Loading...
HomeMy WebLinkAbout51852-Z '�°f s°uryo!° Town of Southold * * P.O. Box 1179 �04 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46474 Date: 09/08/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 500 Broadwaters Rd Cutchogue, NY 11935 Sec/Block/Lot: 104.4 0-5 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/14/2025 Pursuant to which Building Permit No. 51852 and dated: 04/21/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for. Maintain clearances to combustibles as required by code. / The certificate is issued to: 500 Broadwaters LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:. ELECTRICAL CERTIFICATE: 51852 5/2/2025 PLUMBERS CERTIFICATION: (Autluzed Signature ofSO&Tyo�o TOWN OF SOUTHOLD BUILDING DEPARTMENT • 4 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51852 Date: 04/21/2025 Permission is hereby granted to: 500 Broadwaters LLC 138-32 227th St Laurelton, NY 11413 To: install generator as applied for. Generator must have 10'minimum setbacks from all lot lines. Premises Located at: 500 Broadwaters Rd, Cutchogue, NY 11935 SCTM# 104.-10-5 Pursuant to application dated 03/14/2025 and approved by the Building Inspector. To expire on 04/21/2027. Contractors: Required Inspections: Fees: GENERATOR $125.00 ELECTRIC -Residential $100.Ob CO-RESIDENTIAL $100.00 Total S325.00 --------------------- Building Inspector pF SO(/Tyo �o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Southold,NY 11971-0959 �OIyCOU ,� �. BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE . SITE LOCATION Issued To: Mariland LLC Address: 500 Broadwaters Rd City: Cutchogue St: NY Zip: 11935 Building Permit#: 51852 section: 104 Block: 10 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: G&S Electric License No: 31568ME SITE DETAILS Office Use Only Indoor 1✓ Basement r Service Solar r Outdoor 1st Floor F Pool r Spa Renovation r 2nd Floor r Hot Tub r Generator 170 Survey FV Attic r Garage Battery Storage r INVENTORY Service 1 ph (! Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph 1— Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 300A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 32kW Generac Generator w/ 300A Whole House Transfer Switch Notes: Generator Inspector Signature: X Date: May 2, 2025 Sean Devlin Electrical Inspector sean.deviina_town.southold.ny.us 50013roadwatersGenerator o�,oE souryOlo P &52" - - I-- - TOWN OF SO ��-_ � } `� UTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ].. INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE'&:CHIMNEY [ ]- FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:V4C4 n �h tA rr) uOA J��j CIA Y c,�e 1—a. C DATE INSPECTOR �aoe souryo TOWN OF SOUTHOLDD-BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING]STRAPPING [vFINAL pay" 9 ] FIREPLACE & CHIMNEY [ .] FIRE SAFETY�INSPECTION [ ] FIRE RESISTANT CONSTRUCTION - [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: d��W Cbe,17 �66k 17.ec.ae�. 7 L� MA0*4?! K DATE �-ol S = INSPECTOR � ° � �\`� � ' . � ` ` � � \ . . � » . � \ ° \ � 2 � ' ƒ � � \ � � \ ; \\ � ©\�: § �� � , � , � � � ' 7 \ � � � �y � f \ : � © � y � f : ° �� ; \» > : . k � \ � /\ » . | � . < w � \ \ > / � ■_ y � \ , \� � u . > , y. \ . . � : y�� . � � m \ � \�._.� � . . & � . \ � . . , . � . �� . : . . � � � � � I � » ` � . . � . . \ � ) , � � � � | . . . # . . . z � , « ` � � , » ! f �w� . � � � ` � � �� � � � � � \\ < \ , � \d:�� \ 2. � . � �` . � ( ° z : . . « . y � : . . ». . .