Loading...
HomeMy WebLinkAbout52307-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52307 Date: 10/01/2025 Permission is hereby granted to: 920 Cedar Point LLC 15 Middle Dr Plandome, NY 11030 To: Construct first and second story additions and alterations to an existing single-family dwelling to include an FIVAC system, decks, raised porches and outdoor shower as applied for per DEC, Trustees and SCHD approvals. Premises Located at: 920 Cedar Point Dr E, Southold, NY 11971 SCTM#90.-2-19 Pursuant to application dated 06/24/2025 and approved by the Building Inspector. To expire on 10/01/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition &Alteration CO Single Family Dwelling-Addition/Alteration $$100.00 100.00 Total 2 466.00 Building Inspector rcrarNp TOWN OF SOUTHOLD—BUILDING ILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971 0959 Telephone 631 765-1802 Fax (631) 765-95021ttrwouatltolltcvt o IF APPLICATION FOR BUILDING PERMIT Date Received For Office Use Only G.. PER NO. J O I Building Inspector: JUN 2 4 202 Applications and forms must be filled out in their entirety. y Incomplete ap plications will PP II not be accepted. Where the Applicant Owners Authorization form(Page 2)shall be completed.not the owner,an Teg ,,,n part �l n of Date: 4hift ::::A I I OWNER(S) PRO RTY: Name:920 Cedar Point LLC (Kenneth McCulloch) SCTM#1000-90-02-19 Project Address:920 Cedar Point Drive East, Southold NY Phone#:212-355-4704 Email:mcculloch98@gmaii.com Mailing Address:1 5Middle Drive, Plandome NY 11030 CONTACT PERSON: Name:Michael Macrina Architect P.0 Mailing Address: 97L Main Street, Stony Brook NY Phone#:6316866585 Emai,I:MMacrina@mmarchitectaia.com DESIGN PROFESSIONAL INFORMATION; Name:Michael Macrina Architect P.0 Mailing Address:971- Main Street, Stony Brook NY 11790 Phone#:6316866585 Email: mmacrina a@mmarchitectaia.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure WAddition Witeration ❑Repair ❑Demolition ❑Other Estimated Cost of Project: Will the lot be re-graded? ❑Yes igNo Will excess fill be removed from premises? ❑Yes *No 1 PROPERTY INFORMATION Existing use of property: ,1 Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants d restrictions Tls with respect to this property? ❑Yes No p p y• ert a IF YES, PROVIDE A COPY, R Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the 1"owvn Code. APPLICATION IS HEREBY MADE to the isuild'i'ng Department for the issuance of a building permit pursuant to the Building Zone Ordinance of the Town of.Southold,Suffolk,County,New York and other applicable Lawns,Ordinances orfteguiations„for the construction of buildings, additions,alterations or for removal or demolition as herein described,The applicant agrees to comply with all applicable taws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildingisp for necessary,inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State penal Lava. el Macrina Architect P.0 y(print nafT1 Authorized Agent Dow ner Application Submitted B MICha Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF J-4 " F z being duly sworn, deposes and says that(s)he is the applicant (Name of individual lsiigning contract)above narn d, (S)he is the U`Th ( ('Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in ion file therewith. Sworn before me this y of 120 Notary Public t PROPS o S Pp NOTARY i i„Nisi it S i"�4l f OF'rwl:yar oxK Regkinalion No, 61 (Where the applicant is not the owner) Quiih rcxl mmm ap,piii4k e'N wjmfr Coll mtrksi(mi 1'xpmrkw 17 ktarch"'4i,T6 residing at � ,, do hereby authorize �� �� to apply on my b al the Town of Southold Building Department for approval as described herein Owner s Signature Date .a- ai4 Print Owner's Name 2 r r � ro