Loading...
HomeMy WebLinkAbout52281-Z ho��oF souTyolo Town of Southold * P.O. Box 1179 53095 Main Rd UNV N Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46721 Date: 12/09/2025 THIS CERTIFIES that the building HVAC Location of Property: 2345 Bavview Ave Greenport, NY 11944 Sec/Block/Lot: 52.-5-1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 09/02/2025 Pursuant to which Building Permit No. 52281 and dated: 09/22/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: HVAC system to an existing single-family dwelling as applied for. The certificate is issued to: Byrne TM Revoc Trt , Kaliski V Revoc Trt Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114225 11/11/2025 PLUMBERS CERTIFICATION: Aut rized Si t , �o�aofso�Tyo`o TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE 00U"r SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52281 Date: 09/22/2025 Permission is hereby granted to: Byrne TM Revoc Trt 2345 Bayview Ave Southold, NY 11971 To: install HVAC system to an existing single-family dwelling as applied for. Premises Located at: 2345 Bayview Ave, Greenport, NY 11944 SCTIVI# 52.-5-1 Pursuant to application dated 09/02/2025 and approved by the Building Inspector. To expire on 09/22/2027. Contractors: Required Inspections: ELECTRICAL- ROUGH, PLUMBING , ELECTRICAL- FINAL, FINAL, Fees: HVAC $250.00 CO-RESIDENTIAL $100.00 Total $350.00 — Building Inspector Inspector NASSAU ELECTRICAL; is t; SUFFOLK INSPECTORSI 159 Route 25A,Building 1 Suite B <1 Miller Place,NY 11764 Telephone:631 495 8136 ? Fax:631 509 4538 ? E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Element Energy LLC Certificate No.: 114225 Rough In Inspection Date: Final Inspection Date: Nov 11,2025 Application No.: Building Permit No.: 52282+52281 l County Tax Map No.: 1000 052.00 05.00 001.000 LIPA Solar App No.: PAM-2025-391754 d This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described !! below, installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: R Owner: THOMAS M.BYRNE Site Location: 2345 BAYVIEW AVE,SOUTHOLD,NY 11971 Owner's Address(if different): F I x]Residential �x Indoor Basement Service Shed ❑Commercial Qx Outdoor First Floor Pool Hottub ❑New Renovation Second Floor Attic/3rd Floor Garage I I Addition Survey PV Solar Generator Conversion ❑Signs Battery Storage Other: I INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture Dual Func Breaker 1 Three Phase Hot Water GFCI Recpt� Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt� LED Lighting Smoke CO Combo Transformer Appliance CktO Dryer Recpt� Emergency Time Clock I Disconnect Switches Twist Lock O Exit Fixtures 0 Pumps GFCI Breaker Heat Pump r_-� Electric Heat 0 Pool Luminaire Exhaust Fan 0 a Other Equipment:System Size:14.88 kW r]ty:35 Desc:EAGLE JINKO JKM425N-54HL4-B Oty:35 Desc:Enphase IO8MC-72-M-US/2-outdoo'AC`compressors The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Element Energy LLC License No.: 52689-ME I Date Printed: Nov 11, 2025 j Q Inspected I i Signature: �I �o�aOF SOUTyo� a # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ vy"FINAL f-A446 [ ] FIREPLACE & CHIMNEY [ ' ]: FIRE SAFETY INSPECTION ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR TOyVN OF SOUTHOLD - BUZLDEN"G DEPARTMENT Town Hal, Annex 543 75 Main Road P. O. Box 1179 Southold. Ny 11971-0959 Telephone (631 ) 765-t -2 Fax (631) 765-950'_' i - Cate Received APPLICATION FOR BUILDING PERMIT p For Office Use Only E C PERPAfT N0. Building Inspector: SEP 2 2025 I I , Applications and forms must be filled out in their entirety.incomplete appffcations will not be accepted. Where the 9 ppkant is not the owner,an I Building Department Owner's Authorization-form JPage 2)shall be compie'ted. Town of Southold I Date: i OWNERIS)OF PROPERTY: i ! fame: 6 r&c 5CTiV1# 1000- 05 pC, ,��1�5� � 004 oi Project Address ? LfS I/1 6t �op held Phone#: ) _ 3 t8 2 - -7 o Lf 9 3 Email: Co ao Mailing Address: i CON7ACT PERSON. Name: LSD r--rA,) Mailing Address: -7 410 S o w &q v? Phone#: Email: pf.l fys,4,5 f, as l DESIGN PROFESSIONAL INFORMATION. i I Name: � I Mailing Address: Phone#: CONTRACTOR INFORMATION: I Name: E�,i f-M Mai Address: Phone � � Si"d ) r,H�4�- +Vcy, #: aa,^, tEmail: j�i /'IJ\ .�� C�, 5 � -1 I e ' i DESCRIPTION OF PROPOSED CONSTRUCTION � ❑New Structure ❑Addition Iter Lion ❑Repair ❑Dem_olition C ., Est' ated Cost of Project: � ��� � Q cJc� i Will the lot be re-graded? ❑Yes,:gNo Will ex oe ss nil b¢ re From premise ? ❑Yes�,�0 lacercSALM C2-- 805Ch 3 -fin S .s lah. PROPERTY INFORMATION Existing use of property: i Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONO IF YES, PROVIDE A COPY. ck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authoraed inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted Bellpri name):Lorraine DiPenta ®Authorized Agent El Owner Signature of Applican,. � � Date: 711--21zS STATE OF NEW YORK) SS: COUNTY OF Suffolk Lorraine DiPenta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 7day of \�J C,,,- 20 z 5� Not r Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at a3 5 VR -> a Ue C �-Sl,L�/"h6p jr do hereby authorize �-/ -� j to apply on my be alf to the Town of Southold Building Department for approval as described herein. Owner's Sig ture Date LOUIS J ROMEO 7�q Notary Public,State of New York No.01 R06314813 Prin�Owner ��� Qualified in Suffolk County Commission Expires November 17,20 L 2 j� AREA SUMMARY SHED ADDITION & SEPTIC SYSTEM LOT AREA = ca.16,753 SF = 100 00% EXIST'G BLDG. COVERAGE = ca. 2,337 SF = 13.95% ADDED SHED COVERAGE = ca. 80 SF' = 0.48% TOTAL BLDG. COVERAGE = ca. 2,417 SF = 14,43% W y ADJACENT DWELLING W J U W • U N 15' S' BYRNE = 1 ESIDLI,IC ' o ;.. •- o� pROPER7Y(l = 23oT OYVID 45 B EW AVE PROPOSED D g' NE 201,80 SF 44 W o ARCHITECT FRANK UELLENDAHL- DRIVEWAY o P 0 BOX 316 rs GREENPORT, NY 11944 TEL 631-477 6624 W 75 0' S�BgC 35' FRONT YARD DECK DECK OWNERS VERONICA KALISKI w 50.5' ; Cd &THOMAS BYRNE 2345 BAYVIEW AVE 11971 E Q g ZONE AEo w ti EL. 10 /2-STORY a Q FRAME DWELLING �� N l zttz 0 W � a 1 ao ;. CD � " - ? w FINAL. MAP ; all N 1Co o REVIEWED BY ZBA o �� CC � o SEE DECISION # � (; z DATE. 08/17/2016 DATED Ill I • ol(D g m 3 SCALE 1/16• a 104.01, ECEIVED SITE PLAN �,FIV " U� AUG 2 DWG NAME OFAD FN ZONING BOARD OF APPEALS g� A-1 ,D ®a DWG NO I, CONTRACTOR TOM BYRNE d �' ® ENERGY SOLAR I BATTERY BACKUP 1631.779.79931 E2BYB.COM AHJ UTILITY SCOPE OF WORK VICINITY MAP ELEMENT ENERGY LLC TOWN OF SOUTHOLD PSEG LONG ISLAND (N) 14.875KW DC/11.200KW AC ROOF MOUNTED PV SYSTEM 7470 SOUND AVE, (35)JINKO SOLAR JKM425N-54HL4-B MODULES (425W) ______________ _____- MATTITUCK, NY 11952, USA (35) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS �a�` +1 631 760 7262 (01) ENPHASE IQ 5/5C COMBINER PANEL LIC TYPE: HOME- �'Qh� � IMPROVEMENT, MASTER CODES AND STANDARDS WITH AMENDMENTS ELECTRICIAN 2020 BCNYS 2020 FCNYS LIC NO.: 67461-HI, 52689-ME- �` � _ 2020 RCNYS 2017 NEC 2345;Bayview Ave, PROJECT INFO&ADDRESS Soutfiold,NY 11971,•- • United States• , TOM BYRNE i 2346 BAYVIEW AVE, ENVIRONMENTAL ! SOUTHOLD, WIND SPEED: 134 MPH NY 11971, USA SNOW LOAD: 25 PSF EXPOSURE CATEGORY: C --- — ---- ---- -- -- -- - SYSTEM SIZE DC SIZE: 14.875 KW DC-(STC) AC SIZE: 11.200 KW AC GENERAL NOTES It is a violation of the Law forE nyperson,unLess PROJECT NOTES: SHEET INDEX acting'vnderth6ditec'tion:of licensed -THIS PHOTOVOLTAIC PV SYSTEM SHALL COMPLY WITH THE professional,to.alteran item in'anyway.lean ( ) PV-1 COVER SHEET NATIONAL ELECTRIC CODERTICLE 690,ALL ETER NO: 98543720 itern.bearingtheseatofalfc :sed"professional (NEC)( ) PV-2 SITE PLAN-1 - MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, A CT NO: 9625500441 PV-2.1 SITE PLAN-2 aisff aixtotheiritemtheirBeata dthenotation ltered;.the altering ficens dprofessionatshall. AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY PV-3 ATTACHMENT PLAN "altered by"followe.d'by their signature and HAVING JURISDICTIONS (AHJ)APPLICABLE CODES. PV-3.1 STRUCTURAL PLAN the -THE UTILITY INTERCONNECTION APPLICATION MUST BE date of-such.alteration,'and ;specifi � PV-4 ELECTRICAL APPROVED AND PV SYSTEM INSPECTED PRIOR TO.PARALLEL PV-4.1 ELECTRICAL CALCULATIOII gcriptionof the.alteration _ OPERATION CO PV-5 LABELS ,� I -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-6 RESOURCE DOCUMENT " 0 DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN I ¢I< r PV-6.1 RESOURCE DOCUMENT c', ACCORDANCE WITH NEC 690.41 B -ALL PV SYSTEM COMPONENTS( MODULES, PV-6.2 RESOURCE DOCUMENT PV-6.3 RESOURCE DOCUMENT UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT ' Oar PV-6.4 RESOURCE DOCUMENT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR US IN PV-6.5 RESOURCE DOCUMENT PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: V PV-6.6 RESOURCE DOCUMENT 7=_ n:.� MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 PV-6.7 RESOURCE DOCUMENT CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, PV-6.8 RESOURCE DOCUMENT NVsMipq Consufting, PLLC 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 76 4. Meadowbrock Drive,Alpine U -MAX DC VOLTAGE CALCULATED USING MANUFACTURER New York CO.A#00Z2571 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX Signed 7/30/2025 DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. Expires 7/31/2027 -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED DRAWN BY