Loading...
HomeMy WebLinkAbout50490-Z �o�suf TOWN OF SOUTHOLD a cGy�i BUILDING DEPARTMENT TOWN CLERK'S OFFICE y x SOUTHOLD, NY �4 t� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50490 Date: 3/29/2024 Permission is hereby granted to: 3 Peconic River LLC 90 Lafayette Ave Sea Cliff, NY 11579 To: demolish the existing dwelling and accessory garage as applied for per DEC Non-Jurisdiction letter and Trustees approvals. At premises located at: 450 Basin Rd, Southold SCTM # 473889 Sec/Block/Lot# 81.-1-18.1 Pursuant to application dated 2/8/2024 and approved by the Building Inspector. To expire on 9/28/2025. Fees: DEMOLITION $1,15 5.40 Total: $1,155.40 Building Inspector' Evan T.Steffens N a ti o n a Igrid Senior Supervisor Gas Customer Connections,NY January 31, 2024 Adam Prestandrea 450 Basin Road Southold,NY 11971 E-Mail: APRESTANDREArai.GMAIL.COM ; KIMBERLY@VITALHABITATS.COM National Grid WO#: T102597390 Service Address: 450 Basin Road Southold,NY 11971 To Whom it may concern, This Letter is to advise you that National Grid investigated your request and confirmed that the subject property does not have an active gas service line. By Law, excavators and contractors working in New York City and Nassau and Suffolk Counties must contact New York"811"at least 2 full business days, not including the day of contact, prior to digging by calling"811"or by using the website htttss://newvork- 811.com/. This confirmation letter of no active gas service line to the subject property does not relieve the excavator of contacting NY"811". If you have any further questions, kindly contact me at 833-359-0645. Respectfully, Evan T. Steffens Senior Supervisor Gas Customer Connections NY 16501slip Ave,Brentwood NY 11717 T;833-359-0645 evansteff_ensirLnationalS is d.com p&dl rnd r cessina,:i&gational rid:com, FPSH.../[l, .c � ��.3 2/2/2024 PECONIC RIVER LLC Service To: 90 LAFAYETTE AV, 450 BASIN RD SEA CLIFF,NY,NY 11579 SOUTHOLD,NY 11971 Customer Project#:900000189875 Dear PECONIC RIVER LLC: This is to advise you that the PSEG-LI electric facilities at the above referenced location have been disconnected and removed off the building structure that is located on the property. Please note that there may still be PSEG LI facilities located within the property boundaries and that NYS law(NYCRR Part 753)requires all contractors to call for a utility locate (NY 811)prior to performing any ground excavation or regrade activity. The call to the 811 Call Center must be done at least 2 business days prior to the start of the work and confirmation of utility marks having been identified must be received from all the facility owners prior to any site work. You must also contact National Grid at 631-348-6150 to procure a letter of demolition associated with natural gas service,whether or not your home or business uses natural gas. If you have any questions regarding the above,please contact Building&Renovation Services at 1-844-341-6378 or via email at BRSLI@PSEG.com. Very truly yours, Katherine Gianelli Building&Renovation Services PSEG-LI ELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) --- -77-1--- ---------------------------------- cl) FOUNDATION (2ND) • O cn ROUGH FRAMING & —------- PLUMBING 00 INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Td-p- "K4 o M.m Co CA o ro NEAN YOPK S"'ATC- DE-PART IEN`8' or r N ViROl` Mr-.N't«At. t>UNY Q Stony Brook,50 Qrcl�z Road,Stony 8roalf.NY 11790 P:(Qzl)444-On5!Fi(6,31)444-OJBO www.d@cm) pov LETTER OF NO JURISDICTION April 6, 2021 Peconic River LLC c/o Adam Prestandrea 90 Lafayette Ave Sea Cliff, NY 11579 Re: Application # 1-4738-01007/00005 Peconic River LLC Property, 450 Basin Dr, Southold, NY