HomeMy WebLinkAbout52439-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52439 Date: 11/07/2025
Permission is hereby granted to:
George Dapontes
c/o Maria Dougherty
East Elmhurst, NY 11370
To:
Construct a new single-family dwelling with breezeway to detached garage and HVAC system as
applied for per SCHD approvals.
Premises Located at:
1050 Tasker Ln, Greenport, NY 11944
SCTM#33.-4-36
Pursuant to application dated 09/30/2025 and approved by the Building Inspector.
To expire on 11/07/2027.
Contractors:
Required Inspections:
Fees:
Single Family Dwelling-NEW $3,289.00
CO Single Family Dwelling-New $100.00
Total $3,389.00
Building Inspector
1de�
qw4 TOWN OF SOUTHOLD —BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 tt s; southold�tonm g v
rtN
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only E C E E
PERMIT NO. 1 1 Building Inspector.,
S E P 3 0 2125
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant Is not the owner,an Building D P rtm nt
Owner's Authorization form(Page 2)shall be completed. Town of Southold
Date:SEPTEMBER 29, 2025
OWNER(S)OF PROPERTY:
Name: DARIUS MROCZKOWSKI SCTM # 1000-033.00-04.00-036.000
11 Project Address: 1050 TASKER LANE GREENPORT, NY
Phone#:516-807-4411 Email: RUSHBUILDINC@GMAIL.COM
Mailing Address: 11 LIVINGSTON STREET BAY SHORE, NY 11706
CONTACT PERSON:
Name:MICHAEL ORLANDO
Mailing Address: 11 LIVINGSTON STREET BAY SHORE, NY 11706
Phone#:5� �fb _ a3 _39c,1 Email:RUSHBUILDINC@GMAIL.COM
DESIGN PROFESSIONAL INFORMATION:
Name:TODD O'CONNELL
Mailing Address: 1200 VETERANS HWY SUITE 120 HAUPPAUGE, NY 11788
Phone#:631 .650.6666 Email:PERMITS@TOCARCHITECTS.COM
CONTRACTOR INFORMATION:
Name: iDgfl if 5 -L (� ( 0 Z-k J
Mailing Address: H (,1V1 n 5 5)-, Y n
Phone#: �-j S. -- ?(I, —q -1 b Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
i
®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated cost of Project:
❑Other $ 1,000,000.00
Will the lot be re-graded? Dyes igNo Will excess fill be removed from premises? ®Yes El No
1
PROPERTY INFORMATION
Existing use of property:VACANT Intended use of property: RESIDENTIAL
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R4 0 this property? ❑Yes ®No IF YES, PROVIDE A COPY.
8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): M, E kl 0�� � Authorized Agent ❑Owner
Signature of Applicant: Date: �-
STATE OF NEW YORK)
SS:
COUNTY OF
0 A^ being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the
(Contrcto Agent,' rporate Officer, etc.)
of said owner or owners, and is duly authorized to Dp or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of 20 9—
Notary Public
MIGDALIA A ROQUE
NOTARY PUBLIC,STATE OF NEW YORK
QUALIFIED
I01R061773781COUNTY
NO. PROPERTY OWNER AUTHORIZATION
COMMISSION EXPIRES 11/29/&Z'? (Where the applicant is not the owner)
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
'r� mnmmw�m
Town Hall Annexe �� Telephone(631)765-1802
'� 631
54375 Main Road �,„ Fax( )765-9502
P. O. Box 1179
Southold, NY 11971-0959 �
BUILDING DEPARTMENT
N01ICF O.FUT.ILIZA.TION OF TRUSS TYPE CONSTRUCTION PRE-ENGINEERED
WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION
Date:
Owner: .mm� � Q G... _o
.. ,vi C7
Location of Property: —
Please take notice that the (check applicable line):
y ..... New commercial or residential structure
Addition to existing commercial or residential structure
. mm Rehabilitation to an existing commercial or residential structure
to be constructed or performed at the subject property reference above will utilize
(check applicable line):
_ Truss type construction (TT)
Pre-engineered wood construction (PW)
Timber construction (TC)
in the following location(s) (check applicable line):
„ Floor framing, including girders and beams (F)
Roof framing (R)
Floor and roof framing (FR)
Signature:
Name (person submitting this form): --.........................a_w. . ._ _.._......__ . ._ . .. . _.........
