Loading...
HomeMy WebLinkAbout52750-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52750 Date: 03/12/2026 Permission is hereby granted to: Greenport Group LLC PO BOX 1000 Woodbury, NY 11797 To: Unit 4-Legalize as built interior alterations to a commercial apartment to create a two-bedroom unit as applied for. Premises Located at: 920 Chapel Ln, Greenport, NY 11944 SCTM#45.-2-10.5 Pursuant to application dated 01/23/2025 and approved by the Building Inspector. To expire on 03/11/2028. Contractors: Required Inspections: DRAINAGE, FOOTING/REBAR, FOUNDATION 1ST, FOUNDATION 2ND, FRAMING/STRAPPING, PLUMBING, ELECTRICAL- ROUGH, FIRE RESISTANT PENETRATION, ELECTRICAL-FINAL, INSULATION, FIRE SAFETY INSPECTION , FIRE RESISTANT CONSTRUCTION , FINAL, Fees: As Built Commercial $984.00 CO Commercial-Addition/Alteration $100.00 Total $1,084.00 '-I:�J) Building Inspector �� ru�r:r�t TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 "i, «► Telephone (631) 765-1802 Fax (631) 765-9502 hti, iw � ^_ etticicicrla ° Date Received APPLICATION FOR BUILDING PERMIT VLa For Office Use Only PERMIT N0.a r7�.� Building Inspector. �. ... 2 3 L-2 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 'S OWNER(S)OF PROPERTY: f o SCTM # 1000- 9 Project Address: �f -1� Phone#: Email � _.. w Mailing Address: oo _. CONTACT PERSON: Name: Mailing Address: Phone#: r...) - �>-112 Emai DESIGN PROFESSIONAL INFORMATION: Name: � . — Mailing Address:2 _/ . t _ Phone#: Email: CONTRACTOR INFORMATION — Name: -� Gd Mailing Address: Phone#: .., _ Erna' i DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Struct re ❑Add¢I'on :]Alteration epair []Demolition Estimated Cast of Project: Will the lot be re-graded? ❑YeSA. o Will excess fill be removed from premises? ❑Yes Azle 1 PROPERTY INFORMATION Existing use of property: Intended use of property: — o:n or use d 'istr vOich mises is situated: Are there any covenants and restrictions with respect to i JL this property? ❑Yes o IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/oontracUar/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town code. APPUCATION IS HEREBY MARE to the Department for the issuance of a Building Permit pursuantto the Building Zone ordinance of the Town of Southold,Suffolk;county,Neal'"ork and other applicable Laws,ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on'premises and in buflding(s)for necessary inspections,false statements made herein are punishable as a Class'A misdemeanor pursuant to Section 210.45 of the New York state Penal law. Application Submitted Byg(priname : reuthorized Agent ❑Owner Signature of Applicant -- Date: STATE OF NEW YORK) COU TY OF pr't�T�' 't��J eing duly sworn, deposes and says that (s)he is the applicant (Na a of individual signing c ntract) above named, (S)he is the (Contracto Agent, �have e Officer, etc.) of said owner or owners, and is duly au o pe orm orpelMfirmedthe said work and to make and file this application;that all statements contained in this application are tru�to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the applicat'ian.fale therewith. Sworntbefore me this YLYay of 20 4" otaA*ft43 Gblir-State Y r No.Ol MA 354 0 Qualified in Suffolk linty PROPERTY O!WNE t/THORIZATION fly Commission Cxp,02 112095 (Where the applicant is not the owner) A e p, ,residing at i wwdo hereby authorize to apply on my behalf to the Tow94 Southold Building Department for approval as described eret wnAwner'sKame ' t re to P int mm 2 r ,r PB 14 L- MT Bc�'me i�� ry SITE PLAN USE DETE�A!TION� �� 5 ➢li, S' J�T6�P ��'P�"0 Initial Determination wq.A� ���r�a°»an, aO Date Sent U�� 2- Date: G3 �9 /s5 �.,.w Cw ' LL_G _._..._.._........ � _......_..... Project Name: 11 " ��"" __.... .. ,. �. £ w ..., ._ Project Address. _..._wc.� ? ._ :.. _...._ Suffolk County Tax Map No.. 100 �J_ 0 I D, 5 Zoning District: Request: Le C-L.z ___ .. (NoteCopy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) Initial Determination as to whether use is permitted: —---•-------" hether site n as tow plan is required Initial Determination p : �...w..__.�..._......._ .._.,.. �___._..�... .__" .... ,.��._.._..� ._..... ___ n spect oc' d Signatu reo uildingl Yw._-___ __ --- I, Planning Department (P.D.) Referral: ......,_.__..r.. w........_ ......... Date of Comment: P.D. Date Received: Comments°.�_� �cett �" � rtc'�.��°i " J Signature of Planning Dept. Staff Revie r 4 6 Fina"I Determination Date: Decision'__w_. Signature of Building Inspector , rr r � r ril /I/ii/%l,rl/, a�riuiu rnmr�r r ,,� r �r,, ..a r/.1i/r�1/�/i/%/%�//U%//�l6r�l//////�//Hll/d✓7y/�;�11�r1Nr< �))�6/li,l// nrr�meo�„ro,�r�oiii rr i r✓ � rr,ii ii r�i�l✓�o�rlii�i�e,ii�„oprtr���atl�a�r�s�yii�,�ii�r l V l TOWN OF SOUTHOLD BUILD&G �EPT w 631-765-1802 �'�. p. j INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING ] FRAMING / STRAPPING [ F AL ] FIREPLACE & CHIMNEY [ FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ECTRICAL (ROUGH) [ ] ELECTRICAL (FI AL) [ CODE VIOLATION [ ] PRE C/O [ RENTAL • Lk4,.-- CA A wv .w.._-_ 0_4� 'vim -- DATE INSPECTOR � 8® March V12026 Suffolk County Department of Health Services " 360 Yaphank Avenue �RD"IVfir Yaphank,NY 11980 Tot: (MI DI`- 2" Fox: ( 1)47' ►-1$77 RE: GREENPORT GROUP LLC villaveotoroonvortam 920 CHAPEL LANE, GREENPORT NY 11944 TAX MAP IN MAYOR 1000-045.00-02.00-010.005 KEVIN 571 EXT 215 To whom it may concern: TRUNT114S The possibility of sanitary sewers, appurtenances, and sewage disposal facilities PA MUCK a for the above-referenced 1 have been inspected b the Green Sewer District DEPl11Y�„ �� P Y P� (the "District")and the district hereby confirms that it currently has the capacity to service the extant 8 units on the property, each consisting of 2 bedrooms and 1 Kaxy vss pHnAps bathroom. Please note that any changes to the property that could result in an expansion of sewer usage shall require prior notice to and reinspection by the Village and any alterations to existing or new sewer connections shall require first obtaining a LILY DOUGMIY-JOHNSON permit from the Village. If I can be of any further assistance,please contact me at(631)477-0248 JULIA ROBINS Regards, VILLA"CLIRK CANDACE HALL EXT 214 Adam Hubbard Village of Greenport Waste Water Treatment Plant Ernesto Rosini,RE, Engineering Consulting Services P.C. ERNESTO ROSIN[, P.E. 9 Leonard Street ENGINEERING SERVICE P.C. Wading Rivet-, NY 11792 Uh 7'el 631-680-2485 ernestrosiniftmail.com Date:April 16, 2025 Southold Town Building Department 53095 Route 25 PO Box 1179 Southold,NY 11971 Re: Wastewater Load Evaluation—920 Chapel Lane, Greenport, NY 11944 Greenport Group LLC Tax Map ID number: 1000-045.00-02.00-010.005 920 Chapel Lane Greenport NY 11944 Dear Sir or Madam, This