Loading...
HomeMy WebLinkAbout52555-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52555 Date: 12/16/2025 Permission is hereby granted to: Goed Intent LLC 58 South Path Calverton, NY 11933 To: Construct a new single-family dwelling as applied for per SCHD approval. Premises Located at: 1135 Wildberry Ln,Southold, NY 11971 SCTM#51.-3-12.15 Pursuant to application dated 09/15/2025 and approved by the Building Inspector. To expire on 12/16/2027. Contractors: Required Inspections: Fees: Single Family Dwelling-NEW $3,089.50 CO Single Family Dwelling-New $100.00 Total S3,199.50 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 lilt)s://www.soutlioldtowiroayi2 Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �4 0 . PERMIT N0.,5 5 515 Building Ins ector„ Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Cz Owner's Authorization form(Page 2)shall be completed. Date: 908/ /2025 OWNER(S)OF PROPERTY: Name:GOED Intent LLC SCTM#1000-51-03-12.15 Project Address: 1135 WiIdberry Lane, Southold NY 11971 Phone#: Email:nrbobby007@yahoo.com Mailing Address: 950-7 Old Medford Avenue, Medford NY 11763 CONTACT PERSON: Name:Stephen Cubells Mailing Address:950-7 Old Medford Avenue, Medford NY 11763 Phone#:(631)767-0294 Email:stephen@allislandcleaning.com DESIGN PROFESSIONAL INFORMATION: Name:Richard Searles Architect, P.C. Mailing Address:PO Box 286, Wading River NY 11792 Phone#:(631)744-2852 Email:rsearles@rs-architect.net CONTRACTOR INFORMATION: Name:All Island Cleaning / Stephen Cubells Mailing Address:950-7 Old Medford Avenue, Medford NY 11763 Phone#:(631)767-0294 1 Email:stephen@allislandcleaning.com DESCRIPTION OF PROPOSED CONSTRUCTION MNew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $800,000.00 Will the lot be re-graded? ®Yes ❑No Will excess fill be removed from premises? ❑Yes M No 1 PROPERTY INFORMATION Existing use of property: Res vacant land Intended use of property: Residential Home Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? *Yes ONO IF YES, PROVIDE A COPY. @ Check Box Aker Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 2.36 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings}for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section WAS of the New York State Penal Law. Application Submitted By(print n :Stephe Cubells ®Authorized Agent ❑Owner Signature of Applicant: Date: 9/08/2025 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Stephen Cubells being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the Authorized Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this /J day of ,20 L Notary NE 4D Pu4ri "V, STATE PROPERTY OWNER AUTHORIZATION " `` �' itsSrifoikcounty,«v (Where the applicant is not the owner) C: OIDY6355279 I, residing at Bobby Nadeau 58 South Path, Calvert i NY, 11933 day hereby authorize Stephen Cubells to apply on y befl f to the Tow of So thold Building Department for approval as described herein. 9/08/2025 Owner's Signature Date Bobby Nadeau Print Owner's Name 2 C�( Generated by Scheck-Web Software J Compliance Certificate Project Goed Intent -Wildberry Lane Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area: 3,518 ft2 Glazing Area 19% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 1135 Wildberry Lane Goed Intent LLC Richard Searles Southold, New York 11971 58 South Path Richard Searles Architect P.C. Calverton, New York 11933 P.O. Box 286 Wading River, New York 11792 631 744-2852 rsearles@rs-architect.net Compliance: 2.4%Better Than Code Maximum UA: 501 Your UA: 489 Maximum SHGC: 0.40 Your SHGC: 0.31 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. IE::.ach slab on.-grade assembly in the sped-fled climate zone must meet the miniirnum energy code insulation R-value and depth requirements. Prop.Envelope Assemblies Gross Area Cavity Cont. Prop. Perimeter Ceiling: Flat Ceiling or Scissor Truss 2,077 49.0 0.0 0.026 0.026 54 54 Wall 1:Wood Frame, 16"o.c. 790 21.0 0.0 0.057 0.060 37 39 Orientation: Front Door 1 front: Glass Door(over 50%glazing) SHGC: 0.24 50 0.290 0.320 14 16 Orientation: Front Window 1:Wood Frame SHGC: 0.32 94 0.290 0,320 27 30 Orientation: Front Wall 2:Wood Frame, 16" D.C. 853 21.0 0.0 0.057 0.060 45 47 Orientation: Left side Door 2 fixed: Glass Door(over 50%glazing) SHGC: 0.26 21 0.333 0.320 7 7 Orientation: Left side Window 2:Wood Frame SHGC: 0.32 45 0.290 0.320 13 14 Orientation: Left side Wall 3:Wood Frame, 16" o.c. 824 21.0 0.0 0.057 0.060 30 31 Orientation: Back Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 1 of10 a Cont.Gross Area Cavity • • -• Prop. Perimeter Door 3: Glass Door(over 