SCTM # 1000— 81 — 1 — 18.1 Dear Adam Prestandrea: Based on the information you submitted the Department of Environmental Conservation has determined that the existing bulkhead shown on the survey by Kenneth M. Woychuk, dated December 11, 2019, is functional, more than 100 feet in length and was constructed before August 20, 1977, as shown on Tidal Wetlands Map# 718-546 and AeroGraphics Exposure#73-2048. Therefore, the property landward of the bulkhead is beyond Tidal Wetlands Act (Article 25)jurisdiction and no permit is required for work landward of this structure. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or disturbance within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the jurisdictional boundary and your project (i.e. a 15' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. This letter shall remain valid unless site conditions change. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sinc ely, herri Aicher Deputy Regional Permit Administrator cc: En-Consultants BN1HP File i` €3tt�rYgts� �c�i�ry►�,n�urot s�f till'"' G41ytlUi:plcltNjgl ,'�� ilrl^.lnlllllllr "�!> ��naHtvukinn Glenn Goldsmith,President � 1,f SO Town Hall Annex 54375 Route 25 A.Nicholas Krupski,Vice President P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly Telephone(631) 765-1892 Elizabeth Peeples �� Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD April 20, 2023 Robert Herrmann En-Consultants 1319 North Sea Road Southampton, NY 11968 RE: PECONIC RIVER, LLC 450 BASIN ROAD, SOUTHOLD SCTM# 1000-81-1-18.1 Dear Mr. Herrmann: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, April 19, 2023: RESOLVED that the Southold Town Board of Trustees grants a One (1) Year Extension to Wetland Permit#9930, as issued on June 16, 2021. This is not an approval from any other agency. If you have any questions, please do not hesitate to contact this office. sincerely r Glenn Goldsmith President, Board of Trustees GG:dd Glenn Goldsmith,President j �� ►�Q(f Town Hall Annex 1f �d A.Nicholas Krupski,Vice President 54375 Route 25 �"A4 �? �' P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly Elizabeth Peeples Telephone 65-1892 Fax(631)1)76 766-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD January 18, 2024 Robert Herrmann En-Consultants 1319 North Sea Road Southampton, NY 11968 RE: PECONIC RIVER, LLC 450 BASIN ROAD, SOUTHOLD SCTM#1000-81-1-18.1 Dear Mr. Herrmann: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, January 17, 2024: WHEREAS, En Consultants, on behalf of PECONIC RIVER, LLC applied to the Southold Town Trustees for an Amendment to Wetland Permit#9930 under the provisions of Chapter 275 of the Southold Town Code, the Wetland Ordinance of the Town of Southold, application dated December 26, 2023, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council and to the Local Waterfront Revitalization Program Coordinator for their findings and recommendations, and, --- WHEREAS;the-LWRP-Coordinatorissued-a-re-commendation th-at`tht praposed'actioTFb—"'_-""-'---- found Consistent with the Local Waterfront Revitalization Program policy standards, and, WHEREAS, the LWRP Coordinator recommended that the detached deck be found Inconsistent with the LWRP, and, WHEREAS, the Board of Trustees has furthered Policy of the Local Waterfront Revitalization Program to the greatest extent possible through the imposition of the following Best Management Practice requirements: deck location will no longer be seaward of flood zone, and WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on January 17, 2024, at which time all interested persons were given an opportunity to be heard, and, ,.2 WHEREAS, the Board members have