Loading...
HomeMy WebLinkAbout52403-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52403 Date: 10/27/2025 Permission is hereby granted to: Craig Rosenberg 17 Southland Dr Glen Cove, NY 11542 To: Construct additions and alterations to an existing single-family dwelling as applied for. Project includes the removal of an existing shed and reduction of existing deck. Premises Located at: 685 Bridge St, Greenport, NY 11944 SCTM# 34.-3-53.3 Pursuant to application dated 07/24/2025 and approved by the Building Inspector. To expire on 10/27/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition&Alteration $848.00 CO Single Family Dwelling-Addition /Alteration $100.00 Total S948.00 dA Z� — — Building Inspector a; TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 l�tta ://wrv. olatholcltownxt �otr Date Received APPLICATION FOR BUILDING PERMIT v For Office Use Only 15—aL�. O j PERMI T NO. 1 Building Inspector:Ins r " r .. Lir.. . / -//I�J//Y//i0 �- fr/ PUEldIll7g DP'1P?Xrc^ ''v. / '/ f, �/% ,r///i J���%�'rrl%i ✓ i /pi���iU/ ��i7r r�i ,,//�/���,/!r,„, r /�/i „/it Town Sclt � „Gew.., �/,,;!��,�/�.r!, rli�� f�/I,,!�,/,/%L�lii,i r,..!�,lirf„�,,,�,�r,,,ir Gm/l�„u ,r ,�r%,,�,,,,..r,f' ,,,„, r/,�✓f Date: r r/ /ri f/ / � Gr /% / 1r//�////.✓r /%% /r/r, / // J.:/ /�/; //�ii/ rrir �o // r,- „ rr ./ r / , r � ��� Name: Laura & Crai Rosenber scTM # Z000- Project Address: 224 (aka 685) Bridge St. Greenport, NY Phone#: 631 235-9881 Email: laurarosenberg@live.com Mailing Address: 17 Southland Dr. Glen Cove, NY 11542 ri/f rr r/ W" i Name: Laura Rosenberg Mailing Address: 17 Southland Dr. Glen Cove, NY 11542 Phone#: 631 235-9881 Email: laurarosenberg@live.com r i r/•,. y : lrU n �%'. r, ,r, ..; rli, ,,,:'ii �r,,// r rir '.; s; �r / %/, r/, ri, it l r ,J✓,GJ,•, rr/,..,,// (/i!r/rl„i,/,/,,, ,l,.rl//e,....a ///„ /. J..oi .✓ 0/,,.,,.6 /, e/ r r .lr rr :,: r ,�� ;..,/,,i , r „/Ire` //,,, ( rYr! ,a //i/ri•//ri%r%o!%U% i :/r,- /%/rl/ Dojrr /// y 1 r r i r. / i :r// 11 Name: DiLandro Andrews Engineering Mailing Address: 158 County Rd 39, Suite 10 Southampton, NY 11968 Phone#: 631 259-3959 1 Email:johnl@dilandroandrews.com SO, Name: Robert Amendola RJMD Constriuction LLC k Mailing Address: PO Box 111 Calverton, NY 11933 K M Phone#: 631 624-2137 Email: Ik eEr� rirrr. J,i."ti ¢, ,,,�;J% 4% i/prr,/i; ,li //r // r r r / r�/ r ,..f�// r% r.,ll ,r�,;n„ilf/ Jr/fin , %rrr r/r i j r // �;, r 9 J ,. i�r„r<-'✓ /,rl��i,1+J / iii //f/riir/ ❑New Structure ®Addition ❑Alteration ❑Re air ❑Demolition Estimated Cost of Project: ❑Other $ $320,000.00 Will the lot be re-graded? ❑Yes *No Will excess fill be removed from premises? RYes El No 1 PROPERTY INFORMATION' Existing use of property: residential Intended use of property: residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes ®No IF YES, PROVIDE A COPY. / A e 'R adkn a wvner/can ra urJ+ i rc ias Jor al is respanstb"!e rate d�y�tn ga r d stcarni vraxer f tuba s ►riq d /, 3 van A Ig 0, MAD 4affi e B d7ng Ltepartment far the issu�nee ofw�6D+lr RermitrYdf�b 6�I1�1 zanrt" /r / 0"' n, �/ ✓ / ri r - r , , �� 1 �1 r ff f�b !'Thy( pplica0 agrees o c}r pW with 1l aRi tk a�lle+I ,ar tnanc � �1 � rya a°gad/ gw / ham+ i���Qn pk� a end�nufftlmgrs7,for necessairy inspec�tfairs Pais stteirrents ir�ad herein'are �4� tie� `kaSec`}fa NdwY State Penal Law �,.� Application Submitted By(print name): Laura Rosenberg ❑Authorized Agent ROwner ' Date: ` Signature of Applicant: t a. STATE OF NEW YORK) SS: COUNTY OF S vale Lot 5-11, being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this - anr,- f day of f MOZL, , 20 25 UNota4 Publi TIFFANY__.m._. J C3EF-.EZNY Notary Public-State of New York PROPERTY No.01 BE6284112 Qualified in Suffolk County (Where the applicant is not the owner) My Commission Expires 06/17/2025 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Generated by REScheck-Web Software Compliance Certificate Project 224 Bridge St Energy Code: 