50%glazing) SHGC: 0.32 250 0.330 0.320 83 80 Orientation: Back Window 3:Wood Frame SHGC: 0.32 53 0.290 0.320 15 17 Orientation: Back Wall 4:Wood Frame, 16" o.c. 800 21.0 0.0 0.057 0.060 39 41 Orientation: Right side Door 4 fixed: Glass Door(over 50%glazing) SHGC: 0.26 21 0.330 0.320 7 7 Orientation: Right side Window 4:Wood Frame SHGC: 0.32 101 0.290 0.320 29 32 Orientation: Right side Basement Wall:Solid Concrete or Masonry Orientation: Unspecified Wall height: 8.2' 1,466 0.0 10.0 0.061 0.059 89 86 Depth below grade: 7.2' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed,building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandato re uirements list d in the REScheck Inspection Checklist. Name-Title Date Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24 Data filename: Page 2 of10 w REScheck Software Version a REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Re .ID 1103.1,03.2 documentation on drawings and 111Complies Does Not I[PR1]1 energy code compliance for the ❑Not Observable i 1611" building envelope.Thermal envelope represented on ❑Not Applicable 'construction documents. 103.1, Construction drawings and ❑ amplies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. '[]Not Observable Systems serving multiple ❑Not Applicable ,dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is. Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable MY" Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) -Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1 Conditioned basement wall R- R- OCornplies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. t „ insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zo ne e 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. t, ❑Not Observable ❑Not Applicable 402.2.9 'Conditioned basement wall ft ft ❑Cnmphes See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ;[]Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a d �❑Not Observable minimum of 6 in. below grade. I❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]z controls installed. ❑Does Not 4 QNot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24 Data filename: Page 4 of10 "5ectlon Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .LD 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, [-]Not Observable 402.5 ❑ [FR2]1 Not Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not Al,; with the NFRC test procedure or ❑Not Observable taken from the default table. []Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not a instructions. '❑Not Observable i❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440: ❑Not Observable or has infiltration rates per NFRC ❑Not Applicable 400 that do not exceed code limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm ;❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.3.1 Supply and return ducts in attics !❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where< 3 inches. Supply and ❑Not Applicable return ducts in other portions of the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 'Ducts, air handlers and filter '❑Complies [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with ❑Not Observable International Mechanical Code or ❑Not Applicable International Residential Code,as applicable. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not d;k,, :[]Not Observable ❑Not Applicable pipingconveying y g R R- ❑Complies [F 17]z above 105 °For chilled fluids []Does Not µX below 55°F are insulated to >_R- ❑Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- OComplies [FR18] _R-3. Does Not f ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ElComplies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1,Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Re .1D 303.1 ;All installed insulation is labeled ❑Complies [IN13]2 ;or the installed R-values ❑Does Not provided. , I❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a' R- R- ❑Complies See the Envelope 4ssemblies 402.2.5, mass wall with at least Y2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 I Wall insulation is installed per `❑ omplies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 7 of10 Section Plans Verified ����Corn # Final Inspection Provisions Value plies? Comments/Assumptions & Rye .ID 402.1.1, (Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ woo d ❑Does Not ;table for values. 