personally viewed and are familiar with the premises in question and the surrounding area, and, WHEREAS, the Board has considered all the testimony and documentation submitted concerning this application, and, WHEREAS, the structure complies with the standards set forth in Chapter 275 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT, RESOLVED, that for the mitigating factors and based upon the Best Management Practice requirement imposed above, the Board of Trustees deems the action to be Consistent with the Local Waterfront Revitalization Program pursuant to Chapter 268-5 of the Southold Town Code, and, BE IT FURTHER RESOLVED, that the Board of Trustees APPROVE the Amendment to Wetland Permit#9930 for a revised site design that results in a reduction in the combined structural footprint of the proposed dwelling, deck and pool, specifically to demolish existing two-story, 2,300 sf, FEMA- noncompliant, single-family dwelling with 460 sf attached deck and 761 sf detached garage, and construct new 1 and 2-story, 2,576 sf, FEMA-compliant, single-family dwelling with a 2.3' x 29.1' easterly roof overhang, 6.1' x 17'4 and 15.5' x 20' covered porches and steps, 4.9'x 10.6' and 5' x 12.8' areaways, 17' x 40' swimming pool (equipped with saltwater filtration system), 1,293 sf attached deck with steps and, on top of deck, 5.8'x 6.5' enclosed seasonal bathroom, 4' x 5.5' outdoor shower, and 6.5' x 10.8' trellis over outdoor bbq; remove existing nonconforming septic system located +42' from bulkhead, and install new I/A OWTS sanitary system more than 100 feet from bulkhead; install a drainage system of drywells to collect and recharge roof runoff and pool backwash; install new pervious gravel driveway and parking areas; install 4' high pool enclosure fencing, pool equipment/heat pumps, generator, and 500 gal underground propane tank; remove specified trees located no closer than +69 feet from bulkhead; and establish 27' to 39' wide, approximately 5,959 sf vegetated buffer area adjacent to bulkhead, consisting of approximately 4,259 sf embankment and approximately 1,700 sf area up to 10 feet landward of top of bank and retaining wall; and as depicted on the site plan prepared by DiLandro Andrews Engineering, last dated December 14, 2023, and stamped approved on January 17, 2024. Inspections are required at a fee of$bU.UU per inspection. (See attached schedule,) Fees: None Very truly yours, i l Glenn Goldsmith President, Board of Trustees GG/dd GENERALNOTES: 1. THE DESIGN ENGINEER SHALL OBSERVE THE OV✓TS PRIOR TO BACKFILLAND DURING ��, BY STEM STARTUP. ffr DILBDd,o 2. THE OWTS INSTALLER SHALL HOLD APPROPRIATE ENDORSEMENTS FROM SUFFOLK1.:�_ COUNTY DEPARTMENT OF HEALTH AND SHALL BEAN AUTHORIZEDINSTALLER. ♦ _I AOd�OWS 3. THE OWTS INSTALLER SHALL REGISTER THE ONSITE TREATMENT SYSTEM WITH SUFFOLK 4 SOUTHOLD BAY IM COUNTY DEPARTMENT OF HEALTH.THE ENGINEER OF RECORD SHALL PROVIDE RECORD DOCUMENTS AS REQUIRED BY SCDH. Ise Cpwnty pd.39 4. AN EXECUTED OPERATION AND MAINTENANCE CONTRACT BETWEEN THE MAINTENANCE suite to PROVIDER AND THE PROPERTY OWNER SHALL BE PROVIDEDTO'THE SCDH. EXISTING 9eaUumptarN N.Y.tt06a 5. A GARBAGE GRINDER SHALL NOT BE INSTALLED UPSTREAMOF THE DINTS. SEPTICTBR fi. OWTS SHALL BE TESTED FOR WATER TIGHTNESS PRIOR TO ARRIVAL TO THE SITE USING Omcehs.ls3t1)4&095a METHODAPPROVEDBY THENANUFACTURER. 7. ALL ELECTRICAL LINES FROM THE DWELLING TO THE CONTROL PANELAND FROM THE b X yaJ• 3 1E F ypo`,p.or o0q CONTROL PANEL TO THE JUNCTION BOX SHALL BE SEALED AND WATER TIGHT.. ° C B. CONTROL PANEL TO SE SET ON A PRECAST CONCREFE PEDESTAL AND SET 21NCHES8657'�0•E v�6'1Ai v°b°YNn eui�4LEowc w ^ax o ABOVE GRADE TO PREVENT WATER INTRUSION. -. \•P. 46.97 s Riq' - PROPOSEDJ2TT0>:34WIDE59595F '1°m awr.'y yy. E 9. OWTS BHA LOCATED MINIMUM 3'-0•FROM THEDRIVEWAY:A6INCH HIGHPRECAST BUFFER AREA INCLUDING EXISTING SW15'BI'vSo -'... . •.