Loading...
HomeMy WebLinkAbout51561-Z �oF s°uryo`o Town of Southold * * P.O. Box 1179 53095 Main Rd urarrr.N�' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46479 Date: 09/09/2025 THIS CERTIFIES that the building Swimming Pool with Fence-In Ground Location of Property: 4030 Nassau Point Rd Cutchogue, NY 11935 Sec/Block/Lot: 11 L-8-20 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/15/2024 Pursuant to which Building Permit No. 51561 and dated: 01/16/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to: William Isaacson,Patricia Isaacson Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51561 5/23/2025 PLUMBERS CERTIFICATION: i Auth ed ignature �,�owsouryo TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51561 Date: 01/16/2025 Permission is hereby granted to: William Isaacson 356 S Silver PWMRd Boca Raton, FL 33432 To: construct accessory in-ground swimming pool as applied for. Pool equipment must be provided with protection from vehicle impact. Premises Located at: 4030 Nassau Point Rd, Cutchogue, NY 11935 SCTM# 111.-8-20 Pursuant to application dated 11/15/2024 and approved by the Building Inspector. To expire on 01/16/2027. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total $400.00 B ' ing Inspector o��oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 OOUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: William Isaacson Address: 4030 Nassau Point Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 51561 Section: 1 1 1 Block: $ Lot: 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Platinum East Electric License No: ME-34091 SITE DETAILS Office Use Only Residential X Indoor Basement Solar Commerical Outdoor 1st Floor Pool X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED P1 Exit Fixtures Sump Pump Other Equipment Intermatic Pool Panel, 220 GFI Pump, Hayward Salt Generator, Waterbond on Pipe, Heater, 1 bonded 120 GFI Light Notes: Pool Inspector Signature: Date: May 23, 2025 S. Devlin-Cert Electrical CompOnce rm(9) OE so # # TOWN OF SOUTHOLD BUILDING DEPT. Comm,��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE.& CHIMNEY { ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. [ ] FIRE RESISTANT-PENETRATION [ ] ELECTRICAL (ROUGH). ELECTRICAL (FINAL) [ ] .CODE VIOLATION ] PRE C/O [ ]. RENTAL REMARKS: Teal) Ad 77 DATE` INSPECTOR oe souryO� # . # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [F.FINAL�Mt,,,.