Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52498-Z
KOHLER® L. AIL Models: 26 RCA(L)6-9-V i S L °-`� Multi-Fuel LPG/Natural Gas 09001 Standard Features 4KOHLER. RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT). -� o Electronic speed control responds quickly to varying demand. o KOHLER Energy Management System for remote w monitoring is included with the generator. � P I b Command PRO Engine Features t o Command PRO®OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler' Advantage eliminate the need for stub-ups through the base. • High Quality Power o Customer connection terminal block located near the Home generators provide advanced voltage and frequency controller allows easy access for field wiring. regulation along with ultra-low levels of harmonic distortion o Designed for outdoor installation only. for excellent generator power quality to protect your • Certifications valuable electronics. o Meets emission regulations for U.S. Environmental • Premium 5-yr/2000-hr Limited Warranty Included Protection Agency(EPA)with both natural gas and LPG. Kohler is known for extraordinary reliability and o cULus listed. performance. Kohler's premium limited warranty covers o Accepted by the Massachusetts Board of Registration of parts, labor, and travel for the full warranty period. Plumbers and Gas Fitters. o Meets 181 mph wind rating. • Powerful Performance Approved for stationary standby applications in locations Exclusive PowerboostTM technology provides excellent served by a reliable utility source(on-grid). starting power. § • Exercise Modes Aluminum Enclosure o Attractive aluminum enclosure allows installation as o EcoExercise, unloaded,with system diagnostics close as 18 inches from your home or small business. t (90 seconds). Reduces fuel costs and minimizes sound disruption. o Enclosure panels can be removed without tools to allow disruption. easy access for maintenance and service. o Unloaded exercise with complete system diagnostics(20 minutes). • Enclosure Options for single-phase units o Unloaded full-speed exercise(20 minutes). o Kohler®Exclusive Colors are available. Go to o Loaded full-speed exercise(20 minutes; Model RXT ATS homeenergy.kohlerenergy.com to see the latest colors. required). o Camouflage Enclosures are available for single-phase o Weekly, bi-weekly, or new monthly exercise intervals. units(optional). Go to homeenergy.kohlerenergy.com Model 26RCAL includes a model RXT automatic transfer /MossyOak to view the available patterns. switch. See last page for more details. Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. Generator Ratings Standby Ratings,60 Hz Standby Ratings,50 Hz Natural Gas LPG Line Circuit Natural Gas LPG Line Circuit kW/ kW/ Breaker kW/ kW/ Breaker Model Alt Ph Volts kVA A kVA A A Poles I Volts kVA A kVA A A Poles 26RCA/L 2F8 1 120/240 24/24 100 26/26 109 110 2 115/230 18/18 78 18/18 78 80 2 3 120/208 21/26 73 22/27 77 80 3 220/380 16/20 30 16/20 30 30 3 26RCA 2G8 3 120/240 21/26 64 22127 67 80 3 230/400 16/20 29 16/20 29 30 3 3 277/480 21/26 32 22/27 34 40 3 240/416 16/20 28 16/20 28 30 3 Note:The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 power factor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage.No overload capacity is specified at this rating.Ratings are in accordance with ISO-304611,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derate 4%per 305 m(1000 ft.)