Loading...
HomeMy WebLinkAbout50413-Z %Of$OUTyo`o Town of Southold * * P.O. Box 1179 ion 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46379 Date: 08/07/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 345 Old Cove Blvd Southold, NY 11971 S ec/B lock/Lot: 52.-2-13.2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/06/2024 Pursuant to which Building Permit No. 50413 and dated: 03/11/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: 345 Old Cove Blvd LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50413 7/3/2025 PLUMBERS CERTIFICATION: Aut Cofizeaignature o�SOFFoicoG TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50413 Date: 3/11/2024 Permission is hereby granted to: 345 Old Cove Blvd LLC c/o Nickart Realty Corp 775 Brooklyn Ave Ste 100 Baldwin, NY 11510 To: Install roof-mounted solar panels to an existing single-family dwelling as applied for with flood permit. Solar panel equipment is proposed in the AO-2 flood zone, equipment must be located 2' above the average natural elevation of the property grade. At premises located at: 345 Old Cove Blvd, Southold SCTM #473889 Sec/Block/Lot# 52.-2-13.2 Pursuant to application dated 2/6/2024 and approved by the Building Inspector. To expire on 9110/2025. Fees: SOLAR PANELS $100.00 CO-ALTERATION TO DWELLING $100.00 ELECTRIC $125.00 Flood Permit $150.00 Total: $475.00 Building Inspector SO(/j�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road tw P.O.Box 1179 Co- • Southold,NY 11971-0959 'Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: 345 Old Cove Blvd LLC Address: 345 Old Cove Blvd City: Southold St: NY Zip: 11971 Building Permit#: 50413 Section: 52 Block: 2 Lot: 13.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunation License No: 33412ME SITE DETAILS Office Use Only Indoor W Basement C Service ❑ Solar r Outdoor 1 st Floor ❑ Pool Q Spa I Renovation 2nd Floor IJ Hot Tub ❑ Generator Survey Attic ❑ Garage Battery Storage INVENTORY Service 1 ph ❑ Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph 177 Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 19.32kW Roof Mounted PV Solar Energy System w/ (46)REC420AAPureR Modules, Enphase Gateway w/ (4)20A Circuits to Roof,,-100A Panel, Lineside Tapped in Main Panel Notes: Solar Inspector Signature: X Date: July 3, 2025 Sean Devlin Electrical Inspector sean.deviina-town.southold.ny.us 3450ldCoveSolar SO I Lis 01� � Lis � # TblkWOF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION. [ ] FOUNDATION 1 ST/ REBAR [ } ROUGH PLBG. [ ] FOUNDATION 2ND. [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL ] FIREPLACE & CHIMNEY [ . ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: :�&�- �' n� Loo �e Zom - C� ION-AA - . 7/1 DATE ft INSPECTOR �OF SOUK°# ``] Q .TOWN OF SOUTHOLD.BUILDING DEPT. cau�+� 631-765-1802 INSPECTION . [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINAL c546U [ ] FIREPLACE & CHIMNEY [ ]. FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ . ]. RENTAL REMARKS: Ole- 40, DATE -a INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) — ------------------------------------ C FOUNDATION (2ND) z 0 �cn H ROUGH FRAMING& i PLUMBING S- 1 C r INSULATION PER N.Y. H STATE ENERGY CODE FINAL ADD IONAL COMMENTS Us .r, 3 2� �fo0p� reG / lost xl �45D o Z _1 x x b =�o�gUFFOi��OGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 