Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50725-Z
*OF Soloryo`o Town of Southold * 0 P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46467 Date: 09/03/2025 THIS CERTIFIES that the building _ ALTERATION Location of Property: 2435 Cedar Ln East Marion, NY 11939 Sec/Block/Lot: 37.4-9 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 01/18/2024 Pursuant to which Building Permit No. 50725 and dated: 05/22/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations and repairs, including deck repairs in kind, to existing single-family dwelling as applied for. The certificate is issued to: Barbara Pagano Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50725 08/07/2025 PLUMBERS CERTIFICATION: Ratsey Construction 09/04/2025 or* edOlur e �Su�FotK TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50725 Date: 5/22/2024 Permission is hereby granted to: Pagano, Barbara 2435 Cedar Ln PO BOX 555 East Marion, NY 11939 To: construct alterations and repairs to existing single-family dwelling as applied for-per Trustees approval. At premises located at: 2435 Cedar Ln, East Marion SCTM #473889 Sec/Block/Lot# 37.-4-9 Pursuant to application dated 1/18/2024 and approved by the Building Inspector: To expire on 11/21/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $333.50 CO-ALTERATION TO DWELLING $100.00 Total: $433.50 Building Inspector OF S0UTy0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 IyCOU �� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Barbara Pagano Address: 2435 Cedar Ln City: East Marion St: NY Zip: 11939 Building Permit#: 50725 Section: 37 Block: 4 Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Indoor 1✓. Basement 1✓- Service rV7 Solar r Outdoor r-.7 1st Floor W Pool r Spa r Renovation r 2nd Floor I'VOr Hot Tub r Generator r Survey Mr Attic M Garage Battery Storage r INVENTORY Service 1 ph F Heat Duplec Recpt 37 Ceiling Fixtures 14 Bath Exhaust Fan 3 Service 3 ph r Hot Water 30A GFCI Recpt 2 Wall Fixtures Smoke Detectors 4 Main Panel 200A A/C Condenser 2 Single Recpt Recessed Fixtures 16 CO Detectors Sub Panel A/C Blower 2 Range Recpt 50A Ceiling Fan 5 Combo Smoke/CO 3 Transfer Switch Track Lights 40' Dryer Recpt 30A Emergency Strobe Heat Detectors Disconnect Switches 21 4'LED Exit Fixtures Other Equipment: Hood, Oven, Fridge, DW, W/D, 200A Panel Notes: . Two Story w/ Unfinished Basement Inspector Signature: X Date: August 7, 2025 Sean Devlin Electrical Inspector sean.devlin(pb-town.southold.ny.us 2435CedarLnHouse Town Hall Annex �� •jam Telephone(631)765-1802 54375 Main Road ® P. O. Box 1179 y a Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: �G Building Permit No. ��7 z Owner: (Pl seprint) Plumber: ,� ��" L (Please print) I certify that the solder used in the water supply system contains le han 2/10 of 1% lead. (Plumbers Signature) Sworn to before me this Jr day of (14 0 Kim E.Fuentes Notary Public,State of New York Qualified in Suffolk County LIC.#01 FU4811709 Notary Public, ��VADILCounty Commission Expires April 30,a _ 1 hO�aOF SOUIyo� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 �5 . 1 _NSPECTION 5e-o, � , [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION -2ND [. } -INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [. ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FI ESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)- [ ] CODE VIOLATION . [ ] .PRE C/O [ ] RENTAL . REMARKS: cal t/ kTv DATE . OY INSPECTOR OF SOUIyOIo TOWN OF.SOUTHOLD -BUILDING .DEPT. o �i� 631-765-1802 v> INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ROUGH PLBG. [ . ] F NDATION 2ND [V(INSULATION/CAULKING FRAMING /STRAPPING [ ] .FINAL FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [. ] FIRE-RESISTANT CONSTRUCTION [ '] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 p pIr-f (ZVtA- DATE '?� INSPECTOR o�*pF SOulyOl � o # * ' TOWN OF SOUTHOLD.BUILDING DEPT.. cou ) 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION-2ND. [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [V .FINAL [ ]. FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANTPENETRATION [ ] ELECTRICAL (ROUE [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATIO [ ] PRE C/O [ ] RENTAL REMARKS: �,A41,t C �V, m uk cov+, c'v DATE / INSPECTOR. OF SOUryo�o V 7 25 cal/Jc;; Ll TOWN OF SOUTHOLD BUILDING DEPT. y ou�m� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]" FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:" DATE INSPECTOR ^ '� . .��. : . - ; - � �� - _ � � - y el > � . . '°�RT,.M... �. e� �.a'. ..`v•�- 4 s��. .. � �,�, .-r," L��T . , /' ,� �, �`�I���5 _r'. ,x-� ^_�. . .-�. .,,r } • } f^^ �m f g 17,717 f .. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) -------------------------------------- C FOUNDATION (2ND) rAA 1OW 1NIW►� t/K J -1^ o H ROUGH FRAMING& m PLUMBING H INSULATION PER N.Y. y STATE ENERGY CODE 2s e co P.w zSL a FINAL p ' r ADDITIONAL COMMENTS = Lt 33sa Pfico rcc o nvcA H O z x d b H '"' TOWN OF SOitJ7t'HoL D—BUILDING DEPARTMENT Town ball Annex 54375 Main Read P.0. fox 1179 Southold,NY i 197i-09S9 t a. Telephone 631 765-1802 Fax 631 765-950211tt i:'1'/ys�sr.;t�utlaa�ldtr������� .(yov z A, i IIOC FOR G RMU _ For Office Use Only y PERMIT NO. Building Inspector: JAR 8 . 2024 Applications and forms must be filled out in their entirety.Incomplete -.•. ,; a r..::......... applications wrill not be accepted. Where the Applicant is not the owner,an Owner's Authdxi on fdrrK(page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: aN �.�i;ti ra� SCfM#1000- `� t 1` 6 Project Address: `Z ie� cj�'&L.Y UKI- L 4:(I 4N C1�C Phone# 3 Erriail` Mailing Address:Z� p '� �� G-f eSL.��? .i \\G\414 CONTACT PERSON: Name: Mailing Address: Phone DESIGN PROFESSIONAL WFO RMATION: �1 e Name:' Itdi elra�g address Cv�-c 0yA KYI 1\Ckt\� Email: G :} L e�..=c}#i ,r /�',•I,�Q{� �l� I'� �� \�Y �i1C.���✓\Z�.� `�`�Va Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑few Structure 0-Addition *Alteration ❑Repair 0Demolition Estimate d Cost of ProJ ect: OOther �'—� �• OVO' Will the lot be re graded? ❑Yes o Will excess fill be removed from premises? ❑Yes ❑No 1 PR®0EitfY I' FORilnATION Existing use of property: l 1�Q 1+<Q a emG Intended use of property: Zone or use district in which a isps�is situated: Are there any covenants and restrictions.With:respect tee { i this property? 