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5°C(10°F) temperature increase above 16°C(600F).Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler Co.generator dealer for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a Kohler®Power Systems professional to calculate your exact residential power system requirements. t Meets NFPA guidelines for 18 inch clearance to combustible materials.Check state and local codes for minimum distance required from a structure. G4-315 (26RCA) 10/24e Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator . Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field . Self-ventilated and dripproof construction. Leads,quantity F8 4 Windings are vacuum-impregnated with epoxy varnish for 2 28 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and-minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H . Digital voltage regulator with±1.0%no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full Voltage regulation,no-load to full-load ±10 0/o • Total harmonic distortion (THD)from no load to full load RMS . with a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V, 1 ph,2F8(4 lead) 39(60 Hz) 27(50 Hz) 240 or 480 V.3 ph,2G8(12 lead) 63(60 Hz) 50(50 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH1006 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm'(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 10.5:1 Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM 3600 3000 Oil cooler Integral Max,engine power at rated RPM, kW(HP) LPG 26.1 (36.4) 22.7(30.4) § Kohler recommends the use of Kohler Genuine oil and filters. Natural gas 24.5(33.0) 19.5(26.2) Fuel Requirements Cylinder head material Aluminum Valve material Steel/StellitO Fuel System Piston type and material Aluminum Alloy Fuel types Natural Gas or LPG Crankshaft material Heat Treated,Ductile Iron Fuel supply inlet 3/4 NPT Governor:type Electronic Fuel supply pressure,kPa(in.H2O): Frequency regulation,no load to full load Isochronous Natural gas 0.9-2.7(3.5-11) Frequency regulation,steady state ±0.5% LP 1.7-2.7(7-11) Air cleaner type Dry Fuel Composition Limits` Nat Gas LPG Engine Electrical Methane,%by volume(minimum) 90 min. — Engine Electrical System Ethane,%by volume(maximum) 4.0 max. — Propane, /o by volume 1.0 max. 85 min. Ignition system Electronic, Propene, %by volume(maximum) 0.1 max. 5.0 max. Capacitive Discharge C4 and higher,%by volume 0.3 max. 2.5 max. Starter motor rated voltage(DC) 12 Sulfur,ppm mass(maximum) 25 max. Battery(purchased separately): Lower heating value, Ground Negative MJ/m3(Btu/ft3),(minimum) 33.2(890) 84.2(2260) Volts(DC) 12 * Contact your local dealer for suitability and rating derates based Battery quantity 1 on fuel compositions outside these limits. Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 G4-315 (26RCA) 10/24e Fuel Pipe Size Operation Requirements Minimum Gas Pipe Size Recommendation,in.NPT Fuel Consumption,ma/hr.(cfh)@ 60Hz Pipe Length, Natural Gas LPG %Load Natural Gas LPG m(ft.) 290,000 Btu/hr. 322,500 Btu/hr. 100 8.2 (290) 3.6 (129) 8 (25) 1 3/4 75 6.7 (238) 3.1 (111) 15 (50) 11/4 1 50 5.1 (180) 2.4 (85) 30 (100) 11/4 1 25 3.9 (137) 1.8 (64) 46 (150) 11/4 1 Exercise 1.9 (67) 0.9 (31) 61 (200) 1 112 1 1/4 Fuel Consumption,m'/hr.