Loading...
HomeMy WebLinkAbout52118-Z of so�ryolo Town of Southold * * P.O. Box 1179 �0 53095 Main Rd ��rcoUNv.N`� Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46641 Date: 10/29/2025 THIS CERTIFIES that the building EV CHARGER Location of Property: 4715 Great Peconic Bay Blvd Laurel, NY 11948 Sec/Block/Lot: 125.4-24.23 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 05/27/2025 Pursuant to which Building Permit No. 52118 and dated: 07/21/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: 4 electric vehicle charging stations as applied for. The certificate is issued to: Laurel Links Cntry Club Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 25-104682 10/16/2025 PLUMBERS CERTIFICATION: A hori ed S' a e �o�aofsaveyo� TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52118 Date: 07/21/2025 Permission is hereby granted to: Laurel Links Cntry Club PO BOX 307 Laurel, NY 11948 To: Install 4 electric vehicle charging stations and the required equipment to include conduits,electric wiring, meter/panel, bollards and signage as applied for per manufacturers specification and installation.Additional certification may be required. Premises Located at: 4715 Great Peconic Bay Blvd, Laurel, NY 11948 SCTM# 125.-4-24.23 Pursuant to application dated 05/27/2025 and approved by the Building Inspector. To expire on 07/21/2027. Contractors: Required Inspections: Fees: EV Charger $500.00 Electrical-Commercial $400.00 CO Commercial $400.00 Total $1,300.00 Building Inspector Certificate of Compliance ................................................................................................................................................................................................... ....... ..... 7, 1 CERTIFIED ELECTRICAL INSPECTIONS, I ' f 188 PARK AVENUE 2 �� 2025 AMITYVILLE, NY 11701 ............................................................................P: (631) 598-5610. ............................................................BuF'�tizr� CERTIFIES THAT �CW""' of Upon the application of Upon premises owned by Woodhollow Contracting Corp. Laurel Links Country Club 103 School Street 4715 Great Peconic Bay Blvd Lindenhurst, NY 11757 Laurel, NY 11948 Located at: 4715 Great Peconic Bay Blvd, Laurel, NY 11948 Application Number#: 25-104682 Certificate#: 25-104682 Electrical License#: ME-60139 Section: 125 Block: 4 Lot: 24.23 Building Permit#: 52118 Described as a Commercial Building occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: EV Chargers (4) A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the 16th day of October 2025 Name QTY EV Charging Station - 60 Amp, 240V 4 Meter-400 Amp, 240V 1 Service Disconnect- 300 Amp, 240V 1 Circuit Breaker- 60 Amp, 240V 8 Electrical Inspector: Sal Frangipane `AAPl'RS`1v �ti, f - r", _ 1•� - OF SOUlyolo # # TOWN OF SOUTHOLD BUILDING DEPT. °o0um, 631-765-1802 �- NS-PECTION [ OUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [. ] FIREPLACE & CHIMNEY [ ] .FIRE SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION A ] PRE C/O : [ ] REN AL REMARKS: V v K/y r DATE '3Q INSPECTO pF SOUTyolo f # TOWN OF SOUTHOLD BUILDING DEPT. °ycoum, 631-765-1802 INSPECTION 'y< <�d [ ] FOUNDATION 1ST,/ REBAR [ . ] ROUGH PLBG. [ . ] FOUNDATION 2ND [ . ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 'j eV CW646, [ :] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION . [ ] --FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O - [ ] RENTAL REMARKS: tc DATE 0 INSPECTOR TOWN OF SOUTHOLD—BUILDING DEPARTMENT y x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT {� r' L Z nV Ip� For Office Use Only f n r PERMIT NO. I Building Inspector: t 77,7,7 Applications and forms must b In their entirety,Incomplete h .4 r s N 3 E 1 a'`appllcatlons wili'pot be accepted Where the Applicant is not'the Owner s Author�xaon form(Page 2)shall becampletey Date:May 19th 2025 OWNERS)OF PROPERTIt� Name:Laurel Links Country Club Incorperatedl SCTM#1000-125-4-24 23 Project Address:4715 Great Peconic Bay Blvd, Laurel NY 11948 aka 6400 Main Rd, Mattituck NY Phone#:631- 298 - 4352 Email:JLanders laurellinkscc.com Mailing Address: MAIN RD, MATTITUCK NY 11948 - . _ �t . - -�___ , . t Name:Jim Landers Mailing Address:6400 MAIN RD, MATTITUCK NY 11948 Phone#:631- 298 - 4352 Email:JLanders laurellinkscc.com 'DESIGN PROFESSIONA) INFORMi,T10N �. Name:Woodhollow Designs Mailing Address:103 School St, Lindenhurst NY 11757 Phone#:5168275916 Email:permits@woodhollowdesigns.com NTRACTOR.,I.,wNFORNATIOIVeR�� .: � ,' i .0 a i t iI h Name:Woodhollow Contracting Corp Mailing Address:103 School St, Lindenhurst NY 11757 Phone#:516-827-5916 Email:permits@woodhollowdesignscom * DEscRIPTION ofRoaosD co�lsTRucTloly3 +�b „ . . . ..w. �rv. . ._....,z .._. __�.... :... ....� �_ i _d ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: EEOther Electric Vechile Chargers $45000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ONo 1 _.:-. ..:: PROPERTY INF:...ORMATION lit Existing.use of property. C j Jam . G` I Intended use of property Zone or use district in;which:premises is situated ' Are there any covenants and restrictions with respect to I ;this property? ❑Yes:ONo IF YES,PROVIDE A COPY. .: Uff,Check BOX After Reading Thep professional is responsible forall drainage and storm water issues as provided by Chapter;236 of the Town Code APPLICATION IS HEREBY MADE to the:Building Department torthe Issuance of a IBuliding Permit pursuant to the Building Zone Ordinance of the Town of Southold;Suffolk County,New York and,otlier applicable Laws,Ordinances or Regulations,for the construction of 6ulldtngs, additions alterations or foc:_removal ordemolition as herein described.The applicant agrees to comply with all'applicable taws,ordinances,buliding vide; -. housing code and reguiatlons and to admit authorized Inspectors on premises and in building(s)for necessary inspections:.False statements made Fiereln:are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.. . '' Application'Submitted By /in ame):1Vv�dh0��0� ��H�j uthorized Agent ❑Owner Signature of Applicant: ��'- Dater t 4 12� STATE OF:NEW'YORK) SS: COUNTY OF :jj: rl\C�6w being duly sworn,deposes and saysthat(s)he is:tlie applicant (Name of Individual signing contract)above named, } ( s he .... (Contractor,Agent,Corporate Officer,etc.) of said:owner or owners,and'.is duly authorized to perform or have performed the said work and to make and file this application;that all statement's contained in this:application are true to the best of his/her know age:dRu. 9 T APELER that the work will be performed in the manner set forth in the application file therewith: Notary Public-State of w York NO.Of AP6423078 Qualified in Nassau Cd rty Sworn before me this / My Co m tssion Expires Oct4,2025 l -v .:da of Notary P li Y SZOZ'b po sajldx3 uolsslwwo,Aw PROPERTY O:WNER;AUTHORIZATION ; lgtJno�nesseN ul paL�llenb BLOEZf'9dV10'ON ` (Wher`e the applicant IS nOt i' oWn`er)' �JOA MaN;o a3e+S �i►a�z tielo� )J313dV VNIlSQJHD f residin..:..:: at,_. _u . g 1 _do herebyauthorize ` to apply on my behalf,' the Town of Southold Building Department for approval:as,described herein.. pw 'er's SignatureDate. Qt�e� 6-ry rrr Print[0wnei's Name 2 C n O INTERNAL USE ONLY JUN 3 0 ZO25 1 SITE PLALC 01E DETERMINATION SOUTHOLD TOWN PLANNING S6ARD -J U L 1 6 '2025 Initial Determina i n Date:U_� /oJu44a�in�DepartmentDate Sent: T vn o soutl I� Club cr�r�ora-�ecl Project Name: �arP LI nSUl�rl1� \! Project Address: ) 'I {G Cl LV •' �, L"fo0 NI>J d cl°l1Uck p _�__ y f a Zoning District: AC-/ 40 Suffolk County Tax Ma NoL:�100_01- 5 - Ig,, Request: -I'1GZ.�I v (Note: Copy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) `J Initial Determination as to whether use is permitted:-e�i Initial Determination as to whether site plan is required: \ Signature f Building Inspe o Planning Department (P.D.) Referral: J / P.D. Date Received: Date of Comment: jommen c Yiv �t�` i�C ttr�S2 lS e E Signature of Planning Dept. Sta viewer Final Determination Date:—J—� Decision: Signature of Building Inspector �oSOFfat/ BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 Southold New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/25/2025 Company Name: WOODHOLLOW CONTRACTING CORP Electrician's Name: NICHOLAS GASPARO License No.: ME-60139 Elec. email: permits@woodhollowdesigns.com Elec. Phone No: 516-827-5916 ❑I request an email copy of Certificate of Compliance Elec. Address.: 103 SCHOOL ST, LINDENHURST NY 11757 JOB SITE INFORMATION (All Information Required) `J Name: Laurel Links Country Club Incorporated V Address: 4715 Great Peconic Bay Blvd, Laurel NY 11948 aka 6400 Main Rd, Mattituck NY Cross Street: Phone No.: 631- 298 -4352 Bldg.Permit#: email: permits@woodhollowdesigns.com Tax Map District: 1000 Section:,M 13,5 Block: 4 Lot: 24.23 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 2 electric vehicle chargers:Install:Underground 120/208v 200-amp 3 phase service from utility pole to servcie areal 400-amp 3-phase meter, 200 amp main breaker panel, (2)100 amp dedicated circuts for 2 dual pedestals,2 footings,4 bollards w/concrete footings, 4 ev parking signs on struts w/footings, restoration &trenching Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES FV-� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals M 1 2171 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ��S�fFOlk�o BUILDING DEPARTMENT- Electrical Inspector 0�0 Oye TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/25/2025 Company Name: WOODHOLLOW CONTRACTING CORP Electrician's Name: NICHOLAS GASPARO License No.: ME-60139 Elec. email: permits@woodhollowdesigns.com Elec. Phone No: 516-827-5916 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 103 SCHOOL ST, LINDENHURST NY 11757 JOB SITE INFORMATION (All Information Required) Name: Laurel Links Country Club Incorporated V l� Address: 4715 Great Peconic Bay Blvd, Laurel NY 11948 aka 6400 Main Rd, Mattituck NY Cross Street: Phone No.: 631- 298 -4352 Bldg.Permit#: email: permits@woodhollowdesigns.com Tax Map District: 1000 Section: /a5 Block: 4 Lot: 24.23 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 2 electric vehicle chargers:Install:Underground 120/208v 200-amp 3 phase service from utility pole to servcie area,l 400-amp 3-phase meter, 200 amp main breaker panel, (2)100 amp dedicated circuts for 2 dual pedestals,2 footings,4 bollards w/concrete footings, 4 ev parking signs on struts w/footings, restoration &trenching Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES FV�, NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �gllFfQtkG' BUILDING DEPARTMENT- Electrical Inspector �dGy TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/25/2025 Company Name: WOODHOLLOW CONTRACTING CORP Electrician's Name: NICHOLAS GASPARO License No.: ME-60139 Elec. email: permits@woodhollowdesigns.com Elec. Phone No: 516-827-5916 ❑I request an email copy of Certificate of Compliance Elec. Address.: 103 SCHOOL ST, LINDENHURST NY 11757 JOB SITE INFORMATION (All Information Required) Evc._ Name: Laurel Links Country Club Incorporated Address: 4715 Great Peconic Bay Blvd, Laurel NY 11948 aka 6400 Main Rd, Mattituck NY Cross Street: Phone No.: 631-298 -4352 Bldg.Permit#: email: Permits@woodhollowdesigns.com Tax Map District: 1000 Section:-W /a'5 Block: 4 Lot: 24.23 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 2 electric vehicle chargers:Install:Underground 120/208v 200-amp 3 phase service from utility pole to servcie areal 400-amp 3-phase meter, 200 amp main breaker panel,(2)100 amp dedicated,circuts for 2 dual pedestals,2 footings,4 bollards w/concrete footings, 4 ev parking signs on struts w/footings, restoration &trenching Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES FV—]NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals M 1 2 H Frame M Pole Work done on Service? El Y N Additional Information: PAYMENT DUE WITH APPLICATION lQg�FfUL�CO BUILDING DEPARTMENT- Electrical Inspector �O l� TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/25/2025 Company Name: WOODHOLLOW CONTRACTING CORP Electrician's Name: NICHOLAS GASPARO License No.: ME-60139 Elec. email: permits@woodhollowdesigns.com Elec. Phone No: 516-827-5916 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 103 SCHOOL ST, LINDENHURST NY 11757 JOB SITE INFORMATION (All Information Required) �/(' _ Name: Laurel Links Country Club Incorporated [--V v Address: 4715 Great Peconic Bay Blvd, Laurel NY 11948 aka 6400 Main Rd, Mattituck NY Cross Street: Phone No.: 631- 298 -4352 Bldg.Permit#: email: permits@woodhollowdesigns.com Tax Map District: 1000 Section: 101 Block: 4 Lot: 24.23 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 2 electric vehicle chargers:Install:Underground 120/208v 200-amp 3 phase service from utility pole to servcie areal 400-amp 3-phase meter, 200 amp main breaker panel,(2)100 amp dedicated circuts for 2 dual pedestals,2 footings,4 bollards w/concrete footings, 4 ev parking signs on struts w/footings, restoration &trenching Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 R H Frame Pole Work done on Service? Y F7 IN Additional Information: PAYMENT DUE WITH APPLICATION I CLIENT, PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA 6400 MAIN RD MATTITUCK, NY 11952 Model Nlumber Connector Type Dimensions (H*' *D) Max! US AC W 12-L-4 G SAE J 17 7 2 1 3er x 7 ft rr 3 3 5 x 187 x 85 m m) DESIGN CONSULTANT- Weight Input cord Warranty 14.8 Ihs. (5.7 kg) Hardw[red only 3 years Charging Oahe Length Connectivity User authentication CONTRACTOR or VENDOR: 25 ft. (7. m) 4 G, Bluetoeth, W -Fi, Ethernet, PS4 R 5 App, AutoSta rt, IMF I D card j l WoodoRow Advanced Feature Output Rating Input Rating Adaptive Lead Mianagement (ALM); Dynamic Load Balancing (DLB) Maximum 12 kW (240 \IA.0 @ 50 A model) 208/240 VACR 00 Hz single phase 10 A, 24 A, 32 Ar 401 A� 48 A, 50 103 School St, Lindenhurst, NY 11757 A LEGAL NOTES_ "It is a violation of the state education law for any person, Protection �+ } Temperature unless he or she is acting under the direction of a f rp�,tection Operating ng 1 emperatu a Mounting licensed professional engineer to alter an item in wy. If �.P �U 1�� on this drawing and/or in this specification in anyway. If any such item is altered, the altering engineer shall affix to OVercurrent, overvoltagef undervoltage, integrated surge protection -40 to 131 OF (•-40 to 55 OC) Wall-mounted or floor using a pedestal the item his or her r signature and the notation 'altered such followed by his or her si nature and the dote of such alteration, and a specific description of the alteration." • Any errors and omissions in the drawing are to be checked by the general contractor and relayed to the arch itect/EOR • Do not scale drawings • All work shall comply with the local building code(s) 01-12.611 I � �_ 01-4.311 and with requirements of local AHJ I I KEY PLAN: _I 01_711 01_311 AUTEL i I 1 0 0 0 0 0 2.0 05.14.25 COMPLETE DESIGN 1 .0 04.17.25 INITIAL DESIGN LAYOUT 01-107.211 01-10411 REV DATE DESCRIPTION I 01-3711 I� 1UU �j I PROJECT NAME ELECTRIC VEHICLE CHARGING STATION INSTALLATION AT I 6400 MAIN RD MATTITUCK, NY 11952 AKA 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 I I - - SHEET TITLE � �- 01-7.911 EV CHARGER DETAIL SEAL PROJECT NO:LAUREL LINKS AUTEL CABLE AUTEL SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH MANAGER PEDESTAL CHECKS B i Rood APPROVED AS NOTED `7-a I-a5 B.P# COMPLY WITH ALL CODES OF DATE' NEW YORK STATE&TOWN CODES E F a00'( BY-y _ S REQUIRED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT S0UM0LDT0VWZM 631-765-1802 8AM TO 4PM FOR THE t0U HOLD T0VN PLAMVIN'G BOARD FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED .y& OLDTO',Vt�TROST N FOR POURED CONCRETE Y,S.DEC ROUGH-FRAMING&PLUMBING SIMIOLDHPC INSULATION SCHD FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS Additional Certification May Be Required. • New York State Law You Must Call 811 Before You Dig I CLIENT, PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA 6400 MAIN RD MATTITUCK, NY 11952 DESIGN CONSULTANT: INSTALLATION OF ELECTRIC VEHICLE CHARGING EQUIPMENT oil D 'I �,> 6400 MAIN R MATTITUCK , NY 11592 AsKmA CONTRACTOR or VENDOR: 4715 GREAT PECONIC BAY BLVD LAUREL NY 11948 Woodhollow �'C^/l�/"II�lN1CJ' t•1L•/�. 103 School St, PROJECT DESCRIPTION Lindenhurst, NY 11757 w ABBREVIATIONS INSTALL CONDUITS AND ELECTRICAL WIRING LEGAL NOTES: �rP mom. A AMPERE It is a violation of the state education law for any person, unless he or she is acting under the direction of a INSTALL NEW DISPENSERS CKT CIRCUIT licensed professional engineer to alter an item in anyway, z � gr on this drawing and/or in this specification in anyway. If any such item is altered, the altering engineer shall affix to MOVCU COPPER the item his or her seal and the notation "altered by" followed by his or her signature and the date of such t alteration, and a specific description of the alteration." � # ..n,. SHEET EQUIPMENT p p SHEET NAME { NUMBER . Any errors and omissions in the drawing are to be EG C GROUND checked by the general contractor and relayed to the � E-100 COVER SHEET arahitect�EOR CONDUCTOR oa not scale drawings 9 M y • All work shall comply with the local building code(s) � riIwo and with requirements of local AHJ �I E-200 GENERAL NOTES ELECTRIC METAL � EMT KEY PLANE- 300 SATELLITE VIEW TUBING F yy. y T � � E-301 SITE PLAN ELECTRIC VEHICLE EVCS CHARGER x i w ° E 400 ELECTRICAL PLAN STATION GROUNDING E-500 EV CHARGER DETAIL GEC ELECTRODE { � & CONDUCTOR E-501 EV PANEL DETAIL E-600 DETAILS GND GROUND ;a E-601 DETAILS HIGH DENSITY w, HDPE POLYETHYLENE >'f O PHASE t � E 3.0 07.09.25 DESIGN MODIFICATIONS � RNMC RIGID 2.0 05.14.25 COMPLETE DESIGN a NONMETALLIC 1 .0 04.17.25 INITIAL DESIGN REV DATE LAYOUT $f° CONDUIT DESCRIPTION S (S V vO LI XMFR TRANSFORMER y 6 PROJECT NAME ELECTRIC VEHICLE CHARGING STATION INSTALLATION AT 6400 MAIN RD MATTITUCK, NY 11952 AKA 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 SHEET TITLE E-100 COVER SHEET SEAL PROJECT NO.LAUREL LINKS SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH Ys•' ��'^'"^+-n„„� HOMOIdAO i00DIUIlAWNE&GNBLON ° 0 CHECKED BY: kc? 7 O Via. C37Co?k)91 ,gyp w��J i CLIENT,PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 6400 MAIN RD MATTITUCK, NY 11952 1, GENERAL CONIDITIONS c. ANY CUTTING AND PATCHING REQUIRED,DUE TO THE FAILURE TO COMPLY WITH THE ABOVE PROVISIONS,SHALL BE DONE AT NO M, WHERE ELECTTRICAL METALLIC TUBING IS INSTALLED,THE CONNECTORS AND COUPLINGS SHALL BE THE NYLON INSULATED THROAT BUILDING STANDARDS• A. DESCRIPTION OF BID DOCUMENTS EXTRA COST TO OWNER. SUCH CUTTING AND PATCHING SHALL BE DONE UNDER DIVISION ONE,AS APPROVED BY THE ARCHITECT. TYPE AS MANLUFACTURED BY THE THOMAS&BETTS CO.,SERIES 5120 AND 4123 RESPECTIVELY,OR AS ACCEPTABLE. ON TUBING LARGER 1. NEW WIRING DEVICE PLATES SHALL COORDINATE WITH ARCHITECT AND OWNER TO MATCH EXISTING BUILDING STANDARDS.USE ONLY a. THIS 1WRITTEN SPECIFICATIONS,DRAWINGS PLANS AND DETAILS ARE INTENDED TO SERVE JOINTLY AS A BASIS UPON WHICH THE d. THE WORK SHALL BE CAREFULLY LAID OUT IN ADVANCE. WHERE CUTTING,CHANNELING,CHASING OR DRILLING OF FLOORS,WALLS, THAN 1'USE 83ONDING LOCKNUTS AS DESCRIBED ABOVE FOR RIGID CONDUIT. PARTITIONS,CEILINGS OR OTHER SURFACES IS NECESSARY FOR THE PROPER INSTALLATION,SUPPORT OR ANCHORAGE OF ALUMINUM TAP,SUPPORT AND PULL BOXES WITH ALUMINUM CONDUIT.ALL STEEL BOXES SHALL BE PRIMED AND FINISHED IN GRAY CONTRACTOR SHALL SUBMIT A CONTRACT PRICE FOR THE MATERIAL AND LABOR PROVISIONS AND PERFORM REQUIRED RACEWAY,OUTLETS OR OTHER EQUIPMENT,THE WORK SHALL BE CAREFULLY DONE.ANY DAMAGE TO THE BUILDING,PIPING, N, WHERE FLEXIEBLE METALLIC CONDUIT OR TYPE AC OR MC CABLE IS INSTALLED,CONNECTORS SHALL BE THE"TITE BITE"TYPE WITH ENAMEL. DESIGN CONSULTAM� INSTALLATION. NYLON INSULAATED THROATS AS MANUFACTURED BY THE THOMAS&BETTS CO.,SERIES 3110 ORAS ACCEPTABLE•FOR AC OR MC CABLE, b. IT IS TFHE INTENTION OF THIS SPECIFICATIONS,DRAWINGS PLANS AND DETAILS TO CALL FOR FINISHED INSTALLATION WORK,WHICH IS EQUIPMENT OR DEFACED FINISH PLASTER,WOODWORK,METALWORK,ETC.SHALL BE REPAIRED BY SKILLED MECHANICS OF THE TRADES INVOLVED AT NO ADDITIONAL COST TO THE OWNER. INSTALL ANTI-SHORT BUSHINGS AND TERMINATE IN ACCORDANCE WITH MANUFACTURER'S 1N5TRUCTIONS. SUPPORT CABLES PER NEC. 8. DISCONNECTS TESTED,APPROVED BY LOCAL AHJ AND READY FOR OPERATION BY OWNERIUSER. LNG AND ROUG PATCHING FOR INSTALLATION OF HI5 WORK. O. WHERE TERMIIINATING LIQUID TIGHT FLEXIBLE STEEL CONDUIT(SEALTITE),FITTING ASSEMBLY SHALL BE SEALING TYPE CONSISTING OF A. DISCONNECTS SHALL CONFORM TO NEMA AND U.L.STANDARDS,AND BE INSTALLED WHERE SHOWN ON DRAWINGS OR REQUIRED BY c. THIS(CONTRACTOR SHALL VISIT THE SITE AND ADJOINING AREAS,EXAMINE AND BE FAMILIAR WITH ALL EXISTING CONDITIONS AND e• THIS CONTRACTOR SHALL DO ALL CUTTING,CHAS H DETEIRMINE THE IMPACT ON THE EXECUTION OF WORK OF THIS CONTRACT.THIS CONTRACTOR SHALL PERFORM THIS PRIOR TO THE f. UNLESS ASSIGNED TO OTHER CONTRACTOR(S)AS PART OF CONTRACT AGREEMENT,THE GENERAL CONTRACTOR SHALL FINISH STEEL GLAND,,NYLON RING AND GROUND CONE A THE OUTSIDE AND A NYLON INSULATED THROAT FITTING ON THE INSIDE. FITTINGS CODE.DISCONNECTS SHALL BE HORSEPOWER RATED UNITS TO MAXIMUM SIZES LISTED BY U.L, SWITCHES USED FOR SERVICE SUBMISSION OF HER OR HIS PROPOSAL.SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN PATCHING AND REPAIRS. SHALL BE THO)MAS&BETTS CO„SERIES 53310R AS ACCEPTABLE. ENTRANCE SHALL BE APPROVED FOR SERVICE AND PROVIDED WITH NEUTRAL CONNECTION. UIPMENT OR MATERIALS ALL CUTTING AND DRILLING SHALL BE MACHINE CUT WITH POWER DRIVEN TOOLS. CONDUIT PENETRATIONS SHALL BE CORE DRILLED. P. WHERE PASSIIING THROUGH FIRE RATED FLOORS OR WALLS USE U.L.LISTED FIRE RATED FITTINGS WHICH WILL PREVENT THE SPREAD OF B. PROVIDE QUICK-MAKE,QUICK-BREAK MECHANISM,SINGLE THROW WITH EXTERNAL OPERATING HANDLE MECHANICALLY INTERLOCKED EXAMIINATION HAS BEEN MADE AND LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR,EQ 9• TERED WH CH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, h. WHERE CONDUITS,MOUNTING CHANNELS,OUTLET,JUNCTION,OR PULL BOXES ARE MOUNTED ON A PAINTED SURFACE,OR A FIRE OR PRODUCTS OF COMBUSTION,NELSON"FLAMESEAL"OR AS ACCEPTABLE OR UL APPROVED FIRE STOP SYSTEM. WITH ENCLOSURE COVER TO PROVIDE NORMAL ACCESS TO INSIDE OF ENCLOSURE WHEN DISCONNECT IS IN OFF POSITION ONLY AND REQUIRED BECAUSE OF DIFFICULTIES ENCOUN I d. THIS iCONTRACTORS SHALL PROVIDE ALL ITEMS OF LABOR OR MATERIALS NOT SPECIFICALLY INDICATED,BUT REQUIRED TO SURFACE TO BE PAINTED,THEY SHALL BE PAINTED TO MATCH THE SURFACE. WHENEVER SUPPORT CHANNELS ARE CUT,THE BARE Q. HIGH AND LOWN TENSION FLOOR FITTINGS SHALL MATCH EXISTING FITTINGS.USE NEMA 5-20 CONFIGURATION WIRING DEVICE IN HIGH WITH MEANS TO BYPASS THE MECHANICALLY INTERLOCKED DOOR AND HANDLE. COMPLETE THE INTENDED INSTALLATIONS. METAL SHALL BE COLD GALVANIZED. TENSION QUTL'LET. C• PROVIDE MEANS TO LOCK THE OPERATING HANDLE IN THE OPEN AND CLOSED POSITION.DESIGNATE ON THE ENCLOSURE THE OPEN e. THE CONTRACTORS SHALL COORDINATE THEIR WORK OR ADJUST SAME TO THAT OF OTHER TRADES,IN ORDER THAT CONFLICTS IN G. COORDINATION WITH OTHER TRADES AND LOSED POSITION OF THE OPERATING HANDLE. SPACE LOCATIONS DO NOT OCCUR. 