 CONTRACTOR ROOF SECTION(S) ELEMENT ROOF MATERIAL- E ENERGY COMPOSITE SHINGLE SULARIBATTERY BACKUP 1631.779.79931E2SYS.COM ROOF 1 RAFTER SIZE-2"X6" O.C. SPACING- 16" ELEMENT ENERGY LLC MODULES- 15 7470 SOUND AVE, ROOF MATERIAL- 7" MATTITUCK, NY 11952, USA -COMPOSITE SHINGLE +1 631 760 7262 - ROOF 2 RAFTER SIZE-2"X6" 4'-3" 29'-10" 16'-7" 11'-3" 61-4" LIC TYPE: HOME O.C. SPACING- 16" N IMPROVEMENT, MASTER MODULES-6 ELECTRICIAN I I I I I I I I I I I I I I I I I I I I I I LIC NO.: 67461-HI,62689-ME ROOF MATERIAL- I I I I oil, I I I I I I I I I I I I I I I I I I I I I I I I COMPOSITE SHINGLE I I I 1 1 1 I I 1 I 1 1 1 1 I ROOF 3 RAFTER SIZE-2"X6" i i i i i i ii i i i i i i i i i i I 1 i i i i i PROJECT INFO 8 ADDRESS O.C. SPACING- 16" I I I I I I II I I I I l I I I I I I I I I I I I I I I I I I I I LISA ABLEMAN MODULES-4 i I I i i i i 1 1 1 1 1 1 I I I 1 1 1 1 1 1 1 1 1 I I = I I I 1 1 1 1 1 6305 HORTONS LN, 1 1 1 1 1 1 1 1 1 1 i i i 1 1 1 1 I I I 1 I I I I I I SOUTHOLD, I I I I I I I I I I I 1 1 1 1 1 I I I 1 1 I I I I I I I I NY 11971 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I 1 1 — 1 1 1 1 Q 1 1 1 1 1 1 1 1 1 , USA 1 1 1 1 1 1 1 1 I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ri -t:t I I O1 1 1SYSTEM SIZE 1 1 1 1 DC SIZE: 10.875 KW DC-(STC) 1 1 11 41 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AC SIZE: 8.000 KW AC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4'-0" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 It is a violation.of the law for any'Rerson,unless acting underthe direction of.a licensed professional,tb.alter an item.in aTy way.ff an ARRAY 1 item bearingthe seat of a license a professional TILT- 26 DEG 'is altered,the.altering licensed professional shall AZIMUTH - 213 DEG ARRAY 3 affixtotheiritem.their.sealandthienotation TILT- 26 DEG "altered by"Wtowedby their sigrtaturea d. a e of such alteration,and a spe�ifi AZIMUTH - 212 DE :��- �� rat•?/ soript;onoftl,eafteration. _ s 1011 2" O /fir 6+pl r p i n i ( , i 11 -3 11 DEAD LOAD CALCULATION o�� w 1 1 1 1 1 1 1 1 1 ,tip O - CLAMP i I 1 TOTAL \• 1 T T T BOM QUANTITY LBS/UNIT 1 1 1 1 1 1 1 1 WEIGHT(LBS) b SIB • - IRONRIDGE HALO ULTRA GRIP 1 I I = Q.TRON MODULE Q.TRON BLK 25 46.7 1167.50 yssling Consulting, PLLC M-G2+435 MODULES 76 N.Meadow brook Drive,Alpine UT - IRONRIDGE AIRE Al i New York COAif0022571 MID-CLAMP 28 0.15 4.20 Signed 9/05/2025 --------- - RAFTER END-CLAMP 44 0.15 6.60 Expires 7/31/2027 RAIL LENGTH 26 6.36 165.36 1 1 1 1 1 1 1 1 1 SPLICE BAR 04 0.525 2.10 75 - TOTAL MOUNT DRAWN BY AH IRONRIDGE HALO ULTRA 75 0.57 42.75 GRIP DATE 9/5/2025 ARRAY 2 ENPHASE IQ8MC-72-M-US 25 2.43 60.75 REVISION TILT- 26 DEG (240V) MICROINVERTER SIGNATURE TOTAL WEIGHT OF THE SYSTEM (LBS) 1449.26 ATTACHMENT PLAN AZIMUTH - 213 DEG TOTAL ARRAY AREA ON THE ROOF(SQ.FT) 525.48 PV-3 SCALE:1/$11=11-011 WEIGHT PER SQ.FT. (LBS) 2.22 WEIGHT PER PENETRATION (LBS) 19.32 ATTACHMENT PLAN CONTRACTOR ® ELEMENT ENERGY SOLARI BATTERY BACKUP1931.779.7993I E25YB.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS MODULE BOTTOM MOUNTING CLIP LISAABLEMAN CLAMP w 4" BOLT 6305 HORTONS LN, SOUTHOLD, AND LOCK WASHER NY 11971, USA Q.TRON MODULE Q.TRON BLK M-G2+ 435 SYSTEM SIZE MODULE DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC IRONRIDGE AIRE Al 3, BOLT 7 (E) COMPOSITE SHINGLE IRONRIDGE QUICKMOUNT HUG (2) #14 x 3 STAINLESS STEEL �F SCREWS, SELF DRILLING Co SCREW, WITH MINIMUM 2" EMBEDMENT It is a violation of the law for any person,un s }, acting under.the direction of_alicensed9- o c-�`� professional to item in anyway.ff an ° -,, y+� F\• t SSI �' item bearingthe seat of a licensed professional L��! 'is altered,the altering licensed professional shalt yssling Consulting, PLLC affix to their.item their.seal and the notation 7€N. Meadowbrook Drive,Alpine UT (E) RAFTER 2"X6" @ 16" O.C "altered by"followed by their signature and the New York COA!#0022571 date of such alteration,and a speciflc description of the alteration. Signed 9/05/2025 Expires 7/31/2027 DRAWN BY AH DATE 9/5/2025 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR : ELEMENT LEGEND NOTE DISTANCE BETWEEN ELECTRICAL EQUIPMENT SHOULD BE MINIMUM 6 . El N ENERGY UM UTILITY METER - BATTERY WILL BE LOCATED AT LEAST 3FT AWAY FROM ALL DOORS SOLAR I BATTERY BACKUP 1631.779.79931E25Y5.CDM AND WINDOWS INTO DWELLING. ELEMENT ENERGY LLC ENPHASE IQ 10C-1P-NA - ALL EQUIPMENT SHOULD BE A MINIMUM OF 3' FROM GAS METER BAT BATTERY 7470 SOUND AVE, 24.5 x 28 x 14.4 MATTITUCK, NY 11952, USA +1 631 760 7262 CB IQ COMBINER PANEL 6C LIC TYPE: HOME 26.77"x 18.11" x 8.66" IMPROVEMENT, MASTER EMC ENPHASE IQ METER ELECTRICIAN COLLAR LIC NO.: 67461-HI, 52689-ME ACD AC DISCONNECT 17.5"X 10.5"X 6.5" PROJECT INFO&ADDRESS LISA ABLEMAN RPO E-STOP SWITCH TO PV ARRAY 6305 HORTONS LN, (E) CHIMNEY SOUTHOLD, (N) ENPHASE IQ METER COLLAR IN NY 11971, USA FORM 2S METER PAN (OUTSIDE HOUSE) SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) (E) CHIMNEY AC SIZE: 8.000 KW AC It is a violatioh.of the law for any person unless acting under the direction of a licensed professional,to alter an item in anyway If an item bearingthe seat of aUcensed professional is attered,the altering licensed professii,nat shall affix to their item their seal and the note ion "attered by"followed by their'signature and the date of such alteration,and a specific description of the alteration. BAT Ll f f� yc4a^ CB AC •,I w _S?_"f•J ��i LID �yssllng Consulting-, PLLC 76 N Meadowbrook Drive,Alpine UT (N) ENPHASE IQ 10C-1P-NA (E) UTILITY METER New York COA#0022571 BATTERY 10.0 KWH NEMA 3R GRADE LEVEL GRADE LEVEL (UNDERGROUND SERVICE) Signed 9/05/2025 (OUTSIDE HOUSE) (N) VISIBLE LOCKABLE LABELED AND (ON POLE) Expires 7/31/2027 (ON H-FRAME) (N) E-STOP SWITCH (OUTSIDE HOUSE) FUSED AC DISCONNECT DRAWN BY AH (UTILITY DISCONNECT) (OUTSIDE HOUSE) DATE 9/5/2025 REVISION (N) ENPHASE IQ COMBINER 6C PANEL WITH ENPHASE IQ GATEWAY SIGNATURE 1 ELEVATION PLAN (OUTSIDE HOUSE) PV-3.2 SCALE:3/16°=V-011 ELEVATION PLAN CONTRACTOR METER NO: 98364675 TO UTILITY GRID (N)(1) E-STOP SWITCH L1L2N ELEMENT (OUTSIDE HOUSE) LINE (E)BI-DIRECTIONAL UTILITY4 N ENERGY #14 AWG THWN-2 METER 1-PHASE,3-W, SOLARI BATTERY BACKUP 1631.779.79931 E2SYS.COM CT-WIRES M 120V/24OV,200A RATED (N)(1)ENPHASE IQ COMBINER 6C LOAD (UNDERGROUNG SERVICE) (POLE MOUNTED) ELEMENT ENERGY LLC WITH ENPHASE IQ GATEWAY, (3)20A&(1)40A/240VAC CIRCUIT 7470 SOUND AVE, #18 THWN-2 BREAKER,125A RATED A L1 SUPPLY SIDE TAP MATTITUCK, NY 11952, USA (OUTSIDE HOUSE) L2 +1 631 760 7262 (N)PV 20A2P (N)ESS 40AI2P (E)MAIN BREAKER TO LIC TYPE: HOME —� LINE HOUSE 240 V,200A/2P (N)PV 20A2P L, N G d (TOP FED) IMPROVEMENT, MASTER (N)PV 20A2P UNE I I T I (E)MAIN SERVICE PANEL ELECTRICIAN (N)(1)ENPHASE IQ I I I I 200A RATED,240V LIC NO.: 67461-HI,52689-ME METER COLLAR IN • I I I I (INSIDE BASEMENT) eanrzP FORM 2S METER PAN LOAD (N)(25)Q.TRON MODULE Q.TRON BLK M-G2+ RMIA (OUTSIDE HOUSE) I LOAD LINE SIDE PROJECT INFO&ADDRESS 435 MODULES I INTERCONNECTION LOAD 11 MICROINVERTERS IN BRANCH CIRCUIT 1 CONTROLLER I AT MAIN PANEL LISA ABLEMAN &ACKFEEO I I PER ART.705.12(A) 6305 HORTONS LN, (N)(1)AC DISCONNECT: GEC SOUTHOLD IQ GATEWAY ___ ____ VISIBLE,LOCKABLE AND LABELED EXISTING GROUNDING I PV-1 