51377-Z
of sooryo!° Town of Southold * * P.O. Box 1179 �0 53095 Main Rd COUNT%�,�' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46622 Date: 10/24/2025 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 410 Sound Rd Greenport,NY 11944 Sec/Block/Lot: 3 5.4-16 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 04/18/2024 Pursuant to which Building Permit No. 51377 and dated: 11/14/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additions and alterations, including unfinished basement, screened porch, deck and roof patio, to existing single family dwelling as applied for. The certificate is issued to: Jay Hodges Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51377 10/07/2025 PLUMBERS CERTIFICATION: Carlo, . Tobar Catalan 09/12/2025 1 Autho ize S ature ho�aoF Sou ryolo TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51377 Date: 11/14/2024 Permission is hereby granted to: Jay N Hodges 3704 Bridle Path Austin,TX 78703 To: Construct additions and alterations to an existing single-family dwelling to include a rear screened porch and new rear deck as well as the demolition of existing rear entry porch with landing and existing rear deck as applied for. Premises Located at: 410 Sound Rd, Greenport, NY 11944 SCTM#35.-1-16 Pursuant to application dated 04/18/2024 and approved by the Building Inspector. To expire on 11/14/2026. Contractors: Required Inspections: Fees: DEMOLITION $70.00 Single Family Dwelling- Addition&Alteration $1,077.00 CO-RESIDENTIAL $100.00 Total $1,247.00 Building InspectorY� ho��pf SO(/r�Ql Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q Iy�OUNTY,Nc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jennifer Sinclair Address: 410 Sound Rd City: Greenport St: NY Zip: 11944 Building Permit#: 51377 section: 35 Block: 1 Lot: 16 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Got Power Inc. License No: 55837ME SITE DETAILS Office Use Only Indoor I✓ Basement FV Service W Solar (— Outdoor I✓ 1 st Floor Wo Pool F Spa r Renovation W 2nd Floor Hot Tub r Generator Survey Attic rl%o Garage Battery Storage (— INVENTORY Service 1 ph rV Heat Duplec Recpt 40 Ceiling Fixtures 9 Bath Exhaust Fan Service 3 ph r Hot Water 40A GFCI Recpt 18 Wall Fixtures 2 Smoke Detectors 4 Main Panel 200A A/C Condenser 2 Single Recpt Recessed Fixtures 10 CO Detectors Sub Panel A/C Blower 2 Range Recpt Elec. Ceiling Fan 4 Combo Smoke/CO 4 Transfer Switch UC Lights Dryer Recpt 30A Emergency Strobe Heat Detectors Disconnect Switches 39 4'LED Exit Fixtures Other Equipment: Fridge, Hood, Oven, Micro, DW, W/D, 200A Panel 40 Circuit/ 38 Used Notes: Two Story w/ Unfinished Basement Inspector Signature: X Date: October 7, 2025 Sean Devlin Electrical Inspector sean.devlina-town.southold.ny.us 410SoundRdHouse Ar Town Hall Annex �.Z► ye+� Telephone(631)765-1802 54375 Main Road .0 P. O. Box 1179 co Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: 7i Building Permit No. Owner: D (Please print) 1 ZPlumber: l D 6� Y � (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumbers Signature) Sworn to before me this /6-'5( day of 20 of Notary Public;: County MARY E:CPOGHAN NOTARY PUBLIC;STATE 0:NEW YOM A89'traticn No.01CFWS-.5486 Qualified in Suffo!!c county My COmmssiort Expires Jury 14,20 � of SOUIyo� # # TOWN .OF SOUTHOLD BUILDING DEPT. At "o ,� 631-765-1802 INSPECTION [ FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ . ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: (2,oL)V2 DATE /o?-/�- SL INSPECTOR /I') ho�aOF SOUIyo� # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 [N-SPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. VFOUNDATION 2NDA4-;-- [. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE.SAFETY INSPECTION [ .] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DU yotg&4A DATE INSPECTOR OF SOUlyolo # # TOWN OF SO.UTHOLD BUILDING DEPT. "co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ - ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ RAMING/STRAPPING [ ] FINAL [ ] -FIREPLACE & CHIMNEY [ .] FIRE SAFETY INSPECTION [ ] .FIRE RESISTANT CONSTRUCTION [ ] "FIRE RESISTANT PENETRATION . [ ] ELECTRICAL (ROUGH). [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: &KA l 1 vio( a, - viu5jr-u6g!!�jp -l-� cltl DATE ANSPECTOR UF SOUIyOIo �.l C - # OWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL - [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL- REMARKS: 17 DATE � INSPECTO 0f SOUlyolo '* * .TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECT ON [ ] FOUNDATION 1 ST/ REBAR [ OUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE &CHIMNEY [ .] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: b U (n12 I v 0 k,. DATE J�� -�S INSPECTOR oF soulyOl 51377 q[V 5o"d ` � o # # TOWN OF SOUTHOLD BUILDING DEPT. y� ,��� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL MARKS: od COOLi 6kfe+*&��A50- r LQ oudlQl 4 4 vie vt S` 6 e ko 4-as 6 4a , roll E 54t j- �dh 4e&) )WC kiAt UG p-mevi b ri tAi -:I'- DATE ��J INSPECTOR 11� •-__, �oy�00F 50UTyOlo TOWN OF SOUTHOLD BUILDING DEPT. coorm,N�` 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] RO H PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ .] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: a (oadok& At* it - - Cokvws �t GJZU"- C nn DATE. to �' INSPECTO _ ho�arsfso yob S-r 3 7 1-fr0 "4s-ou,,4 * # TOWN OF SOUTHOLD BUILDING DEPT. °you 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: q � A—L-- C—T-2 DATE INSPECTOR -� EF k 0 CT 2 2 2025 did ..►�" `ate"'. L 410 Sound Road Greenport, NY 11944 Q permit#51377 ��� • Z�� ' Jc—�s U handrail at front porch c r 410 Kl J w r r ��; Nor Y. ,y.y; .��� !w .t•'1^� -iw Sound R•.• Greenport, NY 11944 permit handrailporch t rTM ..fia . �i yid �S ) I 410 Sound Road Greenport, NY 11944 permit#51377 roof insulation at library addition 7.25" closed cell spray foam y w� r IM 410 Sound Road Greenport, NY 11944 permit#51377 roof insulation at kitchen addition 7.25" closed cell spray foam OCT 2 2 2025 F?terEtrf!n Department SjoioId _ F f l t � yy 410 Sound Road Greenport, NY 11944 permit#51377 roof insulation at exposed 2nd floor ceiling R15 fiberglass FIELD INSPECTION REPORT DATE COMMENTS (( nn v 1 ►o a. .aKe hcre V Ac, s RsFIAII . FOUNDATION'(1ST) ------------------------------------ -a a o &L e)l,. vkn�: con FOUNDATION (2ND) z 3•a`7•z Fr'z�.r v. S�i�.�opr 0�. w � i de - vi jAA4, � 0(� L o y ROUGH PLUMBING & Pou 1V l��5 OIL r INSULATION PER N.Y. STATE ENERGY CODE C FINAL 7? -� o ti ov4 ADDITIONAL COMMENTS Q 4- coec 3— B 2 S o� 3bD l� rR c, !0 9U 8 o - )tar, Ea _ Z - � x b N � — x r� d r -a f i plibkRTY INrORMATION Existing use of property:single-family res. Intended use of property:single-family res. Lone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? Dyes®No IF YES,PROVIDE A COPY. I9 Check Fox After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 296 of the Town code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant ogees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In buildings)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section Z10.45 of the New York State penal low. I 41roSADHI a elle Application Submitted By(p ' e): ,� h BAuthorized gent �o,�iner i D.BUNCH Signature of Applicant: State of New York Date:U6185050 STATE OF NEW YORK) Suffolk CountyCommission xp 14,2�k SS: COUNTY OF Suffolk Jake LaChapel le being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the Work will be performed in the manner set forth in the application file therewith. Sworn before me this �Jday of r/ .20�! Notary Public PROPERTY OWNER AUTHORiZATION (Where the applicant is not the owner) 11 Jay Hodges residing at 410 Sound Road, Greenport, NY 11944 do hereby authorize Jake LaChapelle to apply I on my ehalf to the T wn of outhold Building Department for approval as described herein. � 1 (�, Zy Owner's 'gnature Date Jay Hodges Print Owner's Name BUILDING DEPARTMENT- Electrical Inspector 441-� �Gy TOWN OF SOUTHOLD t cm Town Hall Annex - 54375 Main Road - PO Box 1179 `n Southold, New York 11971-0959 O4� �p�v4� Telephone (631) 765-1802 - FAX (631) 765-9502 9 iamesh D-southoldtownny.gov -- seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: p3 0-� 20 Z 5 Company Name: o w ZY / A/C Electrician's Name: License No.: — 5 g3 Elec. email: Elec. Phone No: 63 :Ri` 101 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: U n 1P [ Phone No.: a 5 — 16 Bldg.Permit#: ',. 3V:4' email: ��►U�V" D n m? iia Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: c4t- I g Is job ready for inspection?: YES �NO [:]Rough In ❑ Final Do you need a Temp Certificate?: YES ❑ NO , Issued On eFwt;A. .LcC a Temp Information: (All information required) Service Size©1 Ph❑3 Ph Size: 2 L)_A # Meters I Old Meter# 9&17,145 [ONew Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground QOverhead # Underground Laterals 1 2 H Frame Pole Work done on Service? DY N Additional Information: PAYMENT DUE WITH APPLICATION 32-g oL- ^ faoO. &*VIC-C / 00 rec-r IOG�aS '�30- �P� 513-71 o�s�Ffrot,��oa yJ► BUILDING DEPARTMENT-Electrical Inspector N = TOWN OF SOUTHOLD o 1W Town Hall Annex-54375 Main Road-PO Box 1179-Southol;d, NY 11971-0959 y�lpl dap! Telephone(631)765-1802 Temporary Certificate # 190 Date W10.�� oZ 8 2025 Customer Name 1--, /& Electrician-Name p C -z a r' Addressa 10 % 6 ►^tsti Phone 4e5l .-7 67 3 e-mail e-mail .160" Phone License# M 9� -55 83? Size o2 O0 A Phase Overhead Underground #of Meters / Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y N a Flood Reconnect Old Meter# Service Reconnected Application for electrical service equipment is on file with the town of Southold.on the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 days from the date above. Authorized by :5 13?? q10 S©Jnd a 6reenNoAj V Y GARAGE • Sub Panel: 100AOs • Sauna Heater: 30AMPS 1 • GFC$ Receptacle: 20AMPS (x7) • Recessed Fixtures (x60) • Wall Fixtures (x2) a • Exterior Lights (x3) • Lights Switches (x5) 2 Story house and unfinished basement • Main Panel 200AMPS 1 Phase • Water Heater receptacle-40AMPS • Dryer Receptacle- 30AMPS • A/C Condenser-30AMPS • A/C Condenser-40AMPS • A/C Blower-40AM PS • A/C Blower-60AM PS • GFCt,Receptacle-20AMPS (X18) • Duplex Receptacle-15AMPS (X40) e • Recessed Fixtures (x45) • Ceiling Fixtures (x9) • Wall Fixtures (x2) • Exterior Lights (x10) • Lights Switches (x39) • Bath Exhaust fan (x2) • Ceiling Fan (x4) • Combo Smoke/co dector • Smoke Detector(x4) • Fridge • Hood • Microwave • Dishwasher • Washer e CERTIFICATIONS HEREON SIGNIFY THAT THIS PUT OF PROPERLY IS A TRUE AND CORRECT REPRESENTATION OF A RECENT SURVEY MADE UNDER MY DIRECTION IN ACCORDANCE WITH THE EIOSTING CODE OF PRACTICE FOR LAND SURVEYORS BY THE NEW YORK SPATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. SAID CERTIFICATIONS SHALL RUN ONLY TO THE PERSON WHOM THE SURVEY WAS PREPARED AND ON THEIR BdULLF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON.THIS COUMCA17ON IS ONLY FOR THE LANDS DESCRIBED HEREON, ITS NOT A CERTIFICATION OF TITLE, ZONING, OR FREEDOM FROM ENCUMBRANCES. CERTIFICATIONS ARE NOT NOT TRANSFERABLE TO ADDITIONAL OR SUBSEQUENT OWNERS. TAX LOT 24 S 27047'30" E 75.00' REBAR PIPE FOUND FND. FE FE O.I N L I'S X W U z m w� � o d: I co X xl 1 r FE 2.7'S `l FE ' 3.1'S 3 } ; l FE BLDG. 1.6W 1.6'S TAX W TAX LOT o LOT 15 Q N = ix 17 14.1' R/G FE I WOOD L3'N PORCH FF8.3' Ll o1 F � i 13.8' DECK 1 5.0' a y, L W >1� � 1 1/2 STORY �O FRAME a d w> a DWELLING 00 00 x> 8 N N 3( J 0 0 4 Iz.r 12.1'. ' N N FE > 1 Call I.iN sl o w 8.9' WOOD x PORCH )) t; 3 83.21' PIPE j PIPE END.i END. -� WOOD l ^�L. .