Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52637-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52637 Date: 01/28/2026 Permission is hereby granted to: John Heim 612 Barclay Blvd Princeton, NJ 08540 To: Install a generator accessory to a single-family dwelling as applied for. Premises Located at: 1495 Arrowhead Ln, Peconic, NY 11958 5CTM#98.-3-10 Pursuant to application dated 12/05/2025 and approved by the Building Inspector. To expire on 01/28/2028. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessary $100.00 Total 225.00 Building Inspector W my„ TOWN OF SOUTHOLD BUILDING DEPARTMENT VL(k Town Hall Annex 543 75 Main Road P. U. Box 1179 Southold,NY 11971-0959 m { Telephone(631) 765 1$02 �'ax (631) 765-9502 t - °.pouf Date Received APPLICATION FOR BUILDING PERMIT ............ r,m .f For Office Use Only PERMIT NOar7 g c e w i ' r Buildin �+ � ---------- F , Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization farm(Page )shall be completed. Date° OWNER(S)OF PROPERTY: "#Y: Name:Jack Helm SCTM#l000- Project Address:1495 Arrowhead Ln Peconic NY ttga .` Phone#:215-806-8383 Email: Mailing Address: CONTACT PERSON: N: Name:Jesse Gaffga Mailing Address:3350 Grand Ave Mattituck NY 11952 Phone#:631-375-2737 Email:jgaffga@jtechss.com DESIGN PROFESSIONAL, IONAL INFORMATION: Name: Mailing Address.- Phone#: Email-, ' CONTRACTOR INFORMATION: Name:J-.Tech Mailing Address:3350 Grand Ave Mattituck NY 11952 i Phone#:631-375-2737 Email JgaffgaQtechss.com DESCRIPTION CI IPTION F PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair D Demolition Estimated Cost of Project: 0 other 28KW Generac Generator — le 12000.00 � Will the lot be re-graded? ❑Yes 8 No Will excess fill be removed from premises? ❑Yes No 1 cone or use aistrict in wnicn premises is srtuazea: Are tnere any covenanrs ana restrictions witn respect to this property? ❑Yes RNo IF YES, PROVIDE A COPY. M Check Box After Readln . The owner con�tra'dor/design professional is responsible far all drainage and storm water Issues a provided b 1 � P g P y Chapter 236 of the Town code.APPLICATION IS HEREBY MADE to the Building Department for the issuance:of a Building Permit pursuant to the Bullding Zone Ordinance of the Town of Southold,Suffolk,County,New Vork and other applicable taws..Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with'ali applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises'�andytn buildings)for necessary Inspections.false statementsmade herein are I punishable as a Class A misdemeanor pursuant to Section 210.45 of the New" York State Penal Law. ,Jesse Gaffga Application Submitted B r*nwt name . Authorized Agent ❑owner Y p" � g Signature of Applicant: Da te: -- STATE OF NEW YORK) SS: COUNTY of } Jesse Gaffga ... ..... :,.being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, Contractor i(S)he s the (Contract r,Agent, 'rp rate Officer,etc.) of said owner or owners, and is duly authorized to arrr or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. r Sworn before me this i da of c -0 20 ary public PROPERTY OWNER AUTHORIZATION ��� ���� ��� �� ���°�� � � YO �< pw i° �CO3 (Where the applicant is not the owners � ;�� � � ji A"I I�: residing at Jack Heim 1495 Arrowhead Ln Peconic NY 11958 y a Jesse Gaffga do hereby authorize to apply on my behalf to the,Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 22 BUILDING DEPARTMENT-Electrical Inspector �" TOWN OF SOUTHOLD w Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971 0959 , e rov Telephone (631) 765-1802 4 APPLICATION FOR ELECTRICAL INSPECTION ............. ELECTRICIAN INFORMATION (All information R� uired Date: 12/5/2025 Required) Company Name: G&S Electric ;Electrician's Name: Rob Gaurriello License No.: 31568-ME Elec. email:jgaffga@jtechss.com Elec. Phone No: 631-375-2737 31 request an email copy of Certificate of Compliance Elec. Address.. 