(cfh)@ 50Hz Generator Set Sound Data %Load Natural Gas LPG Model 26RCA sound levels are 56 dB(A) during engine 100 6.9 (245) 2.9 (102) exercise and 67 dB(A) during full-speed generator 75 6.2 (220) 2.5 (89) diagnostics and normal operation.* 50 5.4 (190) 1.8 (65) All sound levels are measured at a distance of 23 ft. (7 m) 25 3.7 (131) 1.3 (46) from the generator set. Exercise 1.9 (67) 0.9 (31) Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/R.3) * Lowest of 8 points measured around the generator.Sound levels LPG: 93 MJ/m3(2500 Btu/ft 3) at other points around generator may vary depending on LPG conversion factors: 8.56 ft.3=1 lb. installation parameters. 0.535 m3=1 kg 36.39 ft.3=1 gal. RDC2 Controller Features • Exercise modes: o New 90-second Eco Exercise with complete system ,,,,9a z40V diagnostics(factory default setting) FTq: 60.0Hz o Lowers fuel cost 09 o Minimizes sound disruption 6®a a r !CI o In cold temperatures, limits condensation build-up ^� in the crankcase _— o Unloaded 20-minute exercise with complete system diagnostics c Unloaded 20-minute full-speed exercise The RDC2 controller provides integrated control for the o Loaded 20-minute full-speed exercise (Model RXT generator set, Kohler® Model RXT transfer switch, ATS required) programmable interface module(PIM), and load shed kit. • Weekly, bi-weekly, or new monthly exercise intervals • Membrane keypad: • Front-access mini USB connector for SiteTechTM or USB o OFF,AUTO, and RUN pushbuttons Utility connection o Select and arrow buttons for access to system • Integral Ethernet connector for Kohler Energy configuration and adjustment menus Management • LED indicators for OFF,AUTO, and RUN modes • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch • LED indicators for utility power and generator set source o Diagnostic messages: Displays diagnostic messages for availability and ATS position(Model RXT transfer switch the engine, generator, Model RXT transfer switch, required) programmable interface module(PIM), and load • LCD display: management device. o Two lines x 16 characters per line • Maintenance reminders o Backlit display with adjustable contrast for excellent • System settings: visibility in all lighting conditions o System voltage, frequency, and phase • Scrolling system status display: o Voltage adjustment o Generator set status o Measurement system, English, or metric o Voltage and frequency • ATS status(Model RXT ATS required): o o Source availability Engine temperature o ATS position(normal/utility or emergency/generator) o Oil pressure o Source voltage and frequency o Battery voltage • ATS control (Model RXT ATS required): o Engine runtime hours o Source voltage and frequency settings • Date and time displays o Engine start time delay • Smart engine cooldown senses engine temperature o Transfer time delays • Digital isochronous governor maintains steady-state o Voltage calibration speed at all loads o Fixed pickup and dropout settings • Digital voltage regulation: ±1.0% RMS no-load to full-load • Programmable Interface Module(PIM) status displays:o Input status(active/inactive) • Automatic start with programmed cranking cycle o Output status(active/inactive) • Built-in 2.5 amp battery charger • Load control menus: • Programmable exerciser can be set to start automatically o Load status on any future day and time o Test function G4-315 (26RCA) 10/24e KOHLER® Discovery Energy,LLC 200 Twin Oaks