letter is to inform you that I have been retained by the property owner of the referenced project located at 920 Chapel Lane, Greenport,NY 11944 to provide professional engineering services related to wastewater load calculations. The owner is proposing to convert eight (8) existing one-bedroom cottages into eight (8) two-bedroom cottages. In reviewing the historical engineering report prepared by Michael Chiarelli, P.E., of Huntington Station, NY, dated November 2012, it is noted that the current sewage disposal system was designed for eight units (each>1,200 sq. ft.) at a capacity of 300 gallons per day (GPD)per unit. That report also indicates that two-bedroom units require 220 GPD. Based on this information, it is clear that the system's original design capacity of 2,400 GPD (8 units x 300 GPD) is sufficient to accommodate the proposed conversion. The total projected wastewater load for the proposed eight two-bedroom cottages is 1,760 GPD (8 units x 220 GPD), resulting in an additional wastewater load of 880 GPD compared to the existing usage. As a Licensed Professional Engineer in the State of New York(License No. 094477), 1 have reviewed the proposed changes and confirm that the existing system has adequate capacity to handle the increased load. Therefore, no upgrades to the existing sewer connection are necessary as a result of this proposed conversion. Should you require any additional information or documentation, please do not hesitate to contact me: Sincerely, oF New Ernesto Rosini, P.E. Licensed Professional Engineer—NY License No. 094477 SAN SIMEON PI1:1' P STATION TOWN OF SOUT TOLD, NEW YORK ENGINEERING REPORT FOR REFURBISHMENT OF SAN SIMEON PUMP STATION GREENPORT GROUP LLC Michael P. Chiarrelll E neer. P.C. w 1954 NEW O A E HUNTINGTON STATION,NEW YORK 11746-29N TEL (631)673.3M FAX (631)673.3842 REVISED NOVEMBER 2012 REVISED MARCH 2012 REVISED FEBRUA.RY 2012 VISED JANUARY 2012 REVISED NOVEMBER 2011 AUGUST 2011 FCTIO►N III PUMP STATION CAPACITY SANITARY SE E ELOW The average daily design flow for sewage is the average of the daily volumes of sewage to be pumped for a continuous twelve!(12)month period. i The average daily design flow �or the proposed refurbishment of the Pump Station is derived as follows: i A. aewgn kjow —4$ Pipe Minimum The existing force main is 4" diameter, approximately 1,400 feet long and terminates at the Greenport Sewage Treatment Plant. SCDHS standards require a minimum velocilry of 2 fps in the pipe at all times. Therefore, the minimum pumping rate is 78.17 gprn or 112,565 gpd as shown in the following calculation: G Q = V x A = 2 L x.08725 f t� _ .1745 3 sec = 78.17 gpm B. Flow fMRS andaEd The original design was for a 150 cottage type retirement community. However, the pump station ° my serves the existing 8 cottage type houses and a church. The standard design ow criteria of the SCDHS is based upon the type, number and size of units and generates an average daily design flow as follows: i 1�.p In G Flow nit " `oWlr W 8 cottages x 300 gpd (>1,200 sq.ft.) = 2�,400 gpd 450 seat church x 4 gpd/seat = 1,800 dad TOTAL. _ " p► BEAK FLlO�I SVD 13-PON 43 V FACTOR = 18,0W gpd 5 ..." ivllchulP.(�iacelliEo�inee�+p.G `'' Peaking factor is�established by criteria established in Ten States Standards. 