250 Budds Pond In Southold NY 11971 ------------------------ JOB SITE INFORMATION (All Information Required) Name: Jack Heim Address: 1495 Arrowhead Ln Peconic, NY 11958 Cross Street: Indian Neck Ln Peconic Phone No.: Bldg Permit#: 00% '` email: Tax Map, District: 1000 Section:98 Block: 3 Lot: 10 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly) Install 28KW Stand-by Generac Generator Square, Footage,:, Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service SizePh[:]3 Ph Size: A # Meters Old Meter# New Service Fire Reconnect Flood Reconnect[Iservice ReconnectUlunder round[]Overhead underground LateralsJ '1 H Frame Pole work done on Service YLJN Additional Information:, PAYMENT DUE WITH APPLICATION S.C.T.M. No. DISTRICT: 1000 SECTION:98 BLOCK: 3 LOT(S):I 10 #R21-0653 LOT 9 174.70' y EL 22.1 CD N 78°11'30"E o MON EL 22.0 DW WELL_} CL 20.4 fibWrOEEP hT I i^ 24.4' L`-i PIPE 6 STOCKADE I BLUESTONE GRADE ro WDDD FENCE DRAIN DRIVEWAY 4 STOOP u.c.-unLmEs MAP OF -_ 4•� 7•o INDIAN NECK PARK H No. 551 I xx �47 4.7•�� LOT 10 `J 2 57Y FRu. STONE WALIT ar�n N D 1495 O .40 LP1 0'21.4 y0' 43.7. m ` � v oB.T 7.6' 4 qlf � 1500 GAL.S.r. P' CELLARON (2)8'OxH'DEEP L.P. I ��I Ems• DRi'WEu y>©a e'OWTDEEP '4 n 21.0 N L.P.O \, c GAS 177.2Fh 2' MON. EL 21.5 CL 18.9 S 78011-300 W LOT 11 4?p CAMPFIRE LANE DRAINAGE CALCULATIONS: Ly SEPTIC LOCATION A)DWELLING WICOVERED PORCH=3277 SOFT. POINrX POINT"B' 3217 x 0.166-534cf REQUIRED (2)6'DIA x 7'DEEP DRYWELL-619c!PROVIDED S.T. 49.5' 30.5' B)DRNEWAY-1916 SOFT. LP1 45' 43.5' 1916 x 0.166=318d L� 57' 42' (1)B'D14 x 6'DEEP DRYWELL-3540 PROVIDED ZONED R-40 NON—CONFORMING LOT FRONT YARD: 40' MIN THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL SIDE YARD: 15' MIN (35' TOTAL) FINAL 01-10-23 LOCATIONS SHOWN ARE FROM FIELD OBSERVA77ONS REAR YARD: 50' MIN REVISED 04-28-21 AND OR DATA OBTAINED FROM OTHERS. AREA: 22,165.84 Sq. Feet or 0.51 ACRES REVISED 03-14-21 ELEVATION DATUM: UNAUTHORIZED ALTERATION OR ADD17ION TO THIS SURVEY IS A WOLA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY, GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITU7ION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS ANDIOR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT 774E 71ME OF SURVEY SURVEY OF:LOT 10 OF NEW CERTIFIED TO: JOHN HEIM; LORAINE HEIM; <�MAP oF:ARROWHEAD COVE M. } ADVOCATES ABSTRACT, INC.; ,�P itµ K'o`yO,P� FILED:JUNE 20, 1963 No. 3810 CO x SITUATED AT:PECONIC r ir O TOWN OF:SOUTHOLD P� KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK yS 05 HH Q, Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 FILE #220-87 SCALE:1"=30' DATE:AUG. 20, 2020 PHONE(631)298-160B FAX (831) 298-1588 N.Y.S. LISC. NO. 050882 melntnlntng the record.of Robert J.Renneeey k Kenneth U.1loychuk P�f GENERAC® . GENERAL AIR-COOLED STANDBY - 22,,28 kW GENERATOR Residential/Commercial Standby Generator INCLUDES: STANDBY POWER RATING G007260-0;G007325-0(Aluminum-Metro Gray)-22kW 60 Hz • Cellular connectivity standard,with Wi-Fi— and Bluetooth'" capabilities G007261-0;G007326-0(Aluminum-Metro Gray)-24kW 60 Hz G007327-0;G007328-0(Aluminum-Metro Gray)-26kW 60 Hz • Electronic fuel and ignition control(EFIC) --------C007282-0;G007329-0(Aluminum-Metro Gray)-28kW 60 Hz-�� • Hydraulic lifters • Smart Exercise Technology { • True Power'" Electrical Technology • Power Zone'" 200 Controller • Oil level sensor ; • 200 Amp service rated transfer switch in bundled models , • Electronic governor t GENe r • System status&maintenance interval LED indicators AC •' : _ • Sound attenuated enclosure ;n • Natural gas or LP gas operation • ecobee by Generac Smart Thermostat included in select bundles QN. • 5 Year limited warranty,generator and transfer switch r QUI n • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.