0YeSX110 IF YES,PROVIDE A COPY. heck x r eliding: The owner/contractor/design professional is responsible for all drainage and storm crater issues as praWded by XC-ter 236 of the Town Code,APPUCOMON 15 HEOEBY WADE to the Building Department for the issuance of a Building Permit pursuant to Me Building Zone Ordinance of the Town of Southold,Suffolk,county,lUew York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable lames,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildingisl for necessary inspections.False statements made herein are punishable as a class A misdemeanor pursuant to Section 210AS of the New York State Penal Lave. 1 o Application Submitted By(print Harris):LQ(f llj0r Cj �Authoriaed Agent2!!t§a"�rroer Signature of Appiican Date: STATE OF NEW YORK) S : COUNTY OFC6, 5��� ) 0Q C�/��being duly sworn, deposes and says that s he is the a lic -nfi. Y ( ) pp a. (Name of individual signing contract)above n9ned, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this- application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be'performed.in the manner set forth in the application file therewith. Sworn before me this �Q :- v day of N tar JENNA KOCKENMEISTER NOTARY PUBLIC,STATE OF NEW YORK NO.01K06402096 ' a ' `NEAUTHORIZATION. QUALIFIED 1N SUFFOLK.COUNTY' W'COMMISSION.EXPIRES DECEMBER 23,20 (Where the applicant is not the owner) i, residing at do hereby authorize to apply-on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 i 1 r Board of Trustees 2 May 15, 2024 i VIII. RESOLUTIONS -ADMINISTRATIVE PERMITS: 1 B44`RB��yNO requests an Administrative Permit to replace the existing 16'x28.10' irregularly shaped seaward side deck with steps to ground in-place; replace . existing 10.8'x17.11' front entry deck in-place with full length stairs to ground; replace existing 8.7'x18.9' masonry patio with new surface in-place; install a 4'x4' enclosed , outdoor shower on patio; along east wall replace existing sliding door with 6.8' tall by 5' wide slider and three windows; along south wall replace one existing window with new; replace west wall entry door with,new 6.8'x3' door. ILocated 2435 Cedac-Lane-:E ist Mario6. SCTM# 1000�_ SktAclvres� (:C::) / 2� David Bergen on behalf of CUTCHOGUE-NEW SUFFOLK PARK DISTRICT, NASSAU G POINT BEACH requests an Administrative Permit to install modular unit children's playground equipment. Located: 9430 Skunk Lane, Cutchogue. SCTM# 1000-104-8- 6.1 3. BONNIE &JAMES NAULT request an Administrative Permit to construct an irregularly shaped approximately 21'x25' at grade flagstone patio with 4"-6" gravel joints (approx. 525sq.ft.); install a pad for a bbq on the new patio; and to install two irregularly shaped flagstone stepper paths, one from side stoop to back patio (approx. 3'x21'), and the second from master bedroom to back patio (approx. Tx55'), with 4' wide landings. Located: 3550 Little Neck Road,'Cutchogue. SCTM# 1000-103-9-13.2 exrS�h � S 04. Kate Samuels on behalf of THE PLIMPTON FAMILY, LLC requests in Administrative fal Permit for construction activity within 100' from the landward edge of the wetlands for the construction of a 150sq.ft. addition to existing dwelling with interior and exterior renovation; new deck and porch on seaward side; new entry porch on landward side; new a/c unit on precast slab; new septic system; and new drywells. Located: 12250 New Suffolk Avenue, Cutchogue. SCTM# 1000-116-6-11 til( kYc___� IX. APPLICATIONS FOR EXTENSIONS/TRANSFERS/ADMINISTRATIVE AMENDMENTS: Jim Bodkin on behalf of BARBARA BODKIN requests a One (1) Year Extension to (/ Wetland Permit#10145, as issued on May 18, 2022. Located: 610 Bayview Drive, East Marion. SCTM# 1000-37-5-2 Glenn Goldsmith,President UV so(�,y Town Hall Annex A.Nicholas Krupski,Vice President ®� ®�® Q54375 Route 25 P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly Telephone(631)765-1892 Elizabeth Peeples X3 • aO Fax(631) 765-6641 COUMT`1,� BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Permit No.: 10563A Date of Receipt of Application: April 2, 2024 Applicant: Barbara Pagano SCTM#: 1000-37-4-9 Project Location: 2435 Cedar Lane, East Marion Date of Resolutionlissuance: May 16, 2024 Date of Expiration: May 15, 2027 Reviewed by: Board of Trustees Project Description: Replace the existing 16'x28.10' irregularly shaped seaward side deck with steps to ground in-place; replace existing 10.8'xl7.11, front entry deck in-place with full length stairs to ground; replace existing 8.7'x18.9' masonry patio with new surface in-place; install a 4'x4' enclosed outdoor shower on patio; along east wall replace'existing sliding door with 6.8' tall by 5' wide slider and three windows; along south wall replace one existing window with new; replace west wall entry door with new 6.8'x3' door. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the site plan prepared by Nicholas J. Mazzaferro, P.E., received on April 2, 2024, and stamped approved on May 15, 2024. Special Conditions: None. Inspections: Final Inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is n t a determination from any other agency. Glenn Goldsmith, President Board of Trustees Glenn Goldsmith, President ®f S®� Town Hall Annexa�� ® ®� 54375 Route 25 A. Nicholas Krupski,Vice President P.O. Box 1179 Eric Sepenoski Southold, New York 11971 Liz Gillooly Telephone(631) 765-1892 Elizabeth Peeples Fax(631) 765-6641 MUM, E C EC W E ID BOARD OF TOWN TRUSTEES J SEP 3 2025 TOWN OF SOUTHOLD Building Department CERTIFICATE OF COMPLIANCE "Fown of Southold #2288 C Date: August 29, 2025 THIS CERTIFIES that the replacement of the existing 16'x28 10' irregularly shaped seaward side deck with steps to ground in-place-, replacement of existing 10 8'x17 1 P front entry deck in-place with full length stairs to ground; replacement of existing 8 7'xl8 9' masonry patio with new surface in place installation of a 4'x4' enclosed outdoor shower on patio; replacement of existing sliding door along east wall with 6 8' tall by 5'wide slider and three windows; replacement of one existing window along south wall with new; replacement of west wall entry door with new 6.8'x3' door, At 2435 Cedar Lane, East Marion Suffolk County Tax Map#1000-37-4-9 Conforms to the application for a Trustees Permit heretofore filed in this office Dated April 2, 2024 pursuant to which Trustees Administrative Permit#10563A Dated May 15,2024,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the replacement of the existing 16'x28.10' irregularly shaped seaward side deck with steps to ground in-place; replacement of existing 10.8'x17.11' front entry deck in place with full length stairs to ground,• replacement of existing 8.7'x18.9' masonry patio with new surface in-place; installation of a 4'x4' enclosed outdoor shower on patio; replacement of existing sliding door along east wall with 6 8'tall by 5'wide slider and three windows; replacement of one existing window along south wall with new,• replacement of west wall entry door with new 6.8'x3' door. The certificate is issued to BARBARA A. PAGANO owner of the aforesaid property. 4&n4-X-- _ Authorized Signature y SUfF01Ir BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 V11 • Southold, New York 11971-0959 y�01 �a0�yY Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh -southoldtownny.gov — seandta'�southoldtownny.Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: o c a ,`-u License No.: r�� � Elec. email: Ma enon Elec. Phone No: - 7,C 6a3VEW request an email copy of Certificate of Compliance Elec. Address.: Po JOB SITE INFORMATION (All Information Required) Name: Address: Z �. S Cross Street: Phone No.: ,6J 6 Bldg.Permit#: 4'5-072-5— email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE .(Please Print Clearly): � c '200 L I Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES 1O/Z Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 F2 H Frame M Pole Work done on Service? Y' N Additional Information: ` �-, C: PAYMENT DUE WITH APPLICATION I o *17,q la q? 9 PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis � Waver Bond Lights Heat Pucks ERV HOT TU B/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub , Amps Have Used Comments '-PERMIT# 6-0 -7 2S Address: � �3� � Switches e;-? /W INZ d� Outlets c4; s,b e-W e*4eaiPe0of— S G-Ft"s Sconces H H's I VC Lts Fridge HW � 1_2lec4n, p00L Fans �' Mini Fr. W/D I panel .Puma Exhaust 3 Oven Sump Heater Smokes DW ( Generator r rnsl'mr Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat 4 j i2/-boj)1 W Pucks ERR (9'L, , HOT TUBISPA Inst Hot DeHum Transfer Disc Combo 3 Cooktop Minisplit Blower ood Blower Service Amps Z. Have Used Sub Amps Have Used Comments S Cc�v►� rid ►3 n�a- �s /-bo( JLAL 4 ROOF DRAINAGE CALCULATION: m SURVEY OF PROPERTY _.. ROOF AREA= 1319 S.F. _ 1 (]319 S.F.) `(2"/HOUR)= 224 CUBIC FEET REQUIRED PROVIDE MINIMUM(1) 8'DIAM.X 6' DEEP DRYWELL OR EQUIVALENT. C. LOTS 134 & P/O LOT 133 - MAP OFLOT GARDII`IERIS BAY ESTATES-, SEC `," RESID NCEE: 1,319S.F. ' fi, DECKS: 670S.F. o FILED: SEPT. 23, 1927 - MAP #:275 TOTAL: 1,988 S.F. OR 27.1% SITUATE 1 O EAST MARION TOWN OF SOUTHOLD 4 P/0 LOT 133 SUFFOLK COUNTY, N.Y. 132.00 D off TAX MAP NO.: 1000-0.3700-04400-009000 ° ° G" D" 0.5'N oNUN� m O °" G" P/O LOT 133 tn LOT AREA: 7,336.76 S.F. (0.168 ACRES) o olf DATE SURVEYED: SEPT. 8, 2022 v n < D Q Ut j Ncl O n 1 m ❑4-C-UNIT' .O j/1 g PROPOSED DRYWELL:NOV.29, 2022 _ 3 m T in 36.5 - o o U 1 LOT COVERAGE:DEC.23, 2022 G m ASPHALT 0 � AY W 40.8` � �? `j] W 3.7 o N w D O !�t� o 7.a io 5 STORY 0 20 40 I o O 2 6.3 S 1 . Ry o <' ° m m Feet _ J °°o �R' E w ° LOT 134 m n c� o o W ��<� ro RESIDENCE 1V r U I SCALE: 1 INCH = 20 FEET 0 0° #2435 a p I m II D x a U J fn j' fml m k _ x a < _ r 36.5 PROPOSED m ri 8'0 X 6'DP 0 g 6 r O rTl O CONCRE7 E PATIO 1 J DRYWELL 7JQ o u m r ,Cp m n �O O/L 0.3'S m 1.2'S NC. WAu [mxn Du o0.6 D ' ON Z563052 •O D130.0024WtDE =m r c D2 3 LAND - PRIVATE ° �' E r•0, RIGHT OF WAY LOT 135 F U LEGAL NOTES: 1.COPYRIGHT 2019 AIG LAND SUFYE. '?PLLC.ALL RIGHTS RESERVED N 2.UNAUTHORIZED ALTF_RATION OF,ADC!TIO!J TO THIS SURVEY MAP BEARING A LICENSED LAND SI.IRVEYOR'S SEAL IS A VIOLATION OF SECTION 7209 SUB-DIVISION 2.OF NEB J YORK S I;,'E EDUCATION LAW, AJ C LAND SURVEYING PLLC AND OP BOUNDARY Slll3VFY MAPL91:97H THE SURVEYOR'S EMBOSSED SEAR ARE GENUINE fRUF AND COP.RECf GOR=Ih'S OF THE SURVEYOP.'S ORIGINAL WORK C AND OPINION. J 1.CERTIFICATIONS 0:4 TIi1S BOUp.OARY SURVEY MAP SIGNIFY THAT THE MAP WAS PREPARED IN ACCORDANCE WITH THE CURRENT EXISTING CODE OF PRACTICE FOR LAND SURVEY ADOPTED S EY'HE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS,INC.THE CERTIFICATION IS LIMITED TO PERSONS U LAND S U RY�YI N C & P LAN N I N Cz FOR WHOM THE BOUNDARY SURVFV MAP IS PREPARED.TO THE TITL'e COMPANY.TO THE GOVERNMENTAL AGEL ICY,AND TO THE LENDING INSTITUTION LISTED.ON i'F11:>BOUNOAf7/SUF2VL-Y MAP / I'1ii.CCRIIF I[':aIION:+ViCRdP.IkPc NOTTRA.VSFERL4BLE d• I• RI!_l.Cx-gR<;IIi'1 ORc�;—.qD"PRGVEMEfdTSORENCROACHMENTSARENOTALWAYSKNOWNANDOFTENMUSTBEESTIMATED.IFAN'YUNDERGRCIUND L.J 77 S. COLEMAN ROAD, CENTEREACH, NY 1 1720 nu'ROVln9-:I 'iRI:N 3HOACTq.:LNTS EXIST OR ARE SHOWN.THE IMPROVEMENTS OR ENCROACHMENTS ARE NOT COVERED BVTHISSDUSE O 7 THE OI F6ETSIOR DIMENSIOyS?SHCWN HEREOI-t FROM THE STRUCTURES TO THE PROPERTY LINES ARE FOR.A SPECIFIC PURPOSE AND USE AND THEREFORE O ARt !-:O'1 16Ci ENUEO TO GUIDE THE.REGION OF FENCES.RETAINING WALLS,POOLS.PATIOS PLANTING AREAS,ADDITIONS TO BUILDINGS.AND Al,^OTHER TYPE / N PHONE: 631 .846.9973 8 CON i('RUCTION. B ONLY SURVEYS BEAR ING'IHL n!i1<ERS L-nSiiOSSEU SL-AL SHOULD Bt RELIED UPON SINCE O'TH ER'THAN En160SSEL'}SE:AL COPIES MAY CONTAIN ONS, ND EMAIL: A.�C246@OPTONLINE.NET UNAUTHORIZED AND ER OETECTA�:3 WLE ERE NOT S,DELEPART OF SURVEY VEYU UNLESS HER r 9.PROPERTY CORNER MONUMEN',"i WERE NOT SET AS PART GF THIS SURV'cY UNLESS OTHERWISE NOTED. " I O.ALL MEASUREMENTS REFER TO L'.S.SURVEY FOOT. U� r N.J. MAZZAFERRO P.E . ,�. Chkd.By____,_._____ ®ate of Alv A VIA IM ox sq) (wee 0'Poer)W� �1�� - S i e-497-3396 • EMAIL-maz I n@mm com N. J. MAZZAFERRO, P.E. PO Box 57, Greenport,N.Y. 11944 Phone- 516-457-5596 Consulting Engineer January 8, 2024 Design, Construction, Inspection Town of Southold-Building Department 53095 Main Road Southold NY 11971 �',` r7..7f rN r:4;.! Ll Attn: Amanda Nunemaker s JAN 1 8 ~. Property: Mrs. Barbara Pagano 2024 2435 Cedar Lane, East Marion, N.Y. 11939 District-1000, Section-37, Block-4, Lot-9 Re: Application for Building Permit- Revised Design This is in reference to the building permit application submitted on June 1, 2022 for the noted property. There was a Notice of Disapproval written by the Building Department dated March 28, 2023 (copy attached). The applicant/owners of the property are withdrawing that application. The owners have reconsidered the project and have revised and updated the project scope. The new design drawings and building permit application are attached. The revised project scope includes: 1 - Exterior Work—Remove and Replace in kind Deck Surface Boards. There is no change in the perimeter size or position of the front or rear decks. Repair or Replace any damaged-structural frame as needed for safety. Railings to comply with current Code for safety. There is no change being made to any other exterior element of the building. 2—Windows/Doors—Replace the door and three full depth windows on the east side of the house with new Anderson 400 Series Sliding doors. The existing headers will remain in place, openings to be trimmed for new doors. Replace existing windows on the north (1) and south(1) walls of living room and in the second floor bathroom. The existing headers will remain in place, openings to be trimmed for new windows. Replace the street side entrance door in existing opening. All other doors and windows to remain as is. 3- Interior Work—Renovate existing first floor full bathroom to construct two bathrooms, one full and one a%2 bath(see plan). Refurbish second floor bathroom with new fixtures. Remove existing spiral stair and replace with new regular staircase for safety. Install new door to first floor bedroom. Refurbish kitchen in kind. 0 It is noted that the new work scope is an alteration to the existing conditions. The project does not change any perimeter dimension of the building or deck structures on the property. In addition the roof line remains as is. The existing unconditioned shed, outdoor shower and entry steps remain as they currently structured. To assist with the permitting process the following are attached: 1 —NYSDEC—Letter of Non jurisdiction dated June 27, 1991 for Property noted as Lot 134 Cedar Lane, East Marion,NY. Declared- Construction prior to 9/20/77. 2—Southold Town Board of Trustees—letter dated May 3, 1991 —Request for Deck Wavier Approved. 3 —C of O - Z-20068 dated July 11, 1991 for Addition and Alterations to the Existing Structure:Note -the existing structure maintain this configuration. 4—C of O - Z-20220 dated September 16, 1991 for Wood Deck Addition to Dwelling and to ZBA Conditions Appeal#4044 5 —Board of Appeals - letter dated September 20, 1991 transmitting Board determination. 