�.I�° CURB SHALL BE INSTALLEOIN-BETWEEN THE THE DRIVEWAY AND THE OWTSJF3FEET 4,259SF NAYURALLYVEGETATED 02J' t°u •' M0•s °v AjeWJ%i OEM RFavai'ealt'........ .... aat Y BE CANNOT BE MAINTAINED. BANKAND IO'WIDE 1700 BF 'or trewE WKatY4ltlmµml.... .. ........•,.,•,,.,•,•,., Y•c^SOPf Aw NDN-TURF OUFFEATO BE 60.'.'.'.'.' '.'.'.'.'.'..'OxS'WLW6c'Oauir 10. NEW VAOWT BYSTEM TO BE VENTED THROUGH PLUMBING, ESTABLISHED IN PLACE OF EXIBTING asu .. ........ ... ...... ... NO HOUSE TRAP TO BE INSTALLED .. LAWN IAWIMSER0FTOALL Mxn BANNRIMBERRET.WADY t� NawlalVltM°"y.B 3a2 PRWECT UMITING PENCE PARCEL INFORMATION: - PROPOSED d ¢ MD\OF OISTURBANCE49.4505F. DESCRIBED PROPERTT-014 DRYWELL FOR _ t' MAP OF PARADISE POINT SEC.1 POOL RACMASH FILED APR.I ITH,1963 NO.3761 - w•."�Iu'wu 00 SITUATEDAT:BAYVIEW PROPOSED4' _ ^ --- _;Tr - Ilrr TOWN OF SOUTHOLD POOL FENCE `r?mr''. a SUFFOLK COUNTY,NEW YORK G -ry_ -' g` ,- J r S.C.T.M.v f000'1.1.17518 -' ZIr'cnr o g sEaRu° EXISRNG GARAGE r AREA 32,WS S.F.OR 0.75 ACRES TO BE REMOVED _- r I ZONING DISTRICT:R-80 eXxo x/F or ' .,, _.- d• }O 1S(53izw_mm_ en ALLOWABLE LOT COVERAGE: 6,533 SF(20%OF LOT AREA) _Cfiau= °Yf vET¢2q E%ISrwG W O 2si0AYOWEILxG > Z O EXISTING HOUSE: 2.30a SF.t .�..�' ,s `, p :v'•',`+• 2J GARAGE: 761 SFf _ CT+ RO EO POOL °PROPoS G LK Q 1 Q 7t TEST %'p�rr,iwrcxuro° EIFV.° EXISTING < -O p N DECK: 460 SF3 —-' HOLE - ]a' _ , v.� ,. OBWR UNG ppEtep� Z = EXISTING TOTAL LOT COVERAGE:3,521 SFS=1a.8•/. O pROdSSE "-' A � e/�<u1w Q ED�F' PROPOSED CONROL 2 C"'° �COVEREO PRO OS>�OECK�a - - '® PROPOSEDENCLOSED 1S0 U O Q HOUSE: 2,5T65F. PANEL PORCH _ _ 4'X5.5'OUTGOOR W LE)Q •+ _ SH 5.6 OUTDOOR TO d 0 .1014 I PROPOSED ORYWELL DECK: 1,293 SF. '-• v UNO N/� COVERED PORCHES 416 SF. EXISTING " P? RY SINGE p 1STCRY.Bw 2STCRY�. �BTORY SMGLE 4;rDRr DWELLMo }._ SWIMMING POOL: 6125F. � 2 .'•mil - LY PESIOENCE iarTJ I ' NEWTOTALLOTCOVERAGE: 4,B97 5FA-IS.0% �•/- PF..ELEV.i 20 0 - TOTAL AREA OF DISTURBANCE:22.4505F. INTE PROPOSED U. (y';1 PROPOSED ENCLOSED PROPOSEDUIG P T SEASONAL BATHROOM • ELECTRIC LIKE '+�'e Z HYDROACTION ,q �W "O •'ti A14-BW SITE PLAN BASED ON SURVEY PREPARED BY: 2P PRRYOWPOSEEDF G3 Or)1,W KENNETH M WOYCHUK LAND SURVEYING,PLLC DISTRIBUTIONBOX p� ; p6O !v PROFESSIONAL ALDN SURVEYING AND DESIGN - - f°\\ ` L` I oRRyI IL i .=1 Q 0(n P. EX O.BOX 153 AQUEBOGUE,NEW YORK 11931 FUTURE UTURN °• • ;- MXMG PHONE(631)298-1588 I'M(631)298.1588 _ O PROPOSED WATER LINE Q Z O Q SURVEYED DEC.11,2019 I $`�q zg73" - \ n. (L p OO Q H x d I �`-��..`. ='-p '16 '15� pi 10-P0i6&gEEP W Q SANITARY SYSTEM INFORMATION: I �. t5 CHINO POOLS E/J �Z TOTAL NUMBER OF BEOROOM5:7 `Y ``=_v-LL +� 1i—� I' ,� 1-Q 0= VA SIZE REQUIRED:770GPD UTILNIESTO `-_ 13- ` BE REMOVED - 12 -rit_ \ EXISTING O Q LEACHING PROPOSED SO IRED:4TSFTa I / OAHVEWAY TBR w Q(]r Q PROPOSED SEPTIC BYSTEM: /x - LLJ (1) HYDRO ACTION AN-B00(WO GPD PROPOSED) I / 7 '�p�� -IO-.- �`].jd.q p� J7gY Q=v J (2) 10'_0.0X0'-0•DEEP LEACHING POOL(545 SF PROPOSED) r`_ yu.o •""•w�"2 ,A1 CC]xr �_,.\ r -�` O (1) 20•DISTRIBUTION BOX % xm ��{L 2.1 7N �f Of n4 � RMabn, NOTE: 4__ �A � 0e°alml°n -EXISTING SEPTIC TO BE REMOVED. I Nf N i wDATED SITE I 41hq 2 v EUI.TE' _TESTHOLEDATAY15Np1]FEMA NAPy361D3CO167Hs 1v14M02] St.17.9 O.D' YiPw9DL�TER APMOVED 6Y _ -BROWN SANDY LOW 1S0• `� BOARD OF I�RUSTEES 0.%ROWN LOAMY SAND B TOWN OF SOUTHOLD 0ia s, JD GRAVEL(SM) CONTOUR LEGEND: C64q°4B, PC 2 BBROWN MEDIUM SANG 1 DATE 7M12AR.