lei Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov f Date Received APPLICATION FOR BUILDING PERMIT -- For Office Use Only 4 1 r a LZ ,L 1_�._ PERMIT NO.T0 1 Building Inspector: F E S 6 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF:PROPERTY: Name:345 Old Cove Blvd. LLC/Nicholas Paleos SCTM#1000-52-2-13.2 Project Address:345 Old Cove Blvd., Southold, NY 11971 Phone#:516-429-1065 Email:n •aleos hotmail.com Mailing Address:345 Old Cove_Blvd, Southold,_NY 11971� CONTACT PERSON: Name_ Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY-1 1779 Phone#: 631-750-9454 ext 346 Email: ermittin sunation`com_� ____ DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn, Graham and Associates Inc._ Mailing Address:256A Orinoco Drive_Brightwaters,_NY 11718 Phone#:631-665-9120 Email: lenn rahamassociatesny_com _ -- -_. -- ------•-_- _.-- _.9..__.___@9_p@g�g�amassociatesny.com _ _ CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar_Systems_ Mailing Address:171 Remington Blvd., Ronkon-koma,_NY 11779 Phone#: 631.-750-9454 _ Email:-P ermittin @sunation.com _ - - - - ..__ 9 @. DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 53.167.0-0 Will the lot be re-graded? Dyes ®No Will excess fill be removed from premises? Dyes 9No 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes BNo IF YES,PROVIDE A COPY. ❑Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on,premises and in building(s)for necessary inspections.False'statements made herein are- punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State.Penal Law. Application Submitted By(print name): Sco Maskin BAuthorized Agent ❑Owner Signature of Applicant: Date: 3 LYNN VITA STATE OF NEW YORK) Notary Public, State of New York SS: Registration #01V15068399 Qualified in Suffolk County COUNTY OF Suffolk ) My Commission Expires Oct.28, Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and.file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 31 J l day of 3G V)UJ' ' ,20D'j- "i);oil Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Nicholas Paleos residing at 345 Old Cove Blvd. Southold, NY 11971 do hereby authorize Scott Maskin to apply on y ehalf t the T n o Id Building Department for approval as described erein. Owner's Sig re Date C-L 4 �c 10 Print Owner' Name 2 �O�Og�FFO[K�oGy2 TOWN OF SOUTHOLD—BUILDING DEPARTlfIENT ' Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,:NY 11ajtt0�59 2024 Telephone(631) 765-1802 https://www.southoldtownny Floodplain Development Permit Application" PROPERTY INFORMATION: FFlood Zone:EL$ FIRM Panel: SCTM#1000-52-2-13,2 Address:345 Old Cove Blvd. City:Southold Zip:11971 CONTACT.PERSON:- Name:Scott Maskin, Sunation Solar Systems Phone#:631-750-9454 ext 346 Mailing Address:171 Remington-Blvd, Ronkonkoma, NY 11779 PROJECT DESCRIPTION: Installation of solar panels, flat on roof SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT:APPLY)- Type of Structure Type of Structural Activity R Residential(1 to 4 families) ❑New structure ❑Residential(more than 4 families) ❑Demolition of existing structure ❑ Combined use ❑Replacement of existing structure ❑Non-residential ❑Relocation of existing structure ❑ Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) ®Alteration to existing structure ❑Manufactured Home R Other: solar ❑Located on individual lot ❑Located in manufactured home park SECTION Bc OTHER DEVELOPMENT(CHECK ALLTHATAPPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) • Excavation (not related to a.structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I.understand that no work may start until a;permit is issued.The permit may be revoked if any false statements are made herein.If revoked,.all work must cease until permit is re-issued.Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work,is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority orrepresentative to make reasonable inspections to-verifycompliance. Application Submitted By(print nam ): cott Maskin Signature of Applicant: Date: ,`aguFlpj �o + BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o ` ' Town Hall Annex.- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 I rogerr southoldtownnypov—seand@southoldtownny.aov. =� s APPLCCATCON FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: - Company Name: SUNation Solar Systems, Inc. :s Name: Scott Maskin E License No:: 33412-ME email: permitting@sunation.com Address: 171 Remington Blvd. Ronkonkoma -NY 1177.9_ . Phone No.: 631-750-9454 { JOB SITE INFORMATION (All Information Required) ! Name:_ 345 Old Cove Blvd.LLC/Nicholas Paleos F Address: 345. Old C_ove.-Blvd. .Southold, NY 11971 Cross Street: Phone No.: _516-42.971065. - f BIdg.Permit#: 50 Lf email: . n aleos hotmail.com Tax Map District: 1000. _Section 52 _ Block:_2 _ _ Lot: 1.3.2 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of.-solar panels= flat on. roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On AII information required) c Temp Information: ( Service Size 1 Ph 3 Ph Size: _A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect Service Reconnected - Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT-DUE WITH APPLICATION Request for Inspection Formals 2 Z 0 (Er UTILITY Enphase A/C Branch Circuit(typ.) SERVICE — p (typ•) Existing J SUNATION —En hase Microinverter PSEG Utility Meter �. ry Account#-9670122201 COMBINER Meter#-98173829 #' ` # 120i240v Module J-Box(typ.) # # PANEL SUNation Solar Systems SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma,New York 11779 r (631)-750-9454 r , ' IN PV Module(typ.) S 1 t INSTALLER 2004 MAIN NUMBER 4355 EGC Attached To Rail(typ.) - JOB NUMBER ENPHASE GATEWAY C' tNo loads,monitoring oNy) .5�' 23848 2P20A 2P15A Circuit#1 EWE GG Y \ ENPHASE BRANCH CIRCUIT#1— 2P20A 81 J CONDUIT AND CONDUCTOR SCHEDULE - Circuit#2 MAIN CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 2P20A TAG CONDUCTOR Circuit#3 ENPHASE BRANCH CIRCUIT#3 TYPE GAUGE QUANTITY TYPE SIZE LENGTH 2P20A 2P80A 2P20A - ENPHASE BRANCH CIRCUIT#4 Yr• Circuit#4 IQ Combine Sense r Y� j SENS 1 Enphase Q-Cable 12 8 N/A N/A 15 EGc ! ? G (a (No loatls,maNton goNy G e NM 10 8 N/A N/A 30' i MAIN '- 2 Type (1 2? \3' ENPHASE SERVICE � d 3 HWN-2 10 8 PVC SCH.80 1.25" 15 IQ COMBINER DISCONNEC PANEL r N ROOF ATTIC EXTERIOR GC 10 1 PVC SCH.80 1.25" 15' 1 SERVICE RATED 4 HWN-2 4 3 PVC SCH.80 1.25" 10, `4 ENCLOSURE 6 Z m MIN.60A � GC 8 1 PVC SCH.80 1.25" 10' MIN.22kAIC —L O Z U 'D TO EXTERIOR r 5 l}W�2 4- 3 PVC SCH.80 1.25" 10' DISCONNECTING MEANS BUILDING 0 73 i 6 EC l6 1 GROUNDING Q .