HomeMy WebLinkAbout52555-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52555 Date: 12/16/2025
Permission is hereby granted to:
Goed Intent LLC
58 South Path
Calverton, NY 11933
To:
Construct a new single-family dwelling as applied for per SCHD approval.
Premises Located at:
1135 Wildberry Ln,Southold, NY 11971
SCTM#51.-3-12.15
Pursuant to application dated 09/15/2025 and approved by the Building Inspector.
To expire on 12/16/2027.
Contractors:
Required Inspections:
Fees:
Single Family Dwelling-NEW $3,089.50
CO Single Family Dwelling-New $100.00
Total S3,199.50
Building Inspector
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 lilt)s://www.soutlioldtowiroayi2
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only �4
0 .
PERMIT N0.,5 5 515 Building Ins ector„
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,an Cz
Owner's Authorization form(Page 2)shall be completed.
Date:
908/ /2025
OWNER(S)OF PROPERTY:
Name:GOED Intent LLC SCTM#1000-51-03-12.15
Project Address: 1135 WiIdberry Lane, Southold NY 11971
Phone#: Email:nrbobby007@yahoo.com
Mailing Address:
950-7 Old Medford Avenue, Medford NY 11763
CONTACT PERSON:
Name:Stephen Cubells
Mailing Address:950-7 Old Medford Avenue, Medford NY 11763
Phone#:(631)767-0294 Email:stephen@allislandcleaning.com
DESIGN PROFESSIONAL INFORMATION:
Name:Richard Searles Architect, P.C.
Mailing Address:PO Box 286, Wading River NY 11792
Phone#:(631)744-2852 Email:rsearles@rs-architect.net
CONTRACTOR INFORMATION:
Name:All Island Cleaning / Stephen Cubells
Mailing Address:950-7 Old Medford Avenue, Medford NY 11763
Phone#:(631)767-0294 1 Email:stephen@allislandcleaning.com
DESCRIPTION OF PROPOSED CONSTRUCTION
MNew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other $800,000.00
Will the lot be re-graded? ®Yes ❑No Will excess fill be removed from premises? ❑Yes M No
1
PROPERTY INFORMATION
Existing use of property: Res vacant land Intended use of property: Residential Home
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? *Yes ONO IF YES, PROVIDE A COPY.
@ Check Box Aker Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 2.36 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in buildings}for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section WAS of the New York State Penal Law.
Application Submitted By(print n :Stephe Cubells ®Authorized Agent ❑Owner
Signature of Applicant: Date: 9/08/2025
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Stephen Cubells being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the Authorized Agent
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
/J
day of ,20 L
Notary NE 4D
Pu4ri
"V, STATE
PROPERTY OWNER AUTHORIZATION " ``
�' itsSrifoikcounty,«v
(Where the applicant is not the owner) C: OIDY6355279
I, residing at
Bobby Nadeau 58 South Path, Calvert i
NY, 11933 day hereby authorize Stephen Cubells to apply on
y befl f to the Tow of So thold Building Department for approval as described herein.
9/08/2025
Owner's Signature Date
Bobby Nadeau
Print Owner's Name
2
C�( Generated by Scheck-Web Software
J Compliance Certificate
Project Goed Intent -Wildberry Lane
Energy Code: 2018 IECC
Location: Southold, New York
Construction Type: Single-family
Project Type: New Construction
Orientation: Bldg. faces 0 deg. from North
Conditioned Floor Area: 3,518 ft2
Glazing Area 19%
Climate Zone: 4 (5572 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
1135 Wildberry Lane Goed Intent LLC Richard Searles
Southold, New York 11971 58 South Path Richard Searles Architect P.C.
Calverton, New York 11933 P.O. Box 286
Wading River, New York 11792
631 744-2852
rsearles@rs-architect.net
Compliance: 2.4%Better Than Code Maximum UA: 501 Your UA: 489 Maximum SHGC: 0.40 Your SHGC: 0.31
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. IE::.ach slab on.-grade
assembly in the sped-fled climate zone must meet the miniirnum energy code insulation R-value and depth requirements.
Prop.Envelope Assemblies
Gross Area
Cavity Cont. Prop.
Perimeter
Ceiling: Flat Ceiling or Scissor Truss 2,077 49.0 0.0 0.026 0.026 54 54
Wall 1:Wood Frame, 16"o.c. 790 21.0 0.0 0.057 0.060 37 39
Orientation: Front
Door 1 front: Glass Door(over 50%glazing)
SHGC: 0.24 50 0.290 0.320 14 16
Orientation: Front
Window 1:Wood Frame
SHGC: 0.32 94 0.290 0,320 27 30
Orientation: Front
Wall 2:Wood Frame, 16" D.C. 853 21.0 0.0 0.057 0.060 45 47
Orientation: Left side
Door 2 fixed: Glass Door(over 50%glazing)
SHGC: 0.26 21 0.333 0.320 7 7
Orientation: Left side
Window 2:Wood Frame
SHGC: 0.32 45 0.290 0.320 13 14
Orientation: Left side
Wall 3:Wood Frame, 16" o.c. 824 21.0 0.0 0.057 0.060 30 31
Orientation: Back
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 1 of10
a
Cont.Gross Area
Cavity • • -• Prop.