18 + 18.236 4.3 i 4.236 C. Sellaaeffiw—Siimmarj of AnalMs A summary of th various techniques for estimating the sewage flow as related to the pump station s as follows: 1. 4" existing force main (to maintain velocity of 2 fps) 112,565 gpd . SCDHS design criteria: 18,060 gpd D. Basis of efb t 12g§igg Flow The basis for this refurbishment design flow shall be taken as the maximum of the calculated flows listed above, which is 112,565 gpd. i E. i' w. Based upon the existing conditions of the site, the calculated peak flow will be 12.54 gpm (18,0�0 gpd _ 1,440 min/day), which is well below the 78.17 gpm flow required to maintain a 2 fps minimum carrying velocity through the existing 4"force main. Therefore, the peak flow used will be 78.17 gpm. f The basis of design for the proposed refurbishment of the pump station is 78.17 gpm and all calculations in this report address the requirements for the pump I station to deliver 48.17 gpm. I i i i Michael P.Chiarelli Enginmr,P.C. 6 San Simeon Pump Station Job#319-001-10 Greenport Group Aerial view showing existing sanitary pumping station and force main locations SECTION 7—PUMP STATION BASIS OF DESIGN......... 1. Average Daily Deli n E12w Criteria: The average daily design flow for the development using established SCDHS criteria, based on the original approved retirement home community is presented in Table No. 7-1 below: TABLE NO.7— 1 ORIGINIAL AVERAGE DAILY DESIGN FLOW � ,,.. .....__ ... ..._USAGE QUANTITY 'UNIT I DFSI:C.:. N FLOW AVERAGE FLOW A 1 -Bedroom Units 134 Units _1p00wG s, Nnit 12,400 Gals./Day 2-Bedroom Units 26 Unitis 225 Ga1s.ID�/Utut 5�800 Gals./Da N1lrsi Beds 8413eds T I /l$OGals-1P ed 12 600 GalsJDa Motel Units nits 100 Gals./Da 1.5 Gals./Capita Not Included Total !POLOFlow ...._ _...wM......_.. .. 1I /Il ,._ .,.. 2. Peak.Daily Deligg Flow `xitgria: A. Population Equivalent: Design Criteria: 75 gals./day/person Population;---31,700 gals./day/75 gals./day/person Population=422.1 people Say 423 people B. Peak Hour Flow Rate Factor(f peak): f peak=(18+ �P) / (4+-VIP) fpeak=(18+ q.423) / (4 +-4.423) = l ±0,65: 4 +0.65 f peak= 18.65 = 4.0107 Say 4.02 4.65 C. Peak Flow Rate(Q peak): Q peak= fpeak x Average Daily Flow/1,440 Minutes/.Day Q peak=4.02 x 31,700 Gals./Day/1,440 Minutes/Day Q peak=92.4 Gals./Minute 3. Puing Station Design: A. Criteria: Minimum wet well capacity 30 minutes detention @ average daily flow. P.W.Grosser Consulting, Inc• P.W. Grosser Consulting Engineer&Hydrogeologist, PC 9 630 Johnson Avenue, Suite 7• Bohemia, NY 11716 PH 631.SB9.6353• FX 631.589.8705 • www.pwgrosser.corn New York, NY • Seattle, WA• Greensboro, NC B. Minimum Required Wet Well Capacity: Minimum Wet Well Capacity = l; 70t �rals,/l: a x 10 Mitttttes 1,440 Minutes/Day Minimum Wet Well Capacity =660.4 Gallons Say 660 Gallons C. Existing Wet Well Size: T-2"diameter precast concrete wet well with interior diameter of 6'-0" D. Existing Wet Well Effective Depth: Minimum Effective Depth= 660 Gals./7.49_ialsd u.FL/. Ca om' S FFt.; 4 Minimum Effective Depth=3.12 feet Say 3'-2" Existing Wet Well Depth: (Based on plans of HZM Consulting Engineers on file at the office of the SCDHS): Existing Low Water Level = (-) 2.87 Existing High Water Level = + 079 Existing Effective Depth 3.66 feet=3'- 8" E. Existing Wet Well Depth Characterizes. Existing Wet Well Characteristic: (Based on plans of H2M Consulting Engineers on file at the