- 0 N/A N/A 10 ELECTRODE CD (n F 0 M - C: Z to > Qt Maximum AC Operating Current 1� w a�i (D Circuit# PV Module Qty. Micro-Inverter y• W ~ ; E N 1 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A 0 co Enphase IQ7X-96-2-US 12 2 REC420AAPureR 12 P 15.72 A O cz 3 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A LO 4 REC420AAPureR 12 Enphase I07X-96-2-US 12 15.72 A Maximum AC Operating Current(Total) 60.26 A 1 El •�_ .. ONE-LINE DIAGRAM �gTER�p Q� AErn C��S'Ci 5 "� 6 JT� Enphase A/C Branch Circuit(typ.) { Tf UTILITY �{ a SERVICE cc Enphase Microinverter(lyp:) --- --- O V C c �� PSa UtIity Mete.,, p /� QPSUNATION COMBINER �0 A Meteraaimi-I I\V/I ENVY Module J-Bm(tyP.) PANEL 9817 v SUNation Solar Systems SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 NYSERDA LE 4355 EGO Attached To Rail(typJ MOON INSTALLER MAIN NUMBER ENPHASE GATEWAY JOB NUMBER wewa.,roN��c�n 5 2P20A 2P15A 23848 Qrcuh at CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 gP20A 80A ENPHASE BRANCH CIRCUIT A2 O'mmt a2 MAIN TAG CONDUCTOR CONDUIT RUN ^ - TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#3 I�I c rG20ia ENPHASE BRANCH CIRCUIT#4 2P20A 2180A cirP2tr4 comemer 2P20A sensB 1 Enphase O-Cable 12 8 NIA N/A 15' G G ENSE MONRO G � ,erig 2 Type NM 10 8 NIA N/A 30' EGC MAIN 3 HWN-2 10 8 PVC SCH.80 1.25" 15' 1 2 3 ENPHASE IG A/C SERVICE p^j ROOF ATTIC EXTERIOR 10 COMBINER DISCONNECT PANEL CJ GC 10 1 PVC SCH.80 1.25" 15' o 4 HWN-2 4 3 PVC SCH.80 1.25" 10, SERVICER z N 4 ENCLOSUREE 6 z O GC 8 1 PVC SCH.80 1.25" 10' MIN.22A M MIN.22k AIC Z y .p 5 EU 4 3 PVC SCH.80 1.25" 10' DISLON ECrfl1OPMFANS C L 6 EC 6 1 N/A N/A 10' BUILDING a N r GROUNDING ;6 ELECTRODE 0 U) .N LLCC C ca Z U) .Circuit# PV Module Oty- Micro-Inverter Qty. Maximum AC Operating Current rw- N m 1 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A w a U 51 2 REC420AAPureR 12 EnphaselQ7X-96-2-US 12 15.72 A a 3 3 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A LID 4 REC420AAPureR 12 Enphase I07X-96-2-US 12 15.72 A c�cr Maximum AC Operating Current(Total) 60.26 A E 1 -1 ONE-LINE DIAGRAM "Road APPROVED AS NOTED COMPLY WITH ALL CODES OF DATE-! B.P# d NEW YORK STATE&TOWN CODES E 3 C FE J D' �6 BY AS EQU RED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT mma 631-765-1802 8AM TO 4PM FOR THE ( T=RMW= FOLLOWING INSPECTIONS: wmT=%I FOUNDATION-TWO REQUIRED Ity.&Dm FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING $CHO INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS *cJ i5con vx c4 mut+ I� oca I +zal ouf-5 Ide, I abr-l-ed a►nd l FLOOD zoo A _ z COMPLY WITH CHAPTER '`46a FLOOD DAMAGE PREVEN'hON SOUTHOLD- TOWN CODE,. Additional Certification May Be Required. --o amrctO JJA i-jj,jW yj%ijO3 s3cioo uvivar z 3n"xre;iRby W--m Ro U101TIGINOO CIVIA(I-BAW31A P-A :YID TA TK t-,I, n V-,;;T ,na&AyMo�jq 1,911,101 DHT I N-1-, nanual Ito,(Wal MAIM, I-v OVILD It 2UM MOITO UriT,-.- 0.0 fl,09 r R iS03-:1 3MI,TDI-"? jjrk IT COO e _ . a a A Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Building Consultants & Expeditors (631)665-9619 January 30, 2024 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Paleos Residence 345 Old Cove Road Southold, NY 11971 Proposed 19.32 KW PV Rooftop Solar System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. Sic� � D(J 0 C y/ P1 4t Q b a—,el ��f� �� 0 • `mr r x, ED ® m +• t jo NA wkU .w �i 1�x i ., n f9r.i" ♦ r d I ' 5C ��', p � '.