- GH PLBG. FOUNDATION 2ND [ LATION/CAULKING FRAMING /STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: • r � G 4 • DATE $ l o INSPECTOR �i sue. 1 e� - �� ....; �� I ;;�� � ,� ,' 'I N X - r. s Wiz. :. �' .. � _ - - - '%y' �� ��:Y ��� lam. it 1 i i i A r . � y �� �� �O�C � � ;� \� �\ - «� .a 2 [ ���ƒ � � � � � � \ . . :. z » � ° ,�£ : � : ~ . �. . y� > / w�_: � -»� . . . ,�� } \ § . . � \� k., i FIELD INSPECTION REPORT DATE COMMENTS ►o hn FOUNDATION 1ST ------------------------------------ ` r� FOUNDATION (2ND) Al z 4—, o cn y ROUGH FRAMING& } PLUMBING 00 N GV ° r r INSULATION PER N.Y. STATE ENERGY CODE Q �� Y1✓M 1�0 FINAL ADDITIONAL COMMENTS c� ! i /11 ` 5 11 V017 otuloo - � o Z_: rn � Xv so z x x d b H 1 I �o�4SUFFQtA�o� TOWN OF SOUTHOLD-BUILDING DEPARTMENT '' y= Town Hall Annex 54375 Main Road P.O. Box 1179 Southold,NY 11971-0959 z Telephone(631)765-1802 Fax(631)765-9502 Iittps://www.sotitholdtownny.gov Date Received APPLICATION FOR BUILDING PERMIT ry§ For Office Use Only � PERMIT NO. 6 Building Inspector: NOV 5 2024 r Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: Y 1 ar. �- SaA c so a SCTM��y# ,OO-pg .Qp-OaO.CEO Project Address: L1C)Z NCLSSAO Pd',Na RoaA (L Q ue N1)Q ll°t35 Email:#: 6b1- a1100 con, Mailing Address: 356 S . v2 r ►�. `'o G•t IJOt� tom. J '( CONTACT PERSON: Name: Mailing Address: a$y qs m��� i�o�,,� C k ei.,o u-e N Phone#: (9� )_ `�'1`f- Alba'; Email: r� a.rc�; �ec��o��oro�;at Nei -DESIGN PROFESSIONAL INFORMATION: Name: MrY -IL Mailing Address: a$LE a 5 (Y1 ', R o�� C J 8,- ue ti`f I(q3j Phone#: (�'��- 3�`(- y ba �} Email: tY�kSG►-c�.; �ec� 0 Qpbv►ilii ae , �JJ Y- - CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Mother lf(/ �Q�1� $ Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? es ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to d this property? ❑Yes;Vo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided'by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance.of a Building Permit pursuant to the Building zone Ordinance'of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction'of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors,on premises and in building(s)for necessary inspections.False statements made herein are punishable as a class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print namel_• , , X—Uthorized Agent ❑Owner Signature of Applicant: Date: (t, f ( CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State-of New York SS, No.01 BU6185050 COUNTY Qualified In Suffolk County Commission Expires April 14,2 ' Z being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he.is the Ar_c/,4;-z� (Contractor,Ag nt,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ' `�D V cf 20 4&y\ �' Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, Gi residing at S • S;1verPG�.-,��4� soCs _do hereby authorize z to apply on my behalf to the To, .n of: hold Building Department for approval as described herein. Owne s Sign,;fu a Date l� `: a k 1 IrAG-c scr) Print Owner's Name 2 U� " Lb BUILDING DEPARTMENT-Electrical inspectorAY 3 2025 TOWN OF SOUTHOLD 80din Department Town Hall Annex-54375 Main Road -PO BWA41 %Outhord Southold!New York 11971-0959 Telephone(631)765-1802- FAX(631)765-9502 roQ9-rr2s01ut oldtownnv.00v ro