MP AND LISTED FOR THE APPLICATION PER 690.4. SHALL BE DATE 7/30/2025 INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.31. REVISION -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL SIGNATURE BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS PV-1 REQUIRED BY THE NEC AND AHJ. COVER SHEET CONTRACTOR SCOPE OF WORK (N) 14.875KW DC/11.200KW AC ROOF MOUNTED PV SYSTEM ® ELEMENT (35)JINKO SOLAR JKM425N-54HL4-B MODULES j orENERGY U (01) ENPHASE IQ 5/5C COMBINER PANEL (35) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS SOLAR I BATTERY enc,cualea,.779.7993IEzsrs ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER .9� ELECTRICIAN LIC NO.: 67461-HI,52689-ME PROJECT INFO&ADDRESS TOM BYRNE 2345 BAYVIEW AVE, SOUTHOLD, NY 11971, USA SYSTEM SIZE J �Og DC SIZE: 14.875 KW DC-(STC) AC SIZE: 11.200 KW AC (E)MAIN HOUSE �� / ItisaViblation.of the lawforan f person,unless actingunderthb direction of.a tensed / professional,to atter;an item in any tinny If an 0� item beaTing the seaLof a ficen ed professional O / 'is altered;the altering licensed professional ghaft l� affix to their item their,seaL a nd the notation alteredbjf'followedbytheirsinatu nij ; e , / date of such alteration,and a sq fit ��rl•� description ofthe alteration. CC} _ � r jji SS4❑ 1 yS'aliog 00hrL ling, PLLC .76 N. Meadowblrook Drive,Alpine UT LEGEND �� / New York COA.#0022571 ®FIRE PATHWAYS Expined res res 7/31/2025 2027 PROPERTY LINE 0 FENCE DRAWN BY MP ® SKYLIGHT/CHIMNEY DATE 7/30/2025 O VENT/OBSTRUCTION REVISION SIGNATURE SITE PLAN-1 TOTAL ROOF SQUARE FOOTAGE IS:2,407.53 FT' PV-2 SCALE:1/32" = 11-011 NEW ARRAY SQUARE FOOTAGE IS: 735.67 FTz COVERED BY SOLAR IS: 30.56% SITE PLANA SCOPE,OF WORK CONTRACTOR (N) 14`.875KW DC/11. OKW ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:2,407.53 FTz (35)JINKO SOLAR JK 42 -54HL4-B MODULES NEW ARRAY SQUARE FOOTAGE IS: 735.67 FT2 h ® ENERGY E L E M E N T COVERED BY SOLAR IS: 30.56% I a(35) ENPHASE IQ8MC-7 -US (240V) MICROINVERTERS(01) ENPHASE IQ 5/5C MBINER PANEL �,9 SOLARI BATTERY BACKUPI631.779.7993IE25YS.COM y' �F jilt ENERGY LLC q 7470 SOUND AVE, + 631 760 7262 M1 I 11952, USA y (E) UTILITY METER LIC TYPE: HOME V C), (� (UNDERGROUND SERVICE) IMPROVEMENT, MASTER Gp LADDER ACCESS (STRUT MOUNT) unn ELECTRICIAN (N) CONDUIT RUN !r7 fib, LIC NO.: 67461-HI, 52689-ME (E)ATS PANEL ys '�15r (INSIDE BASEMENT) r;�b�,�S'�a O PROJECT INFO&ADDRESS / nj �j i TOM BYRNE cy (N) ENPHASE IQ 5/5C COMBINER PANEL O" 2345 BAYVIEW AVE, WITH ENPHASE IQ GATEWAY 3 SOUTHOLD, (OUTSIDE HOUSE) O NY 11971, USA (N)VISIBLE LOCKABLE LABELED AND FUSED AC DISCONNECT SYSTEM SIZE DC SIZE: 14.875 KW DC-(STC) (UTILITY DISCONNECT) Q (OUTSIDE HOUSE) 11 AC SIZE: 11.200 KW AC Cb It is a violetiori of the law for any person,unless (E) MAIN SERVICE PANEL acting,unddr the direction of a licensed (INSIDE BASEMENT) prolessiona 4 to atter an iten in any way.if an item bearing the seal of a[i ensed professional 'is altered,the altering.lice used professional shall affix to their item their seat the notation "attered by-followed by their signature and the 3� (N) (35)JINKCZ SOLAR