w-2 w-3 PVa MT-1 MT-1 EVC 1— J 100A FUSED,(2)60A FUSES,240V ELECTRODE SYSTEM NY 11971, USA J I J L1 L2 L1 L2 L1 U L1 L2 � _ N G - NEMA 3R,UL LISTED TO EARTH m ��13� I 4 (UTILITY DISCONNECT) REF.NEC 250.52, I — I (OUTSIDE HOUSE) 250.53(A) SYSTEM SIZE 10 MICROINVERTERS IN BRANCH CIRCUIT 2 I It is a violation of the law for any person,.unless (N)MAIN BREAKER TO acting under the direction of a licensed DC SIZE: 10.875 KW DC- STC HOUSE 240 V,60A/2P professional,to.alter an item in anyway.ff an AC SIZE: 8.000 KW AC I - I - I 3 I I (TOP FED) item bearingthe seal of a licensed professional (E)SUB PANEL AS ~ J — ~ —— ~ J EL2 BACKUP PANEL60A is altered,the altering licensed professional shall (N)PV 6OA2P RATED,240V affix to their.item their seal and the notation (INSIDE BASEMENT) "altered by"-followed'bytheirsignature and the 4 MICROINVERTERS IN BRANCH CIRCUIT 3 N I date of such alteration,and a specific ° I i L— — _1 NOTE: zcrtptl �fine attratPo... - ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. ——————— — — ——J PARTIAL HOME BACKUP. , (N)(25)ENPHASE IQBMC-72-M-US INSTALL A NEW 60A MAIN BREAKER IN EXISTING 60A �F �� �' �'i� • (240V)MICROINVERTERS ONE I RATED SUB PANEL. c��` UNDER EACH MODULE(240V) A V� t (3)#12 Q-12-RAW-300 CABLES J L I INVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS t t ENPHASE IQ8MC-72-M-US(240V) Q.TRON MODULE Q.TRON BLK M-G2+ —J MANUFACTURER/MODEL# MANUFACTURER/MODEL# Dc G — MICROINVERTER 435 MIN/MAX DC VOLT RATING 22V MIN/58V MAX VMP 33.14V ,. �k_. } BATTERY 2 MAX INPUT POWER 460W IMP 13.13A ;•L� NOMINAL AC VOLTAGE RATING 240V/211-264V VOC 39.60V �`,(N)(N)(1)ENPHASE IQ-1OC-1P-NA MAX AC CURRENT 1.33A ISC 13.82A BATTERY 10.0 KWH NEMA 3R MAX MODULES PER STRING 12(SINGLE PHASE) TEMP.COEFF.VOC -0.24%/'K Ylyssling Consulting,ing, PLLC (OUTSIDE HOUSE) MAX OUTPUT POWER 320 VA MODULE DIMENSION 67.8"L x 44.6"W x 1.18"D(In Inch) 76 N Meadowbrook Drive,Alpine UT New York COA#0022571 PHASE CONDUCTOR QTY, SIZE AND TYPE GROUND CONDUCTOR QTY, SIZE CONDUIT CONDUIT- Signed 9/05/2025 ID PER CONDUIT NEUTRAL QTY, SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE Expires 7/31/2027 1 3 AWG #12 Q CABLES,THHN NA NA NA 1 AWG#8 BARE,COPPER EGC litPVC DRAWN BY AH DATE 9/5/2025 2 2 AWG#8 THWN-2,COPPER NA NA NA 1 AWG #8 THWN-2,COPPER EGC PVC REVISION SIGNATURE 3 2 AWG#6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER EGC PVC PV-4 4 2 AWG#6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER EGC PVC ELECTRICAL CONTRACTOR ELEMENT " ® ENERGY AMBIENT TEMPERATURE SPECS NUMBER OF CURRENT S13LARI BATTERY BACKUP1631.779.7993IUsYsxam PERCENT OF VALUES CARRYING CONDUCTORS IN EMT RECORD LOW TEMP -15° ELEMENT ENERGY LLC 7470 SOUND AVE, AMBIENT TEMP (HIGH TEMP 2%) 310 0.80 4'6 MATTITUCK, NY 11952, USA CONDUIT HEIGHT 7/811 0.70 7-9 +1 631 760 7262 ROOF TOP TEMP 530 0.50 10-20 MPROVEM NLIC TYPE: TTEMASTER CONDUCTOR TEMPERATURE RATE 750 ELECTRICIAN LIC NO.: 67461-1-1I,52689-ME MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°K PROJECT INFO&ADDRESS LISA ABLEMAN 6305 HORTONS LN, SOUTHOLD, CALCULATIONS: NY 11971, USA 2. PV OVER CURRENT PROTECTION SYSTEM SIZE 1. CURRENT CARRYING CONDUCTOR ...NEC 690.9(B) DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC = TOTAL INVERTER O/P CURRENT x 1.25 It is a violation of the law forr�n�{Ye7ii;Ufs[e�s (A) BEFORE IQ COMBINER PANEL = (25 x 1.33) x 1.25 = 41.56 A acting under the directiono. alicensed an AMBIENT TEMPERATURE - (31)OC ...NEC 310.15(B)(2)(a) SELECTED OCPD = 50 A ...NEC 240.6 item.bearingthese6tof to I rased. way tsio itembearingthesealofa[i nsedprofessiona.l TEMPERATURE DERATE FACTOR - 0.94 ...NEC 310.15(B)(2)(a) Is altered,the alteringglicen ad professional'shatt GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) 3. BATTERY OVER CURRENT PROTECTION affix to their itemtheinseal i ndthenotation a re f It d by the r"signature and the n,and a specific CONDUCTOR AMPACITY = BATTERY O/P CURRENT x 1.25 description of the a[teration _ (INV O/P CURRENT ) x 1.25 / A.T.F / GX ...NEC 690.8(B) _ (29.5 x 1) x 1.25 = 36.88 A ` _ [(11 x 1.33) x 1.251 / [0.94 x 0.81 SELECTED OCPD = 40 A ...NEC 240.6 o . h = 24.32 A � �. �r1' L1 , SELECTED CONDUCTOR - #10 THHN ...NEC 310.15(B)(16) i G 4 9,20, (B) AFTER IQ COMBINER PANELn.yssling Con. PLLC TEMPERATURE DERATE FACTOR - 0.94 76 N. Meadowbrook Drive,Amine UT GROUPING FACTOR - 1 New York C©A#iF.0022571 Signed 9/05/2025 Expires 7/31/2027 CONDUCTOR AMPACITY _ DRAWN BY AH _ (TOTAL INV O/P + BAT O/P CURRENT ) x 1.25 / 0.94/ 1 ...NEC 690.8(B) _ DATE 9/5/2025 [((25 x 1.33)+29.5) x 1.25] / [0.94 x 1] = 8 REVISION 3.44 A SIGNATURE SELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16) PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR Solar Module Solar Module S7ET P ENPHASEIQ UM ELEMENT Microinverters 13 COMBINER PANEL ENERGY Outside DoorCBOANEL AC DISCONNECT MAIN SERVICE 50LARI SATTERY BACKUP1631.779.79931 E25YS.COM 3,4,8,12 or PANEL IQCOLLERTIE Outside Door ELEMENT ENERGY LLC OEM Cables should be marked by the manufacturer Door 3,9,10 7470 SOUND AVEInside Door , 5,6,7 0 3,5,$ OUTSIDE Door MATTITUCK, NY 11952, USA 5,6,7,13 +1 631 760 7262 *CustomLIC TYPE: HOME NEC 690.13(B)NEC 705.12(A IDirectory NEC 690.56(B)NEC 705.12(B)(3) Placard IMPROVEMENT, MASTER ENCHARGE NEC 705.10 NEC 690.13(B) ELECTRICIAN BATTERY NEC 690.13(B) NEC 690.13(B) LIC NO.: 67461-1-1I,52689-ME NEC 705.13 NEC 690.56(B) NEC 690.56(B) NEC 690.56(B) NEC 705.10 NEC 705.10 NEC 705.10 12 NEC 705.12(A) NEC 705.12(A) PROJECT INFO&ADDRESS NEC 690.13(B) NEC 705.12(B)(3) NEC 705.12(A) NEC 705.12(B)(3) NEC 705.12(B)(3) LISA ABLEMAN 6305 HORTONS LN, SOUTHOLD, F-110 ® CAUTION.SONY 11971, USA ELECTRIC H CK HAZARDF-8] SYSTE CONNECTED SYSTEM SIZE S O IF A GROUND FAULT IS INDICATED DC SIZE: 10.875 KW DC-(STC) NORMALLY GROUNDED CONDUCTORS AC SIZE: 8.000 KW AC MAY BE UNGROUNDED AND ENERGIZED SOLAR PV SYSTEM EQUIPPED] —777---7-773 — WITH RAPID SHUTDOWN It is a viola on of the law for any person,unless CAUTIONacting und�the direction f a licensed TURN RAPID SHUTDOWN profession to alter an it m in any way.ff an F2] I A, s SWITCH TO THE "OFF"POSITION TO saaae�crnic item bearinthe seal of a ,[licensed professional • SHUT DOWN PVSYSTEM wp_N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE ELECTRIC SHOCK HAZARD AND REDUCE red,t�e altering licelsed professional shalt SHOCK HAZARDL—L—ij FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOW THE DC CONDUCTORS OF THIS IN THE ARRAY a 1x,othei item their sea'and the natation PHOTOVOLTAIC SYSTEM ARE UNGROUNDED "altered by"followed by their signature and the AND MAY BE ENERGIZED datf such alteration,and a specific -- des iption of the alteration. s 1� UTILITY METER CAUTION• SOLAR CIRCUIT (UNDERGROUND SERVICE) a I C�Q� �Iy,�� } �. • F3] I • (POLE MOUNTED) 3 ` Al ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS - ENPHASEIQMETER UTILITY DISCONNECT � n a,L�F�• iiI r LL TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ADISCONNECT COLLAR IN FORM 2S (OUTSIDE HOUSE) C' LOAD SIDES MAY BE ENERGIZED • • • OUTPUT • ■ • ■ METER PAN IN THE OPEN POSITION A (OUTSIDE HOUSE) • • OPERATING • • • 208 • COMBINER PANEL MAIN SERVICE PANEL (OUTSIDE HOUSE) !