office of the SCDHS): A. Top Slab Elev. — +10.3 B. Invert Elevation of Influent Sewer Elev. - + 2.09 C. High High Water Alarm Elev. = None specified D. High Water Alarm Elev. — + 0.79 E. Both Pump on Elev. 0.00 F. Lead Pump On Elev. — (-)1.00 G. Both Pumps Off Elev. — (-)2.87 H. Low Water Level Alarm Elev. None provided 1. Low Low Water Level Alaxnl — None provided J. Bottom of Wet Well (-)3.37 K. Bottom Elevation of Base Slab Elev. (-)4,05 Total Height of Wet Well 110.30—(-}3.371 = 13.67 feet P.W. Grosser Consulting, Inc-P.W.Grosser Consulting Engineer&Hydrogeologist, PC 10 630 Johnson Avenue, Suite 7 - Bohemia, NY 11716 PH 631.589.6353- FX 631.SSg.87o5 - www.pwgrosser.com New York, NY -Seattle, WA - Greensboro, NC 4. J!"oyancy Lal'ulatidrns: The design report for the pump station prepared by HzM Consulting Engineers on file at the office of the SCDHS made no mention of buoyancy, in spite of the fact that the bottom of the station wet well was at elevation (—) 4.05. The SCDHS raised this issue in a letter dated October 24, 1984, however the design engineer responded that calculations were made and " it was determined that ground water would not cause a buoyancy effect on the structure." A. Design Maximum 100 Year Elevation: 11.0 + 1.0 foot or elevation 12.0 (See Section 6.0 for data on 100 year flood elevations and datum's in area immediately around the station. B. Minimum Top Slab Elevation: Use elevation 12.0 for required minimum top slab elevation of station. C. Existing Uplift Forces(full submergence): Uplift Force=jr( 7'-2" )Z x( 14.35' ) x 62.4 Lbs./Cf. 4 Uplift Force=36,035 Lbs. D. Existing Down Forces(weight of empty structure): Down Forces=weight of(top slab+bottom slab+ walls) Down Forces=(n)( 7'- 2,)` x 0.67' x 150 LbsJCf. =4,038 Top Slab 0'-8" 4 +( j2L- "j1 x 0.67' x 150 Lbs/Cf. =4,045 Bottom Slab 0'-8— 4 n 7'-2 -"— rt fa" _g::] x 13.0 Ft. x 150 Lbs./Cf.=23,361 Wet Well Wall 0' 7" 4 4 Down Forces =31,444 Lbs. Net Up Lift Force=36,035 Lbs. —31,444 Lbs.=4,591 Lbs. Currently there is a deficiency of 4,591 Lbs. It is proposed to correct this deficiency by raising the top slab about 2'-6" at a new top slab elevation of 10.3+2.5= 12,8,hereby the following revised calculations would apply: E. Anticipated Uplift Forces (full submergence elevated top slab): Uplift Force=a 7'-2" z x ( 16.05')x 62.4 Lbs./Cf. 4 Uplift Force=40,304 Lbs. V Proposed Down Forces (weight of empty structure elevated top slab): P.W.Grosser Consulting, Inc•P.W. Grosser Consulting Engineer&Hydrogeologist,PC 11 630 Johnson Avenue,Suite 7 • Bohemia, NY 11716 PH 631.58M353 • FY, 631,589,8705• www.pwgrosser.com New York, NY• Seattle, WA• Greensboro, NC Down Forces=weight of(top slab I-bottom slab+walls) Down Forces= x T-2")' x 2.00 x 150 Lbs. = 12,054 New Top Slab 2'-0" 4 + x 0.67' x 150 Lbs./Cf. = 4,045 Bottom Slab 0'-8" 4 7'-2 '— Ci'- t),'',) x 14.16' x 150 Lbs./Cf. =25,446 Wet Well Wall 0'-5" 4 4 Down Forces =41,545 Lbs. 41,545 Lbs.Downward forces are greater than uplift forces of 40,304 Lbs, OK 5. umg S a. A. Minimum Pump Size Criteria: Minimum Capacity =maximum flow rate B. Design Maximum Flow Rate: Maximum flow rate=92.4 Gals./Minute 6, Foreg L4gllj&W P tri as: A. Force Main: Existing 4"O"Ductile Iron Force Main 1.) Static Head: High Point Elevation: — 46.77' Pump Shut Off Elevation — (-)2.87' Static Head — 46.77—(-)2.87=49.64 Ft. 2.) Dynamic Head: Interior Diameter Pipe :`'D" — 4,0"inside diameter Coeff.of Friction"C": — 120(30 years old) Pipe Length: — 1,400 Ft. Equivalent lengths of: Bends 90 deg.