�. .. :.v FENCE ROW ^OF SHRUBS N 27031'20" W 75.00' S(::)TJISTJD ROAD THE OFFSETS OR DIMENSIONS SHOWN FROM THE IMPROYEM9M TO THE PROPERLY LINES ARE FOR A SPECIFIC PURPOSE AND USE,AND THEREFORE ARE NOT INTENDED TO BE USED AS A GUIDE IN THE ERECNDN OF FENCES,WALLS,POOLS, PATIOS, BUILDINGS,ADDTIONS TO BUILDINGS OR ANY OTHER IMPROVEMENTS SUBSURFACE AND ENVIORNMENTAL CONDITIONS NOT SHOWN. PROPERTY CORNER MARKERS WERE NOT SET AS A PART OF THIS SURVEY. EASEMENTS AND OR RIGHTS—OF—WAY OF RECORD, IF ANY, NOT SHOWN. PJM LAND SURVEYING, PLLC UNAUTHORIZED ALTERATION OR 132 CLYDE STREET/SUITE 16 ADDMON TO THIS SURVEY IS A 7209 OF WEST SAYVILLE,NY 11796 VIOLATION NEW SECTION TATE EDUCATION LAW. L PHONE 631-563-0400 NEW YORK SIOA FAX 631-563-5808 PJMSURVEYING AOL.COM LOT:--- REVISIONS J/ . MAP OF:DESCRIBED PROPERTY FILED:---- NO:---- COUNTY: SUFFOLK SITUATE:GREENPORT TOWN OF SOUTHOLD COPIES OF THIS SURVEY MAP NOT CERTIFIED TO: TITLE NO.:7404-017069 EMBOSSED SEAL�AND SIGNATURE SHALL NOT BE CONSIDERED A TRUE JAY H.HODGES AND VALID COPY FIDELITY NATIONAL TITLE INSURANCE COMPANY PROJECT NO.:2023-292 IDATE: 10/1.8/2023 DRAWN: CM CHECKED BY:PM SCALE: 1"=20' DISTRICT: 1000 SECTION:35 BLOCK: 01 LOT(S): 16 Generated by REScheck-Web Software Compliance Certificate Project 410 Sound Road - ALTERATION Energy Code: 2018 IECC ✓ Location: Greenport, New York Construction Type: Single-family ' Project Type: Alteration Project SubType: None Climate Zone: 4 (5572 HDD) Permit Date: NOV 15 2024 Permit Number: All Electric false Is Renewable false Has Charger false �r a Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 410 Sound Road Jay Hodges Jake LaChapelle Greenport, NY 11944 LaChapelle Architeture PLLC P.O. Box 1251 Mattituck, NY 11952 Compliance:I. . prescriptive - . Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Roof: Flat Ceiling or Scissor Truss --- --- --- --- --- --- --- Exemption: Framing cavity filled with insulation Wall 1:Wood Frame, 16"o.c. --- --- --- --- --- --- --- Exemption: Framing cavity filled with insulation Entry door(1): Solid 19 0.320 0.320 6 6 Bedroom 3 door(20): Glass 41 0.300 0.320 12 13 SHGC:0.28 Window replacement:Vinyl/Fiberglass Frame:Double Pane with Low-E 214 0.300 0.320 64 68 SHGC:0.28 Basement Wall 1: Masonry Block with Empty Cells Wall height: 0.0' Depth below grade: 0.0' --- --- --- --- --- --- --- Insulation depth: 0.0' Exemption: Framing cavity not exposed. Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has en designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the man ry re uire nt listed in the REScheck Inspection Checklist. Name-Title S' atur V Dat ED AR C9 ti LAch/gA C'SV 9 033930 Q� O ccOF NE`N� Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 2 of10 CREScheck Software Version : REScheck-Web �J( Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Complies? Comments/Assumptions & Req:ID Value Value 103.1, ;Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PRl]1 ;energy code compliance for the ;building envelope.Thermal ❑Not Observable envelope represented on J❑Not Applicable ,construction documents. 103.1, ;Construction drawings and ❑Complies 103.2, :documentation demonstrate ❑Does Not 403.7 ;energy code compliance for [PR3]1 ;lighting and mechanical systems ❑Not Observable 4, :Systems serving multiple ❑Not Applicable ; ;dwelling units must demonstrate ;compliance with the IECC a ' :Commercial Provisions. I 302.1, Heating and cooling equipment is; Heating: Heating: ;❑Complies 403.7 sized per ACCA Manual S based ; Btu/hr Btu/hr T Does Not [PR2]2. ;on loads calculated per ACCA ; Cooling Cooling ❑Not Observable Manual J or other methods Btu/hr ; Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 3 of10 Section Plans Verified Field°Verified, # Foundation Inspection .. Complies? Comments/Assumptions & Re .ID Value'.. Value 402.1.1 ;Conditioned basement wall R- ; R- ;❑Complies ;See the Envelope Assemblies [F04]3- insulation R-value.Where interior: R_ R_ ;❑Does Not ;table for values. V ,insulation is used,verification may need to occur during ; :❑Not Observable Insulation Inspection.Not 1❑Not Applicable ;required in warm-humid locations; .in Climate Zone 3. 1 303.2 {Conditioned basement wall ❑Complies [F05]1 :insulation installed per ❑Does Not v :manufacturer's instructions. ❑Not Observable ❑Not Applicable ; 402.2.9 Conditioned basement wall ft ft ;❑Complies ;See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not ;table for values. J ;distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 'A protective covering is installed ❑Complies [FO11]z !to protect exposed exterior []Does Not ;insulation and extends a ; minimum of 6 in. below grade. ❑Not Observable []Not Applicable ; 403.9 ;Snow-and ice-melting system ❑Complies ; [FO12]2 :controls installed. ❑Does Not ❑Not Observable []Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 4 of10 Section plans Verified Field;Verified #" Framing/Rough InAnspection ..Complies?:. Comments/Assumptions & Req:ID Value ;'Value 402.1.1, ;Door U-factor. U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.4 ❑Does Not :table for values. [FR1]1 U i : :❑Not Observable ; ;❑Not Applicable ; 402.1.1, ;Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, :average). ❑Does Not :table for values. 402.3.3, 402.5 :❑Not Observable : [FR2]1 I ;❑Not Applicable 303.1.3 ;U-factors of fenestration products ❑Complies [FR4]1 :are determined in accordance ❑Does Not ;with the NFRC test procedure or ;taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not v j instructions. ❑Not Observable : IE]Not Applicable 402.4.3 ;Fenestration that is not site built f❑Complies [FR20]1 is listed and labeled as meeting i❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable : 1400 that do not exceed code ❑Not Applicable limits. 402.4.5 :IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not ),and labeled to indicate s2.0 cfm leakage at 75 Pa. ❑Not Observable : ❑Not Applicable ; 403.3.1 ;Supply and return ducts in attics i:, ❑Complies ; [FR12]1 :insulated >= R-8 where duct is El Does Not v ;>= 3 inches in diameter and >_ R-6 where < 3 inches.Supply and ❑Not Observable : return ducts in other portions of ❑Not Applicable ;the building insulated >= R-6 for ,diameter>= 3 inches and R-4.2 : :for< 3 inches in diameter. 403.3.2 ;Ducts, air handlers and filter ❑Complies [FR13]1 :boxes are sealed with ❑Does Not V ;joints/seams compliant with ❑Not Observable :International Mechanical Code or :International Residential Code,as ❑Not Applicable applicable. ; 403.3.5 Building cavities are not used as 6❑Complies [FR15]3 ducts or plenums. El Does Not 'J : []Not Observable ' IE]Not Applicable 403.4 ;HVAC piping conveying fluids R- R- ;❑Complies : [FR17]2 ;above 105°F or chilled fluids ;❑Does Not below 55°F are insulated to?R- ; J 3 : ;❑Not Observable ' ;❑Not Applicable 403.4.1 ;.Protection of insulation on HVAC JOComplies [FR24.]1 piping. ❑Does Not l®J ❑Not Observable I❑Not Applicable 403.5.3 ;Hot water pipes are insulated to R- R- ;❑Complies [FR18]2 i>_R-3. : :❑Does Not :❑Not Observable ; ,❑Not Applicable ; 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 5 of10 Section Plans Verified Field Verified # Framing/Rough-In_Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.6 ,Automatic or gravity dampers area ❑Complies (FR19)2 installed on all outdoor air ❑Does Not ;intakes and exhausts. ❑Not Observable IE]Not Applicable ; Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 6 of10 Section Plans Verified Field Verified. # Insulation'lnspection Complies? . Comments/Assumptions & Req.ID- Valuery Value , 303.1 ;All installed insulation is labeled ❑Complies [IN13]z or the installed R-values ❑Does Not ;provided. ❑Not Observable i I❑Not Applicable 402.1.11 ;Wall insulation R-value. If this is a: R- R- :❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ; Wood ;❑ Wood ;❑Does Not ;table for values. 402.2.E ;wall insulation on the wall ;❑ Mass ❑ Mass ;❑Not Observable ' [IN3]1 ;exterior,the exterior insulation ; CO) :requirement applies(FR10). ;❑ Steel ❑ Steel ;❑Not Applicable ; I I ; 303.2 ;Wall insulation is installed per ❑Complies [IN4]1 :manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 7 of10 Section Plans Verified Field.Verified. # Final Inspection Provisions Complies? Comments/Assumptions &Re .ID Value . Value 402.1.1, ;Ceiling insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, ;❑ Wood ;❑ Wood ',❑Does Not table for values. 402.2.2, ;❑ Steel ;❑ Steel ;❑Not Observable 402.2.E[Fill' ;❑Not Applicable � j 303.1.1.1, ;Ceiling insulation installed per ❑Complies 303.2 ;manufacturer's instructions. ❑Does Not [FI2]1 ;Blown insulation marked every ,300 ft2. IE]Not ❑Not Observable Applicable 402.2.3 ;Vented attics with air permeable ❑Complies ; [F122]2 ;insulation include baffle adjacent ❑Does Not ;to soffit and eave vents that SS ; ;extends over insulation. - ;❑Not Observable , 33❑Not Applicable ; 402.2.4 ;Attic access hatch and door R- R- ;❑Complies [FI3]1 insulation ?R-value of the :❑Does Not ;adjacent assembly. ; ;❑Not Observable :,[]Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ; ACH 50= ;❑Complies [FI17]1 each in Climate Zones 1-2,and T❑Does Not <=3 ach in Climate Zones 3-8. ; I ;❑Not Observable ; ❑Not Applicable 402.4.2 Woad-burning fireplaces have i ❑Complies (FI8]z ,tight fitting flue dampers and ❑Does Not outdoor air for combustion. ,❑Not Observable y ❑Not Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [FI27]1 :determine air leakage with ft2 ftz ;❑Does Not ;either: Rough-in test:Total ; leakage measured with a ,❑Not Observable :pressure differential of 0.1 inch :❑Not Applicable w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total ; leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air I handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 ; cfm/100 ;❑Complies [FI4]1 ;cfm/100 ft2 across the system or ft2 ftz ;❑Does Not <=3 cfm/100 ft2 without air ; handler @ 25 Pa. For rough-in ; ;❑Not Observable :tests,verification may need to ; ;❑Not Applicable ;occur during Framing Inspection. ; 403.3.2.1 ;Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of }❑Does Not ;design airflow. ❑Not Observable ; ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Flg]z installed for control of primary ❑Does Not ;heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 ion heat pumps. []Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 8 of10 Section - Plans Verified '.Held,Verified # Final Inspection Provisions Complies?. Comments/Assumptions & Req.ID Value; Value 403.5.1 4 Circulating service hot water ` ❑Com lies [FI11]2 ~systems have automatic or .`❑Does Not ,accessible manual controls. ;❑Not Observable �❑Not Applicable 403.6.1 ;All mechanical ventilation system ❑Complies ; [F125]2 Mans not part of tested and listed - ❑Does Not j HVAC equipment meet efficacy i and air flow limits per Table []Not Observable R403.6.1_ S ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ?control to lower boiler water ❑Not Observable ; 'temperature based on outdoor ❑Not Applicable ;temperature. , 403.5.1.1 ;Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not ;system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply ;pipe. Gravity and thermos- ❑Not Applicable ; ;syphon circulation systems are not present.Controls for ; circulating hot water system pumps start the pump with signal ;for hot water demand within the occupancy.Controls ;automatically turn off the pump ; when water is in circulation loop ; is at set-point temperature and - no demand for hot water exists. y 403.5.1.2 ;Electric heat trace systems JElComplies ; (FI29]z (comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the []Not Observable heat tracing to maintain the ❑Not Applicable ; desired water temperature in the piping. 