Perimeter
Door 3: Glass Door(over 50%glazing)
SHGC: 0.32 250 0.330 0.320 83 80
Orientation: Back
Window 3:Wood Frame
SHGC: 0.32 53 0.290 0.320 15 17
Orientation: Back
Wall 4:Wood Frame, 16" o.c. 800 21.0 0.0 0.057 0.060 39 41
Orientation: Right side
Door 4 fixed: Glass Door(over 50%glazing)
SHGC: 0.26 21 0.330 0.320 7 7
Orientation: Right side
Window 4:Wood Frame
SHGC: 0.32 101 0.290 0.320 29 32
Orientation: Right side
Basement Wall:Solid Concrete or Masonry
Orientation: Unspecified
Wall height: 8.2' 1,466 0.0 10.0 0.061 0.059 89 86
Depth below grade: 7.2'
Insulation depth: 8.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed,building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandato re uirements list d in the REScheck Inspection Checklist.
Name-Title Date
Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24
Data filename: Page 2 of10
w
REScheck Software Version a REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Re .ID
1103.1,03.2 documentation on drawings
and
111Complies
Does Not
I[PR1]1 energy code compliance for the ❑Not Observable
i 1611" building envelope.Thermal
envelope represented on ❑Not Applicable
'construction documents.
103.1, Construction drawings and ❑ amplies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. '[]Not Observable
Systems serving multiple ❑Not Applicable
,dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is. Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
MY" Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
-Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 3 of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Re .ID
402.1.1 Conditioned basement wall R- R- OCornplies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values.
t „ insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zo
ne
e 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions.
t, ❑Not Observable
❑Not Applicable
402.2.9 'Conditioned basement wall ft ft ❑Cnmphes See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall. ;[]Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
d �❑Not Observable
minimum of 6 in. below grade.
I❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12]z controls installed. ❑Does Not
4 QNot Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24
Data filename: Page 4 of10
"5ectlon Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Re .LD
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3, [-]Not Observable
402.5
❑
[FR2]1 Not Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
Al,; with the NFRC test procedure or ❑Not Observable
taken from the default table.
[]Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
a instructions. '❑Not Observable
i❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440: ❑Not Observable
or has infiltration rates per NFRC ❑Not Applicable
400 that do not exceed code
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate s2.0 cfm ;❑Not Observable
leakage at 75 Pa. ❑Not Applicable
403.3.1 Supply and return ducts in attics !❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_ ❑Not Observable
R-6 where< 3 inches. Supply and ❑Not Applicable
return ducts in other portions of
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.2 'Ducts, air handlers and filter '❑Complies
[FR13]1 boxes are sealed with ❑Does Not
joints/seams compliant with ❑Not Observable
International Mechanical Code or ❑Not Applicable
International Residential Code,as
applicable.
403.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
d;k,, :[]Not Observable
❑Not Applicable
pipingconveying
y g R R- ❑Complies
[F 17]z above 105 °For chilled fluids []Does Not
µX below 55°F are insulated to >_R- ❑Not Observable
3.
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- OComplies
[FR18] _R-3. Does Not
f ❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ElComplies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 5 of10
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 1,Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 6 of10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Re .1D
303.1 ;All installed insulation is labeled ❑Complies
[IN13]2 ;or the installed R-values ❑Does Not
provided.
, I❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a' R- R- ❑Complies See the Envelope 4ssemblies
402.2.5, mass wall with at least Y2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 I Wall insulation is installed per `❑ omplies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 7 of10
Section Plans Verified ����Corn
# Final Inspection Provisions Value plies? Comments/Assumptions
& Rye .ID
402.1.1, (Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ woo d ❑Does Not ;table for values.
402.2.2, ❑ Steel ❑ Steel []Not Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every ❑Not Observable
300 ft2.
Not Applicable
402.2.3 'Vented attics with air permeable ❑Complies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable
extends over insulation.
❑Not Applicable
402.2.4 'Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation >-R-value of the ❑Does Not
adjacent assembly. [ Not Observable
❑Not Applicable
402.4.1.2 (Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 '❑Complies
[FI27]1 determine air leakage with ft2 ft2 j❑Does Not
either: Rough-in test:Total ❑Not Observable
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
,leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
i[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2.1 'Air handler leakage designated :❑complies
[FI24]1 j by manufacturer at<=2%of ❑Does Not
design air flow.
[]Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[Flg]2 installed for control of primary ❑Does Not
heating and cooling systems and I❑Not Observable
initially set by manufacturer to
code specifications. �'❑Not Applicable
403.1.2 Heat pump thermostat installed ElComplies
[1`110]2 on heat pumps. ❑Does Not
I❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water []Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 8 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Ike .ID
403.6.1 'All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed ! ❑Does Not
HVAC equipment meet efficacy "[]Not Observable
and air flow limits per Table ❑Not Applicable
R403.6.1.