� - � . « ., y22 : , © . , � � . : a . ~° ��� . � � % � .�� : �\ � . .: . . t� >� � \ � .�.�.:� - / � . . r � . . , � : : � \± ° } x � - � � . y �. TniE.Irutiuro Is q.IPP*d with B STANDBY GENERATOR S STEM CEItB.tructuro MI fqulp"d'un SYSTFME DE GENERATRICE DE 4ECOUPS ML FAM tatr ,cture ntd Bquipede con un SISTEMA GENERA DO.DE RESERVA �,ryUEI DE CARIPE: LOCATIGH: IidDi PE DURANT EMPLACEYEHT: TPO DE COMBUBTIBLE: UBCi1C1GN: Q N.NnI G.. �Dlgw IkrMi ,� 4•.N.NroI pWN ONON OOUN1 LP Gam MaH DrY G .PL Soon 0� G..GLP 9r 6H DO NOT REMOVE THIS DECAL NO RETIRAR LA PEGATINA 4 �pp v-v a dPf' ��r 'li•l 1 � ..., � J�' td lt.S ���Fj' k. - g,!,f: wni, ,:. GENERAC +d EMERGENCY DISCONNECT' SERVICE �...q.�.. DISCONNECT -_ _ � i. •ter.:y. IT ZY 74 Ilk qk a _ 1 �... yam^ +�ir�� r - 1. _+...`�I d:- ,� ►' �f �l} ►. .4{i�r w� � '?SAC* y �`' .. , r '� y�,t't�' \ +�\`'� • � µ.me y � � �SufF�r�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)76571802 Fax(631) 765-9502 hqps://vAvw.southoldtomm.gov Date Received APPLICATION FOR BUILDING PERMIT, DE DYE For Office Use Only A ZOZS PERMIT NO. f� Building Inspector: MAR �+ Applications and forms must be filled out in their entirety;Incomplete Building Department applications will not be a"ccepted Wherethe Applicant�s'not the owner,an Town of Southold Owner's Authorization form(Page 21 shall be completed; Date:2/7/2025 i3OWNER(S)OFkPROPERTY f Name Terry Ann Burrell SCTM#1000- 10V l(-) Project Address:500 Broadwater Rd CutchoguMe NY 11935 Phone#: 1-4 _ Ema11Jffr aA icould.corn Mailing Address: P0rGoq '^-)c;& rz Q��_. 0. , PERSON v Name:Jesse Gaffga _ Mailing�Address:3350 Grand AveMattituck,_NY 11952 Phone#:631-375-2737 Email: Jgaffg,a@jtechss,COm �_ W DESIGN PROFESSIONAW!NFORMATIOIV Name: Mailing Address: Phone#: Email: e XON TRACT OR'INFORMATION Name:J-Tech Mailing Addres5:3350Grand Avey _ -Mattituck, NY 11952 Phone#:631-298-4238 Email•' aff a techss.com DESCRIPTION OE PROPOSED CONSTRUCTION`° �` fl n El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [i10ther32KW Generac Generator $20000.00 Will the lot be re-graded? ❑Yes ONo Will excess fill be removed from premises? ❑Yes BNo • 1 o�OS11FFOl, �oG BUILDING DEPARTMENT-Electrical Inspector ,may. y TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 o ! Southold, New York 11971-0959 Telephone (631) 765-1802- FAX (631) 765-9502 iamesh(aDsoutholdtownny.gov— seand(aDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: G&S Electric Electrician's Name: Rob Guarreillo License No.: 31568-ME Elec. email: Jgaffga@jtechss.com Elec. Phone No: 631-375-2737 []I request an email copy of Certificate of Compliance Elec. Address.: 250 Budd Ponds, Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Terry-Ann Burrell Address: 500 Broadwater Rd Cutchogue, NY 11935 Cross Street: Wunneweta Rd Phone No.: 631-375-2737 Bldg.Permit#: email:igaffga@jtechss.com Tax Map District: 1000 Section: 104 Block: 10 Lot: 5 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 32KW Generac.Generator Square Footage: Circle All That Apply: Is job ready for inspection?: YES F✓ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES r&-/�NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: - A #Meters Old Meter# ❑New ServiceE]Fire ReconnectE]Flood ReconnectE]Service Reconnect[]Underground[]Overhead # Underground Laterals 0 1 2 0 H Frame