5. CONDUCTORS D. SWITCHES SHALL BE HEAVY DUTY TYPE. f. ANY APPARATUS,APPLIANCE,MATERIAL,OR WORK NOT SHOWN ON DRAWINGS,BUT MENTIONED IN THE SPECIFICATIONS,OR VICE a. PRIOR TO STARTING ANY WORK,PURCHASE OF EQUIPMENT,ETC.,COORDINATE WORK WITH OTHER TRADES,CONFER WITH OTHER A. ALL WIRES ANND CABLE SHALL BE COPPER TYPE THHN-THWN FOR FEEDERS AND FOR BRANCH CIRCUITS IN CONDUIT.NO WIRE SMALLER E. SWITCHES SHALL BE OF THE DOUBLE STATIONARY CONTACT TYPE 1MTHORC-QUENCHING DEVICE ON EACH POLE FOR DISCONNECTS VERSiA,OR ANY INCIDENTAL ACCESSORIES,OR MINOR DETAILS NOT SHOWN BUT NECESSARY TO MAKE THE WORK COMPLETE IN ALL CONTRACTORS WHOSE WORK MIGHT AFFECT THIS INSTALLATION,AND ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENT IN THAN#12 AWGG SHALL BE USED FOR BRANCH CIRCUITS.ALL CONTROL CONDUCTORS SHALL BE#14 AWG. RATED ABOVE 250 VOLTS. RESPECTS AND READY FOR OPERATION,EVEN IF NOT PARTICULARLY SPECIFIED,SHALL BE PROV►DED WITHOUT ADDITIONAL PROPER SEQUENCE AND RELATION TO THE WORK AND EQUIPMENT OF OTHERS,WITH THE BUILDING CONSTRUCTION AND WITH EXPEENSE TO THE OWNER. ARCHITECTURAL FINISH SO THAT IT WILL HARMONIZE IN SERVICE AND APPEARANCE. IN THE EVENT THERE IS A CONFLICT IN B. CONNECTIONSS FOR WIRE#8 AND SMALLER SHALL BE MADE WITH T&B"PIGGY PIGTAILS"OR AS ACCEPTABLE. TERMINATE STRANDED F. SWITCHES SHALL BE FU5IBLE OR UNFUSIBLE AS SHOWN ON THE DRAWINGS AND/OR AS REQUIRED• g. THE CCONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK WITH ITS COMPLETION AND FINAL ACCEPTANCE AND SHALL REPLACE ANY COORDINATION BETWEEN TRADES,THE OWNER OR HIS REPRESENTATIVE WILL RESOLVE IT. MAXIMU NUMBBE AND SMALLER IN SPADE LUGS• G. FUSED SWITCHES SHALL SE COMPLETE WITH CLASS"RK-5"OR"L"FUSES AS REQUIRED. OF SA4ME,WHICH MAY SE DAMAGED,LOST OR STOLEN,WITHOUT ADDITIONAL COSTS TO THE OWNER. C. MAXIMUM NUMNBER OF HOME RUNS IN A COMMON CONDUIT SHALL BE 3. A DEDICATED NEUTRAL SHALL BE RUN FOR EACH BRANCH H. ALL SWITCHES IN INDOOR,DRY LOCATIONS SHALL BE MOUNTED IN NEMA TYPE I ENCLOSURES,SWITCH ES INSTALLED OUTDOOR OR IN h. SPECIFICATIONS,IN GENERAL,DESCRIBE QUALITY AND CHARACTER OF MATERIALS AND EQUIPMENT.THE ACCOMPANYING H. TRENCHING,EXCAVATING AND STRUCTURES CIRCUIT(SHAFRE NEUTRAL IS NOT ALLOWED). WET AND DAMP LOCATIONS SHALL HAVE NEMA 3R RATING.. DRAVWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT AND EXTENT OF WORK TO BE PERFORMED. THE LOCATIONS FOR a. PRIOR TO ANY TRENCHING EXCAVATION,SOIL BORINGS AND/OR UNDERGROUND EXPLORATION,THE CONTRACTOR SHALL NOTIFY D. ALL WIRES ANAD CABLES IN PULL,SPLICE AND CABLE SUPPORT BOXES,IN PANELS AND POINTS OF TERMINATION SHALL BE BUNDLED AND EQUIFPMENT AND MATERIAL AS SHOWN ON THE DRAWINGS ARE APPROXIMATE.IT SHALL BE UNDERSTOOD THAT THEY ARE SUBJECT ALL UTILITIES UNDER NEW JERSEY STATE INDUSTRIAL CODE. LACED BY CIRQCUITS AND TAGGED USING NYLON TIEWRAP MATERIAL AND US►NG FLAME RESISTING TAGS OF ADHESIVE MATERIAL.TAGS 10.GROUNDING&BONDING TO SWCH MODIFICATION AS MAY BE FOUND NECESSARY TO MEET JOB CONDITIONS.SUCH CHANGES SHALL BE MADE BY THIS b. FOUNDATION,REBAR AND CONCRETE SLAB SHALL BE INSTALLED UNDER CONTROLLED INSPECTION• SHALL IDENTIFFY CABLES AND PIECES OF EQUIPMENT SERVED. TAGS SHALL BE T&B"TY-RAP"OR"E-Z-CODE"OR AS ACCEPTABLE. A. ALL GROUNDING AND BONDING AND THEIR INSTALLATION SHALL BE IN COMPLIANCE WITH ARTICLE 250 IF APPLICABLE VERSION OF NEC CONTRACTOR or VENDOR: CONTTRACTOR AT NO ADDITIONAL CHARGE. c. IT SHALL BE ASSUMED THAT THE EXISTING UTILITIES OR OTHER UNDERGROUND LINES IN AND ADJACENT TO THE CONSTRUCTION E. ALL WIRING APND CABLE SHALL BE COLOR CODED AS FOLLOWS: B. CONNECT SYSTEM COMPONENTS MECHANICALLY AND ELECTRICALLY TO PROVIDE AN INDEPENDENT RETURN PATH TO GROUND f. SCALLED AND INDICATED DIMENSIONS ARE APPROXIMATE AND ARE FOR ESTIMATING PURPOSES ONLY.BEFORE PROCEEDING WITH WORK ARE PRESENTLY IN PERFECT WORKING ORDER.IN THE EVENT OF THE EXISTING UTILITY OR LINES BREAKDOWNS IN THE PHASE COLOR ELECTRODE. WORBK,CHECK AND VERIFY ALL DIMENSIONS. CONSTRUCTION AREA,THIS CONTRACTOR SHALL MAKE IMMEDIATE REPAIRS WITHOUT COST TO THE OWNER. 208/120V 4801277V C. ALL FEEDERS AND BRANCH CIRCUITS SHALL HAVE A DEDICATED EQUIPMENT GROUNDING CONDUCTOR SEIZED PER NEC TABLE 250.122 j. ALL WETHODS Of WORKMANSHIP AND CONSTRUCTION AND DETAILS OF SAME NOT SPECIFICALLY DESCRIBED HEREIN SHALL BE d. ALL FIELD WORK SHOULD PROCEED ONLY AFTER EACH EXISTING UNDERGROUND UTILITY OR SERVICE LINES IN CONSTRUCTION A OR i BLACK BROWN ,��+, C�O L L MARKED BY THIS CONTRACTOR.THEN WORK IS TO PROCEED W/CONTROLLED EXCAVATION ITH HAND DIGGING D. USE EXOTHERMIC WELDING PROCESS FOR INACCESSIBLE CONNECTIONS• O ll SUBJUECT TO THE APPROVAL OF THE OWNER OR HIS REPRESENTATIVE. AREA ARE C EAR Y � B OR 2 RED ORANGE �T k. MAKEE ADJUSTMENTS THAT MAY BE NECESSARY OR REQUESTED IN ORDER TO RESOLVE SPACE PROBLEMS,PRESERVE HEADROOM, TO EXPOSE KNOWN UTILITIES)UNTIL THE AREA HAS BEEN OPENED SUFFICIENTLY TO UTILIZE MASS EXCAVATION. C OR 3 BLUE YELLOW E. EXTEND EXISTING SYSTEM GROUND TO INCLUDE ALL THE ELECTRICAL WORK IN THE SCOPE OF THIS ALTERATION. r` ., (-- , AND(AVOID ARCHITECTURAL OPENINGS,STRUCTURAL MEMBERS AND WORK OF OTHER TRADES. e. SHORING IS REQUIRED IF ANY EXCAVATION IS GREATER THAN 5 FT,DEEP AND SAFE SLOPE OF SIDE WALLS IS NOT POSSIBLE,OR IF NEUTRAL WHITE OR GRAY F. GROUND EACH TRANSFORMER AND/OR OTHER SEPARATELY DERIVED POWER SYSTEM BY RUNNING A CONDUCTOR FROM NEUTRAL TO C':l/'!l1%<///Illy C;/.,/l, 1. TYPICCAL DETAILS,WHERE SHOWN ON THE DRAWINGS,APPLY TO EACH AND EVERY ITEM OF THE PROJECT WHERE SUCH ITEMS ARE REQUIRED BY SOIL CONDITIONS. EQUIP GROUND GREEN GREEN A LUG WELDED OR BRAZED TO THE INTERIOR OF THE ENCLOSURE. APPLICABLE. TYPICAL DETAILS ARE NOT REPEATED IN FULL ON THE PLANS,AND ARE DIAGRAMMATIC ONLY,BUT WITH THE INTENTION f. CONSTRUCTION BARRICADES WITH LIGHTS AND FLAGS ARE REQUIRED ALL AROUND OPEN EXCAVATIONS AND BE PROVIDED BY THIS F. ALL POWER CAABLES SHALL BE TERMINATED,SPLICED AND TAPPED WITH COLOR-KEYED,CIRCUMFERENTIAL COMPRESSION G. RUN GROUNDING CABLE TO NEAREST BUILDING MAJOR STRUCTURAL MEMBER;OR,IF NOT READILY AVAILABLE,TO THE NEAREST 1-1/2" THATT SUCH DETAILS SHALL BE INCORPORATED IN FULL. CONTRACTOR. CONNECTORS3 AS MANUFACTURED BY THE THOMAS&BETTS CO.,SERIES 54000 OR AS ACCEPTABLE,EXCEPT IN MOTOR CONTROLLERS, OR LARGER COLD WATER PIPE,USE ONLY A SINGLE PIPE CLAMP. m, IT 1S-THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO PROVIDE A COMPLETE WORKABLE SYSTEM READY FOR THE OWNER'S OPERATION.ANY ITEM NOT SPECIFICALLY SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS,BUT NORMALLY 1, DAMAGE TO PROPERTY SWITCHES ANGD PANELBOARDS WHERE LUGS CANNOT BE CHANGED.USE MANUFACTURER'S RECOMMENDED TOOLING TO APPLY. H. BRAISED FLOOR AREAS,ALSO GROUND TO RAISED FLOOR.WHERE FLEXIBLE METALLIC CONDUIT IS USED,INSTALL IS INTERNAL REQUIRED TO CONFORM TO THE INTENT,ARE TO BE CONSIDERED A PART OF THE CONTRACT. a. RESTORE TO ITS ORIGINAL CONDITION,WITHOUT EXTRA PAYMENT,ANY OF THE OWNER'S PROPERTY THAT BECOMES DAMAGED DUE G. LUGS SHALL BBE THETWO-HOLE TYPE•INSULATE ALL SPLICES AND TAPS WITH HEAT SHRINKABLE INSULATION,RAYCHEM OR THOMAS& BONDING T GROUTOR.WHERE AN ISOLATED GROUND SYSTEM 15 USED,RUN AN ADDITIONAL CONDUCTOR FOR THE ISOLATED AND n. IF ANIY PART OF SPECIFICATIONS OR DRAWINGS APPEARS UNCLEAR OR CONTRADICTORY,CONSULT THE ARCHITECT/DESIGN TO THE NEGLIGENCE OF EMPLOYEES OR AGENTS OF THE CONTRACTORS. SUCH REPAIRS SHALL BE ACCEPTABLE TO THE OWNER. BETTS OR AS EACCEPTABLE.FURNISH AND INSTALL LUGS WHERE NOT FURNISHED WITH EQUIPMENT. EQUIPMENT GROUNDS. 103 SCh OOI St PROFFESSIONAL FOR INTERPRETATION AND DECISION AS EARLY AS POSSIBLE DURING BIDDING PERIOD. DO NOT PROCEED WITH INCLUDE ALL COSTS IN THE BID PRICE FOR PERFORMING SHUTDOWNS ON PREMIUM TIME.MODULES,ETC. H. WHERE CABLES PASS THROUGH FIRE RATED,FIRE RESISTANT AND/OR FIRE STOPPED FLOORS,WALLS,AND ABOVE CEILING SMOKE 1. GROUND MOTORS BY CONNECTING A CONDUCTOR FROM A GROUNDING BUSHING IN THE STARTER TO THE MOTOR FRAME.INSTALL WORM WITHOUT THE ARCHITECT/DESIGN PROFESSIONAL'S DECISION. BARRIERS USEE CABLE SLEEVES THAT PREVENT THE SPREAD OF FIRE OR PRODUCTS OF COMBUSTION.SLEEVES SHALL BE NELSON TERMINAL IS MECHANICALLY CONN CTEDITO THE FRAME TORS AND TERMINATED IN THE MOTOR CONNECTION BOX PROVIDING THE Lindenhurst, N Y 11757 o. UNLESS SPECIFIED OTHERWISE HEREIN,CONTRACTOR SHALL BASE HERIHIS BID PROPOSAL WITH ALL WORK TO BE PERFORMED ON A 1. SHUTDOWNS ELECTRIC"MUULTI-CABLE TRANSIT',NELSON TLAMESEAL"OR AS ACCEPTABLE. J• RUN ADDITIONAL GROUND CONDUCTOR IN PRIMARY AND SECONDARY CONDUITS TO TRANSFORMERS AND TO ALL EQUIPMENT STRA4IGHT TIME NORMAL WORKING DAY. a. WHEN THE INSTALLATION OF NEW WORK REQUIRES THE SHUTDOWN OF EXISTING OPERATING SYSTEMS,THE CONNECTION OF THE p. ANY IQUESTIONS OR DISAGREEMENTS ARISING AS TO THE TRUE INTENT OF THIS SPECIFICATION OR THE DRAWINGS OR THE KIND AND NEW WORK SHALL BE PERFORMED ONLY AFTER GIVING AT LEAST 72 HOURS NOTICE TO,AND OBTAINING THE WRITTEN 6. PANELS AND/OR PAANELBOARDS CONNECTED BY FLEXIBLE CONDUIT TO IMPROVE GROUNDING OF FLEXIBLE CONDUIT. QUALLITY OF WORK REQUIRED THEREBY SHALL BE DECIDED BY THE ARCHITECT/DESIGN PROFESSIONAL,WHOSE INTERPRETATIONS AUTHORIZATION OF,THE OWNER. A. PROVIDE COMNPUETE PANELS OR PANELBOARDS PER CONTENT INDICATED ON THIS DRAWINGS PACKAGE 11.TRANSFORMERS-HIGH EFFICIENCY THERREOF SHALL BE FINAL,CONCLUSIVE,AND BINDING ON ALL PARTIES. B. PROVIDE TWO)(2)KEYS FOR EACH CABINET LOCK, LEGAL NOTES q. IN CAUSE OF DISAGREEMENT BETWEEN DRAWINGS AND SPECIFICATIONS,OR WITHIN EITHER DOCUMENT ITSELF,THE BETTER J. SHOP DRAWINGS C. SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE CIRCUIT BREAKERS COMPATIBLE WITH EXISTING PANELS. A• PROVIDE TRANSFORMERS DRY-TYPE DISTRIBUTION TRANSFORMERS WITH PRIMARY AND SECONDARY VOLTAGES OF 600V AND LESS AND QUALLITY,GREATER QUANTITY OR MORE COSTLY WORK SHALL BE INCLUDED IN THE CONTRACT PRICE AND THE MATTER REFERRED a. SUBMIT REQUIRED OR REQUESTED SHOP DRAWINGS OF ALL EQUIPMENT,DEVICES,COMPONENTS,CONDUCTORS,CONDUITS, D. SUBJECT TO COMPLIANCE WITH REQUIREMENTS PROVIDE PRODUCTS BY THE FOLLOWING MANUFA CAPACITY RATINGS THROUGH 1000 kVA.REFER TO DRAWING FOR SPECIFIC TRANSFORMER RATING REQUIREMENTS. TO Ti'HE ARCHITECT/DESIGN PROFESSIONAL'S ATTENTION FOR DECISION AND10R ADJUSTMENT. FITTINGS AND ASSEMBLY AND OBTAIN WRITTEN REVIEW COMMENTS FROM ENGINEER OF RECORD,BEFORE ORDERING OR CTURERS:SQUARE D,SIEMENS, B, WHERE INDICATED,PROVIDE WALL-MOUNTING AND STRUCTURE-HANGING SUPPORTS INCLUDING VIBRATION ISOLATION. "It is a violation of the state education law for any person, r, IF DIRRECTED BY THE ARCHITECT/DESIGN PROFESSIONAL,WITHOUT EXTRA CHARGE,MAKE REASONABLE MODIFICATIONS IN THE GENERAL ELEECTCO SISTIN OR LOCAL MANUFACTURER PROVIDING LISTED PRODUCT. C. REFERENCES;NFPA 70,NEMA ST20 UL 1561 UL 250 EPA OF 2005 PUBLIC LAW 109-58-AUG. 2 unless he or she is actin under the direction of a INSTALLING ANY MATERIAL OR EQUIPMENT. ALL SUBMITTAL TO BE IN DIGITAL FORM(PDF FILE FORMAT), E. PROVIDE PANEEL CONSISTING OF AN ASSEMBLY OF BRANCH CIRCUITS SWITCHING AND PROTECTIVE DEVICES CIRCUIT BREAKERS, 8, 005 g LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF OTHER TRADES OR FOR PROPER EXECUTION OF THE WORK. ( COMPLY WITH ALL RULES FROM DEPARTMENT OF ENERGY CONTAINED IN THE LATEST REVISIONS OF 10 CFR 429 AND 10 CFR 431, licensed professional engineer to alter an item in anyway, s. ALL WVORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS SHALL BE INCLUDED UNDER THE BASE BID,EXCEPT WHERE THERE IS K. AS-BUILT DRAWINGS SWITCH AND FFUSE UNITS,OR COMBINATION THEREOF)MOUNTED INSIDE A DEAD FRONT ENCLOSURE.PROVIDE THE NUMBER AND SIZE D. IEEE C57.12.91-LOWSOUND-LEVEL RE UIREMEN SPECIFIC REFERENCE TO EXCLUSIONS AND INCORPORATED IN OTHER QUOTATIONS. 