403.2 Hot water boilers supplying heat ;❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback [—]Not Observable
control to lower boiler water ❑Not Applicable
temperature based on outdoor
temperature,
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply ❑Not Applicable
pipe. Gravity and thermos-
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at se t- oint temperature and
P P
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically ❑Not Observable
adjust the energy input to the ❑Not Applicable
heat tracing to maintain the
desired water temperature in the
piping.
403.5.2 Demand recirculation water ❑IDo s Not pies
[F130]2 systems have controls that
manage operation of the pump []Not Observable
and limit the temperature of the ❑Not Applicable
water entering the cold water
piping to <= 104°F.
403.5.4 Drain water heat recovery units ❑Complies
[FI31]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side ❑Not Observable
pressure loss of drain water heat ❑Not Applicable
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 90%or more of permanent ❑Complies
[F16]1 fixtures have high efficacy lamps. ❑Does Not
[]Not Observable
❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑C'omplies
[F123]3 no continuous pilot light. ❑Does Not
[]Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies
[F17]2 ,❑Does Not
[]Not Observable
❑Not Applicable
1 1 JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24
Data filename: Page 9 of10
Section Plans Verified! Field Verified
Final Inspection Provisions Value Value Complie:s?:] ments/Assumptions,
ARe I !7�-7
AAD 30,3.3 Manufacturer manuals for Momplies
[FI1813 mechanical and water heating Not
systems have been provided. []Not Observable
43Not Applicable
Additional Comments/Assumptions:
11 High Impact Jier 1 2 ledl,um Impact (Tier 2) 3 1 Low Impact('ter 3)
..................
Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24
Data filename: Page 10 of10
Effidency Certificate
No= OM
Above-Grade Wall 21.00
Below-Grade Wall 10.00
Floor 0.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
IMMEMMEMEMEMEM=�
Window 0.29 0.32
Door 0.33 0.32
Heating System:,
Cooling System:
Water Heater:
Name• Date•
Comments
df iRSA
SURVEY OF I<
? - LOT 9 w�
MdP OF
}yII,DBERRY FIELDS
EXCAVATION INSPECTION REQUIRED SpiII3D � NITUATS Jc,
SOUTHOLDTOWN OF SOTHOW
_
FOR SANITARY SYSTEM SUFFOLK COUNTY.NEW YORK
Ij€ S.C.TAX No.1000-51-05=12.15 S
Y HEALTH DEPARTMENT � JANuaR'i' 22
zosz
UAI ICo a Meye[
ceaem.n m: ilWdsn
PToyou�Ilk
-��, eisEdp uN�o Tnix pwwxu coMENv Fo I ,
"g Goes Intent
, .a LLCM
}
i vKAMI svim.vl ® ama al--- L73f W ia.e
lutkw
SS.C.T.A��N.Y.
1000 i1pf13-17.1f
�cwm
pleat 101 - �' $ REvatoc
rr
�u t L561 O FOR CCNO
13 3` 3 - .. xsw /uA� .is.wnw In..l e•eN-weum Pwla �. Mao
�t�.� s€y�r`�`.' eIVIM[W e'N,x Y Npe 51RR11 ewN ee@Ix OVA4 s-15-701f
p 5�r e � rWwsm r m.x.eua exmaLS nx xaer ua exmm mue `} 2 WEl�iSEo]-t�zo]s
a4 s± AIl€HIFbgNG fQIP
� =- NOtICEN7 FOR `
FL 29-06 5
J� s
j i RG 7-10-2o1f
NOi7CE#7 FOR
TAB' TM� NJI C r.0 CEN-]TREATMENT SYSTEM R�2{-0F{S
PROPOSED SEPTIC M DETAIL I
p
aA e�sm se�Rea I�Eksf
--{`"Y%S N_ $ maw X€.
Lasezaxe
::� +z..a�.sw
o
3 a , FUJICLEAN I/A OWTS a
.SUFFOLN COUNTY CEPARTRENT OF I$EALTN SERVICES
S]y.25'15
_piSBRYi�SiNiNT PERMIT FOR APPROVAL OF CON5FRUCTION FOR A "
ADW"AwoS SINGLE FAMILY RESIDENCE ONLY
-
SRE r.a w •vaw.svx ww� - roar.x.I v®w �e
nvvelo avJ¢Iuml Nnp>m vrt iu�m.c°�iv iru®..�vwwv.a.ocm va REF_
j� - -_
DATE VIM KZ,RFF_Id0 R..k.a.'S 7TTtE _.
n
FOR MAXIMUM OF _.6 ..BEDROOMS rrARY .:
1 EXPIRES THREE YEARS FROM DATE OF APPROVAL 57TF` PI.AN
Sp-1