Loading...
HomeMy WebLinkAbout50640-Z hoy��°F s°urya`o Town of Southold * * P.O. Box 1179 o� 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46677 Date: 11/12/2025 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 625 Park Ave Mattituck, NY 11952 Sec/Block/Lot: 123.-1-6 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/05/2024 Pursuant to which Building Permit No. 50640 and dated: 05/08/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to: Solution East LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50640 9/05/2025 PLUMBERS CERTIFICATION: utho ' ed Sign ture SUF elF c, TOWN OF SOUTHOLD �o aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE Cn o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50640 Date: 5/8/2024 Permission is hereby granted to: Solution East LLC PO BOX 283 New Suffolk, NY 11956 To: construct accessory in-ground swimming pool as applied for. At premises located at: 625 Park Ave, Mattituck SCTM #473889 Sec/Block/Lot# 123.-1-6 Pursuant to application dated 3/5/2024 and approved by the Building Inspector. To expire on 11/7/2025. Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO- SWIMMING POOL $100.00 Total: $400.00 Building Inspector pF SO�jyQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Solution East LLC Address: 625 Park Ave City: Mattituck St: NY Zip: 11952 Building Permit#: 50640 Section: 123 Block: 1 Lot: 6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: K P Electrical - License No: 36533ME SITE DETAILS Office Use Only Indoor Basement r Service F Solar F Outdoor 1st Floor r Pool I✓ Spa r Renovation 2nd Floor f- Hot Tub F Generator f Survey Attic Garage rl Battery Storage (— INVENTORY Service 1 ph F Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph F Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 12 Circuit Pool Panel /6 Used, Pump 220GF1, Heater 120GFI, (3) Lights 30OW Trans 120GFI, Salt Gen 120GFI, Auto Cover w/ Keylocked Sw 120GFI, Waterbond Ionizer Notes: Pool Inspector Signature: X Date: September 5, 2025 Sean Devlin Electrical Inspector sean.devline—town.southold.ny.us 625ParkPool g SOUlhO6 # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 o INSPECTION [ OUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] .FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ]' FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ATE INSPECTOR OF SOUIyO� TOWN F—SGO�THOLD BOIL I G EPT. "cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] .FIREPLACE'& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 40 r f o DATE INSPECTOR 50UThO�o # TOWN OF SOUTHOLD BUILDING DEPT. lou � 631-765-1802 ,�wo INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I UL TION/CAULKING [ ] FRAMING /STRAPPING [ FINAL �,V [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 • IV CAO 4�C f zA f\ n A DATE INSPECTOR OF SO4TyOlo i v � # # T9N�OF SOUTHOLD BUILDING DEPT. "coum 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] ,FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR `` FIELD INSPECTION REPORT DATE COMMENTS v !� O r FOUNDATION (1ST) ------------------------------------ FOUNDATION(2ND) z �o H ROUGH FRAMING& PLUMBING r INSULATION PER N.Y. t� STATE ENERGY CODE M FINAL ADDITIONAL COMMENTS S• cl - 24 00 °% PCO re c.