� (INSIDE BASEMENT) O� r� l'� �`�2__ 30- BATTERY 4 WARNING - )(OUTSIDE HOUSE E-STOP SWITCH ` �vs 10 (OUTSIDE HOUSE)No user serviceable parts;inside _ - ENERGY - • ,yssling Consulting, PLLC • 2AC DISCONNECT76 N E Meadowbrook Drive,Alpine UT RATED AC WARNING - OUTPUT New York CQA#0022571 NOMINALOPERATING • SUB PANEL AS [5 ] TRI POWER • BACKUP PANEL Signed 9/05/2025 (INSIDE BASEMENT) Expires 7/31/2027 • • - DRAWN BY AH DATE 9/5/2025 6] WARNING: _ • • • 3 • REVISION POWER SOURCEPV ARRAY SIGNATURE PV-5 F7] INVERTER OUTPUT CONNkTION DO NOT RELOCATE THIS OVERCURRENTLABELS CONTRACTOR ELEMENT _ � rn ® EN RGY Q.TRON BLK r l� _. _"`��tON BLK M-G 2+ SERIES BDLAR I BATTERY BACKUP 1631.779.79931 E25Y5.COM II, i ■Mechanical Specification ELEMENT ENERGY LLC M-G2+ SERIES oceils (including "'° 7470 SOUND AVE, Format 67B m 44.6 in MIS it Indutlin frame) (1722mm 1134mm 30mm) USA Vie ight 4671bs(212kg) MAT , 5 , +1 631 760 7262 Front Cover 0.13 in(32 mm)thermally pre-stressed g!ass ,sarunm.n -m s� with anti-reflection technology I , LIC TYPE: HOME 415-440Wp 1108CMIS Back Cover Composite film IMPROVEMENT, MASTER O Frame Black anodised aluminium 22.5/o Maximum Module Efficiency - ELECTRICIAN Cell 6=18 monocrystalline O.ANTUM NEO solar half cefls �-{� ,,,�,,, Junction box 2,09-3.98 in*1.26-2.36 in-0.59-D.71 in -:,�.m I LIC NO.:67461-HI,52689-ME (?3-i01mm"32-60mm><15-18mm),Protection class IP67,with bypass diodes Cable 4 min'Solar cabl_;I+i>68 9 m p7S0mm1()268.9 in(1750mm) _--_--- f qt p em�.T„ ------- ----- - MODEL CITRON BLK r,M1 G2+ Connector SlautiiiMC4;IP66 „�iC-R�m,� PROJECT INFO&ADDRESS ■Electrical Characteristics LISA ABLEMAN 6305 HORTONS LN _Po_wERcw_ss 415 a2_o a25 _430 ass _ MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 M SOUTHOLD r Power at MPP' P_ [YV] 415 420 425 430__ 435_ _ 440 NY 11971, USA r3.r9NTUM High performance Ocells N-type - Short Circuit Current' -- - !� [A] 13.49 13.58 - - 13.66 13.74 13.82 13.90 Nter, .- ._._._ _ .. .. _ ._. ZG solar cells E Open Circuit Voltage' M 38A7 3875 3903 3932 39.60 39.88 SYSTEM SIZE OANiTUM NEO Technology vrith optimized module layout f .Current at MPP I_ [A] 12.83 1291 12 98 13.05 13.13 1320 booss mod ule efficiency up to 22.5%. Voltage at MPP V_ M3.234 32.54 32.74 32.94 33.14 3333 DC SIZE: 10.875 KW DC-(STC) Efficiency' rl [%] 221-3 221.5 11.8 2rn.o 2223 _=5 AC SIZE: 8.000 KW AC A reliable investment MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.NMOT -. Inclusive 25,year product Lvartarty,and 25-year linear Power at MPP ,P,,,,.., [WJ 3t3J 3175 3272 325.0 328.8 332.6 YdaeratdIf performance:warranty. E Short Circuit Current !u [A] 10.87 10.94 17.00 11.07 _ 17.14 19.20 Open Circuit Voltage Vn_ (V) 36.50 36.77 37.04 3731 37.58 37.84 2 Current at MPP I_ [A] 10.10 . 10.15 1021 1027 1033 1038 Enduring high performance Voltage at MPP V_ M 31.07 31-26 31.46 31-65 31.84 32-03 Long-term yield security with Anti I-eT1D Technology,Ar!ti FID %leasurement tolerances P_±3%;ls�;VC,,±5%at STC:10DOV,11m7,25±2°C.AM 1.5 according to IEC 60904-3-2800w/m2.NMOT,specs:m AM 1.5 Technology',Hot-Spot Protect Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE A m(--•--- -'�''�"'�-t At least 98.5%of nominal power ----- -� �' Extreme weather rating ---' 986 1 during first year.Thereaner ma.. s, ______- __________ 023%degradation per yea,.At G : 1 j High-tech aluminium alloy frame, least 95.53%ofnomina certified for lPower W 00 high snow(6100 Pa)and wind loads(3600 Pai• up to zi,powe0 Years.up At least ;o ars.of s nominal power up to 25 years. uo 5 o as __________._____. ...-___ All data within measurement y 90 Were-Full warranties in Innovative all-weather technology a SaS aKordanhe w;th Me warranty u D terms of the Otelts sales 3 " a 10 1s m a organisation of your respective mo aoo am mo +000 - �! Optimal yields,whatever the weather with excellent low-light vEtas country. (RRADLUNCElvaa,ry and temperature behaviour. 5larama W+ms a 9uJ2n1aC r«:rw s w mmr:>,�s wan the rY9�mod„p Pertormaece�mw arao-wtce w.emns n Nonest mod;,w+ca-Y in 2021 ffi�i y2021) cnmoar5on to sre c anto-(2s-C.l000wre), The most thorough testing TEMPERxi uiti coEFFtLiENrs \W'J Temperature Coefficient of Is,, a [%/K] *0.04 Temperature Coefficient of Vm (3 [%/K] -0.24 programme in the industry Temperature Coefficient of P� 109±5.4 p y [%!K) -0.30 Nominal Module Operating Temperature NMOT Ocells is the first sofa:module manufacturer to pass the C>7 (43±3°q � most comprehensive quality programme in the industry:The new'Quality Controlled PV'of the independent certification ■Properties for System Design o institute TUV Rheinland. o Maximum System Voltage Vm M 1000(IEq/1000(UL) PV module classification Class.11 x Maximum Series Fuse Rating [A DC] 25 Fire Rating based on AN51/UL 6MO C 1 TYPE 2 8 see data sheet on real for furmer information. Max.Design Load Push/Pulp lbs/ft- 113 5400 Pa/50 2400Pa Permitted Module Temperature -40'F u to+185'F u f3 ( '] ( ) ( ) P P 6 ;see 13r condtions eccwding to fEClTS 52eca-t:2ot5,method A(-t5t)Ov,96h} Max.Test Load,push/PUIP [lbs/fY) 169(810OPa)!75(3600Pa) on Continuous Duty I-40°C up to+85°C) F 'See Installation Manual ` > DRAWN BY AH ■Oualifications and Certificates DATE 9/5/2025 F 0ua:ity controlled Pv- T c 6t2l5nland: O REVISION IEC 611n0:016 g IEC 617302016 `u This data sheet rnm lies *Cu �' t�.The ideal soltttion for. °W o p S(GI�1P,TURE watt DIN EN 5038o i Rooftop arrays on ^^ ° 21 -UL and California EnergY Comimssion(CEC)listings Pending ° residential buildings tJSA """'° PV-6 Ocells pursues minimizing paper output in consideration of the global environment RESOURCE N l�L ii,n , a,.-.loa�,ad u,1t 1.-Iii,f�,�e.mo�,�on�,.-d-Miona1- ,,d- H oeells '!n h D CELLS Am,-hu'.a00 Spectrum CC.terrov De.Sure Woo.Woo.-i CA 92618,USA I TEL-1919 7a8 59 96!EM-1 Itrr in9wryapceas corn:iYE9 wxx.aCNt1 tom DOCUMENT CONTRACTOR ELEMENT F ® ENERGY BDLARIBATTERY BACKUP 1631.779.79931E25YS.CDM v ENPHASE. IQ8MC Microinverter ELEMENT ENERGY LLC I NPUT DATA(DC) UNITS 7470 SOUND AVE, Commonly used module pairings w MATTITUCK, NY 11952, USA I +1 631 760 7262 To meet compatibility,PV modules must be within the following max.Input DC voltage and max.module 1. wModule compatibility Module compatibility can be checked at h"m://erphasecom/installers/microinverters/calculator. LIC TYPE: HOME MPPT voltage range v 25-45. IMPROVEMENT, MASTER ELECTRICIAN Operating range V 18-58 LIC NO.:67461-1-1I,52689-ME Min./Max.start voltage v 22/50 Max.input DC voltage v 60 PROJECT INFO&ADDRESS Max.continuous operating DC current A 14 _ Max.input DC short-circuit current A 25 LISA ABLEMAN . Max.module I_ A 20 6305 HORTONS LN, Overvoltage class DC port 11 SO UTHO LD, DC part backfeedcunant mA 0 NY 11971, USA PV array configuration Ungrounded array:no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS 108MC-72-M-US @240 VAC SYSTEM SIZE Peak output power VA 330 315 DC SIZE: 10.875 KW DC-(STC) Max.continuous output power VA 320 310 AC SIZE: 8.000 KWAC Nominal grid voltage(L-L) v 240,split-phase(L-L),180° 208,single-phase(L-L),120' Q8 M C Microinverter Easy to install Min✓Max.grid voltage' V 211-264 183-229 -orming-,software- Lightweight and compact with plug- Max.continuous output current A L33 1.49 defined mic'Stroinverters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency Hz 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Ht 47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire AC short circuit fault current over three A 2.70 digital logic and has superfast response times to changing loads and grid events,alleviating cabling cycles constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit 12 10 — -.r High productivity and reliability Total harmonic distortion" % <5 Enphase Produces power even when the grid is j down' Overvoltage class AC port RI { More than one million cumulative hours AC port backfeed current mA 18 of testing Power factor setting 1.0 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure P 9V Ys Grid-tied power factor(adjustable) 0.85leading...O.BS lagging IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 972 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency % 97.0 96.5 software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption row 33 25 Complies with the latest advanced grid MECHANICAL DATA UNITS support --_ � Remote automatic updates for the Ambient temperature range -40°C to 65°C(-40°P to 149°F) • latest grid requirements Relative humidity range 4%to 100%(condensing) Configurable to support a wide range DC connector type StSubli MC4 Connect PV modules quickly and easily I08 Series Microinverters are UL Listed of grid profiles Dimensions(H-W-D);Weight 212 mm(8.3")•175 mm(6.9")-302 mm(1.2");1.1 kg(2.43 Ibs) to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturer's instructions. Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure NOTE: 108 Microinverters cannot be mb.ed together with Environ.category;UV exposure rating NEMA Type 6;outdoor previous generations of Enphase microinverters DRAWN BY AH (107 Series.106 Sedes,ate.)in the same system •Meets UL 1741 only when installed with IQ System Controller 2 and 3. 10 Gateway Is required to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 profile at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and DATE 9/5/2025 Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. 0 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at o REVISION (7)No enforced DC/AC ratio. M r// se.com/trademarkvape-guidelines are trademarks of Enphase Energy.Inc.In the US and other countries. (2)Nominal voltage range can be extended beyond nominal if required by the utility. Data subject to change. 108MC-MC4-DSH-D0049-3.0-EN-US-2023-10-18 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 SIGNATURE PV-6.1 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY SOLAR I BATTERY BACKUP'631.779.7993I E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN nENPHASE. ___—_ ® Product details IQ Combiner CC LIC NO.: 67461-1-1I,52689-ME 10 Combiner 60 Includes the following Components: Up to 2•BO A breakers for batteries. 10 Gateway for revenue-grade production and storage metering. Up to 1.60 A breaker for 10 EV Charger. Combiner controller board for safety. Up tot•BOAbreakerforintegmtedloadcontroflan. PROJECT INFO&ADDRESS IQCombiner 6C IQCombiner6C° Solar shield and fans to enhance thermal performance. Aggregate PV breaker(if the combiner is installed at a readily accessible outdoor LISAABLEMAN (K-IQ-AMl-240-6C) Integrated Rapid Shutdown initiator for outdoor installs. IocationY Integrated and pre-wind current transformers for PV and batteries. OR 6305 HORTONS LN The 4fD Gornhiner 6CCo 'I ales IttEroornecibn equ)Arent nioa Rapid Shutdown initiator(options) External AC disconnect(located outdoors)installed between the lO Combiner 6C f . Enphase Mobile Connect cellular modem(CELLMODEM-07-NA). and the backfed S O UT H O LD s ng)e closure,stream4nlrg the installation o4IO Set os Mkcrol verze panel.° Integrated load controller,with monitoring and central loads. 1 It mtogra;as the lG Gatevva rocffora consistent pre-wired solution OR �+ forias'enhala 01iications.lt faclude5 broaker spaces for PV batiary, """ _"" External AC disconnect(located outdoors)on aggregate PV breakers NY 11971, USA EV'ahargar,and an integratod load c ro.?Q.Addibona .itreduces msteilaboAme with mtegrpt ared pre-w"ued current trnnsfarmers}or Cellular data plan 5-year data plan included.' Enclosure 10 Combiner 6C unit PV andbatteties. - EnphaseMobileConnect CELLMODEM-07-NAI cellular modem with a 5-year data plan. SYSTEM SIZE 240 VAC-/s2O% IO Combiner 6C accessory kit,includmglabels,control(CfRL)headers.and the 'Nominal voltage/Range(L-L) DC SIZE: 10.875 KW DC—(STC) Accessory kit quick install guide(GIG). Split-phase(1-1-1.2 ZAO V.L-N 120 V.18D'phase angle) d • AC SIZE: 8.000 KW AC Vohs measurement accuracy •,%v�ma,(•12vL-N and 24vL-u The pre-installed(60 A)UL 489-certified breaker is usable as a Rapid Shutdown � � Aggregate PV breaker initiator H the Ili Combiner 6C is Installed at a readily accessible outdoor location. 'Nominal frequency/Range 60 Hz/56-63 t1z Maximum continuous PV current BOA Key specifications X-10-AMI-240-05C lJ Smart The Integrated lO Gateway reports production and storage metering.IO EV Charger, Maximum continuous battery current 2.59A 24OVAC-/±20% and consumption monitoring,along with lO Battery and lO Mieroinverters data Maximum continuous EV charger cur rent 1.48A Nominal voltage/Range(L-L) Spth-ph as.(L,-L2240 V.L-N 120 V. integrated combiner controller IQ Gateway from the site to the Enphme Cloud.This monitoring and analysis software enables - 1807 board(CCS)and IQ Gateway. comprehensive.renmte maintenance and management of Enphase systems. Maximum continuous DER current 160A Includes Enphase,Mobile Connect ._ _ - Nominal frequency/Range 60 Hz/56-63 Hz (CELLMODEM-07-NA). The integrated DER relay isolates home loads from PV and batteries.It Maxi mum continuous current supported by 9re Y i systems fi4 A Supports flexible networking:VlrFi Distributed Energy Resource(DER)relay enables the system to automabcaiy recover the State of Charge(SoC)when the integrated load controller Maximum continuous PV current Ethernet,or cellular. BOA batteries are depleted dur on ing off-grid operati . (combined) integrated revenue-gmtle Maximum continuous backfeed current 100A production and storage metering A 100 A PV busbar(far IQ Microinverters)with support for four double-pole breakers Maximum breaker rating for PV branch circuit 20 A Maximum continuous battery current 2.59A via pre-installed current for installing lO Series Microrwaners. Maxi Maximum continuoustransformers.Also supports mum break e r rating for battery branch EVSE current 1.48A consumption and EV charger A200 A DER busbar(for PV.batteries.EV charger.and other home loads)with circuit 80A Maximum continuous integrated load 64A monitoring. DER bulbar support for four double-pole breakers for installatiom Maxim controller current /ti EasyTwoforlQ8attey1OC. Maximum breaker rating for EV charger 60A Maximum continuous Distributed ll One for Enphase EV charger. Maximum breaker rating for integrated load BOA Energy Resources(DERs)current 160 A Pre-installed UL 489 certified One for aggregate PV(integrated Rapid Shutdown Device). controller device for Rapid Shutdown. - Maximum connnuous backfeed current 100A Single-stud mountable with two Fully integrated meter with solid-core current transformer(CT).accurate up to Maximum breaker rating for backfeed 125A - .. screws. Integrated production metering (breaker located in the backfed panel) Up to 100 A(ships with 60 A pre- Supports multiple conduit entry sO.S%,ANSI C1220 class 0.5 compliant.Does not require field wiring. Maximum aggregate PV breaker size Maximum short circuit current IO kA Installed breaked` options such as top side right,top Fully integrated meter with two solid-core CTs.accurate up to e0.5%,ANSIC7220 side left•bottom side left,bottom Integrated battery metering class 0.5 compliant.Does not require field wiring. 