Loading...
HomeMy WebLinkAbout52319-Z o�tOf SOUTyo� Town of Southold * * P.O. Box 1179 o� 53095 Main Rd Urm a � Southold, New York 11971 'CERTIFICATE OF OCCUPANCY No: 46558 Date: 10/07/2025 THIS CERTIFIES that the building AS BUILT GENERATOR Location of Property: 380 Knoll Cir East Marion, NY 11939 Sec/Block/Lot: 37.-5-11 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 08/14/2025 Pursuant to which Building Permit No. 52319 and dated: 10/06/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" generator as applied for. The certificate is issued to: Barbara Keller Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 38813 9/18/2015 PLUMBERS CERTIFICATION: f Aut oriz Si nature ��AtSol', TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE COUNV-� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52319 Date: 10/06/2025 Permission is hereby granted to: Barbara Keller 11 Joyces Way Bay Shore, NY 11706 To: legalize "as built"generator as applied for. Premises Located at: 380 Knoll Cir, East Marion, NY 11939 SCTM#37.-5-11 Pursuant to application dated 08/14/2025 and approved by the Building Inspector. To expire on 10/06/2027. Contractors: Required Inspections: Fees: As Built Generator $250.00 CO Accessory $100.00 ki otal 350.00 ------ —g Inspector -I- SUFFOLK BUREAU nf E r E C T R 1 C A LI 1 N S P L C 1' 0 R S, !, n c. 5 159 Route 25A, Building 1 Suite B Miller Place, NY 11764 Telephone:631 495 8136 • Fax:631 980 6455 • E-Mail:SBEIGS@gmail.com t CERTIFICATE OF ELECTRICAL COMPLIANCE f Applicant: Oneill Outdoor Power Certificate No.: 38813 Rough In Inspection Date: Final Inspection Date: Sep 15,2015 Application No.: 38813 Building Permit No.: I t.. + County Tax Map No.: This Certificate of Electrical.Compliance is limited to the inspection and compliance of electrical equipment and/or work described i below, installed by the applicant named above, located at the premise of and not after the final inspection date above: ! Owner: Robert Keller , Site Location: 380 Knoll Circle,East Marlon,NY 11939 °J i !, Owner's Address(if different): f jj ©Residential ❑Indoor ❑Basement ❑Service ❑Shed "!1 ❑Commercial ❑Outdoor ❑First Floor ❑Pool ❑Hottub I i M �. ❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage s t, ! ❑Addition Survey Other:lGenerator , INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture HID Fixtures IJ Three Phase ® Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond L—� Single Recpt 0 Recessed Fixture CO Detect Sub Panel 24ckt AC Blower 0 Range Recpt Flourescent Smoke CO Combo Transformer Appliances Dryer Recpt Emergency 0 Time Clock [t,) Disconnect 0 Switches Twist Lock Exit Fixtures 0 Pumps GFCI Breaker Heat Pump Electric Heat 0 Pool Luminaire Exhaust Fan ( 1 !d Other Equipment:20kw GE Generator,200A Service Rated Automatic Transfer Switch E ! The electrical work and/or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements and this office. l Applicant: Oneill Outdoor Power License No.: L l I + Inspected By: Wayne Kubacki Date Of Certificate: Sep 18,2015 � p Signature: --- ! 12 x. TOWN OF SOUTHOLD—BUILDING DEPARTMENT yz. Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 oy�o aol Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT Q E C E 0 V L For Office Use Only ! y AUG 1 4 2025PERMITNO. 