2020 NYStretch - 2018 IECC Location: Greenport, New York Construction Type: Single-family Project Type: Addition Project SubType: None Orientation: Bldg. faces 180 deg. from North Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 224 Bridge St Ben Boumnaia Greenport, New York 11944 Dilandro-Andrews Engineering 158 County Rd 39 Southampton, New York 11968 6312593959 benb@dilandroandrews.com Compliance: 4.6%Better Than Code Maximum ILIA: 231 Your UA: 125 Maximum SHGC: 0.40 Your SHGC: 0.40 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Sllab mnn" grade Vrr deollgs are no Ilo ngger consa deired 11in the UA or Iperfouumance o:)m1,,ulll!!ain.e Ipd tl'ii i°iin RES Ira,dll(. each rJab oun..,grade asserrIblly fin the chriinate zone must u'neet:the oamilu,dinwim einE.u°tgy code 6u"7sullation t°g...vahje and atmwlAh n°en'uiwµrmolrel1t:a. Envelo e 5 lies Ceiling:Cathedral Ceiling 736 49.0 0.0 0.022 0.026 16 19 Skylight:Wood Frame 6 0.400 0,500 2 3 SHGC:0.40 Lower Ceiling:Cathedral Ceiling 496 49.0 0.0 0,022 0.026 11 13 Front Wall:Wood Frame, 16" o.c. 200 21.0 4.0 0.045 0.045 7 7 Orientation: Front Small Front 1:Vinyl Frame SHGC: 0.40 6 0.270 0.270 2 2 Orientation: Front Small Front 2:Vinyl Frame SHGC:0.40 6 0.270 0.270 2 2 Orientation: Front Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 1 of10 Double Front:Vinyl Frame SHGC: 0.40 24 0.270 0.270 6 6 Orientation: Front Left Side Wall: Wood Frame, 16"o.c. 265 21.0 4.0 0.045 0.045 10 10 Orientation: Left side Side Double:Vinyl Frame SHGC: 0.40 24 0.270 0.270 6 6 Orientation: Left side Side Single 2:Vinyl Frame SHGC: 0.40 12 0.270 0.270 3 3 Orientation: Left side Side Single 3:Vinyl Frame SHGC: 0.40 12 0.270 0.270 3 3 Orientation: Left side Back Wall:Wood Frame, 16"o.c. 102 21.0 4.0 0.045 0.045 3 3 Orientation: Back Rear Pair:Vinyl Frame SHGC: 0.40 35 0.270 0.270 9 9 Orientation: Back Front Wall 2nd Floor:Wood Frame, 16" o.c. 127 21.0 4.0 0.045 0.045 4 4 Orientation: Front 2nd Floor Single:Vinyl Frame SHGC: 0.40 6 0.270 0.270 2 2 Orientation: Front 2nd Floor Double: Vinyl Frame SHGC: 0.40 24 0,270 0.270 6 6 Orientation: Front Left Side Wall 2nd Floor:Wood Frame, 16" o.c. 163 21.0 4.0 0.045 0.045 7 7 Orientation: Left side 2nd Floor Decorative single:Vinyl Frame SHGC: 0.40 9 0.270 0.270 2 2 Orientation: Left side Back Wall 2nd Floor: Wood Frame, 16"o.c. 35 21.0 4.0 0.045 0.045 1 1 Orientation: Back 2nd Floor Rectangle single:Vinyl Frame SHGC: 0.40 4 0.270 0.270 1 1 Orientation: Back 2nd Floor Rectangle single 2:Vinyl Frame SHGC: 0.40 4 0.270 0.270 1 1 Orientation: Back Floor:All-Wood Joist/Truss 626 30.0 0.0 0.033 0.033 21 21 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2020 NYStretch-2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Paul W. Dilandro - PE 5/28/2025 Name-Title Signature _ Date Project Notes: 2020 NYStretch code in climate 4 R-21 Cavity Insulation is minimum on Exterior Wall Assemblies The Code is PRESCRIPTIVELY MET with an R-21 Cavity wall however, Rescheck implemented A U-Value of.045, which requires a much higher R-Value. Dilandro Andrews Engineering has contacted Rescheck regarding this discrepancy on 05/31/2023.The Rescheck help desk stated that while this discrepancy has been noted, the correction has not been made. Within this completed and passing Rescheck, the exterior wall is shown to have R-21 cavity and R-4 continuous. The R-4 continuous insulation is required to yield a PASSING score on Rescheck but will NOT be installed Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 2 of10 REScheck Software Version - REScheck-Web Inspection Checklist Energy Code: 2020 NYStretch - 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified - nspection/Plan Review Value Value Complies Comments/Assumptions # Pre-1 & Re ID 103.1, Construction �� .o„.�„�... ,.,�. _e�,.... � ,.,�.�..,.�.�_ e..,.�..I_.......�.._........� ......:_..�.