�1711.D2/'- ANDGRAVEL(SP) —————— EXISTING CGNi0UR5 PROPOSED SEPTIC PLAN y/y' 4— GRAVEL p6CPOGEO CarvioU6s �.._ DaI°: NOTED3119r20 SCALE:II"U SUIe:NOTED GRAVEL(SP) ELEVATON46MNYN uaE eAsm Avw GS MTtM MAw 1FaJ1 EL:1.6' - 15.4' TREE LEGEND: -WATER SAND 8 GRAVEL(SP) y,�// OEC 262�1-IVI C-1 I EMB M EXI6TINO TPEE6 ------1 COMMENTS:GROUNDWATER ENCOUNTERED �J f sE REMo AT 15.4OBELOWB;GRADE Cyy �TC -= TEST HOLE BY: N.WOVCHUN LB uee1p Glenn Goldsmith,President oF S®(/�� Town Hall Annex 54375 Route 25 A.Nicholas Krupski,Vice President ® P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly G Telephone(631) 765-1892 Elizabeth Peeples �` ® �� Fax(631) 765-6641 ®�-100 BOARD OF TOWN TRUSTEES April 20, 2023 TOWN OF SOUTHOLD Robert E. Herrmann En-Consultants 1319 North Sea Road Southampton, NY 11968 RE: PECONIC RIVER, LLC 450 BASIN ROAD, SOUTHOLD SCTM#: 1000-81-1-18.1 Dear Mr. Herrmann: The following action was taken by the Southold Town Board of Trustees at their. Regular Meeting held on Wednesday, April 19, 2023. RESOLVED that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#9930 for the installation of a half-bathroom in the 5.3'x17.4' enclosed pool equipment structure, with attached 8.1'x17.4' pergola, located atop the 1,402sq.ft. attached pool deck; and for a 11.4'x26' pergola located atop the 669sq.ft. attached north deck; and as depicted on the site plan prepared by Grant Card, R.A., last dated March 15, 2023, and stamped approved on April 19, 2023. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not an approval from any other agency. If you have any questions, please do not hesitate to contact this office. Sincerely, Glenn Goldsmith President, Board of Trustees GG/dd BUILDING INFORMATION: S '� SOUIHOLD BAV APPROVE o,,,DOY Private �Ay' w gp BOARD OF O UTHOL Atldress: 4508aslnReed S N88'ST30'E46.9T S � � TOWN OFSOUTHOLD Residence Southold.NY 11971 A, z\y1 .. •y' tl D ATETIa Map ID: 1000-8I-1.18.1 �_ - -- S 82'4T56 Egg 450 Basin Road Zanin OStht R-80 S.0 d,NY I19T1 9 S88'15W'W Lot Area: 32.665 S/.(0.751ves) 8.2]' Lot Coverage Wculagons: �&fPj WRcwreer. AOawabie Lot Coverage 6,533s1(20%DI Let Area) ro Asvaw a,®°Sir"0" emru..x4wonvwcvmwD - '' .�uvwwvuaxv[snWxumw :. I .xe mwmccrmvwP,w .. Txd g . R wrxuxoazmuuwmvnAv EXISTING: muvnuwuwPuuamwDm ... - .: .�rr.y, 1jw .. ;I '(F.P.27 i.e slrzet�an Main Nouse: 2.]W sl.x xmmu.urwsuvn v.0 P Gare9a Dens: a60 s1 S e'• :•� .: n / __._.... s..m uwwa,..,.s Eaisllog Total Let CDv qw 3,521&f. 10.8%PROPOSED: % I - 6y M N Hausa' 2,350 SI mJ_ _ y, q A mucxurtu ee Pool Deck: 1p02 s1. NOW Deck(BB0) 6 s1. 2 or dry PN: M 33 sL MI ,O uoa ruRF Svdmrnmg Pool: 681.1. Nave Total Lot Coverage: 5,1]5 s1=15.1Y. Moveable GFA N/A COOVC '"Npo° Q •I `v Pca(.•Y um .,... ,aunt _ j _ I ♦♦♦♦�aPEo 4n rr. Proposed Bu0tlin9 GFA: `♦GY 15I Floor. 2.350s1. - 2nd Flaw test. Total Building GFA 3,606 el. '- _._ - - - BOUNDARY I 7 X F. r m,..umm X -sw+rtunmlEuwPDRunrwR,see PaDPoseD SEPTIC DI-.Puxev 7 , en �urEa— DEANDRDumReWSF 1SERWO FDRWWRIDNWLDe"e. EL00(1 _ON % .m %___•DW 'c `(Wren,_ e _ _______.m♦ ONE 1�(EL 2i) __________________ "•P01ptli_____________� A c--- PodF.�Ircuol as,rs wweAssO ox amarPAPnu+Evae _ _____.wqr-_ ____ __ __ __ _________ ZONE Y wmPeSswNWL s„RrereDWPrm,s. _ D sMaxsRrsrsreumranuWrlD oa _ _ —wD I y L (commove m rtI"i£'- - Eife E. ssf'L.xocc ry � , euacic Tara NuusPxoP eEonoous:m iE�wSwRo -," '� ' o !•/•,�///,/ /' '// ..'-PRDWSEDvuxwwY ♦♦♦I ``I 1 erP fwummlmv.:nw -� _" - - � -- E�; I: ` - �� � �//:''j�;'•,'l'/�%1 r,lj I,amn ♦y '♦.,_,� ;`i—Mt°�,m`""a.we. IA t DW f • ; I .n I. ed P.Nd+ V,w*,.M'meD.nm.omw•v wnDr � I I Hwy P m,E„P,a ;Iry I � w Fr.eim i DW3\♦ _ __ _ - _ _ __ oa •v ; r x� i •mowreovRs+'� - _. - \\ x m.pbmnaAuw % ,IN.,um .♦2 rOu.w s x rO ee Re.wED e`C 1 A��� jl z . TEST HOLE DATA ��. i2dE`-- .