51,0q Building Inspector: Applications and forms must be filled out in their entirety.Incomplete Building Department applications will not be accepted. Where the Applicant is not the owner,an Town of Southold Owner's Authorization form(Page 2)shall be completed. Date:8/14/25 OWNER(S)OF PROPERTY: Name:Robert Keller SCTM#1000- Project Address:380 Knoll Circle East Marion NY 11939 Phone#:516-639-9811 Email:rkeller@nickersoncorp.com Mailing Address:11 Joyces Way Bay Shore NY 11706 CONTACT PERSON: Name: f4l _._ S _ PVC Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Mailing Address: Phone#: & Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition I Estimated Cost of Project: DOtherGenerator /7e Pc-4 - �l�,w� �iQ�S m1 l4 // $ /c- g)0 Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to'the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section WAS of the New York State Penal Law, Application Submitted By(print name):Robert Keller - 13Authorized Agent @Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Robert Keller being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the OL)ac,IZ. (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Lf th day of U 20� r1lu 0� 2�� Vlary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION NO.01 DW63069M Where the applicant is not the owner QUALIFIED IN SUFFOLK COUNTY ( pp ) CDM S3fON EKPIRE'S jUNE 30,PQ�f p I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 10.6 x % , ' I a o , CALCULATIONS FOR AVERAGE GRADE 3P 19 = \ ;> pa TO DETERMINE MAX.BUILDING HEIGHT 2N'_N a� ELEVATION TAKEN % WALL LENGTH = Ira HBSpP.I irc 11.56 1. 611.055 PR SE +`e—1 — O� 9.75' 18.4 164.7)5 Architect II I 0 I GRAVEL DRI B.P tss 12265 P.C. 1 I I Z \ _ �4 28.4' 105 2882 1. ?O EA4TAWNSTREEf N 4 \ l _ X 117 10.a 1185 &AYSHORE.N YOWC1 M 12.T B.a 101.6 TE1:891R66.TSa� �158&159s \ 12.1 Ba 1°1A fbF.t16M®266612 HmpelM I 1 \ X 148% -1615 11A0'=AVERAGE GRADE 1e ' I MAXIMUM ALLOWABLE BUILDING HEIGHT BY CODE 35A&OVE GRADE-MA%.BUILDING HEIGHT=4800' w\ 1 1 PROPOSED HEIGHT OF BUILDING=3-1 1-ABOVE 11.a ELEVATION PROPOSEO HEIGHT43.97 TO RIDGE a � KELLER RESIDENCE \ 1 ,P 7 FIRST&SECOND FLOORADDRION °°. nmN N10°28'00"W of ory 1 %.,,"fib E-IM2-KNOOdNe Eml Merin,NY 16.96' D � S=PLAN • J �} EXISTw ELEV.CALCULATIONS N37°37'45"W 0.1 1IzsEroRY HOUSEEO° .. 7.7 FRA 17.71' .s FF.EL.14.4' / ,2 b MEZZ.CALCULATIONS SITE PLANK" '„� SCALE: 1\ \ AFC f " = 10 •' 1A/ '-0 sm.rtumN.wme..WWee nm"�Lon'As�"pvd N00°05'48B \`` '° ^h m�wCgN..pW..U.E..m.W 25.35' SPRING POND �� \. \ \ a JOSEDONSURVENOL ~'! JOSEPH A:INGEGNO LAND SURVEYOR *� \ DATED DECEMBER 31,1998 REVISED 03124105 et \ ot- LOT COVERAGE: N25029'58"W\ \\ EXISTING DECK 223.83 SF=1.9%LOT COVERAGEAGE �s.c.f.M.#1Doo-G7-0s-11 57.10' TOTAL EXISTING:1,543.96 SF=13.3%LOT COVERAGE CONsiRUCIION DocuMENrs PROPOSED HOUSE:2,090.9 SF=18.06%LOT COVERAGE o EXISTING DECK:223.83 SF=1.9%LOT COVERAGE 00 PROPOSED TOTAL:2,314.73 SF= 19.96%LOT COVERAGE �� TOTAL ALLOWABLE:2,314.84 SF 20.0%LOT COVERAGE a �4 KELLER RESIDENCE CS-3 I APP 0 Eo AS NOTED oA s.P.f 5v?3 NOTIFY BUILDING DEPART NTAT 631-765-1802 SAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING A PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE ELECTRICAL OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TO N CODES AS REQUIRED AND CO DITIONS OF SOAOLDT WNZBA SOUTHO OWN PLANNING BOARD SOUTHD TOWN TRUSTEES NX3. 