6 -Board of Appeals—Copy of Action of the Board Memorandum for Appeal Number 4044 dated September 23, 1991.Notation that under the findings of fact the Board identified and confirmed in Paragraph 3: - The dwelling as exists has non-conforming side yards,non-conforming front yard, and a non-conforming rear bulkhead setback. - The dwelling as exists has non-conforming lot coverage at 24%. - The parcel as exists is substandard with 7,336, square feet and a frontage width of 56.0 feet. Based upon this Board's Findings of Fact and the Granting of a Variance the existing conditions at this property have been addressed by the Town and the non-conforming and substandard items have been acknowledged and accepted. These reference documents were provided to identify the prior approvals from the NYSDEC, the Southold Town Trustees and the Southold Town Board of Appeals for the existing conditions on this lot and dwelling. It is the intention of this project to refurbish this dwelling without changing any elements that would modify the previously approved conditions. Thank you for your considerations, �ra MA 9 Nicholas I Mazzaferro, P.E. 5 z O NO 057 ROFESSIOVO, TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,NY NOTICE OF DISAPPROVAL DATE: March 28,2023 TO; Robert Anderson(Pagano) PO Box 2003 Bridgehampton,NY 11939 Please take notice that your application dated June 1,2022; For permit to:reconstruct the existing;front&rear decks and raised patio and to reconstruct the shed addition to living;space to the existing single-family dwelling at: Location of property: 2435 Cedar Lane,East Marion,NY County Tax Map No. 1000—Section 37 Block 4 Lot 9 Is returned herewith and disapproved on the following grounds: The proposed construction,on this nonconforming 7,336.76 sq.ft.lot in the R-40 District,is not permitted pursuant to Article XXIII Section 280-124,which states lots measuring less than 20,000 square feet in total size require a front yard setback of 35 feet,a minimum sideyard setback of 10 feet with a combined side yard setback of 25 feet and maximum lot coverage of 20%. The proposed construction will have a front yard setback of 26.3 feet,a minimum side yard setback of 7 feet with a combined side yard setback of 14 feet and lot coverage at 29.6%. (f . Authorized Signature Note to Applicant:Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC:ZBA, file a FORM NO. 4 TOWN OF SOUTHOLD ' BUILDING DEPARTMENT Office of the Building Inspector Town Hall. Southold, N.Y. CERTIFICATE OF OCCUPANCY No Z-20220 Date SEPTMMER_16, 1991 THIS CERTIFIES that the building ADDITION Location of Property 2435 CEDAR LANE EAST MARIONj N.Y. House No. Street Hamlet County Tax Map No. 1000 Section 37 Block 4 Lot 9 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building hermit heretofore filed in this office dated JULY 2, 1991 pursuant to which Building Permit No. 20143-Z dated SEPTEMBER 16, 1991 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is WOOD DECK ADDITION TO DWELLING AS BUILT& TO ZBA CONDITIONS APPEAL #4044. The certificate is issued to WILLI M, AILEEN & JOHN PARROTT (owners) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N„LA UNDERWRITERS CERTIFICATE NO. H-022028 - MAY 10, 1991 PLUMBERS CERTIFICATION DATED N/A Building Inspector Rev. 1/81 I Z 1 APPEALS BOARD MEMBERS '-a -OLA, SCOTT L.HARRIS {( Gerard P.Goehringer,Chairman Supervisor i Charles Grigoms,Jr. Town Hall,53095 Main Road Serge Doyen,Jr. va James Dinizio,Jr. L%' i �, " P.D.Box 1179 ,,,� ° Southold,New York 11971 .,� Robert A.Villa 1- S. Fax(516)765-1823 Telephone(516)765-1809 Telephone(516)765-1800 BOARD OF APPEALS TOWN O�SOUMOLD C �- ��° SEP 2 31991 ACTION OF THE BOARD _,. ft!OF SOU i Pol 1) Appl. No. 4044. Upon application of WILLIAM, AILEEN AND JOHN PARROTT. Variance to the Zoning Ordinance, Article XXTII, Section 100-239.4B and Article XXIV, Section 100-244B for approval of deck construction at less than 75 feet from the bulkhead and in excess of the 20% lot coverage limitation for all structures. The subject parcel is substandard in size and is located in the R-40 Zone District. Location of Property: 2435 Cedar Lane, East Marion; County Tax Map No. 1000-37-4-9. WHEREAS, a public hearing was held on September 12, 1991., and at said hearing, all those who desired to be heard were heard and their testimony recorded; WHEREAS, the Board has carefully considered all testimony and documentation submitted concerning this application; WHEREAS, Board Members have personally viewed and are familiar with the premises in question, its present zoning, and the surrounding areas; and WHEREAS, the Board made the following findings of fact: 1. By this application, appellant seeks a variance under Article XXIII, Section 100-239.4E for permission to construct an 500 sq. ft. open deck extension 16.2 feet from the rear (easterly end) of the existing dwelling. 2. The premises in question is identified on the Suffolk County Tax Maps as District 1000, Section 37, Block 4, Lot 9 and contains a total lot area of 7,336 sq. ft. 3. The dwelling as exists presently has nonconforming sideyards totaling 29-1./2 feet (7 and 12-1/2) , a nonconforming front yard setback at 24 feet, a nonconforming setback from the bulkhead at 56 feet, and nonconforming lot coverage at 24% (1754 sq. ft. ) . The parcel as exists is substandard with 7,336 sq. ft. in total lot area and a width (frontage) of 56.0 feet. Page, 2 - ZBA Appl. No. 4044 katter of JOHN PARROTT and OTHERS Decision Rendered September 12, 1991 4. Article XXIII, Section 100-239.4B of the Zoning Code requires all buildings and structures located on lots upon which a bulkhead, concrete wall, rip-rap or similar structure exists and which is adjacent to tidal water bodies other than the Long Island Sound to be set back not less than seventy-five (75) feet from the bulkhead. 5. Article XXIV, Section 100-244B limits lotsin a nonconforming status" to a maximum lot coverage for all buildings at 20 percent of the total lot area. The increase of the lot coverage over the existing dwelling is 500 sq. ft. , or 70, for a total of 310. 6. For the record it is noted that similar relief has been granted for other parcels in the area, along Sigsbee Road, etc. 7. in considering this application, the Board finds: (a) the relief requested is substantial in relation to the code requirements although the square footage of construction over that which exists is minimal; (b) the relief requested is the minimum necessary to afford relief; the construction is for an open, unroofed addition without a foundation or basement and without a roof or full enclosure; (9) the relief as requested will not alter the essential character of the neighborhood; (d) the practical difficulties imposed are uniquely related to the property and are not personal; (e) the grant of the relief as requested will not in turn be adverse to the safety, health, welfare, comfort, convenience or order of the town, or be adverse to the neighboring properties; (f) in view of all the above, the interests of justice will be served by granting the relief as requested and conditionally noted below. Accordingly, on motion by Mr. Dinizio, seconded by Mr. Villa, it was RESOLVED, to GRANT a variance for a 500 sq. ft. open deck addition at the rear (east end) of dwelling with a reduced 16.2' setback, for a minimum distance from the bulkhead at 39.5+-feet, SUBJECT TO THE FOLLOWING CONDITIONS: Page 3 - Appl . No. 4044 Matter of JOHN PARROTT and OTHERS Decision Rendered September 12 , 1991 1. The southerly (side) yard shall remain open and free of obstructions (with the exception of the existing flagstone area) . 