-*� 10 3 -1 C(ec� ),c- eat p-j-C 10 9 5- o Z �rn v N H rye H x d r� b ��o4°S�fFiu,t�ooy TOWN OF SOUTHOLD-BUILDING DEPARTMENT y, x Town Hall Annex 54375 Main Road P. 0, Box 1179 Southold,NY 11971-0959 �y�01 ao� Telephone(631) 7.65-1802 Fax.(631)765-9502hLtps://www.southoldtownny.gov Date'Received APPLICATION FOR BUILDING .PERMIT 'l d 1,i i— � ,. :[;::} � `•`. l^ For Office Use Only 1 PERMIT NO. Building Inspector: MAR 05 2024 r .r Applications arid`forms must be filled out In their`entirety Incomple`tea'x° s ap.phcatlors irvlll not be accepted>Where,thesApplicant is 606e owner, P Owner's Authorization form(Page 2j shall be completed �+ � '� - � ,... •, .."�=� .. z':. i �,a: d�.,.,.:� >."yt° +4 ,s..�.�;a„L�1 a f�,F.T� Date:March 23, 2024 n Name:SOlutlon East LLC SCTM# 1000-123-01-06 Project Address:625 Park Avenue, Mattituck, NY 11952 Phone#:917-584-4977 Email:annemarino440@gmail.com Mailing Address:PO Box 283 New Suffolk, Ny 11956 CONTACTER PSON n ac n •, °� ? '> ,E ` �" Name:Chuck Kitz Mailing Address:110 Eastside Ave., Mattituck, NY 11952 Phone#:516-971-5871 Email:harkenconstruction@gmaii.com +Fr.+ + %> �+� „' 1fb ' ':'� t�.�. 1 A''•• tEf 1 �— qy r� '*?,. e s yrr 4 S3 ,��+�4{ 9! �� k i �I �, DESIGN PROFES$IQNAL INFORMATION } ' .a a ,.^� ,�' ,4:, <, r: v t. :.€r>rh �p•^�{,,�r,,. ]n .. Name:James Deerkoski, PE Mailing Address:260 Deer Drive, Mattituck, NY 11952 Phone#:631-298-5506 Email: F z.. ' Name:Harken Construction Mailing Address:110 Eastside Ave., Mattituck, NY 11952 Phone#:516-971-5871 Email:harkenconstruction@gmail.com � . DESCRIPTION,OF PROPOSEDtCONSTRUUL- 10, 3^r.'✓'��.? ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: EEOtherin-ground swimming pool $75,000 Will the lot be re-graded? ❑Yes R No Will excess fill be removed from premises? ❑Yes R No 1 . r r M r �rti PROPERTY°INFOR ATION '�� u Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to _......_.a. ._w _.._ ._ this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑!Check BAX After Reading The owner�antfactor/desigp professional Is responsible for all drainage and stoft water Issues as provided by. Chapter 2*0 of;the fowrt Cade �APPLICATiON ISA HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone, Ordinance of the Town of Southold,Suffolk,County,NewlYork and other applicable Laws,Ordinances or Regulations,for the construction of buildings,A;` additions,alterationsor for removal or demolition as hereindescribel The applicant agrees to comply with all applicable laws,ordinances,building code, housing code,and regufatfons and to admit authorlied Inspectors on premises and in bullding(s)�for necessary inspections False statements made herein are ` punishable as'a Class A misdemeanor pursuant to Section 210 45 of 1 he NewIj ;York,State'PenaF Lauv Application Submitted By(print name): �� �-(-'z- ��❑Authorrized Agent ❑Owner Signature of Applicant: _ _ ___ ~ ___ Date: /Z�A �2,Y Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 SS: Qualified In Suffolk County COU NTY O F ) commission Expires April 14,2 S(aq Charles Kitz being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, Owner (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this A _ �-'"�n 1 n day of R4 CA . 