seand0southoldtownnv.00v APPLICATION FOR E ECTRiCAL INSPECTION ELECTRICIAN INF RMATION (wt information Required) Date: i3 Company Name: C Electrician's Name: Llcense No.: mr-3 yO21 Elec.ernall: hv*"f!X VA vo. oA-1 Elec. Phone No: 1- � request n small copy of Cettlfl' ® of Compliance Elect'Address.: r SITE INFORMATION (Alt Information Required) Name: sAA cS®/V Address: L) 3 t) C v Cross Street: Phone No.: 91 -- y - 01980 Bldg.Perrwd#: l 5GL 1 small: ga- k, Tax Ma District: 1000 Section: Block: Lot: BRIEF DESCRfPTloN OF WORK, INCLU DE SQUARE FDOTAG '-(Plesse'Pr1ht Clearly): logs 5w tAA j5,66L, tata+ l oc as: Circle All That Apoly: Is job ready for inspection?: YES 4 E],Fkough-In r7 Final Do you need a Temp Certificate?: ' El YES NO Issued On Temp lnformatlon: (Ail informaton required) Service Size]1 Ph[]3 Ph Size: _....A #Meters_Old M®ter# ❑New Service[]Fire Reconnectrl Flood Reconnectj]5ervice ReconnecCUnderground Dverhead #Undo, round:Laterals 1 rj2 H Frame mole Work done!on Servlce? Y N Additional information: PAYMENT DUE WITH APPLICATION d — u u LIZ M AY 13 2025 BUILDING DEPARTMENT-Eleetrlcal Inspector TOWN OF SOUTHOLD emiwn Town Hal{Annex- 54375 Main Road-PO 8U %Outsold Southol^, ew York 11971-0959 Telephone(631)765-1802- FAX(631)765-95a2 rorxerr southoidtawnnv Q seandgksoutholdtownnv.00� APPLICATION FOR EL9CTRI96L INSPECTION ELECTRICIAN NF TION (Air wormdon Required) Date: r3 Company Dame: AM Electrician`s blame: 4f License No.:. j '' Elea. ernsll: rx 1Rv,",eaS �Z *o• 0A Elec. Phone No: 1 S- request n email copy of C e of Compliance Elea.Address.: JOB SITE INFORMATION (Ali information Required) Name: s A A c SV V 4 6. Address: y' 3 n Cross Street: Phone No.: l - `I&t- 0900 � Sidg.Perm t#: � I S�� Small.. Tax Mac i.strict: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUt7 SQUARE OOTAG (Phase P�rtit C{dsriy}: u',A Foo�ta : Circle All bat Apply. Final Is job ready for Inspection?: YES 0 Rough In El Do you need a Temp Certificate?: ' YES NO lssued On_ Temp Information, (Ali Information required) Service SizeE11 Ph r13 Pig Size'. ___.___ #Meters Old Meter# [].New ServlcC Fire ReccnnectElFiood ReconneaOservice ReconnectC]Underground[{Overhead rd e round is#erais 1 2 H Frame Pole VUcrkdone on S!Mce? Y N onal Information: pA_�nllH�uE wnnTH apPLlc�0 4 PERMIT# Address: Switches Outlets GFI's I Surface Sconces H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pumps/ Exhaust Oven Sump H eate Trnsfmr Smokes DW Generator Salt Gen. i r Carbon -Micro GrbDis Water Bond ; Lights y Heat Pucks ERV HOT TUB SPA � Inst Hot DeHum Transfer Disc 0 Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments REVISIONS: SITE DATA 1. CUT BACK EXISTING FENCE FOR CONSTRUCTION ENTRANCE 18'-0"MAX. C.to C. PROPERTY: 21,499 SF 0.494 ac ESTIMATED AREA OF 4,000 SF GROUND DISTURBANCE: 2. VERIFY EXISTING