Pole Work done on Service? n Y nN Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT-Electrical Inspector Gym TOWN OF SOUTHOLD C* � x Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(a)southoldtownny.gov - seand a southoldtownny.c ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: G&s Electric Electrician's Name: Rob Guarreillo License No.: 31568-ME Elec. email: Jgaffga@jtechss.com Elec. Phone No: 631-375-2737 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 250 Budd Ponds, Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Terry-Ann Burrell Address: 500 Broadwater Rd -Cutchogue, NY 11935 Cross Street: Wunneweta Rd Phone No.: 631-375-2737 Bldg.Permit#: 1 email:Jgaffga@jtechss.com Tax Map District: 1000 Section: 104 Block: 10 Lot: 5 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install 32KW Generac Generator Square Footage: Circle All That Apply: Is job ready for inspection?: ® YES 2] NO ®Rough In ® Final Do you need a Temp Certificate?: F-1 YES FV-� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service Fire ReconnectO Flood ReconnectOService ReconnectOUnderground Doverhead # Underground Laterals M 1 2 H Frame Pole Work done on Service? Y MN Additional Information:. PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water BondLights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Flood Blower Service Amps Have Used Sub Amps Have Used Comments S.C.T.M.NO. DISTRICT: 1000 SECTION:104 BLOCK: 10 LOT(S)-5 BROADWATEER COVE LINE S 81'OY48'E 71.92' _ 0 TIML W AND NWMDAL wvmi .. BOWNBARY AS `^ DaWAM Ur Aua a e °m Nw is.,oet\ AMaow.� ZONE AM r) / LOT 184^ ttt511 / 0.2i pNNCE X LOT 185 W'-' x x fsa LOT 183 .... ;hN :,tcrTi: 1H.9 , 'i•`r pcc4�t,r� 8. nft rooB B6K 20.2 2e'c 1.4T P v4•)i"f'"r ti.i^tWht 18.4' RE My- 20.1'. SANITARY LOCATION RfL POINT'A' P01NT'B. Oa"0VM WA ssmw I�, FUJI� as I D.P. 9 o FLU rnilo ' LP1 2 5H o LP2 e o ep LORAN 13k�91 t"i^.:I I I z 0 01eywyf'. Y I I 14.7' UPDATE 11-20-24 �10, 2'r Y a M.1. REVISE)SANRARY LOCATION 07-20-24 02' RENSED 05-31-24 O.PO 4Bg FINAL SURVEY w—u-24 �i 1?0 FOUNDATION LOC.01-08-24 REVISED 05-30-23 FIELD OLSPECT/UPDATED 03-22-23 _ THE WATER SUPPLY, WELLS DRYWELLS AND CESSPOOL FEMA MAP#36103CO164H AND OR o�A OBTAINED FROM 07HERSO)W ARE FROM FIELD �VA710NS AREA: 32,105 S.F. or 0.74 ACRES ELEVATION DATUM: NAVD88 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A WOLA77ON OF SECTION 7209 OF THE NEW PORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONWDRED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 7IILE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT 7RANSFERA9LE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT 7HE PROPERTY LINES OR TO GUIDE THE RECRON OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: LOT 184 of NET, CERTIFIED TO: TERRY—MN BURRELL MARILAND LLC; MAP OF-AMENDED MAP A OF NASSAU POINT I0 FIRST AMERICAN TITLE INSURANCE COMPANY; Fi ED:AUG 16, 1922 No. 156 (0�2�'�' r° � MORGAN S MLEY PRIVATE BANK, NATIONAL ASSOCIATION; SITUATED AT:CUTCHOUGE Y 0 O TOWN OF.