680 mm(26.8')•460 mm(,8.19.220 side right.bottom rear•and bottom. Maximum rating for aggregate PV breaker tOD A° Dimensions(H•W•D) min(8.7') Su g two solid-core CTs,accurate up to z2.5%.Does not Supports up to five PV branches. Fully integrated monitoring using Maximum breaker rating for aggregate PV two battery circuit breakers and Integrated backfeed monitoring require field wiring. Ambient operating temperature range -40•C to 46'C(-40•F to TIM one EVSE circuit breaker. feed-in if combining branch circuits on 100 A*' Cooling Solar shield,active air cooling Bluetooth-based Wi-Fi praysioning Integrated monitoring in the built-in load Fully Integrated monitoring using two solid-corn CTs.accurate up to x0.5%.Does not external panel board fareasy W.-Fiset.p. controller require field wiring. Internal PV busbar rating 100A Supports an integrated load - controller with upto80Ausing EV charger monitoring Supports monitoring of EV charger;accuracy up to s2.5%4 Internal DER busbar rating 200A double-pole or quadplex breakers. Up to 4.20 A breakers for PV.° Breaker spaces' Auxiliary/Dry contacts 1•NO/NC(120 VAC.3A)onthe Combiner Controller Board G Ramble Up to 1•100 A aggregate PV breaker.' • Durable NRTL-eertified NEMA type •ts. ,.wa•x.ree.cum.,wwe......:o,.d«:F.nxasn„m.,.roso>:n,,,«,a-x...a..,we.e.v-a,yr. 3R enclosure. wcome,,,.ee.,o,,..�.�..,�,,,.awc-.w>ec e...•,a•,w°,w•• =vma+em,.,erxn arvu..nam.Iw.a.Nw,r<i+r.mria. c :.a•.,.m«-ca.a..-.,:,..:...v.,roe.,awe.°•.,=a.o,rocc-,..,,.r�>a.nroce•w.e,ec w.-vine,:�,..,.«.....wn..•n.=•�-x,.aaw •x,v.r;�rro:. �Pm,.r.,awmss.,K,a,,..,:.. rz ...�. .�wca.e,..sc • 15-Yearlimited warranty '^' ^^w°^�+°9^,•,•••^m�°�°•lzu,.am.svuew,.�...e••«au<ct,,.,rze.w.•.m,en,.nae..+r.-ms,romm...,,r.,r�m -u�o-.vm.acs�.-�..x.am...nm..vsx.,.wrw.a�,,.w,•.cm.+wwo-..ram..,:..wro:n.aca.w,..ti,w,;..sc,rmwi.ba,mm.w;T,-s.e,e;. ,.c««w-na ern.,r.n..a:.,.,•.rw.,r�.�+n,«e.:m.r.m.-wa we...mmma,e,o+w•,co.�an rm n*.m..mmc.,;a in.w.<.,,oa..u.e„n.a«a. u,.a•....a+wsr.,m.,-,ezamracv.rocorzotir.ee.,<bw..,++•sh..wwaeol.A«am,m - ` n'e°e. `wow�.a.;,,,..•e.w�wem.,,°',. v.•+•,.;=.r..,w�,wn>v�..m,.m.w,..+.amw«,.....,.a.�..raaw.F..t*�.,M:,.eee.., •�n+ w.,.°m we...w.,..•a,"..=an'»oa.L,a....,.no�w.ew,n...<.s.x.me..ate m.,,w,m.rm.wnroom.w�m.,wro,=arnww+er+«a.m... •w w....son,.«ev.rn.>,e. .m..avwwae«tsn:.-x .an.u..�r.,n.vaeoam«r.n.,vr.s,vwo-.w...•o-.•...,.cum+w.w<,.•a•,«•,.no.,ocean.sec..,.,.xam.,m..>n.,va•w.o-wd..r.u..n.m. r.owm,�+sm.c,..s.,,. w a,Mso.m«...a.m w�w�„e Me.ca•s•wow,...,,,.,-n,.,.a<.a,rm,.xw•m«....o..an•.-.rn..�.v,> .ca sn�uumnt..ur. „eo-ra,eah,o:k.amwn,4wm.aeu.,ro,an we cc fw�c.«-.......:b a.>,«., an.m:.s.a:»:ass..... u� one ro•�.sir.uz:.v T �.=`,:......�. +o�xm9•,..�.,., :.-..uc.m, .,.,.�,....,..o.�.k,�w.,. avawn_ry roe DRAWN BY AH DATE 9/5/2025 REVISION SIGNATURE PV-6.2 RESOURCE DOCUMENT CONTRACTOR ELEMENT Aw IRONRIDGE Al Aire Rail ENERGY SOLARI BATTERY 13ACKUPI631.779.79931 E25YS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME SEE DESCRIPTION IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO&ADDRESS ' 1 ' LISA ABLEMAN 6305 HORTONS LN, SOUTHOLD, ITEM NO DESCRIPTION QTY IN KIT NY 11971, USA 1 AIRE RAIL, Al, BLACK(OR CLEAR), 170" 1 SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC PART NUMBER DESCRIPTION AE-Al-170B AIRE RAIL, Al, BLACK, 170" AE-Al-170M AIRE RAIL, Al, MILL, 170" 1) AIRE Al RAIL SECTION PROPERTIES 1.40 PROPERTY VALUE -+1.17� TOTAL CROSS-SECTION AREA 0.364 in' SECTION MODULUS (X-AXIS) 0.146 in' MOMENT OF INERTIA (X-AXIS) 0.126 in 1.138 1.04 1.70 MOMENT OF INERTIA (Y-AXIS) 0.114 in TORSIONAL CONSTANT 0.001 in 0.22 POLAR MOMENT OF INERTIA 0.239 in4 PART NUMBER MATERIAL FINISH DRAWN BY AH AE-Al-170B 6000 SERIES ALUMINUM BLACK DATE 9/5/2025 AE-Al-170M 6000 SERIES ALUMINUM CLEAR REVISION SIGNATURE v1.10 PV-6.3 RESOURCE DOCUMENT CONTRACTOR ELEMENT do ENERGY SOLARI BATTERY BACKUP I fi31.779.79931 E2SYS.COM . IRONRIDGE End Fastening Object AML IRONRIDGE Universal Fastening Object® ELEMENT ENERGY LLC 7470 SOUND AVE, Only for installation and use with IronRidge products in MATTITUCK NY 11952 USA accord with written instructions see IronRidge.com/UFO +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN e LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO&ADDRESS LISA ABLEMAN 6305 HORTONS LN, UNIVERSAL FASTENING OBJECT` SOUTHOLD, NY 11971, USA PART NO. DESCRIPTION UFO-END-01-Al END FASTENING OBJECT(END CLAMP,30-40mm),MILL SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) UFO-END-01-B1 END FASTENING OBJECT(END CLAMP,30-40mm),BLACK AC SIZE: 8.000 KW AC 1 .43 �l.o� ITEM NO. DESCRIPTION UFO CL-01-A1 UNIVERSAL MODULE CLAMP, CLEAR 1.27 COMPATIBLE WITH .56 30-40mm MODULE I FRAMES 2 .29 �7/16"Head I 39 .61 •25 COMPATIBLE WITH Uc C� 37 30-46mm MODULE FRAMES 43 1.12 1.0 7/16"HEAD .97 O .25 Property Value ITEM NO. MATERIAL FINISH Material 300 Series Stainless Steel 1 6000 SERIES ALUMINUM MILL OR BLACK Finish Clear and Black 2 300 SERIES STAINLESS STEEL CLEAR AND EEK7:1 DRAWN BY AH DATE 9/5/2025 V1.0 0.32 REVISION SIGNATURE PV-6.4 RESOURCE DOCUMENT CONTRACTOR ELEMENT A Ej 11 ENERGY SOLAR 113ATTERY 9ACKUP I531.779.7993I E25Y5.COM _A. IRONRIDGE Bonding Hardware AAL IRONRIDGE Grounding Lug ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME 3 3 1 IMPROVEMENT, MASTER 2 ELECTRICIAN 1 3 LIC NO.: 67461-HI,52689-ME ® ® 2 PROJECT INFO ii<ADDRESS LISA ABLEMAN ITEM NO. DESCRIPTION 4 6305 HORTONS LN, 1 BOLT,T CSTM,3/8-16 SOUTHOLD, 2 BOLT,BONDING 3/8-16 SQ HEAD ITEM NO. DESCRIPTION NY 11971, USA 3 NUT,BONDING STEP 1 LUG,GROUNDING,LAY-IN-LOW PROFILE 2 BOLT, 1/4-28 X.750"HEX CS SST SYSTEM SIZE BONDING HARDWARE 3 NUT, FLANGE HEX 1/4-20 SST DC SIZE: 10.875 KW DC-(STC) 4 BOLT,T CSTM 1/4-20 X 1.188"LOCK SS AC SIZE: 8.000 KW AC Part Number Description BHW-TB-02-Al T-BOLT,BONDING HARDWARE Part Number Description Wire Size Range(AWG) i BHW-SQ-02-Al SQUARE-BOLT,BONDING HARDWARE XR-LUG-03-Al GROUNDING LUG,LOW PROFILE 4-10 1) BOLT, T CSTM, 3/8-16 2) BOLT, BONDING 3/8-16 SQ HEAD 1)Lug, Grounding 3) Nut,Flange Hex 1/4-20 82 1.00 1.00IUL� .63 I 3/8-16THD 1 •63 71 1/4-20THD �•59 C� .38 � 56 W 1 0.26 7/16'Head .24 .29 � 3/8-16 THD7 IIL-1.75--� Property Value Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Material Tin Plated Copper Finish Clear Finish Clear Finish Clear Matte 4) Bolt,T CSTM 1/4-20 x.750 3) NUT, BONDING STEP _J_ .24-'-I 1/4-20THD 3/8-16 THD 2) Bolt, 1/4-28 x.750 Hex I 61 b Head 1/4-28THD 75 .75 I I 7/16"Head:] .79 Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear DRAWN BY AH Finish Clear DATE 9/5/2025 v1.30 v1.10 REVISION SIGNATURE PV-6.5 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERray = SOLAR eATTERY BACKUP 1&31.779:79931 E2SYS.121314 IRON RIDGE UFO' Family of Components System Diagram ELEMENT ENERGY LLC 7470 SOUND AVE, - MATTITUCK, NY 11952, USA +1 '631 760 7262 Simplified Grounding HOC Every Application _ _ _ _ _ _ _ _ _ __ _ - - - - - - LIC TYPE: HOME IMPROVEMENT, MASTER The UFO®family of components eliminates the need for ELECTRICIAN separate grounding hardware by bonding solar modules ^� _ LIC NO.:67461-HI, 52689-ME directly to IronRidge'XR Rails'.All system types that feature the UFO®family—Flush Mount',Tilt Mount'and Ground Mount'—are fully listed to the UL 2703 standard. _ _ _ _ _ _ _ _ PROJECT INFO&ADDRESS - - : - - - - - - - - - - - - - - = - - -- - -- -®_ - - - = - - - - - - - - - LISAABLEMAN UFO'hardware forms secure electrical bonds with both the module and the rail,resulting in many parallel grounding O S LN, 6305 HORT N paths throughout the system.This leads to safer and more SOUTHOLD, reliable installations. NY 11971, USA Only for installation and use with IronRidge products in accord with - - - - - - - - - m written instructions.See IronRidge.com/UFO SYSTEM SIZE DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC Universal Fastening Object(UFOS) Stopper Sleeve The UFO^securely bonds solar modules to XR _ _ �`— — — — — - - - - - - - — Y The Stopper Sleeve snaps Rails.It comes assembled and lubricated,and '' � _ _ _ _ _ _ _ _ _ _ _ onto the UFOs,converting it can fit a wide range of module heights. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _m_ _ into a bonded end clamp. t - - - - - O UFO Stopper Sleeve 0 Grounding Lug m BOSS" Splice Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the ejf / same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. UL Certification b E @ TPA f_ The IronRidge Flush Mount', Tilt Mount,and Ground Mount XR Rails ./ ./ XR100&XR1000 C BOSS'Splice ' " , Systems have been listed to UL Bonded Structural Splice � i r 2703 by Intertek Group plc. UFO/Stopper d .i connects rails with built-in t BOSS'S lice .d N/A bonding teeth.No tools or ti P hardware needed. j �` 1� UL 2703 is the standard for i evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters will maintain strong electrical and &Power Compatible with most MLPE manufacturers. Grounding Lug mechanical connections over' Refer to system installation manual. � Optimizers A single Grounding Lug Bonded Attachments Pry connects an entire row The bonding bolt attaches an extended period of time in of PV modules to the and bonds the L-foots to the extreme outdoor environments. Fire Rating Class A Class A NIA DRAWN BY AH -"" -- — — grounding conductor. rail.It is installed with the Tested or Evaluated with over 400 Framed Modules DATE 9/5/2025 same socket as the rest of the Modules system. -� Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. REVISION SIGNATURE PV-6.6 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY SOLAR I BATTERY BACKUP I fi31.779,7993I E25Y5.COM ELEMENT ENERGY LLC AML IRONRIDGE QuickMount° Halo UltraGrip 1.Halo UltraGrip 38 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS —RD STRUCTURAL SCREW PN RD-1430-01-M7 3.35 LISA ABLEMAN SOLD SEPARATELY � SHOWN FOR REFERENCE 6305 HORTONS LN, SOUTHOLD, NY 11971, USA Release Liner SYSTEM SIZE shown for reference DC SIZE: 10.875 KW DC-(STC) AC SIZE: 8.000 KW AC 3.83 CD o � —�.40 �-- 0.26 1.63 1.56 I ITEM NO DESCRIPTION QTY IN KIT 1 QM Halo UltraGrip(Mill or Black) 1 O O .34 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black 3.00 Property Value Material 300 Series Aluminium Finish Mill or Black Q DRAWN BY AH DATE 9/5/2025 ®2022 honRidge.Inc.All rights reserved Visit—va-patents.com for patent inlomtation. CM-HUG-01At o;CM-HUG-01-Mt Cut Sheet Rev 1.0 ®2022ImnRidge,Inc.All rights reserved.Visit vnv u-patenls.com for patent information. 01,1-HUG-01-Bt or GM-HUG01-Ml Cut Sheet Rev 1.0 REVISION SIGNATURE PV-6.7 RESOURCE DOCUMENT CONTRACTOR ® ENERGY S13LARI BATTERY BACKUP 1631.779.79931 EZSYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, hak IRONRIDOE QUIckMount" RD Structural Screw MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER 1 ELECTRICIAN 2 LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS LISA ABLEMAN 6305 HORTONS LN, SOUTHOLD, NY 11971, USA SYSTEM SIZE ITEM NO I DESCRIPTION QTY IN KIT DC SIZE: 10.875 KW DC-(STC) 1 Self Drilling Screw,#14,Wood Tip 1 AC SIZE: 8.000 KW AC 2 Washer,EPDM Backed 1 PART NUMBER DESCRIPTION HW-RD1430-01-M1 RD Structural Screw 1.Self Drilling Screw,#14,Wood Tip 5/16"Head •22 #14 DIA 0.43 i77!77! Property Value Material 300 Series Stainless Steel Finish Clear 2.Washer,EPDM Backed .13 �— 0. 66 Q 0.57 Property Value Material 300 Series Stainless Steel DRAWN BY AH Finish Clear DATE 9/5/2025 Q 20221ronRidge,Inc.All rights reserved.Visit—ir. patents.com for patent information. QM-HW-RD-143M1-MI Cut St-1 Rev 1.2 REVISION SIGNATURE PV-6.8 RESOURCE DOCUMENT CONTRACTOR U��A ® ELEMENT ENERGY SOLAR BATTERY BACKUP 1631.779.79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER � ENPHASE. aan=..^^Eastcczsz:� Order code: . ELECTRICIAN Name IQ BatterylOC Dim ensions(H•W•D) 621mm•708mm•362(24.5in•28in•14.4in) LIC NO.: 67461-1-1I,52689-ME The lO Battery IOC system with two 5 kWh battery units having integrated Maximum lifting weight 57 kg(125lb) Description IQ Microirwerters(SKU:IQ8BL.1088N)with a battery management system(EMS) Total installed weight for 144 kg(317 lb) �Q Battery ©Ci as part oflQBLMicroimterters _ PROJECT INFO&ADDRESS Enclosure Outdoor-NEMAXI Limited vfarranty LISA ABLEMAN The QBa i'1rV too ffi-trrala AE-cotlp'k?.d systt(n is Compact.(xoyvarftii, Cooling Natural convection * IQ Battery10Cunit 60%capacity,up to 15years,or6,000cycles' AlMude U to 6305 HORTONS LN rdlabla and save i#as a told usakt)e capacity IQ-O k VFt aid inelerdr~7 P , 're ed rd-- trirtg VaRers' ha 7.@B IiVA cul2irnroUs 'uOutput(AC-) .e Wall-mount or pedestal-mount(sold separately) SOUTH OLD, poyrat atkr�l8pra' s C--pa ky andins lets tart gtack)y �„4a HASE Mounting L desFgn titargh sy2em 5t2tSo meat the CUstonnters needy Rated(continuous)output power 7.08 kVA• 1-Features and compliance NY 1197 A Nominal voltage/range -- - - - �240/211-264 VAC- - _ - s c = Compatible with IQ and M Series Microimrerters,IQ Meter Collar,IQ Combiner 6C. Nominal frequency/range 60/57-63 Hz Compatibilityand lQ Gateway for grid-tied and backup aperetiorts. Rated output current(@240 VE-LAC-) 29.5 A' Communication Wired control communication SYSTEM SIZE Rated nuebal current(@240 VE.NAC-) 24 A' Services Backup,Self-Consumpticn.TOU.and NEM integrity DC SIZE: 10.875 KW DC-(STC) w ° -„1- +"•' �` Peak output 56A(threeseconds),44.8A(tenseconds) Morutorin En phase haseA g p integration AC SIZE: 8.000 KWAC pu t g p p pp monitoring options:APlint ration Power Stan capability Up to 90 A LRA° CA Rule 21(UL 1741-SA).IEEE 15472018(UL 1741-BB.3rd Ed.)CAN/CSA C222 No. Power factor(adjustable) 0.85leading_.0.85 tagging 107.1-16 Key specifications • C)Powerful - - - - - Compliance(pending) UL 9540-.UL 954CAu,UN 38.3,UL 199B.UL 991.NEMA Type 3R,AC156 EMI:47 CFR. Rated(contlnuous)output power 708 WA' Maximum conductor sue supported 3 AWG Part 15,Class B.ICES 003 @ Provides 14.16 kW,peak power 40 A OCPD,requires a minimum of 8 AWG for one IQ Battery 10C Cell module:UL 1973,UN 38.3 Rated ou tout current( 240 Ve AC-) 29.5 A' Includes(our embedded Inverters:UL 62109-1.IEC 62109-2 Overcurrent protection device(OCPD) or Rated mutral current(@120 VE.0 AC-) 24 A! 1088 Microinverters 80 A OCPD.requires a minimum of 4 AWG for two or more 10 Battery IOC' finereonnection Sing;"hase Most powerful mieroinverter with ... .: e up to 2,l kVA continuous power Interconnection Single-phase Nominal votage 120/240 VAC- There are a total of three boxes;two boxes contain the 5.0 kWh battery units and the third box contains the IQ Battery IDC corer kit RellaNe AC round-trip efficiency' 90% Nom:ral frequency 60 HZ 5.0 kWh battery Unit(80SCOI-USOO-13) Cools Passively with no moving Battery_ _ units Two 5.0 kWh battery Battery IOC er _ parteorfans units o flQ Bette Usable capaGtq t0.0 kWh' Ambiemopatmgtempera lure range -20•C to 50•C(-4•F to 122•1 Uses wired communication for fast Total capacity 10.0 kWh Mounting bracket Two mounting brackets for mountingthe batteries on the wail __.