�. r'ss _d'! yin '�• COMPACT PANEL 51ZE - 9 A MODULE CURRENT \ COMPATIBLE WITH MLPE If f,. Roau�r EXPERIENCE 410 wP "���� 25 YEAR 19.7 rT2 WARRANTY EFFICIENCY LEAD-FREE 21.2 ELIGIBLE ROH5 COMPLIANT PERFORMANCE � ye., 4,�. ,`♦ „sr�.,fil`��° •�- t+ �,y. y�„�'Y:A�.�,��.��!aiy'W.is?r.+i': REE ALPHA PURER 5ERIE5 RECd PROOUCT .TIONS SOLAR'S MOST TRUSTED G eeol34,61ENERALDATA _ .� �. _ noz2.s l n sl 425 ne.7111 Celltype: 80half-cut REC bifacial,heterojunction cells with ' lead-free,gapless technology IN Glass.. 0.13 in(3.2 mm)solarglasswith anti-reflective surface treatment in accordance with EN 12150 °D1� Backsheet: Highly resistant polymer(black) 17M lbn 1700[671 a Frame: Anodized aluminum(black) & o + j Junction box: 4-part,4 bypass diodes,lead-free _ F IP68rated,In accordance with IEC 62790 Connectors: Staubli MC4 PV-KBT4/KST4(4 mm2) 11.01 011 in accordance with IEC 62852,IP68 only when connected Cable: 12 AWG(4 mm2)PVwire,67+67 in(1.7+1.7 m) 08S0A;; l°lem ip:um in accordance with EN 50618 ± E ll j Dimensions: 68.1 x 44.0 x 1.2 in(20.77 ft2)/1730 x 1118 x 30 mm(1.93 m2) } 59423123.4iMI21 w 45I781 22.5[0.91 Weight: 47.4lbs(21.5 kg) Origin: Made in Singapore Measurements in inches(mm] ELECTRICAL DATA Product Code:RECx_xxAA PURE-R CERTIFICATIONS: Power Output-PMAx(Wp) 400 410� 420 �- 430 IEC61215:2016,IEC61730:2016,UL61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC 61701 Salt Mist Nominal Power Voltage-VMpp(V) 48.8 49.4 50.0 50.5 IEC62716 Ammonia Resistance Nominal Power Current-IMpp(A) 8.20 8.30 8.40 8.52 UL61730 Fire Type Class 2 Open Circuit Voltage-Voc(V) 58.9 59.2 59.4 59.7 IEC62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) Short Circuit Current-Isc(A) 8.73 8.81 8.89 8.97 IEC62321 Lead-freeacc.t a ROHS EU 863/2015 Power Density(W/ft2) 19.26 19.74 20.22 20.7 ISO 140 0 1.ISO 9 001,IEC 45001,IEC 62941 Pane I Efficie ncy(%) 20.7 21.2 21.8 22.3 v of Power.Output-PMAx(Wp) 305 312 320 327 °O- ❑ Wd-Fe F NamInaIPowerVoltage-VMpp(V) 46.0 46.6 47.1 47.6 TEMPERATURE RATINGS' _ NominalPowerCurrent iMpp(A) 6.64 6.70, 6:78 6.88 Nominal Module OperatingTemperature: 44°C(±2°C) Z Open Voltage (V) 55.5 55.8 56.0 56.3 ° P g oc Temperature coefficient -0.26/°/°C Short Circuit Current-Isc(A) 7.05 7.12 7.18 7.24 Temperature coefficient ofVoc: -0.24%/°C Valuesat standard test conditions(STC:air mass AM IS,irradiance10.75W/sgft(1000W/m2),temperature 77"F(25°C),basedona production spread Temperature coefficient oflsc: 0.04%/°C with a tolerance of PM.,Va&Isc t3%within one watt class Nominal module operating temperature(NMOT:airmass AM 1.5,irradiance 800 W/m', temperature 68°F(20'C),windspeed 3.3 ft/spm/s).'Wherero indicates the nominal power class(P,.)at STC above. 'The temperature coefficients stated are linearvalues MAXIMUM RATINGS WARRANTY DELIVERYdNFORMATION - �. Operational temperature: -40...+85°C Standard RECProTrust Panels per pallet: 33 Systemvoltage: 1000V InstalledbyanREC No Yes Yes Panels per 40ftGP/high cube container: 858(26pallets) y Certified Solar Professional t Test load(front): +7000 Pa(146 lbs/ft2)' System Size All 425 kW 25 500 kW Panels per 53 ft truck: BS8(26 pallets) •3 a Test load(rear): 4000 Pa(83.51bs/ft2)' product Warranty(yrs) 20 25 25 Series fuse rating: 25A Power Warranty(yrs) 25 25 25 LOW LIGHT_BEHAVIOUR' _ o Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module at STC: 231 'See installation manual formountin instructions. Power inYearl 98% 98% 98% o .m Design load-Test load/l.S�safetyfactor) ° c Annual Degradation 0.25% 0.25/° 0.25% ° ..