403.5.2 ;Demand recirculation water ❑Complies (F130]2 (systems have controls that ❑Does Not manage operation of the pump b ;and limit the temperature of the []Not Observable water entering the cold water ❑Not Applicable piping to<= 104°F. ; 403.5.4 Drain water heat recovery units ❑Complies ; [F131]2 'tested in accordance with CSA ❑Does Not B55.1. Potable water-side ❑Not Observable I pressure loss of drain water heat 'recovery units < 3 psi for I j❑Not Applicable individual units connected to one or two showers. Potable water- s 'side pressure loss of drain water ;heat recovery units<2 psi for individual units connected to ' ;three or more showers. 404.1 ;90%or more of permanent JE]Complies ; [F16]1 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 ;Fuel gas lighting systems have ❑Complies ; [FI23]3 no continuous pilot light. PDoes Not 1[]Not Observable ; 5E]Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 9 of10 Section Plans Verified Field Uer�fied # Final Inspection`Provisions Complies? 'Comments/Assumptions, & Re :ID V alue� value t, 401.3 Compliance certificate posted. ❑Complies [F17]2 z ❑Does Not j ❑Not Not .r_.❑Not Applicable 303.3 ;Manufacturer manuals for ri i❑Complies ; [FI18]3 ;mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ; i i❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 410 Sound Road -ALTERATION Report date: 11/15/24 Data filename: Page 10 of10 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 0.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling/ Roof 0.00 Ductwork (unconditioned spaces): Glass & Door Rating. LI-Factor SHGC Window 0.30 0.28 Door 0.30 0.28 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Date: Comments APPROVED AS NOTED COMPLY WITH ALL CODES OF DATE: " 2� B.R# 13� � NEW YORK STATE&TOWN CODES 12y bo S REQUIRED AND CONDITIONS OF FEE BY ��� UMLD TOWN M NOTIFY BUILDING DEPARTMENT AT SUMTOWN RAI M IDW 631-765-1802 8AM TO 4PM FOR THE mmm FOLLOWING INSPECTIONS: ItY.&DW FOUNDATION-TWO REQUIRED FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. TRUSS pLACARDIRIG REQUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS Mechanical Ventilation system shall be required e per NYS Energy ELECTRICAL INSPECTION REQUIRED Blower door and ductwork PLUMBER CERTIFICATION testing required' ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY SOLDER USED IN WATER Must provide Manuals SUPPLY SYSTEM CANNOT D,J and S as per EXCEED 2110 OF 1% LEAD. NyS Energy Code PLUMBING RETAIN STORM WATER RUNOFF ALL.PLUMBING•WASTE &yVI 'TER LINES NEED PURSUANT TO CHAPTER 236 TESTING BEFORE COVERING OF THE TOWN CODE -)k Provide. Loirdborrw ��6y-is P-4cc,+jon as Vic ui(yd pa, tow Rebiden+jm Coo e O-P r j 1 HODCES RESIDENCE 410 SOUND ROAD 10 GREENPORT,NY 11944 SO' UND ROAD ADDITION GREENPORT, NY AKA '20 SOUND ROAD' DRAWING LIST TRUE O ADDITION TO PRIMARY STRUCTURE A1.00 TITLE SHEET NORTH A2.00 NOTESgo A3.00 SCHEDULES SCTM#-1000-35.-1-16 DO NOT SCALE FROM DRAWINGS A4.00 NAILING&STRAPPING PROJECT 13 A5.00 SITE PLAN (27.52°> A6.00 EXISTING BASEMENT PLAN A7.00 EXISTING FIRST FLOOR PLAN TAX MAP NO.100035.1-16 SYMBOLS SCOPE OF WORK A8.00 EXISTING SECOND FLOOR PLAN # ISSUE/REVISION DATE A9.00 NEW BASEMENT PLAN A10.00 NEW FIRST FLOOR PLAN .00 REVISED FILING SET-ADDITION 10.28.2024 THE GENERAL INTENT OF THE WORK IS TO BUILD AN ADDITION AND A11.00 NEW SECOND FLOOR PLAN LEVEL DECK AT THE REAR OF THE EXISTING HOUSE AND PERFORM LIMITED Al2.00 NEW ROOF FRAMING PLAN OTHIRD FLOOR ALTERATIONS WITHIN THE HOUSE. NO CHANGE OF USE OR A15.00 WEST&SOUTH ELEVATIONS A WINDOW EL. +31'-3" OCCUPANCY IS PROPOSED. A16.00 EAST&NORTH ELEVATION ELEVATION ABOVE 0'-0" A17.00 SECTION DRAWN BY:J.LACHAPELLE 2O DOOR REGULATORY NOTES A16.00 PART PLANS A19.00 INTERIOR ELEVATIONS- LIBRARY CHECKED BY:I.LACHAPELLE ELEVATION NUMBER A20.00 INTERIOR ELEVATIONS- PORCH NOTE;THIS IS ANIi°x17"SHEET 1O PARTITION TYPE. A6 SHEET NUMBER 1. THIS APPLICATION FOR PERMIT IS FILED WITH THE TOWN OF A21.00 INTERIOR ELEVATIONS- KITCHEN DRAWINGS MAY BE PRINTED NOT TO SCALE SOUTHOLD BUILDING DEPARTMENT, IN CONFORMANCE WITH A23.00 DETAILS THE TOWN CODE CHAPTER 144. A24.00 DETAILS LaChapelle Architecture PLLC 1 2. THE CONTROLLING CODE IS THE 2020 BUILDING CODE OF NEW A25.00 DETAILS P.O.Box 1251 A3 DETAIL NUMBER YORK STATE AND THE 2020 ENERGY CONSERVATION CODE OF Mattituck,NY 11952 A4 SHEET NUMBER NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. (646)251-5058 jake@lachapellearchitecture.com 3. REFERENCE HEREIN TO'BC' SHOULD BE CONSTRUED TO MEAN THE APPLICABLE BUILDING CODES OF NEW YORK STATE. ABBREVIATIONS 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS - RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) A.F.F. ABOVE FINISH FLOOR HM HOLLOW METAL \��ERED q,4c (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. ALT ALTERNATE HT HEIGHT �� �ELAOKgo� STAIR DIRECTION LABELS 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED APP. APPLIANCE(S) HW HOT WATER 00 HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES, -' UP DN AND REGULATIONS. CLG CEILING PTD PAINTED CONIC CONCRETE N ��� $C SMOKE+CARBON MONOXIDE DETECTOR INSPECTIONS CONT. CONTINUOUS RCP REFLECTED CEILING PLAN 3� °�0 CONT'D CONTINUED SMOKE AND CO DETECTORS SHALL COMPLY O.C. ON CENTER OF NEW WITH UL 268,7th ADDITION SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE D.O. DOUBLE HUNG REQUIREMENTS OF BCNYS 1704&1705. DIM. DIMENSION P.T. PRESSURE TREATED MATCH LINE DIA. DIAMETER DISC. DISCONTINUOUS SIM. SIMILAR ""` ""�°"`°" FOOTING °�"°� - N,.wm,�m. °RAVE ,RFSP-E.,,°r.�- ENTER LINE DWG DRAWING S.S. STAINLESS STEEL Coro ;;„ FOUNDATION FRAMING,TIE-DOWN/STRAPPING AND PLUMBING STL. STEEL �-- BREAK LINE PERIMETER INSULATION ELEC. ELECTRIC ROUGH ELECTRIC ENG. ENGINEER TYP. TYPICAL TITLE SHEET INSULATION AND CAULKING EQ. EQUAL ENERGY CODE COMPLIANCE EXIST. EXISTING V.I.F. VERIFY IN FIELD FINAL FL FLOOR W/ WITH SHEET NO: WRB WEATHER RESISTIVE Al GWB GYPSUM WALL BOARD BARRIER SHEET 1 OF 22 GENERAL NOTES GENERAL NOTES FIXTURE & FINISH NOTES HODGES 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 11. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED 1. THE OWNER WILL PROVIDE THE CONTRACTOR AN 'OWNER'S RESIDENCE ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND LIST OF FIXTURES AND FINISHES',WHICH IS SUBJECT TO 410SOUND ROAD DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE CHANGE.THE CONTRACTOR 15 RESPONSIBLE FOR PURCHASING GREENPORT,NY 11944 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY INSPECTOR. THESE FIXTURES AND FINISHES AND FOR COORDINATION AND PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE PURCHASE OF ALL ACCESSORIES,ALL RELATED WORK, DELIVERY FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL 12. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT AND INSTALL. WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND 2. IN CASES WHERE THE OWNER CHOOSES TO PURCHASE ANY ® O SYSTEMATIC MANNER. INSURANCE REQUIREMENTS. GOODS THE CONTRACTOR SHALL NOTE THAT THE OWNER TRUE WILL NOT BE ON SITE TO TAKE DELIVERY OF OWNER-ORDERED NORTH 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE 13. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE GOODS. IN ALL CASES CONTRACTOR IS RESPONSIBLE FOR BUILDING CODES,ALL WORK MUST CONFORM TO FIRE BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER CHECKING DELIVERIES, FOR REJECTING ANY DAMAGED DEPARTMENT REGULATIONS, UTILITY COMPANY AND RECEIPT OF WRITTEN CONSENT. DELIVERIES OR DELIVERIES NOT MATCHING BILL OF LADING, PROJECT O REQUIREMENTS,AND BEST TRADE PRACTICES. AND FOR NOTIFYING OWNER OF FLAWED DELIVERIES FOR NORTH7.52R) 1'4. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE RE-ORDER BY OWNER. RETURNS OF OWNER-PURCHASED 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS GOODS WILL BE MADE BY OWNER. IN ALL CASES CONTRACTOR TAX MAP NO.1000-35:1-16 FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY SHALL BE RESPONSIBLE FOR PREPARATION OF SURROUNDING # ISSUE/REVISION DATE DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. WORK FOR INSTALLATION, COORDINATION OF ALL PLUMBING, TO THE ARCHITECT. ELECTRICAL,AND ANY OTHER RELATED WORK, PROVISION OF .00 REVISED FILING SET-ADDITION 10.28.2024 15. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN ALL NECESSARY ACCESSORY MATERIALS,AND ACCEPTABLE 4. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS INSTALLED PRODUCT. VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA CONCRETE IS PLACED,AND SUBMIT TO SOUTHOLD BUILDING 3. KITCHEN CABINETRY WILL BE PURCHASED BY OWNER FROM CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION DEPARTMENT. RIVERHEAD BUILDING SUPPLY OR SIMILAR SUPPLIER. ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION CONTRACTOR IS RESPONSIBLE FOR PREPARATION OF A EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A 16. PRIOR TO COMMENCING OPERATIONS ON SITE THE SUITABLY CONTINUOUS, LEVEL,AND PLUMB SUBSTRATE, DRAWN BY.J.LACHAPELLE RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT COORDINATION OF ALL PLUMBING, ELECTRICAL,AND HVAC CHECKED BY.J.LACHAPELLE THOSE SHOWN.CONTRACTOR SHALL NOTIFY ARCHITECT OF 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS WORK, INSTALLATION OF CABINETS AND COUNTERS,AND NOTE:THIS IS AN II°x17"SHEET DISCREPANCIES AS THEY ARISE. ADDITIONALLY INSURED: PROVISION OF ALL NECESSARY ACCESSORY MATERIALS TO DRAWINGS MAY BE PRINTED NOT TO SCALE JAY HODGES ACHIEVE ACCEPTABLE INSTALLED PRODUCT. CONTRACTOR TO 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY LACHAPELLE ARCHITECTURE PLLC OBTAIN CABINET SHOP DRAWINGS FROM OWNER IN ORDER TO LaChapelle Architecture PLLC FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY COORDINATE THE WORK. P.O.Box 1251 SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE KIND UNTIL THE ABOVE IS PROVIDED. 4. PLUMBING FIXTURES WILL BE PURCHASED BY CONTRACTOR Mattituck,NY 11952 DRAWINGS. PURSUANT TO OWNER'S LIST. 17. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY OF 4.1. TOILETS ARE LIKELY TO BE FLOOR-MOUNTED MODELS (646)251-5058 jake@lachapellearchitecture.com 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES ALL AREAS OF THE WORK THROUGHOUT OPERATIONS.THE THROUGHOUT. WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS 4.2. SHOWER BASES WILL BE PORCELAIN TILE. ARE NECESSARY, INCLUDING BUT NOT LIMITED TO RETAINING A 5. LIGHT FIXTURES WILL BE PURCHASED BY CONTRACTOR FtI-D ARC 7. THE STRUCTURAL MODIFICATIONS TO THE HOUSE INCLUDED LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO PURSUANT TO OWNER'S LIST. EACH HEREIN MAKE THIS A LEVEL 2 ALTERATION UNDER EXISTING OVERSEE AND ADVISE ON THE WORK. 6. . VENTILATION FANS FOR BATHROOMS WILL BE PURCHASED BY �� ��`�_A BUILDING CODE (EBC) CHAPTER 6. REQUIREMENTS OF BC CONTRACTOR PURSUANT TO OWNER'S LIST. CHAPTER 7 AND 8 APPLY AS A RESULT.CONTRACTOR SHALL 7. CEILING FANS WILL BE PURCHASED BY CONTRACTOR PURSUANT ' CAREFULLY OBSERVE THE REQUIREMENTS OF SECTION 806. ENERGY NOTES TO OWNER'S LIST. it 8. VENTILATION HOOD FOR KITCHEN RANGE WILL BE PURCHASED 8. STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.E BY CONTRACTOR PURSUANT TO OWNER'S LIST. '� BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK 1'. THE WORK PROPOSED HERE MUST CONFORM TO ECCNYS R502 '9j. 0 FOR ADDITIONS WHERE APPLICABLE,AND TO ECCNYS R503 9• FLOOR AND WALL TILE WILL BE PURCHASED BY CONTRACTOR F CATEGORIES AND NOT A HIGH-RISE BUILDING. W REQUIREMENTS FOR ALTERATIONS WHERE APPLICABLE. PURSUANT TO OWNER'S LIST. CONTRACTOR TO COORDINATE OF NE QUANTITIES. 9. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. 2 AS REQUIRED BY ECCNYS TABLE R402.1.2 THE NEW PERIMETER 10. REFRIGERATOR(S)AND MICROWAVE WILL BE PROVIDED BY TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 WALL ASSEMBLY MUST ACHIEVE R-20.THE NEW ROOF ASSEMBLY OWNER FOR INSTALLATION BY CONTRACTOR,AND ARE AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD BUILT-IN UNITS. RANGE WILL BE PROVIDED BY OWNER FOR ^�°PR q1 °a°^a^ �_�..."°°"°"'T"` MUST ACHIEVE R-49. PROPOSED ASSEMBLIES EXCEED THIS; SEE "`"'"°` <Nrtn pD cxgHO[.N.alR Rnbxs,aR D[,[YbxO ixnY B[tnnD[OblR BY uceN�[us pro 0 Mgf10ANRLo xl4vaa[c[BY DTN[Rv [°,DN NRclwlP[l1bN O 1MA vBw[R B A INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW COMPLIANCE Cl-PART AT BOTTOM OF THIS SHEET. INSTALLATION BY CONTRACTOR. 450.THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR 11. SEE MECHANICAL SCOPE NOTES ON SHEET A9 FOR HVAC BID THIS OCCUPANCY R-3. 3. IN ACCORDANCE WITH R503.1.1.2 EXISTING CEILING,WALL, OR REQUIREMENT OUTLINES. FLOOR CAVITIES EXPOSED DURING CONSTRUCTION OF AN 12. SMOKE AND CARBON MONOXIDE DETECTORS TO BE PROVIDED NOTES 10. INTERCONNECTED SMOKE DETECTOR ALARMS SHALL BE ALTERATION NEED NOT MEET THE REQUIREMENTS OF THE BY CONTRACTOR; MUST COMPLY WITH UL 268,7th EDITION. PROVIDED IN CONFORMANCE WITH 'FIRE CODE'1103.8 AND ECCNYS, PROVIDED THAT THE EXPOSED!CAVITIES ARE FILLED w/ CARBON MONOXIDE DETECTION EQUIPMENT MUST BE INSULATION. PROVIDED IN CONFORMANCE WITH 'EXISTING BUILDING CODE' SHEET No: SECTION 804, IF NOT ALREADY PRESENT IN THE BUILDING. 4. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS MUST �� CONFORM TO SECTION R404.1:ALL NEW FIXTURES WILL CONTAIN HIGH-EFFICIENCY LAMPS. SHEEP 2 OF 22 WINDOW & DOOR SCHEDULE, ENERGY CODE COMPLIANCE HODGES U-FACTOR/R-VALUE SHGC RESIDENCE ID ASSEMBLY MAKE/MODEL DIMS HARDWARE NOTES QTY ECCNYS PROPOSED ECCNYS PROPOSED 410SOUND ROAD ESCAPE WINDOW e MARVIN UC3240 33"x 40" PER OWNER LOW E2,TEMPERED 1 0.32 0.30(PASS) 0.40 0.28(PASS) GREENPORT,NY 11944 AWNING WINDOW MARVIN UCA3214 33"x 14" PER OWNER LOW E2,TEMPERED 3 1 0.32 0.30(PASS) 0.40 0.28(PASS) © OVAL FIXED WINDOW CUSTOM IRREG. - LOW E2,TEMPERED;REFURB.OR REPLACE 1 `* - ** - DO AWNING WINDOW MARVIN UCA3456 35"x 56" PER OWNER LOW E2 2 0.32 0.30(PASS) 0.40 0.28(PASS) TRUE O NORTH CASEMENT WINDOW MARVIN UCA3654 37"x 54" PER OWNER LOW E2, NOTE HANDING ON ELEVS 4 0.32 0.30(PASS) 0.40 0.28(PASS) 0 CASEMENT WINDOW MARVIN UCA3660,MULLED 37"x 60" PER OWNER LOW E2, NOTE HANDING ON ELEVS 4 0.32 0.30(PASS) 0.40 0.28(PASS) © CASEMENT WINDOW MARVIN UCA4040,MULLED 41"x 40" PER OWNER LOW-E2, NOTE HANDING ON ELEVS 3 0.32 0.30(PASS) 0.40 0.28(PASS) PROTECT O NORTH (27.52°) FIXED CLERESTORY MARVIN UCAP9620 97"x 20" PER OWNER LOW E2 1 0.32 0.30(PASS) 0.40 0.28(PASS) TAX MAP N0.1000-35:1-i6 CASEMENT WINDOW MARVIN UCA2640 27"x 40" PER OWNER LOW-E2,NOTE HANDING ON ELEVS 1 0.32 0.30(PASS) 0.40 0.28(PASS) CASEMENT WINDOW MARVIN UCA2032 21"x 32" PER OWNER LOW-E2, NOTE HANDING ON ELEVS 2 0.32 0.30(PASS) 0.40 0.28(PASS) # ISSUE/REVISION DATE KO CASEMENT WINDOW MARVIN UCA2460, MULLED 25"x 60" PER OWNER LOW-E2, NOTE HANDING ON ELEVS 3 0.32 0.30(PASS) 0.40 0.28(PASS) .00 REVISED FILING SET-ADDITION 10.28.2024 © FIXED CORNER WINDOW MARVIN UCACNR 21"x 32" PER OWNER LOW-E2, LEFT AND RIGHT LEGS 1 0.32 0.30(PASS) 0.40 0.28(PASS) - WINDOWS ARE MARVIN ULTIMATE SERIES,ALUMINUM-CLAD,2 EXTERIOR COLORS(EXISTING HOUSE+ADDITION),WHITE INTERIOR - WINDOW SIZES LISTED ARE NOT CONFIRMED.SUBMIT A LIST OF ROUGH - SIZES LISTED ARE NOMINAL SO CONSULT MANUFACTURER DATA FOR ROUGH OPENINGS&ACTUAL UNIT DIMENSIONS OPENINGS AND PROPOSED WINDOW SIZES PRIOR TO PURCHASE FOR DRAWN BY:J.LACHAPELLE - PROVIDE TEMPERED IGU IN ALL WET AND HAZARD CONDITIONS - SEE A20 FOR WINDOW WALL DATA OWNER/ARCHITECT REVIEW. INCLUDE ACCESSORIES AND OPTIONS FOR a- COMPLY w/R310 FOR EMERGENCY EXIT OPENINGS **R402.3.3 EXEMPTION TAKEN FOR<15 SF WINDOW AS INDICATED EACH WINDOW FOR OWNER CONFIRMATION. CHECKED BY:J.LACHAPELLE NOTE:THIS IS AN 11"x 17"SHEET FRONT ENTRY DOOR b JELD-WEN ARCH'L COLL. 36"x 80" ENTRY,DEADBOLT LH,SOLID CORE 2-PANEL 1 0.32 0.29(PASS) DRAWINGS MAYBE PRINTED NOT TO SCALE FOYER CLOSET DOOR EXIST. 48"x80" EXIST. DBL, LOUVERED VENT 1 LaChapelle Architecture PLLC FOYER DOOR' EXIST. 36"x 80" EXIST. LH,GLAZED 1 P.O.Box 1251 ® BASEMENT DOOR RBS/MASONITE 30"x 80" PASSAGE LHR,SOLID CORE 2-PANEL 1 Mattituck,NY 11952 (646)251-5058 jake@lachapeilearchitecture.com BEDROOM 1 DOOR RBS/MASONITE 30"x 80" PRIVACY RHR,SOLID CORE 2-PANEL 1 © LINEN CLOSET DOOR RBS/MASONITE 16"x 80" PASSAGE RHR,SOLID CORE 2-PANEL 1 BATH 1 DOOR RBS/MASONITE 30"x 80" PRIVACY LH,SOLID CORE 2-PANEL 1 ��FtED A& ® BATH 1 CLOSET DOOR RBS/MASONITE 20"x 80" PASSAGE RHR,SOLID CORE 2-PANEL �5 <_ CH,gA y�A ;s�4 0 90 LIBRARY d RBS/MASONITE 60"x 80" PRIVACY LH,SOLID CORE 2-PANEL 1 ' 10 PORCH DOOR° CURTAINWALL MFR. 30"x 80" ENTRY, DEADBOLT RH, PER CURTAINWALL MFR. 1 0.32 <0.32(PASS) 0.40 <0.40(PASS) 11 PORCH SCREEN DOOR CUSTOM 60"x 80" PRIVACY RHR,DBL WOOD 2-PANEL,SCREEN INFILL 1 A �`e- 12 SLIDING KITCHEN DOOR -d NANAWALL CERO III 136"x 84" PER OWNER X2R X1L,ALUMINUM,TEMPERED GLZ. 1 0.32 <0.32(PASS) 0.40 <0.40(PASS) �TF 033930��0 13 ATTIC ACCESS DOOR EXIST. 30"x 48" EXIST. HOLLOW CORE WOOD 1 OF 14 SLIDING CLOSET DOOR RBS/MASONITE 30"x 80" MORTISED FINGER PULL SOLID CORE 2-PANEL,JOHNSON 1500SC 1 15 BEDROOM 2 DOOR RBS/MASONITE 30"x 80" PRIVACY RH,SOLID CORE 2-PANEL 16 BEDROOM 3 DOOR RBS/MASONITE 30"x 80" PRIVACY RH,SOLID CORE 2-PANEL 1m T "n°�' 17 BDRM 2 CLOSET DOOR RBS/MASONITE 18"x 80" PASSAGE RH,SOLID CORE 2-PANEL 1 18 BDRM 3 CLOSET DOOR RBS/MASONITE 18"x 80" PASSAGE RH,SOLID CORE 2-PANEL 1 SCHEDULES 19 SLIDING BATH 2 DOOR RBS/MASONITE 30"x 80" PRIVACY SOLID CORE 2-PANEL,JOHNSON 1500SC 1 PATIO FRENCH DOOR MARVIN ULTIMATE 60"x 80" ENTRY, DEADBOLT RHR,LOW-E2 1 0.32 0.29(PASS) 0.40 <0.40(PASS) SHEET NO: n-PROVIDE LARSON GLAZED VENTED STORM DOOR AT NEW EXTERIOR DOORS �� 0-NANAWALL CERO III 2-PANEL GLAZED SLIDING SYSTEM,X2R/X1L CONFIGURATION,TRIPLE IG,LOW E x2,AIR FILLED;CUSTOM'RAU COLOR TO MATCH WINDOW EXTERIOR COLOR d-PROVIDE TEMPERED IGU IN ALL GLAZED DOORS,SIDELITES,AND HAZARD CONDITIONS SHEET 3 OF 22 STRAPPING DETAILS CONSTRUCTION NOTES NAILING SCHEDULE HODGES 1. PROVIDE HURRICANE STRAPPING BY SIMPSON OR EQUAL 1. ALL WORK SHALL CONFORM TO THE AF& PA WOOD FRAME 1. NAILINO PER NYS CODE; INCLUDING(5)10d NAILS AT SILL AND RESIDENCE 2. PROVIDE(8)8d COMMON NAILS IN EACH END OF 14" 20 GA. CONSTRUCTION MANUAL 2015 HIGH WIND EDITION PLATE OF ALL 2x6 STUDS 410 SOUND ROAD GALVANIZED STRAP FOR LATERAL/SHEAR CONNECTIONS AT 2. DESIGN LOADS=AS FOLLOWS: 2. USE GALVANIZED FASTENERS FOR ALL FRAMING GREENPORT,NY 11944 RAFTER/ROOF-TO-WALL,WALL-TO-WALL,AND LIVE LOAD: PER TABLES R301.5&R301.6 3. USE 6d NAILS @ 12"O.C. FOR EXTERIOR SHEATHING, EXCEPT USE WALL-TO-FOUNDATION CONNECTIONS IN CONFORMANCE w/ DEAD LOAD: PER R301.4 8d NAILS @ 4" O.C.FOR PERIMETER OF EACH SHEATHING SHEET TABLE 3.3b OF LATEST EDITION OF WOOD FRAME SNOW LOAD:20 PSF GROUND SNOW LOAD PER FIG. R301.2(6) CONSTRUCTION MANUAL(WFCM)FOR 120 MPH FASTEST WIND WIND EXPOSURE CATEGORY'C' FOR 130 MPH 3 SECOND GUST ROOF FRAMING O SPEED PER R301.2.1.4&FIG. R301.2(5)A RAFTER TO TOP PLATE TOE-NAIL 3 PER RAFTER TRUE CLG JOIST TO TOP PLACE TOE-NAIL 3 PER JOIST NORTH LOCATION LIVE DEAD DEFLECTION LIMIT CLG JOIST TO PARALLEL RAFTER FACE-NAIL 3 EACH LAP 1ST FLOOR 40 PSF 12 PSF L/360 CLG JOIST LAPS OVER PARTITION FACE-NAIL 3 EACH LAP 2ND FLOOR 40 PSF 12 PSF L/360 RIDGE STRAP EACH END 2 EACH END PROJECT O ROOF ROOF DECK 40 PSF 15 PSF L/360 BLOCKING TO RAFTER TOE-NAIL 2-8d EACH END NORTH 7.52 27.52°) • ASSEMBLY ROOF 20 PSF 15 PSF L/360 RIM BOARD TO RAFTER END-NAIL 2-16d EACH END TAX MAP NO.100035:1.16 FOUNDATIONS& FOOTINGS WALL FRAMING # ISSUE/REVISION DATE 1. ASSUMED SOIL BEARING CAPACITY= 1,500 PSF TOP PLATE TO TOP PLATE FACE-NAIL 2-16d PER FOOT 2. CONCRETE TO BE 3,500 PSI @ 28 DAY TEST; USE GALVANIZED TOP PLATES AT INTERSECTIONS FACE-NAIL 4-16d EACH SIDE .00 REVISED FILING SET-ADDITION 10.28.2024 OR S.S. REINFORCING THROUGHOUT STUD TO STUD FACE-NAIL 2-16d 24' O.C. 3. NEW FOOTINGS TO REST ON UNDISTURBED EARTH,WHERE HEADER TO HEADER FACE-NAIL 16d 16" O.C. CONFIRMED TO BE FULLY INORGANIC. EXCAVATE AND REPLACE TOP OF BOTTOM PL TO STUD END-NAIL 2-16d PER 2x4 WITH 6" CLEAN FILL OR BANK RUN WHERE DEEMED NECESSARY. 3-16d PER 2x6 FLOOR .4-16d PER 2x8 ASSEMBLY FRAMING BOTTOM PLATE TO FLOOR JOIST DRAWN BY:J.LACHAPELLE 1. FRAMING LUMBER TO BE DOUGLAS FIR/LARCH STAMPED BAND JOIST, END JOIST, OR CHECKED BY.J.LACHAPELLE STRUCTURAL GRADE NO. 2 OR BETTER,2x6 FRAMING TYP. BLOCKING FACE-NAIL 2-16d PER FOOT NOTE:THIS ISAN11"x17"SHEET 2. SHEATHING TO BE APA-RATED, EXPOSURE 1 DRAWINGS MAY BE PRINTED NOT TO SCALE 3. SUB-FLOORING TO BE APA-RATED, EXPOSURE 1, 'WARMBOARD' FLOOR FRAMING WHERE INDICATED JOIST TO SILL,TOP PLATE LaChapelle Architecture PLLC M 4. AT HEADERS OVER 6' PROVIDE DOUBLE UPRIGHTS;AT HEADERS TO GIRDER TOE-NAIL 4-8d PER JOIST P.O.Box 1251 PLUMBING RISER D I AG RA OVER 9' PROVIDE TRIPLE UPRIGHTS BRIDGING TO JOIST TOE-NAIL 2-8d EACH END Mattituck,NY 11952 5. HEADERS TO BE 2x8 MINIMUM OR AS INDICATED BLOCKING TO JOIST TOE-NAIL 2-8d EACH END J 4"CAST IRON 6. PROVIDE DOUBLED FRAMING AT ALL OPENINGS INCLUDING (646)251-5058 jakeC�?lachapellearchitecture.com r -EXTENDER BLOCKING TO SILL/TOP PLATE FACE-NAIL 3-16d EACH BLOCK STAIRS, ETC. LEDGE STRIP TO BEAM FACE-NAIL 3-16d EACH JOIST BATHROOM 2 I 7. PROVIDE SOLID BLOCKING AT ALL FLOOR JOISTS AND ROOF JOIST ON LEDGE TO BEAM FACE-NAIL 3-8d PER JOIST WALL-MOUNT RAFTERS AT MAX.8'-0', PROVIDE 2' SPACE FOR AIR TUB LAV ISHOWE BAND JOIST TO JOIST END-NAIL 3-8d PER JOIST RED ARC TOILET ; ; CIRCULATION AT ROOF ti y J BAND JOIST TO SILL/TOP PLATE TOE-NAIL 2-16d PER FOOT C'� \,N A10 ---J i i `4"CAST IRON l EXTENDER [L F 1] ROOF SHEATHING 2ND FLOOR STRUCTURAL PANELS 8d TABLE 3.8 "• DIAGONAL BOARD SHEATHING: it 1"x6" OR Tx8" 2-8d PER RAFTER. s � r------------ I BATHROOM 1 1"x10" OR WIDER 3-8d PER RAFTER > o O —.-i i i KITCHEN 9T I FOF NEB WALL-MOUNT DISH WASHER CEILING SHEATHING HOWERI LAV ; SINK GYPSUM WALLBOARD COOLERS 5d 7" EDGE I TOILET I 10" FIELD , I I STANDPIPE I WALL SHEATHING LMCX"R1Biq"RMIXsiggx[W"PX[q"cU.x"q¢mqXOlxe ggME"rc"P IncNMEt¢ STRUCTURAL PANELS 8d TABLE 3.9 X ��TMu�a ^"^rX"rX=X ".a ¢gP SPX"�egP�`e 1ST FLOOR FIBERBOARD PANELS "¢e REPLACE 4"HOUSE TRAP 7/16",25/32" 8d 3"EDGE 6" FIELD NAILING &STRAPPING USE PEX TYPE W ONLY LAUNDRY TO SEPTIC PARTICAL BOARD 8d TABLE 3.9 FOR WATER SUPPLY CLOTHES NEW BACKFLOW PREVENTER WASHER FLOOR SHEATHING STRUCTURAL PANELS <1" 8d 6" EDGE SHEET NO: 12" FIELD 4 STRUCTURAL PANELS >1" 10d 6" EDGE 12" FIELD BASEMENT SHEET 4 OF 22 SCTM:1000-35.