___ {charging)' Non-contlensing and consistent connection Usable capacity' 10.0 kWh Saismib screws Four seismic screws for securing the battery unit on the mounting bracket - - - Updates software and firmware _ _ Ambient operating temperature ra eratunge -217C to 55'C(-4•Fto 131•F) remotely DCround-Vi efficiency96% P _ Twelve ME hexagonal_Phillips screws with_ washers for mounting second wail bracket (dichwgirg)' Non-condensby Mounting bracket fasteners Chemistry Lithium iron phosphate(LFP) L/Simple Nominal DC Voltage 76.8V on pr6installed battery unit wall-mountor pedestal-rrwent(sold Fully integrated AC Battery system Maximum DC voltage 86.4V Drill template Two drill templates to mark drilling points and conduit entry locations on the wail Mounting separately) with neutral forming capabilities _Q Battery 10C cover lit(BAG-NC J Installs and commissions easily • Ambient operating temperature range -20°C to 50°C(-4'F to 122°F) ) • Offers homeowners remote (charging)" non-condensing Cover One cover for IQ Battery tOC Product dimensions e•• monitoring and control from the - -- - --' - - -- One i I. _. 6„ 9 Ambient operating temperature range -20°C to 55'C(-4'F to 731'F) One Interconnect power cable assembly for internally connecting two battery units Enphase App Interconnect power cable .� (discharging)` non-condensing -- -- - of lO Battery IOC Fleld replaceable components ___ _ _ _ ___ _ _ _ __ • t_ r Optimum operating temperature range O°C to 30°C(32°F to 86'F)c con control cable assembly t--� One inter nett con Ice eassembl r internally connecting two battery units I+s- O Spy - - - - - -- - - - -Chemistry Li[hfum iron phosphate(LFP) Interconnect control cable o Battery 9 one Pl blf lO B IOC having reinstalled control connector(without resistor)at one z19• l e-.,, -I 1 t5 i I �"��: 1' Evaluated to UL 9540A.the highest - and •���• `r` _" 1 industry standard for battery safety 25• 141 Control connector with resistor One spare control connector with resistor for control xnnng Uses LFP chemistry for maximum �j�- safety and longevity _ Raceway adapter Two raceway adapters for routing cables internally between two battery units �e nrern°raaan ma.wamremm,°pa. - s•cwrraa.,xmaaf-mr�+mammtncrc-a�w..ac.m,. Cable holder Two cable holders for cable management in wiring compartments Em.reabcd va,W.°wrgxum•w N••-o Rncb+•,o-.i.m.Imuh..P.u,,.,aeeb e•aeora.,.,e. •,.09 WAIa5tfmf`a^aarraed]COv.�lanCr. •A rM l'.uu�alarc.4b•°a r>r�uvicerm[eb„mm JSA3.Ov t�1mh. Conduit covers One left side and one right side conduit rovers to close unused conduit openings �mw rvrmrtoca.<awe•.wncru«canwao�rrn•r.aa.,t..recwe,u...asr�ws.n•'ro.....m,o.vr.,n. _ _ _ - _. nerr mac n sas.°ar aws. :ahusaNeuaacLr•rs[uuba[v mR•rn(aronclM1ye4nrwm•ldtif aem.TrouaW capacrtYm-')+dna u'ery crt✓vnvrtd Ta'.n•r ukywrda a:'ammetr4o•+•]°•9r'brrrwe Farm. .ma-dua:mq'bo�*age nna�oN 33twm!vi•memu,dfwvnwydsfrneeirenancn nrvye.Pe mMr:l•++r:1'a:a'Yg6attr ow+npbcalu+wna.reao•ae.�6 FCoa'aeatbnele•Y<u pvaga)u u+wnmubcamnu>,vn M°ernFi'enri nuoawrv..6ry vro.nM-3epm55T!-aSmlltn cavow.ge •t+,tgKb rnaury.uee.tna em:aa•eSugyq ud VMcureraa m1[ weut •' Wsbo°e•J'C nnf�Aprfam•�exew•erM RC b+S•C(mirolrJ'nwMaeAwq+rpaM.,eMSCto ItlCNt'r re V3'nwhre 6aero•g.q a�M cuar,n C.cvrgvgp,�.oe rF•caare Lab aaP.eepC °ieJaeebrbrnNruvmvlearx;a,atiwrmanrxe[mpeeoen6raxaa•eQaalnre2i WC aJxeJ.t2o7ffC'M'.1],nra ZM1M➢n EJ]IS]:aMofSrtlbna° °yephrp 3n Eatrery m rya rmgerewrer•rpom••insestFa[vnuYM1le- •vvr++-atgnmNucuo+a oMbca�codr aMrapmerm!atl M aNrmLLY WrmpAmCietenl?rtr)wm.nnaZ,g W Enpn•mErcrgr Sritem ue'.abee[wnwvct,5wauavanm�e-n.asr.a�aei c.e��e-snx wu•umv ao+mv nu•M•ur°du..n rr..r,mfelx°o_zY3mro [bu ttunaJn in➢eT'.ru.n LS..tnSv-i Pie mxSm.ro DRAWN BY AH DATE 9/5/2025 REVISION SIGNATURE PY-6.9 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY SOLARI BATTERY BACKUP 1631.779.7993 I E25YS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN Ea ENPHASE. LIC NO.: 67461-HI, 52689-ME Order code MC-200-011-V01 Control connector 4-wire signaling with 24 VDC power supply between system components Manual override lever Manually sets MID relay state.Pull to open the MID relay,push to close the MID relay IQ Meter Co lar QMeterCdar Meter collar adapter wuhmcrogridinterconnectdevice(MID) Shortpress(7-10seconds):Disablesthefirtnware control of MID,toggle again to PROJECT INFO&ADDRESS r • i enable firmware control of MID Sealing Seal ring to prevent tampering or unauthorized removal of the utility watt-hour Pushbutton Long press(AS seconds):Hard reset of the unit The relay state does not change LISA ABLEMAN meter The relay LED and the control LED blink sinwitaneously for 6 seconds,indicating a q IQ Met ColtarTs trletar Socket adapter w)lh an integrated micrtxgri successful hard reset. 6305 HORTONS LN v+tercerneci°ar:d Mh7)avid energy mete`.1:a instaged rns an AAiSi Plastic bagPlastic bag for Installers to hang the 10 Meter Collar next to the utility watt-hour s Ct2F 2S $mcL-et-IQ Mit7wCella rted IF,',200Acwrtinuwzs mete, RELAY LED CONTROL LED SEATIE asr9-.1h7:an belr: either at Lire service entrance Datwoerl an ANS1 Quick install guide(OIG) IQ Meter Collar quick install guide RED RED MlD closed CYL Form 25 tr met and the meter,sac eta on the load stale cr ule _ _..- .--_ _ ..- _ _ __ _ _ ." __ NY 1 1 97 , SA __ 1 U ut.ity.--nee&a separat meter socket Pan. Accessorieskit One control connector one junction box sub-assembly:two cable glands,1/2'NPT RED Blinking second ON.l second MID ticked c)osed. (national pipe taper thread) OFF) firmware control disabled Blank cover plate One blank cover plate attached in front of the lQ Meter Collar RED OFF MID closed,error SYSTEM SIZE �. .NXx + OFF RED MID open DC SIZE: 10.875 KW DC-(STC) s s Nominal grid supply 120/240 VAC/180'.s It h e OFF Blinking(lsecontl ON.lsecond MIDlockedopen.ffrnavare n• c: ,I. 3, � )Wy p, pas Light-emitting diodes OFF) control disabled AC SIZE: 8.000 KW AC Nominal frequency 60 Hz - Nominal power consumption 3.8W Fast bfnking(025 Fast blinking(0.25 seconds seconds ON,025 ON.0.25 seconds OFF) Hard reset successful •' ' ' O Easy to InntaO power consumption 2.5 W to 5.8 W seconds OFF) Nominal grid supply 120/240VAC/160,split-phase - -- -" - - - --- - - -��-�-���� � .