Capacity (check applicable line):
Owner
Owner representative
TrussReg15.docx Effective 1/1/2015
L111,11, I'll,
r
REScheckoWeb"
Compliance Certificate
Project Information
Project Title: 1050 Tasker Lane
Energy Code: 2018 IECC
Location: Greenport, New York
Construction Type: Single Family
Project Type: New Construction
Project Sub Type: None
Conditioned Floor Area: 4414 ft2
Glazing Area: 23%
Climate Zone: 4a (5572 HDD)
Project No: 1759047
All Electric: false
Is Renewable: false
Has Battery: false
Has Charger: false
Has Heat Pump false
Construction Site: Owner/Agent: Designer/Contractor:
1050 Tasker Lane Mike Orlando
Greenport, NY 11944 516-238-3946
m.orlando@aol.com
Project Notes:
Envelope Assemblies
Prop. Req.
Assembly Gross Area or Cavity Cont. U- U- Prop. Req.
Perimeter R-Value R-Value Factor/ Factor/ UA UA
F-Factor F-Factor
Ceiling:Cathedral Ceiling 2258 30.0 0.0 0.034 0.026 77 59
Floor:All-Wood Joist/Truss 80 21.0 0.0 0.044 0.047 4 4
Wall: Wood Frame, 16"o,c. 3160 19.0 0.0 0.060 0.060 144 144
Window:Vinyl Frame 503 0.300 0.320 151 161
SHGC: 0.3
Door 1: Solid Door(under 21 0.140 0.320 3 7
50%glazing)
Door 1:Glass Door(over 229 0.300 0.320 69 73
50%glazing)
SHGC: 0.3
Wall 1: Wood Frame, 16" 250 13.0 0.0 0.082 0.060 19 14
o.c.
Door: Solid Door(under 21 0.140 0.320 3 7
50%glazing)
Basement Wall:Solid 1580 13.0 0.0 0,054 0.059 81 89
Concrete or Masonry
Wall height: 10.00
Insulation depth: 10.00'
Insulation position:
Integral Insulation
Window:Vinyl Frame 56 0.300 0.320 17 18
SHGC: 0.3
Door: Solid Door(under 21 0.140 0.320 3 7
50%glazing)
MEHIMEMENEMSEM
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules, It DOES
NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Compliance Statement
The proposed building design described here is consistent with the building plans,specifications, and other calculations
submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Matthew Larva -HERS Rater 9/23/25
Name - Title Signature Date
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 95%were addressed directly in the RESCheCk software
Text in the "Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being
claimed.Where compliance is itemized in a separate table,a reference to that table is provided.
Pre-inspection/Plan Review
Section Plans Field
# Verified Verified
& Req.ID Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
103.1, Construction drawings and Cj Complies
103.2 documentation demonstrate
[PR111 energy code co mpl'iance for the Does Not
build envelope.Thermal Comply
envelope represented on Not
construction documents, servable
Q Not
Applicable
1, Construction
drawings and ?Q Complies
103. demonstrate Does Not
403.7 energy code compliance for o
[PR3]1 lighting and mechanical Comply
systems, Systems serving, RNot
multiple dwelling units must servable
demonstrate compliance with
the IECC Commercial Provisions. Q Not
Applicable
302.1, Heating and coolin equipment Heating: Heating O Complies
i based on loads calculated per O Does Not
403.7 is size per ACCA anua S �Etu/hr Btu/hr p
[PR2] ACCA Manual] or other mthods u.� � J Comply i
approved by the cocle offirial. pCooling: 'Cooling: Q Not
l �h. .. a/h ' Observable
Q Not
4pplicable
Additional Comments/Assumptions:
(Tier
9 p pact(Tier 3)
1 Hi h Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Im
Foundation inspection
d Verified Verified
E 13 Foundation d t�er Inspection ei
._..,_ Complies? Carmert lAssurptiors
. ,,. xker�ordtive � I extends, Complies
xception.�,,,ew�._._u_.