�. ction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PRl]1 energy code compliance for the building envelope.Thermal ❑Not Observable ❑Not Applicable envelope represented on construction documents. 103.1, :Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment isis�Heating: Heating: ❑Complies ..._.. _. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling, ❑Not Observable y110 Manual J or other methods Btu in Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: ........ _ �..... _.._--___. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 3 of10 L M Section # Foundation Inspection Complies? Comments/Assumptions & Re A�, _ Pprotective 303.2.1 AA e covering is installed to ® .. :...g..:.. '. Complies. ... [.FOJI)2 'protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑Not Observable grade. ❑Not Applicable 403. m controls Snow-and ice-melting system E mm mplies'❑Complies [F 1212 installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: - ... 1 High Impact(Tier l) 2 Medium Impact(Tier 2) `Low Impact(Tier 3) Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 4 of10 Section .. mmPmmlamITITnITITm mmmmmmmIT Verified r Field # Framing/Rough-in InsPgction Value Value Complies? Comments/Assumptions m W Re� ID 02,11, Glazing U-factor(area-weighted U- U- ❑Complies See the Assemblies 402.3.1, average). ❑Does Not table m 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable g� 303.1.3 U-factors of fenestrationprod �..,.... ..._...___._. ....... ._._.� _............._ . ucts ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ; taken from the default table. ❑Not Observable ❑Not Applicable 402.1.1, Skylight U-factor. - �❑DoepNot ,table for or. U- U ❑Com Iles See the En .. Envelope Assemblies values. 402.3.6, ❑ 402.5 Not Observable [FR5]1 ❑Not Applicable 402.4.1.1 Air barrier and p .._. thermal barrier ❑Com lies [FR23]1 installed per manufacturer's ❑Does Not instructions.An approved third party will inspect all components ❑Not Observable and verify compliance. See ❑Not Applicable section details and guidance from Table 11402.4.1.1. 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/l.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Compli Wmm li .. .... es ..�..... [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate:52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Appllcable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ! ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 'for< 3 inches in diameter. _ ....._..........._. _.,...... ------- ........ _.- 403.3.2 Ducts, air handlers and filter ❑Complies [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or ❑Not Observable International Residential Code, as ❑Not Applicable applicable. 403.3 Duct system in new buildings and w.., ❑Complies .... �_........ [FI32]1 additions are located in a ❑Does Not conditioned space in accordance with Sections R403.3.7 (1-2). ❑Not Observable ❑Not Applicable 403.3.8 Ducts are sized in accordance ❑Complies [FI33]1 with ACCA Manual D and sections ❑Does Not R403.7-8. ❑Not Observable ❑Not Applicable 403.3.5 ,m_B._ n..o.o.�,. ��.a�,........�_��.. .�.w .... .......... .m �..._. .. ..._... _ ... ........� uilding cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable g p er 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) 1 Hi h Im act(T�. .. ..._ _.._ .. .�._._.... ......___ Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 5 of10 Sec, ion 1 1 111­­11111_IL--.....­­....PlansValue Value Field Verified �..... .a ......._... 11 & Re ID . Framing Rough-in Inspection Complies. Comments/Assumptions 403.3.7 Ducts declared to be within the ❑Complies [FR28]3 conditioned space are either 1) ❑Does Not completely within the continuous air barrier and within the building ❑Not Observable thermal envelope, 2) buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3,6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is<= 1.5 cfm/100 square feet of conditioned floor area served by the duct system,or 3)the ceiling insulation R-value installed against and above the insulated duct>=to the proposed ceiling insulation R-value, less the R- value of the insulation on the �... 