Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52115-Z
Of souryo`o Town of Southold * * P.O. Box 1179 53095 Main Rd 4'oouNv.0 Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46508 Date: 09/18/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 19620 Soundview Ave Southold, NY 11971 Sec/Block/Lot: 51.-3-12.3 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 06/26/2025 Pursuant to which Building Permit No. 52115 and dated: 07/18/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for. The certificate is issued to: Head of Harbor LI LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52115 08/11/2025 PLUMBERS CERTIFICATION: Aut on ed ignature ho�aofsoaryolo TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE count SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52115 Date: 07/18/2025 Permission is hereby granted to: Head of Harbor LI LLC 2631 Merrick Rd Bellmore, NY 11710 To: Install a generator accessory to a single-family dwelling as applied for. Must maintain a minimum side and rear yard setback of 25 feet. Premises Located at: 19620 Soundview Ave, Southold, NY 11971 SCTM#51.-3-12.3 Pursuant to application dated 06/26/2025 and approved by the Building Inspector. To expire on 07/18/2027. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessory $100.00 ELECTRIC -Residential $100.00 Total $325.00 I zo- Building Inspector OF SOUl��l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • �Q Southold,NY 11971-0959 �OIyCQU ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Head of Harbor LI LLC Address: 19620 Soundview Ave City:Southold St: NY Zip: 11971 Building Permit#: 521 15 section: 51 Block: 3 Lot: 12.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Brilliant Electric License No: 40896ME SITE DETAILS Office Use Only Indoor W Basement r Service (— Solar 1- Outdoor 1st Floor (— Pool F Spa 177— Renovation r 2nd Floor r Hot Tub F Generator (✓ Survey r Attic r Garage ri Battery Storage [— INVENTORY Service 1 ph I-` Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph (— Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 26kW Generac Generator w/ 200A Transfer Switch Supplying One Panel Notes: Generator Inspector Signature: X Date: August 11, 2025 Sean Devlin Electrical Inspector sean.devlin(c-town.southold.nv.us 196208ou ndviewAveGenerator OF SO//TyO� �2 - # TOWN OF SOUTHOLD BUILDIN DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY . [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS. aj2A DATE INSPECTOR *OP SOUIyOIo TOWN OF SOUTHOLD BUILDING DEPT.' cou 631-765-1802 w I -N-s P «� [ ]. FOUNDATION.1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 6 . ] FIREPLACE & CHIMNEY [ '] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] .ELECTRICAL (ROUGH) [ ] ELECTRICAL'(FINAL)- [ ] CODE VIOLATION [ ]. PRE C/O [ ]' RENTAL REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) --------------- -------------------------------------- -- ----------- FOUNDATION (2ND) cn RO UGH FRAMING & PLUMBING INSULATION PER N. Y. STATE ENERGY CODE 4V%--/— FLNAL --—-------- ------- ADDITIONAL COMMENTS c ............ --------------- rn ---------- ............ .......... ........... o�s�fFOr�coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT yam, yz Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.aov Date Received APPLICATION FOR BUILDING PERMIT E C E Q V E D For Office Use Only ✓� PERMIT No. 5 ol I Building Inspector: JUN 2 6 2025 Applications and f6rms.rriu"st be filled outin their entirety Incomplete :, Building Department applications will,not be atceDied Where-,the:Applicant is not the owner,an Town Of Southold Owner's,Authorization-forin'(Page,2)shall be zompleted� Date: OWNERS)OF PROPERTYO Name: NeA SCTM #10007 - Project Address- q-`7 - Phone#: �� Email: Mailing Address: 7 j CONTACT PERSON Name: a - , I_A-A /Jc� Mailing Address: e () �JK 3v 9Lj�° Phone#: 3 Email: DESIGN PROFESSIONAL INFORMATION Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: usl C111_4 tIIL°. . _ Mailing Address: Phone Email: #:� _Sr�:3�3.�f.._LdCI---�� -- -• - DESCRIPTION OF;PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other__Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes El No 1 " PROPERTMINFORMATION Existing use of property: Intended use of property: - AJEW axjgneo - - - Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES; PROVIDE A COPY. D ChecIC:BOX After Reading The-ow -6'66ctor/des�g i professional i3 responsible for all'dramage"and storm:water issues as provided by Chapter 236 of the Town t de,,APPLICATION IS HEREBY'MADE to the;!Bwlding.Department,fo.r the issuance of aBuildmg Psrmrt pursuant to`,the Bwldmg,2one ^Ordinance of the Town of Southold,Suffolk;County,New York and other,applicatile Laws,Ordinances o'r;Regulations,for tfie,construction of,l uildings, . or f&,iemoval.or PP „g, P y Pp ding code,, houstn additions, code andresulat ons and to atlme aulthor ed ns'ecto s onedrem ses anldantbuild ns is fornecessa a ins ectionls.IFalse statements made herein are g;- , g p p gI ) o ry P punishable'as a Class,A misdemeanor,pursuant to Section 210 45 of the New York State Penal;Caw _X. Application Submitted By(print name): ❑Authorized Agent 9fOwner Signature of Applicant: Date: STATE OF NEW YORK) S: COUNTY OF ) { �1 cl I`11-t I Or lq n y being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the �wf1 e /L (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 6 day ofC , 20 Z� Notary Public ADM GA AG E Ol CHOWS H Notary Public • State of New York No. 01 OL0019699 PROPERTY OWNER AUTHORIZATIO Qualified in Suffolk County My Comm. Expires Jan. 10, 2028 (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 gUFFO(�C BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 'y�0� �►ao� Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: ,e1LUAATT Electrician's Name: License No.: Zfog f(p -M E Elec. email: 0) lam. Elec. Phone No: _ S - ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: d 0 S&0,,U,8Uj&1AclE Cross Street: Phone No.: Bldg.Permit#: S a I ( `.� email: Tax Map District: 1000 Section:p / 00 Block: 03.vp Lot:pi 3 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): EN�Zr9-T(�� Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION N I LC75E R)," LANE NOTE: NO NELLS iCP 1Y NO WATER ON LOT W I T I N I O T. O Q I VACANT LAND i�iZOi= i�TY > V I t LAND N/F TRIBERRY FIELD5 LLG Z f1 510054'45"E B_6ZOJ 577.aQ1 I� GE — 8911 _--_---— _ _-- — PROPOSED WATERSaUPPLYl�- 0 B_67s EL 65.5 ------------ -� \\\\ \� s— 64.0 \n��i+srj \\\\\\ i .._� PR/DR7.i® o' `` \ �N I z ��� S �� 6s.16 0 ----�. — ��raRr �� N Kid i o Q ' OrGi3�2b1' , / ILI } 69 a I o' ; H-67D4 % V 1 p 33� Q a 11 �% I OEL 61.1 El-65.01 _--- DRIVEWAYe6 I �\ L. Q o % m 66 rr ^— 6es�osEv uMDl i6ROuriD ELECTR�c \ m_ It s8 N10°04'55"W \ a ePr.D)�R PENCE 55q.74' I 3.90 29 25 E IMPROVED LOT LAND N/F 5UFFOLK COUNTY AND COUNTY OF 5UFFOLK OLD NORTH ROAD BARN LLG FARM LAND PUBLIC WATER PLOT PLAN SCALE. V -50'-0. Rooj COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES REQUIRE:Q AND CONDITIONS OF APPROVED AS NOTED SOUTHOLDTOWNZBA DATE:-7-16" 5 a I s SOUTHOLD TOM PLANNING BOARD $ BR# SOUTHOLD TOWN TRUSTEES FED a o�5.U 0 BY N.Y.S,DEC NOTIFY BUILDING DEPARTMENT AT SOUTHOLD HPG 631-765-1802 8AM TO 4PM FOR THE SCHD FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION ELECTRICAL FINAL-CONSTRUCTION MUST INSPECTION REQUIRED BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS KOHLER. Models: 26RCA(L) Multi-Fuel LPG/Natural Gas 09001 Standard Features 4 KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions (with optional Model RXf). o Electronic speed control responds quickly to varying demand. o OnCue®Plus Generator Management System for remote 4 monitoring is included with the generator. " • Kohler Command PRO Engine Features o Kohler Command PRO@ OHV engine with hydraulic valve lifters for reliable performance without routine valve Kpw adjustment or lengthy break-in requirements. • Designed for Easy Installation The Kohler® Advantage o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. • High Quality Power o Fuel and electrical connections through the enclosure wall Kohler home generators provide advanced voltage and eliminate the need for stub-ups through the base. frequency regulation along with ultra-low levels of harmonic o Customer connection terminal block located near the distortion for excellent generator power quality to protect your controller allows easy access for field wiring. valuable electronics. o Designed for outdoor installation only. • Premium 5-yr/2000-hr Limited Warranty Included o Approved for stationary standby applications in locations Kohler is known for extraordinary reliability and performance. served by a reliable utility source (on-grid). Kohler's premium limited warranty covers parts,labor,and travel for the full warranty period. • Certifications • Powerful Performance o Meets emission regulations for U.S. Environmental Exclusive Powerboost- technology provides excellent Protection Agency(EPA)with both natural gas and LPG. starting power.§ o UL 2200/cUL listed. o Accepted by the Massachusetts Board of Registration of • Aluminum Enclosure Plumbers and Gas Fitters. o Attractive aluminum enclosure allows installation as close o Meets 181 mph wind rating. as 18 inches from your home or small business.t • Exercise Modes o Enclosure panels can be removed without tools to allow o 90-second EcoExercise,unloaded,with system easy access for maintenance and service. diagnostics. Reduces fuel costs and minimizes sound • Camouflage Enclosures are available for single-phase units disruption. (optional).Go to KohlerGenerators.com/Mossyoak to view o Unloaded weekly exercise with complete system the available patterns. diagnostics (20 minutes) Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. o Unloaded full-speed exercise(20 minutes) o Loaded full-speed exercise (20 minutes; Model RXT ATS required) o Weekly, bi-weekly,or new monthly exercise intervals. • Model 26RCAL includes a model RXf automatic transfer switch.See last page for more details. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Model Alt Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles 26RCA 2F8 120/240 1 60 24/24 100 26/26 109 125 2 26RCAL 120/208 3 60 22/27 77 22/27 77 80 3 26RCA 2G8 120/240 3 60 22/27 67 22/27 67 80 3 277/480 3 60 22/27 34 22/27 34 40 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 powerfactor.The standby rating is applicable to variable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are In accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derate 4%per305 in(1000ft.)elevation above 153 m(500%).TEMPERATURE:Derate 21/oper 5.5°C(10°F)temperature increase above 16°C(60°F). Availability is subject to change without notice.The generator set manufacturer reserves the rightto change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator dealer for availability. § Check the appliance manufacturer's specifications for actual power requirements. Consult a Kohler®Power Systems professional to calculate your exact residential power system requirements. 1' Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-315 (26RCA) 4/23a Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator • Compliance with NEMA, IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field • Self-ventilated and dripproof construction. Leads,quantity 2F8 4 • Windings are vacuum-impregnated with epoxy varnish for 2G8 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H • Digital voltage regulator with±1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full • Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F8(4 lead) 39(60 Hz) 240 or 480 V,3 ph 2G8(12 lead) 63(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH1006 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 10.5:1 Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM 3600 Oil cooler Integral Max.engine power at rated rpm,kW(HP) § Kohler recommends the use of Kohler Genuine oil and filters. LPG 26.1 (36.4) Fuel Requirements Natural gas 24.5(33.0) Cylinder head material Aluminum Fuel System Valve material Steel/Stellite® Fuel types Natural Gas LPG Piston type and material Aluminum Alloy Fuel supply inlet 3/4 NPT Fuel supply pressure,kPa(in.H2O): Crankshaft material Heat Treated,Ductile Iron Natural gas 0.9-2.7(3.5-11) Governor:type Electronic LP 1.7-2.7(7-11) Frequency regulation,no load to full load Isochronous Frequency regulation,steady state ±0.5% Fuel Composition Limits* Nat.Gas LPG Air cleaner type Dry Methane,%by volume(minimum) 90 min. — Ethane,%by volume(maximum) 4.0 max. — Engine Electrical Propane,%by volume 1.0 max. 85 min. Engine Electrical System Propene,%by volume(maximum) 0.1 max. 5.0 max. Ignition system Electronic, C4 and higher,%by volume 0.3 max. 2.5 max. Capacitive Discharge Sulfur,ppm mass(maximum) 25 max. Starter motor rated voltage(DC) 12 Lower heating g value, MJ/m (Btu/ft ),(minimum) 33.2(890) 84.2(2260) Battery(purchased separately): * Contact your local dealer for suitability and rating derates based on Ground Negative fuel compositions outside these limits. Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 G4-315 (26RCA) 4/23a Fuel Pipe Size Operation Requirements Minimum Gas Pipe Size Recommendation,in.NPT Fuel Consumption,m3/hr.(cfh)@ 60Hz Pipe Length, Natural Gas LPG %Load Natural Gas LPG m(ft.) 290,000 Btu/hr. 322,500 Btu/hr. 100 8.2 (290) 3.6 (129) 8 (25) 1 3/4 75 6.7 (238) 3.1 (111) 15 (50) 11/4 1 50 5.1 (180) 2.4 (85) 30 (100) 1 1/4 1 25 3.9 (137) 1.8 (64) Exercise 1.9 (67) 0.9 (31) 46 (150) 1 1/4 1 Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) 61 (200) 1 1/2 1 1/4 LPG: 93 MJ/m3(2500 Btu/ft.3) Generator Set Sound Data LPG conversion factors: 8.58 ft.33 1 lb. 0.535 m 1 kg Model 26RCA sound levels are 56 dB(A)during engine exercise 36.39 ft.3 =1 gal. and 67 dB(A)during full-speed generator diagnostics and normal operation.* All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation parameters. RDC2 Controller Features • Exercise modes: o New 90-second Eco Exercise with complete system diagnostics(factory default setting) Voltage:Freq: 60.0 Hz 0 o Lowers fuel cost 0 0 o Minimizes sound disruption gg� o o In cold temperatures,limits condensation build-up in the crankcase ® W AM "' o Unloaded weekly 20-minute exercise with complete system diagnostics o Unloaded 20-minute full-speed exercise o Loaded 20-minute full-speed exercise(Model RXT ATS The RDC2 controller provides integrated control for the required) generator set, Kohler®Model RXT transfer switch, • Weekly, bi-weekly,or new monthly exercise intervals programmable interface module(PIM),and load shed kit. • Front-access mini USB connector for SiteTech'°" or USB • Membrane keypad: Utility connection o OFF,AUTO,and RUN pushbuttons • Integral Ethernet connector for Kohler®OnCue®Plus o Select and arrow buttons for access to system • Remote two-wire start/stop capability for optional connection configuration and adjustment menus of a Model RDT transfer switch • LED indicators for OFF,AUTO, and RUN modes • Diagnostic messages: Displays diagnostic messages for the • LED indicators for utility power and generator set source engine,generator, Model RXT transfer switch, programmable availability and ATS position (Model RXT transfer switch interface module(PIM),and load management device. required) • Maintenance reminders • LCD display: • System settings: o Two lines x 16 characters per line o System voltage,frequency,and phase o Backlit display with adjustable contrast for excellent o Voltage adjustment visibility in all lighting conditions o Measurement system, English or metric • Scrolling system status display: • ATS status (Model RXT ATS required): o Generator set status o Source availability o Voltage and frequency o ATS position (normal/utility or emergency/generator) o Engine temperature o Source voltage and frequency o Oil pressure • ATS control (Model RXT ATS required): o Battery voltage o Source voltage and frequency settings o Engine runtime hours o Engine start time delay • Date and time displays o Transfer time delays • Smart engine cooldown senses engine temperature o Voltage calibration • Digital isochronous governor maintains steady-state speed at o Fixed pickup and dropout settings all loads • Programmable Interface Module (PIM)status displays: • Digital voltage regulation: ±1.0% RMS no-load to full-load o Input status (active/inactive) • Automatic start with programmed cranking cycle o Output status (active/inactive) • Built-in 2.5 amp battery charger • Load control menus: • Programmable exerciser can be set to start automatically on o Load status any future day and time o Test function G4-315 (26RCA) 4/23a L KOHLER® PhoneKOHL 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Literature • Aluminum sound enclosure ❑ General maintenance literature kit • Battery cables ❑ Overhaul literature kit • Critical silencer ❑ Production literature kit • EPA certified fuel system Maintenance • Field-connection terminal block ❑ Maintenance kit(includes air filter,oil,oil filter, and • Fuel solenoid valve and secondary regulator spark plugs) • Line circuit breaker ❑ Premium 300 hour/2 year oil for fewer oil changes • Multi-fuel system,LPG/natural gas,field-convertible 26RCAL Model Package • Oil drain extension with shutoff valve ❑ 26RCAL with 200 amp service entrance-rated Model RXT • Oil level sensor with combined interface/load management board and corrosion-resistant NEMA3R aluminum enclosure • Oil pressure sensor Warranty • OnCue®Plus Generator Management System ❑ 7-Year Limited Warranty • Premium 5-year/2000 hour limited standby warranty. ❑ 10-Year Limited Warranty Covers parts,labor,and travel for the entire warranty period Warranties cover parts,labor,and travel for the entire • RDC2 generator set/ATS controller warranty period. • Rodent-resistant construction • Sound-deadening,flame-retardant foam per UL 94, class HF-1 Available Options Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120 VAC ❑ Carburetor heater, 120 VAC t Generator Set Dimensions and Weights ❑ Cold weather kit, 120 VAC t o Includes fuel regulator heater,oil and breather tube heaters. Generator Set Size,L x W x H: 1193 x 660 x 820 mm o QS model with factory-installed kit is available. E kit Shipping Weights: (47 x 26.0 x 32.3 in.) ❑ mer Emergency y stop 26RCA Generator Set: 283 kg(625 lb.) ❑ Programmable interface module(PIM) 26RCAL with 200 A RXT SE ATS: 304 kg(670 lb.) (provides 2 digital inputs and 6 relay outputs) * Battery heater is recommended below-170C(0°F). $ Do not use a carburetor heater with a cold weather kit. L t Cold weather kit is recommended below 0°C(320F). Enclosure Options (single-phase only) ❑ Mossy Oak@ camouflage enclosures available. Go to Koh lerGenerators.com/Mossyoak to see available H fmmm� patterns. Mossy Oak is a trademark used under license from Haas Outdoors,Inc.,by Kohler Co. Fuel System Accessories ❑ Flexible fuel line(included on CIS models) I W NOTE:Dimensions are provided for reference only and should not be used for planning installation.Contact your local dealer for more detailed information. DISTRIBUTED BY: ©2023 Kohler Co. All rights reserved. G4-315 (26RCA) 4/23a