SEPTIC SYSTEM LOCATION, PRIOR TO CONSTRUCTION, " GRADE �- AS NOTED FROM REALTOR. FLAG AREA, WHERE LOCATED. NON CONFORMING LOT: R-40 � W � 3. EXISTING ROCK, WALL TO BE REMOVED AND KEPT TO SIDE DURING j EXISTING: AREA LOT COVERAGE: CONSTRUCTION. ROCKS TO BE RE-PURPOSED AS SHOWN ON THE PLAN. �j 6 MIN. HOUSE: 1,716 SF ADDITION ROCKS TO BE SIMILAR TO EXISTING AND APPROVED BY OWNERS. DECK: 578SF PORCH: 200 SF 4. GRADE TO BE LEVEL FROM NEW ROCKWALL LOCATION TO EXISTING PATIO. "0� ` HOT TUB 63.25E OUTDOOR SHOWER: 32.0 SF 5. FENCING TO BE: REPAIRED / REPLACED (REVIEW WITH OWNERS). PERSPECTIVE VIEW TOTAL: 258'9.2 SF 12.1% 0 6. NEW POOL FENCING AND GATES TO MEET THE REQUIRED SPACING, HEIGHT, OUTSWING / SELF LATCH AND LOCKING, etc. REVIEW OPTIONS AND SITE FENCE MINIMUM 2 x 2 PROPOSED: AREA LOT COVERAGE: LAYOUT WITH OWNERS. FENCE POST POOL: 648 SF 3.0 7. SILT FENCING TO BE INSTALLED AND MAINTAINED THROUGHOUT THE WOVEN WIRE FENCE COMBINED TOTAL: 3389.2 SF 15.1 % DURATION OF THE PROJECT. (6 x 6 - 10 / 10 WWF) z METES AND BOUNDS: SURVEYOR: SECCAFICO LAND SURVEYING,PC -08-20 8. GENERAL CONTRACTOR TO REVIEW LIMITS OF CLEARING WITH OWNERS FILTER CLOTH SCTD: AUGUST � DATE SURVEYED: AUGUST 15,2024 PRIOR TO COMMENCEMENT OF WORK. s N CO�JE ELEVATIONS REFRENCE: NAVD 1988 0 1 EMBED FILTER CLOTH GRADE V MIN. 6' INTO GROUND Z AP PR VED AS NOTED c �•(1 o e.P 41 Ov FEE ��� 8Y WM BUILDING DEPARTME TAT 0 G NOTE: 631765-1802 8AM TO 4PM FOR THE A"'+ MAXIMUM DRAINAGE AREA FOLLOWING INSPECTIONS: 0 1( �tc 1/2 ACRE / 100 LINEAR FEET 1. FOUNDATION-TU♦10REQUIRED [�FOR POURED CONCRETE a ` l 2. ROUGH FRAMING&PLUMBING V SECTION DETAIL 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE I I I SILT FENCE DETAILS REQUIREMENTS OF THE CODES OF NEW N 7 8 O 3 6 2 0 E 200 * 00 PORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS SILT FENCE Z b 8 ► - 60 , ,d; COMi 'F`;Xt wTM fll CODES 07 NZW FORK:STATE t TOWN CODES AC UNITS — ��S REQUIRED AND CONDITIONS OF W PROPOSED PATIO ON GRADE ,ry^ ,• A ®� E:i O �u* JtUtrnrd��LG: t� e 1tfn O Pr' Loj POOL`• • p. O 0 Z / / -'- �� EQUIP. � --- �, �E �v '� � DRY I \ � ��._ _ _ _ PRO OSED 16 X36' Q WELL VINYL PO L\ , , BLOCK � z x CONCRET PATIO o � OZ 'WASHOUT 't U III / I 74 OCCUPANCY OR i •8 USE IS UNLAWFUL lov SOIL SEPTIC �YITHOUT CERTIFICA HOT / LOCATION VENT PORCH EX ROCKWALLTO B DISASSEMBLED CONC. TUB 1 STORY �F OCCUPANCY NEW WALL AND FENCING BY OTHERS u WALK HOUSE SLATE WALK DETAIN STORM WATER RUNOFF x // PURSUANT TO CHAPTER 236 m N C, OF THE TOWN CODE. O c� m o O rn Ck o '� °¢' CL SILT FENCE � � / BLOCK CURB CONC. WALL e CU V ELECTRICAL. � Eb .5 ° 3 � WOOD INSPECTION REQUIRED � DECK / ASPHALT 00 GARAGE UNDER �RIV IN"iN1720I TELL 0 w E: CLOSE POOL TO'CODE>. / ASPHALT DRIVEWAY AY � _;�POIvCOMPLETION , 'BEFORE I'WATER'.'