20 r--f Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 D E C E U LS BUILDING DEPARTMENT- Electrical ector TOWN OF SOUTHOLD MAR 1 ► 2025 Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Building Department ® o�/ry Telephone (631) 765-1802 - FAX (631) 7657-`Mf Southold '�O,j � �fir,• jamesh(D-southoldtownny.gov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: 0. E ( C �� Electrician's Name: °J� A �P� License No.: M k 3GS 3 3 Elec. email: e,40 e-Weel ,46u ,Corn Elec. Phone No: f- Ja-z�g�- ❑I request an email copy of Certificate of Compliance Elec. Address.: � k/ht S ' &Ao Mas4,'c t3r*c4 JOB SITE INFORMATION (All Information Required) Name: 5j1L24,-`CN d t- ae Address: ( Je 4+ Cross Street: Phone No.: Bldg.Permit#: 51)6 4o email: Tax Map District: 1000 Section: Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 R2 H Frame Pole Work done on Service? Y RN Additional Information: PAYMENT DUE WITH APPLICATION / D E C E U E �S�fFO(,�� BUILDING DEPARTMENT- Electrical ector TOWN OF SOUTHOLD MAR 12025 Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Building Department oy • � Y f Southold 1j19! Sao Jti Telephone (631) 765-1802 - FAX (631) 765T` � ' � jamesh(�southoldtownny.gov - sea nd(aD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: �: a ( e -Z� Electrician's Name: '�� =-A °efi' License No.: Iv)k -3GS3 Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: 1 tuht S . al) MA.5-4,'c JOB SITE INFORMATION (All Information Required) Name: 5v1L24-`C,N Address: Cross Street: Phone No.: Bldg.Permit#: 0640 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): W] 1,N y ANC qro�I,-A,',v y 6w11'MM,,, y jai Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground[]Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATION l / 3 ``,a� PERMIT# Address: Switches (~ Outlets GFI's I l l Surface Sconces H H's UC Lts Fridge HW POOL Panel ,�� 12 -6 \ Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr �GC3 Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bon f �� Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH =. Hood Blower Service Amps Have Used Sub Amps Have Used Comments Scott A. Russell � 0sUFFQt 5T01KMWAiT1E1K SUPERVISOR M[ANA\(G IEMLENT S5 Main R D TOWN HALL ,NEWBox K. Town of So u th o l d 53695 Main Road-SO(1'I'HOLD,NEW YORK. 11971 CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: ( Date: IP'in 1 � S (sign, Contact Information: ��'_ r� a� J (E Mail&Telephone Numher) /r r Property Address / Location of Construction Site: L�—?,q& k2F yrt j—r�i rV14 S.C.T.M. #: 1000 DisU-Ict i ' �� Section Block Lot TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Area of Disturbance is less than I Acre. -No S.P.D.E.S. Permit is Required! - Project does Not Discharge to Waters of the State. No S.P.D.E.S. Permit is Required ! �I - Area of Disturbance is Greater than I Adre & Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit DIRECTLY From N.Y.S. D.E.C. Prior to Issuance of a Building Permit. i Area of Disturbance is Greater than I Acre& Storm-water Runoff Flows Through Southold i ❑ Towns MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town Engineering Department Prior to Issuance of a Building Permit. _SJ­7 J Reviewed By; ��l`i� '" Date: �1 FCIR M 4 WCP-TC1C of-tnhPr 7n i q �f / N/0/F GE OLMAN TEST HOLE DATA BUD GEOR ANT 1 (TEST HOLE DUG BY NATHAN CORWIN L.S. ON APRIL 27, 2021) VACAN 3 Q Q • Q O EL. 17.0' 0' TOPSOIL & LOAM OL Drainage Calculations 10019 �0 1' g Q 3 � E N v �o � (�House-Main Rear Roof BROWN SAND SM \� 46'-8"x 28'-4"=1,2121.9 sf \S House-Main Front Roof O 0 46'-8"x 13'-4"=622.2 sf Z Q House-Rear Entry Roof J FINE TO SAND SP J 16'x9'=144sf O 0. O J House-Side Porch Roof 15'x 22'-4"=335 sf Q0 1 HIGHEST EXPECTED GROUND WATER EL. 5.4' 11.6' House-Front Porch Roof O \s TEST WELL No. USGS 405856072324001 S 1 5004.1 8'-6"x 30'-8"=260.7 sf (D \R EL. 2.3' 14.7' OBSERVED GROUNDWATER WATER IN Garage \� FINE TO SAND SP 22'-8"x 24'-8"=559.11 sf O ' Drainage Pool#1 W 0 0 D E D O House-Main Rear Roof 1,321.93 sf House-Rear Entry Roof -144 s>f Garage -599.111 sf ti' n'�:, Total 2,665.0)1 sf " Z >� 2"Rainfall=2=0.1666 cf/sf NeW Pool F , Drainage Volume(Requirement=2,60)64.98 x 0.1666=344.03 cf New Drainage Capacity for 8"Diameter Drainage Pool= Interior Diameter 8'-8"=7.33' j One b Radius=7.33'/2:=3.66' \� Story x Volume per Foot==Tr x 3.66 2=42.1 c:f/ft \, Gorog Required Depth=344.03/42.1 = 8.117 ft Use a 10'Deep 8'93 Drainage Pool Drainage Pool#2 House-Main Front Roof -622.2 sif House-Side Porch Roof -335 sf House-Front Porch Roof -260 sf 0 0 a New Total 1,217.2 sfi bJ Two Story rai ge Pool# � Home 2"Rainfall=12=0.1666 cf/sf b ❑ ❑ Drainage Volume Requirement= 1,2117.2 x 0.1666=202.8 cf q'i _ Drainage Capacity,for 8"Diameter Drainage Pool= Interior Diameter 8'-8"=7.33' to Radius=7.33'/2=3.66' O O Volume per Foot 7T x 3.66 2=42.1 rf/ft Required Depth=202.8/42.1 =4.8 fir O �' Use a 8'Deep 8'0 Drainage Pool Z{ n e Pool#2 82'-4 a �O 'K \o .� N Suffolk County Standard Drain Manhole frame TCID W and slotted cover Pattern No. 1383 or manhole t .� 500.00' cover Pattern No. 1012A-TYPE C a Notes: (JI = manufactured by Cambell Foundry or an SE[) W TER approved equal. 1. Steel reinforcing on leaching sections P welded wire fabric 6"x12" #6x#8. W TEST HOLE SURVEY OF PROPERTY O _ 117.0 30\0 - 00 Min. 2 Brick Course 2. 8" thick traffic bearing cover ' -SPUT RAIL FENCE SITUATE O w � �� W NJew Gravel Driveway" 7�_5 MATTITUCK. S 8531 pQ w w 1� TOWN OF SOUTHOLD „ , IL#5 POLE w �,. SUFFOLK COUNTY, NEW YORK LIL#5 8 Traffic Bt„aring Cover finished Grade 16.6 w w � PUBLIC WATER IN STREET EDGE OF PAVEMENT G � w w \� ������ S.0 TAX No. 1000-123-01 -06 6" SDR-35 Drainage Pipe, w i� s SCALE 1°=20' �� AI�,K AVENUEP Q�oQo APRIL 27 2021 DWELLING DWELLINGUSES PUBLIC WATER Surveyed By : Precast USES PUBLIC WATER Nathan Taft Corwin III rainag -o DWELLING Rings m t03 - r USES PUBLIC WATER C-) z Wrap with 6 oz. (min.) DWELLING �► �P�EOF ✓NE y nonwoven eotextile filter g ( USES PUBLIC WATER `� 'o�,� °0�00 fabric) Mirafi 140N or an approved equal - = ' 81 Leaching Basin Notes: 4. No trench, pit or other excavation shall be I left open or unattended. Excavations to be protected as Plans are prepared by Condon Engineering,P.C. it is a violation of the New Yak States Education directed by the Engineer with fences, barricades and other approved methods. Law,Article 145,Section 7209,for any person unless acting under the direction of kmnsed FO 684 Professional Engineer,Architect,or Land Surveyor,to after any item in any way.If an iteem bearing 1. Leaching Pools shall be Precast Concrete Cement structures as the seat of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Aarchitect,or S10NP Manufactured by Suffolk Precast Inc. or equivalent. 5. Invert elevations may be adjusted by the[Engineer in the field to meet field conditions to avoid Land Surveyor shall affix to the item hislher seal and the notation*Altered by foltowed by hmw conflict with utilities as ordered by the Engineer. signature and the date of such alterations,and a specific description of fhe alteration. Elevation View 2.All concrete cement used in the manufacturing of precast structures shall 6. Allow four(4) inches for final adjusting of(casting. adequate bearing will be provided using develop a minimum compressive strength of 4,000 p.s.i. in 28 days. concrete block, buck and/or 1:2 mortar mix. Scale: 1/4" - 1'-0' Excavate and backfill 3 feet - Condon Engineering, P.C. r� DWell DetaiI 3.All draina a structures shall be laced in acce table leachin Soils as 7. The contractor shall provide adequate sheteting and shoring during trenching to insure the safetyaround and below leaching ringsg p p g of workmen and the general public exposed to thie hazards of falling and sliding material in conformance Drawn by : JJC 6L,� Park Ave n U e with suitable porous material as approved by the Engineer. In the event poor leaching maternal is with the requirements of the Title 29 Code of Fedieral Regulations, Part 1926,Safety and Health 1755 Sigsbee Road Alla�tltuck, New York approved by the Engineer. back filled as excavation is to be continued to suitable material and Regulations for Construction(OSHA). Mattituck, New York 11952 Date : 2-27-2024 backfilled as detailed. (631) 298-1986 8. Backftll and compaction shall be in 6"lifts. SLK TION COMPLIES WITH: LIGHT BENCH 2020 CODE SECTION 303.2.1-303.4 SWIMMING POOLS, SPAS, FILTER AND HOT TUBS SECTION R326 OF THE RESIDENTIAL CODE OF NEW YORK PUMP SECTION 3109 OF THE BUILDING CODE OF NEW YORK SECTION N1103.12 (R403.12) RESIDENTIAL POOLS AND PERMANENT RESIDENTIAL SPAS ` r A TO SECTION 3109.3.1.2 - 3109.7.4 POOLS AND SPA GATES, COVER BARRIERS SECTION G106 ENTRAPMENT PROTECTION SECTION G107 ALARMS SECTION E4201 E4312 ELECTRICAL CONNECTIONS FOR GUNITE 4' 8' PR V D AeWED DAN,;. S 8 B.P.*FEE 561� INOTI ILDING DEPARTMENTAT COPING) (PAVERS) 631- 1802 BAM TO 4PM FOR THE MORTAR ` FOLL ING INSPECTIONS: RETURN s"TILE 1. FO NDATION-TWO REQUIRED � �_a a •' FO POURED CONCRETE ,ao, 2. RC GH-FRAMING&PLUMBING MARBLE DUST e •' ' 40' 3. II0 LATION 13 & 94 STEEL REBAR NER POOL PLAN - 4. FI -CONSTRUCTION MUST 12"OC I XCE'OC FOR GEPTH EXCEEDING 5 FEE a � BE OMPLETE FOR C.O. GRADEILL TO AROUND 93 & 84 STEEL RE GRADE 5' AROUND ALL C STRUCTION SHALL MEET THE (ECRIZCTViAL POOL PERIMETER REQUI MENTS OF THE CODES OF NEW 12" ' 'a YORK TATE. NOT RESPONSIBLE FOR ' DESIG NAIE OR CONSTRUCTON ERRORS 12"TO RIE36"I •!� SI 3500 psi A _ CONCRETE • C B" (MIN.) ' .•' O.i•0 ' ! O at WALE SECTION N.T.S. 19, 6" 12' 8' 6" OF E ATELY-�;;�- SWIMING POOL. TO BE EXCAVATED ONE FOOT OVER DESIGN SPECIFICATIONS AND COMPLY WITH ALL CODES El`;CLOSE P L T4;'CQ.b SOIL TO BE LEFT ON PROPERTY, SOIL TO BE STOCKPILED OR RUFF GRADED (AS NEW YORK STATE&TOWN CODES llPON'CO PLETIN., PER OWNER( ON THE DAY OF EXCAVATION ONLY UNLESS SOIL IS TO BE CARTED AS REQUIRED AND CONDI NS OF j � , AWAY" WAT ` . z: ' SWIMING POOL STRUCTURE TO INCLUDE A MATT OF 3/8" STEEL REBAR TIED, SMMLDTO ZBA POOL SECTION VIEW 12" ON CENTER FOR WALLS AND FLOOR, 5" ON CENTER FOR ALL TRANSITION { OWN PIANNING BOARD BREAKS AND BOND BEAM. THE POOL SHELL TO BE MADE OF 1-4 DRY GROUT GUNITE MIX SHOT INTO THE TOWN TRUSTEES F F NEIV STEEL CAGE AT A THICKNESS OF NO LESS THAN 12" ON THE TOP EDGE OF THE N. , ,DEC g y pEEiQ y0 POOL (BOND BEAM) AND NO LESS THAN 8" ON THE WALLS AND FLOOR, ` 4 V 1i.r '1 INTERIOR FINISH OF POOL TO BE "PEBBLE TECH" DURABLE FINISH, COLORS AS OLD K�i .* 'T „ �0 � PICO POOLS �^�' 8� �� ®� PER OWNER, dy u SCHD � _� " � z w JSE IS U LAWFUL N� ;STAIN STORM WATER RUNOFF ELECTRICAL °A °� POOL TYPEdBX4D RECTMfLE REV. N.T.S. NITHOU CEPTIFICA i PURSUANT TO CHAPTER 236 INSPECTION REQUIRED �OFES&ONP�' MAT PARK AVE. DATE 3i1424 MAT PARK NY CRAWING NUMBER '.)F OCC PANCY OF THE TOWN CODE. I OF 2 NOTES: 1. CONFORM WITH ANSI/APSP/ICC-5 SEC 6 2. NO SOIL DISCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION 3. POOL/SPA MUST BE SURROUNDED BY A CONTINUOUS BARRIER CONSTRUCTED IAW REQ.OF SEC 326.4.2.1-R326.4.2.6 OF THE NYS RESIDENTIAL CODE(2020)AND ALL SECTIONS OF THE SOUTHOLD CODE 4. WALLS MAY SERVE AS PART OF THE POOL/SPA BARRIER AS PER SEC 326.4.2.8 AND ALL WINDOWS HAVE A SELF LATCHING DEVICE 5. ACESS GATES SHALL COMPLY WITH SEC R326.5.2 OF THE NYS RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY LOCKED WHEN POOUSPA IS NOT IN USE OR SUPERVISED. ALLL GATES ARE TO OPEN AWAY FROM THE SPA AREA. 6. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION IAW CODE OF THE TOWN OF SOUTHOLD. 7. POOUSPA MUST BE EQUIPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND SOUNDING AN AUDIBLE ALARM WHEN DETECTED THAT IS AUDIBLE AT THE POOUSPA SIDE AND INSIDE THE DWELLING.THE ALARM MUST BE INSTALLED,MAINTAINED AND USED IN ACCORDANCE WITH TEH MAUFACTURERS INSTRUCTIONS.THE ALARM MUST MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL ALARMS". THE DEVICE MUST OPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS. 8. POOUSPA SUCTION FITTINGS(EXCEPT FOR SURFACE SKIIMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASME/ANSI Al 12.19.8M OR A MINIMUM 18"X23"DRAIN GRATE OR A CHANNEL DRAIN SYSTEM.POOUSPA CIRCULATION SYSTEM MUST BE EQUIPTED WITH ATMOSPHERIC VACUUM RELEIF.SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME Al12.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD. POOUSPA SHALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF T AND MUST BE PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS).VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN ACCESSIBLE POSITION,MINIMUM OF 6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMER/SKIMMERS. A REQUIRED SPA ATMOSPHERIC VACUUM RELEIF SYSTEM SHALL BE INSTALLED AS PER NYS RESIDENTIAL CODE R326.6.3(2020)AND IN ACCORDANCE TO TOWN CODE 9. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC),PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL CODE SECTION 4102 THROUGH 4106.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GOUND FAULT CURRENT INTERRUPER(GFCI).CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER TO POOUSPA LIGHTING AND SPA EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4203.5. ALL METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENT TO THE POOUSPA THAT MAY BECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED. 10. WATER SOURCE FILLING THE POOUSPA SHALL BE EQUIPPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS PLUMBING CODE 608. _ 11. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. _ 12. WALKS,IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM THE POOL/SPA EDGE. 13. A MEANS OF EGRESS FROM THE POOUSPA MUST BE PROVIDED IAW ANSI/NSPI-5 SECTION 6. 14. CONTRACTOR TO PLACE THE POOUSPA IAW TOWN OF SOUTHOLD CODE SETBACKS. 15. ALL DRAINAGE FROM THE POOUSPA SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. 16 THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION.IF GROUND WATER EXISTS WITHIN 60"FROM GRADE, DEWATERING FACILITIES WILL BE REQUIRED. 17 ALL GAS AND OIL WATER HEATERS(IF INSTALLED)FOR THE IN-GROUND POOUSPA SHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT.POOUSPA HEATERS SHALL BE TESTED IAW ANSI Z21.56 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS.OIL FIRED POOUSPA HEATERS SHALL BE TESTED IAW UL726.POOUSPA HEATERS SHALL BE LOCATED OR GUARDED TO PROTECT AGAINST ACCIDENTAL CONTACT OF HOT SURFACES BY PERSONS.POOUSPA HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES.A BYPASS LINE SHALL BE INSTALLED FROM THE INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HATER.POOUSPA HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES: 17.1 ALL POOUSPA HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. AT LEAST ONE THERMOSTAL MUST BE PROVIDED FOR EACH HEATING SYSTEM.HEATED POOUSPAS SHALL BE EQUIPTED WITH A POOUSPA COVER.(EXEMPT FROM THIS ARE OUTDOOR POOLS)DERIVING 20%OF THE ENERGY FOR HEATING THE POOUSPA FROM RENEWABLE SOURCES OVER AN OPERATING SEASON. 17.2 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SET TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS,AND CAN BE SET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOUSPA WATER IN A CLEAN AND SANITORY CONDITION IAW APPLCIABLE SANITORY CODE OF NEW YORK STATE. 18 BACKFILL WILL BE DONE WITH CLEAN EARTH FREE OF ROOTS AND DEBRIS. BACKFILL HEIGHT AND WATER LEVEL TO BE WITHIN 8"OF EACH OTHER. PLACE CONCRETE ON SANDY LOAM SOIL. CLAY TO BE REMOVED AND REPLACED WITH SANDY LOAM. 19 THERE IS NO MAIN DRAIN IN THIS POOL/SPA. SUCTION FOR THE POOL SPA WATER CICULATION IS PROVIDED BY THE SKIMMERS ONLY. THIS MEETS REQUIREMENTS OF NYS CODE SEC 326.5 FOR ENTRAPMENT PROTECTION 20 THE POOUSPA WAS DESIGNED REFERENCES AS THE FOLLOWING: Pico Pools 20.1 THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE(2020)SEC R326 O E Y 20.2 THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2020)SEC R403.10 Q p O 625 Park Ave. � r•., 20.3 THE FUEL GAS CODE OF NEW YORK STATE(2020) * �/ Os Mattituck, NY 20.4 THE NEW YORK STATE SANITORY CODE. 20.5 ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS AND SPAS. Z _ :� Z POOL/SPA NOTES SCALE: NTS 20.6 BOCA CODE SECTION 421. �� �� , P.E. pA 0775 2. JAMES DEERKOSKI DATE: 311412024 20.7 CODE OF THE TOWN OF SOUTHOLD ROFIFSSIDNP� 260 DEER DRIVE MATTITUK, NEW YORK 11952 DRAWING NUMBER 2 OF 2