BOARD OF SOUTHOLD TOWN TRUSTEES SOUTHOLD,NEW YORK PERMIT NO. 10767 DATE: APRIL 16,2025 ISSUED TO: 920 CEDAR,POINT L PROPERTY ADDRESS: 920 CEDAR POINT DRIVE EAST SOUTHOLD SCTM# 1000-90-2-19 AUTHORIZATION Pursuant to the provisions of Chapter 275 of the Torn.Code of the Town of'Southold and in ° accordance with the Resolution of the Board of Trustees adopted at the meeting hold on A ril I 2 2 ,and in consideration of application fee in the sum of l 50,00 paid by N sear "c int,.l l and subject to the Terms and Conditions as stated in the Resolution,the Southold Town Board of Trustees authorizes and permits the fallowing: Wetland Permit to construct an ll0?sq.ft.second-floor addition over part of one-story portion of existing 3,338sq.ft. I &2 story dwelling with attached garage to remain; construct on landward side of'dwelling a 336sq1t,.two-story addition(partially in place of existing 90sq.fl.stoop with arbor to be removed); 288sq.ft.front porch addition,and 350sq»ft,grade-level masonry entry patio/walkway; install a 6'x7'outdoor shower(piped to drywell) construct on west side of dwelling a 51x8'landing,with steps and 200sq.fit. grade-level masonry patio; remove existing conventional septic system and install a new I/A sanitary system;install storm-water drainage system;and to establish and perpetually maintain area betweer;top of bank and bulkhead (excluding existing fVx68'deck),as a vegetated non-turf buffer; and to establish and perpetually maintain a 61-20'wide(10"'average,2,000 sq.ft.)•non turf buffer along the top of bank; with the condition to install gutters,to leaders,to dryive�ls;if the proposed becomes deemed a demo(per Town Code),this permit is void and any work thereafter will require a new permit; all as i lep cted on the site plan prepared by Michael Macrinal,,received on May 5, 2025,and stamped apprved on May 5,2025. IN WITNESS WHEREOF,the said Board of Trustees heresy cinses ita Corporate Seal to be affixed, and these presents to be subscribed by a majority of the said Board as of the day and year written above. __ � ..., ' 01 � s it oI)L Absent A - - t . . TERMS AND CONDITIONS The Permittee 920 Cedar Point- 1.1,r (),)A Cedar Iloint-Qrive East Southold New York as part of the consideration for the issuance of the Permit does understand and prescribe to the following: That the said Board of Trustees and the Town of Southold are released from any and all damages,or claims for damages,of suits arising directly or indirectly as a result ofany operation performed pursuant to this permit,and the said Permittee will,at his or her own expense, defend any and all such suits,initiated by third parties, and the said Permittee assumes full liability with respect thereto,to the complete exclusion of the Board of Trustees of the Town of Southold. 1 That this Permit is valid for a period of 36 months,which is considered to be the estimated time required to complete the work involved, but should circumstances warrant, request for an extension may be made to the Board at a later date. 3 That this Permit should be retained indefinitely,or as long as the said Permittee wishes to maintain the structure or project involved,to provide evidence to anyone concerned that authorization was originally obtained. 4. That the work involved will be subject to the inspection and approval of the Board or its agents,and non-compliance with the provisions of the originating application may be cause for revocation of this Permit by resolution of the said Board. 5. That there will be no unreasonable interference with navigation as a result of the work herein authorized. 