-1-16 RUNOFF.VOLUME-ADDITION: RUNOFF VOLUME-NEW ACCESSORY GARAGE: i" ODGES ZONE R-40 2"x(6734124)SF=133 CF RUNOFF 2"x 386 SF EXIST.ROOF AREA=64 CF RUNOFF CODE EXISTING PROPOSED COMMENTS REFERENCE 133 CF=995 GALLON DRY WELL,OR 64 CF=479 GALLON DRY WELL,OR RESIDENCE LOT INFORMATION: V=Tr r2 h V=Tr r 2 h PROPOSED 386 SF 410 SOUND ROAD LOT AREA(SF) 40,000 10,772 NO CHANGE NONCONFORMING §280 ATT.3:1 133 CF=TT x 4 x h 64 CF=Tr x 4 x h ACCESSORY GARAGE GREENPORT,NY 11944 LOT WIDTH F 150 75 NO CHANGE NONCONFORMING h=10.6'TALL h=5.1'TALL UNDER SEPARATE FILING LOT LENGTH(FT) 175 143.41 NO CHANGE NONCONFORMING THEREFORE PROVIDE(2)4'0 x 6'TALL RINGS THEREFORE PROVIDE x 6'TALL RING EXISTING HOUSE AREA(SF) -- 868 NO CHANGE -- FRONT STOOP AREA(SF) -- 54 NO CHANGE -- GENERAL STORMWATER NOTES: GARAGE AREA SF -- 312 386 -- -50SF SHED ®, O -INSTALL DRY WELLS MIN.10'FROM HOUSE REAR ADDITION SF -- 87 532 INDICATED IN 1992 , SCREENED PORCH -- 0 141 -INCLUDE LEAF AND SEDIMENT SUMP TRUE SURVEY REMOVED NORTH BACK DECK AREA SF -- 58 124 UPSTREAM OF THE DRY WELLS PREVIOUS TO THIS � SHED -- 0 NO CHANGE PREVIOUSLY REMOVED ^, APPLICATION TOTAL COVERAGE SF 1,379 2,105 2,154 ALLOWED DEMOLISH EXISTING O 20% 12.80% 19.54% CONFORMS §280-124 ACCESSORY GARAGE NORTH PROJECT SETBACKS: UNDER SEPARATE FILING / (27.52,) FRONT YARD F 35 8.1 NO CHANGE NONCONFORMING §280-124 (312 SF) s \ TAX MAP NO.100035:1.16 SIDE YARD f 10 13.8 NO CHANGE CONFORMS §280-124 o. BOTH SIDE YARDS F 25 42.3 40.1 CONFORMS §280-124 a ISSUE/REVISION DATE REAR YARD FT 35 88.2 71.3 CONFORMS §280-124 / �� % / � � / / / j ri• � .00 REVISED FILING SET-ADDITION 10.26.2024 SEE DWG A16 FOR COMPLIANCE WITH AREA OF OPENINGS IN WALL OF §280-208 PYRAMID LAW ADDITION FACING GARAGE ARE IN CONFORMANCE WITH LIMITS IN BC �� `( ,j j` \ NEW DRY TABLE 705.8 BASED ON FIRE \ / ZZ, \ WELL UNDER DRAWN BY:1.LACHAPELLE SIDE YARD SETBACK SEPARATION DISTANCE / ' / 1 \ GARAGE o \ � LEAF \ FILING CHECKED BY.J.LACHAPELLE REMOVE EXISTING $0 �: SUMP ENTRY PORCH(31 SF) � •'� � � \ ! NOTE:THIS IS AN 11"x 17"SHEET AND ADDITION(87 SF) �Dc3 /' O, d: / `� \ OS` DRAWINGS MAYBE PRINTED NOT TO SCALE 4, 0 2 \\ / I/ \ 35 LaChapelle Architecture PLLC P.O.Box 1251 PROPOSED ADDITION Mattituck,NY 11952 (673 SF)&DECK(124 SF) \\ (646)251-5058 jake@lachapellearchitecture.com jai � � �! l - /•, , I DRIVEWAY ' 24 EXISTING �10 BRED A&, 2-STORY CHAa EXISTING FRONT —� RESIDENCE Ft STOOP TO ° �9 (868 SF) \ ;��1 Cc, C �� C� c� \ �EMOVE ISTING REMAIN(54 SF) 59 ' A a BIIACK D 58 SE} 6 2 \ a / ,/ APPROX.LOC. N� 0,� O� TRUE O $1 EXISTING SIDE YAR y D ETBACK F NORTH G2 /,•� LEACHING RING OF NEB P ALLOWABLE GROSS SQUARE FOOTAGE CALCULATION: 2,100 SF ALLOWED +12.5% OF(10,772 SF-10,000 SF) =2,196.5 SF ALLOWED • M"Mo :° o° °e�a"�°mP " PROJECT NORTH O \ SCTM:1000-35.-1-16 (27.52°) /' 0 ZONE:R-40 / 1�3a CODE PROPOSED COMMENTS SITE PLAN GROSS SQUARE FOOTAGE: DIMENSIONAL DATA IS OBTAINED FROM SURVEY BY PJM /'' EXISTING 1st FLOOR(GSF) -- 868 LAND SURVEYING, PLLC DATED 10/18/2023,WITH OVERLAY , p,0 EXISTING 2nd FLOOR(GSF -- 670 OF PROPOSED WORK BY LACHAPELLE ARCHITECTURE PLLC. S6,L°2,8 ADDITION 1st FLOOR(GSF) 532 CEILING HEIGHT< 15' SHEET NO: OSITE PLAN / 1 TOTAL COVERAGE(GSF) 2,196.5 2070, CONFORMS.§280-207 �� SCALE: 1/16" = 1'_0"' SHEET 5 OF 22 HODGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 r------------------------------ 1 I 1 I ® O I TRUE, NORTH DEMOLISH PARTITION AND MILLWORK PROJECT O 25'-5" i i NORTH (27.52') I I - I I TAX MAP NO.100035:1.16 L--------''---------- ----------J j # ISSUE/REVISION DATE j DEMOLISH EXISTING `. —•—•—•—• ......—.—•—.—o—•—•—•��-• —•—� —� -� .00 REVISED FILING SET-ADDITION 10.28.2024 1 GARAGE UNDER --------------------- SEPARATE FILING � 1 I 1 I - EXISTING CONCRETE I DRAWN BY:1.LACHAPELLE BLOCK FOUNDATION Fi DEMOLISH CONCRETE I WALL AT ENTRY — ....... - -'—' — —°—.—.—.— a BLOCK FOUNDATION CHECKED BY:1.LACHAPELLE I _ WALL AND FOOTING AT I NOTE:THIS IS AN 11"x 17"SHEET ———— 1 I L i^`I EXISTING CRAWL SPACE I DRAWINGS MAY BE PRINTED MOTTO SCALE — — EXISTING OPENING I NO DRIVING ZONE — TO CRAWLSPACE I ABOVE EXISTING UP 1 REMOVE HOT WATER r--------- SEPTIC LINE AND LaChapelle Architecture PLLC i HEATER, FURNACE, FUEL i CESSPOOLS P.O.Box 1251 1 LINES,PIPING, FLUES I Mattituck,NY 11952 EXIST.2x4 j UNFINISHED — — — — — — — — — — — — —i— — — — — — — — — — — — — (646)251-5058 jake@lachapellearchitecture.com JOISTS @ 16"O.C.j BASEMENT � _ I ----------------- Cl) UNDERSIDE JOISTS BRACE FLOORS, i LOCATE SEPTIC LINE WITH HAND-DUG EL. +X'-x° 1 REMOVE BRICK FLUE I TEST HOLES,50 AS TO AVOID ED �R AR '(DAMAGE DURING EXCAVATION: C BRACE STRUCTURE, i MAP SEPTIC LINE AND CESSPOOLS ON SAWCUT OPENING FOR NEW i SITE PLAN AND SUBMIT TO OWNER �C� _ OPENING TO CRAWSPACE i FOR RECORD PRIOR TO '1 EXISTING(2)2x8 BEAM i COMMENCEMENT OF EXCAVATION IL---------------------- --- I N �.—�� L----J EXISTING(3)2x8 GIRDER A EXISTING CONCRETE BLOCK FOUNDATION EXCAVATE FOR OF NE`N SAWCUT OPENING FOR ADDITION LARGERWINDOW, Tw ouvANO—INST-1.ov![g [ANDcl wSiM PaD.fNRov Kx M4[ .ncxD[nNO[ [D ,�fM[D.�, 11TBI�..a[DB EXCAVATE FOR �« o „pa „m—ON,�..a[�.D, .�..� iDw.DDmDroT.n.�[[T,.DD[..;>��°°,��[;P[��o�,�;.�°Rai WINDOW WELL TRUE EXISTING n NORTH (27.52`) BASEMENT PLAN EXISTING WALL TO REMAIN � SHEET NO: PROJECT O EXISTING BASEMENT PLAN DEMOLISH WALL ISO= NORTH A g 1 SCALE: 1/8" = T-0" / SHEET 6 OF 22 HODGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 P aaa�aaaaaaaa�aaaaaaamaaaaaaa�aaaa TRUE O DEMOLISH DEMOLISH EXISTING NORTH EXISTING FLUE BATHROOM FIXTURES AND FINISHES j OJ PROJECT 0 ,1 a CT 25'-5" 10'-4" n NORTH (27.52') u 1 lI _ TAX MAP NO.100035:1-16 --------------- # ISSUE/REVISION DATE I rr I i l i ., ,III III j,l II III I�I BATH 1 DEMOLISH EXISTING it 11 1, .00 REVISED FILING SET-ADDITION 10.28.2024 II I BEDROOM I _ DEMOLISH EXISTING GARAGE UNDER 1 j j I IJ°t �. 1 i-� 1 { { 1 SEPARATE FILING ' I - ' r , -{ DECK AND ADDITION STAIR: II II it Illy �III� II j1'�I i' I�I�i r h 1 - k I j i 1 I , I 1 I -� ! 11 I - II im ��[ .I II� ! ;� I ' I_-1 1 ; , 1;° LAUNDRY 1 fIeI 4'R 7- ( I I I � I � � i 1e� - - - { I jm 4 III I i. � 11 I l i I_ � I i I i e 3T @ 9" DRAWN BY:J.LACHAPELLE J_ -- R CHECKED BY:1.LACHAPELLE _-DN ---_ COA S � � 7� I L� I { � � f �1 � I 1 III ' I 1 I ', NOTE:THIS IS AN 11"x 17"SHEET —A - ' —I { _I j 1 I I �.f DEMOLISH HALL TILE DRAWINGS MAY BE PRINTED NOT TO SCALE UP-STAIR: lill ; l �� �ll ';�,11 12R 8�" j I KITCHEN DEMOLISH INTERIOR 13T @ 102" = i:I ;- III I11 llj PARTITIONS AS LaChapelle Architecture PLLC e' P O Box l 51 =; ►�jl � i� ��.�-Ilij �11 � � � Jeer INDICATED 2 LIVING ! I' { a I Ii Maa , 11952 DEMOLISH EXISTING jake@lachapellearchitecture.com KITCHEN CABINETS, (646)251-5058 ake@lachchapellearchitecture.com ='M TILE,FINISHES _ - __ _ DEMOLISH EXISTING DECK DINING III ED Aly LACygA - +o PROTECT EXISTING CHIMNEY REMOVE EXISTING BRACE STRUCTURE PRIOR TO FIREPLACE AND HEARTH REMOVING LOAD-BEARING WALLS; "9j 033930 O� COORDINATE WITH INSTALLATION OF NE`Ny REMOVE(2)EXISTING BAY OF NEW BEAMS WINDOWS rasoRntt x"n�wsrRun[xro[s�msv� x"R`unw.mna,axou n en�'nr ieux"omie�rrtinsr�`u�n ancntrecruaoxioLLims�aartn vw.r xos xe use foR�q MfIgWRxRUi1x[wmR[xntoxl�[tn b[tgcl4p[LL[pPtx c�'NRL Pu4"r5� O MTAOMIm]n 1ARwV[LLC TRUE NORTH EXISTING . (27,52') FIRST FLOOR PLAN EXISTING WALL TO REMAIN SHEET NO: PROJECT OEXISTING FIRST FLOOR PLAN DEMOLISH WALL E2203 NORTH �� SCALE: 1/8" = T-0" SHEET 7 OF 22 HODGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 r------------------------------------------------- I I I I I I I I I I NORTH1 I I I I I I I ® b I I I PROJECT O 25—5� NORTH (27.52') I 1 I I I I TAX MAP NO.100035:1-16 I I II Itl III II I. li I 11 Lr III III I� I IIIIIII I I III,,iIIII,I �L'F��� I' �G► o L-----------------------------�--__— ---_--J — p ISSUE/REVISION DATE III I I III ;IIII I "III �� DEMOLISH EXISTING DEMOLISH EXISTING III (IIII 'III III III �� t N `i t iJ�'3.�, .00 REVISED FILING SET-ADDITION i0.28.2024 BATHROOM FIXTURES GARAGE UNDER BEDROOM 2 I`+l It{ t art,' ;I' AND FINISHES SEPARATE FILING jII;Ijlull tll11l li I BATH2 '191 I'I IIIII!t ) �>{.�'' 7 0 IGI 'I t �' IIII IIII IIII' I it I� i;'� sa iL �`lo DRAWN BY:J.LACHAPELLE IIII I IIIIIIII llt�'i .11l���. i`'?�� +phi I>a� CHECKED BY:J.LACHAPELLE bN NOTE:THIS IS AN 11"x 17"SHEET MIS --__--,.'I"=_ - -I - _ - - DRAWINGS MAYBE PRINTED NOT TO SCALE ATTIC —� REMOVE EXISTING iv I'' II II dllllrllil r'I II �, I'I I Illj'I 11 II IIIII II a SKYLIGHT III I'I'.' IIIII 'i I' II III, IIIII III LaChapelle Architecture PLLC ',I III II jl I'I i' Ij P.O.Box 1251' III li I'I I I I jh IIIII IIII Ii II III i I' I I i t I I , IIII Mattituck,NY 11952 IIIII ;i IIIII'Iii II II IIII IIII' II f III I I I LI IIIII' (646)251-5058 jake@lachapellearchitecture.com I I�I I II'. ; •1 I'll �I ilt ' ffI I i IIIII I' I ' I ' i'l 'II' u1 �i IIII;I�IIII I I I' I I llll,i�illlihll I I,IIi IIi,III '�III I I II'll ni lliunli ICI 'IIII BEDROOM 3 IIII llllii II ! Ij II . „I � �FtE D ARc i REMOVE CLOSET WALL AlII �i fI '�I �;�I II!li i l li ill lilil'I'I �� COAC"gp Al .II III i'I �3 it 11 it 'I li III II IIi a III ((� ��� �ok I I I ui'I I I nl�I I l i i t I I I , i I III �II' I I! IIIII li I I I I IIi I III � � � I I �iI IIII I i III III IIII IIII I. IIII I ( IIIII !I, IIII I I Illli IIII �►_ 't, I! DEMOLISH EXISTING FLUE �TFO 10 N Tgs"PPptl6 pAH lxslnuNLul"ie[FMlAn gpv[gfvOv 4CxAvell[ _ vmnwHCxrtpPx[nnm."p "t crtat vp[,ilns OVDwpa LNYxm e[IR[n¢Y oiiXCv VMLILSioA OixlA MNLCIS aWRpx�i"ixp nx"1[tt BY"Ix["vuRS["I miIALWS"CLLL�Ktwrt[ttW[ttPUG� �O wwnmxr mu vsxnv[uc uxxRLcrvx[vucx TRUE NORTH EXISTING (27.52°) SECOND FLOOR PLAN EXISTING WALL TO REMAIN O JECT SHEET NO: PRO O EXISTING SECOND FLOOR PLAN DEMOLISH WALL ��mZ3 NORTH SCALE: 1/8" = T-0" A8 SHEET 8 OF 22 I MECHANICAL ENERGY CODE COMPLIANCE H®D G ES 1. PROVIDE(2))DUCTED HEAT PUMP SYSTEMS,SIZING TO BE CONFIRMED U-FACTOR/R-VALUE RESIDENCE BY MECHANICAL INSTALLER. ID ASSEMBLY ECCNYS PROPOSED 410 SOUND ROAD PROVIDE QUOTATION FOR 3 TON GREENPORT,NY 11944 HEAT PUMP AIR HANDLER AT 1 EXIST.4"EXTERIOR PARTITION 3.5"MINERAL WOOL WHERE EXPOSED 14 BASEMENT CONNECTED TO 3 TON 2 NEW 6"EXTERIOR PARTITION 2"SPRAY FOAM+3.5"MINERAL WOOL 20 29'(PASS) CONDENSER AT SOUTH SIDE OF HOUSE,2.5 TON HEAT PUMP AIR 3 NEW 4"INTERIOR PARTITION SOUNDBATT MINERAL WOOL AS INDICATED HANDLER AT ATTIC STORAGE AT HYBRID HEAT PUMP HOT WATER SECOND FLOOR CONNECTED TO 2.5 HEATER,VENTED TO BASEMENT - CRAWL SPACE WALL 2"XPS RIGID FOAM 10 10(PASS) TRUE NORTH O TON CONDENSER AT SOUTH SIDE INSTALL FRAMING AND - EXIST.ROOF 5.5"MINERAL WOOL WHERE EXPOSED 22' OF HOUSE. PROVIDE ALL PLYWOOD SUBFLOOR AT NEW ROOF 7.5"SPRAY FOAM 49 52 PASS ACCESSORIES, INCLUDING COPPER AREA OF FLUE REMOVAL 1 - (PASS) PROJECT 0 LINESETS, DUCTING, DAMPERS, 5_5 NORTH INSULATION,CONDENSATE PROVIDE BENTONITE WATERSTOP IN CONTINUOUS (27.52`) PUMPING,COMMISSIONING, ETC. © © STRIP BETWEEN EXISTING AND NEW CONCRETE,TYP.; � � TAX MAP N0.1000.35:1-16 NEW 2'�S TEE L BENTOSWELL BY OCM OR S1M.;DOWEL PER DETAIL 3 2. PROVIDE MANUAL J AND S C CALCULATIONS. �`-°_ -_ EXISTING OPENING TO # ISSUE/REVISION DATE - COLUMN, .- � 1 CRAWLSPACE;NEW HEADER COORDINATEWITH j PROVIDE(1)ACCESS HATCH _ •—•—•—• •—�—o—�—�—•—• .00 REVISED FILING SET-ADDITION 10.28.2024 BEAM LOAD ABOVE; - -'- -'- - 3. PROVIDE 13 CF PER MINUTE I --CIP FOUND.TYP.;SEE A23&A24 TO CRAWL SPACE UNDER MECHANICAL EXHAUST SAWCUT SLAB FOR j - - -- - - - - - - --- MECHANICAL ---------, -.----'------;- --� SCREENED PORCH NEW 24"x24"x12" _ . ... ,i I �� - - VENTILATION FOR CRAWLSPACE IN I r -r-r -r T-r--r r r�1 -r........ - - -I 2x8 JOISTS 16 O.C. REINFORCED - - - _.--- - "-•-•-' °- -'-'_. I I I I I I I I I II I I I I I I I' l I „ CONFORMANCE w/R408(1CFl 50SF), 1 1 1 1 1 I I 1 1 1 1 I II 1 I 1 1 1 1 I` III 10 x10"CONCRETE PIER ON CONCRETE I I I I I I I I I I I I I f I „ „ „ IN LIEU OF PERIMETER VENTS I 1 1 1 1 1 1 1 1- I 1 1 1j I t i i i i i( I 24 x24 x12 SQ.FOOTING DRAWN BY:J.LACHAPELLE FOOTING j L 1NTYP.; REINFORCE PER A24 I I I. I I -' CHECKED BY:J.LACHAPELLE 4.PROVIDE MAKE-UP VENTILATION AIR I I t I I 1 I I ICI I I y I I I I I I I I DETAILS _ AT KITCHEN. I 16'- " 111 r6"I 9„` �„ NOTE:THIS IS AN 11"x 17"SHEET I I I I I 1 , I L�MLCROLLAM 1 x LVL BY WEYERHAEUSER DRAWINGS MAY BE PRINTED NOT TO SCALE UP __ --i-t-i--I-�?