p �covering � p � :Requirement
]f O ] p ,us not applicable.
a minimum of 6 in. below grade, Comply 1
Not
servable
PNot
pplicable
403.9 ,,.,,w o Snow-and ice-melting system Q Complies
[F012)a controls installed. Does Not
Comply
Q Not
Observable
Q Not
Applicable
402.1.1 Conditioned basement wall Complies See the Envelooe
[FO4]1 insulation R-value,Where R —J R Assemblies table for
interior insulation is used, _ Does Not values
verification may need to occur R' ..... R' ........m Comply 1
i
during Insulation Inspection, Not Not
rvagu�red pn warm-humid servable
locations in Climate Zone 3. Not
Pplicable
303.2 Conditioned basement wall Complies
[FO5]1 insulation installed per
manufacturer's instructions. Does Not
omply 1
i
Not
servable
Not
pplicable
i
402.2.9 Conditioned basement wall O Complies See the Envelope
[FO6]1 insulation depth of burial or ��ft ft Does Not Assemblies table for
distance from top of wall �m I values
py
j [2Not
servable
Not
Applicable
Additional Comments/Assumptions:
J
1 High Impact(Tier 1) � 2 Medium Impact(Tier 2) 3 LLow Impa . . ....3)
._ _ � m, ct(Tier 3)
Framing / Rough-In Inspection
S�cti'on Plans Fiel
# Framing!/'IOU h4n, Verifted Verified
d
& Req.10 inspect,019 Value Value Complies? Comments/Assumptions
1402.1.1. i Door U-factor. U Complies See the Envelope,
4023.4 O1 Assemblies table for
[FR111 Does Not values
Comply
Not
Observable
Not
pplicable
402.1.1, Glazing U-factor(area-weighted U= U= 0 Complies See the Envelope
402.3.1. average). Does Not Assemblies table for
P
1402.3.3. 0 values
402.5 mply
[FR211 PiNot
Observable
PNot
pplicable
402.4.1.1 Air barrier and thermal barrier complies
I[FR2311 installed per manufacturer's Does Not
instructions.
Pomply
PNot
servable
PNot
pplicable
1402.4.3 Fenestration that is not site built Q Complies
[FR2011 is listed and labeled as meeting
AAMA/WDMA/CSA Does Not
101A.S.2/A440 or has infiltration Pomply
rates per NFRC 400 that do not Not
exceed code limits. Poservable
PNot
pplicable
4014,5 IC-rated recessed lighting E3 Complies
'(FR1612 fixtures sealed at
housing/interior finish and Does Not
labeled to indicate:52.0 cfm Complyleakage at 75 Pa. PiNot
servable
PNot
pplicable
403.3.1 1 SUPPI and return ducts in attics Complies
[FR1211 Jnsulayed >= R-8 where duct is
>= 3 inches in diameter and Po Does Not
>= R-6 where< 3 inches. mply
Supply and return ducts in other Not
portions of the building 9servable
insuiated>= R-6 for diameter
>= 3 inches and R-4.2 for< 3 Not
inches in diameter. Ppplicable
403.3.2 Ducts,air handlers and filter Complies
[FR1311 boxes are sealed with
joints/seams compliant with 0 Does Not
1 International Mechanical Code Comply
I or International Residential Not
Code, as applicable. Rservable
PNot
pplicable
_403.3.5 Building cavities are not used as Complies
[FR1513 ducts or plenums.