6. That there shall be no interference with the right of the public to pass and repass along the beach between high and low water marks, 7. That if future operations of the Town of Southold require the removal and/or alterations in the location of the work herein authorized,or if, in the opinion of the Board of Trustees,the work shall cause unreasonable obstruction to free navigation,the said Permittee will be required, upon due notice,to remove or alter this work project herein stated without expenses to the Town of Southold. 8. The Permittee is required to provide evidence that a copy of this Trustee permit has been recorded with the Suffolk County Clerk's Office as a notice covenant and deed restriction to the deed of the subject parcel. Such evidence shall be provided within ninety(90)calendar days of issuance of this permit. 9. That the said Board will be notified by the Permittee of the completion of the work authorized, 10. That the Permittee will obtain all other permits and consents that may be required supplemental to this permit,which may be subject to revoke upon failure to obtain same. IL No right to trespass or interfere with riparian rights. This permit does not convey to the pertnittee any right to trespass upon the lands or interfere with the riparian rights of others in order to pet-form the permitted work nor does it authorize the impairment of any rights,title, or interest in real or personal property held or vested in a person not a party to the permit. New York State Department of Environmental Conservation Division of Environmental Permits, Region One Building 40- SUNY, Stony Brook, New York 11790-2356 1211111111110 Phone: (631)444-0365 • FAX: (631)444-0360 Website: www.dec.state.ny.us Erin M.Crotty Commissioner LETTER OF NON JURISDICTION,-TIDAL WETLANDS John J. Reardon August 14, 2002 30 Wilton Road Cold Spring Harbor, NY 11724 Re: Application #1-4738-03048/00001 Reardon Property, 920 Cedar Point Drive East, Southold, NY Dear Mr. Reardon: Based on the information you have submitted, this Department has determined that: The property landward of the 10' elevation contour as shown on the survey prepared by John T. Metzger on April 22, 2002 is beyond the jurisdiction of Article 25 (Tidal Wetlands Act). Therefore, in accordance with the current Tidal Wetlands Regulations (6NYCRR Part 661) no permit is required. Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies. Very truly yours, Mark C. Carrara Permit Administrator cc: Charles Thomas BMHP file Albert J. Krupski, Jr. STO>RMWA ]ER SUPERVISOR MANAG IEMIENT SOUTHOLD TOWN HALL-P.O.Box 1179 � 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town Of Southold C TER 236 STORMWATER MANAGEMENT REFERRAL FOR . .. �� { ee e. ( APPLICANT INFORMATION TO �.....—.. BE COMPLETED BY THE APPLICANT r. ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) . _ _ .� _ —.. ..... _ _ _ —.. _ _ — � � _ � _ _ _ � APPLICANT: (Property Owner� eisi,ggn Professioonna gent, Contractor, Other) NAME: ✓ Date: IX 1 Contact Information: o (E-Mail 8 Telephone Number) E Property Address / Location of Construction Site: S.C.T.M. #: 1000 District i Section Block Lot COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT s � TO BE COM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - h' Area of Disturbance is less than 1 Acre. No S.P.D.E S,Permit is M11ired_'I_ �� ❑ - Project does Not Discharge to Waters of the State. No S.P.D.E.S. Permit is Required! ❑ - Area of Disturbance is Greater than 1 Acre&Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit i DIRECTLY From N.Y.S. D.E.C. Prior to Issuance of a Buildin Permit. '� ❑ - Area of Disturbance is Greater than I Acre&Storm-water Runoff Flows Through Southold Town's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town E� inr�i De