-t� ; -I LaChapelle Architecture PLLC 11 1----1----t-t 1 -------------- - ' SEE A24 FOR VAPOR -- -j SC I t I I I I I I I- I I I I I I I ---- `- .... _._o_•-•-•-.-•-.-.-._._._._._. I I I I I I q%)I� I I I I I.: `1v BARRIER AT CRAWLSPACE P.O.Box 1251 1 I I I I I I I I IYI I I I I C I , ---- ---JI I � Mattituck,NY 11952 EXIST.2x4 UNFINISHED -1 —L L L L L 1_1�1� 1 L` �I 1 C1_ s� FLOOR AND OTHER DETAILS c•i1v 1 I I I I I I I 1 I I I I I I I (646)251-5058 fake@lachapellearchitecture.com JOISTS @ 16 O.C.- BASEMENT I I I I I I I I 1 11 -------- PROTECT11 1 b� EXISTING _ _ _ _ _ _ _ _ 1 _ _ _ _ _ _ _ _ I I LS A E I I I I 1 I I N o I I I I I J____� I I I I I I ------ " l i CO PERIMETER VENTS AT 1 - 1r-r � �"" , UNDERSIDE JOISTS I I 1 I 1 II I I I I i t -_�I I , 2x8 JOISTS @ 16 .O.C� ENTRY CRAWLSPACE 1 r-I-r-r-rFib, T-r-rr-r_ ------ EL. +x,_x I I I I _ _�I I I I I I I I it I w RED q - 1 L_j9.16 1 ------ .( RC r I I Ito 1 .' I I I I 1 1 ,I . ------ f 1 1 1, r2z&LEDGER - 5 �c�P`OHga «a I 1 1 11�1- L2x8PT JOISTS a I I I I I I U, I-- _ . . @- 1 m � 1 I 1 I 1 1 I IcpI I I I I '1 ------ r1 '(2)2X10 P.T. BEAM QN_'� D n i I I I I I I I 1co1 I I I I IT I 1 i I I I I I I I I I I I I I I ---- .T.-POSTS.�.A : I I I r T-r r--T----r---r--T----r---r----T-- r I------- I I © - SEE A25 FOR DECK DETAILS cp !a REINFORCE AT BASEMENT COLUMN FOR I I -- ------ -- ------- -- -------- �' �c 8'CIP FOUND.TYP.;SEE A23&A24 _ 9 NEW HEARTH AND FIREPLACE STOVE 7'_741" >F 033930 7L INSTALL WINDOW AND ACCESS WELL IN 20'-12' T-42 p' F N E`N CONFORMANCE WITH EMERGENCY 27'-112' ESCAPE AND RESCUE OPENING REPLACE EXISTING HOUSE REQUIREMENTS R310;SEE DETAIL 1/A25 TRAP;SUPPORT OR REPLACE SEE 1/A23&2/A24 FOR PROVIDE 13 CF PER MINUTE EXIST. PIPE TO SETTLING COLUMNS MECHANICAL EXHAUST VENTILATION o po�a` � �� w; �ort £ PLUMBING AND ELECTRIC FOR NEW RING(S)IN REAR YARD NEW OPENING TO FOR CRAWLSPACE IN CONFORMANCEa � � °a WASHER&DRYER;VENT TO GRADE w/R408(1CF/50SF IN LIEU OF TRUE FLOOR ASSEMBLY CRAWLSPACE; NEW PERIMETER VENTS NORTH NEW HE CANTILEVERED OVER HEADER BASEMENT FOUNDATION TO ACCOUNT FOR ❑F FIRE EXTINGUISHER (27.52°) PLAN THICKNESS OF FOUNDATION INSULATION;SEE DETAIL 21A23- O WATER DETECTOR ALIGN NEW FOUNDATION EXISTING WALL TO REMAIN CO SHEET NO: NEW BASEMENT PLAN ACCORDINGLY SC SMOKE+CARBON MONOXIDE DETECTOR PROJECT O DEMOLISH WALL I�la�lll,�lll� NORTH AG SCALE: 1/8" - 11-0�� SMOKE AND CO DETECTORS SHALL COMPLY WITH UL 268,7th ADDITION SHEET 9 OF 22 FIREPLACE STOVE NOTE: SEE A9 FOR PARTITION TYPES H O DG ES 1. PRIOR TO USE INSTALLING CONTRACTOR SHALL EXECUTE(5)BREAK-IN FIRES IN NEW FIREPLACE TO' RESIDENCE AVOID DAMAGE TO FINISHES AND SOAPSTONE 410 HEAT-RETENTION STONES.IF NOT PERFORMED SOUND ROAD CONTRACTOR SHALL REPLACE AND INSTALL NEW GREENENPORT,NY 11944 FIREPLACE AT THEIR OWN EXPENSE. HEARTHSTONE BARI FIREPLACES AVAILABLE THROUGH COZY CABIN STOVE&FIREPLACE,WARRENSBURG,NY (518)623-4349 ® O NEW WOOD PLANK CLERESTORY WINDOW ABOVE; TRUE FLOOR AT BATH 1 SEE ELEVATION NORTH REPAIR EXISTING STAIR: � -REPLACE TREADS AS NEEDED,STRIP AND RESTAIN -PROVIDE NEW ARCHITECTURAL RAILING(10)8"IRON 52_g 11'-7" BALUSTERS#9092R AND WHITE OAK HANDRAIL#6084 25'-5" 15'-9" PROJECT O 2'-9" . NORTH BY JMP WOOD, BROOKLYN, NY (718)303-7777 6'-5" 12'-6" 61-6" 6-9-1 6'-3" EQ. EQ. EQ. EQ BLUESTONE PATIO BY (27.52-) E E OTHERS TAX MAP NO.100035.446 8 ISSUE/REVISION DATE io .00 REVISED FILING SET-ADDITION 10.28.2024 04 ATH 1 I H SCREENED OPENINGS STAIR: O BEDROOM 1 j , , -� a i CJ ` °D 12R @ 81" (141 SF) - EENED P.- w —co 13T 10 3 bo F @ p 11'-114' �bN LIBARY _ U DRAWN BY:J.LACHAPELLE 4-6" C�4THE#f --IL NG=_-�- '�" CHECKED BY:J.LACHAPELLE �Iv COATS DN 1„_ -`o T-10"CE LING I 7-8_ NOTE:THIS IS AN 11"x 17"SHEET _ cnl� ;r 2 19'-7" 1 O 1-O' ¢ DRAWINGS MAY BE PRINTED NOT TO SCALE N — 1 UP 11 N� LaChapelle Architecture PLLC m _ _ M P.O.Box 1251 �9'-411 7--4' - Mattituck,NY 11952 , � NEW WOOD © - 24.5 III WI BB °D (646)251-5058 jake@lachapellearchitecture.com FLOORING DECK CUSTOM SCREENED Lo IN ENTRY `toF—Kr CHEN `'L� 12 �,� DOUBLE DOORS BBB - D � D � --- --- BB �5 �cHgA y�j CO - - --- STEP LIGHTS;SEE A13 FOR Co SWITCHING BBq 54"x 46"TILED HEARTH SET ON 4" 0 1 0 0 o THICK CONCRETE;COORDINATE ALIGN O�/ Q�; Owl (P ............... SHIELDING WITH FLOORING MFR. yT o y0 BARI FIREPLACE STOVE MODEL#8171 BY 6'-11" 11'-81" ol 6-21" 10'-3 "� — 10'-31" 7'41" �OF NE`N HEARTHSTONE; PROVIDE DOUBLE-WALL 14 4 2 1„ 2 2 CONNECTOR FLUE PIPE 24-92 27=1 -2 UPGRADE ELECTRIC SERVICE 52-9 NEW HARDWOOD 4 PLANTER METER&PANEL TO 200 AMP omo"C " =�E,a, � �� FLOORING or" THROUGHOUT HOUSE TRUE NEW NEW 2.0E MICROLLAM 7"x 14" NORTH(27 52°) FIRST FLOOR LVL BY WEYERHAEUSER; BEAR PUN SEE Al FOR SMOKE AND CO DETECTION ON 6x4 POSTS TO SEE Al FOR DETAILED PLAN OF KITCHEN, LIBRARY/SCREENED PORCH,AND BATH 1 FOUNDATION&LALLY COLUMN SHEET N0: PROJECT ONEW FIRST FLOOR PLAN NORTH A10 SCALE: 1/8" = T-0" SHEET 10 OF 22 SEE A9 FOR PARtITION TYPES HODGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 NEW WOOD PLANK FLOOR AT BATH 2 OVAL SOAKING TUB& FILLER TRUE, NEW FIXTURES&FINISHES NORTH THROUGHOUT BATH 2 53-6 25'-5" 28'-1" PROJECT NORTH O 10'-71" 4'-2" 10'-71" (27.52°� 44 2 — 2 '�N\N TAX MAP N0.1000-35:1.16 U!III�IIIIIIIII Jill M C # ISSUE/REVISION DATE I O I CLG. I II I � J SLOPE �Il lli III 7i-4n III .00 REVISED FILING SET-ADDITION 10.28.2024 I IIIIIIIII � � �,� I BE ROOM 2 I� I IIIilIIi!l(IL7 BATH l F!2 ®(106 SI � °� O DRAWN 8Y:J.LACHAPELLE7 CV ��CV CHECKED8 :J.LACHAPELLE 4'-11 NOTE:THIS IS AN 11"x 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE Mrs " ATTIC - IIIIIITIICV III M �II Il�.Ii 1'I�1 I3lInIll II I Ii_�IIIII,iI,I.t hIO:�I,II I�1 I I IIIl�IlIuI1iII ,III IIITII ,I III I IImII�,i I��II111111 IIITII lill IIIIII 111111 111111 Will 111111 Will IIII �N� I WillWillWillM LaChapelle Architect ure PLLC — P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com m .I. EDROOM 3� {i(I I IIjI II III1'IIl ul l ll IlIiII,l IL�;iIIl'a,iIIl�-i1,,---_ III I IIIl�'L3Il�II II 1IIII I"IIIIIIIII lIII..I�IB�I;Il''ilIlIl IlIlI.I CI.iI�I('I'(2IIII IIIi lI 1lIIIIII4II'IIII I1.SS OPE , Fl,iIlI.i) I II! lIi'I III�'I iII 1I1 LII iI I'III'I"III IIIIiI�1' I II I�II II ;�I 11II PATIO PROVIDE CLOSET SHELVING& RODS PER OWNER (320S L�EA�.D qq�,,o c15'3' ' III I l �1I4'- 1 � , K L I I I � I I 119-8 I I I I I I I 13'-4 8'-6 ' 31_6" rN "9j� 033930 �0� 24'-92" 19'-112' 2' OF N EW 7l 53'-6Ir " NEW PLANK WOOD FLOORING NEW FULLY GLAZED THROUGHOUT ALUMINUM DOORS wl "^ ;pro °° �°;°m„w„p °°°°��•��"°wm"^1—Y SCREEN DOOR :,�� ` owm,cMm„ ,� 36"TALL S.S.AIRCRAFT TRUE NORTH NEW mm M CABLE RAILING WITH WOOD SECOND FLOOR TOP RAIL TO MATCH DECK (27.52°) SEE A14 FOR SMOKE AND CO DETECTION MATERIAL BELOW PLAN SEE Alb FOR DETAILED PLAN OF BATH 2 SHEET NO: PROJECT ONEW SECOND FLOOR PLAN NORTH SCALE: 1/8" = 1'-0" All SHEET 11 OF 22 HCDGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 T®NORTH. O REMOVE EXISTING FLUE AND SKYLITE; REPAIR FRAMING,SCREW&GLUE S CONT�2)2 OE MIC SHEATHING,APPLY ICE&WATER j SHIELD,INSTALL ASPHALT SHINGLES IN BY=GUEYERFiA�USER AT LIBRARY EAI/ES NORTH T O THIS AREA TO MATCH EXISTING Z�-- c27.52^> 2x10,FZAFTERS_ 24"_O.C.--_ PROTECT EXISTING FROM BEAM OVER NOOK TO RIDGE - TAX MAP NO.1000.35:1.16 ASPHALT SHINGLE ROOF BEAM:2x4 FRAMING,GLUED& SCREWED al'PLYWOOD SHEATHING; n ISSUE REVISION DATE SEE DETAIL .00 REVISED FILING SET-ADDITION 10.25.2024 -- --- --- --- --- --- -- ---fie-- ---fig I I I I I 1 I I I I I I I I I I I I I I I III �54'_X'54 FPARALLAWPSL POST I I f I I I I I I I I I I I I BY-1'111E_YERHAEUSER=AT END OF - I I I I I I I I I I I I I III t RIDGEBEAM,-EAVE-BEAMS DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE I I I I I I I I I I I I III RIDGE BEAM:2.0E NOTE:THIS IS AN 11"x 17"SHEET ' MICROLLAM_32'z 1.6 LVGBY DRAWINGS MAY BE PRINTED NOT TO SCALE L------- , I I I I I 1 I I I I I I I I t l I I I I I I I I I I I I I l i l �-- -- WEYERHAEUSER LaChapelle Architecture PLLC I I I I I I I I I I I I I I I I I I I I P.O.Box 1251 I I I I I I I I I I I I I I I I I I I i I Mattituck,NY 11952 I I I I I I I I I I I I I I I I I I I I (646)251-5058 jake@lachapellearchitecture.com CONT-(2):2 OE,MICROLLAM14"x I I I I I 181'/RT 6LIOfPQ I I I I I I I II `"tg !LV.L BYVEYERHAEUSER AT` t- 1I I I I I I I III I I I I I I I I ICI ' l l l l l l l l III I l l l l l l l l i l EAVE ED ' Illllllllllllllllllil it- ER qRC I I I I I I I I I I I I I I I I 1 I III I 3"_X ��5 E!_AC I I I I I I I I I I I I I I I I I I I ol I (2)`Z0E_MICROLCAM 114<x_114_LVL Q�f- F i B1�IINEYERHAEUSER w/_1"x 10" ' IIIIIIIIIIIIIIIIIIII t I I I I I I I I I I I I I I I I I I I I STETCHP_LAT Illllllllllllltlllll -- -I--r-��� -r-r I OP NE FLUSH MOUNT 2.0E MICROLLAM 32'x 11 'LVL'=_By VVEYERHAEUSER 2z8 TERS @ 0 C "- --. � _ -MT.— 'OR ILOWloxe"inw eWxnvaWMM AR(nMOerOmRnwMr°nmassoal ximhsxex WxIMY WHIR M.QHTT `�—WOO ° " H„M.—H, -HM -2OE MICROLLAM�a_x�14' VLBY WEY FUSER AT WINDOW -- TRUE NEW NORTH (27.52') ROOF FRAMING . PLAN T SHEET NO: PROJECT NEW O CALEROO F FRAMING SCALE: ING PLAN ONEW ROOF C F FRAMING PLAN NORTH 1-1=16 11116111 SHEET 12 OF 22 HODGES RESIDENCE 410 SOUND ROAD GREENPORT,NY 11944 REMOVE FLUE PROTECT EXISTING — — — --- —=— --- ® O ASPHALT SHINGLE ROOF — — — — — — — — N Rm OL EXISTING CEILING - - - - - - - - - - - - - - - - - - - _ EL. +16'-6 314" SCRAPE AND PAINT — — — — — PROJECT 0 PROTECT EXISTING NORTH EXTERIOR ACCESSORIES -- —— — -- — — — — CHIMNEY; REPOINT AS SECOND FLOOR EA = — NEEDED TAX MAP NO.100035.4-16 EL. +8'-7" 9"FLOOR ASS --t_ —— - -- - _ ADDITION AT REAR EXISTING CEILING ________________ _ - -- —— — — — - OF HOUSE # ISSUE/REVISION DATE EL. +T-10" --- ` .00 REVISED FILING SET-ADDITION 10.28.2024 PAINT ALL EXISTING \ �, `, -_-.:. EXTERIOR TRIM;COLOR PER OWNER OL FIRST FLOOR EL. +0'-0" DRAWN BY:J.LACHAPELLE CHECKED BY.J.LACHAPELLE STRIP AND REPAINT EXISTING CEDAR REPAIR EXISTING DECKAND NOTE:THIS IS AN 11"x 17"SHEET OWEST ELEVATION SHINGLE SIDING PER OWNER'S RAILING AS NEEDED DRAWINGS MAY BE PRINTED NOT TO SCALE 1 SCALE: 1/8" — T-O° SAMPLE(BLUE OR SIM.); REPLACE SHINGLES AS NECESSARY LaChapelle Architecture PLLC P.O.Box 1251 Ma STRIP AND REPAINT EXISTING a 11952 ke@, h j CEDAR SHINGLE SIDING PER (646)251-5058 ake@lacapellearchitecture.com RESTORE OR REPLACE OWNER'S SAMPLE(BLUE OR DETERIORATED WINDOW; SIM.);REPLACE SHINGLES AS REPLACE SIDING,SHEATHING, NECESSARY FLED ARC AND FRAMING AFFECTED BY NEW ASPHALT SHINGLE �� ROT AS NEEDED l _ ROOF,COLOR TO MATCH _p,CHgp� _ EXISTING;GAF UHD OR SIM.OIL EXISTING CEILING EL. +18's3ia., - - - - - - - - - - - - - - - - - - - - - - --- —_ — — _ — — 36"TALL S.S. AIRCRAFT CABLE t `�' It RAILING WITH ��y, o33s� 0 WOOD TOP RAIL SECOND FLOOR — — TO MATCH DECK T�O F N EL. +8'-7" 9"FLOORASS — MATERIAL BELOW EXISTING CEILING — — — — — — — — " - - — — — — - - - - - - - - — — — — — — - - - A'TO D EL. +71-10 — — — — — — — — — USE ACCOY ASTES HOU SUGI BAN FOR ALL EXTERIOR RIOR aKxrtrmuncx"cu�°ac°eniuc porwncmEnmerxacm r°xn"uxrtarnn.nroa - TRIM AT ADDITION mEmior'wvecr a°v°"rxrnm°°cmmexoinc`v"i°,aiv°ien'ienuvl"rn°ieci WEST&SOUTH FIRST FLOOR ' ELEVATIONS \fF - -EL. +O�_0x — — — — — — — — — — — — — — — — - - — — — — — — - - Lml STRIP AND REPAINT EXISTING ACCOYA'TOASTED'SHOU SUGI BAN 22'VERTICAL SHEET NO: OSOUTH ELEVATION ------ CEDAR SHINGLE SIDING PER SIDING,AVAILABLE FROM PIONEER MILLWORKS, A15 2 OWNER'S SAMPLE(BLUE OR SIM.); FARMINGTON, NY(585)924-9970;USE SAME SCALE: 1/8" = T-O" REPLACE SHINGLES AS NECESSARY MATERIAL FOR ALL EXTERIOR TRIM AT ADDITION SHEET 13 OF 22 [ � �\ REMOVE EXISTING FLUE AND SKYLITE; REPAIR HODGES FRAMING,SCREW&GLUE SHEATHING,APPLY RESIDENCE PROTECT EXISTING ICE&WATER SHIELD(PROVIDE\ OVERLAPS AT ALL INTERFACES w POSITIVE EXISTING \ 41.0 SOUND ROAD ASPHALT SHINGLE ROOF �\ UNDERLAYMENT),INSTALL ASPHALT SHINGLES IN GREENPORT,NY 11944 SKY PLANE �\ THIS AREA TO MATCH EXISTING I� SIDE YARD \` SKY PLANE SETBACK --- — \\� i \ PAINT ALL EXISTING EXTERIOR EXISTING CEILING i� I TRIM;COLOR PER OWNER NORTH — — — — — EL. +16'-63l4" —�i- - - - - - I — — — — — — — — — — — I I \\ SIDE YARD ® � SETBACK 0 i� 36"TALL�S.S.AIRCRAFT � i I �\ PROJECT CABLE RAILING WITH WOOD I ` EXISTING GARAGE 2°R52") TOP RAIL TO MATCH DECK REMOVED SECOND FCOOR MA�ERIALBELOW TAX MAPN0.100035:1.16 EL. +8'-7� "FLOOR ASS I' \ EXI ING CEILING - - - - - - -I- - - - - - - - — .