PDoes Not
omply
9Not
servable
PNot
pplicable
----—----- ------- ---------
ectlo�� IFrlawrs i�iv�ldi
Rrarning/Rough-On Verified Verified
&Re+g.10 Inspection Value ValueComplies? Comments/Assumptions
4073.4 HVAC pipin conveying fluids � O Complies
[FR1711 above 105 QF or chilled fluids R � R"
below 55 4F are insulated to>_R- Does
Not3. 1
j UNot
servable
pNot
pplicable
403.4.1 Protection of insulation on HVAC Cj Complies
[FR24]1 piping. Does Not
Comply
�Not
servable
❑Not
applicable
53 Hot water pipes are insulated to y p
R �U R � Complies
[FRp :w >_ -g� R-3, � U I�Does Not j
Comply
QNot
servable
�Not
pplicable
403,6 Automatic or gravity dampers 0 Complies
[FR191 lle n a II outdoor air Does Not
stakes a ex
hausts. omply
PNot
servable
Not
Applicable
303.1.3 U-factors of fenestration O Complies
[FR4]1 products are determined in
accordance with the NFRC test Q Does Not
procedure or taken from the P-Imply
default table. Not
servable
PNot
plicable
Additional Comments/Assumptions:
J
i
High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Insulation Inspection
.._ ._..-.._.. . ...a_.... � �_..._e.w_ ... . .�..
Section Plans Field
# Verified Verified
& Req.ID Insulation Inspection Value Value Complies? Comments/Assumptions
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the
installed R-values
provided. ❑Does Not
Comply
Not
servable
❑Not
Applicable
402.1 1, Floor insulation R-value. p R, � ❑Complies See the Envelope
402.2 6 R� �.... Assemblies table for
os
[IN1]1 ❑Wood ❑Wood ❑Dpley Not values
❑Steel ❑Steel CQ Not
Observable
PpNot
plicable
303.2, Floor insulation installed per ❑Complies
402.2,8 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the Com I
underside of the subfloor,or P Y
floor framing cavity insulation is ( ]Not
in contact with the top side of O servable
sheathing, or continuous
Insulation is installed on the Not
underside of floor framing and Applicable
extends from the bottom to the
top of all perimeter floor
framing members.
402.2.5, a mass wall with at least /2 of WJood.;.. O Does Assemblies table
402 1.1, Wall insulation R value. Ifi his is R Complies See the
table for
q pp ❑
402.2.6 the wall insulation on the wall ❑ values
[IN3]1 exterior, the exterior insulation Mass Mass i Comply
requirement applies (FR10), ❑ RNot
❑Steel Steel servable
❑Not
Applicable j
303.2 Wall insulation is installed
1 manufacturer's instructions.per 1 Complies
[IN4] on �❑Does Not
Comply
(�Not
Observable
Not
Applicable
Additional Comments/Assumptions:
f
........ wuuwuwuw nnn mmi
1 Hi h Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Final inspection Provisions
Section Plans Field
# Verified Verified
& Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions
402,1 1, Ceiling insulation R-value. ......_, i R � R v I Complies Not See the
bl es elope
402.2 1 table for
402.2.2, Q Wood (�Wood valcomply
(FI1]1 Q Steel E)Steel ❑Not
Observable
Q Not
i Applicable
� .�a. _.._.. .
303.1.1.1. Ceiling insulation installed per Complies
303.2 manufacturer's instructions.
[F1211 Blown insulation marked every Does Not
300 ft2, nmply
Q Not
Observable
Not
pplicable
403.1.2 Heat pump thermostat installed OComplies Exception: Requirement
[FIJO]2 on heat pumps. O Does Not is not applicable.
Comply
(�Not
Observable
Q Not
Applicable
5.1 Circulating service hot water Complies
[FI11]2 systems have automatic or°
accessilble manual controls, Does Not
Umply
q Not
Observable
Not
Applicable
403.6.1 All mechanical ventilation Q Complies
[FI2512 system faros not part of tested
and listed WAC equipment Does Not
meet efficacy and air flow limits Comply
per Table R403.6.1. Not
servable
0 Not
Applicable
403.2 � Hot water'boilers supplying heat Q Complies �
[FI2612 through one-or two-pipe
heatiny systems have outdoor Does Not
setback control to lower boiler Comply
water temperature based on ;QNot
outdoor temperature. servable
❑Not
Applicable
e .�.�.�..,�.:.�... ......�.� .
...._._�.
403.5,1.1 Heated water circulation Complies
[FI28]2 systems have a circulation
Does Not
pumpF"I"he system return pipe is Co
a dedicated return pipe or a Comply
cold water supply pipe.Gravity (�Not
and thermos-syphon circulation O servable
sCstems are not(present,
ontrols for circulating hot Not
water system pumps start the pplicable
pump with signal for hot water
demand within the occu.rpancy,
Controls automatically turn off
the pump when water is In
circulation loop ns at set-point
temperature and no demand for
hot water exists.
403.5.1.2 Electric heat trace systems Q Complies
[F129]2 comply with(IEEE 515,1 or I.Ut
515.Controls automatically ❑Does Not
adjust the energy input to the Comply
heat tracing to maintain the Not
desired water temperature in servable
the piping.
o Not
Applicable
Section° � . .u._ .............---Plans —_ Fie. _
Id
# Verified Verified
& Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions
403,5.2 Demand
recirculation water Complies
[F130]2 systems have controls that
manage operation of the.pump Does Not
and IImit the temperature of the Comply
water entering the cold water Not
piping to<= 104°F. servable
Not
pplicable
f it
403.5.4 Drain water heat recovery units Complies
[FI31]z tested in accordance with CSA ,
B55.1. Potable water-side Does Not
pressure loss of drain water Comply
heat recovery units < 3 psi for o Not
individual units connected to Observable
one or two showers. Potable
water-side pressure loss of drain O Not
water heat recovery units < 2 Applicable
psi for individual units
connected to three or more
showers.
404.1 90%or more of permanent Complies
[FI6]1 fixtures have high efficacy
lamps. Does Not
Comply
6Not
servable
Not
Applicable
..404.1,1 Fuel gas lighting systems have Complies
[FI23]3 no continuous pilot light.
Does Not
Comply j
Not
OOservable
I
Not
Applicable
401.3 Compliance certificate posted. Q Complies
[FI7]2 Q Does Not
Comply
[]Not
observable
Q Not
Applicable
.............. �.
303.3 Manufacturer manuals for Ocomplies
[FI18]3 mechanical and water heating
systems have been provided. Does Not
Comply
O Not
Observable
Not
pp pplicable
402.2.3 Vented
adjacent to soffit with air ea eeable e .w 99 Complies
Exception: Requirement
[FI22] of a p,p cable.
vents that extends over Comply
insulation. ( J Not
Observable
O Not
Applicable
02,2,4 Attic access hatch and door R( fit QComplies
13]1 insulation_R-value of the b ........m> n
adjacent assembly. C Does Not
i omply
I[—]Not
O servable
No
t
Iicable
p
50 Pa.
[ 117]1 1 2 Blower i Cl in Climate Zones 3 g5 CH 50 C _ Q Does Complies
Not
u Comply j
❑Not
Observable
Q Not
Applicable
ectlorr Plans, Field
# Verified Verified
Req.10 Final Inspection Provisions Vailue Value Complies? CommentslAssumptions,
II - ------------
1403.3.3 Ducts are aiesstesteto E)Complies[F127]1 determiner leakage with reoh-in test: Total cfm/100 ft2 CfM/100 ft2 Po Does Not
mply
leakage measured with a
pressure differential of,0.1 inch Not
w.g,across the system including
Uservable
the manufacturer's air handier
I enclosure if installed at time of Not
test. Postconstruction test:Total i iPpplicable
leakage measured with a
pressure differential of 0,1 inch
w.g.across the entire system
i including the manufacturer's air
handier enclosure.