artment Prior to Issuance of a Building Permit. �I Reviewed By: ,�"���� Date: FORM # SMCP-TOS December 2024 ,�- 1 Town Hall Annex � � Telephone(631)765-1802 54375 Main Road , Fax(631)765-9502 P.O. Box 1179 Southold, NY 11971-0959 BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE C+ONSTRUCTI+ON PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date Owner: C C uI f ech Location of Property: a 61 "-r Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roof ming (FR) Signature: L= Name (person sub " ,Y this form): .gip Capacity(check applicable line): Owner Owner representative TrussReg15.docx Effective 1/1/2015 Generated by REScheck-Web Software Compliance Certificate Project McCulloch Energy Code: 2028 IECC Location: Southold, New York Construction Type: Single-family Project Type: Addition Project SubType: None Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 920 Cedar Point Drive East Ken and Liz McCulloch Michael Macrina Architect p.c. Southold, NY 920 Cedar Point Drive East 97 Main Street Suite L Southold, NY 11952 Stony brook, NY 11790 Compliance: 13.4%Better Than Code Maximum UA: 283 Your UA: 245 Maximum SHGC: 0.40 Your SHGC: 0.26 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Sllab one giu�wde tradeoffs are no longer considered in the i o performance cc,uisu,gklae e path in Pl::�rci eck slab on-grade p .,, l".e�.Pl a sernbly in the speciffied clilmate zone must meet the ni6nun°ronu°n energy code Msuulatioe R Value and depth uegu.uir miu nts. Ceiling: Cathedral Ceiling 1,747 42.0 0.0 0.025 0.026 44 45 Wall:Wood Frame, 16"D.C. 1,773 27.0 0.0 0.051 0.060 76 90 Door: Glass Door(over 50%glazing) 125 0.300 0.320 38 40 SHGC: 0.26 Casement Window:Wood Frame 54 0.280 0.320 15 17 SHGC: 0.23 Double Hung Window: Wood Frame 102 0.300 0.320 31 33 SHGC: 0.27 Floor:All-Wood joistfFruss 1,240 30.0 0.0 0.033 0.047 41 58 Project Title: McCulloch Report date: 06/23/25 Data filename: Page 1 of10 Compliance Statement. The proposed building design described here is consistent with the inking plans,specifications, an the calculations submitted with the permit application.The proposed b keghsbendegne to met the 2011ECcrequirements in REShc Version : REshekmA and b comply with the mandatory'm eme%Imeh¥e�shcIRpmAcebs \/�\\��\ « » ° \\ � . . ¥ \ / \\% 2?\ \. Date Name-st@ \ \y\ 71 Project Title: McCulloch Report date: 06/2+25 Data filename: Page 2 0 l0 RE,Scheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions 03.1, IID Construction ❑CoW 103.1 �d drawings and mplies documentation demonstrate =❑Does Not [PR111 :energy code compliance for the building envelope.Thermal -]Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and "" ❑Complies 103.2, documentation demonstrate % ❑Does Not 403.7 energy code compliance for ❑Not Observable „ R311 lighting and mechanical systems. Systems serving multiple ❑Not Applicable dwelling units must demonstrate - ;compliance with the IECC = Commercial Provisions. 302,1, Heating and cooling equipment is Heating: Heating. ,❑Complies a 403,7 sized per ACCA Manual S based Btu/hr Btu/hr �❑Does Not (PR212 on loads calculated per ACCA Cooling: Cooling: UNot Observable A-0 Manual J or other methods Btu/hr Btu/hr 'approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 3 of10 Lion e 'Ouindation lnspectionu Compt es"i I . Co mentslAsui'smptions ,......µ ....,...- �.�,�.....d.�..._...., � ..m...-.-».-...,.,.W._....�._._.._ � �,,..-_w_.... 30121 1 protective covering is Installed to ❑Complies [VO1112 protect exposed exterior insulation ,❑Does Not and extends a minimum of 6 in.below []Not Observable grade. ❑Not Applicable 4t13.g; Snow-and ice-melting system controls ❑Complies fFO1 j'2 installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: g P p _ Low Impact(Tier 3) 1 Hi h Im act(Tier 1) 2 1 Medium Im act(Tier 2) 3 Project Title: McCulloch Report date: 06/23/25 Data filename: Page 4 of10 Section Ptans Verified Field Verified # Framing / Rough-in Inspection Value Value Complies? Comments/Assumptions 021.1, GlazingU-factor( _ ,❑Does Not W mm j table for value e Assembliesm avers (area-weighted U- U- ❑Com lies op 402.3.1, average). s. 402.3.3, ❑Not Observable ;402.5 '❑Not Applicable [FR2]i41 P a ❑ 303.1.3 U-factors of fenestration products Complies , P [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable ;taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ' �„ ;❑ConnPlies [FR23]1 installed per manufacturer's '/ ❑Does Not instructions. ❑Not Observable %❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting % ❑Does Not AAMA/ DMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC ❑Not Applicable ; 400 that do not exceed code limits. .. a������ /„,. ` i/i� iii 402.4.5 IC-rated recessed lighting fixtures „ / ❑Complies [FR16]2 sealed at housing/interior finish '0Does Not �i and labeled to indicate <_2.0 cfm ' ��� „ , ❑Not Observable leakage at 75 Pa. / Not Applicable i r 40 ` ❑Com lies 3.3.1 1 Supply and return ducts in attics P [FR12]1 'insulated >= R-8 where duct is ,,,/o,, o` %"❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches.Supply and ❑Not Observable return ducts in other portions of ;❑Not Applicable the building insulated >= R-6 for , j, diameter>= 3 inches and R-4.2 /i /// %%% a „ % i %° i/ ,for< 3 inches in diameter. % 403.3.2 'Ducts, air handlers and filter Complies [FR1311 'boxes are sealed with Not ,joints/seams compliant with „ ❑Not Observable International Mechanical Code or International Residential Code, as ❑Not A licable PP 403.3.5 applicable Building cavities are not used as ❑Complies [FR15]3 'ducts or plenums. i/� „ ,,,,,i -❑Does Not ❑Not Observable q ❑Not Applicable 3.4 :HVAC piping conveying fluids R- R- ❑Complies [FR17]2 'above 105 °F or chilled fluids ❑Does Not below 55 4F are insulated to>_R- ❑Not Observable 3. i ;❑Not Applicable . 4 0.4.1 Protection of insulation on HVAC / ❑Complies 411 'piping. i ,, ❑Doe s Not ❑Not Observable �/❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R ❑Complies [FR18]2 >_R-3. ❑Does Not !❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are �/� ❑Complies [FR19]2 installed on all outdoor air /�"O '/'� ElDoes Not intakes and exhausts. / % � l❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 6 of10 Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Oarnrbents,/Asuptioes fke IIa _ .—� , � .._ All installed msulat ....,�.. ...ion is labeled �. 303. Complies ; [IN13;] or the installed R-values ❑Does Not provided. ❑Not Observable <C�Not Applicable 402.1.1, ;Floor insulation R-value. R- R C7COmplies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ti❑Does Not ;table for values. [IN1]1 ❑ Steel ❑ Steel tlNot Observable ❑Not Applicable 303.2, Floor insulation installed per ;❑Complies 402.2.8manufacturer's instructions and 7Obs Not 2]1 in substantial contact with the N ❑Not Observable p underside of the subfloor, or floor " ❑Not Applicable framing cavity insulation is in contact with the top side of }sheathing, or continuous ' insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.5 masll s walinsull w th at least lI thisof is a ❑ Wood ,Nm❑ Wood ❑Do Not ±See the Envelope Assemblies table for values. 402.2.E wall insulation on the wall ❑ Mass `❑ Mass tNot Observable [IN3]1 1exterior,the exterior insulation m ;requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 ,Wall insulation is installed per Zkomplies ; [IN4]1 manufacturer's instructions. ; ' ❑Does Not r ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 7 of10 Section Plans Verified Field Verified & Re ID _.Ceiling insulation R value. R_ . .