403.4 HVAC piping conveying fluids R- R ❑Complies [FR17]2 above 105 4F or chilled fluids ❑Does Not below 55°F are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water are insulated to R- i es � .....�. ._._,e �� ��_r .... .. ._............._. pip R ❑Complies [FR18]2 >_R-3. j❑Does Not ❑Not Observable ❑Not Applicable 03.5 Energy conservation measures R- R- ❑Complies [FR29]2 for SWH systems follow ❑Does Not guidelines in section R403.5.1-5. ❑Not Observable !❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: HI C h Im a ct(Tier 1) 2 Medium Impact(Tier 2)i�.. .�W _p _._........ ....._._...-h p 3 1 Low Impact(Tier 3.�... ._. Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 6 of10 # Insulation Inspection Value Complies?Section Plans Verified Feld Verified Value ' Comments/Assumptions & ReecID. ..... .. ... .,._ .... _,,, . _ .... .._ _..... .... yes. Comm.. .. 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not kd provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.E ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable ❑Not Applicable . .. ...... . _ ,.._.__�_,_.. . ....-a�.. .. ..._ 303.2, Floor insulation installed per ❑Complies 402.2.8 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the ❑Not Observable "0 underside of the subfloor, or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/1 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 :wall insulation on the wall mass ❑ Mass ❑Not Observable [IN3]1 ;exterior,the exterior insulation ;requirement applies(FR10). ❑ Steel ❑ Steel j❑Not Applicable ........W.. .. .. �..�.., _._........_ ..._ ._ ....._ 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medi p _pa- r r� Low Imot(Tie Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 7 of10 Section �.n _ _ # al inspection Provisions Plans Va.erified Field Verified & Re ID p Value Complies? Comments/Assumptions 402.1.1, Ceilin g in R-value. R ❑Does 402.2.1, Wood ❑Complies t table for Envelope valu Assemblies 402.2.2, ❑ Wood P blies .. 402.2.6 Not ❑ Steel Steel [FI1]l []Not Observable ❑Not Applicable 303.2manufacturer's instructions.p — iie s 3031.1„1, Ceiling insulation installed am - p _ ..... [F1211 Blown insulation marked every E]Does Not i90 ftz, ❑Not Observable [02.2].3 insulation include baffle— No ppesicable Vented attics with air permeable ,..—...Does Not .. ... �.... _I to soffit and eave vents that cent extends over insulation. []Not Observable EJN[ .Attic ❑Court Applicable 02 2.4 insulation > ._. _._ i Attic access hatch and door �— R- p es F131 _R-value of the R _ . . ., .._ . .. : �.: " adjacent assembly. ❑Does Not ❑Not Observable [FI17 .1.2m.:achw.. ❑Not Applicable l In Climate Zones0- ._.. .. ❑ 'om Pies test @ Pa <-5 ACH 50 = 1 —,.ACH 50 .Ap _ -...�._ 2, and <=3 ach in Climate Zones 3-8. ❑Does Not ❑No t Observable .-......-. .....m� �_..�..� _ t Applicable 403.3.3 Ducts are pressure tested to ❑N.... cf . ., ... [FI27] :determine air leakage with ftz cfm/100 ftz ❑Does Not cfm/I00 [�Cr� mpGme .._�m�� �._......�...� either: Rough-in test:Total leakage measured with a '❑Not Observable pressure differential of 0.1 inch w.g.across the system including ❑Not Applicable :the manufacturer's air handier enclosure if installed at time of test, Pdstconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air _ handler enclosure. 403,3 4 Dm�10g4 nesstesacrosst re system of ftz cfm/10 0 ....�..�._.,�:0_.�� oes No�.�. cfm/1 Complies _—._ _. ..... <=3 cfm/100 ft2 without air ftz ❑D t handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable ur handier leakage designatedon. 403.3i2 1 Air cha during. .. _ ] b manufacturer at .