* NOTE: CETL certification only applies to unbundled generator *Must be located awayfrom doors, windows,and fresh air intakes and in units. Units bundled with the transfer switch are ETL certified in the USA only. accordance with local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O MOBILE LINK@ CONNECTIVITY: Standard with the Generac Air-Cooled Generac's success in providing the most reliable generators possible. Standby Generator home standby generators,Mobile Link Cellular allows users Generac's G-Force engine lineup offers added peace of mind and reliability for to monitor the status of their generator from anywhere using a smartphone, when it's needed the most.The G-Force series engines are purpose built and tablet,or PC.Easily access real-time operating status,maintenance alerts,and designed to handle the rigors of extended run times in high temperatures and generator readiness. Users can also connect their account to an authorized extreme operating conditions. service dealer for proactive support and streamlined service.With Mobile Link, users can see their generator is ready before the next power outage. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality O SOLID-STATE VOLTAGE REGULATION: This state-of-the-art power power. This allows confident operation of sensitive electronic equipment and maximizing regulation system is standard on all Generac models. It provides micro-chip based appliances,such as variable speed HVAC systems. optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge O TEST CRITERIA: loads to the engine.Digital voltage regulation at±1%. ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer ✓ SYSTEM TORSIONALTESTED ✓ MOTOR STARTING ABILITY network provides parts and service know-how for the entire unit, from the O ecobee by Generac SMART THERMOSTAT:This new energy manager for the engine to the smallest electronic component. home offers a seamless integration into the Generac ecosystem,managing the O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous home's HVAC systems(s)and protecting the generator from potential overloads with GENERAC POWER SYSTEMS. One reason for this confidence is that the with precision. Leveraging Mobile Link, users may also view the status of the GENERAC product line is offered with its own transfer systems and controls for generator and the LP tank level(if applicable). total system compatibility. w GENERAC @@GENERAaPROMIS E Mobile Link- •�remaaa�me uu�a danesse�d ram r,am i i I r , GENERAL® Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosure provides quiet operation and weather protection,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed muffler Quiet muffler is mounted inside the unit. • Small,compact,attractive Makes for an easy,aesthetically pleasing installation,as close as 18 in(457 mm)away from a structure. Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. • Main line circuit breaker Protects generator from overload. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Generator status Monitor the generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. • Configurable exercise and duration Select Low Speed Exercise,Smart Exercise,or Transfer on Exercise options.Adjust generator to exercise for 5-20 minutes(5 minute default). • Installation and service application Generator installers and service technicians must use the Field Pro mobile application when installing or servicing the generator. GENERACO Specifications Controls ;Mode_brittoris AUTO ' ` � _ ' _ _ _ __ ' Automatic start on utility failure P�ogrammatile exerciset`__ ' MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. -- , = OFF - Stops unit Generator wilt not automatically start on utility failure Control and charger till opete.if utility Is avarlahle SERVICE For diagnostic personnel use to prevent remote commands for safe interaction,and prevent nuisance Mobile Link notifications during diagnostic testing. rtieady to RuNMaiotsnance messages �r r V - Standard Engine Run Hours indication Standard ' r._ T .. Standard ro rs Programmable start delay between�2 1 500 seconds �� mma6le by�dealeronly) Utility nominal voltage setting Adjustable to greater than or less than 10%of 240V (90 110%,default 100%). Utlhty Voltage Loss/tietum todblity adlustatile(brownduf setting) Adfustatile against nominal volkde setting 75 80%dropout/,84 89%pickup v Y __. ._ Future Set Capable Exerciser/Exercise Set Error warning _ Standard —r-- _ — —.-e-- Ruri/Alarm/Maihteriance logs 50.events ach Engine start sequence Cyclic cranking:Engine cranks a maximum of five times at factory set intervals and durations $tarter lock out �' ' Starter canna!re engage'until b sec after engine liar stopped Smart battery charger u .. Standard ChargerfaulT/MrssingACwarnmg San dard Low Battery/Battery Problem Protection and Battery Condition Standard indication _ AutomabcUoltageRegulationwitt'OverandUnderVolhge:protechom r Standard`; ---.�.._._�___ Under-Frequency/Overload/Stepper Overcurrent protection Standard _. . ____ .r.__,___ _ Safety Fused/Fuse Problem protection Standard Automatic Low Oil Pressure/High Oil Temperature shutdown Standard 'Over crank%Overspeed(@ 72 Hz)/RPM.Sense Loss shutdown Standard 4 y High Engine Temperature shutdown Standard j lntemal Fault/Incorrect Wmngprotection Standard r Common external fault capability Standard 'Automatically upgradable firmware wa Cellular ocWi Fi Standard GENERAC® Y Available Accessories .Descnptio� k -_� A0006487350 AGM Group BTX20L Battery Every standby generator requires a battery to start the system.Generac offers the recommended battery for use Y _ _ with Air-Cooled Standby Generators. G007211-0 w EBattery Heater The battery heater wraps around the battery.Recommended for use if temperature regularly falls below 32 IF �I (0-C)• f 007102-1 Oil Heater Oil heater slips directly over the oil filter.Recommended for use If temperature regularly falls below 322F((0 IC). G007103-2 Breather Heater Breather heater is for use in extreme cold weather applications where heavy icing occurs.Recommended for use if the temperature regularly falls below 0 IF(-18°C) G005621 0 � JAuxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single largeelectrical load that Contact Kit may not be needed.Not compatible with 50 amp pre-wired switches. G009918-0-Metro Touchup Paint KitA{If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from future ? Gray corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch-up a generator r enclosure. y G007216-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance „�on an air-cooled standby generator(oil not included) G007009-0 4k LTE LP Tank Fuel Level The LTE enabled LP tank fuel level monitor provides constant monitoringof the connected LP fuel tank. Monitor Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an 'unexpected power failure.Status alerts are available through a free application to notify users when the LP tank is . min need of a refill31 wG007000-1 50 am Generac Load Managers 2 ( p) �Generac Load Manager gets(LMs)are used to optimize the performance of a standby generator.They manage large G007006-1 (100 amp) electrical loads upon startup,and shed them to aid in recovery when overloaded.In many cases,using LMs can n reduce the overall size and cost of the system. Dimensions & UPCs Model UPC 667.4 1179 G007260-0 696471103724 126.291 [46.4] G007325-0 696471104738 G007261-0 696471103731 G007326-0 696471104745 778.8 G007327-0 696471104226 [3066] 699.1 [2z49] G007328-0 696471104752 G007282-0 696471103748 I G007329-0 696471104769 639.7 1177.9 [25'191 [46.371 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems,Inc. S45 W29290 HWY.59 1 Waukesha,WI 53189 1 generac.com Part No.A0005151077 02025 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.B 07/11/2025