(3 @ 9') = 27 Ft. Bends 45 deg.(2 @ 5') — 10 Ft. Check Valve(1 @25') — 25 Ft. Plug Valve(1 @ 10') — 10 Ft. Total Equivalent Length — 1,472 Ft. Say 1,500 Ft. P.W. Grosser Consulting, Inc•P.W. Grosser Consulting Engineer&Hydrogeologist, PC 12 630 Johnson Avenue, Suite 7 - Bohemia, NY 11716 PH 631.589,6353 • FX 631.569.8705 • www.pwgrosser,com New York, NY •Seattle, WA • Greensboro, NC Hl,Head Loss Using Flaw-Williams Formula: HI,Read Loss (10.44 x L x(,V,P,.,)"' C1 85 x HL Head Loss= (10.44 x 1500 x(V,,T, 1 85 120185 x (4,,,kj4-g655 Pump Capacity Analysis 160 140 120 100 80 —W.,Pump Curve 60 40 20 0 0 so 100 150 200 250 300 350 Flow(GPM) 5.) Pump Operating Point: Pump Design Point=90+Gals./Minute @ 61 TDH (26.41 LbsJSq-In.) 6.) Surge Pressure Calculation: Velocity of Pressure Wave(Ft./Sec.) a=L i (I--[(k,`E)x(&t)x C 1 1) a=L/y(I-v[(313,000y;33,000,000)x(4/34 x I P.W. Grosser Consulting, Inc- P W. Crosser Consulting Engineer& Hydrogedogist, PC 13 630)ohnson Avenue, Suite 7 - Bohemia, NY 11716 PH 631 589,6353 - FX 631.589.8705 . www.pwgros5Lr,com New York, NY- Seattle, WA- Greensboro, NC a= 150011,1115858 a= 1,350 RiSec. when; k=modulus of water compressibility 313,000,psi at 60'F d=pipe inside diameter 4.00 In. E=modulus of elasticity of ductile iron pipe 33,000,000 Lbs./Sq.1n. t=minimum pipe wall thickness 0.34 In. C, = pipe constraint constant 1.0 Critical Time of Travel of Pressure Wave(seconds) TCR=2L/a =2 x 1,500/1,350=2.222 seconds where L=length of Force main 1,500 Ft, a=velocity of pressure wave 1,350 Ft./Sep:. Maximum Surge Pressures.(Lbs./sq. In.) hMAx=aV/g = 1,350 x 2.36/32.2=19.99 Feet(6.20 lbs./Sq.ln.) where a=velocity of pressure wave 1,350 Ft./Sec. V=velrvity of liquid in pipe 2.36 FtJSec, g=gravity acceleration 32.2 Ft./Sec./Sec. Total Pressure Exerted on Force:Main(psi) Maximum Surge Pressure =hr.,,x =19.89 Feet equivalent to 6.02 Lbs./Sq.ln. Pressure Head at Pumping.Station=TDH =61.56 Feet equivalent to 26, 5, Lbs„/S .Im Total Maximurn l"ressure = 32.67 I..bsJSq3I - Class 150 pipe ductile iron pipe is rated for 2,500 Lbs./Sq.ln.burst pressure less than 32.67 OK. 7. Qjj&nal And liep went Purn s» The original construction included the installation of two (2) submersible 3" solids handling pumps with rated minimum capacity of,105 Gals./Min. each at total discharge head of about 65 Ft. Pumps were Peabody Barnes,Model No.4SEH752, 1750 RPM with 7.75"impellers, single phase, 230 volt. In 2009 these pumps were replaced with two (2) new ABS Model No. EJ30D-4, 3 phase, 230 volts, 7.5 horsepower ABS 3" solids handling submersible pumps. These pumps are capable of handling the peak design flows. P.W. Grosser Consulting, Inc + P.W. Grosser Consulting Engineer& Hydrogeologist, PC 14 630 Johnson Avenue, Suite 7 + Bohemia, NY 11716 PH 631.589.6353 + FX 631.589.8705 + www.pwgrosser.com New York, NY+ Seattle, WA+ Greensboro, NC SECTION 2-DESCRIPTION OF SITE The(GG)pump station was formally referred to as the San Simeon Sewage Pump Station was approved by the Town of Southold in 1984. The gravity sewage collection systeern and pump station was approved by the Suffolk County Department of Health Services (Reference No C10-89-015) on December 1, 1985 for only eight (8) units. Permission to discharge sewage to the Village of Greenport Sewage Treatment Plant was granted to the owners(St. Peters Lutheran Church),by the New York State Department of Conservation and the Village of Greenport. As of July 1, 1990 the Village gave permission to the then owner of the property, San Simeon Properties Associates, percussion to discharge 3,600 gals./day of sewage into the Village collection system(the design flow of the proposed Phase I development). The current owners of the property and pump station, The Greenport Group, LLC, indicate that the original project approval has be rescinded, as the Town of Southold has up-maned the area for two (2) acre residential development. Under the two (2) acre zoning requirement the development potential of the parcel would be considerably reduced to about a total of twenty(20)residential tints,which in turn would significantly reduce the amount of sewage required to be conveyed to the Vi page of Greenport collection system. The site is generally flat with glades vary from a high elevation of about 28 AMSL in the northem and western portions of the property to about 10 AMSL along south east portion. Surface drainage is generally south and southeast towards un-drained areas of the properties located to the east and south of the property. P.W.Grosser consulting, Inc- P.W. Grosser Consulting Engineer&Hydrogeologist,PC 2 630 Johnson Avenue, Suite 7- Bohemia, NY 11716 PH 631.589.6353- FX 631.589.8705- www.pwgrosser.com New York, NY - Seattle, WA - Greensboro, NC . i °t SITC ❑C TTCN i tM1 1 - a YMI '� �. _ =.emu _v v � rjv� �_ APPROVED AS NOTED E �. �^ z � I �$�•{)Q BY:Cttl CC `iP:Y MTH A L COD 3O v � � � � N 'try YORK STATE&TOWNWCODES NOf3FY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF �31 765-1802 8AM TO 4PM FOR THE z n YOL1 ING INSPECTIONS: FOUNDATION-IF si TWO REQUIRED }-_ 3 SOL OR POURED CONCRETE = S} OI.DTu;MFd RUSE-Es E - ROUGH-FRAMING&PLUMBING N.Y.S.DEC - ='INSULATION �i�,T��',�roI;C �-d IFINAL-CONSTRUCTION MUST SCHD !BE COMPLETE FOR C.O. 0 o 0 ID iALL CONSTRUCTION SHALL MEET THE ;REQUIREMENTS OF THE CODES OF NEW ( ] iYOIK STATE. NOT RESPONSIBLE FOR ® z DESIGN OR CONSTRUCTION ERRORS �n A,�yy }Tonal Certifi cation I 3 121 j E dash f dry jap/ysD , MayI l ^� m2j I Am >z I ELECTRICAL — ; INSPECTION REQUIRED e ' zt SOY ill 1 a� 0 I 0 Q) g m co o z zr w =-I LL m 10'-8" Elec l0'-8 fi ...:... ..............................._.._........................... I 6' 10'-8 18'-3' f 1 Bed Living Room Room 13'-3' 13'-3" '5'-10" ® 5'-10' ® Rear t ......._ /L C3'-4' 3'-5' C/L Front13'-63'-3UNIT 3 ,� Bath _9 Bed 14'-6" 6,-2n -s° Room Kitchen ill-6' 2'-2' � 4'-11' U/.�- � O O � wh jL 5° EP stor. stor. O EP C/L C L " O O wh 9 _ -... 5 ®/T U-� n 2'-2' Kitchen Bed UNIT 4 Batn7'-9 A Room 14'-6" Front 13'-6" C/L C/L _6. 3'-5' 5'-10° 3'-4" 3, 5'-10°— , ® Rear 5'-10° 5'-10° Bed 13'-3' Room 13'-3' Living _.- Room 18'-3° .. . - � FLOOR PLAN 3/1 " = 1' Ernesto Rosini, P.E. Engineering Consulting P.C. JLT Team LLC 2042 N. County Rd Suite 105 920 Chapel Lane Greenport NY Wading River NY 11792 Residential FLOOR PLAN EE 631.680.2485 ernestorosiniOgmail.com I UNIT 3 & 4 Sri601 DMRiPilo4 I AnPNOYE� DATE DRAYfN BY DAZE i DWC SHEET N0. SCTM 1000-045.00-02.00-010.005 V I S I O N S ER 1 t 10 2025 b of 5