� rug Framing lnspcti [F124 ❑Complres y =2%of design air flow. ❑Does Not _ ❑Not Observable ❑Not Applicable _._.m..._ Complies [Flg] rammable thermostats primary I for control of Does Not heating and cooling systems and Initially set by manufacturer to ❑Not Observable codespecifications. ❑Not Applicable 40� pump thermostat 2 Heat um _ a :.. nm tat installed '� '� " •-----•- - [FI10 z on heat pumps. ❑Oomplmes �._.._. —...,._ []Does Not ❑Not Observable _.. .. — ❑Not Applicable 403.5.1 Circulating service hot water [FI11]2 systems have automatic or ❑Complies accessible manual controls, ❑Does Not ❑Not Observable _h ❑Not Applicable 1.H m pim I act Tier I) 2TMedium Impact(Tier 2) _.... 3 Low lm µact W u 9 Project Title: 224 Bridge St p (Tier 3)� Data filename: Report date: 05/28/25 Page 8 of10 Section P Value Value lanified m Feel Verified # Final Inspection Provision � Complies., Comments/Assumptions & Rec ID __ .. _._..... mm . .... J..m._., . _ ....._......_......... 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable ❑ R403.6.1. Not Applicable 403.2 Hot water boilers supplying heat []Complies [F]26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water [:]Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 m.. .Electric heat traces stems DComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the [:]Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. . . ............... :.. „.,. .. , ..m.,. .._... ._.._. ........ 403.5.2 Demand recirculation water ❑Complies [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the []Not Observable water entering the cold water ❑Not Applicable piping to <= 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 have >=40 percent efficiency if ❑Does Not installed for equal flow or>=52 percent efficiency if installed for ❑Not Observable unequal flow.Vertical drain water ❑Not Applicable heat recovery units comply with CSA 1355.2 and tested and labeled in accordance with CSA 655.1. Potable water-side pressure loss of drain water heat recovery units are < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units are < 2 psi for individual units connected to three or more showers. . . ... ..�_.m.... --- .... 404.1 90%or more of permanent ❑Complies [FI6]1 fixtures have lamps with an ❑Does Not efficacy>= 65 lumans/watt or have a total luminaire efficacy ❑Not Observable >=45 lumens/watt. ❑Not Applicable 403.2 ..-Deta hedand andt o-fa....__........._ _ �..,,. nd two-family ❑Complies 1 g ouses where ❑Does Not the conditioned space is > 1,400 sf comply with the requirements ❑Not Observable of Appendix RA. ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact Tier 2) 3 L w ... - _. p ( ow Impact(Tier 3) Project Title: 224 Bridge St Report date: 05/28/25 Data filename: Page 9 of10 Section alIns pection Provls�ons Plans s Value fled Field Verified & Re iC7 Value Complies? Comments/Assumptions g ... One or two- 404 3 _ _... family dwellings end �..._.. . [FI36 1 "�° ] townhouses with parking area � Ompli s provided on the building site shall hDoes Not ` have a 20812.40V 40�amp outlet for each dwelling unit or panel ❑Not Observable capacity and conduit for the ❑Not Applicable future installation Of such an outlet, See sectaon details, _ 404.1.1 Fuel gas lighting systems have FI23 a o....���,. mm...�� .., ] no continuous pilot light, f7Complies 7...�.. k10 ®floes Not [FI ❑Not Observable 401.3 Compliance certificateposted. """'" ,_[]Not Applicable ®Complies . ._�..�. FI'Does Not __ ❑Not Observable 303.3 Manufacturer manuals for �' ❑Not Applicable __ [FI18]3 mechanical and water heating ❑goes Note � systems have been provided. ❑Not Observable Additional Comments/Assumptions. Not Applicable llllglr Impact(Tier 1) 2 Medium Im ) 3 Low Iµ Project Title: 224 Bridge St -� -••• •m- Data filename: Report date: 05/28/25 Page 10 of10 m Efficiency, li MMOM Above-Grade Wall MMMMMMM 25.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Window 0.27 %40 Door Skylight 0.40 0.40 MMM Heating System- Cooling System: Water Heater: Name: Date: Comments