0 SO OLD HPGG OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY Standby - • BRIGGS&STRATfON FC3R-rRF.E3-0- 010D The Smart Choice Introducing our dealer exclusive line, Available at your local Briggs & Stratton Dealer with these great`features: 00 I Parts•Labor•Travel Limited Warranty° us C U` USYM Corrosion Resistant Enclosure&Base Symphony®II Power Management System • Rust resistant aluminum and a stainless steel base • Customizable to your home's needs to protect the generator from the elements.Robust • Automatically balances the power of your home's electrical protection against damage from the elements caused load including high wattage items like air conditioning units by strong winds, high humidity and salt air and electric ovens • Powder-coated paint for years of protection against . Offers whole house power with a more affordable chips and abrasions home generator Certified to withstand hurricane-force winds up to 175 mph' Quality Clean Power Unique Airflow Technology • Ensures your electronics are safely powered • Making these models 50%quieter than most Flexible Placement portable generators 1. • The unique design pushes engine exhaust out the • Approved for installation as close as 18"to a building' front,directly away from your home Commercial-Grade Vanguard®Engine Briggs&Stratton®Full Synthetic Generator Oil • Shields the engine from low temperature sludge buildup • Powerful V-Twin OHV engine and high temperature deposits • Easy conversion between natural gas(NG)and liquid • Reduces engine wear,scuffing"and abrasion propane gas(LP) during installation Enhanced cold weather start-up protection to-20•F Generator Set Rating Liquid Propane Vapor Natural Gas Limited Warranty' Enclosure Circuit Model Type Voltage Phase' Hz Breaker Amps LPV kW LPV Amps NO kW NO Amps Parts,Labor,Travel 040547 Galvanneal 1201240 1 60 100 20 83.3 18 75 6 Year 040573 Aluminum 120/240 1 60 100 20 83.3 18 75 6 Year 040592 Aluminum 120/240 1 60 100 20 83.3 18 75 10 Year 'This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No.100-14(motors and generators). 'The installation manual contains specific instructions related to generator placement in addition to NFPA 37,including the requirement that carbon monoxide detectors be installed and maintained in your home. 'Single phase units are rated at 1.0 power factor and three phase units are rated at 0.8 power factor. 'See operator's manual or BRIGGSandSTRATTON.com for complete warranty details. 'When installed in accordance with the installation manual v 20M' Fortress"Standby Generator BRIG6SSSTRAITON Engine SipecOications 'Engine' i u o L bricati n _r --- - Engine Brand Vanguard® Oil Capacity(oz) 79 Engine Speed(RPM) 3600 Lubrication System Full Pressure Engine Fuel Liquid Propane Vapor(LPV)or Recommended Oil 5W30 Full Synthetic Natural Gas(NG) Engine Cylinder Configuration OHV Low Oil Pressure Sensor Yes Number of Cylinders 2 s Alternator Specs_. Displacement(cc) 993 Manufacturer Briggs&Stratton Compression Ratio 8.5:1 Type Self-Excited,Rotation Field Governor Type Electronic Voltage Regulator Automatic Frequency Regulation +/-1% Insulation Class F Valves OHV with Hardened Seats Controiler'Oeatures Ignition System Fixed Timing Magnetron' Hour Meter Yes Starter Motor Rating Voltage 12 Volt LED Digital Display Yes Battery Required 12 Volt,Group 26R,540 CCA Minimum Fault Code Display Yes Weekly Exerciser Yes o . I Fuel Consumption' Sound Rating At 7 Meters Full Load 1/2 Load No Load 64 dBA4 BTU/hr NG-260,000 NO-187,000 NO-99,000 LPV-337,500 LPV-207,500 LPV-100,000 ft,/hr NO-260 NO-187 NO-99 LPV-135 LPV-83 LPV-40 m'/hr NG-7.36 NG-5.30 NG-2.80 LPV-3.82 LPV-2.35 LPV-1.13 Parts ° Labor °Travel Unlike other standby generator manufacturers, 6I Limited our warranty covers parts,labor AND travel for the Warranty' full length of the warranty with no start-up costs! 'This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No.100-14(motors and generators). Fuel consumption rates are estimated based on normal operating conditions at'h load.Generator operation maybe greatly affected by elevation and the cycling operation of multiple electrical appliances-tuel flow rates mayvary depending on these factors. 