JKM425N-54HL4-B MOlWJ1J:_§A cRAueration,and a specific A, ENPHASE IQ8 2-M-US (240V) MICROINV O cr P� 'UNDER EACH DULE (240V) e 'han of thealteratio ��(w t„ 4i y C� llef k IN C1) ' M WYsMin..g Consulting, PLLC 76 N. Meadowbroo:k Drive,Alpine 11 LEGEND New Park COA#0022571 ®FIRE PATHWAYS Signed 7/30/2025 PROPERTY LINE t��O Expires 7/31/2027 0 FENCE ® SKYLIGHT/CHIMNEY DRAWN BY MP 0 O ❑ VENT/OBSTRUCTION 3,X DATE 7/30/2025 REVISION SIGNATURE SITE PLAN-2 rb SCALE:1/8"=V-0" PV-2.1 SITE PLAN-2 0 000 . A 0 ED AS NOTED.7 COMPLY WITH ALL CODES OF DATE-. B.P.# <S S YORK STATE&TOWN CODES A FEE �� BY: REQUIRED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT 60 OLD TOWN ZBA 631-765-1802 8AM TO 4PM FOR THE OLD TOWN PLANNING BOARD FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED 9SXCHO MOLD TOWN TRUSTEES FOR POURED CONCRETE N.Y.&DEC 2. ROUGH- FRAMING&PLUMBINGSDUTHOLDHPC 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. All CONSTRUCTION SHALL MEET THE ' REQUIREMENTS OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS Bosch dCapacity .4 0A OCCUPANCY OR BOSCH �= USE IS UNLAWFUL KITH®UT CERTIFICATE OF OCCUPANCY Product Specifications ELECTRICAL INSPECTION REQUIRED A NO CERTIFIED- 'l CERTIFIED-'! C offi U Intertek Table of Contents 1 Product features 4 2 Nomenclature 5 3 Product specifications 6 4 Dimensions 7 5 Blower Data 8 6 Heater Kit Data 9 Bosch Thermotechnology Corp. 06.2016 Data subject to change :a � as � v• a' e I Product features ► Multi-speed ECM blower motor. ► Factory-installed TXV metering. ► Multi-position Installation-upflow or horizontal right standard; field convertible to horizontal left or downflow. ► Multiple electrical entry locations. ► Field-installed electric heater kits 5,7.5,10,15,20KW available as an accessory. ► Dual front panel design for ease of maintenance. ► Blower and coil easy slide out for ease of maintenance. ► Fully-insulated cabinet design. ► Horizontal and vertical condensate drain pans standard. ► Condensate drain pan is polymer with UVC inhibitor. ► Primary and secondary condensate drain fittings. ► Factory-sealed cabinet certified to achieve 2%or less air leakage rate at 1.0 inch water column. ► Integrated filter rack with tool-less door access. ► AHRI and ETL Listed. Data subject to change 06.2016 Bosch Thermotechnology Corp. era o• i ar,97 . a 2 Nomenclature B V A-24 W N1 — M 18 Efficiency 18: 18 SEER Power Supply M: 208/230V 1 Ph, 60Hz Refrigerant N1: R410A Function Type W: Wired Controller Nominal Capacity 24: 24X 1,000BTU/H [2 nominal tons refrigeration] Series A:A Series Unit Type V: Vertical Air Handler Bosch Figure 1 Bosch Thermotechnology Corp.106.2016 Data subject to change 1 1 3 Product specifications Cooling capacity Nominal Cooling(BTU/h) 24,000 34,600 47,000 57,000 Nominal Heating(BTU/h) 24,000 33,600 46,500 55,000 Blower Diameter 10%11 Width 8" 10%11 10%11 10%11 Fan Motor Horsepower(HP) 1/3 1/2 3/4 3/4 Full Load Amps 2.8 4.1 6.0 6.0 Refrigeration System Refrigerant Line Size' Liquid Line Size("O.D.) W, '/a° '/e' W, Suction Line Size("O.D.) '/4" '/4" %" 7 9" Refrigerant Connection Size