402.2.2, ❑ Steel ❑ Steel []Not Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑Not Observable 300 ft2. Not Applicable 402.2.3 'Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 'Attic access hatch and door R- R- ❑Complies [FI3]1 insulation >-R-value of the ❑Does Not adjacent assembly. [ Not Observable ❑Not Applicable 402.4.1.2 (Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 '❑Complies [FI27]1 determine air leakage with ft2 ft2 j❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total ,leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies i[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2.1 'Air handler leakage designated :❑complies [FI24]1 j by manufacturer at<=2%of ❑Does Not design air flow. []Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Flg]2 installed for control of primary ❑Does Not heating and cooling systems and I❑Not Observable initially set by manufacturer to code specifications. �'❑Not Applicable 403.1.2 Heat pump thermostat installed ElComplies [1`110]2 on heat pumps. ❑Does Not I❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water []Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Ike .ID 403.6.1 'All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ! ❑Does Not HVAC equipment meet efficacy "[]Not Observable and air flow limits per Table ❑Not Applicable R403.6.1. 403.2 Hot water boilers supplying heat ;❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback [—]Not Observable control to lower boiler water ❑Not Applicable temperature based on outdoor temperature, 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply ❑Not Applicable pipe. Gravity and thermos- syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at se t- oint temperature and P P no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the ❑Not Applicable heat tracing to maintain the desired water temperature in the piping. 403.5.2 Demand recirculation water ❑IDo s Not pies [F130]2 systems have controls that manage operation of the pump []Not Observable and limit the temperature of the ❑Not Applicable water entering the cold water piping to <= 104°F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side ❑Not Observable pressure loss of drain water heat ❑Not Applicable recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90%or more of permanent ❑Complies [F16]1 fixtures have high efficacy lamps. ❑Does Not []Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑C'omplies [F123]3 no continuous pilot light. ❑Does Not []Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [F17]2 ,❑Does Not []Not Observable ❑Not Applicable 1 1 JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Goed Intent -Wildberry Lane Report date: 02/20/24 Data filename: Page 9 of10 Section Plans Verified! Field Verified Final Inspection Provisions Value Value Complie:s?:] ments/Assumptions, ARe I !7�-7 AAD 30,3.3 Manufacturer manuals for Momplies [FI1813 mechanical and water heating Not systems have been provided. []Not Observable 43Not Applicable Additional Comments/Assumptions: 11 High Impact Jier 1 2 ledl,um Impact (Tier 2) 3 1 Low Impact('ter 3) .................. Project Title: Goed Intent-Wildberry Lane Report date: 02/20/24 Data filename: Page 10 of10 Effidency Certificate No= OM Above-Grade Wall 21.00 Below-Grade Wall 10.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): IMMEMMEMEMEMEM=� Window 0.29 0.32 Door 0.33 0.32 Heating System:, Cooling System: Water Heater: Name• Date• Comments df iRSA SURVEY OF I< ? - LOT 9 w� MdP OF }yII,DBERRY FIELDS EXCAVATION INSPECTION REQUIRED SpiII3D � NITUATS Jc, SOUTHOLDTOWN OF SOTHOW _ FOR SANITARY SYSTEM SUFFOLK COUNTY.NEW YORK Ij€ S.C.TAX No.1000-51-05=12.15 S Y HEALTH DEPARTMENT � JANuaR'i' 22 zosz UAI ICo a Meye[ ceaem.n m: ilWdsn PToyou�Ilk -��, eisEdp uN�o Tnix pwwxu coMENv Fo I , "g Goes Intent , .a LLCM } i vKAMI svim.vl ® ama al--- L73f W ia.e lutkw SS.C.T.A��N.Y. 1000 i1pf13-17.1f �cwm pleat 101 - �' $ REvatoc rr �u t L561 O FOR CCNO 13 3` 3 - .. xsw /uA� .is.wnw In..l e•eN-weum Pwla �. Mao �t�.� s€y�r`�`.' eIVIM[W e'N,x Y Npe 51RR11 ewN ee@Ix OVA4 s-15-701f p 5�r e � rWwsm r m.x.eua exmaLS nx xaer ua exmm mue `} 2 WEl�iSEo]-t�zo]s a4 s± AIl€HIFbgNG fQIP � =- NOtICEN7 FOR ` FL 29-06 5 J� s j i RG 7-10-2o1f NOi7CE#7 FOR TAB' TM� NJI C r.0 CEN-]TREATMENT SYSTEM R�2{-0F{S PROPOSED SEPTIC M DETAIL I p aA e�sm se�Rea I�Eksf --{`"Y%S N_ $ maw X€. Lasezaxe ::� +z..a�.sw o 3 a , FUJICLEAN I/A OWTS a .SUFFOLN COUNTY CEPARTRENT OF I$EALTN SERVICES S]y.25'15 _piSBRYi�SiNiNT PERMIT FOR APPROVAL OF CON5FRUCTION FOR A " ADW"AwoS SINGLE FAMILY RESIDENCE ONLY - SRE r.a w •vaw.svx ww� - roar.x.I v®w �e nvvelo avJ¢Iuml Nnp>m vrt iu�m.c°�iv iru®..�vwwv.a.ocm va REF_ j� - -_ DATE VIM KZ,RFF_Id0 R..k.a.'S 7TTtE _. n FOR MAXIMUM OF _.6 ..BEDROOMS rrARY .: 1 EXPIRES THREE YEARS FROM DATE OF APPROVAL 57TF` PI.AN Sp-1