'See operator's manual or BRIGGSandSTRATTON.com for complete warranty details. 'Lowest no-load measurement per ISO 3744.Sound level measurement at other locations around generator may be different depending upon installation configuration. 2 w ' * 20M' Fortress"Standby Generator BRIGGS&STRATTON Additional Information z Other Features. Certification Galvanneal Steel or Aluminum CARBCom liant Yes' Enclosure Material with Corrosion Resistant Paint P Overerank Protection Yes NFPA Approved Yes Engine Warm Up(sec) 20 or 50 Automatic Transfer cUL Listed to CSA 22.2 No.100-04 Yes Switch Controlled Engine Cool Down(min) 1 NEMA Compliant Yes 26 or 56 Automatic Transfer EPA Certified Fuel System Yes Response Time(sec) Switch Controlled ____._ _ __ �_ __ _ Monitoring Options Basic Wireless Monitor AvailableAceessories _ ✓� �� _ _..__.___ _._ InfoHub-Monitor Continuous Maintenance Kit 6035 Battery Charging Yes '-'-71 Cold Weather Kit 6404 Weight and Dimensions .. Galvanneal-601/273` rN R Basic Wireless Monitor 6176 Assembled Weight(Ibs/kg) Aluminum-440/200 InfoHub 6517 Overall Dimensions(in/mm) 49.2 x 31.7 x 30.6/1250 x 805 x 777 Remote Status Monitor 6144 Weight(Ibs/kg) Galvanneal-626/284 Packaged Wei g Aluminum-575/261 Packaged Dimensions(in/mm) 68.1 x 41 x 39.5/1730 x 1041 x 1003 49.2 in(1250 mm) —- --- 31.7 in(805 mm) 30.6 in (777 mm) i i o 0 0 48.1 in(1222 mm) 29.6 in(752 mm) 'CARB does not regulate emergency standby generators outputting less than 50 HP.Only the EPA standards apply. 'This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard 3 C22.2 No.100-14(motors and generators). L 13RIOGS&STRATrON 20M' Fortress"Standby Generator il Fuel Pipe Size Recommendation Chart(Capacity in Thousands of BTU/Hour) Natural Gas t inlet Pr ssureless than 2 PSI/Pressure Drop 1/2"Water Column I Specific Gravity 0,60 1/2"pipe capacity 3/4"pipe capacity 1"pipe capacity 1414"pipe capacity 171/2"pipe capacity 2"pipe capacity 20'Length' 118 247 466 957 1,430 2,760 40'Length2 81 170 320 657 985 1,900 60'Length2 65 137 257 528 791 1,520 8.0'Length' 56 117 220 452 677 1,300 100'Length2 50 104 195 400 600 1,160 tiquld Propane Vapor/,Inlet Pressure 11"Water Column/Pressuro Drop112"Water Column/Specific Gravity LSO,) 1/2"pipe capacity 3/4"pipe capacity 1"pipe capacity 1-1/4"pipe capacity 1-1/2"pipe capacity 2"pipe capacity 20'Lengthz 200 418 788 1,617 2,423 4,666 40'Length2 137 287 541 1,111 1,665 3,207 60'Length2 110 231 435 892 1,337 2,575 80'Length2 94 198 372 764 1,144 2,204 100'Length2 84 175 330 677 1,014 1,954 It Support every step of the way Call today • in-homei Need help?Visit BRIGGSandSTRATTON.com Complete the web form and a local dealer will contact you to answer questions on our generators,transfer switches 800-743-4115 and accessories, 'This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No.100-14(motors and generators). -_ 'Total length of piping from outlet of regulator to appliance farthest away. BRIGGS&STRATTOf+a CORPORATION _ Briggs&Stratton has a policy of continuous product improvement and reserves the right to modify POST OFFICE BOX 702 BRIGGS sSTRATTON its specifications at any time and without prior notice. MILWAUKEE,WI 53201 USA Not for Prime Power or use where standby systems are legally required,for serious Iffe safety or health hazards,or where lack of power hampers rescue of fire-fighting operations, BS1155-8/18 Copyright©201B.All rights reserved, YOU.POWERED.