�. _.� _ — R Value Value. . .. ❑Commie _ m-....,... p �tions � # Final Inspection Provisions p plies Comments/Assumptions 402.1.1, s See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 ❑Not Applicable [FIll1 303.1.1.1, Ceiling insulation installed per "�, " , ' ]Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 j Blown insulation marked every %! `❑Not Observable 300 ft2. ❑Not Applicable 402.2 �,.,. .3 .Vented attics with air permeable � r � ; ,❑Complies [FI22]2 insulation include baffle adjacent -%,❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ; ❑Not Applicable ,........._�. ......._ I402.2.4 Attic access hatch and door R R- ;❑Complies [FI3]1 insulation >_R-value of the y❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Cormplies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not %<=3 ach in Climate Zones 3-8. j❑Not Observable ❑Not Applicable 403.3.3 ,'Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 ',determine air leakage with ft2 s ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable ;leakage measured with a ;pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler ;enclosure if installed at time of ,test. Postconstruction test:Total Eleakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handier enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air j❑Not Observable handier @ 25 Pa. For rough-in ❑Not Applicable tests,verification may need to occur during Framing Inspection, �., 403.3.2.1 ;Air handler leakage designated ❑ orrlplies " [FI24]1 by manufacturer at<=2%of ❑Does Not ,design airflow. "' ''' ` ❑Not Observable r ❑Not Applicable 403.1.1 Programmable thermostats "ECornplies [FI9]� installed for control of primary ' �, ��/ ,,, ��/�� ❑Does Not heating and cooling systems and ' ""' initially set by manufacturer to �°❑Not Observable _ ❑Not Applicable rcodespecifications. 1.2 Heat pump thermostat installed ,,,',',,,❑`Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable r .. 401.5.1 Circulating water �[ systems automaticor El Does Not accesblemanuacontrols. ,,,❑Not Observable ❑Not Applicable a 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions 036.1I� All mechanical... .. .w m .__.. & w q' e, _ , ventilation system , '❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable❑ R403.6.1. Not Applicable 403.2 Hot water boilers supplying heat %❑Complies [F126]� through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable 2 E ,temperature. 403.5.1.1 Heated water circulation systems I ❑Complies [FI28]2 'have a circulation pump.The ;❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply' "~ r F pipe.Gravity and thermos- r❑Not Applicable ;syphon circulation systems are not present. Controls for circulating hot water system r pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump ` when water is in circulation loop IS at set-point temperature and no demand for hot water exists. , °❑Com 403.5.1.2 :Electric heat trace systems " plies [FI29]2 comply with IEEE 515.1 or UL , ; „' '" ❑Does Not 515. Controls automatically - ,,adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable A l' desired water temperature in the piping. 403.5.2 Demand recirculation water „iiiii�/ii��"';' ����� ����� .