- � .�.��� �-- -.- -.- -..- Lightweight and simple to install Overvoltage category Category IV(service entrance-rated) OFF OFF No supply Nominal frequency 60 Hz - - - - - F . • tourers the cost of whole home Integrated consumption meter z0.5°'%accurate Fast blinking(0.25 seconds - OFF MID open.error Nominal power consumption SAW backup - � ON,0.25 seconds OFF) • Remote commissioning saves Maximum continuous current rating 2DOA Overvobage category Category IV(serviice entrance-rated) additional truck roll Slow blinkingsecond ON,3 Maximum short-circuit current withstand' 22 kA OFF seconds OFF) MID open.grid present Integrated consumption ✓Robust and reaable meter a0.5%accurate G Maximum-rem protection device 200A _._. Thermal management minimizes Maximum continuous current 200A use of internal fan One junction box assembly including two cable glands,one control connector,one rating Integrated AC-DC power supply Dimensions(L W.D) 6.9 in 8.1 in•5.0 in(175 min•206 ram°126 mm) ACC-MC-200 plastic bag,and one seal ring closes MID to restore povrerto Mrrentwtaximum hstand wit 22 kA the home he.the utility grid is Weight 3.6 lb 0.63 kg) JC-MC-200 Jumper cover suitable for up to 200 A meter socket current withstand available.even if batter y energy is Meter and meter socket interface ANSI Form 25,200 A nngless.or ring type MP-MC-200 200 A dngless meter socket Maximum overcurrem exhausted - - - 200A 15-ear roductwarrant Cooling Forced convectiorrcooled CTRL-SC3-NA-01 Control cable.500f1 spool,18/4 TC{R protection device - Y P Y Weight 3.6lb(1.63 kg) Ip Smart grid-ready Meter and meter socket Complies with advanced grid Ambient temperature range -40'F to 122'F(-40'C to 50'C) Limited warranty 15 years interface ANSI Form 25,200 A,ringlets•or ring type support,voltage.and frequency Enclosure environmental rating Indoor/Outdoor.NEMA type 3R Enphase,equipment compatibility ride-through requirements Supports remote firmware updates Maximum altitude 8200 11.(2.500 m) IQ Gateway ENV2-I0-AMI-240.ENV-I0-AMI-240 to changing grid requirements _—. "..__-_.___-_ .._ _... _.__ _.._.. ... _. -... .......".-.____.._. _._.....-.... Configurable at commissioning Communications Kit COMMS-KIT-02 to comply with applicable grid Safety UL 414 M-oinverters IQ8.I07.106 Series Microinvortem Interconnection parameters - Meets CA Rule 21(UL 1741-SA). Emissions CFR 47 Part 156 0 IQ Battery 5P(IQBATTERY-5P-IP-NA),10 Combiner 5/5C((-10-AM)-240-5, IEEE 15472 Enphase Energy System 3. 018(UL 1741-SB),Puerto X40-AMl-5C).IQ System Controller 3M(SC200D111CMClUS01) Rico Electric Power Authority _ (PREPA),and Hawaiian Electric 10 Battery 10C(IQBATTERY-IOC-IP-NA),IQ Battery 10CS(IOSATTERY-10CS-1P- industries(HEI)SRDV20grid Grid UL 1741 SA/SB(IEEE 1547:2018).multi-mode Enphase Energy System 4.0 NA).and lQ Combiner 6C(X-10-AM1-240-6C) profiles Power control system(PCS) Current sensor for a power control system under UL 3141 Third-Party Inverters and legacy Enphase Supported with fourth-generation Enphase Energy System trricroinverters DRAWN BY AH DATE 9/5/2025 REVISION SIGNATURE PV-6.10 RESOURCE DOCUMENT CONTRACTOR ELEMENT ENERGY Product data sheet ® SOLAR BATTERY BACKUP1631.779.79931 E25Y5.CDM Spec'Tiwtions _ - Short-Circuit Protection 10A cartridge fuse gG ENIIEC 60947-5-1 ELEMENT ENERGY LLC [Ith]Conventional Free Air 10A ENIIEC 60947-5-1 7470 SOUND AVE, Harmony, yellow control station, Thermal Current red mushroom head push button, [Ui]Rated Insulation Voltage 600 V 3)EN/IEC 60947-1 MATTIT 11952, USA . 1 631 760 7262 40 mm push pull, 1 NC [Uilm�p9 Rated Impulse Withstand 6kV ENIIEC 60947-1 LIC TYPE: HOME [le]Rated Operational Current 3 A 240 V,AC-15,A600 EWIEC 60947-5-1 IMPROVEMENT, MASTER XALK198H7 6 A 120 V,AC-15.A600 ENIIEC 60947-5-1 ELECTRICIAN 0.1 A 600 V.DC-13,06DO ENIIEC 60947-5-1 027 A 250 V.DC-13,0600 ENIIEC 60947-5-1 LIC NO.: 67461-Hi, 52689-ME Product availability:Stock-Normally stocked in distribution 0.55 A 125 V.DC-13,0600 EWIEC 60947-5-1 facility 12 A 600 V.AC-15.A600 ENIIEC 60947-5-1 - Price*: 119.63 USD Electrical Durability 1000000 cycles,AC-1 5.2 A 230 V 3600 cyc1h 0.5 ENIIEC 60947-5-1 appendix C PROJECT INFO&ADDRESS 1000000 cycles,AC-1 5.3 A 120 V 3600 eyc/h 0.5 ENIIEC 60947-5-1 appendix C LISA ABLEMAN 1000000 cycles,AC-1 5,4 A 24 V 3600 ayclh 0.5 ENIIEC 60947-5-1 appendix C Main Range Of Product Harmony XALK 1000000 cycles.DC-13,0.5A24V36DOcycih0.5EWIEC609475--1 appendix C 6305 HORTONS LN, Electrical Reliability A<10exp(-6)5 V,1 mA ENIIEC 60947-5-4 SOUTHOLD, Product Or Component Type Complete control station A<10exp(-8)17 V,5 mA EWIEC 60947-54 NY 11971, USA _ Device Short Name XALK Product Destination For XB5 0 22 mm control and signalling units ` sEnvironment SYSTEM SIZE Control Station Application Emergency stop functions Protective Treatment TH DC SIZE: 10.875 KW DC-(STC) Emergency switching off function 3 Ambient Air Temperature For 4o...1s6°F(-40...70•C) AC SIZE: 8.000 KW AC Colour Of Base Of Enclosure light grey RAIL 7035) Storage Ambient Air Temperature For -40...158•F(-40...70°C) Colour Of Cover Yellow RAL 1021) Operation Material Potycarbonate Overvottage Category Class 11 IEC 60536 S Operator Profile 1 mushroom head push-button - Ip Degree Of Protection IP66 IEC 60529 IP67 Operators Description Red unmarked 1 NC IP69 d IP69K Reset Push-pull - .m Nema Degree Of Protection NEMA 13 Control Station Composition 1 mushroom head 0 40 mm push-button,red 1 NC unmarked a NEMA 4X Contact Operation Slow-break Ik Degree Of Protection IK03 EN 50102 Standards ENIIEC 60947-5-1 Complementary _ CSAC22.2 No 14 UL 508 Cable Entry 1 knock-out for cable entry 0.00...0.55 in(0...14 mm) t IEC 60364-5-53 2 knock-outs for Pg 13 cable gland and ISO M20 0.00...0.47 in(0...12 mm) a EN/IEC 60947-1 Tapped entry 2 JIS C 4520 ENIIEC 60947-5-4 Net Weight 0.401b(US)(0.183 kg) $ ENIIEC 60947-5-5 Resistance To High Pressure 1015.26 psi(7000000 Pa)131•F(55'C)0.1 in Product Certifications CSA Washer g UL Listed Positive Opening With EWIEC 60947-5-1 appendix K " 5 - Vibration Resistance 5 gn 12...500 Hz)IEC 60068-2-6 Operating Travel 0.06 in(1.5 mm)NC changing electrical state) E' 0.17 in(4.3 mm)total travel) Shock Resistance 30 gn 18 ms)half sine wave acceleration IEC 60068-2-27 50 gn 11 ms)half sine wave acceleration IEC 60068-2-27 Operating Force 50 N Mechanical Durability 300000 cycles Ordering and shipping details Connections-Terminals Screw clamp terminals.<-2 x 1.5 ram'with cable end ENIIEC 50947-1 Screw damp terminals,—1 x 0.22 mm'without cable end EWIEC 60947-1 Category 22475-WALL STATIONS Tightening Torque 7-08...10.62 Ibf.in(0.8...1.2 N.m)ENIIEC 60947-1 Discount Schedule CS2 Shape Of Screw Head Cross Philips no 1 Gtin 3606480669D33 Cross pozidriv No i Slotted flat 0 4 mm Returnabitity Yes Slotted flat 0 5.5 mm DRAWN BY AH Country Of Origin CZ Contacts Material Silver alloy(Ag/Ni) DATE 9/5/2025 Packing Units REVISION Price is"List Price'and may be subject to a trade discount-check with your local distributor or retailer for actual price. SIGNATURE Dec 28,2023 �,•. a, s< ;:deg , 2 r,>n�,:� s`'�tF.'ae� Dec 28,2a23 PV-6.11 RESOURCE DOCUMENT