\ %\ /I 3°� �I Redesign WM2022 EL Off < OA' � o �� ♦ _ \\ / t ` Add pool baN b O].15302] -BROYM SANDY LOAM(ML) w, - _� \ o-,2....v\ / ! a' Pool EQWpoeN DA'BROWN LOAMY SAND6 �,,` \ Esm� --- \ REVISIONS: GRAVEL(SM) 2%BR0V/N MEDIUM SAND,. roEtEc \ `WDELK--/�VOF O 0 vw�cn.vl DATE:March 15.2023 AND GRAVEL(SP) 1 G1' -- ` µ tFR IE+ewpRtGn -MEOIUM SAND AND E f�\ wWiEB EB e—wWTRP� _ I / SCALE AS NDied GRAVEL BP) \ ` Eilip eRamm ..I . L1.6' 15A' rho DRAWING TITLE: gp Proposed Se.Ran -WATER SAND6GRAVEL(SP) � s r � ?�♦+ 17.0' 178pB,•� O DRAWWGNUMBER: ROgO y DOMA-BEL GROX.NDWGRAD WATER ENCOUNTERED 3782 0 I/pI AT 15.d'BELOW GRADE We.n.•. L-0 O I Pro Osed Slte Plan I .�Iu.ms F>� �° TK.WDYWLIK L:S Sala 1'=10' .m Glenn Goldsmith,President ®? s®U�� Town Hall Annex ® 54375 Route 25 A.Nicholas Krupski,Vice President P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly G Telephone(631) 765-1892 Elizabeth Peeples a® Fax(631) 765-6641 BOARD OF TOWN TRUSTEES June 16, 2022 TOWN OF SOUTHOLD Robert E. Herrmann En-Consultants 1319 North Sea Road Southampton, NY 11968 RE: PECONIC RIVER,.LLC 450 BASIN ROAD, SOUTHOLD SCTM#: 1000-81-1-18.1 Dear Mr. Herrmann: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, June.15, 2022. RESOLVED that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#9930 for the landward relocation and reduction in size of the approved dwelling and swimming pool, specifically to demolish existing two-story, 2,300 sf, FEMA-noncompliant, single-family dwelling with 460 sf attached deck and 761 sf detached garage, and construct at least +27 feet farther landward a new 1 to 2-story, 2,350 sf, FEMA- compliant, single-family dwelling with 16 sf and 17 sf entry porches, 1,402 sf attached pool deck with 4.7' x 14'steps and associated retaining walls, 681 sf swimming pool (equipped with saltwater filtration system), and 669 sf attached north deck; remove existing nonconforming septic system located +42'from bulkhead, and install new I A OWTS sanitary system outside Chapter 275 jurisdiction; install a drainage system of drywells to collect and recharge roof runoff and pool backwash; install new pervious gravel driveway and parking areas; remove specified trees located no closer than +69 feet from bulkhead; and establish a 27' to 39' wide, approximately 5,959 sf buffer area adjacent to bulkhead, including existing 4,259 sf naturally vegetated embankment and additional 10'wide, +1,700 sf non-turf buffer in place of existing lawn along top of bank; and as depicted on the site plan prepared by Kevin O'Sullivan &Assoc., LLC, last dated June 10, 2022 and stamped approved on June 15, 2022. The Permittee is required to provide evidence that a copy of this Trustee permit has been recorded with the Suffolk County Clerk's Office as a notice covenant and deed restriction to the deed of the subject parcel. Such evidence shall be provided within ninety (90) calendar days of issuance of this permit. BUILDING INFORMATION: �bt SBUTNOLO BAY Private 450 Bazin Roatl N88.5730•EdB9T ,pS �""a0smwa.` SIItMld,NY 11971 Residence Tas MaP ID: 100DB1-1-78.1 'L S BY4756•E B 450 Basin Road Zoning D'aWcl: Mg SIIWd.NY 11971 Lot Area: 32.665 If.(0.75 eves) 823' - - .,..�, All—bl.Lot cow:rage: 6.533 sf(20%of LOt A,ea) :.g_ .. I g' � 1Oi •uaxrm=...... Ai,e o,man EMSTtNG M 3W sl. G x swmp.x.mwu=u,w - :F;{'n4^"W Y I$tl e I 1F7.>me Ih Ho 2,use' a g,: 761,l.x „Gr"f, sunvEYOR De - 460.1.x EP1Wy Total Lola ,Mqe: 3.521 sf.2=10.8% ' 17, PROPOSED: r ->`'1 —+ ,y "'�•✓ %`� �x '� t I r�a�np4xsnm Main House 2,350 Pool De k: 1,402 If. North Da Jh(BBO) 6695f. i % m $ pucaoF uisnxo uwx N EX o'i , �^rr ams.s Envy Poch: 33 If.S. T.Il LIt Pool 135 s1. £ l P- a e I � New Thal lnl COWsega: 5,135 siv 1ST% d 'f € Ail—ble GFA: WA Fm°�u tivwy g lC,-7 L'_��• �4P.