_. CL cn CO C. WALL , 84.8 O u LLI CONC. WALK BLOCK CURB oo — N BLOCK CURB 06 C) N x � R � S 78036 '20" W 230e00' O IV TIM'" N PROPOSED SITE PLAN A DRAWN: MH/MS SJ OS .» E� ` s SCALE• SCALE: 1" = lb'-0" w Y JOB#: 11/13/2024 i . � SHEET NUMBER: s ps�p REVISIONS: / \ 1-1/2"TO WASTE-* — HAIR & LINT 1 1 STRAINER I I FILTER PUMP AUTO SKIMMER � � I 8'dia., 4'deep DRYWELL / \ / PENTAIR AUTOMATION, LED LIGHTS, \ \ FILTRATION, 140k ELECTRIC HEATER POOL � — — —BACK TO POOL OPTIONAL DUAL MAIN DRAIN WITH HYDROSTATIC VALVE AND COLLECTOR TUBE IN GRAVEL BASE FILTER AND PUMP LOCATION PER OWNER , PIPING SCHEMATIC xi NOT TO SCALE SKIMMER SKIMME \ SKIMMER t I a I I I I 10" Q I I W I I I I I VINYL LINER O TRACK o a DUAL DRAINSI I I ° O w/STRAINER \ 3' I D D o SHALLOW END I (NGB SAFETY A (MIN.) ( I <1 3'-6" DEEP I APPROVED DRAINS)I I VINYL LINER po ° a D #3 REBAR DEEP END I I ° (3) HORIZONTAL 6'-0" DEEP I I 1 G 3'-6° PADDI / ♦ D D 36-0 ( - / - I °° ° a ° 3500 PSI ♦ ° ° CONCRETE / I � RETURN RETURN__, - / RETURN ( C) I O � ° WALL DETAIL NOT TO SCALE o — — — — — — — — — — --- — — — — — — — — — — — — — — — — — — — — — Qo M O t U PLAN I E POOL NOTES: 1. POOL AND PROPERTY TO CONFORM TO CURRENT STATE AND LOCAL CODE, NOT TO SCALE ENERGY CONSERVATION ( R403.10) AND ELECTRICAL CODES. cri N G p 2. POOL SHALL CONFORM TO ANSI/NSPI STANDARDS R326.3.1 Sn, cu Y o m °� 3. SECTION R326.7 POOL ALARMS TO BE INSTALLED AS REQUIRED BY CODE. 4. INSTALL TEMPOARY PERIMETER BARRIERS AROUND CONSTRUCTION AREA w -UI DURING CONSTRUCTION. FINAL FENCING BARRIER PER R326.5. ALL GATE ACCESS o v TO BE SELF-CLOSING AND SELF LATCHING/LOCKING PER CODE. 5. POOL AND HOT TUBS TO COMPLY WITH R403.10.1 (HEATERS); R403.10.2 (TIMERS); R403.10.3 (COVER) U It �- in 6. #3 REBAR TO BE INSTALLED, 3" IN, FROM BACK FILL. N i~ a (GRADE) _ 7. SOIL CONDITIONS AND SITE MANAGEMENT TO BE RESPONSIBILITY OF 10"CONCRETE WALL CONTRACTOR. PROVIDE SOIL TEST IN POOR SOIL CONDITIONS. (SEE DETAIL) 3-6 8. SEE SITE PLAN (BY CONTRACTOR) FOR POOL LOCATION. SETBACKS, VARIANCES, cm Ll 6-0 AND OTHER STATE AND LOCAL REQUIREMENTS TO BE VERIFIED PRIOR TO CONSTRUCTION. U 9. DRAIN COVERS TO MEET CODE REQUIREMENTS (VIF). v7 3 10. POOL PATIO SURFACE TO SLOPE AWAY FROM POOL 1/4":1'-0" AND AWAY FROM HOUSE IF CONNECTED. PROVIDE ADDITIONAL DRAINAGE IF NECESSARY. N min. 3" COMPACTED 11. INSTALL CLEAN BACKFILL, FREE OF CLAY AND ORGANIC MATTER. COMPACT SAND UNDISTURBED SOIL AS REQUIRED PRIOR TO PATIO INSTALLATION. EARTH (TYP) 12. SUCTION OUTLETS PER ANSI /AP -SP 7. VERIFY IN FIELD PRIOR TO CONSTRUCTION. � 13. SURCHARGE NOT PERMITTED WITHIN 4' FROM SHALLOW AND 6' FROM DEEP ENDS. d 14. DIVING BOARD TO BE DETERMINED BY INSTALLER AND OWNER. 15. POOL EQUIPMENT LOCATION TO BE DETERMINED IN FIELD (MAINTAIN MINIMUM 36-0 SETBACKS AS REQUIRED). �" �►. SIDE SECTION � • �� � DRAWN: MH/MS I,s4',, ' �„ � SCALE: " JOB#: NOT TO SCALE v 11/13/2024 SHEET NUMBER: