Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
49586-Z
�o"of so�ryo� Town of Southold * P.O. Box 1179 0 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 46340 Date: 07/24/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 1740 Inlet Pond Rd Greenport,NY 11944 Sec/Block/Lot: 33.-3-19.7 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 07/07/2023 Pursuant to which Building Permit No. 49586 and dated: 08/16/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for The certificate is issued to: Michael Tropeano,Linda Tropeano Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49586 07/01/2025 PLUMBERS CERTIFICATION: Aut o ze Signature 1 z - � TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49586 Date: 8/16/2023 Permission is hereby granted to: Tropeano, Michael 1 Boerum PI #5A Brooklyn, NY 11201 1 To: install generator as applied for. ,y At premises located at: 1740 Inlet Pond Rd, Greenport SCTM #473889 Sec/Block/Lot# 33.-3-19.7 Pursuant to application dated 7/7/2023 and approved by the Building Inspector. To expire on 2/1412025. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector pF SOUT��! h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • �� Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Tropeano - Address: 1740 Inlet Pond Rd City: Greenport St: NY Zip: 11944 Building Permit#: 49586 Section: 33 Block: 3 Lot: 19.7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: FM Electric License No: 4099ME SITE DETAILS Office Use Only Indoor 17 Basement C- Service F Solar F Outdoor W 1st Floor r Pool F Spa F Renovation r 2nd Floor I— Hot Tub r Generator Survey 1- Attic r Garage Battery Storage INVENTORY Service 1 ph F Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph [- Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 24kW Generac Generator w/ 200A Transfer Switch Notes: Generator Inspector Signature: Date: July 1, 2025 Sean Devlin ' Electrical Inspector Sean.devlin01town.south old.ny.us 17401 n letPondGenerator OF SOUTyO� l 1 KJ 170 # TOWN OF SOUTHOLD. BUILDING DEPT. coorm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/-REBAR [ ] ROUGH PLBG. [ .] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ].. RENTAL REMARKS:. ��S Le--ra.�nr \Y\ V\.j u DATE INSPECTOR �` r pF SOGIyo h� l0 TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION, [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [. ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR *Of SOUIyOIo —7 LI V I TOWN OF SOUTHOLD BUILDING -DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ _ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING ] FRAMING/STRAPPING [ ] FINAL [. ] -FIREPLACE & CHIMNEY' [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT'CONSTRUCTION { .] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL(FINAL) [ ] CODE VIOLATION- -[ -] PRE C/O [ ]. RENTAL REMARKS: . w44,- I c clxo DATE 7 INSPECTOR ��� 'IELD INSPECTION REPORT DATE COMMENTS can � v1� FOUNDATION(1ST) ------------------------------------ C FOUNDATION (2ND) z W ROUGH FRAMING& PLUMBING J r r� INSULATION PER N.Y. STATE ENERGY CODE 4 C FINAL ADDITIONAL COMMENTS o ° Z N � ` b (,A z T H x _ d b H 4ag�fftlf �� �N_ TOWN OF SOUTHOI.D—BUILDING DEPARTMENT - Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 htt.Ls://www.southoldtownn"y.�ov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only40 i PERMIT NO Building Inspector: La JUL _ 7 20 Appllcatioris and isms must be filled out igI�eir entirety :I,ncamp(,ete x application's wEll not be accepter{ .SNhene;the Applicant�s no`t the:own er,.an BURMINeG DEFT. Owrrer`s Authorizattan`fo"rinx(Page`2)shall=be corn jpteted n 'Erg_• , �1� Date: 011}/NER(S)OF Pit01PER71f Name: 1000-#SCTM T,o _ --- _ 1.. Project Address: �VL_�� O re 0 . Phone#: Email: Mailing Address: CONTACT PER50N s ; Name: Mailing Address: Phone#: . ( (. . Z2 Email. 4e-- Xee-A�lPv�9 Gr f�, Cain ®�St6N PROFfi55IQNALtNFOtYlATION Name: Mailing Address: Phone#: T Email: CO�ITIRIICi RR tAIFORMATIOW Name �c�„o.hy t5ic�n (��ticA ►' Mailing Address: Phone#: 103 f g Email: rn _.. IaESil<1Pti011t Ol`PROPCISf CONSTRl1CTTON r ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated CostofProject. 1 1'dther aca Will the lot be re-graded? ❑Yesmt o Will excess fill be removed from premises? ❑Yes fto 1 _ "` pRORl3'fY`IN�ORIVI�11'ION Existing use of property: � Intended use of property Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes to IF YES,PROVIDE A COPY. check BoxrAfterMeatlPng" The awnerlcontractarjtle�,gn prafessional is responsibie for all drainage and stormiwater issues as pravPded by s Chapter 236 at the?otirn Cade tAPPL1CATfON PS HER£61f MADE toEtha©ulld�ng Department far the issuahcecat a t3uPtdinQ Permit,pursvant to+thr Building Zone,+h Ordinance of tfie Taws ofSauthotd,5uttolk,County,New Yor(t a(id other4ppilcab1 laws,Ordinances of Regt�tatPans,far H►e construtUon of bfuildings,' radiliNons,akeratlons ar for removal ar demalitlon as herePn deze�ibed Tfie apptica►rt agrees to comply wltfi ail appl�wbPe Paws,ordinances;b nld�ng code, housing code;and regulations and to admiEautharizediinsupecEors an premises and in bui�ding(s�fat�necessaryinspectians False statement;smade herein are o _punizhabie as a�Gass A misdemeanor,pursuant,Po;Section;21(P.4S aF,therjUew Y4artt StaUe Penal laws- - k � ` Application Submitted By(print name): /1 e o tt' GgAuthorized Agent ❑Owner Signature of Applicant:Y -� Date: eo` (1:2) STATE OF NEW YORK) SS: COUNTY OF ) �O0 Cr .being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized+to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this y day of �q 20Z�2 LOUISI IT Notary Public Notary Public -State of New Ycik NO.O1 SM6184458 Qualified In Suffolk unit' i My Cor—nission Expires y� 10PE RTY OWNER AUTHORIZATION (Where the applicant is not the owner) ct,I, 1 residing at: 194,0„ �'"h� 1-L _ _ (3ru+lc f g� �doherebyauthorize 3c kck.rl'"U to apply on MY If t he ownrouthold Buil `, ;Department for approval as describ d h-rein. XAN 0 ner's S'" nature Date Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector IrIkt,1 TOWN OF SOUTHOLD ' Town Hall Annex-54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �0'�' Telephone (631) 765-1802- FAX (631) 765-9502 ro`erq r.southoldtownny.gov.�-seand(a)_southoldtownnLgov APPLICATION FOR ELECTRICAL.INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: FM Electric Inc Electrician's Name: Louis_Otega License No.: 4099-ME Elec 'email:finelec01@optonline.net Elec. Phone No:-631 727 6822 _F,1.I request an email copy of.Certificate of Compliance Elec..Address.: 83 Forge Road, Riverhead,NY 11901 JOB SITE INFORMATION (All Information Required) Name: Tropeano Address: 1740 Inlet Pond_Road, Greenport Cross Street: Phone No.: 516 9086498 Bldg.Permit#: L�.GJ�� email.finelec01 @optonline:net Tax Map District: 1000 Section: Block: e Lot: (' BRIEF DESCRIPTION OF WORK INCLUDE SQUARE FOOTAGE (Please Print Clearly): 22KW Generator _ ,. .. � Square Footage Circle. All That Apply:Y: Is job ready for inspection?: ❑ YES❑NO - ❑Rough In ❑ Final Do you need a Temp Certificate?: 0 YES 0 NO Issued On Temp Information: (All information required) - Service Size❑1 Ph❑3 Ph Size: _ .. A #Meters:_ ___ Old Meter# _ __..- ❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead Underground Laterals 1 2 H Frame Pole Work done on.Service? 17 Y r 1N Additional Information: PAYMENT DUE WITH APPLICATION 40, Ful BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex --54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(Dsoutholdtownny.gov— seand a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4 J2 S z3 Company Name: FM Electric Inc Electrician's Name: Louis Otega License No.: 4099-ME Elec. email:finelec01@optonline.net Elec. Phone No:-631 727 6822 I1 I request an email copy of Certificate of Compliance Elec. Address.: 83 Forge Road, Riverhead, NY 11901 JOB SITE INFORMATION (All Information Required) Name: .Tropeano Address: 1740 Inlet Pond Road, Greenport Cross Street: Phone No.: 516 903 6498 BIdg.Permit#: Gj email:frnelec01 @optonline.net Tax Map District: 1000 Section: Block: ®'j Lot: l� BRIEF DESCRIPTION OF WORK, INCLUDESQUARE FOOTAGE (Please Print Clearly): 22KW Generator rV Square Footage: Circle All That Apply: Is job ready for inspection?: [:] ' YE S❑NO ❑Roughr In ❑ Final Do you need a Temp Certificate?: ❑ YES FVI NO Issued On Temp Information: (All information required) - Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 FJ2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION APP 0 ED AS NOTED CIA B.P.# FEE� S BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S 1J HOLD TOW S ._ .TOWN PLANNIN BOARD SDI-Tk+8t6 3�GViGTRC�ST�ES OCCUPANCY OR USE 1S UNLAWFUL VVITHOUT;CEIRTIF1CA- OFOCCUPANCY ELECTRICAL INSPECTION REQUIRED G-EN. ERAC® 20 22 GUARDIAN® SERIES - / Residential Standby Generators Air-Cooled Gas Engine r , INCLUDES: Standby Power Rating G007038-1,G007039-1,G00703&3,G007039-3(aluminum-Bisque)-20 kW 60 Hz • True Power'" Electrical Technology Go07042-2.G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 W160 Hz • Two-line multilingual digital LCD Evolution"controller (English/Spanish/French/Portuguese) • 200 amp service rated smart switch transfer switch available ' • Electronic governorr4f�® . • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.` -.- "Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. cONus or C �L US �htlps://assetsswri.org/library/Directory0/ListedProducls/ Mob�eConstructionlodustry/973DoC20413204-01-01 Rev9.pdf LISTED Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES 0 INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- v' SOLID-STATE. FREOUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. TRUE POWER" ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. TEST CRITERIA: GENERAC TRANSFER SWITCHES:Long life antl reliability are synonymous with PROTOTYPE TESTED NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. r? MOBILE LINO CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. w GENERAC PROMISE O �� GENERAC® 20/22 kW Features and Benefits Engine i • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls, Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to-*1%prevents damaging voltage spikes. • UL 2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD display Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.` • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAL® 20/22 kW , Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC* 20/22 kW Specifications Generator Model 6007038-1,G007039-1 G007042-2,G007043-2 G007038-3,G007039-3 G007042-3,G007043-3 (20 kW) (22 kW) (20 kW), (22 kW) nuous p CRat ed maximum contower capacity(L_P) Y` _ u _y, �20`,000Watts' 22 000Wa't s 20 000 Watts22 000 Watts ' Rated maximum continuous power capacity(NG) 18,000 Watts*+ 19,500 Walls 18,000 Watts` 19,500 Watts` Rated wftage•_,y n -- 7-_ _-- 240 Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 �91.7�/j81.3� 83.3/75.00 91.7/81.3 r 1�Total Harmonic Distortion,em u _ than Main line circuit breaker 90 amp 100 amp 90 amp 100 amp Number of rotor poles 2 lfl y _ Power factor 1.0 MBj requiru remeiit{not inclrided)_ _ �_� __�_ �M _.—J2 Volts Group.26ii 540.CCA mrhimum—or Group 35AGM 650 CCA immmum- '��_= Unit weight(lb/kg) 448/203 466/211 436/198 445/202 f Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 67 . 67 _ 7 � _ 6577 Sn 5 'doup _ Exercise duration - 5 min V Engine Engine type GENERAC G Force 1000 Series ;Number of t:y(inders Displacement Y 999 cc� Valve arrangement Overhead valve lgmhon_Sysiem_._ ,� :': �.5olfd'statewlmagneto Governor system Electronic 4Compressiori ratio Starter 12 VDC� Operating rpm r 3,600 Fue[consumptiori� ]Natural gas ft3/hr(m3/hr) } 1/2:Load' _ :,' •204(5 78) y. 228(6 46); 164(4.64) 203(5.75) - s Full Load 301(8 52) r 327(9 26)- 287(813) 306(6 66) Liqurd propane it/hr(gaVhr)`.[Uhr] ; > « J/2koad 87(2 (2 53)[9 571 86(2 36)[8.95] 92(2 53)[9 57] Fuli,Laad 130(3 56)[13.48] 142(3 90)[14.77] 138(3 74)[1415] 142(3 90)tI14 77] .y....._...._..._._,..u.._<.._........,_�-y..,,+ a.-._,r.,�..._..,�, ___...._._•.,. Note.Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply fl3/hr x 2500(LP)or h3/hr x 1000 ING).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:,AUTO Y� _ y de _n _ AutomaficsFartonvtl6i (attire.Weekl Bi weekl orMorithl selectableexercrser.`r• MANUAL ~' Start with starter control,unit stays on.If utility fails,transfer to load takes place. N OFE '` 3 "' Stops unit:Royrens removed.CdMrcl and dia�ge�still operate, ;;._, ,_b Ready to Run/Maintenance messages Standard _ Engine nm'ho`u�s indica8on:" - -- - - Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) d1"tit'tVolfa'ge`L'dss/Retumio'.UGlityadjust'able(brown'o_efsettm0)n, Future Set Capable Exerciser/Exercise Set Error warning Standard `B:uNA@rm/Mamterranceioga� „* events eac W Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Neer lock eu]'� ,w.,- ~y_y_,�� __�.�_ ___._ .��___,_r_.1"_ ,�.y__ S_tader carin'ot�e engage uhtil 5'sec a(ier engine_has'sloppetl �__ Smart Battery Charger M Standard T_..�.�....�.._.:s.! , Low Battery/Battery Problem Protection and Battery Condition indication Standard sAufomattcVo7taa Re uiatmn.wtm:OVe)rand UnderVolta a Pmtectibn X'Standard�' Under Frequency/Ovedoad/Stepper Overcurrent Protection Standard Safety Fused%Firse ProhI m Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard ;Overcrank/0ierspeed(@ 72Hz)(rpm`5ense Loss ShutdownStandard:: High Engine Temperature Shutdown Standard internal Fault/IgcorrecI Wi protection : - Standard• ` . Common external fault capability Standard t eld upgradatile frmwarey '�A_:.,'.__. x.: __Fn.�_J__u,",.. 's ___.�b._„_�r ._ _ —Standard__ "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level;and also will decrease approximately 1%for each 10'F(6`C)above 60'F(16'C). GENERAC® 20/22 kW Switch Options Service Rated Smart Switch Features 0007039-1(20 kW) _ • Includes digital power management technology(DPM)standard. Model 0007043-2(22 kW) G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. 0007043-3(22 kW) • Up to eight additional large(240 VAC)loads can be managed when used in }No�bfRotes-7_ conjunction with Smart Management Modules(SMMs). Current rating(amps) 200 Volta a ratio AC 120f240,'107f `I • Electrically operated,mechanically-held contacts for fast,clean connections. 2 ._..g_._9 N )r <=,..:y �._:_::71 • Rated for all classes of load,100%equipment rated,both indur..tive and rAsistive Utility voltage monitor(fixed)' -Pick-up 80% • 2-pole,250 VAC contactors. Dropout 65% • Service equipment rated,dual coil designHetum to lJtitity _::� — kpprox l3 ecf _w ' Exercises bi-weekly for 5 minutes` Standard _ • Rated for bath aluminum and copper conductors. _r----._� ...,...— PP EiL or Uj' L lined ;� _ Standard, • Main contacts are silver plated or silver alloy to resist welding and sticking. Enclosure type NEMA/UL 3R • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting tCucdr'^fbreake�I roteffed � �� 22 Op0 flexibility. Lug range 250 MCM-#6� "Function of Evolution controller Exercise can be set to weekly or monthly Dimensions wr 200 Amps 120/240,1e Open Transition Service Rated pz; r, Height Width : H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 4 H2 HI cm 67.95 76.45 26.67 34.29 17.55 3 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM-#4 350 MCM-#6 2/0-#14 L DEPTH —w2—I GENERAC® tic 20/22 kW Available Accessories F } .--*3 rw--^^^--'%-«-:^---r--r--"'' ''a:: `" i. 'S` x --a=-w.s^--* —r w*-cn--nrv+-r}�.ww•^-.r.^ .. r,—*'.-�"� - _ G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery/ for use with all air-cooled standby product(excluding PowerPact®). 13007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0°F(-18°C). (Not necessary for use with AGM-style batteries). [ j G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). ------- G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch 'The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed.Not compatible with 50 amp pre-wired switches. .G007027-0-Bisque 'Fascia Base Wrap Kit ,The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,con- (Standard on 22 kW) toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the Ibase. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corro- Sion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit 'Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The WI-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring Monitor the LP tank's fuel level is an importantstep in verifying the generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large G007006-0(100 electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can amp) reduce the overall size and cost of the system.' G007169-0 Mobile Link°Cellular The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world, Accessories using a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Dimensions & PCs Model UPC 637.fi mm 1218 mm [25.1 int [48.0 in] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm G007042-3 696471074208 28.6ln] G007043-2 696471074215 G007043-3 696471074215 o at o 0 648 mm 1232 mm [25.5 in[ [48.5 im LEFT SIDE VIEW FRONT VIEW y" Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GE N E RACO Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000221268 Rev.B 05/28/2020 SCDHS Rj 20-08 1 3 SURVEY OF PROPERTY N 18 2023 A T GREENPORT TOWN OF SO UTHOLD SUFFOLK COUNTY, N. Y. 1000-33-03-19.7 SL IFFOLK COI NTY DEPARTMENT OF HEALTH SERVICES SCALE: 1'=30 Aft"P'OVAL OF CONSTRUCTED WORKS FOR MAY 5, 2020 A SINCI.E FAMILY RESIDENCE OCTOBER 22, 2020 (PROPOSED HOUSE) FEBRUARY 4, 2021 (URWIES) Date: JUN 7_a_7,173_ H.S. Raf. No. . D �Q_g!3 \ NOVEMBER 22, 2021 (FOUNDATION LOCA770N) sewage disposal and ualcr supply facilities at this loca,�cn h:.,� 1000-33-03-19.3 a been ` SCTM# \ APR/L4, 2023 (FINAL) The sewa G " - inspected and/or certified by this Department or other agencies and t LOT 3 found to be satisfactory FOR K MAXIMUM OF�_8FOROOMS. \ DWELLING ., PUBLIC WATER \\ SOUTHOLD TOWN LOT COVERAGE z:4_• '�� BUILDABLE LAND AREA-26,720 sq.ft. CRAIG KNEPPER, P.E., CHIEF I \ HOUSE = 2,752 sq.ft. OFFICE OF WASTE MANAGEMENT t POOL = 620 sq.ft. \ PA770 (RAISED) = 615 sq.ft. i ,.�,..__�....... ._... SCTM# \ = 3,M 1000-33-03-19.2 3978126720 = 14.911; SCTM# EO t \ 1000-33-03-19.1 1 VACANT ` \ LOT 1—) VACANT 66 \ . 12' 97' EL 41.0' METAL \ 139 ` `N� O S��E� M RK 0� O F UGRND.CELECT IC ACCESS SCTM �j� e��O wP7tOVER (ELECTRIC) RB PRO"��69 EL 41.2' \ 1000-33 03-19.5 EL 37.8' �,L1CJ,�JS, \ \ LOT 5 F � VACANT �� SCTM# 1N cj6• CM F 0. 1000-33-03-19.6 \ O / ?,CN p1A ER �DG1NG \ t3`� C)T 6 23' SEP17C SYSTEM LOCATION DWELLING 12$' sue, O PUBLIC WATER \ AS BUILT Q A /p LP 1 STO BURIED ELECTRIC LINE \ ST 29 , !5 ' WATER Ex 8' LP 2 APR N LP 34 29 METER/VAULT \ "t .7 v� {y`` t MIN. pOR K r— 15.8' / E EC P.IC METER ON Lr G Y:J l ;yq K \ �. ST \ R SFR�FR \ W�\ ~ rn I&s \\ SEP77C SYS7EM 40 0' E ESS Clk 3, (4 BEDROOMS) �' a w AR AWAY "" CK OUSE ]—]200 GAL. 8'0 X 5' DEEP ST � 0) s.a—� �V2NZFS1pRY F EME 42�� ",isysaDW 0.3FE.CER lo 2-80 X 12 DEEP LEACHING POOLs Q0CD F\r SCTM# n O CAN! BE �'FE G� I WL 1000-33-03-19.23 a z EQUIP. N SSONE PASDOL xO �6a ��py i OWNERS : TEST HOLE DATA LOT 23 4 AREAWAY M/CHAEL 7ROPEANO McDONALD GEOSC/ENCE �� i AREAWAY tie, STEP �y i90 LINDA TROPIANO 4-9-2020 DWELLING \�°° 00• 1740 INLET POND ROAD EL. 38.0' PUBLIC WATER �0 ONCE �� ��Ac P C0� �' t SCTM DARK BROWN LOAM OL `� <"y 1000-33-03-19.10 # GREENPORT, NY 11944 39•�'1 � PN710 LOT 7 � " BROWN SILT ML S�oNE �� LOT 10 CA ^jrO�C,MF 0.2 N R KEY O, ; a U /F.�' V4 0.3'E SCTM# t Q = REBAR BROWN CLAYEY SAND _ _� 1 F sp�q' 1000-33-03-19.9 ® = WELL W/TH GRA VEL SC o a, aWc NCE _ �- EL 36 4jd��1 LOT 9 t ® = STAKE O WAR_ R NIN�NG INW FE.COR 5 �� 16' �_ UNJ-EOCK FEN 0.2'S X VACANT = TEST HOLE �N p1CKE� 1 — 1 g0•p0 1 t f^ = PIPE BROWN FINE TO COARSE FE.END f SAND SP — ''--. + REBAR 0.1'Swil- ` = MONUMENT �' 164 HEDGE t 23' EL 33.8' EL 34.,,' S79'54,43' 00 = WETLAND FLAG NOTE.• NO WATER ENCOUNTERED = U77LITY POLE SCTM ALL PROPERTIES W/7NIN 150' ON PUBLIC' # = HYDRANT WATER 1000-33-03-19.22 = LIGHT POLE ELEVA77ONS REFERENCED TO NAVD 88 LOT 22 SCTM# 1 VACANT 1000-33-03-19.8 t ��`svil Va. LOT 8 ����•`t'/y��9 LOT NUMBERS REFER TO "FINAL PLAT ROCKCOVE ESTATES" FILED /N THE SUFFOLK COUNTY CLERK'S OFFICE ON JUNE 11, 2001 AS FILE NO. 106JZ DWELLING PUBLIC WATER ` f r THE LOCATIONS OF WELLS AND CESSPOOLS SHOWN HEREON ARE FROM FIELD OBSERVA77ONS AND OR FROM DATA OBTAINED FROM OTHERS. THEREFORE THEIR LOCATIONS AND OR EXISTENCE IS NOT GUARANTEED. �t� _' ► 6� s� I am familiar with the STANDARDS FOR APPROVAL AND CONSTRUCTION OF SUBSURFACE Sf_WAGE DISPOSAL .� � N.Y.S. LIC. NO. 49618 SYSTEMS FOR SINGLE FAMILY RESIDENCES and will abide by the conditions set forth thereih and on the permit Y.S. LIC, NO. 051132-01 to construct. The location of wells and cesspools shown hereon are from field observations and or from data obtained from others. PECON/C SU YORS, P.C. (631) 765-5020 FAX (631) 765-1797 ANY ALTERATION OR ADD17ION TO THIS SURVEY /S A WOLA77ON OF SECTION 7209 OF THE NEW YORK STATE AREA= 26,720 SO. FT. peconicsurvey0optimum.net EDUCATION LAW. EXCEPT AS PER SEC77ON 7209—SUBDIVISION 2. ALL CER77FICA7IONS HERFON ARE VALID FOR THIS P.O. BOX 909 SMAP AND COPIES THEREOF IGNATURE APPEARS HEREON.ONLY IF SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR WHOSE 12JO O AV EL Y. 1 971 T 20-019