°.`�J ,., %..�:r� Proposed B idln9 GFA: eF Nun a b 1 a 4. 8. m 1st Floor: 2,350 If. "'•Bw S� -["' �' $�` _. 7 2nd Floor. 1,256.1. ,000si.,.Ie.r • • , ¢ ToW 9u1din9 GFA: 3,606.1. '`�,� _ •may' �e`Ty ' - ���ia� ' "" _-. APPROVED BY OF TRUSTEES T OWN OF 50 UTHOID ,.swrtARr srslEM uwoRMAnox,sEE pxprozEosEpnc o[srctrlaxvar LOOI ` r1�6*S o�uxoao Anoaaws Eeews6waa FaaAogm«eu oarals. j ' ON BOUNDARY \E(EL 21)Y C D ZON T - ,r :.s,rF waueAsso oM svmErpREPAaEo aBOUNDARYI y -- °:J( ------- --------nm°m----- ---- = ---umuw- p...c.ows1 Ir _ DATE paoFEmarnu°ALuw zurvEmmANo o6sra+ 70R'E % 5au.w smm..nrsrsrEN NFaawrroH: Yo* w.po-4m ______-0v- - FFriaum _ ___-C________________ 1 wno.n.seal Dw•a 4hAe+n sr -i M1 F I LM. M s.a mem°�u I � NwmgE,mprem, __ ________-__ r l\ u.q a.=N� Fwre I ' v c C 16 94E AO Hl. 4; �EopEM,W s X ro eE aEmopFo / roR,.,wm E�pnm.e TEST HOLE DATA ` ` e' •I\' -1 1 r / tyre:F.la.xsm I423•E i \ 1, 1 EL17.0 '0.0 `4. \ -�\\ C�/ d Redesign n5.p9207z BROWN SANDY LBMILI(M \ [`.n OA'BROWNLOAMYSANDB REVISIONS: SM GRAMEL( ) -B 2.8' �°+y ` ���- DATE:J-10.2ROWN MEDIUM SAND 022 ANOGRAVEI(SP) "� WaTER� m��l[u -MEDIUM SAND AND ' _ � n p—wxrF� y I SCALE:As Noted G' DRAWING TTLE 15.4' 'ia I ;j / Proposed Silo Plen -WATER SANG 6 GRAVEL(SP) 170 B'LSryRD 17B qB, � N= � �EV DRAMANG NUMBER:COMMENTS:GROUND WATER ENCOUNTERED 3)BL-001 AT16.4'BELB.GRADE a:1aTEST HOLEBY: style:l'=10' °KWOYCHUK LS /.� •��a ii G ioQ'p °FV°~Ci' = p', S•.. __ _. .�i�.,Y,i-^ 6,t .r � J '.>�."•.9't's• .,+.e alidfi• .•e ppllQ' 19°l'y�T;., pj.0'<, iVap°;a- ;•`'p14• 'i°P'a,�i•':� wr\ 7 .•''"�y, _%'"...,��` �y ° - u,,,cu,yr 1•���. - "• qy,6 .-\" , ' ..Y ' y"✓�w� 4u.. „V\� �' -w,W.l.^I��� ���•t.• '."°'�\/,� tiY to i�11 �•. I(fy � e\.t. � JF'-a. .�a• ry ., ,'�a _ �, .,�`i. :�{i.�� r .I•;;.�•, _�� '': o .,;`=R,k:"P .l`r��;g,.., ,.So,�,an,nnnasc:9?+:Y•�.yrL•u•'�:Tl•':.'':rSe,�nn ��y:.,n.yn�..;ew �.�r, ,y,.4�ym�i�..n,iunnnm.yqr.nngnrtn��ann..uryl,n,q:nr,..rm Zny�cur�u....r,.�n,nr:•:'.^r;7nut2YB�}r _aa; ,u lr E BOARD OF SOUTHOLD TOWN TRUSTEES r SOUTHOLD,NEW YORK ' i a PERMIT NO.9930 DATE: JUKE 16,2021 ISSUED TO: PECONIC RIVER,LLC 3 '° PROPERTY ADDRESS: 450 BASIN ROAD,SOUTHOLD =-/�• :r60 SCTM#1000-81-1-18.1 " AUTHORIZATION oeQ' Pursuant to the provisions of Chapter 275 of the Town Code of the Town of Southold and in 7 accordance with the Resolution of the Board of Trustees adopted at the meeting held on June 16, 2021, and in 1 �° consideration of application fee in the sum of$250.00 paid by Peconic River. LLC and subject to the Terms l k ` and Conditions as stated in the Resolution, the Southold Town Board of Trustees authorizes and permits the E following: z Wetland Permit demolish existing two-story,2,300 sf,FEMA-noncompliant,single-family dwelling with a; 460 sf attached deck and 761 sf detached garage;and construct at least+17 feet farther landward a new z one to two-story,3,200 sf,FEMA-compliant,single-family dwelling with 106 sf entry porch,945 sf e attached deck,850 sf attached garage,850 sf swimming pool(equipped with saltwater filtration system), 580 sf structurally detached deck,and Tx 46'uncovered basement egress;install pool enclosure fencing a x with gates; remove existing nonconforming septic system located+/-42' from bulkhead,and install new I/A OWTS sanitary system outside Chapter 275 jurisdiction; install a drainage system of drywells to collect and recharge roof runoff and pool backwash; install new pervious gravel driveway and parking ' °f areas; remove specified trees located no closer than+/-69 feet from bulkhead;and establish and perpetually maintain a 27'to 39'wide,approximately 5,959 sf buffer area adjacent to bulkhead, rig including existing 4,259 sf naturally vegetated embankment and additional 101 wide,±1,700 sf non-turf J r� F, r 00• buffer to be established in place of existing lawn along top of bank;with the condition of the use of stainless steel hardware on the detached portion of the deck;all as depicted on the site plan prepared by I P•$3: ,"' Kevin O'Sullivan&Assoc.,LLC,Iast dated June 4,2021 and stamped approved on June 16,2021. 