____._ ._ _-.. „s.. `I .` I \ # ISSUE/REVISION DATE EL. W-10„ - - - - - - - - -j - - - - - - - - I I 1 I ACCOYA'TOASTED'SI-IOU SUGI BAN j I STRIP AND REPAINT EXISTING .Go REVISED FILING SET-ADDITION 10.28.2024 22'VERTICAL SIDING,AVAILABLE ^ I CEDAR SHINGLE SIDING PER j FROM PIONEEk MILLWORKS, " OWNER'S SAMPLE(BLUE OR I FARMINGTON, NYI(585)924-9970; _ I SIM.);REPLACE SHINGLES AS FIRST FLOOR USE SAME MATERIAL FOR ALL I µ:: I NECESSARY EXTERIOR TRIl AT ADDITION __ — ___ — _— I DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE I DECK STAIRS USE ACCOYA'TOASTED'SHOU SUGI BAN NOTE:THIS IS AN 11"X 17"SHEET OEAST ELEVATION FOR ALL EXTERIOR TRIM AT ADDITION DRAWINGS MAYBE PRINTED NOT TO SCALE � 'CERO'SLIDING GLASS SCALE: 1/8" = T-O" DOORS BY NANAWALL LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@iachapellearchitecture.com NEW ASPHALT SHINGLE ROOF, STRIP AND REPAINT EXISTING RED AR COLOR TO MATCH EXISTING; CEDAR SHINGLE SIDING PER PAINT ALL EXISTING g�� CHA„ y�l GAF UHD OR SIM, OWNER'S SAMPLE(BLUE OR SIM.); EXTERIOR TRIM;COLOR REPLACE SHINGLES AS NECESSARY PER OWNER �c� ��► — EXISTING CEILING --- - - - - - - - - - - - - - - - - - - - - - - - - EL. +16'-6314" — — 9�FpF NEB SECOND FLOOR EL. +8'-7" 9"FLOOR ASST ALIGN — — — — — — — — - - - - - - - - - - - - - - EXISTING CEILING „ - - - - - - - - - - - - "EL. +T-10 USE ACC 'TOASTED" "� ,PME� Rm�[m"RRE,l llFlM aE��[i^ ax,b ^4Wi0n coMv[m"xoiige"^N[RBT SHOU SUG I BAN FOR ALL EXTERIOR TRI14 AT ADDITION EAST& NORTH Grp FIRST FLOOR ELEVATIONS - - - - - - - - - - - - - - - - - EL. +O,-0„ INSECT SCREEN ACCOYA'TOASTED'SHOU SUGI BAN 221'VERTICAL STRIP AND REPAINT EXISTING CEDAR SHEET NO: NORTH ELEVATION ACCOYA'TOASTED' SIDING,AVAILABLE FROM PIONEER MILLWORKS, SHINGLE SIDING PER OWNER'S O SCALE: 1/8" = 1 -O" SHOU SUGI BAN FARMINGTON, NY(585)924-9970; USE SAME . SAMPLE(BLUE OR SIM.);REPLACE A16 INFILL PANEL,TYP. MATERIAL FOR ALL EXTERIOR TRIM AT ADDITION SHINGLES AS NECESSARY SHEET 14 OF 22 USE'VALLEYVENT'CURROGATED NAILERS HODG ES BY DCI PRODUCTS AT ALL VALLEYS, ES'®E (�E EAVES,DORMERS,ETC.ACCOMPANIED BY FURRING ELSEWEHERE,IN ORDER TO 410 SOUND ROAD ALLOW LATERAL AIR MOVEMENT TO GREENPORT,NY 11944 AREAS OF THE ROOF NOT SERVICED BY THE 2'AIR GAP GRACE ICE&WATER AT ENTIRETY OF PITCHED ROOF;SEE DETAILS ICE 2x10 RAFTERS,72'CLOSED-CELL TRUEI O SPRAY FOAM(R52),2 AIR GAP; SEE DETAILS 60 PROJECT O NORTH (27.52°) TAPERED P.T.2x SLEEPERS ASSEMBLED I TAX MAP NO.100035:1-16 WITH HARDWOOD ROOF DECKING IN PALETTES;WEIGHT OF ASSEMBLY ## ISSUE/REVISION DATE MEETS CODE UPLIFT REQUIREMENTS AND ALLOWS FOR REMOVAL FOR .00 REVISED FILING SET-ADDITION 10.28.2024 MAINTENANCE AND CLEANING EPDM OR KEMPER PUR-TYP 'US ROO NT' LIQUID APPLIED ROOFING DCI PRO CTS 2'FIBER ROOF F VENT 24"' 0VE I DRAWN BY.J.LACHAPELLE UNDERLAYMENT PATIO OF I CHECKED BY:I.LACHAPELLE TAPER OUTRIGGER CONT.(2 2.0E NOTE:THIS IS AN 11"x 17"SHEET FRAMING ATEAVE MICROLLAM11" ' LVL I DRAWINGS MAY BE PRINTED NOT TO SCALE 01L.SECOND FLOOR BY WEYERHAEUS AT EL. +g'_7" EVES LaChapelle Architecture PLLC 9"FLOOR ASS'Y _ _ _ _ P.O.Box 1251 4 EXISTING CEILING 2x6 FRAMING CONT. OE MICROLLAM EL. +7'_�p" — — — — — 2x4 FRAMING I 13i 9�"LV BY Mattituck,NY 11952 - a a (646)251-5058 jake@lachapellearchitecture.com 6"STEP FROM WE ER USER AT EAVES; BEDROOM TO DECK �� ►W- DRESS PE R DETAIL WHERE I w 4"PLYWOOD OVERLAID a EXPOSED; USE TRIPLE KING 2x8 RAFTERS,72"CLOSED-CELL w/""GWB ON NORTH go- I STUDS PER R602.7.5 RED q SPRAY FOAM(R52);SEE DETAILS o a WALL OF KITCHEN G\��E %-A RCy� O I.L. 2x6 STUD FRAMING,TYP. AAF 2x6 STUD FRAMING,TYP.2" ;; ~ KITCHEN O LIB Y LL a 2 CLOSE -CELL SPRAY �� n CLOSED-CELL SPRAY FOAM+32' a FOAM+32 lClj I-_ MINERAL UNFACED BATT UNFACED MINERAL WOOL O MINERAL OOL INSULATION INSULATION(R14+R15);SEE DETAILS OVERLAP JOISTS (R14+R15);SEE DETAILS OIL FIRST FLOOR J 24 AT BEAM — — SELF-ADHERING WEATHER ��� 033m EL. +0'-0" — — — — RESISTIVE BARRIER;SEE OF N ENN SELF-ADHERING WEATHER N DETAILS RESISTIVE BARRIER;SEE DETAILS CRAWLSPACE v "b OMWuaO PAN WsiR°e[M DP9[R[W[AN 4c",PEu[ ARCNII[CNR[PLLcgFDARDLF*S��KN[ixFRTM[ M[CiiORW�IIiC rtb PPFPMEDIS RCNR[RYR[vL G"i�pDuw�ND MAYHOf°0[YS[O BYOtT"W PtPfl[S PDR°T"N PRa[ci5. 2"XPS INSULATION AT CRAWL ..'.: ! ! [ADRPDRwRPL[TwNaP,RbPRa[ET,. L----. ®cOPVWaXisMat4cxaP[u[uxMi[rntP[PLLc SPACE FOUNDATION(R10);SEE DETAILS L --------------- SECTION SHEET NO: OSECTION SCALE: /4" _ T_C A17 SHEET 15 OF 22 HODGES RECLINER BY OWNER LOCATION OP DESK BY OWNER RESIDENCE 11v F ----�_--_-.-�------�--- — 410 SOUND ROAD I I GREENPORT,NY 11944 I 10"DEEP HALF SCREENED PORCH j PTD.6"WOOD HEIGHT SHEI]VES _ CATHEDRAL CEILING _ _ PLANK FLOOR TRUE NORTH O 392"' 12"PORCELAIN 1 TILE FLOOR _ '4' 4C 7L —— x — 4 A2 2\ ——————— --------- \ NRTH PROJECT 0 siCATHEDRA�CEILING' / \ 3 T-10" EI LI NG ` j TAX MAP NO.1000-35:1.16 — 3 20 _ 4' 4'-O" LOVESEAT BY _ 14"DEEP HALF j # ISSUE REVISION DATE JUJLINEN OWNER HEIGHT SHELVE I I I .00 REVISED FILING SET-ADDITION 10.28.2024 I I TT 60" mg II I I OPART PLAN - BATH 1 O PART PLAN - LIBRARY & SCREENED PORCH DRAWN BY:J.LACHAPELLE SCALE: 1/4" = T-O" SCALE: 1/4" = T-0" CHECKED BY:J.LACHAPELLE LOCATION OF CREDENZA BY OWNER NOTE:THIS IS AN 11"x 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE - u SOAKING TUB CENTERED IN LaChapelle Architecture PLLC ROOM 3 5-0 14-1 P.O.Box 1251 19'4" SEE GWB SURROUND Mattituck,NY 11952 DETAIL FOR DOOR (646)251-5058 jake@lachapellearchitecture.com Q O E p I I -----r---� c'�Ist PROVIDE WOOD RED ARC PTD.6"WOOD i i ___ COUNTERTOPS �' PLANK FLOOR ;""--"""-------""" THROUGHOUT KITCHEN; ��5 ��,_NCHAp�` 10'-0" SELECTION BY OWNER O� 0 5 TWO-DRAWER DISHWASHER; I ; -51v SIN `V I FISHER&PAYKEL ——— --------------- KITCHEN o----- I � 0.4 s 8 A22 6 I DD24DAX9N OR SIM. ;; t LOCATION OF 3 7 I BENCH BY OWNER 36 VENT HOOD;ZEPHYR L___ t---- ---------- - LAYERS WALL DLA-M90ASSX 6 A21 4 —_ T�O F NE�y (106 SF) III 30"FOUR-BURNER RANGE; ___ ___ 1 5 0 SEE DET.2/A21 FOR 7�� MAKE/MODEL TBD ISLAND ELEVATIONS �N DRAWER MICROWAVE; 12"PORCELAIN — L GN M SHARP SMD2479JS ORMS � .1 / TILE FLOOR SIM. _-_-___-_.,.--- ----- --------------- --------- FURR OUT GWB I I I PART PLANS 3 SURFACE AT EXISTING I I I LINEN CLOSET WALL FOR ALIGNMENT 30" WITH NEW FULL HEIGHT PANTRY I I I i r CABINET SHEET NO: O LOCAL E W(NDOW �� �� PANEL READY REFRIGERATOR PART PLAN - BATH 2 O PART PLAN - KITCHEN SCALE: 1/4" 1'-0" SCALE: 1/4" 1'-0" SILL AT402";SEEGWB 36"FARMHOUSE SINK; (MAKE/MODELTBD) A18 = = SURROUND DETAIL ELKAY ELXUFP362010JB0 INTEGRATED INTO CABINETS SHEET 16 OF 22 HODGES SIDE OF RIDGE BEAM RESIDENCE a I 410 SOUND ROAD GREENPORT,NY 11944 PAINTED BEADBOARD OVER PRIMED GWB;PAINT RIDGE BEAM a _ TO MATCH PLANK I `; v O e, WINDOW WALL BY ° TRUE MARVIN,SEE A20 FOR a NORTH ADDITIONAL DATA PROVIDE DETAILED I -cM PROJECT kk SHOP DRAWINGS FOR M 20RTH 52') OWNER/ARCHITECT � a REVIEW W&COMMENT- . . . . o c. 21TERATIONS \ I \\ a # ISSUE/REVISION DATE PAINTED 4' I \ _� .00 REVISED FILING SET-ADDITION 10.28.2024 r BOOKSHELVES,SOLID \ . . . . . . . . . . . . WOOD EDGING; ADJUSTABLE SHELVES a T T I T T ON 5mm S.S.SHELF PINS a, Cl? I / \ N I! DRAWN BY:J.LACHAPELLE T CHECKED BY:J.LACHAPELLE V' NOTE:THIS IS AN 11"x 17"SHEET d, 11-ro" DRAWINGS MAY BE PRINTED NOT TO SCALE OLIBRARY - NORTH O LIBRARY - EAST SCALE: 1/4" — T-0" SCALE: 1/4" — T-0" LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 j (646)251-5058 jake@lachapellearchitecture.com PAINTED BEADBOARD �O j OVER PRIMED GWB; PAINT RIDGE BEAM TO MATCH PLANK �\S?,ED qRFb 1 F j o F I F N E`N I 'v o . Ci, Ci. .. .I � n""enuuivuc ueuwo""niaivm`Vn6`nurnere`o c�'c'ioawnicxrtavur.''"acon PAINTED 5"BOOKSHELVES SOLID WOOD EDGING, T T ro ADJUSTABLE SHELVES ON INTERIOR 5mm S.S.SHELF PINS . ELEVATIONS LIBRARY oil ZV j co CV SHEET NO: *a- O3 LIBRARY - SOUTH 15'-2" d 4'-53" 4 LIBRARY - WEST I SCALE: 1/4 — 1 0 O SCALE: 1/4 — 1 -0 A19 SHEET 17 OF 22 ACCOYA'TOASTED'SHOU H O D G ES SUGI BAN 42'VERTICAL RESIDENCE SIDING AT CEILING I 410 SOUND ROAD I GREENPORT,NY 11944 N I ® 0TRUE, NORTH _ ® $ CM I PROJECT 2OR52 e, O I _ I C? I M I I TAX MAP NO.1000-35:1-16 C I I 0 ISSUE/REVISION DATE Cn .00 REVISED FILING SET-ADDITION 10.28.2024 FE � I I I I I I I I I I I � I iv I DRAWN BY:I.LACHAPELLE CHECKED BY:J.LACHAPELLE 2'-8" 4— 2'-8" 4 � 2'-8" �' 2'-10" 2'-10" 4' 2'-8" 4 NOTE:THIS IS AN 11"x 17"SHEET (2)ACCOYA DRAWINGS MAY BE PRINTED NOT TO SCALE PORCH - NORTH 'TOASTED'SHOU PORCH - EAST I 1 CALE: 1/4" = T-0" SUGI BAN 21"KICK O SCALE: 1/4" = 1'-0" LaChapelle Architecture PLLC BOARDS TO P.O.Box 1251 PROTECT SCREEN WOOD INFILL PANEL TO Mattituck,NY 11952 ACCOYA'TOASTED' a I MATCH ADJACENT FINISHES (646)251-5058 jake@lachapellearchitecture.com SHOU SUGI BAN 2" I VERTICAL SIDING I I r BRED AR` v Ire, I ° I C WINDOW WALL BY MARVIN; PROVIDE 2'X 4"STEEL PLATE, PRIMED, BTWN q I ALL MULLED CONDITIONS-SEE MFR T DETAILS I I CY3 PROVIDE DETAILED SHOP DRAWINGS I I y r v FOR OWNER/ARCHITECT REVIEW& I I _ COMMENT-2 ITERATIONS F NE wnmici v�P�'uouroino°w`v,"� "onx°A0'nwnnePuoa O r 9FIRAI aemm."o cn.xau.urzw*nns.oxu D iwvee`"uo��e�"eruc�ue rnc"rtnuae nc.nn ozovaxa Ma"mee usm I T T I T T INTERIOR ELEVATIONS-PORCH L SHEET N0: 2'-9" - - 2'-9" - 2'-9" - 2'-9" OPORCH - SOUTH O PORCH - WEST 11 r0 A20 SCALE: 1/4" = T-0"' SCALE: 1/4" = T-0" SHEET 18 OF 22 DRAWER MICROWAVE H O DG ES RESIDENCE a. SATIN LATEX PAINT-COLOR'a'PER OWNER'S SAMPLE 410 SOUND ROAD b. SATIN LATEX PAINT-COLOR'U PER OWNER'S SAMPLE GREENPORT,NY 11944 C. SATIN LATEX PAINT-COLOR'C'PER OWNER'S SAMPLE f. d. SEMIGLOSS LATEX PAINT-COLOR'd'PER OWNER'S SAMPLE e. SEMIGLOSS LATEX PAINT-COLOR'e'PER OWNER'S SAMPLE f. POWDER COAT FINISH WOOD CABINETRY-COLOR T PER OWNER'S SAMPLE --- 414" — — 3'-4" — 2'-2" 3'-10" g. 316 POLISHED STAINLESS STEEL SHEET-20 GA. NORTH EAST TRUE O NORTH PROVIDE SAMPLES OF ALL FINISHES FOR OWNER/ARCHITECT REVIEW AND SELECTION SINGLE VERTICAL'FIN' O O KITCHEN FINISH SCHEDULE SUPPORTFOR COUNTER-STEEL PROJECT NORTH NO SCALE REINFORCING AS (27.520) NECESSARY WOOD KITCHEN CABINETS ARE AWI PREMIUM GRADE THROUGHOUT,INCLUDING 51-6" 4'-4" � � 3'-10" TAX MAP NO.1000-35:1-16 LUMBER,SHEET PRODUCTS,AND FINISH.THE HIGHEST LEVEL OF QUALITY, MATERIALS,WORKMANSHIP,AND INSTALLATION IS REQUIRED. SOUTH f WEST # ISSUE/REVISION DATE 2 KITCHEN - ISLAND ELEVATIONS O SCALE: 1/4" T-0" DG REVISED FILING SET-ADDITION 10.28.2024= HALF-GLAZED WOOD NANAWALL CERO II LIBRARY DOORS; PROVIDE HIGH-PERFORMANCE ROLLER SHADES SLIDING GLASS WALL N DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE e. e. NOTE:THIS IS AN 11"x 17"SHEET �k DRAWINGS MAY BE PRINTED NOT TO SCALE / \ T T - LaChapelle Architecture PLLC TL a. a. M P.O.Box --- \ / ——————————————— 11 T �——— ———� Mattituck,NY 11952 SEE 2/A23 FOR ISLAND I I SEE 2/ 3 FOR I _ (645)251-5058 jake@lachapellearchitecture.com I \ a IS D N T T OKITCHEN - NORTH d. d d• \� EDq�C 3 O KITCHEN - EAST C� �lACygA y, SCALE: 1/4" = T-0" 4 SCALE: 1/4" = T-0" << i —2" ill oil - 31-0.1 0 6 I Err ��F 10 OF N ESN LIVING ROOM _CP BEYOND / i ncmnnunevue uaxo"v orvmnmarn recr ronwxw rtov°°ru"ois �M \ // // / � as<nm°oenaraes.nuen.rwxs.onoaerwns Msree euoe exccvrsruewveu° � \ r0 cruav"°"i,aius�nrrvneuim°Y nuxe vue 'mcomce mom'iuwvu"°ieo�rc°rtee°piu"r crone°e° \ o 001 000 — — INTERIOR SEE 2/A23 FOR I ISLAND ELEVATIONS-KITCHEN d. 2'-8" — 4'-0" 3'10" - 2'-0" 2'-3" 2'-6" 1'-5" SHEET NO: OKITCHEN- SOUTH f. I 2-DRAWER DISHWASHER 6 KITCHEN- WEST A21 SCALE: 1/4" = T-0"' O SCALE: 1/4" = T-0" SHEET 19 OF 22 PROVIDE LO-OMNIRIDGE HODGES PVC (AZEK) TRIM NOTES MODEL LOR94FR RIDGE VENT 4' S.S.VERMIN SCREEN AT 2"AIR so 1. USE DUST COLLECTION SYSTEM FOR ANY PVC CUTTING WORK BY LOMANCO(AVAILABLE SPACE ABOVE BAFFLE RESIDENCE PERFORMED OUTSIDE THE HOUSE,IN ORDER TO ELIMINATE FROM ABC SUPPLY CO.)AND qCF � •� AZEK BEAD BOARD 410 SOUND ROAD COOT.ZINC STRIP AT RIDGE , RELEASE OF PVC CUTTINGS ON SITE.CONTAMINATED SOIL WILL BE GREENPORT,NY 11944 COMPOSITE SLATE SHINGLES REMOVED AND REPLACED AT CONTRACTOR EXPENSE.2. USE'CORTEX'HIDDEN FASTENING SYSTEM BY TIMBERTECH w/ GRACE ICE&WATER SHIELD AT PLUGS AND#8 SCREWS;SELECT SCREW LENGTH APPROPRIATE ,. BLOCKING ENTIRETY OF NEW ROOF FOR TRIM THICKNESS AND SUBSTRATE. 