2. The deck addition remain open and unroofed, as applied. (All roof runoff must be retained on site. ) Vote of the Board: Ayes% Messrs. Goehringer, Dinisio and 'villa. (Members Grigonis and Doyen were absent. ) This resolution was duly adopted. ` f r lk / d �.--- GERARD P. GOEHR �LTNGER, RMAN F F©tkoo TRUSTEES '.'Z� G SUPERVISOR John M.Bredetneyer,III,President Henry P. Smith,Vice President �, ,?� SCOW L.HARRIS Albert J.ftn"ki,Jr. John L.$ednoski,Jr. �Ol � ��� ToWaHau John B.Tuthill 3095 Main Road P.O.Box 1179 Telephone(516)765-1892 BOARD OF TOWN TRUSTEES Southold,New York 11971 Fax(516)765-1823 TOWN OF SOUTHOLD May 3, 1991 John Parrott 18-75 CPL Kennedy St. #1-G Bayside, New York 11360 RE: SCTM #1000-37-4-9 Dear Mr. Parrott: The following action was taken by the Board of Town Trustees during its regular meeting held on May 2, 1991: RESOLVED that the Town Trustees APPROVE the request for a waiver for a deck attached to the dwelling located at Cedar Lane, East Marion. Please return to the Building Department for a determination on the need for any other permits which may be required for this project. Very truly yours, 64 4010M ;?O� W John M. Bredemeyer, III President, Board of Town Trustees JMB:j t cc: Bldg. Dept. CAC File f New York State Uepartment of Environmental Conservation .Building 40--SUNY, Stony Brook, New York 11790-2356 AM So),, L . ?a t'r©'r_' - . -S�>,t- �7119 q 1 1�-"�� GPC.- ��ln� S�• . 1 � DATE. � 11 Y r S i GI t; t�l 1 t 3 6 a Re: /ape)-6! (cA )"g735 U63o� Thomas C.sorting Y ) [0drx 1 -O comatlssioner fiye(41 0- Lot 13q Qaffo�} � Ceder Lary, Dear M�. ea vi m act oh ) N A review has been made of your proposal to: L©�3k rUC'j- ')' tp%6&_e- de,-S7 c s per svrvey b7 fkodt tdc VOLvi Tiny l dotted 7/Fs/7 q SC-1 /0,00 -- 37_ Y -q Based—on---the iave submitted, the New York State Department of Env' onmental Conservation has determined that the parcel �: project is: ` Greater than 300' from inventoried tidal wetlands. Landward of a substantial man--made structure h tI�/ f7 (�' greater than 1001 in length which was constructs prior to 9 20 77. Landward of the 10 ' above mean sea level elevation contour on a gradual, natural slope. Landward of the topographic crest of a bluff, cliff or dune which is greater than 10 ' in elevation above mean sea level. Therefore, no permit is required under the Tidal Wetlands Act (.Article 25 of the Environmental Conservation Law) . Please be advised, however, that no construction, sedimentation or disturbance of any kind may take place seaward of the 101 contour or topographic. crest without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation in this area as a result of your project. Such precautions may include providing adequate work area between the 10 ' contour or topographic crest and the project (i-e_ a IS ' to 201 wide construction area) or erection of a temporary fence, barrier, or hay bale berm. Please note .that any additional work, or modification to the project as described, may require authorigation by- this Department. Please contact this office if such are contemplated. Please be further advised that this letter does* not relieve you of the i responsibility of obtaining any. necessary permits or approvals from other ' agencies.' Vey truly yo s, . v beeR�� er A 16 1 { � Deputy Regional Permit: AdministratorT. - Ct&OUT14OLO...f. r , ll�qw MOV QF Olc JJ Ol i • - r �• = •'•«'� :,, 'S 6�jr� •�SC��'•.n.n..,..�:�=a.1�A?�� _ '. ^-•a`•' '�„�3'�! - R' � a ' ''. ..'• __ t . _' I '"-. .A Vol r As. CX Ail 6% 000' �im Of NE A T MM4 ai IL tie LAND oopf"*M- .�Tp r& as -g,' t k% ZY J4 OT VA owl', w FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No Z-20068 Date JULY ill 1991 THIS CERTIFIES that the building ADDITION & ALTERATION Location of Property, 2435 CEDAR LANE EAST MARION, N.Y. House No. Street Hamlet County Tax Map No. 1000 Section 37 Block 4 Lot 9 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated FEBRUARY 25, 1991 pursuant to which Building Permit No. 19691-Z dated MARCH 5, 1991 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION & ALTERATION TO EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to WILLIAM, AILEEN & JOHN PARROTT (owners) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A UNDERWRITERS CERTIFICATE NO. H-022332 - MAY 29, 1991 PLUMBERS CERTIFICATION DATED N/A J za:�L Building Inspector Rev. 1/81 W ,� SGC3TT t.HARRIS APPEALS HOARD MEMBBRS ��.� aupes'v�or r Gerard P.Goehrnger,Chairman ,`� ; Charles Grigonis,Jr. .; Town Mall,53095 Main Road Serge Doyen,Jr. P.O.Box 1174 James Diaizio,Jr. 15 h r a. ' ,"":` Southold,New York 11971 Robert A.Vilia Fax(516)765-1823 Telephone(516)765-1909 Telephone(516)765-1800 BOARD OF APPEALS TOWN O�SOUTHOLD September 20, 1991 Mr. John Parrott . Creative Retirement Planning Inc. ti , 30 Rockefeller 'Plaza Suite 4336 Sip 231991 s New York, NY 1.011.2 Re: Appl, No. 4044 - Variance for Deck Addition • � .•` f'� }'" Dear Mr. Parrott: Attached please find a copy of the determination recently rendered by the Board of Appeals concerning the above application. Please be sure to return to the Building Department and any ,*other agency for permits or other approvals which are appropriate for this project. A copy of this decision has simultaneously herewith been transmitted to the Building Inspectors for their files and update. Very truly yours, Linda Kowalski Enclosure Copy of Decision to: Southold Town Building Department APPRO El AS NOTED �{ lin 1lDA B.P. >> y^. ►ATE4: ES NEEt3 � FEE �. 1S BY: .zy °� ,C01IfR1 �`` NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: I. FOUNDATION-TWO RED'!my-D FOR POURED CONCRETE 2. ROUGH-FRAMING& PLUrvAB eIG PLUMBER CERTIFI.CAT10&- c,, 3. INSULATION ON LEgDCONfEN:T�B�FOR 4. FINAL-CONSTRUCTION MUST CERTZFICATE�Q'F'0CGupANCY 8E COMPLETE FOR C.O. SOLD -USED,�N,V�j�TER ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW S�R!