'C IN WITNESS WHEREOF,the said Board of Trustees hereby causes its Corporate Sea]to be affixed, and these - aa presents to be subscribed by a majority of the said Board as of the 16th day of June,2021. :.la<a �OgpFFO��- lv. ca 0 r kbd �`1,Qga -.I ii�ii neraa„r.,, as,cra,:v,aan.mU, rar. ..,,,r:R;nr .,a; .4"Cv9r•ei,itL..a,d4{7:,�• ei,Juifiy7w.nnsa.ru.cm Nr,:aas,,... w�,,.vra ¢h. smt•...:•„r..rA WSS"'.s.r••....ra........a.s..e '•� •\;cam 4 5�,:1..f'Y.. r° r I \, �`�� p w✓/ `s', pa. .a' p 0,. .°�� fie. s067 l,e —.'r••u�� �1:,. - •t a liar 4! a9,, _ GI Q1�•, '.i.a` 'VOp,,. � r16,.. t....:c! i9• esiiti?ire.... ` M1�a.. •,n taa Q.ea:' ,�,b„�,::•• .•,ai4 r' ro QrQ.,.-'_ ifi, .,( �e•�• BUILDING INFORMATION: d E6. uY.1 NB9'5796'E46W SOUINOLDmy Private :k1,1 15D Beat.Roan 'f�- �' Residence pp ..O _r'._--_-- SeuNdd.NY119]1 A, Ta,Map to. 1UDD61.1-18.1 `=__ -___ — i_--- � _ _ Sa2.4r5,-E99.gg• PECONIC RIVER,LLC, 2a.N9 Dsmm Rm a 88.1504.IN y° i _ 450 Basin Rd - Lot Area: 32,665 al.(0.75 apes) - 633' _ _ /' !;1 SODUIDId NY 11971 La care age r�alat�. ^^� __ __ -- hw.R.:+wwa __ I _a• AAwren _= Allowade lelCwerzBe. 6.533 111(211%of btArea) ( ; c � �- I I ,•� _�_aA�_ EXISTING: o,nrams G-gru 23o0761 6:s mveruru9wu¢m.wu. 1 .` v..r^.'f -i+ Delta: O6D I,t y 1 Y•.ly Eakong Tow Lot Coverage: 3,521 eL 1em 109Y PROPOSED. MaN House 3.21)D St. •. I ' t F 1 `1_ L pzpp t amuc',uuLsxra�n AoageO 945 1. ll. Pool Da 0 945 s1. e' -y, yg g�1 >uce oc cvs•p..urm Ji x I- $j Naryt Slam. �vw�I. ):e �1�' €; :�F t�• a � it �3 I a�'^.vraa NM Do h Dog(Boo): woe. swimming Pad: 531 all New Tow Lot Coverage: 6,531 a1=19.99Y. Plowable GFA MA ,aroatnns.r { t. T' P,opcseE BvUuv GFA 1.1 Fb ],265 sl ' y 2nd Floor. _1 2 2 si To. BUJEmg GFA: 4"R - I / r J1 t 'l,esumq y,- � I .euoonrr,3,atw.1 I e p ul "'..el n9tl.e�e�a. I APPROVtt 1 -- - -.__,__ BOARD OF TRUSTEES TOWN OF SOUTHOID PwaaDA...w i �./ I � ?_ / I �I�..i ICI�-{ i,J4_________}________ �'�' _._ } DATE TJY9 IG,�zt A,4 \1 r Emmq a, EMEDAIL. - tone nwveu re nymo a7, r__ eIFNaN _1 , =_i(♦ Ftl� / F pWy 1 A ms.r sYam- \ 1`L* f `•r rJ J• r w J Z S ��°. viE—FeeLE OATA e,...v.ry l r11c LY�I�D EL:1T.V DP eb.o / JLa 11 "Fe^d^9 -BROWNSANDYLOAM IMLI �y�'•. t II-`-x �1 D AROWN LOAMY SAND a t / ! _ ^^e ` REVISIONS: GRAVEL ISM) 2:-BAN ROWN MEDIUM SAND - -_y:O Etc-- 6�v�4Gp _.- DATE:Atoll 11,2021 6 D GRAVEL(SP) Ea SAN - -.. SCALE:Pa Notetl -MEDIUM D AND GRAVEL(SPI _ eihij.�mnyw b DRAWING TITLE EL:1.9 —__15./' —._-__ 0•n, ` I FIDp—d St.Plan -WATERSANDILGRAVELISP) I79,9B• ` 37 2 / DRAWING NUMBER C 25,a.NELOW GROUND WATERENCOUNTERED --- - 61 m I AT 15A'BELOW GRADE � \`"-=.w., �Lw+mgb a `—oo1 Proposed Site Plan TESTHOLEBY: a.,.a'=1Du- KWOYCNUKLS r we'RO ED AS NOTED FEE B,r: NOTI BUILDING DEPARTMENT AT 631 765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF D SOUTHOLD TOWN TRUSTEES ��.�.-.N.YS.DEC �SO[J�H0 H_PC SCR RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Untitled Map Legend Write a description for your map. 36103C " 450 Baisin Rd ---- Residence ti. ♦ w \• oil *# - AN jo . 1, 'y •� � � ' • 1 ♦ � �� '• i k 174 1t-� +'�� ti Safi 4�►�. 7 1 `L '... ,° � "'•.. � !�� ;� ;• � � •� `fit {• ft+,I qP 1 � � e � •.� 4 c.t x" t �•