2X10-ROOF-RAFTERS=PE; ®' 3. ANTICIPATE THERMAL MOVEMENT IN USE OF PVC TRIM; PROVIDE FRAMING PLAN TRUE O JOINTS FOR EXPANSION AND CONTRACTION,AS WELL AS I NEW CUSTOM NORTH SUFFICIENT FASTENING TO AVOID WARPING AND OIL-CANNING IN 72"CLOSED-CELL SPRAY FOAM '4,4. COPPER GUTTERS WARM WEATHER. (R-52);ALLOW FOR 2"AIRSPACE AND LEADERS 4. USE MINIMUM(2)FASTENERS EVERY 16"FOR TRIM BOARDS UNDER ABOVE USING TRAYS THROUGHOUT PROJECT O 8 IN WIDTH AND(3)FASTENERS EVERY 16"FOR TRIM BOARDS NORTH 62 OVER 8'IN WIDTH.FASTENERS MUST PENETRATE SUBSTRATE 1 2' FURR OUT CATHEDRAL CEILING r; rax MAP No.1oo0.3b:1-is MINIMUM. GWB AS NECESSARY TO DRESS RAFTERS IN a'AZEK 5. GLUE TRIM TO SUBSTRATE WHENEVER PRACTICAL, USING LIQUID ACHIEVE FLAT SURFACE NP i "v RUN PLYWOOD SHEATHING UP AS # ISSUE/REVISION DATE NAILS OR SIMILAR ADHESIVE. HEAD& - BAFFLE;NOTCH AROUND 6. USE SCARF JOINTS AND APPLY CELLULAR PVC CEMENT TO ONE JAMB `r ADDITION SURFACE.FASTEN AT BOTH SIDES OF JOINT.USE CEMENT w/CURE PROFILE RAFTERS .00 REVISED FILING SET-ADDITION 10.28.2024 TIME LESS THAN 2 HRS. 20 oz.COPPER DRIP 7. SAND RIPPED EDGES TO CLOSE OPEN CELLS(DISCOURAGES INTERIOR TRIM PER OWNER'S SAMPLE; a a AT ADDITION:RUN SIDING TO WINDOWS ARE FACTORY-FINISHED WINDOW FOR LOW PROFILE TRIM WATER ABSORPTION AND RESULTANT ORGANIC GROWTH). ��, 8 CLEAN PVC TRIM ACCORDING TO MANUFACTURER INSTRUCTIONS COLOR INSIDE AND OUT TO i.';j DETAIL;AT EXISTING HOUSE: PRIOR TO PAINTING. PRIME AS NECESSARY. SELECTED BY OWNER � #;i DRAWN BY:J.LACHAPELLE 9. ASSUME ALL PVC ON JOB WILL BE PAINTED. USE PAINTS(WHERE CONT.SEALANT AND BACKER ROD ! PROVIDE22'PVC TRIM,SILL CHECKED BY.J.LACHAPELLE AMB EXTENSION,&APRON FOR J REQUIRED)w/LIGHT REFLECTANCE VALUE(LRV)OVER 55.USE AT PERIMETER OF WINDOW TO TRADITIONAL DETAIL NOTE:THIS IS AN II"x17"SHEET SPECIALLY-FORMULATED VINYL-SAFE PAINT w/SOLAR REFLECTIVE STOP AIR INFILTRATION DRAWINGS MAY BE PRINTED NOT TO SCALE PIGMENTS. PROVIDE WINDOW EXTENSIONS SEE A3 WINDOW SCHEDULE 10.REPAIRS CAN BE MADE w/DAP'CRACK SHOT'FOR PAINTED TRIM. AS NEEDED DAM BLOCKING AT SILL LaChapelie Architecture PLLC REPAIRS ARE NOT ALLOWED ON UNPAINTED TRIM. USE SIMILAR TRIM AT 5„ P.O.Box 1251 2x6 SPUD°FRAMING;TYP�� ALL INTERIOR DOORS r 8 - Mattituck,NY 11952 PLACE FOUNDATION SO THAT JOISTS 2 CLOSED=CELL SPRAY_FOANf�+ POSITION FLOORING ALIGNED WITH EXISTING WOOD FLOORING TO MATCH 32'BATT UNFACED MINERAL (646)251-5058 jakeC�lachapellearchitecture.com TYP.SILL WOOL INSULATION(R14+Rl5) NOTE: EXIST.SUBFLOORING MAY BE EXISTING; PROVIDE PROFILE Sri; DIFFERENT THICKNESS THAN NEW SOUND-DAMPENING AOR-APPROVED WATER RESISTIVE 32 PLYWOOD SUBFLOORING UNDERLAYMENT BARRIER(WRB);VAPOR ��R-D ARC,y a2"PLYWOOD SUBFLOOR; PERMEANCE BTWN.6.5 AND 30 REPAIR i ADDITION GLUED&SCREWED TO JOISTS PERMS SUCH AS'HYDROGAP SA'BY EXISTING PER CODE REQUIREMENTS OBDYKE OR HENRY BLUESKIN WITH WOOD FLOOR AL N — 1„Alm DRAINAGE MAT;AS ALTERNATE USE JOISTS{OR 7Z TJI-110 BY•WEYERHAEUSER- 'ZIP'SYSTEM BY HUBER WITH OR E(QUIVALENT-@16'O.C.;'FOLLOW'ALL` DRAINAGE MAT-ONLY w/ CODI�AND MFR REQUIREMENTS] ARCHITECT APPROVAL j! 7"MINERAL WOOL INSULATIONI "PLYWOOD_SHEATHING;GLUE&= 9�F OF NE`Ny i� (R-30)AT RIMBOARDSCREW_ " RIMBOARD BY WEYERHAEUSER OR �� POSITIVELY SIDING PER ELEVATIONS COMPATIBLE EQUIVALENT; FULLY BLOCK ALL LAP WRB FLOOR ASSEMBLY CANTILEVERED li POSTS(E.G.CORNER FRAMING,KING STUDS, 3„ !; 24 OVER FOUNDATION TO ETC.)FROM LOAD ABOVE TO BEARING BELOW 24'OVERHANG ACCOUNT FOR THICKNESS OF °°•"� �°yee �s � ��•� SEAL RIMBOARD TOP AND BOTTOM ! FOUNDATION INSULATION EXISTING -�� 1 x 3 PVC BLOCK NEW 2x1`0 P T:SILL`PLATE 20 oz.COPPER DRIP DETAILS •, ASSEMBLY CRAWLSPACE EQ. SILL GASKET ABOVE AND BELOW CONPROCO EXTERIOR WALL TERMITE SHIELD SYSTEM OVER FOAM INSULATION: 2'DIA.THREADED ROD ANCHOR(MIN. 7 STUCCO FINISH w/EMBEDDED S.S. SHEET NO: OTYPICAL SECTION DETAIL @ KITCHEN TRANSITION 24"EMBED)OR 2"DIA.J-BOLT;@ 32"O.C. WALL SECTION AT LIBRARY LATH REINFORCING (6 FROM CORNERS,12 FROM END OF 2"CONT.XPS INSULATION A23 SCALE: 12" = 1'-0" PLATE); PROVIDE CUT WASHER O SCALE: 11" — T-0" TYPICAL PARTITION SHEET 20 OF 22 FRAME OR BLOCK HODGES SANDED SEALANT AT CHANGES TO JOISTS MATCH CROWN AND BASE OF MATERIAL OR PLANE;COLOR MOLDING IN ADJACENT ROOMS TO MATCH GROUT CUSTOM BEAD BOARD OR OTHER RESIDENCE PORCELAIN FLOOR TILE, T PANELLING WHERE INDICATED,AND 410 SOUND ROAD BASEBOARD TILE,AND SANDED AS PER OWNER REQUEST GREENPORT,NY 11944 GROUT SELECTED BY OWNER ATHROOM IMOLD-RESISTANT WALL BOARD SADDLE WIDTH TO ALIGN WITH SUCH AS GOLD BOND XP BY NAT. DOOR FRAME GYPSUM COMPANY .42"HARDIBACKER BOARD GLUED SOUND-ISOLATING MINERAL WOOL O AND SCREWED TO SUBFLOOR INSULATION("SAFE'n'SOUND"BY TT®ROCKWOOL OR EQUAL)WHERE NORTH , ALUM.TRANSITION BY SCHLUTER � `yINDICATED IL � REPAIR AND REPLACE EXISTING WOOD 2x4 FRAMING;USE SELECT O PROJECT WOOD SUBFLOOR WHERE NEC.; STRUCTURAL TO MINIMIZE NORTH RE-SCREW THROUGHOUT OUT-OF-PLANE ISSUES IN NEW (27.52') OTYPICAL PARTITION 3 DETAIL WALL TAX MAP NO.1000-35:1.16 SCALE: 3" = T-0" # ISSUE/REVISION DATE 6"X z'GALV.DOWELS @ 16"O.C. 2"CONT.XPS INSULATION .00 REVISED FILING SET-ADDITION 10.28.2024 WHERE COLUMNS AND NEW ADHERED TO OUTER FACE OF CONTINUED ON A19 FOUNDATION WALLS MEET EXISTING CONTINUED ON A19 CONCRETE(R-10) BACKFILL II CONCRETE COLUMN AT .Tl °• i \�\ \\\\\\\j\\\jj AOR-APPROVED SELF-ADHERING LOCATIONS INDICATED ON A10 :i FOUNDATION WATERPROOFING DRAWN BY:J.LACHAPELLE JJI IIbI III o MEMBRANE SUCH AS POLYWALL CHECKED BY:1.LACHAPELLE se. .. lll� a.• - �� NEW NEW :�f l DIMPLE SHEET; USE ADHESIVE TO NOTE:THIS IS AN li"X 1T"SHEET FFIX-NO FASTENERS THROUGH DRAWINGS MAY BE PRINTED NOT TO SCALE Il l° a CRAWL 15 MIL CLASS 1 VAPOR RETARDER CRAWL If ° N MBRANE IIj SUCH AS'STEGOCRAWL';TURN 4: 11� . •a `�_ S&EDULE 30 PERFORATED PVC LaChapelle Architecture PLLC UP 8"AT PERIMETER AND FASTEN 4J PIPS w/HOLES FACING DOWN,MIN TO ALLS WITH TERMINATION BAR tj ul I a •° ° I.l P.O.Box 1251 SLO 'E 4"IN 100 FT TO DRYWELL; Mattituck,NY 11952 PLACIE PIPE BELOW BOTTOM OF (646)251-5058 jake@lachapellearchitecture.com 4"THICK CRUSHED CRAWL P II S ACE FLOOR IN CRUSHED EXIST. LL--_ v STONE(NO FINES) ° STONE(NO FINES)WRAPPED IN BASEMEN •:� m.� — ° ° ® GEO-�EXTILE FILTER FABRIC ° - UNDISTURBED SOIL r ,ERE�q•T�C ° ° j ° ° •• d d J �,ACH�AF PROVIDE BENTONITE WATERSTOP IN J T <e- CONTIN000S STRIP BETWEEN r A i EXISTING AND NEW CONCRETE 8"CIP REINFORCED CONCRETE FOUNDATION WALLS;'BENTOSWELL' FOUNDATION WALL AT PERIMETER t r BY OCM OR SIM. OF NEW CRAWLSPACE a 24"x 12"CONTINUOUS CIP J CONCRETE FOOTING AT N E PERIMETER w/(3)#5 BAR CONTINUOUS; MIN.3"COVER FOR BAR •"�.nwepwW°..Mawo� � "�o,�°."� DETAILS PROVIDE UNDERPINNING AS NEEDED AT EXISTING FOOTING&FOUNDATION SHEET NO: TYPICAL SECTION DETAIL @ PIER JUNCTION w/ HOUSE O TYPICAL SECTION DETAIL @ FOUNDATION A24 SCALE: 12" = 1'-0" SCALE: 12" = T-0" SHEET 210E 22 DECK NOTES LEDGER FLASHING HODGES PROVIDE 2x8 JOISTS&LEDGER RESIDENCE 1. REFER TO THE LATEST VERSION OF THE AMERICAN WOOD POLYETHYLENE(OR (2)2x10 EDGE BEAM COUNCIL'S'PRESCRIPTIVE RESIDENTIAL WOOD DECK OTHER I 410SOUND ROAD CONSTRUCTION GUIDE'. WEATHER-RESISTANT) GREENPORT,NY 11944 2. ALL FRAMING LUMBER TO BE NO. 1 GRADE OR BETTER, LEDGER SPACERS FOR GROUND-CONTACT PRESSURE TREATED.[GLUE-LAMINATED DRAINAGE TIMBER BEAMS ARE ALSO FEASIBLE;IF DESIREABLE PLEASE SIMPSON LUS28 JOIST I CONSULT WITH ARCHITECT FOR SIZING.THEY MUST BE TREATED HANGER,TYP. WITH AN OIL-OR WATER-BORNE PRESERVATIVE IN ACCORDANCE 7777�� CD ——I——— O WITH AWPA UI. — w NORTH 3. FLASH TOPS OF FRAMING LUMBER(BEAMS,JOISTS,STRINGERS) WITH PEEL-N-STICK BITUMINOUS PRODUCT FOR DURABILITY. =1:' 4. ALL FASTENERS,ANCHORS,WASHERS, ETC.TO BE HOT-DIPPED I PROJECT O NORTH TYPICAL SECTION NO GALVANIZED OR STAINLESS STEEL, EXCEPT THAT FLASHING I ( RTH) FASTENERS MAY ALSO BE SILICONE BRONZE OR COPPER. 5. ALL CONNECTORS(JOIST HANGERS,STRAPPING,ETC.)SHALL BE TAX MAP NO.1000-35:1-16 HOT-DIPPED GALVANIZED OR STAINLESS STEEL. 6x6 COLUMNS I 6. BEAM SPLICES MUST OCCUR AT POSTS.STAGGER SPLICES WHEN # ISSUE/REVISION DATE COMPOSED OF TWO 2x1 OS, , o 7. USE 5/4"x 6"BLACK LOCUST/ACCOYA DECKING,TOENAIL .00 REVISED FILING SET-ADDITION 10.28.2024 ° FASTENED USING THE'CAMO'SYSTEM. DO NOT OIL DECKING. SIMPSON COLUMNId ° OR BASE W/ 8. AZAK DECKING BY TIMBER TECH TO BE FACE FASTENED OR STANDOFF TOENAIL FASTENED USING THE'CAMO'SYSTEM.DECKING COLOR f �. I DRAWN BY.J.LACHAPELLE TO BE SELECTED BY OWNER. I I _ • °i •a a I • M CHECKED BY.J.LACHAPELLE a I ° • I NOTE:THIS IS AN 11"x 17"SHEET RAILING NOTE: DRAWINGS MAY BE PRINTED NOT TO SCALE PROVIDE 36"RAILING AT i• ° i ° i . ALL LOCATIONS WHERE DROP IS OVER 30" LaChapelle Architecture PLLC e® ` ° r. ..� d P.O.Box 1251 /'/ '♦ ° d Mattituck,NY 11952 10 (646)251-5058 jake@lachapellearchitecture.com BRING VAPOR BARRIER AND P.T.WOOD BLOCKING AT FLASHING DOWN BEHIND PVC PERIMETER OF NEW WINDOW TRIM,20 OZ.COPPER DRIP WINDOW;WRAP ENTIRELY ROUND OR SQUARE AT WINDOW HEAD WITH PEEL-N-STICK 1 FLARED FOOTING BOTTOM �REO ARC,y CAST-IN-PLACE OR PRECAST BITUMINOUS FLASHING,LAP �5 ��,CHA„I CORNERS I I SEE A9 FOR FOOTING CONCRETE WINDOW WELL;SEAL TO EXISTING CONCRETE PROVIDE PRIMED AND REINFORCING AND DATA .., , FOUNDATION WALL PER MFR PAINTED WOOD SKIRT, A INSTRUCTION,FASTEN TO EXTENSION,AND INTERIOR T 10 EXISTING WALL USING HILTI TRIM AT NEW WINDOW AND Sr KH-EZ SS316 SCREW ANCHORS v ALL PER MFRINSTRUCTION 3'-0"MIN. TYPICAL ENTIRE E BASEMENT NG WINDOWS, ` ♦ �iNCF'QRISER) / -9l�O°�3O0 PVC . F NE EXTERIOR o w INTERIOR /' CRUSHED STONE AROUND ALL m _J 0 SIDES OF WELL; FINAL GRADE v — daxx SHOULD BE ADJUSTED TO LEAVE SLOPE SAW CUT EXISTING DECK STAIR DETAIL `"` rt d vrcvaxm d xaxcn,a"cwnro.oxocrnwxs w,r xeixsue acevt xr ucxanus axcxirccr°uac rug nm muwwo ear xm x m m m mxca rarnu cow mxm vamcm> ronsnroerxdvxmemsrmxwramm,oxraxmevumnorcxnvnaem sr 4"-6"OF CASTING ABOVE �— m EXISTING FOUNDATION TO FINISHED GRADE,SLOPING ACCEPT NEW WINDOW AWAY ON ALL SIDES m SEE WINDOW SCHEDULE DETAILS FOR ESCAPE WINDOW CRUSHED STONE UNDER WELL DOWN TO NEW FOUNDATION BASEMENT FLOOR PERIMETER DRAIN SHEET NO: T EMERGENCY ESCAPE & RESCUE OPENING TYPICAL DECK DETAILS A25 SCALE: 1/4" = T-0` SCALE: 12" = T-0" SHEET 22 OF 22