°L�4'SYSTEM'CANNO- YORK STATE. NOT RESPONSIBLE FOR EXCEED2f1D'QF j, LEAD. DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF MDTO—LD—TNOWNZ—BA-- ELECTRICAL SOU iOtBTOWIMM BOARD INSPECTION REQUIRED SOUTHOLD TOWN TRUSTEES - S001 FOLD HPC SCbl9� . All exterior lighting installed,replaced or shall OCCUPANCY OR repairedto Chapter 1720 rm USE IS UNLAWFUL of the Town Code WITHOUT CERTIFICAT OF OCCUPANCY RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. GENERAL NOTES K04 9 L ME INFORMATION WITHINTHMSETOFCONSTRUCTIONDOCUMENTS IS RELATED TO BASIC DESIGN PER THE[Bq(NYS CODES-2020 AS LISTED BELOW OCCUPANCY CLASstmcA-nDN RESIDENTIAL VITINTAND FRAMING DIFIA115.THEY ARE INTENDED AS A CONSTRUCTION AID,NOTES A SUBSTITUTE ADJ ADJACENT MIN. MINIMUM FOR GENERALLY ACCEPTED GOOD BUILDING PRACTICE AND COMPLIANCE WITH CURRENT NEW YORK :L RIDGE404EAFTERASSEMBUt. OCCUPANTLOAD WA ALUM. ALUMINUM MR MOISTURE RESISTANT STATE BOLDING CODES.THE GENERAL CC;NrTtACTCR IS RESPONSIBLE FOR PROVIDING STANDARD 13/4'X 20 GAUGE STRAP SHALL BE ATTACHED TO EACH PAIR OF RAFTERS IN ACCORDANCE TO APPD. APPROVED Mw MILLWORK CONSTRUCTION DEFAILS AND PROCEDURESTO ENSURE A PROFESSIONALLY FINISHED. TABLE&4-WHEN A COLLAR TIE IS USED IN LIEU OF A RIDGE STRAP THE NUMBER OF 10d COMMON 9RDA BOARD NIC NOTINCONTRACIr STRUCTURALLY SOUND AND A WEATHERPROOF COMPLETED PRODUCT. MAILS REQUIRED IN EACH END OFTHF COLLAR TIE NEED NOT EXCEED THE RECOMMENDED BUILDING HEIGHT 9XWnNG2V*' BRIL BRICK Oc ONCENTS 2. ALLCONSTRUCRON TO CONFORMTO THE DESIGN OF THE2018 IBC AND 2020-NYS SUPPLEMENM NUMBER OF MAILS IN THESTRAP. GOT. BOTTOM 05 OWSWiNG 3. THE GENERAL CONTRACTOR IS RESPONSIBILITY FOR ENSURING THATALL WORK AND CONSTRUCTION 2. RAFTER-TOWALLASSEMBLY.- DESIGN CRITERIA 2020 MYS BUILDING GODEr2017 NEC CIL CENTERLINE OPG. OPENING MEETS CURRENT FEDERAL,STATE.COUNTYAND LOCALCOPES,ORDINANCES AND REGULATIONS,ETC LATERAL FRAMING AND SHEAR WALLCONNECTIONS FOR RAFTER,CEILING 08 WALLTO TOP PLATE CLS CEILING PI. PLATE ED THESE CODES ARE70 BE CONSIDER AS PARTOFTHESPECIFICATIOUS,FOR THIS BUILDING AND SHALL BE IN ACCORDANCETOTAOLF3.3.WHEN A RAF"OR TRUSS DO NOT FALLEN UNEWITH CONSTRUCTION TYPE TYPE V PER SECTION CO L CO PLUMEL. PLUMBINGG SHOULD BE ADHERED TO EVEN IF IN VARIANCE WITH TNE PEAK STEMS BELOW,RAFTERS OR TRUSSES SHALL BE ATTACHEDTO THE WALL top PLATE AND THE NI% CO TOP P CONCRETE LYWO. PLYWOOD 4. DIMENSIONS SNALITAKEPRECEDENTOVENSCALED DRAWINGS.(DONOTSCALE DRAWN") WALLTOPPLATESHALLBE TO THE WALLSTUD WITH UPLIFFCONNECRONS.ROOF CONT CONTINUOUS Fr. PRESSURETREATED 0' ATTACHED DEC BALCONIES 60 Cr. CERAMIC71 E PNT. PAINTED S. THE DESIGNER HAS NOTBEEN ENGAGEDIFOR CONSTRUCTION SUPERVISION AND ASSUMES NO OVERHANGING THE RAKE SIDE OF Tilt BUILDING SHALLBE CONNECTED WITH UPLIFT DECKS 40 DENO. DEMOLISH PVC POLYVNVL CHLORIDE RESPONSIBILITY FOR CONSTRUCTION COORDINATING WITH THESEPLANS,NOR RESPONSIBILITY FORCONNECMONSINACCORDANCEVdlrHTABLE3.34 CONSTRUCTION MEANS,METHOM TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FORSAFETY 3, WALL-TO4VALLASSEMOLY.' ATITCS W/O STORAGE 10 DLL, DIAMETER RPC. REFLECTED CEILING PLAN PREPARATIONS AND PROGRAMS IN CONNECTION WITH THE WORK THEREARE NO WARRANTIES FOR WALLSTUDS ABOVE AND STUDS BELOW A FLOOR LEVEL SHALL HE ATTACHED WITH UPLIFT DESIGN LOAD CALCULATIONS ATTICSW/STORAGE 2 DR. DOOR REQ. REQUIRED A SPECIFIC USE EXPRESSED OR IMPLIED IN THE ME OFTHESE PLANS, CONNECTIONS IN ACCORDANCE WITH TABLE 3.3b.WHEN WALL STUDS ABOVE DO NOT FALL IN LINE (LIVE LOADS PSF) ROOF(GROUND SNOW LOAD) PER NYS CODE DWO. DRAWING JIM. ROOM G. REFER TO THE WINDOW AND DOOR SCHEDULE FOR EXTERIOR OPENINGS. WITH STUDS BELOW,THE STUDS SHALL BE ATTACHED TO A COMMON MEMBER IN THE FLOOR ROOMS(OTHER THAN SLEEPING) 40 EA. EACH FLO. ROUGH OPENING 7. THEGENERAL CONTRACTOR IS TO ENSIMEIFHAT MASONRYOR PREFABRICATED FIREPLACES MEETS ASSEMBLY WITH UPLIFT CONNECTORS IN ACCORDANCEWITH TABLE3,& ROOMS(SLEEPING) 30 ELEC, ELECTRICAL SIM. SIMILAR OR EXCE MANUFACTURES SPECIFICATIONS AND APPLICATION CODES. STAIRS 40 ELEV. ELEVATION SPEC. SPECIR D IL EDS 4. WALLASSEMBLYTOPOUNDAMON. GUARDRAILS(ANYDIRECTION) 200 m EQUAL STL STEEL THE GENERAL CONTRACTOR 15 TO CONSULT WITH THE OWNER FOR ALLBUILT4N ITEMS SUCH AS FIRSTIVALLSIUDS SHALL BE CONNECTED TO THE FOUNDATION,SILL PLATE OR soTrom PLATE BOOKCASES,SHELVING.PANTRY,CLOSETS,TOWS,ETC WITH UPLIFT CONNECTORS.STEELSTRAPS SHALL HAVE A MINIMUM EMBEDMENT OF 7 INCHES IN EXIST. EXISTING T&G TONGUEANOGROOVE 9. WIND LOAD REQUIREMENTS SHALL BE TAKEN INTO ACCOUNT DURING CONSTRUCTION. CONCRETE FOUNDATION AND SEASON-GRADE IS INCHES IN MASONRY BLOCK FOUNDATIONS,OR EXPOSURE CATEGORY DESIGN FOR CAT.C EXT. EXTERIOR TEL TELEPHONE LAPPED UNDER THE PLATE AND NAILED IN ACCORDANCE WITH TABLE&3b,WHEN STEEL STRAPS F.P. FIREPLACE TBO 70SEDEYERANNED gmu- ARELAPPED UNDER THE BOTTOM PLATE 3 INCH SQUAREWASHERS SKALLBE USED WITHTHE LOAD PATH SEE CONSTRUCTU)NAND WIND PATHCONNECTION DETAIL PAGE Pit FRENCH TO. Toper GINS GYpsUmWALL 3.22.INADDIFION TO SPACING,ANCHOR BOLTS ARETO RESPACED BETWEEN 6,12 INCHES FROM END UNLESS NOTED OTHERWISE ANCHOR SOLTS.ANCHOR BOLTSPACINr IS TO BESPACED AND SUED IN ACCORDANCE TO TAME (RO0E-FOUNDA-11ION) ANDGENERALN07ES GAEY. GALVANMED aOAfID TIP, TYPICAL THE IND OFA SILL PLATE ANDALL CORNERS. MAIUNGSCHEDULE SEE GENERAL NOTE PAGE HVAC HEATING,VENTING& WIF VERIFY IN FIELD 1. THEGENERAL CONTRACTOR AND MASON To REVIEW PLANS,ELEVATIONS,DETAILS AND NOTES TO S. TYPE I EXTERIOR SHEkRWALLCONNEMOldr. AIR CONDITIONING Wl WITH DEFERMINEINTENDED HEIGHTS OF FiNtSHED FLOOR(S)ABOVEMCALGRAOF TYPE I EXTERIOR SHEAR WALLS WITH A MINIMUM OF�&VIGH WOOD STRUCTURAL PANGLON THE INSUL INSULATION WD. WOOD 2. ALL FOOTINGS To REST ON UNDISTURBED(VIRGIN)SOIL EXTERIOR ATTACHED WITH 8d COMMON NAILS AT G*O.C.A THE PANEL EGGS AND 12 OZ.IN THE EGRESS SEE FLOOR PLANS AND WINDGVISCHEIDULE ENT. :NTEFUOR WE, WATER Pnoor EX 3. PROVIDE}' PANSION JOUJIMATERIAL BETWEEN CONCRETE SLABS AND ABUTTING CONCRETE OR FIELD,ANDJINC14 GYPSUM WALLBOARD ON THE INTERIOR ATTACHED WITH Od COATED NAILS AT S NPOUNDS SWING Xps EXTRUDED POLYSTYRENE Las NTERI O.C.PANEL EDGES AND 10'O.C.IN THE FIELD SHALLBE IN ACCORDANCIEWITH WE LENGTH 011ECTION SMOKE ALARMS TO COMPLYWITH NFPA 72 AND WS R314 PIC. OKE&CO20EW=ORS) ARC. -Z. MASONRYWAL15CCCURIFUNG tNEXI IORGRUNHEATEDI OR AREAS. ISM FIREPR om MAXIMUM ANY NEW CONCRETE WALLS EXISFINGOONCRETESTRUCTLIRESKALLBE REQUUMMENTSSFOCIFIEDINTABLE11M34. CARBON MONOXIDE ALARMS TO COMPLYWITH RalS 4. BEIM ATTACHED ED MO. MASONRY OPENING INSTALLED WITH 05 RE-BAR,IW LONG AT 12-Ot�LISEAPPROVIED EPDXY FOR INSTALLATION. & TYPE 11 OUMIORSHE40WALL CONNECTIONR S. UNLESS OTHERWISE NOTED,ALL SLABS ON GIMDETO OC4000 PSL CONCRETE TO BE POURED ON w TYPE 11 EMIORS14EARWALLS SHALL MEETTHE REQUIREMENTS OF TABLE 34S bTIMES THE ENERGY CALCULATRMs 2020IECC THICK SAND OR GRAVEL FILL WITH 6.6 WIRE MESH REINFORCING,INTERIOR SUMS TO BE MINIMUM 4" APPROPRIATE LENGTH ADJUSTMENT FACTORS IN TABLE 3.16, 7HWKALLFILLTOBE COMPACTED To 906 RELATIVE DOLE"WITH 8 INCH MAXIMUM LIFTS(LAYERSI, 7. INTERIORSHEARWALLCONNWITOW- S. CRAWLSPACSTO BE PROVIDED WITH A MINIMUM 18WV ACCESS OPENING,INSIALLONE 8xiG ALLOWABLE SIDEWALL LENGTHS PROVIDED IN TABLE3.14 SHALL BE PERMITTED TO BE CASrIRON FOUNDATION VENTrOR EVERY IWSQ/FTOFAREA. INCREASED WHEN INTERIOR SREARWALLS ARE USED.SHEATHING AND CONNECTIONS SHALL BE IN 7. CAMPROOF EXTERIOR OF FOUNDATION WITH BITUMINOUS COATING AS REQUIRED BY CURRENT KYA ACCORDANCE V40 2-4A.2 AND 2.24 RESPECTIVELY. ag CONSTRUCTION CODE A SMIL POLYETHYLENE FILM SHALLBEAPPLIED OVER THE BELOW GRACE B. CONNECTIONS AROUND EXTERIOR WALLOPENINGS. g PORTION OF EXTERIOR WALLS PRIORTO RACKFILLING, HEADER AND/OR GIRDER CONNECTIONS SHALL BEATIACHED WITH UPLIFT CONNECTIONS IN 8. DRA114AOEAS REQUIRED ElYCLORENI'MY-SS,CONSTRUCTION CODE A00DRDANCEWITH TABLE 3.5 WINDOWSILL PLATES SHALL HIWE CONNECTIONSHI ACCORDANCE -GROUND WIND SEISMIC FROST # WRITER SCESIDEMLI) WITHWLE3a SNOW SPEED DESIGN JWFATHERINGJ LINE TERMITE DECAY DESIGN UNDERLAY ENT FLOOD 9. CATHEDRAL CERING ASSEMBLY. LOAD (MINI CATEGORY DEPTHI. I REQUIRED HAZARDS WHEREA RIDGE IS TO BE USED ASA STRUCTURAL BE4MTHE RAFTERS SHALL OMER BE I STANIIARD NOTCHED AND ANCHORED,ON TOP OFTHE BEAM OR SLOPE CONNECTIONSSRALL BEATTACHED TO 30PSF 130 El SEVERE _. , EDGING YES EACH RAFTER.TO.RIDGEALONG THE OPF14 CEILING PARTOF THE BUILDING.CONNECTIONS TO TIES L ALL FRAJffING TECHNIQUES AND METHODS AS PRESCRIPTIVE DESIGN OF CURREATSBC HIGH WINDRIDGEAND WALLSHALL BEAITAC"W WITH THE ABOVE REQUIREMENTS, ADDITY) WOOD FRAMING CONSTRUCTION MANUAL N=ENOM,ALL FRAMING AND STRUCTURAL MATERIALTO BE 2. UNLESS 0 am DOUGLAS FUL MIN 3. FLOORS,WALLS,CEILINGS AND RAFTERS 70 BE SPACED AT W 0,0.UNLESS OTHER WISENOTED, 4. UNLESS OTHERWISENaTED.ALLSEARINO WALL HEADERSTO 89(2)2xlO#2+SEN.DOUG.FIR. FRISLOCKING REQUIRED-BY CURRENT WS CODE 2020 BEARING WALL HEADERS TO HAVE(2)JACK STUDS AND(2)FULL LENGTH STUDS ON EACH SIDE OFALL FIREBLOCHING SHALL BE PROVIDED TO CUT OFF ALCONCEALED DRAFT OPENINGS(BOTH VERTICALAND NAILSPACING AT PANEL NAILSFACINGATINFERMEDtATE OPZNEN HORIZONTAL)AND TO FORMAN EFFECTIVE FIRE BARRIER BETWEEN SWRESAND BETWEEN ATOP SHEATHING LOCATION G&LVLWADERS70 HAVE(3)JACKSTUDS AND(2)FULL LENGTH STUDS ON EACH SIDE OF EDGES SUPPORTS INTHE PANEL FIELD 'D i OPENINGS.BEARINGWALL WINDOW SILLS SHALLALSO RANE(2)WINDOW SILLPLATES FOR 2.4 WALL STOITYAND THE VIDEO,SPACE RRE13LOCIUNGSKqMBEPRDVIDEDINWOOD4R=ECONSMCnONI OPENINGS BETWEEN 4--r AND W-O'AND 296WALL OPENINGS BETWEEN V-11"AND TTIEFOLLOWINGLoCATIaN& 811COMMONGSIO.C. 86GOMMON06-O.C. W-S'.FFIOVIDE ZONE PIRESFOPANO BLOCKINOWHEREAPPLICABLE 1. IN CONCEALED SPACES OFSTUD WALLS AND PARITEMMS,INCLUDING FURRED SPACKATTHE 5. ALLFLUSHSEAMS/HEADERS To EE INSTALLED WITH HEAVY DUTY GALVANIZED HANGERS AND COUNGAND FLOOR LEVELS.CONCEALED HORIZONTAL FURREDSPACES SHALL ALSO BE INTERIOR ZONE ad COMMON @ 6,D.C. SdODMMONG I,O.C. ANCHORS WHERE APPILICABLETO ALL CONNECTING JOISTS. FIREBLONED AT INTERVALS NOT EXCEEDING 10 FEET.BATTS OR BLANKETS OF MINERAL OR ---- DWALL RAKE G. DOUBLE UP FLOOR JOISTS UNDER WALLS THAT RUN PARALLEL TO THE FLOOR JOINIS AND UNDER GLASS FIBER SHALL 69 ALLOWED AS FIRESLOCKNO IN WALLS CONSTRUCTED USING PARALLEL OdOOMMONSIPO.C. RE!COMMON 04 O.C. BATHTUBS FLOORS TO HAVECERAM[C THE IN15TAUED SHALL REVERIFIED FOR PROPER LOAD ROM OF STUDS OR STAGGERED STUDS. ANDRAKETRUSS CAPAC97YUNLESS NOTED ON PLANS 2. AFALLINTERCONNECI[IONS BETWEENCONCEALEOVERTICALAND HORIZONtALSFACES SUCH AS jA� 7. PRMDE(2)1,3/4-THICK MICRCLAMS(HEIG?IrTO MATCH FLOOR JOISM AROUNDSTAIRIVELL. OCCUR ATSOFITFS,DROP CEILINGS AND COVE CEILINGS q I to AND/OR OTHER ACCESS OPENINGS UNLESS OTHERWISE NGTEP(lYPICAL), 3. IN CONCEALED SPAC85 REIWSIV STAIR STRINGERS AT THE TOP AND BOTTOM OFTHE RUN. i 8. DORMERS RUNNING UP FLOOR RAFTERS ARETO BE SUPPORTED BY DOUBLE RAFTERS 019 EITHER SIDE ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH CURRENT MYS RESIDENTIAL CODE. SHEATHING LOCATION NAILSPACINGATPAMEL INTERMEDIATE SPACING AT INTERMIATE WHERE APPLICABLE UNLESS OTHERWISE NOTED. 4. AT THE OPENINGS AROUND Vem PIPES AND DUCTS AT CEILING AND FLOOR LEVEE,TO RESIST EGGS SUPPORTS IN THE PANEL FIELD 9. PROVIDE BLGCMN"MOGING IN FLOOR 1095M AT W-0-C.C-USE SOLID BLOCKING IN FLOOR JOISTS THE FREE PASSAGE OF FLAMEAND PRODUCTS OF COMBUSTION. UNDER ALL SEMINGIVALLEL 4'EDGEZONE BdCDMMONGG'O.C. BdCDMMONOI--O.M 10,PROVIDE INSULATION RAFFLESAT EAVEVENTS BETWEEN RAFTERS,INSTALL DRAFT BLOCKING As MONGG-O.C. adcommoNalro.c. 1,7�j- INTIFRIORZONE 8d DOM '�O NEEDED, I 12.UNLESS OTHERWISE NOTEDAll ROOFS AND WALLS To HAVEA MINIMUMJ'THfCK,4 PLY PER COX EXTSIORSHEATHING GRACE PLYWOOD.PLYWOOD TO COVER OVER PLATS AND HEADERS. IZ UNLESS OTHERWISE NOTED USE t THIGH T&G,FEES FIR OR ADVANTECH PLYWOOD SURFLOOR :L ALL WATER SUPPLY,DRAINAGE AND VENTING TO BE WALLED AS PER N.Y.&CONSTRUCTION CODE-2020. ADHERED WITH PL400 ADHESIVE AND SMEWEO TO FLOOR JOISTS,FINISHED FLOOR TO BE INSTALLED IF 4 OVER SUBFLGOR AS PER MANUFACTURES INSTRUCTIONS. 2. WALL STUDS,PLATES OR JOISTS ARE CUT OUT DURING INSTALLATION FOR ANY PLUMBING RELATED 13.ALL BATHROOM WALLS TO HAVEJ'THICK MOISTURE-RESISTANT SHEETROCK.GARAGE WALLS WORK,PROVIDE ADEQUATE GRACING AND PLATES TO PROTECTAND SECURE STRUCTURE.VERIFY WITH THESTAFE CODEAND MANUFACTURES RECOMMENDATION FOR MAXIMUM HOLESIZE AND CEIUNGS ANDOVER FURNACE TO HAVEPTHICK TYP&XSHEEMOCK.ALL OTHER PARTS OF BUILDING SPACING PERMITTED. MARK LOCATION SIMPSONIIE* INSTALL NOTES TO HAVE REGULARkSHEEMOCJI ALLINALLS TO BETAPED AND FINISHED, 14,ALLROOFWnH A PITCH LESS THAN 4d2SHALL REINSTALLED WITH AN ICE&WATER BARRIER OR AMMED EQUAL FIAT ROOFS SHALL BE APPLIED WITH A FIBERGLASS BASESHEETWITH AN EPDM -;v MO, I ROOFRIDGE LSTA/lS EVERY RAFT 20GA-1i-XI5 OR, "p-111 2 RAFrER/WALL 15.ALL SILL PLATES AND WOOD IbFCONTACrWfW CONCRETETO BE PRESSURETREATED.SELL PLATES TORCH DOWN TYPE MATMIALOVER a.'wl 100 2 LSTA(16 EVERY RAFT 12GA-li-916 A TO BE INSTALLED WITH A FOAM SILLGASKETAND COP4t-TEX TERMITE SHIELD OR APPROVED EQUAL L MECHANICALSUBCONTIFILICTOR IS RESPONSIBLE FOR ADHERING TOALLAPPLICABLE CODESAND 3 WALL/WALL LSTA(21 EVERY STUD 20GA-1i'x21 SAFETYREQUIREMENM Z HVACSUBCONTRACTOR IS TO FULLY COGROINATEALLSYSTEM DATAAND REQUIREMENTS IV[THINE EQUIPMEITISUPPLIER 4 WALL/BASE Pl. f�4411VERY STUD 2OGA-2j'x4j SCTM#1000-37-4-9 & HVACSUBCONTRACTORTO PR&ADEFINALSYSTEMLAYOUFDRAMnNGAND SUBMITITTOTHE L ALLELECTRICAL BEINSTALLED ASPER N.V-S.00NISTRUCTIONCODF GENERALCDNTRACTOR AND OWNER FOR FINAL ReVIEWAND APPROVAL IS BASE L/VOUND jr _..O_ ._O.C. ADDASNEWED 2. ALL ELECTIUCALWORK SHALL BEAPPROVED BYA QUALIFIED UNDERWRITER. 3 ALL ELMMCALWORK70 COMPLYWITH 2017 NEC. iw # ISSUE REVISION DATE 4. FNSTALLSMOKE DETECTORS AND CARBON MONOXIDE DETECTORS THROUGHOUTAS PER THE ISO& Xk' a ALL71ESTO BE SIMPSON STRONG TIES OR EQUIVALENT NVs CODE 'yy ALL FRAMING 10 BE FASTENED IN CONFORMANCE WITH. 1 FOR PERMIT 01JU24 IRCOODE-2020 s-Ml RNI'll? TABLE R602.3(l)-GENERAL L PNovjDEtTvPE-xsHmrroom FmFsmprtNGATivv MAXIMUM DISTANCES FOR NON TABLER6023M-SHFATHING ACCESSIBLEAREAS. TABLER802-9(9)-FRAMING-ROOF 2 :L THIS DESIGN COMPETES WITH THE 2=0 MC ENERGYCODEAS A PRESCRIPTIVE DESIGN. 2 USESIMPSON HANGERS ANDANCHORS WITH Z-MAXTRIPLE PROTECTIVECOATING FOR CONTACT Z THE DESIGN CONSTRUCTION SHALLCOMPLYWITH SECTION R402 OFTHE20:18 IBC. WITH AGO, PER SPEC 18ORAAm=20 MC I NTS SUPPLEMENTAL DESIGN- 3. PRESCRIPTIVE DESIGN-APPLIED AS PER CURRENT ENERGY CODE THE FOLLOWING EL04EMS ARE 3. INSTALL I-CO2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. WIND SPEED IS 130 MPH INCLUDED-R"IWAUS/FLOORS/aMEME?rr/FOUNDA-rION.VENTILATIOIL 4. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO ASCERTAIN ALL PREVAILING PROCEDURES 3 INCLUDING STORAGE AND TOILET FACILITIES,PROTECTION OF EXISTING WORK TO REMAIN,ACCESS W OF ew TO WORKAREA.HOURS OFPERMFFTED WORN AVAILABILITY OF WATER AND ELECTRIC POWER AND ALLOTHER CONDDTOXSAND RESTRICTIONS FORTHIS PARTICULAR LOCATION IN ORDERTO EXECUTEQA THEWORK IN ACAREFUL AND ORDERLY MANNER WITH THE LEAST"POSSIBLEDISIURRANCE'll)THECJ 4 PUBLIC. ROOF FRAMING, PER20WHIC-CHAPTS8 ""'DONTRACTOR SHALL MAKE THE NECESSARY ARRANGEMENTS TO UTILITIES AND SERVICES WALL FRAMING: PER2020IBC-CKAPTMG DRAWN BY: J- NEW FILL TO BE CLEM OF ORGANIC MATERIAL CONTRACTOR TO VERIFY EXISTING SOIL CONDITIONS TEMPORARILY DISCONNECTED WHILE PERFORMING WE WORK AS REQUIRED. FLOOR FRAMING: PER 2020 IBC:CHAPTERS N.J.MA72AFERRO,P.E. PRIOR TO FELL REMOVE AND ADD ADDITIONAL FILL AS NEEDED. 