Liquid Line Size("O.D.) W, W, %11 '/e" Suction Line Size("O.D.) 3/4" 3/4" 78'' Expansion Device[TXV=Thermal Expansion Valve] TXV TXV TXV TXV Decibels dB(A) HioSpeed 62 65 67 68 MediumSpeed 59 62 63 64 LowSpeed 55 58 59 60 Electrical Data Voltage-Phase-Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Minimum Circuit Ampacity2 3.5 5.1 7.5 7.5 Max.Overcurrent Protection 3 15 15 15 15 Min/Max Volts 187/253 187/253 187/253 187/253 Air Filter Air Filter Sizes 18"x 20" 18"x 20" 20"x 22" 20"x 22" Weight Equipment Weight(Ibs) 119 126 162 170 Ship Weight(Ibs)4 132 139 180 188 Table 1 1 Tested and rated in accordance with AHRI Standard 210/240. 2 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. 3 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. 4 Weight shown includes packaging Data subject to change 06.2016 1 Bosch Thermotechnology Corp. ' Doi 'p Y. D �a,t•D 4 Dimensions • I NOTE:25"CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLYAIR FLANGES ARE PROVIDED HIGH VOLTAGE CONNECTION FOR FIELD INSTALLATION 1-'/6",%6"DIA KNOCK OUTS W D A 5 7/8"(149) 0.75"(19) 3 7/8"(99) 10.32"(262) 7/8' 22) 1 7/8"(49) 3/4"<19) CIRCUIT BREAKER SWITCH (ELECTRIC HEATER ONLY) SUCTION LINE COPPER CONNECTION LIQUID LINE COPPER CONNECTION H 3.0"(75.5 tic F 3.0"(75.5)E 1.7"(43.5) 3,85"(98) 1.4"(35.5) 2 (66) 1.65" B 2,28" (42) (57.9) 0.67"(17) C INLET INLET (FRONT VIEW) (RIGHT SIDE VIEW) AUXILIARY DRAIN CONNECTION 3/4" FEMALE PIPE THREAD(NPT) PRIMARY DRAIN CONNCETION 3/4" FEMALE PIPE THREAD(NPT) Figure 2 a ® D aa- - 24 46'h"[1180] 19%-[500]' 21%"[550] 18"[456] 165/,fi'[416] 205/,s'[516] 133/<"[350] 155/""[390] 36 46'/2"[1180] 19%"[500] 21%"[550] 18"[456] 165/,5"[416] 205/,s"[516] 133/a"[350] 155/,6"[390] 48 54%"[1385] 22"[560] 24"[610] 19Ya"[496] 183/V[476] 223/i'[576] 195/,6"[492] 21"[532]' 60 54'/?[1385] 22"[560] 24"[610] 19Y2"[496] 18%"[476] 223/,"[576] 195/,fi'[492] 21"[532] Table 11 Bosch Thermotechnology Corp.106.2016 Data subject to change $ 3r�1>. ��••3. � y r4 s�k�� 0 1 1 i"N Y d l•'" ll _ew 5 Blower Data Airflow performance Airflow performance data is based on cooling performance with a coil and no filter in place.Check the performance table for appropriate unit size selection.External static pressure should stay within the minimum and maximum limits shown in the table below in order to ensure proper operation of both cooling, heating,and electric heating operation. 1 9 1 mm m 1 / 1 1 870 / � 9 / li+ 1 8 1 1 SCFM 1016 955 914 827 790 741 691 657 Tap(5) Watts 139 146 157 165 174 185 195 202 209 SCFM 955 892 853 804 768 729 671 630 --- Tap(4) Watts 118 125 135 142 152 162 169 178 --- Tap(3) SCFM 927 829 789 739 701 643 597 — 24 -Default Setting Watts 109 105 113 121 131 137 1 147 Tap(2) — SCFM 887 766 671 631 567 522 465 — Watts 97 87 83 93 99 108 112 -- --- SCFM 829 698 547 366 347 277 234 Tap(1) Watts 81 71 60 54 60 64 72 — SCFM 1452 1403 1343 1287 1214 1144 1085 1022 968 Tap(5) Watts 253 264 271 284 296 303 313 324 329 Tap(4) SCFM 1255 1203 1150 1062 995 920 854 797 719 -Default Setting Watts 170 182 193 201 212 221 229 239 244 SCFM 1109 1050 985 897 841 841 766 702 617 36 Tap(3) Watts 126 136 147 154 164 170 180 187 195 SCFM 1020 907 818 733 673 586 520 — Tap(2) Watts 103 98 109 114 124 129 139 — SCFM 962 807 627 551 450 380 296 --- Tap(1) Watts 90 80 71 79 83 93 96 — SCFM 2072 2013 1935 1923 1878 1830 1783 1736 1688 Tap(5) Watts 447 464 489 497, 514 530 1 545 558 570 SCFM 1860 1816 1735 1670 1640 1591 1542 1504 1481 Tap(4) Watts 348 364 383 395 408 418 429 451 463 Tap(3) SCFM 1702 1651 . 