403.3.4 Duct tiphtness test result of 10 Complies
[F1411 <=4 c m1100 ft2 across the
I CfM/100 ft2 Does Not
system or<=:3 cfm/100 ft2 cfm/100 ft2
without air handier @ 25 Pa.For Imply
rough-in tests, verification may Not
need to occur du
ring Framing able
sery
inspection, Not
plicable
Pp
403.3,2.1 Air handler leakage desi vated Complies
[F12411 by manufacturer at<=2%of
design air flow. Does Not
Comply
❑Not
observable
p P Not
plicable
403AJ Programmable thermostats E)Complies
IF19p installed for control of primary
Does Not
heating and coaling systems
and initially set b manufacturer Comply
to code specificat.Lns, Not
Yservable
'P Not
p plicable
...................... ........
Additional Comments/Assumptions,
F3 Low Impact(Tier 3)
High Impact(Tier 1) 2 Medium Impact(Tier 2)
Effidency
Certificate
Above-Grade Wall 19.00
Below-Grade Wall 13.00
Floor 21.00
Ceiling/Roof 30.00
Ductwork(unconditioned spaces):
Window 0.30 0.30
Door 0.30 0.30
Skylight 0.00
. . . .
i REM
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments:
DEPARTMENT STANDARDS,REMOVE AND REPLACE UNSUITABLE
SOILS WITH SAND AND GRAVEL FOR A DIAMETER OF SIX FEET
GREATER THAN THE LEACHING POOL(3'COLLAR),
EXTENDING DOWN INTO A MINIMUM OF A 6'STRATA OF
ACCEPTABLE SAND AND GRAVEL
10.PVC PIPE TO BE INSTALLED IN ACCORDANCE WITH
APPENDIX E OF THE SUFFOLK COUNTY SANITARY CODE
11.PVC PIPE TO CONFORM TO ASTM D-3034,PIPE TO HAVE
co
SDR CLASSIFICATION OF 35
co
NOTE: CLEAN OUT MUST BE INSTALLED ON TREATMENT UNIT INLET LINE o
AT FACE OF BUILDING, }
IF INSTALLED AT EXTERIOR IT MUST BE TO GRADE. ¢ w
z �
Q 0
co z
N 6i
LEGEND o
TEST HOLE
PROPERTY LINE >
w
APROX WATER LINE
CW— LOCATION
L F PROPOSED LEACHING POOL
T U, PROPOSED TREATMENT UNIT
PROPOSED 50%EXPANTION TANK
w Z
PROPOSED 24"DISTRIBUTION BLOCK U W w
w 2zz
UJ
o > Qz
C/) Wow
0 0 �
0
a_ o C�
0 �
k q 'u W�skis" r� Fuji Clean co
cQHS APPI
Lu
� h
� ... _ ...... N N o z
9 1E 20
Lu
..
p I, 8. N p Q Z
C
CDw Q
aw of
W J
t
IvinI
Cb
��n C
x
q
4Q
60,
�
DW#1
23.5 do
x
o
o COVERED o
/ L
PORCH °
r
/ 40.0
C/E
0
k � 12.E
m o PROPOSED 1[4 M 2 STORY o
, (Z) / a_ - RESIDENCE COVERT
Az _ � F.F. EL. 38.5 PORCI
6.0
,Q a 18.0
cd / l ) M`
+35. 3
40.0
W/W PORTICO W/W
+3& L
WALKWAY
\ 8Ox12 1
LL
�/
EX.
C:) 1/ DW#2
Llj
CD
x
125. 82
�o
�z OH
OH
OH OH OH OH OH OH pH OH
rr� �r �r r-� •\ Irl IrA IT _n ��