6. IN THE COURSE OF CONSTRUCTION,A CONDITION EXISTS WHICH DLSAGREES WITH IHATAS ROOFSHEATHING, PER 20MIDD•C KS 2. COMPACTION OFNEW FILL SHALL BE AT LEAST Sr%PROCTOR DENSITY(PER ASTM D 698 AND ASTIR INDICATED ON THESE DRAWINGS,THE CONFRACAIRSHALL STOP WORK AND NOTIFYTHE DESIGN CEILING SHEATHING: PER 2=100-CHMAPMTEMR DATE: D lSSn COMPACTTHESGILAT ir LEVIS VVFW4 CONTRACTOR TO HAVE FILLIFESTED,BY A OR THE ENGINEER IMMEDIATELY,SHOULD HE FAILTO FOLLOWTHIS PROCEDUREAND CONTINUE WALL SHEATHIMM PER 2020 IBC-CHAPTER 7 PROFESSIONAL ENGINEER PROFESSIONAL AGENCY FOR COMPACTION. WORK,HESHALL ASSUME ALL RESPONSIBILITY AND LIABILITY ARISING THEREFITOM, FLOOR SHEATHING: PER2020IBC-CHAPTMS 0 01/04/24 P.O.BOX 57,GREENPORT NY,11944 SCALE: 516.457,5596 EMAIL:maz_lin@msn.com 410. 057 RESIDENTIAL SHEET NO: rEsslot 2435 CEDAR LANE EAST MARION,NY 11939 G-1 SEAL r - - - - - - - - - -I r- - - - - - - - - -, L- - - - - - - - - - - - - -I I I— — — — — — — — — — — — — — 1 I I l 50% OF DECK STRUCTURE TO \ i \ REMAIN - FOUNDATION FRAMING I I \ I I \ I I \ I I \ I I \ I I \ — \ , I EXISTING DECK FOUNDATION \ \ TO REMAIN \ I I \ I I \ I I \ I REPLACE DECK BOARDS IN-KIND \ r B I \ I \ r I \ REPAIR MASONRY SURFACE AS REG. °' co EXISTING PATIO EXISTING BASEMENT 8'-8° iattc — - i'E S e DECK BOARDS REPLACED IN-KIND W/ EXISTING SUPPORTS. REPAIR FRAMING 1 I AS REQUIRED. 50% OF DECK FRAMING I AND FOUNDATION TO REMAIN SCTM# 1000-37-4-9 6X6 ACQ POST I W/14°DfA. PIER I N 3'BELOW GRADE I # ISSUE/REVISION DATE x (TYPICAL) I N 1 FOR PERMIT 01/04/24 - - - - - - - - - - - - - -� _ --T 2 REVISED 02/21/24 NO WORK REQUIRED ON EXISTING g 7'-II 3/4" 7'-II3/4 BUILDING FOUNDATION 17'-nY{ q , New 3 YO A 5 y.m 'Pir 4 BY. N.J.MAZZAFERRO,P.E. DRAWN 1 V a ® PROFESSIONAL ENGINEER DA . Di/04124 a x P.O.BOX 57,GREENPORT NY,11944 SCALE: EXISTING FOUNDATION PLAN PROPOSED FOUNDATION PLAN 516.457.5596 EMAIL:mazlin@msn.com SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" : '�p � 05709 �a� RESIDENTIAL SHEET NO: AROFESSlO��� 2435 CEDAR LANE A �� EAST MARION, NY 11939 A SEAL r za'-(o° 12' 16'-10' m EXISTING DECK TO REMAIN REPLACE EXISTING DECK BOARDS AND RAILINGS 50%OF DECK ELEMENTS TO REMAIN EX STING DECK EXISTING DECK UP a 31'-10° 6'_9" L 6'-9" 6'-9" :4:'-2" z g ►- ? q,'�i0 INSTALL-(4)6'-0"X6'8° z_ EX.MASONRY INSTALL NEW WINDOW w-3 RAISED PATIO REMOVED RAISED IN EXISTING OPENING ANDERSEN SLIDERS w¢ c FLOOR IN THIS AREA ARM(4'-0"WIDE) g NEW OUTDOOR LIVING ROOM DINING ROOM MA SONRY DINING ROOM ui .{OWE L 56R_5T �' L LIVING ROOM a U _ 1RAISED PATIO NEW NEW STAIRCASE R ' - 3'x3' 14R-13T W/RAILING - r U. WALL &LANDING • (�jIJ/�,(.Jf� 4' �vv NEW CLOSET CH N F /J I � 4° Nm N �L Joe— INSTALL 2-2"XIO`HEADER -- -------� NEW POCKET 8'-7" P� 8 4'WIDE CLOSET DOOR DOOR MIN.32' t ;r'�. BALCONY ABOVE EX. BEDROOM BEDROOM NO. I BEDROOM N0.2 FIREPLACE No_2 EX.BEDROOM FIREPLACE No.l — — REMOVE DOOR (BALCONY IS 8'-6°AFF) a NOTE: I na-JI ALL WINDOWS AND DOORS WASHER NEW CLOSET TO BE ANDERSEN A400 V. DRYER DEMO STAIRCASE \?RZWLi sni LD SERIES - LOW E GLASS 3°-' ENERGY RATED KITCHEN r02gH EX. BAHKIT � NEW 3'-0° RENOVATED KITCHEN OALTERED ENTRY DOOR O ---- o 2° 1 I (o I 001I -� 1 �D ALFZo ENTRY DECK BATH ENTRY DECK a STEPS 2 4_ &STEPS SCTM#1000-37-4-9 EX. DECK #� ISSUE/REVISION DATE LOWER DECK REPLACE EXISTING DECK BOARDS&RAILINGS o SHED SHED G 50%OF DECK ELEMENTS TO REMAIN TO REMAIN ra�SaH_OWER R EXIST- 1 FOR PERMIT 01/04/24 o DOOR SHOWER 2 REVISED 02l21l24 ------------------------------- 3 ------------------------------- .��0 VE�li ------------------------------ I N.J.MAZZAFERRO,P.E. DRAWN BY: KS PROFESSIONAL ENGINEER DA 01,�1� tS EXISTING FIRST FLOOR PLAN PROPOSED FIRST FLOOR PLAN LeiP.O.BOX 57,GREENPDRT NY,1,944 SCALE: 516.457.5596 EMAIL:maz_lin@msn.com SCALE: 1/8"=1'-0" "_ ' e� 1 SCALE: I/8'-I -0' �"10 'ti0 051 ,�'°�a? % RESIDENTIAL SHEETNO: dot, s 2435 CEDAR LANE EAST MARION, NY 11939 SEAL OPEN TO BELOW NEW WALL-INTERIOR 2X4 STUDS NEW STAIRCASE 3'x3' 14R-13T W/RAILING NEW CLOSET STAIR HALL EX.STAIR HALL BEDROOM No.4 EX. BEDROOM BEDROOM No. 3 CHIMNEY EX. BEDROOM cHIMNE No_4 No, e • RE OVATED BATH BATHROOM DEMO STAIRCASE O � 0, F OPEN TO BELOW INSTALL NEW WINDOW IN EXISTING OPENING-A21 EXISTING SECOND FLOOR PLAN PROPOSED SECOND FLOOR PLAN SCTM# 1000-37-4-9 SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" # ISSUE/REVISION DATE 1 FOR PERMIT 01/04/24 2 ryOF N . , 3 Y 4 N.J.MAZZAFERRO,P.E. DRA KS BY: j PROFESSIONAL ENGINEER DATE: OIAW24 r (u P.O.BOX 57,GREENPORT NY,11944 SCALE: = 516.457.5596 EMAIL,maz—lin@msn.com 1/8"=11-0" 1 057a �� RESIDENTIAL SHEET NO: S100 2435 CEDAR LANE /� �� EAST MARION, NY 11939 f1 SEAL 1 TREX COMPOSITE TOP RAIL POST CAP INFILL(TYP) Q POST SLEEVE CABLE RAIL TREX COMPOSITE TOE RAIL POST SKIRT REUSE EXISTING 12 5/4X6 TREX COMPOSITE DECKING v EXISTING DECK RAILING AND DECKING EXISTING SCALE: NTS 12 6 F-1 2XI0 RIDGE NEW DECK BOARDS&RAILINGS Li I --- RAILING P — 2X8 RR @16"OCL U EXISTING Q EXIST. 2X8 DJ @I6°O.C. SHED NEW I/2 RENOVATED (3)2X8 GIRDER EXISTING BATH BATH N 2X8 LEDGER 6X6 ACQ POST FLASHED ---- P REPAIR FRAMING 14"DIA. a. ' AS REQUIRED CLOSET --- CONC. r 50%TO REMAIN PIER 1. 14 EXISTING REUSE EXISTING SISTER 2X8s W/EX.STUDS EXISTING SECTION A EXISTING a° SCALE: NTS ' a EXISTING EXISTING p SCTM# 1000-37-4-9 EXISTING P # DATE ISSUE/REVISION 1 FOR PERMIT 01/04/24 SECTION B 2 REVISED 02/21/24 SCALE: NTS 0 ly'e& 3 J 0'4'ir 4 N.J.MAZZAFERRO,P.E. DRAWN_ 70® PROFESSIONAL ENGINEER DATE:01/04124 W P.O.BOX 57,GREENPORT NY,11944 SCALE: 516.457.5596 EMAIL:m4zjln@msn.com NTS ©A - o5?m9 ,�' RESIDENTIAL SHEET NO: 2435 CEDAR LANE EAST MARION, NY 11939 A-4 SEAL 1. frT � ..-..r .?�.....A.'••`I•:i'�..�� � ����,•.V �::.. i• Sa.• •+ .YZ j. ,55.'.�'�t`,•'I�• f� ••�: ,��ti�•...mot.•,.�� �.¢r�y�;.t• 'mot• •:•{.�"•. :�",.0� � � - FRONT ELEVATION (STRUCTURE REMAIN AS EXISTING) SCALE: 1/4"=1'-0" SCTM#1000-374-9 # ISSUE/REVISION DATE 1 FOR PERMIT 01/04/24 2 ' 3 OF N I. t 9� N.J.MAZZAFERRO,P.E. DRAWN IcsS BY: PROFESSIONAL ENGINEER DATE: 01/04/24 ® P.O.BOX 57,GREENPORT NY,11944 SCALE: L l P 516.457.5596 EMAIL:maz tin@msn.com 1/4"=1'-0" RESIDENTIAL SHEET NO: end O�ESSION��� 2435 CEDAR LANE /� EAST MARION,NY 11939 A-5 ' SEAL c 3 1.1/4 I JIV12 111401 TUB LAV W.C. 2ND FLOOR C.O. 2 3 1.1 4 � 3 1114 11/4 11/4 11,/2 11/4 41 1.1/2 41 1V LAV LA KIT SINK W.C. W.C. DISH 7SHOWER WASHER WASHER 1ST FLOOR 3"F.AI I. 111441 C.O. 3 2 1.1/4 2 341 l C.O. 3 �114 3 4 TRAP HOUSE S p�cXtSTING sysTFM RISER DIAGRAM SCALE: NTS SCTM#1000-37-4-9 # ISSUE/REVISION DATE 1 FOR PERMIT 01/04/24 2 O NE Yo 3 4 c� N.J.MAZZAFERRO,P.E. DRAWN BY: •.o PROFESSIONAL ENGINEER DATE: ' t.1 01/04/24 P.O.BOX 57,GREENPORT NY,11944 SCALE: 516A57.5596 EMAIL:maz—lln@msn.com NTS �o 41, ®S�p9y RESIDENTIAL SHEET NO: �rYQFSsio��� 2435 CEDAR LANE A�c EAST MARION, NY 11939 A V SEA