1560 1547 1497 1438 1385 1331 1280 48 -Default Setting Watts 268 281 304 312 325 337 349 361 375 SCFM 1393 1358 1179 1155 1139 1074 1020 964 896 Tap(2) Watts 227 234 258 269 270 283 296 313 325 SCFM 1365 1239 1078 1050 965 904 886 831 797 Tap(1) Watts 220 226 243 264 269 281 293 301 317 SCFM 2054 2015 1947 1928 1886 1846 1804 1742 1654 Tap(5) Watts 470 495 518 528 542 553 569 567 548 Tap(4) SCFM 1883 1840 1783 1754 1712 1670 1622 1579 1541 -Default Setting Watts 367 388 411 420 422 445 454 466 479 _17- SCFM 1721 1674 1582 1566 1528 1484 1443 1401 1345 60 Tap(3) Watts 289 305 327 330' 341 1 353 365 378 387 SCFM 1515 1463 1386 1358 1308 1262 1215 1153 1073 Tap(2) Watts 205 218 235 239 251 263 276 285 301 SCFM 1337 1265 1156 1148 1095 984 955 963 789 Tap(1) Watts 145 157 173 178 186 197 212 225 235 Table 3 0 -Bold outlined areas represent airflow outside of the required 300-450 cfm/tan range. Airflow based upon Air Handler Unit operating at 230V with no electric heater kit and no filter.Airflow at 208V is approximately the same as TSCFM means Standard Cubic Foot per Minute. 230V. Data subject to change 06.2016 1 Bosch Thermotechnology Corp. 6 Heater Kit Data m M!Zi {^ sb� � om AA- .g MM WEHK05A 5 28.5 24.9 30 25 • • • • • WEHK08A 24 7.5 41.5 36.3 45 40 X X • • • WEHK10A 10 54.5 47.6 60 50 X X • • • WEHK05A 5 29.7 26.2 30 30 • • • • • WEHK08A 7.5 42.7 37.5 45 40 X • • • • WEHK10A 36 10 55.8 48.8 60 50 X X • • • 55.8+26.1 48.8+22.6 60+30 50+25 WEHKI5B 15 X X • • • 81.8 75.3' 90` 80' WEHK05A 5 33.6 301 35 35 • • • • • WEHK08A 7.5 46.6 41.4 50 45 • • • • • WEHKIOA 10 59.6 52.7 60 60 X • • • • 48 59.6+26.1 52.7+22.6 60+30 60+25 WEHKI5B 15 X X • • • 85.7' 75:3' 90` 80' 59.6+52.1 52.7+45.2 60+60 60+50 WEHK20B 20 X X X • • 111.7' 97.8` 125' 100' WEHK05A 5 33.6 30.1 35 35 X X • • • WEHK08A 7.5 46.6 41.4 50 45 X X • • • WEHKSOA 10 59.6 52.7 60 60 X X • • • 60 59.6+26.1 52.7+22.6 60+30 60+25 WEHKI5B 15 X X • • • 85.7` 75.3' 90` 80` 59.6+52.1 52.7+45.2 60+60 60+50 WEHK20B 20 X X X • • 111.7' 97.8' 125` 100` Table 4 •-means available X-means not available ' means single circuit 1 Electric Heater kit suitable for AHU multi position installation. WEHK05A 5kW Heat Kit,Double Pale Breaker • • • WEHK08A 7.5kW Heat Kit,Double Pole Breaker • • • • WEHKIOA 10kW Heat Kit,Double Pole Breaker • • • • WEHKI5B 15kW Heat Kit,Double Pole Breaker X • • WEHK20B 20kW Heat Kit,Double Pole Breaker X X • • Table 11 •-means available X-meansnotavailable Bosch Thermotechnology Corp. 06.2016 Data subject to change United States and Canada Bosch Thermotechnology Corp. 50 Wentworth Avenue Londonderry,NH 03053 Tel:866-305-9974 BTC 761701104 B /06.2016