-SOUTHOLD 0 KENNETH M WOYCHUH LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK gym ososs2 J2a Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 N PHONE(881)298-1588 FAX(881)298-1588 FILE 9221-198 SOALE:1"-40' DATE: OCT. 15, 2021 N.Y.S USO NO. 050882 mal W the Now&or Robert r.Henn.r mesh X Tgehvt' Al APPROVED AS NOTED DA B.P.0 18 aZ . ,7 , OCCUPANCY OR NOTIFY BUILDING DEPARTMENT AT mi 7wiso2 mm TO 4PM FOR THE USE IS UNLAWFUL FOLLOWING INSPECTIONS: WITHOUT CERT-IFICA- 1. FOUNDATION-TWO REOUIRED FOR POURED CONCRETE OF OCCUPANCY 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF .NEW YORK STATE&TOWN CODES ELECTRICAL AS REQUIRED AND NDITIONS OF INSPECTION REQUIRED TOWNZBA TOWNPLAN oem : TOWN NSTEES Y--�DEC SOUiN010t�C ' �D A GENERAC® o XG Protector° Series Protector® Series Standby Generators _ Liquid-Cooled Gaseous Engine STANDARD FEATURES STANDBY POWER RATING y Model XG03245—32 kW,60 Hz Emergency Standby Power Generator • Power ZoneO 410 Controller,NFPA 110 System Control Capable Model XG04045-40 kW,60 Hz Emergency Standby Power Generator • Padlockable Control Panel Cover with UV Protection Model XG04845—48 kW,60 Hz Emergency Standby Power Generator • Cellular Connectivity for Mobile Link and Fleets • Quiet Operation • Corrosion Resistant Aluminum Enclosure,Electro-Galvanized Baseframe ( �- Components,and Stainless Steel Exhaust Systemft • 5 Year/2,000 Hour Limited Warranty "- , • High Motor-Starting&Surge Capacity • ±1%Digital Voltage Regulation • <5%Total Harmonic Distortion Power Quality ..� .` • Fuel Efficiency k ti • Controller-Selectable Fuel Type-Propane or Natural Gas .�,�.�° i? i • 1-Phase or Configurable 3-Phase Voltage Output Models • Single-Side Regular Maintenance Access ' • EPA Emissions CertifiedGFN • CA&MA Emissions Compliant 40&48 kW Models R • UL 2200 Listed F qC kR. • 145 mph(233 km/h)Wind Speed Rating2 1-Cellular service for the US,Canada,and other supported countries using the *. ro r Generac Generator Connectivity Accessory,Cellular(GGCAC) 2-Requires correctly prepared concrete pad and anchoring system. OPTIONAL FIELD-INSTALLABLE FEATURES Available as field-installable kits. Product may vary from above image depending on model. • 3-Phase Voltage Configuration Cartridge(VCC) • 3-Phase Circuit Breakers(1-Phase Generators Include the Circuit Breaker) • Generator Ready-Status Indicator • Push-Button Emergency Stop ON �C • NFPA 110 System Control&Remote Annunciation c �s( lffir-FED.Mobile Link. • Cold Weather Operation Heaters • Level 2 Sound Reduction 0 • Extreme High Wind Resistance2 'mod • Provisions for Rooftop and Elevated Mounting • Baseframe Block-off • Engine Fluid Containment EPA Emissions Certified • Seismic Anchoring CA&MA Emissions Compliant 40&48 kW Models FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION.This GENERAC'S success in'IMPROVING POWER BY DESIGN."But it doesn't stop state-of-the-art power maximizing regulation system is standard on all Generac there.Total commitment to component testing,reliability testing,environmental models. It provides optimized FAST RESPONSE to changing load conditions testing, destruction and life testing, plus testing to applicable CSA, NEMA, and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque- EGSA,and other standards,allows you to choose GENERAC POWER SYSTEMS matching the surge loads to the engine.Digital voltage regulation at-1%. with the confidence that these systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive service O MOBILE LINK®CONNECTIVITY:Standard cellular connectivity included with network provides parts and service know-how for the entire unit, from the every XG generator,Mobile Link allows users to monitor generator status from engine to the smallest electronic component. anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts.Users O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous can connect an account to an authorized service dealer for fast,friendly,and with GENERAC POWER SYSTEMS. One reason for this confidence is the proactive service. With Mobile Link, users are taken care of before the next GENERAC product line is offered with its own transfer systems and controls for power outage. total system compatibility. O TRUE POWERTM ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power.This allows confident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC systems. GENERAC® 0 GENERATOR SPECIFICATIONS GENERATOR OUTPUT PROPANE XG03245 XG04045 XG04845 Voltage Power(kW) Current(A) Power(kW) Current(A) Power(kW) Current(A) 120/240 V 1—Phase 32 133 40 167 48 200 208/120 V 3—Phase 32 111 40 139 48 167 240/120 V 3—Phase - 32 96 40 120 48 144 480/277 V 3—Phase 32 48 40 60 48 72 NATURAL GAS XG03245 XG04045 XG04845 Voltage Power(kW) Current(A) Power(kW) Current(A) Power(kW) Current(A) 20/240 V 1-Phase 32 133 40 167 48 200 208/120 V 3-Phase 32 111 40 139 48 167 240/120 V 3-Phase 32 96 40 120 48 144 480/277 V 3-Phase 32 48 40 60 48 72 Emergency Standby Power(ESP)Rating:Standby ratings apply to installations served by a reliable utility source.The ESP rating is applicable to varying loads for the duration of a power outage.The average power output over 24 hours shall not exceed 70%of the ESP rating. ALTERNATOR SYSTEM G03245 XG04045 XG04845 -Phase 120/240 V Only 120/240 V Only 120/240 V Only Voltage Output 208/120 V;Configurable for 240/ 208/120 V;Configurable for 240/120 208/120 V;Configurable for 240/ 3-Phase 120 or 480/277 V with Optional VCC or 480/277 V with Optional VCC 120 or 480/277 V with Optional VCC 1-Phase 150 200 200 Circuit Breaker(CB) Size(A) 3-Phase Not Included;Optional,Field- Not Included;Optional,Field- Not Included;Optional,Field- Installable Kit Installable Kit Installable Kit Alternator Type Synchronous Rotor Insulation Class F Stator Insulation Class H Telephone Interference Factor(TIF) <50 Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct Total Harmonic Distortion <5% VOLTAGE REGULATION Type Digital Sensing All Phases Regulation ±1% ! 1: e GENERAC® GENERATOR SPECIFICATIONS 0 SURGE CAPACITY Surge Amps at<0.4 XG03 XG04045 XG04845 Power Factor 15%Voltage Dip(A) 30%Voltage Dip(A) 15%Voltage Dip(A) 30%Voltage Dip(A) 15%Voltage Dip(A) 30%Voltage Dip(A) 120/240 V 1-Phase 107 204 117 267 — — • 208/120 V 3-Phase 111 167 139 215 240/120 V 3-Phase 91 140 114 150 — — 480/277 V 3-Phase 55 87 63 102 — — ENGINE SYSTEM XG03245 I XG04045 XG04845 Make Generac Model 4.5 L,Inline 4-Cylinder,Naturally Aspirated Compression Ratio 9.9:1 Lifter Type Hydraulic Oil Pump Type Gear Oil Filter Type Full Flow Spin-on Cartridge Crackcase Capacity(qt(L)) 12(11). Temperature Derate 1.7%per 10 OF above 77 OF(1.5%per 5°C above 25°C) Altitude Derate 3%per 1,000 ft above 600 ft(1%per100 m above 183 m) Exercise Speed(rpm) 1,200 Operating Speed(rpm) 1,800 Exhaust flow at Rated Output(CFM(m3/min)) 187(8.3) 235(6.7) 280(7.9) GOVERNOR Type Electronic Frequency Regulation Isochronous COOLING SYSTEM XG03245 XG04045 XG04845 Coolant 50/50(50%Ethylene Glycol) Coolant System Capacity(US gal(L)) 2.9(11) Water Pump Type Belt Driven Fan Type Belt Driven Electric Fan Quantity 1 3 Maximum Ambient Air Temperature(OF(IC)) 122(50)