0 0 INSTALLATION THIS CONTRACTOR SHALL FURNISH°AS-BUILT'DRAWINGS CONSISTING OF A COMPLETE SET OF THESE BRAANCH CIRCUIT DEVICES AS INDICATED BY THE CIRCUITING,ON THE DRAWINGS,AND IN THE SCHEDULES.LOCATIONS OF O TS. MINIMUM OF 3 DBA LESS THAN NEMA ST 20 STANDARD SOUND LEVELS WHEN on this drawing and/or in this specification in o nyway. If t THIS'SECTION OF THE SPECIFICATIONS COVERS THE ELECTRICAL SYSTEMS OF THE PROJECT.IT INCLUDES WORK PERFORMED BY a• UPON COMPAND N F FACTORY TESTED ACCORDING TO OFAutoCADANDPDFFORMATDRAWINGS,INDICATINGINANEATANDACCURATEMANNER,ACOMPLETERECORDOFALLCOMPLETE CIRCUITBREAAKERSSHALLBEASINDICATEDINTHESCHEDULES, any such item is altered, the altering engineer shall affix to THE(ELECTRICAL TRADES AS WELL AS TRADES NOT NORMALLY CONSIDERED AS ELECTRICAL TRADES. INSTALLATION WORK AND CHANGES TO THE ORIGINAL DESIGN OF THE WORK. F. POWER AND DISTRIBUTION PANELBOARDS-CIRCUIT BREAKER TYPE E. BASE BID ACCEPTABLE MANUFACTURERS;SQUARE D,EATON,SIEMENS,GENERAL ELECTRIC. the item his or her seal and the notation "altered by" u. PROWIDE ALL INCIDENTALS,EQUIPMENT,APPLIANCES,SERVICES,HOISTING,SCAFFOLDING,SUPPORTS,TOOLS,SUPERVISION,LABOR a. SHALL BE(OF THE VOLTAGE AND AMPERAGE SHOWN,3 PHASE,4 WIRE,44,000 AMPS AIC MINIMUM,UNLESS SHOWN OTHERWISE,DEAD F. TRANSFORMERS FOR NON-CRITICAL LOADS:15 kVA AND LARGER SHALL BE 150°C TEMP RISE ABOVE 40°C AMBIENT WITH 4 K FACTOR. followed by his or her signature and the date of such CONSUMABLE ITEMS,FEES,LICENSES,ETC.,NECE55ARY TO PROVIDE COMPLETE SYSTEMS.PERFORM START-UP AND CHECKOUT ON L. INSURANCE FRONT,CIFRCUITBREAKER TYPE,WITH MAIN CIRCUIT BREAKER OR MAIN LUGS ONLY AS SHOWN,COPPER BUS,FULLY RATED NEUTRAL alteration, and a specific description of the alteration." EACH REM AND SYSTEM TO PROVIDE FULLY OPERABLE SYSTEMS. a. FURNISH ADEQUATE LIABILITY INSURANCE AND BONDING AS REQUIRED BY THE OWNER,PRIOR ANY WORK. AND GROUND BARS,NEMA TYPE 1(INDOOR INSTALL)OR NEMA 3R(OUTDOOR INSTALL)ENCLOSURE AND SURFACE TRIM.BLANK G. TRANSFORMERS FOR CRITICAL LOADS:TEMPERATURE RISE 115°C RISE OR 80°C AND IF SPECIFICALLY NOTED ON CONTRACT v. EXAMAINE AND COMPARE THE ELECTRICAL DRAWINGS AND SPECIFICATIONS WITH THE DRAWINGS AND SPECIFICATIONS OF OTHER CIRCUIT BFREAKER SPACES SHALL BE FULLY BUSED AND READY TO ACCEPT FUTURE CIRCUIT BREAKERS. TRADES,AND REPORT ANY DISCREPANCIES BETWEEN THEM TO THE ARCHITECT/DESIGN PROFESSIONAL AND OBTAIN FROM HIM M. TEMPORARY LIGHT AND POWER G. LIGHTING AND)RECEPTACLE PANELS-CIRCUIT BREAKER TYPE DOCUMENTS)WITH 9 K-FACTOR. • Any errors and omissions in the drawing are to be WRITFTEN INSTRUCTIONS FOR CHANGES NECESSARY IN THE WORK,AT TIME OF BID,THE MOST STRINGENT REQUIREMENTS MUST BE a. WHERE NECESSARY THIS CONTRACTOR SHALL PROVIDE TEMPORARY LIGHT AND POWER FOR THE NEW CONSTRUCTION AREAS,IN a. PANELS SHiALL BE OF THE VOLTAGE,AMPERAGE AND NUMBER OF POSITIONS SHOWN,3 PHASE,4 WIRE,22,000 AIC MINIMUM,UNLESS H. THE MAXIMUM TEMPERATURE OF THE TOP OF THE ENCLOSURE SHALL NOT EXCEED 50°C RISE ABOVE A 40°C AMBIENT. checked by the general contractor and rel dyed to the INSTALL A IN SAID BID, ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ACCEPTED STANDARDS ESTABLISHED BY O.S.H.A.ENERGY COSTS WILL BE SHOWN 01THERWISE,WITH MAIN CIRCUIT BREAKER OR MAIN LUGS ONLY AS SHOWN,COPPER BUS,FULLY RATED NEUTRAL AND architect/EOR w. INST/ALL AND COORDINATE THE ELECTRICAL WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK BORNE BY THE OWNER. GROUND EBARS,NEMA TYPE 1(INDOOR INSTALL)OR NEMA 3R(OUTDOOR INSTALL)ENCLOSURE AND SURFACE OR FLUSH TRIM AS 1, MANUFACTURER MARKINGS:EACH TRANSFORMER SHALL BE PROVIDED WITH A NAMEPLATE GIVING THE FOLLOWING INFORMATION; • Do not scale drawings BEFORE INSTALLATION,MAKE PROPER PROVISIONS TO AVOID INTERFERENCES IN A MANNER APPROVED BY THE ARCHITECTIDESIGN SHOWN.IM MAIN CIRCUIT BREAKER PANELS,THE MAIN CIRCUIT BREAKER SHALL BE SEPARATE FROM AND NOT MOUNTED IN FEEDER NAME OF MANUFACTURER,RATED KILOVOLT-AMPERES,FREQUENCY,PRIMARY AND SECONDARY,VOLTAGE,IMPEDANCE OF • All work shall comply with the local building code(s) PROFFESSIONAL.ALL CHANGES REQUIRED IN THE WORK OF THE CONTRACTOR,CAUSED BY HIS NEGLECT TO DO SO,SHALL BE MADE N. TESTING BREAKER IPOSITIONS, TRANSFORMERS 25 KVA AND LARGER,REQUIRED CLEARANCES FOR TRANSFORMERS WITH VENTILATING OPENINGS,AMOUNTAND KIND and with requirements of local AHJ BY HIIM AT HIS OWN EXPENSE. a. ALL PARTS OF THE WORK AND ASSOCIATED EQUIPMENT SHALL BE TESTED AND ADJUSTED TO WORK PROPERLY AND BE LEFT IN H. PANELS CONSTTRUCTION OF INSULATING LIQUID WHERE USED,FOR DRY-TYPE TRANSFORMERS,TEMPERATURE CLASS FOR THE INSULATION SYSTEM x. ALL;SPECIAL AND SUPPLEMENTARY CONDITIONS AND OTHER DOCUMENTS SUCH AS DELINEATED UNDER THE"OWNER-CONTRACTOR PERFECT OPERATING CONDITION;THIS SHALL INCLUDE ELECTRICAL MEGGER TESTS BETWEEN PHASES AND BETWEEN EACH PHASE a. RIGID REM10VABLE ASSEMBLY OF COPPER BUS BARS AND INTERCHANGEABLE BOLTED BRANCH CIRCUIT DEVICES. AGRFEEMENT"ARE HEREBY MADE A PART OF THESE SPECIFICATIONS. AND GROUND OF ALL FEEDERS AND SUB-FEEDERS. CORRECT DEFECTS DISCLOSED BY THESE TESTS WITHOUT ANY ADDITIONAL b, BUS BARS SIZED IN ACCORDANCE WITH UL STANDARDS TO LIMIT TEMPERATURE RISE ON ANY CURRENT CARRYING PART TO A J. CONSTRUCTION SHALL BE:FACTORY-ASSEMBLED AND-TESTED, BE COOLED UNITS FOR 60-HZ SERVICE,CROSS: GRAINSHALL BED, NON-AGING SILICON STEEL,COILS: TRANSFORMER COILS SHALL BE OF THE CONTINUOUS WOUND CONSTRUCTION AND SHALL BE B. LAWS,ORRDNNANCES,PERMITS AND FEES COST TO THE OWNER. REPEAT TESTS ON REPAIRED OR REPLACED WORK.ALL NEWLY INSTALLED EQUIPMENT SHALL 8E TESTED PER MAXIMUM IOF 65 DEGREES C ABOVE AN AMBIENT OF 40 DEGREES C MAXIMUM• KEY PLAN APPLICABLE STANDARDS AND MANUFACTURER INSTALLATION MANUAL. c. BUS BARS DRILLED TO PERMIT BRANCH CIRCUIT DEVICES OF ALL SIZES AND NUMBER OF POLES TO BE INTERCHANGEABLE AND IMPREGNATED WITH NONHYGROSCOPIC,THERMOSETTING VARNISH. COILS SHALL BE WITHOUT SPLICES,EXCEPT FOR TAPS. a. ALL/!INDICATED AND SPECIFIED INSTALLATION SHALL BE PERFORMED IN COMPLIANCE WITH LOCAL APPLICABLE GOVERN CODES,THE INSTALLED IN ANY SPARE SPACE OF SUFFICIENT SIZE,WITHOUT DISTURBING ADJACENT UNITS;WITHOUT REMOVING MAIN BUS OR K. COIL INTERNAL CONNECTIONS: BRAZED OR PRESSURE TYPE,COPPER AND SHALL BE OF THE CONTINUOUS WOUND CONSTRUCTION AND ALL ERICANS WITH DISABILITIES ACT(ADO),STANDARDS AND EENSEDE LECTRICI NL MANUFACTURER INSTALLATION MANUAL. 0. SEISMIC REQUIREMENTS BRANCH CIRCUIT CONNECTORS AND WITHOUT MACHINING,DRILLING,OR TAPPING IN THE FIELD. SHALL BE IMPREGNATED WITH NON-HYGROSCOPIC,THERMOSETTING VARNISH CONSTRUCTED WITH LOW HYSTERESIS AND EDDY b. ALL EELECTRIC WORK IS TO BE PERFORMED BY ONLY BY A tlCl_NSED ELECTRICIAN WITH VALID LICENSED FOR AREA WHERE WORK TO BE PPERFORMED. a. ALL EQUIPMENT SHALL BE BOLTED TO STRUCTURE AND/OR TO GROUND TO ALLOW FOR MINIMUM 0.5G OF ACCELERATION.LIFE d. ARRANGE BUS IN SEQUENCE OR DISTRIBUTED PHASING SO THAT MULTI-POLE CIRCUIT BREAKER CAN REPLACE ANY GROUP OF CURRENT LOSSES. MAGNETIC FLUX DENSITIES ARE TO BE KEPT WELL BELOW THE SATURATION POINT TO PREVENT CARE c. THIS)CONTRACTOR IS REQUIRED PREPARE ALL NECESSARY PERMIT FILING DOCUMENTS AND FILED THOSE WITH LOCAL AUTHORITY SAFETY EQUIPMENT, PIPS AND CONDUITS SHALL BE BOLTED TO STRUCTURE TO ALLOW FOR 1,OG OF ACCELERATION.BOLT POINTS SINGLE CIRtCUIT BREAKERS OF THE SAME SIZE. OVERHEATING. HAVIIING JURISDICTION.ALL FILING DOCUMENTS DRAWINGS FORMS etc. SHALL BE PREPARED IN FULL COMPLIANCE WITH THE AND DIAMETER OF INSERTS SHALL BE SUBMITTED AND VERIFIED AS PART OF THE CONTRACTOR'S SUBMISSION FOR EACH PIECE OF e. FULLSIZE i(100%-RATED)INSULATED NEUTRAL BARS SHALL BE INCLUDED FOR PANELBOARDS SHOWN WITH NEUTRAL,NEUTRAL ( ) EQUIPMENT AND CERTIFIED BY A LICENSED CIVIL OR STRUCTURAL ENGINEER. BUSING SHALL HAVE A SUITABLE LUG FOR EACH OUTGOING FEEDER REQUIRING A NEUTRAL CONNECTION•200%-RATED NEUTRALS L. THE COMPLETED CORE AND COIL SHALL BE BOLTED TO THE BASE OF THE ENCLOSURE BUT ISOLATED BY MEANS OF RUBBER LOCAL AHJ REQUIREMENTS.ALL TART,UNTIL ERM WITH THE FILING PROCESS N THIS CONTRACTOR M THE RELEVfTY. d. NO IDNSTALLAl10N WORK SHALL START,UNTIL PERMIT IS OBTAINED AND CLEARANCE IS RECEIVED FROM THE RELEVANT LOCAL b, ALL STRUCTURALLY SUSPENDED OVERHEAD EQUIPMENT SHALL BE FOUR-POINT INDEPENDENTLY BRACED WITH TYPE ll SEISMIC SHALL BE;SUPPLIED FOR PANELS DESIGNATED ON DRAWINGS WITH OVERSIZED NEUTRAL CONDUCTORS AND PANELS SERVED FROM VIBRATION-ABSORBING MOUNTS. THERE SHALL BE NO METAL-TO-METAL CONTACT BETWEEN THE CORE AND COIL AND THE ENCLOSURE BUILIDING DEPARTMENT(AHJ)OR OTHER GOVERN BODY• RESTRAINING SYSTEM. K-RATED(TRANSFORMERS. EXCEPT FOR A FLEXIBLE SAFETY GROUND STRAP. SOUND ISOLATION SYSTEMS REQUIRING THE COMPLETE REMOVAL OF ALL FASTENING e, SHOULD ANY CHANGE IN DRAWINGS OR SPECIFICATIONS BE REQUIRED TO COMPLY WITH GOVERNMENTAL REGULATIONS,THE NOTE:IF EQUIPMENT IS RIGIDLY FASTENED TO CONDUIT,DIAMETER AND DISTANCE REQUIREMENT FROM SUPPORT APPLIES. f. PROVIDE WINIMUM 50%RATED NON-INSULATED GROUND BUS IN EACH PANELBOARD.CONNECT TO GROUND LUG.GROUND BUS DEVICES WILL NOT BE ACCEPTABLE. CONTRACTOR SHALL NOTIFY ARCHITECT/DESIGN PROFESSIONAL PRIOR TO EXECUTION OF THE WORK.THE WORK SHALL BE CARRIED c. INSTALL SEISMIC RESTRAINING SYSTEM TYPE II:TAUT FOR OVERHEAD SUSPENDED UNISOLATED EQUIPMENT,AND SLACK WITH SHALL HAWE SUFFICIENT CAPACITY FOR ALL BRANCH CIRCUITS.PROVIDE AN ADDITIONAL ISOLATED GROUND BUS WHERE REQUIRED. M• THE CORE OF THE TRANSFORMER SHALL BE VISIBLY GROUNDED TO THE ENCLOSURE BY MEANS OF A FLEXIBLE GROUNDING OUT ACCORDING TO THE REQUIREMENTS OF SUCH CODE IN ACCORDANCE WITH THE INSTRUCTION OF THE ARCHITECT/DESIGN CABLE DEFLECTION FOR ISOLATED SYSTEMS. g. ENCLOSURE-CODE GAUGE STEEL BOX GALVANIZED. PROIFESSIONAL AND AT NO ADDITIONAL COST TO THE OWNER, d. SEISMICALLY RESTRAIN ALL CONDUITS WITH CENTER BRACING OR TYPE 11 RESTRAINING SYSTEM IN ACCORDANCE WITH SMACNA h. PROVIDE A'A WELDED GROUND CONNECTOR TO INSIDE OF ENCLOSURE. CONDUCTOR SIZED IN ACCORDANCE WITH APPLICABLE UL AND NEC STANDARDS. GUIDELINES TO COMPLY WITH THE LATEST ADDITION OF THE BOCA CODE. i• FLUSH MOUNTED IN FINISHED AREAS AND WHERE INDICATED.SURFACE MOUNT ELSEWHERE. N. ALL TERMINALS,INCLUDING THOSE FOR CHANGING TAPS,MUST BE READILY ACCESSIBLE BY REMOVING A FRONT COVER PLATE. f, THE PROVISIONS OF STANDARDS,CODES,LAWS,ORDINANCES,ETC.,SHALL I CONSIDERED MINIMUM REQUIREMENTS.IN CASE OF e, SEISMIC RESTRAINTS ARE NOT REQUIRED FOR THE FOLLOWING: j. ALL CABINIETS STALL INCLUDE AMPLE CONCENTRIC KNOCKOUTS ON TOP,BOTTOM,SIDES,AND BACK. CO ULOW T BETWEEN THEIR PUBLISHED REQUIREMENTS,THE ARCHITECT/DESIGN PROFESSIONAL SHALL DETERMINE WHICH IS TO BE k. DOORS MUST BEPROVIDED FOR ALL PANELS.HEAVY CODE GAUGE STEEL AS REQUIRED TO MAINTAIN PANEL FACE FLAT, 0. TAPS SHALL HAVE A 5°/"FCAN AND 10°k FCBN FXCEEED HAND HIS DECISION SHALL BE BINDING.A E PRE REQUIREMENTS OF THIS SPECIFICATION OR THE DRAWINGS,WHICH e.a. CONDUIT IN MECHANICAL EQUIPMENT ROOM THAT IS LESS THAN MET INTERNAL DIAMETER. L DOORS SHIALL BE HINGED ON EITHER THE LEFT OR RIGHT AND EQUIPPED WITH A 110 DEGREE DOORSTOP OR A CONTINUOUS O.a. 2.5%STEPS ON ALL VOLTAGES 350 V AND ABOVE,15 TO 225KVA EXCEEED THE PUBLISHED REQUIREMENTS,SHALL TAKE PRECEDENCE OVER THEM. e.b. ALL OTHER ELECTRICAL CONDUIT LESS THAN 2-1(2"INTERNAL DIAMETER. g. NATI ONAL FIRE PROTECTION ASSOCIATION(NFPA)STANDARDS OF THE ISSUE IN EFFECT ON DATE OF THE INVITATION FOR BIDS e.c. ALL CONDUIT SUSPENDED BY INDIV►DUAL HANGERS 12"IN LENGTH OR LESS FROM THE TOP OF THE PIPE TO THE BOTTOM OF PIANO-TYPE HINGE WITH A MAXIMUM OPENING OF 160 DEGREES.DOORS SHALL BE DOOR IN DOOR TYPE. SHALLL FORM A PART OF THIS SPECIFICATION,UNLESS THEY CONFLICT WITH LOCAL CODES. THE STRUCTURAL SUPPORT FOR THE HANGER. m, THE CABIMET SHALL BE ELECTROSTATIC POWDER-COATED OVER A RUST INHIBITOR OR A BAKED ENAMEL FINISH.THE COLOR SHALL 0•b. 5%STEPSON ALL VOLTAGES BELOW 350 V,15 TO 225KVA h. ALL I MATERIALS FURNISHED AND ALL WORK INSTALLED SHALL.COMPLY WITH THE RULES OF LOCAL APPLICABLE CODES AND t SEISMICALLY SUPPORT ALL NON-ISOLATED FLOOR AND WALL MOUNTED EQUIPMENT,INCLUDING TRANSFORMERS,SWITCHGEAR, BE ANSI 61 I LIGHT GRAY. P. TRANSFORMERS SHALL HAVE PROVISIONS FOR BONDING NEUTRAL TO GROUND RECtOMMENDATIONS OF THE NATIONAL FIRE PROTECT/ON ASSOCIATION,WITH ALL REQUIREMENTS OF LOCAL UTILITY COMPANIES, EMERGENCY GENERATORS,ETC, n. PROVIDE CYLINDER LOCK.ALL PANELS KEYED ALIKE.PROVIDE FOUR(4)OF EACH PANEL KEY. Q. TRANSFORMERS VENTILATION SHALL NOT BE LOCATED IN WIRE ACCESS AREAS DEFINED ON DRAWINGS WITHi THE RECOMMENDATIONS OF THE FIRE INSURANCE RATING ORGANIZATION HAVING JURISDICTION,AND WITH THE g. ALL CEILING-MOUNTED LIGHTING