Road,Kohler,WI 53044 USA For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLEREnergy.com Generator Set Standard Features Literature • Aluminum sound enclosure(cashmere color standard) ❑ General maintenance literature kit • Battery cables ❑ Overhaul literature kit • Critical silencer ❑ Production literature kit • EPA certified fuel system Maintenance • Field-connection terminal block ❑ Maintenance kit(includes air filter, oil, oil filter, and • Fuel solenoid valve and secondary regulator spark plugs) • Line circuit breaker ❑ Premium 300 hour/2 year oil for fewer oil changes • Multi-fuel system, LPG/naturalwis, field-convertible Automatic Transfer Switches and Accessories • Oil drain extension with shutoff valve ❑ Model RDT ATS • Oil level sensor ❑ Model RXT ATS with combined interface/load • Oil pressure sensor management board ❑ Load shed kit for RXT or RDT • KOHLER Energy Management System ❑ Power relay modules (use up to 4 relay modules for • Premium 5-year/2000 hour limited standby warranty. each load management device) Covers parts, labor, and travel for the entire warranty period 26RCAL Model Package • RDC2 generator set/ATS controller ❑ 26RCAL with 200 amp service entrance-rated Model • Rodent-resistant construction RXT with combined interface/load management board • Sound-deadening,flame-retardant foam per UL 94, and corrosion-resistant NEMA 3R aluminum enclosure class HF-1 Warranty Available Options ❑ 7-Year Limited Warranty Concrete Mounting Pads ❑ 10-Year Limited Warranty ❑ Concrete mounting ad, 3 in.thick Warranties cover parts,labor,and travel for the entire g p warranty period. ❑ Concrete mounting pad, 4 in. thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120 VAC" ❑ Carburetor heater, 120 VAC t Generator Set Dimensions and Weights ❑ Cold weather kit, 120 VAC t$ o Includes oil and breather tube heaters.fuel regulator heater,and Generator Set Size,L x W x H: 147 x 6.0 x 2.3 mm 9 (47 x 26.0 x 32.3 in.) pressure sensor cover Shipping Weights: o QS model with factory-installed kit is available(excludes fuel 26RCA Generator Set: 283 kg(625 lb.) regulator heater) 26RCAL with 200 A RXT SE ATS: 304 kg(670 lb.) ❑ Emergency stop kit L — ❑ Programmable interface module(PIM) -` (provides 2 digital inputs and 6 relay outputs) i • Battery heater is recommended below-17°C(0°F). $Do not use a carburetor heater with a cold weather kit. H t Cold weather kit is recommended below 0°C(32°F). ! ._ Enclosure Options(single-phase only) I ❑ KohlerO Exclusive Colors w ---- Go to homeenergy.kohlerenergy.com to see the latest NOTE:Dimensions are provided for reference only and should not be used for planning colors. installation.contact your local dealer for more detailed Information. ❑ Mossy Oak®camouflage enclosures Go to homeenergy.kohlerenergy.com/MossyOak to see DISTRIBUTED BY: available patterns. Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. Fuel System Accessories ❑ Flexible fuel line(included on QS models) ©2024-Discovery Energy,LLC-All rights reserved. G4-315 (26RCA) 10/24e D � N D 1190 46.8 UST AIR OUTLET AIR INLET 189 .4 IGH VOLTAGE ELECTRICAL Z STUB-UP AREA C LOWVOLTAGE C O ELECTRICAL a STUB-UP AREA yZ •• • • • WW <0 v G • N X E2 a N _ m N m � • • •• 78 13.11 MAX B CONDUIT ALLOWED - / OUTSIDE UNIT X4 NPTJ 91 '6 620 24.4 259 10.2 B 817 (FEMALE)N� 4X APPRApp.), 32-2 MAX OPEN POSITION LIFTING HOLES 570 r22.41337 113.31 • • ®• •p• F. NOTE:DIMENSIONS IN 0 ARE INCH EQUIVALENTS. DO NOT SCALE. 11lIlFSS OTHERYASE SPEClFl[D: c Au°wENSIONs w MULnnELeRs THIS ASSEMBLY OR PART MUST cENmAL mLERAN�S:wA COMPLY WITH PEP-RML-001. ON COMPOSITE DWG$SFE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR REV DATE o INDICAo PART NUMBERS AFFECTED Br IATEsT BY UNSPECIFIED DIMENSIONS. ® O DRAWING REVISION THwDANwEPR°lE°TION • • - 05DEC2022 NEW DRAWING AXH A A 11JAN2023 SEE SHEET 2 AND 5 AKH B �rAL _ KOH L E R. 14FEB2023 SEE SHEET 8 5 A MAIGR o= ° MOUNTING HOLES cNARAcmasncs wmPLrwITN sCALE:0.40 sl�Ers�:B sREET:10F5 Ias sacra 931 19.31 670 r26.41 N nTLE: DRAmc AXH DATE DIMENSION PRINT,26RCA 26RCA APPROVED:sErs 05DEC2022 MG NO.,ADV-9919 6 7 6 - 5 4 THS xuvnN°w°Es cRAN°°e Aa srasE3m.PR°aeRnANDMus Nrne/e usED omevrwcoNNZinoNvmm me exco.row Au woN sac oEmN DR�ur ENnon nsE Reswveo. 1 AIR CLEANER BREATHER TUBE D HEATER D (OPTIONAL) ` ENGINESHUTOOWN OIL FILTER SWITCH OIL DIPSTICK OIL PRESSURE SWITCH COVER j,{' t" HEATER(OPTIONAL) (OPTIONAL) xqa h `o gi \ `--OIL FILL g 0 IL DRAIN VALVE EXHAUST IL HEATER AIR OUTLET (OPTIONAL) NNLESSOTNERWISE SPECIFIFD: AuowENSloNswnnwNErERs DO NOT SCALE. eFSIERA�To�naices ww THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. �ONCO—MPOSITE DWGS.SEE PART NO.FOR REVISION L WU REFERENCE CAD MODEL FOR REV DATE o INDICATES PART NUMeETas AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. DRAWING REVSION A TBiG M'GIE PRGJECfIGN P 05DEC2022 NEW DRAWING AKH OEE] KOHLER. A 11JAN2023 D- OIL PRESSURE SWITCH COVER —OR o- o (OPTIONAL)WAS OIL, ESSURE SWITCH cwTtC ®= o S 5 AKH CHARACTERISTICS CDMPLY WITH sC 0.40 s1o=Er sme B 1 sHEET:2 OF 5 B 14FEB2023 SEE SHEET 4&5 AKH Ia'se°°a TrrLE: DRAWN: AKH DATE DIMENSION PRINT,26RCA 26RCA SYSTEM 05DEC2022 DWGNo.:ADV-9919 6 7 6 5 4 HSDRAvnNGw DESIONA moETAn sKOH FRCO.PPOPFR AND NusTNm es usso ENLEPi INGON gG WNWRH KOH ERCO.NDd ALL wGHR CF GES GN OR1wVEN WANE RESDrvEn. D ( SB PORT D • 0 ONTROLLER 3 _ 0 OAD CIRCUIT BREAKER O f ti hi.It, I USTOMER CONNECTION BLOCK '�'�FUEL REGULATOR yam` rwti HEATER PAD (OPTIONAL) VZ;-_Z; mzB �f B OIL DRAIN HOSE ' (� ATTERY CABLES (INCLUDED) -' TTERY LOCATION (BATTERY NOT INCLUDED) BATTERY HEATER (OPTIONAL) A RINLET DA�iLo�ENSGoNWslwwNiTms DO NOT SCALE THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. ON COMPOSITE DINGS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR REV DATE ❑INDICATES PART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. A DRAWING REVISION THIRD�/{N-}I�D71�E PRDg.CTON 11JAN2022 NEW DRAWING AKH DEE] KOHLER. F A 11JAN2023 SEE SHEET 2 AND 5 AKH B 14FEB2023 SEE SHEET 4&5 qKH M OR o= o cwlcx®= a CHARACTERISTICS COMPLY WITH SCALE:0.40 SHEET S-B SHEET:3 OF 5 ws eaoaz TITLE: DRAWN: AKH DATE: DIMENSION PRINT,26RCA 26RCA APPRDVED:SEYESi M 05DEC2022 mrvG ra.:ADV-9919 8 7 s S 4 THSDMWINOWDESIGN IIiDDETM 51tDlnce lb.PROPERIYANO MUST NOT BE UBEO OILFPfWCONNECiION WIM FONIERIb.NOPK PIIPoDHIb OF DESIGN ORPNEMIDN AIW RESERVED. OCCUPIED STRUCTURE OCCUPIED STRUCTURE D D NOTE: QTHE RECOMMENDED DISTANCE FROM A STRUCTURE IS DEPENDENT ON STATE AND LOCAL CODES.PRODUCT HAS BEEN DEMONSTRATED IN ACCORANCE WITH NFPA 37 SECTION 4.1A BY A THIRD PARTY TEST FACILITY i i TO THE DIMENSIONS SHOWN. C ACCEPTABLE C SERVICE DOOR 'F?L 1)EXHAUST IS AIMED AWAY OR PARALLEL TO STRUCTURE. SET OUNTING AREA OUNTING AREA 2)EXHAUST IS NOT DIRECTED AT PLAY AREAS,PATIOS OR OTHER AREAS WHERE PEOPLE CONGREGATE. RVICE DOOR 3)THE NEAREST WINDOW,VENT,DOOR OR SIMILAR STRUCTURE CLEARANCE OPENING IS AT LEAST 5 FEET FROM THE EXHAUST END OF THE SET. AT EXHAUST END 4)SET HAS PROPER OFFSET FROM STRUCTURE. U i 5)WINDOWS&DOORS ON ADJACENT WALLS ARE CLOSED. v~i 6)FURNACE AND OTHER SIMILAR INTAKES ARE AT LEAST 10 FEET FROM EXHAUST END OF SET. U 7)WEED BARRIER AND 3 INCH THICK GRAVEL BASE OR CONCRETE PAD �uS 7 LOCATED TO PREVENT GRASS&WEEDS FROM GROWING TOO CLOSE v Q TO THE SET. _ OCCUPIED 8)NO PLANTS,SHRUBS OR OTHER COMBUSTIBLES ALLOWED IN B STRUCTURE � CLEARANCE AREA(MINIMUM 4 FT.FROM EXHAUST END). 6 `oD a 9)REFER TO OWNERS MANUAL FOR OTHER INSTALLATION CONSTRAINTS. 10)NO PLANTS,SHRUBS,OR OTHER COMBUSTIBLES ALLOWED WITHIN 18'MIN. 30'OF AIR INTAKE. Q 11)MUST MAINTAIN A MINIMUM OF 3 FEET CLEARANCE FROM SERVICE DOOR ENTRANCE. SERVICE DOOR 12)OVERHANGS AND AWNINGS MUST BE A MINIMUM OF 5 FEET FROM GENSET. SET OUNTING AREA UNLESS OTHEIMASE 6PECIFIED: Au DB�NNSIDNs w DO NOT SCALE. w 0 GENFRALTOIEgAlY5.6:wA THIS ASSEMBLY OR PART MUST Z w COMPLY WITH PEP-RML-001. QN ON COMPOSITE DWGS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR W� REV DATE ❑INOICATESPARTNU SERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. A J= DRAWING REVISION Tlygp nNG c pgoiEcgoN - 05DEC2022 NEW DRAWING AKH OEE] KOHLER. ,QQ A 11JAN2023 SEESHEET2AND5 AKH M OR O= o B 14FEB2023 B-2 3 FEET CLEARANCE WAS 5 FEET CRITICAL®= B CLEARANCE,SEE SHEET 5 AKH CHARACTERISTICS coWLY WITH scnLe 0.40 SHEET Sa-B SHEET:4 OF 5 wsSovn TITLE: 26RCA DRAWN AKH DATE DIMENSION PRINT,26RCA SINGLE UNIT CONFIGURATION APPROVED:s ST M^05DEC2022 D,,,,G No..ADV-9919 B 7 6 5 4 3 2 RW OgAWINOIN OE610NANo0ETA416 NOIAER LO.PROf•WTTAND NU6TNOT BE USED EItGEPT IN CONlaEC110N WRH KOI6FA W.WOIMALL WOHi50F pE9GN oR BIVENfIONpgE gE6ERJEo. OCCUPIED STRUCTURE OCCUPIED OCCUPIED STRUCTURE STRUCTURE 18'MIN. SERVICE QDOOR 1 SERVICE Z SET gE7 DOOR z 4 MOUNTING MOUNTING AREA AREA Z zw 3FT. zw 1 MOUNTTIINEGA SERVICE 'ic Q e' DOOR x SET r' SERVCE DOOR MOUAN ING RE a OUNTIN G AREA DOOR []R�ER'CE NCE a¢ a¢ C AT EXHAUST END OCCUPIED i STRUCTURE - 0z 3FT. 0z a zw zw �N Q gy SET 41 OUNTING AREA 18'MIN. z z o O SERVICE DOOR "j CLEARANCE SET SERVICE DOOR O AT EXHAUST END OUNRNG AREA LL o¢ OCCUPIED STRUCTURE w LL w Z DO0 Uz taaw Ky 7 i SET SERVICE DOOR U= d LL m OUNTING AREA .�¢ MOUNTING AREA MOUNTING AREA NOTE: SET SET APPLY NOTES ON SHEET 4 OF 5 -ENso. m�iu�onETE s DO NOT SCALE. TO SHEET 5 OF 5. GENERM.TOIERANO " THIS ASSEMBLY OR PART MUST COMPLY WITH PEP-RML-001. ON COMPOSRE OWGS,SEE PART NO.FOR REVISION LEVEL REFERENCE CAD MODEL FOR 4 Ff.CLEARANCE SERVICE SERVICE REV DATE ❑INDICATES PART NUMBERS AFFECTED BY LATEST BY UNSPECIFIED DIMENSIONS. /\ AT EXHAUST END DOOR ORAwwc REwsION DOOR TNDafl ANGLE PROiECf10N 4 FT.CLEARANCE - 05DEC2022 NEW DRAWING AKH KOH L ER. A AT EXHAUST END A 11JAN2029 A-4 PARALLEL UNIT WAS SINGLE UNIT' MIUOR 0- D SEES EET AKH INTAKE TO B 14FEB2023 (C-8,7)(C-2)3 FT.WAS 5 F.;SEE SHEET 4 AKH CHARACTEFUSTICS COMPLY VATH sr•,F.OAO SHEET s¢E:B SHEET 5 OF 5 BE 10 Ff. FROM EXHAUST Tom' 26RCA OPAN"� 7 DATE: DIMENSION PRINT,26RCA PARALLEL UMT APPRovm:SEE PIM OSDEC2022 CONRGURATION SYSTEM DWCNo,ADV-9919 8 7 6 5 4 TH6OMVAHOWDE910N MID OETALIS KOHIEH W.PWPERTY AIID MUST NOf BE USED E%CEPIINMMETONWRNNONIERW.WORKNLMI OFMLONORWYENIIONPRERESERV£O.