❑Complies [FI30]� systems have controls that � � �; ❑Does Not manage operation of the pump " ❑Not Observable and limit the temperature of the water entering the cold water ❑Not Applicable ...nnn..aa� i Nn to <= 104°F 403.5.4 Drain water heat recovery units �„ �DConriplies [FI31]2 tested in accordance with CSA " El Not 655.1. Potable water-side ;❑Not Observable pressure loss of drain water heat i s❑Not Applicable individual units connected to one % , or two showers. Potable water- i ;side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 ;90%or more of permanent ,❑Complies [F16]1 fixtures have high efficacy lamps ❑Does Not Pii �° �i%%% riii��i� ❑NOt Observable ` :f❑Not Applicable ❑Complies [04.1.1 Fuel gas lighting systems have 4 123]3 no continuous pilot light. ° „ El Does Not b ❑Not Observable " %❑Not Applicable 401.3 ;Compliance certificate posted. " ❑Complies [F17]2 El Does Not %❑Not Observable ,, '°❑Not Applicable 1 lHigh Impact(Tier 1) 2 Medium Impact(Tier 2) J 3 Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 9 of10 Section Plans Verified Field Verified 'Final Inspection Provisions Value Value p oms� p lac R l� ..._..._._.....�_...�. —....._. .. � ._ Complies? 0oments� �ssu tio�u 303„3 Manufacturer manuals for ®Complies (FI1813 mechanical and water heating ;CJDoes Not systems have been provided. '" y ;[:]Not Observable' � ' � � ��Ohiot Apfrlicable j Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 'Medium'Impaci(Tier ) 3 Low Impact(Tier 3) Project Title: McCulloch Report date: 06/23/25 Data filename: Page 10 of10 / 2018 IECC Energy 0 Efficiency Certificate MMMMMMMM Above-Grade Wall 27.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 42.00 Ductwork (unconditioned spaces): OMMMMMMM=' Window 0.30 0.27 Door 0.30 0.26 MMMMM= Heating System• Cooling System: Water Heater: Name: Date: Comments C s �sSTAR NORTH 16 so,. E OINT DRIV . � 1Do.a7 E EAST S 83.26100 E 100 2 EXIST.ELECTRIC SERVICE TO REMAIN 50%EXPANSION SITE AREA .zc\\ \� p \'01- PROP.100X940 4 � � R 0 ,,., DEPTH LEACHING d47 4,. PROP,WATER 1.80• ®� POOL(TYP.OF 2) '` LINE VICINITY MAP . 1000 / ° SCALE. :1"=1,000' m SCALE:1"=1000' } (IMPROVE f0 II PUBLIC WATER) a \�L A�I-AOF -TU EXIST.=ATERLINE 3 SITE INFORMATION f TO BE ABANDONED PROP.FUJI CLAN M t - "` EXIST.BURIED OIL - ( SITE: 920 CEDAR POINT DRIVE EAST TREATMENT UNIT- N - �� , MODEL CEN 10 TANK TO BE RMOVED SOUTHOLD,NY 11971 PROP.FUJI CLEAN - f1) - r _ SCTM M 1000-90-2-19 t PROP.DRYWELL FOR GROSS LOT AREA: 4B 498.5 SF(1.113 ACRES) COODENHANELON + �c cRnvEi OUTDOOR SHOWER WOODEN H-FRAME POST30 �, I orsmEµ.Ay _ [) �� � SUBDIVISION: MAP OF CEDAR BEACH PARK EXIST.CESSPOOL-- r g � �_ 7 FILE NO.90,FILED DECEMBER 20,1927 rof TO SE ABANDONED , ; per, I pA „ -.rO .. AND REMOVED i SANITARY SYSTEM CALCULATIONS ( PRi3P,OUTDOOR SHOWER ;j 0 a SINGLE FAMILY DWELLING ', --EXl�s?.BURIED PROPANE _ Pt �`�`' '= TANK TO REMAIN 2r _ EIGHT(B)BEDROOM-SINGLE FAMILY DWELLING=890 GPD € g G. f sCTMN:100a9a2-20 ftROOAIIA OWfS DESIGN t j( US - [[ (IMPROVED W/PUBLIC WATER) Op 1 . r REQUIRED: EIGHT(B)BEDROOMS=860 GALLON SYSTEM PROPOSED: ONE(1)FUJI CLEAN UNIT,MODEL CEN10(1,000 GPD) N 18 to 1 _ 3 SANITARY LEACHING FIELD DESIGN 0J '-.� - '_'�- `t-� REQUIRED: 550 SF OF SIDEWALL AREA ( PROPOSED: NEW LEACHING POOLS - 10,DIA.LEACHING POOL HAS 31.4 SF PER LF 550 SF/31.4 SFA-F=17.5 LF REQUIRED PROVIDE: TWO(2)1O'DIA.BY 9'EFF.DEPTH LEACHING POOLS N WE �°77A'` EAST arBteaia.AR sse '2 Q as TS/WN D 71 z SCDHS r . R O SANITARY H a DESIGN XCG N t3 - �`F SUFFOLK COUNTY DEPARTMENT OFHEALTH SERVICES Eck PERMIT FORAPPROVAL OF CONSTRUCTION FOR A ( Abandonment of the existing sanitary system m , in " I conformance With the Department's requirements. SINGLE FAMILY RESIDENCE ONLY OVERALL Submit completed form VVul'M-080 as proof SITE PLAN 519I2025 R-25 0638 BASE MAP: OVERALL SITE PLAN DATE— Ed.S. E Via. SITE PLAN OBTAINED FROM: C- - "= 100 METES AND BOUNDS SURVEYING SCALE:1 40' APPROVEDV _ DATED:SEPTEMBER 23,2024 0 40 00SEE 4 - --.- T FOR MAXIMUM 8 ----r BEDROOMS 1 4 SCALE:1"=40' EXPIRES THREE YEARS FROM DATE OF APPROVAL MMAzso3