FIXTURES AND DEVICES ARE TO BE INDEPENDENTLY HUNG AND CABLE BRACED UTILIZING S.R.TYPE o. WELDED AANGLE REST AT THE BOTTOM OF THE DOOR TO FACILITATE COVER INSTALLATION. J. TRANSFORMER ACCESS AREAS SHALL ALLOW FOR NEC BENDING RADIUS F LL VERNMENTAL DEPARTMENTS HAVING JURISDICTION. III CABLES. FIXTURE,PART OF LIGHTING GRIDS SHALL MEET LOCAL CODES FOR SUSPENSION AND BE FOUR-POINT INDEPENDENTLY p. DOORS OVIER 48"IN HEIGHT SHALL HAVE AUXILIARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO LOCK AND CATCH. REQUIREMENTS 0 A GO METAL BLANK FILLERS PLASTIC FOR RETROFITS i, AT THE COMPLETION OF THE WORK,THE CONTRACTOR SHALL SECURE AND DELIVER TO THE ARCHITECTfDESIGN PRCFES510NAL, CABLE BRACED TO DECK UNLESS A.T.C.CEILING MEETS SEISMIC ZONE II REQUIREMENTS. IF THIS IS MET,EARTHQUAKE CLIPS SHALL q• I )SHALL BE PROVIDED FOR EACH UNUSED CIRCUIT POSITION. K. TERMINALS SHALL BE SIZE TO HANDLE CABLES FOR THE FOLLOWING WIRE RANGE INDICATED ON THE CONTRACT DOCUMENTS. "CERTIFICATE OF APPROVAL"FROM THEVARIOUS LOCAL VILLAGE,TOWN,COUNTY,CITY,STATE BUREAUS,FIRE MARSHAL,FIRE SECURE FIXTURE TO T-BAR CONSTRUCTION. r, TERMINAL.LUGS•BOLTED TYPE,LABELED FOR EITHER COPPER OR ALUMINUM CONDUCTORS. L. THE TRANSFORMER ENCLOSURES SHALL BE VENTILATED AND BE FABRICATED OF HEAVY GAUGE,SHEET STEEL CONSTRUCTION. THE UNDERWRITERS,LOCAL BUILDING DEPARTMENT AND ALL DEPARTMENTS HAVING JURISDICTION. s. LOCATE MIAIN LUGS PROPERLY AT TOP OR BOTTOM,DEPENDING WHERE MAIN FEEDER ENTERS. ENTIRE ENCLOSURE SHALL BE FINISHED UTILIZING A CONTINUOUS PROCESS CONSISTING OF DEGREASING,CLEANING AND j. INCL.UDE IN THE WORK,WITHOUT EXTRA COST TO THE OWNER,ANY LABOR,MATERIALS,SERVICES,APPARATUS,DRAWINGS,(IN 2. ALTERATIONS 1. ELECTRICAL RATINGS PHOSPHATIZING,FOLLOWED 8Y ELECTROSTATIC DEPOSITION OF POLYMER POLYESTER POWDER COATING AND BAKING CYCLE TO ADDITION TO CONTRACT DRAWINGS AND DOCUMENTS)IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS,ORDINANCES,RULES AND A, PERFORM ALL WORK WHEN AND AS DIRECTED. SUBMIT SCHEDULE TO OWNER FOR ACCEPTANCE. a. ALL CIRCUIT BREAKERS SHALL BE FULLY-RATED UNLESS THE DRAWINGS SPECIFICALLY INDICATE SERIES RATED.WHEN SERIES REGGULATIONS,WHETHER OR NOT SHOWN ON DRAWINGS AND/OR SPECIFIED.(7)GIVE ALL NECESSARY NOTICES,OBTAIN ALL PERMITS B. REMOVE ALL EQUIPMENT SHOWN TO BE REMOVED. RATINGS ARE APPLIED WITH INTEGRAL OR REMOTE UPSTREAM DEVICES,A LABEL OR MANUAL SHALL BE PROVIDED.IT SHALL STATE PROVIDE UNIFORM COATING OF ALL EDGES AND SURFACES. THE COATING SHALL BE UL RECOGNIZED FOR OUTDOOR USE, THE AND)PAYALL GOVERNMENTAL TAXES,FEES,AND OTHER COSTS IN CONNECTION WITH THE WORK;FILE ALL NECESSARY PLANS, C. MAINTAIN CONTINUOUS SERVICE ON FEEDERS,CIRCUITS OR PARTIAL CIRCUITS,AND OUTLETS AFFECTED BY THIS WORK,EXCEPT THE CONDITIONS OF THE UL SERIES RATINGS INCLUDING: COATING COLOR SHALL BE ANSI 49. PREIPARE ALL DOCUMENTS,AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING JURISDICTION: WHERE OWNER GIVES WRITTEN PERMISSION FOR OUTAGE FOR SPECIFIED TIME.ALL WORK REQUIRING SHUT DOWN OF EXISTING a.a. SIZE AND TYPE OF UPSTREAM DEVICE LA. MINIMUM CLEARANCE FROM REAR AND SIDES%" OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION FOR THE WORK AND DELIVER TO THE ARCHITECT BEFORE REQUEST FOR SYSTEMS SHALL BE PERFORMED ON OVERTIME AT HOURS AS APPROVED BY THE OWNER AND AT NO ADDITIONAL COST TO THE OWNER. a.b. BRANCH DEVICES THAT CAN BE USED ACCEPTANCE AND FINAL PAYMENT FOR THE WORK. SUBMIT SCHEDULE OF REQUIRED OUTAGES TO THE OWNER FOR APPROVAL. PERFORM WORK IN A MANNER TO MINIMIZE SHUTDOWN a.c. UL SERIES SHORT-CIRCUIT RATING. L.B. UNITS 75KVA AND SMALLER SHALL HAVE KITS TO CONVERT TO WALL MOUNTED k. THE CONTRACTOR SHALL ESTABLISH,ENFORCE AND IMPLEMENT ALL SAFETY,HEALTH AND ENVIRONMENTAL PROTECTION TIME. b. WHERE IN DICATED,PROVIDE PANELBOARDS HAVING A'SERVICE ENTRANCE"TYPE UL LABEL WITH NEUTRALS FACTORY BONDED TO L.C. UNITS 150KVA AND SMALL SHALL HAVE PROVISIONS TO BE TRAPEZE MOUNTED MEASURES DURING PERFORMANCE OF THE WORK CONSISTENT WITH THE REQUIREMENTS OFTHE WILLIAMS-STEIGER FRAME Off ENCLOSURE• L.Q. ALL ENCLOSURES SHALL HAVE KIT TO CONVERT FROM TYPE 1 OR 2 TO TYPE 3R D. PROVIDE RECONNECTIONS AND TEMPORARY INSTALLATIONS AS REQUIRED;REMOVE ALL AT JOB COMPLETION. OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970(LATEST REVISION),OTHER RULES,LAWS,STATUTES,CODES,ORDINANCES, c. ALL UFACTUR R'S SHALL INCLUDE LABELS WITH FOLLOWING INFORMATION:"DANGER OF ELECTRICAL SHOCK"LABEL;UL LISTING; M. SOUND LEVELS SHALL BE WARRANTED BY THE MANUFACTURER NOT TO EXCEED THE FOLLO E. TAKE POSSESSION AND REMOVE FROM THE PREMISES ALL ABANDONED MATERIALS AND EQUIPMENT UNLESS SPECIFIED AS MANUFACTURER'S NAME;DATE OF MANUFACTURE;#OF PHASES;VOLTAGE RATING;CURRENT RAl1NG;SHORT-CIRCUIT RATING WING:15 TO 50KVA-39DB;51 T0112.5 KVA- REGULATIONSANDOTHERREQUIREMENTSOFANYANDALLGOVERNMENTALORQUASI-GOVERNMENTAL AUTHORITIES HAVING RETURNABLE TO THE OWNER;IN WHICH CASE,REMOVE WITHOUT DAMAGE ALL SUCH EQUIPMENT AND TURN OVERANODELIVERTO N. UNLESS OTHERWISE SPECIFIED SHALL BE EQUIPPED WITH PLASTIC DESIGNATION PLATE. 44DB;150KVA-47DB;151TO300KVA-49DB;301TO500KVA-54DB;501TO700KVA-56DB;701TO1000KVA.58DB 3.0 07.09.25 DESIGN MODIFICATIONS JURIISDICTION OVER THE WORK,THE PROJECT OR THE PROJECT SITE. 1. EQUIPMENT,FIXTURES,MATERIAL AND INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING OWNER AT LOCATION DESIGNATED BY THE OWNER ALL REQUIREMENTS OF GOVERNING AUTHORITIES SHALL BE COMPLIED WITHIN THE 0. CIRCUIT BREAKER DEVICES N. OPTIONAL ACCESSORIES-PROVIDE THE FOLLOWING WHERE INDICATED ON CONTRACT DRAWINGS AND AS APPLICABLE TO THE DEPARTMENT,THE SERVING UTILITY COMPANIES,THE NATIONAL ELECTRICAL CODE,NATIONAL ELECTRICAL SAFETY CODE,LIFE REMOVING AND DISPOSING OF ALL AND ANY MATERIALS ENCOUNTERED,INCLUDING BALLASTS,LAMPS,SMOKE DETECTORS,BATTERIES a. PLASTIC MIOLDED CASE.COMPLETELY SEALED ENCLOSURE.TOGGLE TYPE OPERATING HANDLE.TRIP AMPERE RATING AND ON/OFF PROJECT: 2.0 05.1 4.25 COMPLETE DES IG N SAFIETY CODE,STATE BUILDING CODE,OCCUPATIONAL SAFETY AND HEALTH ACT,AMERICANS WITH DISABILITIES ACT AND AND ANY OTHER MATERIALS WHICH REQUIRE RECYCLING OR SPECIAL HANDLING AND DISPOSAL. INDICATION CLEARLY AND VISIBLE. N.A. ALL MOUNTING BRACKETS FOR UNITS[UP TO 75KVA MAX.) APPPLICABLE NATIONAL,STATE AND LOCAL CODES,ORDINANCES AND REGULATIONS. F. CUT BACK TO FLOOR,WALL,OR CEILING AND PLUG ENDS OF CONCEALED CONDUITS MADE OBSOLETE BY ALTERATIONS TO PERMIT b. T HERMAL-MAGNETIC TRIP-FREE,TRIP-INDICATING,QUICK-MAKE,QUICK-BREAK,WITH INVERSE TIME DELAY CHARACTERISTICS. 1 .0 04,17.25 INITIAL DESIGN LAYOUT m. ALL ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH THE OWNER'S STANDARDS AND ELECTRICAL SYSTEMS REQUIREMENTS. REFINISHING SURFACES. REMOVE EXPOSED CONDUITS WIREWAYS,OUTLET BOXES,HANGERS AND DEVICES MADE OBSOLETE BY THIS SINGLE-HANDLE AND COMMON TRIPPING MULTIPOLE BREAKERS. N.B. CEILING MOUNTING BRACKETS FOR UNITS[UP TO 150KVA MAX.) n. ALL LOCAL FEES,PERMITS,AND SERVICES OF INSPECTION AUTHORITIES SHALL BE OBTAINED AND PAID FOR BY THIS CONTRACTOR• WORK UNLESS DES GNATED PEC F CALLY TO REMA N c. SILVER ALLOY CONTACTS WITH AUXILIARY ARC-QUENCHING DEVICES. 0. INSTALLATION;UNLESS OTHERWISE INDICATED,TRANSFORMERS SHALL BE FLOOR MOUNTED,INSTALL WALL-MOUNTING TRANSFORMERS REV DATE DESCRIPTION THE:CONTRACTOR SHALL COOPERATE FULLY WITH LOCAL COMPANIES WITH RESPECT TO THEIR SERVICES.CONTRACTOR SHALL I S I I I ' d. PANELBOARD MUSTSE OF THE TYPE WHICH WILL ACCEPT THE FIELD INSTALLATION OF SHUNT TRIP DEVICES OF 60 AMPERES OR LEVEL AND PLUMB WITH WALL BRACKETS FABRICATED BY TRANSFORMER MANUFACTURER,INSTALL FLOOR-MOUNTING TRANSFORMERS G• EXISTING CONCEALED CONDUITS NOT INTERFERING WITH THE WORK OF THIS OR ANY OTHER TRADE MAY REMAIN;HOWEVER,WIRING INCLLUDE IN HIS BID ANY COSTS TO BE INCURRED RELATIVE TO POWER SERVICE(PRIMARY AND/OR SECONDARY)AND TELEPHONE LESS ON THE BRANCH DEVICES, LEVEL ON CONCRETE BASES. CONSTRUCT CONCRETE BASES OF DIMENSIONS INDICATED,BUT NOT LESS THAN 4 INCHES LARGER IN SERIVICE. SHALL BE REMOVED FROM PANELBOARDS OR SOURCE OF POWER AND ENDS TAPED.NO UNUSED LIVE WIRING SHALL BE LEFT IN PLACE. e. CIRCUIT BREAKERS FOR POWER AND DISTRIBUTION PANELBOARDS SHALL HAVE A MINIMUM INTERRUPTING RATING OF 44,000 AMPS H. ALL EXISTING PANELS AFFECTED SHALL HAVE THEIR DIRECTORIES CORRECTED FOR NEW WORK,AND EXISTING REMAINING CIRCUITS RMS AT 2410 VOLTS AC. BOTH DIRECTIONS THAN SUPPORTED UNIT AND 4 INCHES HIGH AND ANCHOR TRANSFORMERS TO CONCRETE BASES ACCORDING TO C. EXAMIMAT10N OF EXISTING CONDITIONS VERIFIED.NEW TYPEWRITTEN DIRECTORIES SHALL BE PROVIDED• f. CIRCUIT 8 REAKERS FOR LIGHTING AND RECEPTACLE PANELBOARDS SHALL HAVE A MINIMUM INTERRUPTING RATING OF 22,000 AMPS MANUFACTURER'S WRITTEN INSTRUCTIONS,SEISMIC CODES AT PROJECT. a. VISIIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE SITE AND/OR PRESENT BUILDINGS AFFECTED BY THIS WORKSO AS TO RMS AT 24I0 VOLTS AC. P. GROUNDING;TRANSFORMERS SHALL BE GROUNDED IN ACCORDANCE WITH THE NEC ARTICLE 250. BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THE WORK,BEFORE 3. PHASING g• BOLTED TYPE TERMINALS U.L.LISTED FOR EITHER ALUMINUM OR COPPER 75 DEGREES C CABLES. Q• TESTS SUMMITT1NG PROPOSALS, CONTRACTOR SHALL CAREFULLY EXAMINE THE PRESENT L►GHTING AND RECEPTACLE INSTALLATION A. EXTEND AND RECONNECT EXISTING ELECTRIC SERVICES AS INDICATED ON THE DRAWINGS,IN TIME SEQUENCE AS DIRECTED BY h. PROVIDE MAIN BREAKERS IN PANELS,WHICH ARE FED(SERVED)FROM TRANSFORMERS UNLESS SEPARATE TRANSFORMER MET1 HODS WHICH ARE TO BE EXTENDED FOR THE NEW WORK• COORDINATED WITH THE OWNER. SECONDAIRY PROTECTION IS PROVIDED• Q.A. VISUAL AND MECHANICAL INSPECTION:INSPECT FOR PHYSICAL DAMAGE,MECHANICAL AND ELECTRICAL CONNECTIONS,CHECK b. SUBIMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR I. SHUNT TRIP BREAKERS SHALL BE SUPPLIED WITH 120 VOLT COILS.PROVIDE 120 VOLT CIRCUIT FROM NEAREST 120 VOLT PANEL TO TIGHTNESS OF ACCESSIBLE BOLTED JOINTS BY CALIBRATED TORQUE METHOD,CHECK FOR COLLECTION OF DIRT IN THE WINDINGS LABIOR,EQUIPMENT,OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED,WHICH COULD HAVE BEEN FORESEEN HAD 4. IDENTIFICATION OF EQUIPMENT AND COMPONENTS COIL.WHERE SHUNT TRIP BREAKERS ARE IN EMERGENCY PANELS PROVIDE EMERGENCY 120 VOLT SOURCE FOR SAME FROM AND COMPARE EQUIPMENT NAMEPLATE INFORMATION WITH LATEST SINGLE LINE DIAGRAM AND REPORT DISCREPANCIES. NEAREST 120 VOLT EMERGENCY PANEL. SUCH EXAMINATION BEEN MADE,WILL NOT BE RECOGNIZED. A. PROVIDE FIXED IDENTIFICATION OF ALL DISTRIBUTION EQUIPMENT(NAMEPLATES)AND CONDUCTORS. Q.B. INSULATION RESISTANCE(MEGGER)TEST WINDING-TO-WINDING AND W/vDING-TO-GROUND. B. UNLESS OTHERWISE NOTED,NAMEPLATES SHALL BE BLACK BAKELITE PLATES WITH WHITE ENGRAVED UPPER CASE LETTERS ENCLOSED j• PROVIDE LACKING DEVICE FOR DESIGNATED BREAKERS. Q.C. RECORD TRANSFORMER SECONDARY VOLTAGE AT EACH UNIT FOR AT LEAST 48 HOURS OF TYPICAL OCCUPANCY PERIOD. ADJUST D, TIME APVD MANNER OF EXECUTION OF WORK k, FOR HVAC EQUIPMENT PROVIDE UL LISTED"HACR"TYPE DEVICES. BY WHITE BORDER ON BEVELED EDGE. P. GROUND FAULT INTERRUPTERS TRANSFORMER TAPS TO PROVIDE OPTIMUM VOLTAGE CONDITIONS AT SECONDARY TERMINALS. OPTIMUM IS DEFINED AS NOT a. ALL WORK SHALL BE DONE AS EXPEDITIOUSLY AS POSSIBLE AND IN SUCH A MANNER AS NOT TO CAUSE INTERFERENCE OR C. ALL NAMEPLATES MUST BE ENGRAVED AND MUST BE SECURED WITH RIVETS,BRASS OR CADMIUM PLATE SCREWS.THE USE OF OYMO a. GROUND(FAULT INTERRUPTER BRANCH CIRCUIT BREAKERS SHALL BE AS INDICATED ON THE DRAWINGS.CB's SHALL BE CIRCUI EXCEEDING NAMEPLATE VOLTAGE PLUS 10 PERCENT AND NOT BEING LOWER THAN NAMEPLATE VOLTAGE MINUS 5 PERCENT. INTERRUPTION TO THE BUSINESS OF THE OWNER. SUBMIT SCHEDULE FOR REVIEW AND APPROVAL.THE CONTRACTOR SHALL NOT TYPE OR THE LIKE IS UNACCEPTABLE. T SUBMIT RECORDING AND TAP SETTINGS AS TEST RESULTS. OBSiTRUCT ENTRANCES OR PASSAGES ON THE OWNER'S PREMISES• INTERRUPTING WHICH WILL OPERATE MANUALLY FOR NORMAL SWITCHING FUNCTIONS AND AUTOMATICALLY UNDER OVERLOAD, PROJECT NAME b. TRAINSPORTATION OF MATERIAL INTO AND THROUGH THE BUILDING WILL BE SUBJECT TO REVIEW AND APPROVAL OF THE OWNER SHORT CI�RCUIT,AND 0.005 AMP LINE-TO-GROUND FAULT CONDITIONS.THE OPERATING MECHANISM SHALL BE ENTIRELY TRIP-FREE O.D. MANUFACTURER'S FIELD TECHNICIAN SHALL PROVIDE A CERTIFIED TEST REPORT. AND)MAY BE LIMITED TO RESTRICTED TIMES. 5. CONDUIT AND RACEWAYS SO THAT CONTACT CANNOT BE HELD CLOSED AGAINST AN ABNORMAL OVERCURRENT,SHORT CIRCUIT,OR GROUND FAULT R. NAMEPLATES;PROVIDE ENGRAVED NAMEPLATE AFFIXED AT FRONT OF THE TRANSFORMER.IT SHALL CONTAIN ALL NECESSARY c. THE:OWNER WILL MAKE AVAILABLE TO THE CONTRACTOR AN ELEVATOR FOR HANDLING MATERIALS,RUBBISH,ETC.AT SUCH TIMES A. ALL WIRING SHALL BE RUN IN CONDUIT.MINIMUM SIZE CONDUIT SHALL BE 3/4",EXCEPT AS OTHERWISE INDICATED• CONDITIOIN.THE DEVICE SHALL BE BOLT-ON TYPE AND SHALL BE INTERCHANGEABLE WITH STANDARD 1P CB UTILIZED IN THE ELECTRICAL CHARACTERISTICS AND RATING OF THE TRANSFER, WHEEN IT IS CONVENIENT TO THE OCCUPANTS OF THE BUILDING.THE CONTRACTOR SHALL PROTECT THE INTERIOR OF THE CAB B. CONDUIT SHALL BE MADE OF STANDARD RIGID PIPE,AND SHALL BE ALUMINUM WHERE PERMITTED BY CODE.WHERE ALUMINUM IS NOT PANELBOARD. AGAAINST DAMAGE AND PROVIDE LABOR TO HANDLE MATERIALS IN AND OUT OF THE ELEVATOR AND OUT OF THE BUILDING. PERMITTED BY CODE,USE RIGID STEEL OR IMC CONDUIT. Q. INSTALLATION END OF WRITTEN SPECIFICATION ELECTRIC VEHICLE d. ALL•MATERIALS TO BE REMOVED ARE TO BE LEGALLY DISPOSED OF,OFF SITE, EACH DAY EXCEPT WHERE OTHERWISE NOTED, C. ELECTRIC METALLIC TUBING(EMT)MAY BE USED IN DRY LOCATIONS FOR BRANCH CIRCUITING AND/OR IT DATA RACEWAYS, a. MOUNT ALL PANELS AT A MAXIMUM HEIGHT OF 6 FEET 6 INCHES TO TOP UNLESS OTHERWISE NOTED. EXTFREME CARE IS TO BE TAKEN TO AVOID SPILLAGE OF DEBRIS. D. TYPE AC(BX)OR MC WITH GREEN INSULATED GROUND WIRING MAY BE USED CONCEALED IN DRY LOCATIONS FOR BRANCH CIRCUIT b. WHERE FLUSHED MOUNTED,THE FIRE INTEGRITY OF THE WALL IN WHICH IT IS INSTALLED MUST BE MAINTAINED. CHARGING STATI O N e. THISS WORK IS TO BE PERFORMED TO PROTECT ADJOINING AREAS,EQUIPMENT, AND OCCUPANTS FROM DAMAGE AND HARM AND TO WORK ONLY WHERE PERMITTED BY CODE. c. NEATLY AIRRANGEBRANCH CIRCUIT WIRES AND TIE TOGETHER IN EACH GUTTER WITH THOMAS&BETTS NYLON"TY-RAPS",OR PRO)DUCE MINIMUM DISTURBANCE TO OPERATIONS.PROVIDE ALL PROTECTIVE METHODS AND SCHEDULE WORK WITH OWNER. E. FOR UNDERGROUND ELECTRICAL INSTALLATIONS,USE FIBERGLASS(RTRC)CONDUIT AND/OR PVC SCHEDULE 80 WITH LISTED FITTINGS APPROVEID EQUALAT MINIMUM 4 INCH INTERVALS. I NSTALLA 0 t ANY(CONSTRUCTION TO BE LEFT 1N PLACE THAT IS WEAKENED OR DAMAGED SHALL BE RESTORED TO THE CONDITION WHICH AND CONNECTIONS.THESE SHALL BE CHANGED TO RMC WHILE TRANSITIONING FROM UNDERGROUND TO ABOVE GRADE• THE d. PLUG ALL KNOCKOUTS REMOVED AND NOT UTILIZED. TI N AT EXISSTED PRIOR TO SUCH DAMAGE e. PROVIDE(NAMEPLATE AND FILL OUT PANEL DIRECTORY.FOR REMODEL WORK OR CHANGES,TRACE CIRCUITS TO DETERMINE LOADS CONDUITS SHALL BE BURIED DEPTH EXCEEDING NEC REQUIREMENTS,UNLESS OTHERWISE INDICATED ON DRAWINGS. g. COMISTRUCTION THAT IS TO BE REPLACED AFTER REMOVAL WORK SHALL BE REPLACED WITH CONSTRUCTION OF EQUAL STRENGTH F. WIRING FOR LIFE SAFETY INSTALLATION,INCLUDING EMERGENCY LIGHTING,EMERGENCY COMMUNICATION,ALARMS,etc. SHALL BE AND PROVIDE NEW UPDATED DIRECTORY. 6400 MAIN RD AND)DESIGN. WIRE IN RIGID METAL CONDUIT. R. f BALANG ID ROUNDING AND BONDING JUMPERS PER SECTION 16140 AND AS INDICATED ON THE DRAWINGS. MATTITUCK, NY 11952 E. GUARAWTEE G. MAKE FINAL CONNECTION FROM MOTOR STARTING SWITCHES TO MOTOR BY MEANS OF CONDUCTORS IN FLEXIBLE STEEL CONDUIT.USE a. ALL BRANiCH CIRCUITS SHALL BE BALANCED AT THEIR RESPECTIVE PANEL TO WITHIN 10 PERCENT FULL LOAD APPLIED, a. ALL.WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THE "SEALTITE"IN WET OR DAMP LOCATIONS ONLY. 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 INSTEALLATION AND ANY PORTIONS OF THE WORK WHICH DEVELOP DEFECTS DURING THAT TIME SHALL BE REPLACED OR REPAIRED H. HANGERS,SUPPORTS AND SLEEVES SHALL BE AS ACCEPTABLE TO GOVERN CODES.SUPPORT RISER CONDUIT AT EACH FLOOR,AND ALL 7. LIGHTING AND POVVER MATERIALS IN A i MANNER SATISFACTORY TO THE OWNER. OTHER CONDUIT ON EACH SIDE OF BENDS AND NOT GREATER THAN 8'-O"ON CENTERS. DO NOT SUPPORT COMMUNICATIONS,SIGNALING A. FURNISH AND/INSTALL ALL BOXES,FITTINGS,DEVICES,RACEWAYS,CONDUCTORS,CONNECTIONS,MOUNTING ACCESSORIES,ADAPTERS b. ALL,MANUFACTURER'S WARRANTIES FOR EQUIPMENT EXTENDING BEYOND THE GUARANTEE PERIOD SHALL BE TURNED OVER TO THE AND SIMILAR TYPE WIRING FROM CONDU►TS• AND ALL OTHIER MATERIALS,EQUIPMENT AND LABOR NECESSARY FOR A COMPLETE ELECTRICAL INSTALLATION. OWINNER• 1. COORDINATE CONDUIT RUNS WITH EXISTING AND NEW WORK.CONCEAL ALL CONDUIT AND OUTLET BOXES IN FINISHED AREAS UNLESS B, INSTALL ELECTRIC OUTLETS VERTICALLY UNLESS NOTED TO THE CONTRARY AT HEIGHTS AS NOTED. THOSE LOCATED ON INTERIOR c. REPPLACE OR REPAIR TO THE SATISFACTION OF THE OWNER ANY AND ALL DAMAGE DONE TO THE BUILDING OR ITS CONTENTS OR TO NOTED OTHERWISE• COLUMNS SHALL BE CENTERED LATERALLY. SHEET TITLE THE:WORK OF OTHER TRADES IN CONSEQUENCE OF WORK PERFORMED IN FULFILLING GUARANTEE. J. RUN CONDUITS CLEAR OF SHAFTS,OPENINGS,CABLE SLOTS AND TELEPHONE RACKS.DO NOT SUPPORT CONDUITS OR RACEWAYS C. MOUNTING HEIGHT OF CONVENIENCE RECEPTACLES SHALL BE 20"A.F.F.,UNLESS OTHERWISE NOTED• d. THIS ARTICLE IS GENERAL IN NATURE AND WILL NOT WAIVE STIPULATIONS OF OTHER CLAIMS THAT SPECIFY GUARANTEE PERIODS IN FROM TELEPHONE FRAMES,CABLE RACKS OR SUPERSTRUCTURES. D. USE CAST BOXES FOR EXPOSED WORK,AND WHERE INSTALLED FLUSH IN FLOORS.ALL OTHER OUTLET BOXES SHALL BE SHEET STEEL E-ZOO EXCCESS OF ONE(1)YEAR.IN THE EVENT DEFAULT ON THIS GUARANTEE,THE OWNER MAY HAVE SUCH WORK DONE AS REQUIRED& CHAARGE THE COST TO THE CONTRACTOR. K. TERMINATE EACH CONDUIT WITH TWO LOCKNUTS,ONE INSIDE AND ONE OUTSIDE AND A BUSHING.USE ALUMINUM LOCKNUTS FOR AND GALVANIIZED.FLOOR BOXES SHALL BE ADJUSTABLE TYPE. e. THE:DATE OF ACCEPTANCE SHALL BE THE DATE OF FINAL PAYMENT BY THE OWNER OR NOTICE OF ACCEPTANCE BY THE OWNER ALUMINUM CONDUIT,AND MALLEABLE IRON OR GALVANIZED OR CADMIUM PLATED STEEL FOR STEEL CONDUITS,BUSHINGS SHALL BE E. ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE.DECORATOR TYPE SHALL BE PROVIDED IN FINISHED AREAS.DECORATOR TYPE WHIICHEVER IS EARLIER INSULATED PLASTIC TYPE,RATED AT NOT LESS THAN 150"C,T&B SERIES 510 OR AS ACCEPTABLE.WHERE CONDUITS LARGER THAN 1" SHALL BE PROVIDED WITH MATCHING PLATES. HEAVY DUTY DEVICES SHALL CONFORM TO NEMA STANDARD WD-1, GENERAL NOTES SIZE ARE TERMINATED,LOCKNUTS SHALL BE THE BONDING TYPE T&B SERIES 106,OR AS ACCEPTABLE.IF ALUMINUM BONDING F. ALL LOCAL SVNITCHES EXCEPT AS OTHERWISE INDICATED SHALL BE TOGGLE TYPE 20 AMPERE,120-277V CAPACITY WITH FULLY F. CUTTINIG AND PATCHING LOCKNUTS ARE NOT AVAILABLE,USE A BONDING WEDGE IN ADDITION UNDER THE INTERIOR ALUMINUM LOCKNUT. ENCLOSED COMPOSITION CASES.SWITCHES SHALL BE LEVITON 5621-2 FOR DECORATOR TYPE AND HUBBELL HBL 1221 FOR COMMERCIAL a. ALL CUTTING AND PATCHING SHALL BE DONE UNDER ANOTHER SECTION.FURNISH THE SIZES AND LOCATIONS OF ALL CHASES AND L. WHERE CONDUITS LARGER THAN 1"SIZE TERMINATE IN ECCENTRIC OR CONCENTRIC KNOCKOUTS AND WHERE ALL OF THE KNOCKOUT TYPE,OR AS]DESIGNATED BY ARCHITECT. OPEENINGS REQUIRED FOR THE INSTALLATION FOR THIS WORK BEFORE THE WALLS,FLOORS AND PARTITIONS ARE BUILT, RINGS HAVE NOT BEEN REMOVED,INSULATED GROUNDED BUSHINGS SHALL BE USED.INSULATED GROUNDED BUSHINGS SHALL BE CAST, G. ALL RECEPTACLES SHALL BE 20 AMP,2-POLE,3-WIRE,NEMA 5-20R,UNLESS SHOWN OTHERWISE ON DRAWINGS.DECORATOR TYPE SHALL b. PRO)VIDE THE LABOR AND MATERIALS FOR ALL WORK INCLUDED UNDER THE CONTRACT OR SUBCONTRACT IN AMPLE TIME AND THREADED TYPE EQUIPPED W►TH A LUG FOR GROUNDING. UPPER EDGE SHALL HAVE A NYLON RING OR A BAKELITE RING WHICH IS BE HUBBELL STYLE LINE HBL 2162;COMMERCIAL TYPE SHALL BE HUBBELL HBL 5462 OR AS APPROVED ACCEPTABLE• SEAL SUFFICIENT QUANTITIES SO THAT ALL OF THE WORK OF THE CONTRACT OR SUBCONTRACT MAY BE INSTALLED IN PROPER MOLDED INTO THE BUSHING. SIZE GROUND LUG TO TAKE CONDUCTOR SIZED ACCORDING TO CODE WITH A MINIMUM SIZE OF NO.12. H. RECEPTACLES IN UNDERFLOOR BOXES SHALL BE INSTALLED AND PRE-WIRED AT THE FACTORY IN ACCORDANCE WITH THE EXISTING PROJECT N0:LAUREL LINKS SEQUENCE TO AVOID UNNECESSARY CUTTING OF THE FLOORS AND WALLS. SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH 1, 0 C C)� CHECKED BY: cc , , . Lp tl �l j�y.,.,—v ,. :�I C,`f W"d'l�GB�"� Z7 ✓1 O7JA:�°S yz� \cr., r� ______ I i CLIENT,PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD W W W W W W W W W W W W W W W W W W LAUREL, NY 11948 AKA 6400 MAIN RD v, v, 14, v v v v v �' v' v v v' �' �— — v' v v v, v v v v �' �, v v v v v v v v MATTITUCK, NY 11952 .l- � � vi � � � � v/ � � �- `L v/ v/ � v' � � � � yr �/ � v/ � v � yr Ji � —�l, � � `1' � v/ v' � v/ � �! � � vi � v v/ �1, L �L � �• � � `L v. W v v, y v v v v' v' v, v' v, v, v v v v v, v, � v, \1/ q, v v v I v v v v v v v' v L v' v v v, v' w v v v DESIGN CONSULTANT v v v y' v v v, y v �' v v V• v �' v'i v v v A 1. v v v L v v v' v v \,M v y vi v/ v/ yr yr Vi `Ji vi v� v' v/ .� v/ Vi �1' yr I v/ v/ .y •�, •t, .1, .1, .1, .1, 't, .1, .1, NEW 400A 120/208V 304W METER v v v v l ( v v L v v, v �, �' L v. v v, v' y v v v v v L I ✓ 1' L mil' v/ \1/ v' v/ \�, q/ .li \t/ . .l .L WC� Lh L .V � � .V v/ � .V vi .V .V v' v' � .t/ Q 1;(f �°' � •.li yr Q "�� �p .1/ � vi v' vi � •U I � v' v, v/ v' � vi .y �L � v/ �' vi v' v. v/ vi � v/ �� � vi q 6r V v' V v �tl S �Lr 7 l L L �U"D ° a L v' v . e• l'I v v L Q v t L v v v' v' vi v. \V \L1 vi q, �1 v. v. v. .li vi �!• .c°� , vi .V `L �l .j. Q.L � ����'�L���a � .V v• � Q��n, �9 p �. �l, � .V .L/ � o� � I `1 � '/` � v/ �, � Ji �, � � � vi � Ji .L � Ji � v' � J � � a y' �' v I NEW 300A �' �' �' �. .1, .L v, � v,a �Q o �. 12 0/2 0 8 V 3 04 W � .L v, 6a9 � CONTRACTOR or VENDOR 41 QP° v J �z, fld � o ° EV PANEL W/ v a Q 30OA MCB �' �' Wood ll ® QW a s \1 \L q v �vVn � j a f p L oan o Q �eQ v' \1/ vi v w v v v v y v v w f J ( /�•l!/l'I!f/%l!/ (_/l•/�. W NEW VEGETATION TO 9 F L ✓ L L l' v L L L L L L L L L L L L v 3UU� OBSCURE EQUIPMENT L ° 0 L L \L vi � 1 I vi � L v v �' v L � a 103 School St, �OA� _,�'a4p a vi v� � (��`(r#, �o �L � �l. y, �, .i. .i. .i. .i, v �L �L .L v' �L �L �L `li �L v� v. .L `L �L �1 IUJp BRICK WALKWAY Lindenhurst, NY 11757 � `1' ° � � � o^ � d ts� �°o �L �, �D S�i,�L=' � L �, �L .L �L `L �L v' �L �l, �L �L � �L �1 v v� �L �L �L �' �• v• � �L v� `,1' vi vi .L �a �° ✓�? � v/ � ��1, �''J� C� fl� v. I .L .L .� �' �l, v. � .V .V � � v/ v/ v/ j a b q I LEGAL NOTES: y �� fl4Q v � � W "It is a violation of the state education law for any person, 4/ q' � � v' � � � 9 ��� (tea&�a I � �' �' L unless he or she is acting under the direction of a Ion this drawing and/or in s alter n anyway.wolf P g anyway, 8. ° b C1 9 / P a v v• v v' v, v v � v b L L v v v v v v v v v any such item is altered, the altering engineer shall affix to the item his or her seal and the notation "altered by" followed by his or her signature and the date of such ° b a alteration, and a specific description of the alteration." ����� a � � � v,� � ��o � ��p �� � � v' � � � I � � � � � � v � � • An errors and omissions in the drawing are to be P y g checked by the general contractor and relayed to the v' v v 4pp L v v L ,y I v v y J L architect/EOR a fl • Do not scale drawings U° I All work shall comply with the local building code(s) o/U and with requirements of loco! AHJ v' v�q �! p v o�° L v I L KEY PLAN: � d � U ° q b q d v Q G t��p�apP y, q �J�`S a �' � .t' `.I' \l y �. � v/ v' � � v/ � i �, .L 9 �.,(f��•,�,2,�(`J� � }WSJ v' a L ,4-o� EV CHARGER "All & 11611 �L �' o `�'� �' �L v/ yr y 3' �L �L yr � � v' �• � — � _ ❑ � � Q 3 � � ��tS� � v. �L •L .l� vi vi .L �l, �I, vi vi v' v, .1, v, �l, I vi � ®.� vi EV CHARGER "C" & "D" EV CHARGER E & F `1' J� Ji �- � � "Ell 11 11 I .L v 1' L vi L I If 3.0 07.09.25 DESIGN MODIFICATIONS 2.0 05.14.25 COMPLETE DESIGN vi v/ yr vi .V � v/ � v. v/ yr v' v/ � v. •L �l' .li � 'L \L � EV CHARGER "G" & "H" + ®,�, 1 .0 04.17.25 INITIAL DESIGN LAYOUT REV DATE DESCRIPTION L `L �L Ji v' � v/ `L `L• � yr � y' � �" �a v � v/ � �' � v' � 9 � L v v v � v/ �' � � yr v/ � � �l' � � v/ yr v, � � � � � � �1, v, yr �'✓ � b .L (,� v v, v, v v L v. v �' v' L v, v v' v, v, v, \L v, v PROJECT NAME ELECTRIC VEHICLE CHARGING STATION �' v/ � ���l/' 1...,��Q `L � .L .L � J, � �L .L �L �✓ v/ �l' v/ .L v, .L v, v, �l• � �� .L v. v, � �1' `1' .L .L _ INSTALLATION AT v v v v �' v �1°I� MATTIT400CK, NY MAIN AKA L v v 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 v• Ji Ji � � � v/ �' v/ � �L vi � yr � vi � �l, J� � v/ v/ Ji � v/ v' vi � � �L v/ � SHEET TITLE E-300 SATELLITE VIEW SEAL PROJECT NO:LAUREL LINKS SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH CHECKED BY: v/ vi v 1L Mn n C j 0764�'� t, I — I CLIENT, PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA + 6400 MAIN RD + MATTITUCK, NY 11952 I I DESIGN CONSULTANT: I I \� I I I I EV PARKING ONLY SIGN CONTRACTOR or VENDOR: I PROTECTIVE BOLLARD Wo O _hollow I EVC "A" � 103 School St, I Lindenhurst, NY 11757 I Z, Q0 S I ° \ LEGAL NOTE "It is a violation of the state education law for any person, unless he or she is acting under the direction of a — — — — — — — — — — — — — — — licensed professional engineer to alter an item in anyway, I on this drawing and/or in this specification in anyway. If any such item is altered, the altering engineer shall affix to O the item his or her seal and the notation "altered by" \ I / followed by his or her signature and the date of such V/ alteration, and a specific description of the alteration." Zr 1 ° • Any errors and omissions in the drawing are to be i w<z ° ° checked by the general contractor and relayed to the I architect/EOR • Do not scale drawings ���—O�� • All work sholll comply with the local building code(s) EVC BII and with requirements of local AHJ + KEY PLAN: I EVC "C'i Z o } o �Qo I U + � O - - - - - - - - - - - - - - - - - - I I—I o I W z z, { o �0 9'-0" TYP I EVC "D" I `� EXI TING LIGHTING I 18'-0" TYP EVC "E" z I 3.0 07.09.25 DESIGN MODIFICATIONS 6z 2.0 05.14.25 COMPLETE DESIGN I ° _° 1 .0 04.17.25 INITIAL DESIGN LAYOUT I U I REV DATE DESCRIPTION O I I-- - - — — — — — — — — — — — — — — — I I z + o �Qo / 3a PROJECT NAME I I EVC "F" + b ELECTRIC VEHICLE I CHARGING STATION EVC "G"+ z INSTALLATION AT II a° MATTITUCK NY 1195D2 AKA U 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 I I-- - — — — — — — — — — — — — — — — SHEET TITLE O E-301 U ° w z SITE PLAN a =o U SEAL PROJECT NO:LAUREL LINKS rs SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH C 11 H 11 ;ti CHECKED BY: j en to �1 rr'"rj��r CLIENT,PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA 6400 MAIN RD EXISTINJG UTILITY POLE •UTILITY ELECTRICAL SYMBOLS MATTITUCK, NY 952 PROVIDEm CONNECTION - POLE#356 DESIGN CONSULTANT: NEW 120/208V - - - - - - - - - - — - - - — — �/ 4 METER W NEW E 20 208V XMFR 300A 300A MCB 304W fl W/ 300A MCB I I FUSE 1 60A 60A 60A 60A 60A 60A 60A 60A { LOCK CONTRACTOR or VENDOR: I LOCK LOCK LOCK LOCK (LOCK LOCK LOCK I ABLE ABLE ABLE ABLE ABLE ABLE ABLE ABLE BREAKER A4Woodhollow SINGLE POLE I I BREAKER I I DUAL POLE — — — — — — — — — — — — — — — — — � 103 School St, BREAKER Lindenhurst, NY 11757 Al A A37 7 7 TRIPLE POLE TY P. LEGAL NOTES: II I I I I I SWITCH "It is a violation of the state education law for any person, 0- unless he or she is acting under the direction of a licensed professional engineer to alter on item in anyway, an this drawing and in this specification in anyway. If LL L �JI any such item is altered, the altering engineer shah affix to the item his or her seal and the notation "altered by" followed by his or her signature and the date of such EVCS "All EVCS EVCS 111C11 EVCS "T alteration, and a specific description of the alteration." V �7 f'1 V G� V L7 V • Any errors and omissions in the drawing are to be checked by the general contractor and relayed to the F F ' 7 F architect/EOR • Do not scale drawings • All work shall comply with the local building code(s) I I I I ( I and with requirements of local AHJ KEY PLAN: L L I L L EVCS "E" EVCS T" EVCS 11G11 EVCS 11H11 "EV PANEL" SCHEDULE VOLTAGE: 120/208V PHASE: 3 WIRE: 4 LOCATION: EXTERIOR MAIN RATING: 300A NEMA MIN kAIC: 14 MB 300A MTG: SURFACE 3R FLUSH REMARKS: Eaton or SquareD or APPROVED EQUAL COMMERCIAL GRADE PANEL Circuit DESCRIPTION C.B. VA VA C.B. DESCRIPTION Circuit No. No. 60A 60A 1 EV CHARGER "A" LOCK 4992 4992 LOCK EV CHARGER "C" 2 ABLE ABLE 3.0 07.09.25 DESIGN MODIFICATIONS (2) #6 THWN-2 2.0 05,14,25 COMPLETE DESIGN 3 (2) #6 THWN-2 CU - (1) 4992 4992 CU - (1) #10 EGC 4 1 .0 04.17.25 INITIAL DESIGN LAYOUT #10 EGC TH W N-2 CU THWN-2 CU REV DATE DESCRIPTION LOAD SUMMARY EVCS LOAD: 79.872KVA 60A 60A 5 EV CHARGER 11B" LOCK 4992 4992 LOCK EV CHARGER „D11 6 SYSTEM VOLTAGE: 120/208V ABLE ABLE TOTAL EVCS LOAD: KVA*1 .25 = 99.84KVA PER NEC ARTICLE 625.40 (2) #6 THWN-2 CU - (1) (2) #6 THWN-2 7 #10 EGC THWN-2 CU 4992 4992 CU - (1) #10 EGC 8 PROJECT NAME CONDUIT & WIRE SCHEDULE PER 310. 16, 250.667 250. 122, 358.30 THWN-2 CU FROM TO CONFIGURATION ELECTRIC VEHICLE 60A 60A CHARGING STATION NEW 400A 120/208V 304W (4) 500KCMIL THWN-2 AL 9 EV CHARGER "E" LOCK 4992 4992 LOCK EV CHARGER 1711 10 INSTALLATION AT Al UTILITY POLE METER QUADRUPLEX URD DIRECT ABLE ABLE 6400 MAIN RD BURIAL CABLE MATTITUCK, NY 11952 AKA (2) #6 THWN-2 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 (3) 3i0 THWN-2 CU - (1) #6 EGC (2) #6 THWN-2 CU - (1} •� A NEW 400A 120/208V 304W METER NEW 300A 120/208V 304W EV' THWN-2 CU IN 2" SCH 40 PVC 11 #10 EGC THWN-2 CU 4992 4992 CU - (1) #10 EGC 12 PANEL W/ 300A MCB RNMC THWN-2 CU SHEETTIT'LE E-400 8 SETS OF (2) #6 THWN-2 CU - 60A 60A NEW 300A 120/208V 304W EV PANEL EV CHARGERS (1) #10 EGC THWN-2 CU IN 1 A3 4" 13 EV CHARGER "G11 LOCK 4992 4992 LOCK EV CHARGER "H" 14 ELECTRICAL PLAN W/ 300A MCB ABLE ABLE SCH 40 PVC RNMC SEAL PROJECT NO:LAUREL LINKS (2) #6 THWN-2 SIGN AND SEAL SCALE:AS NOTED NEW 300A 120/208V 304W EV PANEL GROUND ELECTRODE SERVICE (2) #6 BARE CU TO (2) GROUND (2) #6 THWN-2 CU - (1) DRAWN BY: NH 15 4992 4992 CU - (1) #10 EGC 16 a � m�.. W/ 300A MCB AND CONDUCTOR RODS >6' APART #10 EGC THWN-2 CU CHECKED BY: THWN-2 CUCIO "v w 0 . CLIENT, PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA 6400 MAIN RD Model Number Connector Type Dimensions (H* * D) MATTITUCK, NY 11952 Maxi US AC W 12-L-- G SAE J`I 7 7 2 1 i� 7" X " ,(3 3 5 x 187 x 85 m m) DESIGN CONSULTANT. Weight Input cord Warranty 14 .8 lbs. ( .7 kg) Hardwired only 3 years Charging Cable Length Connectivity User authentication CONTRACTOR or VENDOR 25 ft. (7.5 m) 4G, BluetoOthA Wi-Fi, Ethernet, RB 5 App, ALItOta rt, RF I D card Woodhollow C J�il// !7 Advanced Feature Output Rating Input Rating Adaptive Load Management (ALM); Dynamic Load Balancing (DLB) Maximum 12 kW (2 0 VAC @ 50 A model) 208/2. 0 VACO 60 Hz, single phase ' 10 A, 24 A, 32 AI 40 A, 48 A, 50 103 School St, A Lindenhurst, NY 11757 LEGAL NOTES: It is a violation of the state education low for any person, r '� NOperatingTemperature unless he or she is acting under the direction of a Mounting licensed professional engineer to alter an item in anyway, on this drawing and/or in this specification in anyway. If 0vercurr en lL, OVerv0lt undervolt, integrated surge r0tec41 anyLion -40 t0131 �f](" (`�,0 tmay 55 OC) floor u d the such item is altered, the altering engineer shall affix to k.J"lt' t,AI t A1' � r I '�,{ � � � 1 � 4 �' �.J1. J— �,J l51 Wall-mounted �r "I (00,1'" 4A���� � ��'4.i��t�l the item his or her seal and the notation "altered by" followed by his or her signature and the date of such alteration, and a specific description of the alteration." • Any errors and omissions in the drawing are to be checked by the general contractor and relayed to the orchitect/EOR • Do not scale drawings 01-12.611 I 1 4.3 f1 • All work shall comply with the local building code(s) —►{I and with requirements of focal AHJ KEY PLAN 01-711 01-311 AUTEL 0 0 0 0 0 3.0 07.09.25 DESIGN MODIFICATIONS 2.0 05.14.25 COMPLETE DESIGN 0'-107.2" 1 .0 04,17.25 INITIAL DESIGN LAYOUT 0'-104" REV DATE DESCRIPTION 0'-3711 PROJECT NAME Q ELECTRIC VEHICLE CHARGING STATION INSTALLATION AT 6400 MAIN RD MATTITUCK, NY 11952 AKA 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 SHEET TITLE E-500 0'-7,9" EV CHARGER DETAIL AUTELCABLE AUTEL SEAL PROJECT NO:LAUREL LINKS SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH MANAGER PEDESTAL 8i CHECKED BY: I CLIENT,PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 AKA 6400 MAIN RD [H'�3"T MAY INCREZSZ_ MATTITUCK, NY 11952 _RUSr4 1 21 ,52 MULTIPLES Or flArED CUPPINT 6 1152) 70 12- [30-51 to [547] k (lel lt. t-1 Lu 3.00' 2.516 15-00 VFYl­1 ).t7 TO Stjpp,-)RT (114 f" [11;21 INCPLVEN's) at. K rw tit fs.44,i weir 17 70P OR BOTTOM GUTTER [76] 81 6CX WHII-E VCUNT N3 20.12 DESIGN CONSULTANT: P EXTL%SI'jNS ARC SPL`C�1"IED, v i mi Ty (2) cr mbq fro r 04 i r k M 1 Ur *F P""4r- W" 1*1W ro I"&W_rW�. W" P_rA d%&_I.1 Off*N.W.'Foo-P U-0^0 ow rw r-ff- k t4 15,00 H+.12 02".- k(I JANA j?5 ]!%2 Aer Va 10W vim be-dipir ormw oc'm+v-frwbl ry -p! !A LAI%C 1 IS ��.--Rrr-�11 FLUSH- A (4) H d',7 130X VOUNI W; Tr- .1 nv­-1.1-4,.-d,,l r. Q�7 Cr I C,0 HOLES (4) 42 DIA [ 1 #.. J jAAA .25 TYPICAL FRONT 20.00 [5 0 IF D vinil­,i mAy irA:pr 1% DEF"ll iNI'FIEA�-,ES TO 8,75' [222 F D9 E14C,�_OSURZ IS 5�2ECIFIED. POOR IHINC-FS - �s ! ( r i j '„ ( 3 �N--_ � �„�t je 'r � _�_ _ 1 _ __��_._-..___-____,_._._ _. CONTRACTOR or VENDOR- IF t r[F7 A,14DI(1747� P.CHT C, JITTFR -e - &M Awrn ve, PLrf.� 3L TYPICAL MOUNTING OF EYVEN'SION-Sa ARE SPECIFIED. TYPICAL BOX tk A Ln Carr TYPICAL BCX WITH INTERIOR S107 VIEW 00(8), 100(B)-VH, AND QH(8) 7 4 V" Cps- 01 or r"b-1 BRANCH CIRCUIT BREAKERS e.C11) Pee w.# WoodhoRow L 73. r Ye � An',AL": TV- '114) INCHES C0%CEt41R!;C`K0. CCNr-r'4TP,C YO. 01M[NS'0 4. 1-112.•7­�ZI(1-114. 1-t/7, 2 4- U"'AA-V WAN LLV� hfJWf4_FR OF H A V 103 School St, 2, 2-112, 3) 2-1/2, 3, 3-t/2) AV.-JIMill W 0' T_ Is CONCE1`41RIC K C0t1:[N_IR.J', KG CMCu 7', 14 0- AN Vtq .3) 4 A. All Lindenhurst, NY 11757 0 INDWALL WITH KNOCK UTS VIXAIM.19 AND W11- &OCA r---nl� CNE E-1`10 WA-LL OF STAr4'_`A:;D 5.7t" [146] CEEP. C I" r r 20" [505] WDE EOX HAS KNOCKOUTS, I.jE CMIFIR R�ANK, 4, 41 -W 4,1., Y rij i� E '?ot 14# iwYL LEGAL NOTES: IRGTH FNO-AALLS HWE ;eN-XKCUTS 1% VHXX,�E ROX17S. L WttN 'qrt- P-D!H END PALLS AP:_7 ELANK J1 ALL OTHER ENCLOSURES. 33 A- 4: !it,. It is a violation of the state education low for any person, A*0A W11- (A-) M K-ML 4 unless he or she is acting under the direction of a REFER 10, 111 PANELBOAROIS CA71ALOO MR f,7 JAAA iff 011,6111 .1"j tr0A WT4 (4) ftlrl VNJ-, 64 E-14 Ilece, Lt. 11`�41;ONJN* Llx-;�o AN licensed professional engineer to alter an item in anyway, INFORM-%TIGN NFUIP'k 114E LX1 CNI RVh+e0j%A LIN,to!,I n this drawing and/or in this specification in anyway. If �Dd 74-�-.I.�, P� T:I- 0 144. e�KIA W 1W any such item is altered, the altering engineer shall affix to F3 I rOP TYPE 3R APrL104TI-:)%S V-31C !tdJI CCi1,.1j1jNCT CN WI-11 Fff1D_Tf.&!J LLr;S rahWe& r A* the item his or her seal and the notation "altered by" X�wt_ PBA711 1 OR P2ACMINP '5. followed by his or her signature and the date of such NQ PANFLJ30ARDS KFET THE APPLICA91-E REQUIREVEN171S OF '4fM/&W VIT'l alteration, and a specific description of the alteration." w-,j-, nil 0- raiur U1, ANUD CSA. !�%j,)-Fffr pprm:M *6 1. j4- 7: wAro.-irlmr 0 Any errors and omissions in the drawing are to be - -L checked by the general contractor and reloyed to the COD~ GAXGF- GALVANIZED STEEL F'A 74 ­0 to of architect/EOR SM-1 Ur efliAwt It'S b FRCINT: r,,-RAY RAVr*D EN-WrL CVE7P CIFAN77, Q, !or, 1 P4 R Q.'<IDE D1W • Do not scale drawings 3.1 4 A" fIq 7,7 V -CC-:, Zoo rf,00 131 74 All work shall comply with the local building code(s) 77l Pl-qCSPHATIZED STELL FRONT IS VENILD AND oA 0. U. LL 1ACOUNTS TO FUMSURE WITH SCRFIAS. DCOP. H111_F13 and with requirements of local AHJ APRE CONCEALED. ,a Iff-WAISFE F*rHr &V 12* [NY51, r% VENTE3 I`Y�PF 3P EV-%C�-UHS, A,11­2 F cf tma AN P,;nu_vrL%rrr Tyrr ip, 4,/411, % 17 F%Clasuw s I, - L -K: rLXSH LOCK NVIT" FLP-TED STEEL E5CLI-C1­!ECo4. 0 A, (T1&4r`Dl7V,?r)4 rTL LUK;`- 1WQ1A'W �41710141` W CIZ KEY PLAN: (5*H7:, 9% LV,i IN-PLAA I.ISR-251 KEY, PANELFOAD5 W1711 175+ 0()��olwl) 4L^:Hlf eY 12' [.11 0�:") OIRCUIT BREAKERS HAYS 3 PCINT LATCH TRW • PkIELFIC-AFOS U411 K COfirlXHO WD-- I OR 2 _5...P-FEE5 wrmrps e vit mcrD ryT,.- w mam.*rr. m-trov I w-cr ay c' fis"I FRRONTS. t CW r '��LAM F, lft-1 t tor70"I'l.,LPAI`�14 M CNUY Af I n�v f n- 000 C -C Z Woo ----------- K 1<11170!, -COU 7`*� 2,5 0 crolInkii'T {;17F L '\-Sft N140 A C 3.0"Er lip DL Nif"1111 Dix A _50 11 FF, .72 a. a 7 0 .75 19 1.12 25 1.25 1-75 A'o 1.5c 3r 2XI) 51 0 F _j 2._ 3.C,71 76 1C 2 92 • a, Lu .)7 A a 3. 4.1,11 105 76 4- 1,to to as C, 21 to N of L _j3 CO _32 00 t;t so 00 5.to 50 41 SYNbd Co- Co."0 %'<K'1J4t 4?,43 1W 8-8*11 3.0 07.09.25 DESIGN MODIFICATIONS 2.0 05,14.25 COMPLETE DESIGN tott CE',AJL 50 s 00 SCALE 1,0'.0 1 .0 04.17.25 INITIAL DESIGN LAYOUT A, REV DATE DESCRIPTION 0 UTALOG F111iVITOL 114 F_NC`.CTVI E,6.12 1273 V,2A t�q2l In 9; 4 4.7P i Ncsf-v's 56.12 14;!, 3.3,24 E44 13 51 17f,1 51 NU,-V5 f-2.12 15-f1 24 erj 7 if;92 42 7 71-P 2 D_1 2 NC158VS 6a.12 1730 45.24 114? 119.�4 C 3 .152 NC 7,416 7412 1�11 ;1,24 1,,n 1 2 (146] �:51 v IN',,HES N1.11(W, 80.!2 703!) 1-7.24 1454 75.112' E16 kri - %�:rl 27,24 CW III 27,S 5?.52 1 461 !3.24 e44 MI 1 W.1 .!'q?4 q,� 16,M_2 411 3-/181 DFFP N(PIAV1 69.52 17(f, 45,24 114 10 rF.2 50 FEF F C E A RF-F NC7Av-' 7 1).t.,2 _!�1.74 M11- 22K PROJECT NAME fails__r, - WHOV' 01.52 ell 145* 7 fl.A 11 f`c- 4 !7.24 1 _14 214 5.J4 1(1;1.6 2P A2 732 kit 12 IC 2-5.0 0 'E;7o 2 t.0C 1 5 333 2 10C I E-535 NC44VS 44,12 1121 21.74 iq 7,H2 191) kil-1-12 NC4AiP 45,52 1131 23,24 5.11) 7.82 1 q'o Do E,r,r_,Ji,! 2_D 0 ;E 13 27.0r, (56 2 6.00', •E 6D•rrI NG,4 4-.11- 1.3 44.12 1121 21.74 t310 IU9 ELECTRIC VEHICLE Wl!= 3.9.0 1) 1 9"�I!, 33.0c. ?315, �!2.00' E.' 3 5fM2 1277 1 27.24 f.q�- 0 R2 5 2 CHARGING STATION VH4A 4-4 11 1 E 9 i�.()r I i� �i:t u,-,: f.,s j6.12 7421, 4 P4A 1.3 R? 3t I ir:3 62.i2 15-1 F. 24 4P7 427 F(' CC -1.0C -3 44.00 ' 176 P4 k,5 A�24 11 A�p INSTALLATION AT 11,11110 -1 12 7"D 4r Ile 2 173[1 50 [N-74V�,-171 74 12 IRR3 !',1 74 1,5r.I ki H.:,�- ;j.D,, 14 22, !,1.013 12 9'Li ';1-j.0C 2,`0 - 0.1�2 203t� 1454 Ft" ttb MATTITUCK, NY 11952 AKA L11-11F 2 62 07) 1'-',7 t-� !,7.1710 14-1 17'rno A22 Hc..!2 21 H11 C 3,24 1-Cl"f 2�1.LQ 732 -------------------------------------------------------------------------- -, . - _ I - -1:3 ji 1 2340 31,R2 t11115 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 21.52 0'01 0 20.12 NC'�W-, 53.12 t1,4Q 1 2-12 A 7M 313 3.40 1 [547' 121 32 4r FM51 -72.71 N �,j 24 70a l A' i L�n Fn,nn 1'1� #,p Ol '7?; Lii 12 93 _1 313 _3A - 1 _�42' '-- _­ - . I I f 32Fq NCC_�;�s 65.12 16?0_1 .24 10'3 to!2 4(5 52 2.21 07 405 lh�l,j A f----------- I0' C9.24 1750 1 31 92 8U8 ----- - cz NC92VS '42.12 1 H P SHEET TITLE u,)nr ------- 93.S2 2375 1 66.24 16112 1 92-tio 23,5--' 0J UI 221C A,-,-0 U •i 21U-1...... E-501 00 _40-- S I] - MH�l r EV PANEL DETAIL B PEc' SEAL PROJECT NO:LAUREL LINKS SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH CHECKED BY: rJa, Z, i 2 3 I CLIENT, PROPERTY OR OWNERS INFORMATION GALV.CAP(TYP.) 4715 GREAT PECONIC BAY BLVD 4811 LAUREL, NY 11948 TOP OF METER 1-v2"X1ar6" 6400 MAIN RD GALV.CHANNEL (TYP.) MATTITUCK, NY 11952 d NOTES 0 44" 1. CONTRACTOR TO SELECT APPROPRIATE SIGN PER PROPOSED SIGN LOCATION DESIGN CONSULTANT 2. BOTTOM OF LOWEST SIGN SHALL BE INSTALLED 66"ABOVE GRADE 3.BOTTOM OF LOWEST SIGN SHALL BE INSTALLED 80"ABOVE GRADE FOR ADA ROUTES TRANSFORMER 4"$CH.40 GALV.STEEL FILL PIPE WITH CLASS CONCRETE AND AND/OR PIPE(TYP.) PROVIDE WASH AT TOP OF PIPE CT CABINET low 6-0"MAX G1 17 4'-0"MIN' '1"0 GALV.U BOAT OR STRAP(TYP.) „ „ USE 4"GALVANIZED RIGID STEEL PIPE 1 1211 a„ ® (� _011 NOTE: FOR LOCKNUT SELF-CONTAINED (TYP.) --- V d METERS,MIN.HEIGHT 91 ��{ PROVIDE WASH FOR IN-LAWN INSTALLATIONS MAY BE T-0" 12"0 GONG.FILLED 12" 18" - - - - - - - - CHAMFER(TYP.) ® Arx SONOTUSE W1 =J1=J 1=1 i 1=1T I I I=1 11=1 11=1 11= J I I-III-III-III-I I-I i-I !-I I- 35" 14L AV 6"MIN. r (� W;� 1 �� CONDUIT 12" !e�/AV !Z !1� ` 3 -6 SUPPORT AS LLLPPP U"V LLLFFF111SSS U\1tt11 NEEDED CONTRACTOR or VENDOR W 4• ANCHOR (\rl POST IN NOTES: ®' DIG HOLE APPROX 16"0 FILL WITH CLASS ET 1. PRCNIDE4.5"SPACING S TWEEN(STENCILS CONCRETE WITHIN A FEW INCHES OF CONCRETE FINISHED GRADE 2. LOCATION:CENTER @ FOOT OF P/ARKING STALL SURFACE,FINISH USING APPROPRIATE WoodhoRow3. FONT:STANDARD GOTHIC MATERIAL 4. COLOR:WHITE ON EX.SURFACE(rNO FILL INSIDE STENCIL) r " ; EV PARKING SIGN DETAIL PROTECTIVE BOLLARD DETAIL 3'-6"MIN., STANDARD STALL MARKING DETAIL D_2 LOCKABLE CLIP BREAKERS D-3 D-a f' 103 School St, .t y.. Lindenhurst, NY 11757 UNDERGROUND SERVICE 6"MIN. ENTRANCE CONDUCTORS 60 PVC CR H-FRAME DETAIL OR RGS CONDUIT D'5 LEGAL NOTES: NOTES: 1. ASPHALT SHALL COMPLY WITH STANDARD DOT OR LOCAL JURISDICTION SPEC.FOR NOTES: "It is a violation of the state education law for any person, HMA SURFACE COURSE 1. ANY EXCAVATION LEFT OPEN NEEEDS TO BE FENCED,BARRICADED,OR TRENCH unless he or she is acting under the direction of a C0N CR TE 2. ANY EXCAVATION LEFT OPEN NEEDS TO BE FENCED,BARRICADED,OR TRENCH PLATED TO INSURE THE SAFETY I OF THE GENERAL PUBLIC licensed professional engineer to alter an item in anyway, PLATED TO INSURE THE SAFETY OF THE GENERAL PUBLIC 2. ANY PAVEMENT DAMAGE DURINCG CONSTRUCTION SHALL BE REPAIRED OR ASPHALT AREAS �► GRASS AREAS on this drawing and/or in this specification in anyway. If AREAS 2' 3. TRENCH DEPTHS ARE REQUIRED TO BE 2'-0"MIN.OR 6"BELOW FROST LINE PER REPLACED BY THE CONTRACTORR TO PRE CONSTRUCTION OR BETTER LOCAL JURISDICTION REQUIREMENTS 3. TRENCH DEPTHS ARE REQUIRED)TO BE -0"MIN OR 6"BELOW FROST LINE PER any such item is altered, the altering engineer shall affix to 6"CONCRETE 4. ANY PAVEMENT DAMAGE DURING CONSTRUCTION SHALL BE REPAIRED OR LOCAL JURISDICTION REQUIREMBENTS the item his or her seal and the notation "altered by" REPLACED BY THE CONTRACTOR TO PRE-CONSTRUCTION CONDITIONS OR BETTER 4. EXACT NUMBER OF CONDUITS SFHALL BE DETERMINED BY SHEET E-300.EXACT followed by his or her signature and the date of such 5. EXACT NUMBER OF CONDUITS SHALL BE DETERMINED BY SHEET E-300.EXACT CONDUIT PLACEMENT IN TRENCFH SHALL BE DETERMINED BY THE CONTRACTOR IN alteration, and a specific description of the alteration." 2^HOTMIxASPHALT-WEARING COURSE TACK COAT MIN 6'TOPSOIL SEED AND MULCH IN LAWN CONDUIT PLACEMENT IN TRENCH SHALL BE DETERMINED BY THE CONTRACTOR IN THE FIELD BASED ON PHYSICAL MMEASUREMENTS AND JURISDICTIONAL AREAS THE FIELD BASED ON PHYSICAL MEASUREMENTS AND JURISDICTIONAL REQUIREMENTS • Any errors and omissions in the drawing are to be ASPHALT JOINT SEALER- REQUIREMENTS checked by the general contractor and relayed to the GRADE NATIVE SOD architect FOR • Do not scale drawings • All work shall comply with the local building code(s) SAWCUT EXISTING PAVEMENT ASPHALT SURFACE EX.PAVEMENTF EX.PAVEMENT 1r 12, - - -_ -_ and with requirements of local AHJ SUB-BASE SUB-BASE - 111- =1I IH9 _r I . / AS _ I I EX.PAVEMENT BASE EX.PAVEMENT sAwcur IfT=TIT IIT- -II T 1=f11=111 um III 1 =11I =1TI=111=ITi=1il I - I, KEY PLAN 4'BITUMINOUS BINDER COURSEl- (I I 1 11 �7_� hT-(I-I I I _01 -0n UNDISTURBED SOIL -I j j�'PROVIDE TEMPORARY SHORN AS REQUIRED I--�_1 II-I (-I - I NATIVE SACKFILL UNDER OSHA REGULATIONS IIIT TRENCH UNDISTURBED SOIL CLEAN GRANULAR BACKFILL4"LIFT ON SITE BACKFILL ( MAXIMUM,PLANE TAMP O")SOIL -mI I III=IIIII -I F LOWABLE -�� I II I�I I COMPACTION MINIMUM OO I� -I III�L-1 T F,E N C H RESTORATION' DETAIL MIN.PLOWABLE FILL VERTICALLY AND (HAND TAMPED)"GRANULAR BACK BACKFILL VERTICALLY HORIZONTALLY BETWEEN CONDORS FILL i� 6 AND HORIZONTALLYG BETWEEN CONDUITS D-6 6" NON-UTILITY ASPHALT D_8 NON-UTILITY SOIL D-7 TRENCH DETAIL TRENCH DETAIL NOTES: 1 . TAP (4) M 12X 100 BOLTS INTO HOLES 2. DRILL MIN. 3" DEEP HOLES INTO CONCRETE FOLLOWING THE DRILLING TEMPLATE PROVIDED BY AUTEL 3. TIGHTEN MOUNTING BOLTS TO 442.3 IN*LBS 4. CONCRETE FOR MOUNTING MUST BE ABLE TO WITHSTAND COMPRESSIVE STRESSES LARGER THAN 2500 PSI 3.0 07.09.25 DESIGN MODIFICATIONS 5. PEDESTAL CAN BE MOUNTED DIRECTLY ONTO EXISTING 2.0 05.14.25 COMPLETE DESIGN EVCHARGERI CONCRETE SURFACES 1 .0 04.17.25 INITIAL DESIGN LAYOUT REV DATE DESCRIPTION NOTES: 1 . TAP (4) M12X100 BOLTS INTO HOLES 2. DRILL MIN. 3" DEEP HOLES INTO CONCRETE FOLLOWING BOLLARD(TYP.) 2.3793 THE DRILLING TEMPLATE PROVIDED BY AUTEL 1811 3. TIGHTEN MOUNTING BOLTS TO 442.3 IN*LBS 4. CONCRETE FOR MOUNTING MUST BE ABLE TO 811 WITHSTAND COMPRESSIVE STRESSES LARGER THAN 2500 6" MIN. o 0 5. PEDESTAL CAN BE MOUNTED DIRECTLY ONTO EXISTING 02 00.51 CONCRETE SURFACES CURB 6. FOOTING TO BE 4"-6" ABOVE GRADE FOR GRA',SS PROJECT NAME INSTALLATIONS d a 6" MIN. SINGLE BOLLARD PARKING LOT 7, FOOTING TO MATCH CURBLINE FOR ASPHALT d 41 I I ISEE INSTALLATIONS 8. SOME JURISDICTIONS REQUIRE FOOTING EXTEND DOWN 00.9517 d 4 d ° OT ELECTRIC VEHICLE TO FROST LINE (TYPICALLY 36" DEEP PER NOAA) ° EVICHARGER �11 </16 d d d I I M N 3" ° ## & 7 CHARGING STATION .3-4.9" EX. GRADE 4 < INSTALLATION AT I EX. GRADE 6400 MAIN RD 2.1890 d I 4 ° 4 MATTITUCK, NY 11952 BOLLARD(TYP.) d ° > 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 4 d I I 1 d d 4 d 4 . ° ,I 0 0 0 0 0.7 3.� ° 5 d d d I� ° SHEET TITLE 4 d I I ° a E-600 a CURB 0.2379 ° ' I I I ° 8" (SEE. 4 d PARKING LOT °61 MIN. 1 .8939 d DETAIL ° DUAL BOLLAD 1 .9463 ° NOTE d 4 ° #8) SEAL PROJECT NO:LAUREL LINKS 3.8069 d I I d SIGN AND SEAL SCALE:AS NOTED ° d DRAWN BY: NH a ° 1 PIEDESTAL SET BACK DETAIL d d a ° y � CHECKED BY: ° > ,� 18 18 ° 4 N u,I LEVEL 2 PEDESTAL NEW D-10 FOOTING DETAIL BY AUTEL PEDESTAL ELEVATION 07G. 02'HOLE TO MEET WITH CONDUIT FROM TRENCH NEW CONCRETE PAD "...� CLIENT, PROPERTY OR OWNERS INFORMATION 4715 GREAT PECONIC BAY BLVD LAUREL, NY 11948 6400 MAIN RD MATTITUCK, NY 11952 DESIGN CONSULTANT. 5,00 500 Soo & 350 Quadruplex U11R(D %Cab1e , _. u At, Specifications . ......... y � , r r e. .,;; Phase,I Size: 5 _1 y # r CDR t r Strand: CONTRACTOR or VENDOR; 0 CF � tWoodhollow Conductor Strand: . Insulaltion Thickness: 0.095 inches 103 School St, Lindenhurst, NY 11757 Outside Diameter: 2.348 inches Allowable Ar cs# -Drir # B rim: 4 7 Amps LEGAL NOTES, "It is a violation of the state education low for any person, unless he or she is acting under the direction of a Allowable Ampac'# -I Duch 4 1�y licensed professional engineer to alter an item in anyway, on this drawing and/or in this specification in anyway. If any such item is altered, the altering engineer shall affix to the item his or her seal and the notation "altered by" Weight. 2.174 g�lb q f IL followed by his or her signature and the date of such alteration, and a specific description of the alteration." • Any errors and omissions in the drawing are to be checked by the general contractor and relayed to the architect/EOR D:11 • Do not scale drawings • All work shall comply with the local building code(s) and with requirements of local` AHJ KEY PLAN 3.0 07.09.25 DESIGN MODIFICATIONS 2.0 05.14.25 COMPLETE DESIGN 1 .0 04,17.25 INITIAL DESIGN LAYOUT REV DATE DESCRIP71ON PROJECT NAME ELECTRIC VEHICLE CHARGING STATION INSTALLATION AT 6400 MAIN RD MATTITUCK, NY 11952 4715 GREAT PECONIC BAY BLVD, LAUREL, NY 11948 SHEET TITLE E-601 DETAIL SEAL PROJECT NO:LAUREL LINKS SIGN AND SEAL SCALE:AS NOTED DRAWN BY: NH rvNgrtoxN6'NoowULLpIMF8lGuetDN CHECKED BY: �0 +� ,r- 0 w 076 ,E Dr���