--....... o Power in Year 25 92% 92% 92% 1---------i---------' See warranty documents for details.Conditions apply " - z n Irradiance(W/m2) Availablefrom: N 0 m 1 i � O N Founded in 1996,REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable solar power.As a Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar panels it manufactures. • ' Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs inNorthAmerica,Europe,andAsia-Pacific. www.recgroup.com Data Sheet Enphase Microinverters Region:AMERICAS 1 Q7X Microinverter The high-powered,smart grid-ready IQ7X Microinverter dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase Energy System,the IQ7X Microinverter integrates with the IQ Gateway, IQ Battery,and the Enphase Installer App monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25-years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling Y Built-in rapid shutdown compliant(NEC 2014,2017&2020) Efficient and Reliable • Optimized for high powered 96-cell*modules • Highest CEC efficiency of 97.5% • More than a million hours of testing • Class II double-insulated enclosure • UL listed 0 Smart Grid-Ready • Complies with advanced grid support,voltage and frequency ride-through requirements .oM - Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA)and U` IEEE 1547:2018(UL 1741-SB,3''Ed.) *The IQ7X is required to support 96-cell modules. To learn more about Enphase offerings,visit enphase.com EN PHAS E• I Q 7 X-D S-0 0 9 9-E N-U S-12-27-2 0 2 2 IQ7X Microinverter Q INPUT DATA(DC) IQ7X-96-2-US Commonly used modulepainngs" 320W=46gW Module compatibility 96-cell PV modules Maximum input DC voita e 79,5V ; Peak power tracking voltage 53V-64V Operating range 25V 79 5V' Min/Max start voltage 33V/79.5V ;Nlax,DC short circuit current(module.lsc) 10A. Overvoltage class DC port II DGportbackfeed current OA PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240VAC @ 208VAC Peak output power „ . 320VA Maximum continuous output power 315VA Nominal(L L)voltage/range? 240V/211 264V 208V/163 229V w _ Maximum continuous out current 1.31A(240VAC) 1.51A(208VAC) Nominal frequency_ "- Extended frequency range 1 49 68 Hz AC short_circuitfault current over 3'6y6les ' 5 8 Arms Maximum units per 20A(L-L)branch circuit3 12(240VAC) 10(208VAC) ..Overvoltage class AC port:._ _A :,: f III AC port backfeed current 18 mA _ IF f act�,___orse_tt._i__ng zwf Power factor(adjustable) 0.85 leading...0.85 lagging EFFICIENCY @240VAC @208VAC 1,.CECweighted:efficiency i ',975°i 97.0-% MECHANICAL DATA ,'Ambient temP erature range. 40°C to+60°C ._u - _. Relative humidity range 4%to 100%(condensing) Co inn ectortylie(IQ7X 96 2 US) MC4(or Amphenol H4.UTX with optional'Q DCC'5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1 O8 kg _ 38'16s) Cooling Natural convection-No fans ;:Approved for wet locations Yes Pollution degree PD3 fnclo'sure` 1 bass ll double insulated corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication,(PLC) Monitoring Enphase Installer App and monitoring options Compatible with IQ Gateway Disconnecting means, The AC and DC connectors have.been evaluated and approved by UL for use as the load break dlscohnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA),IEEE 1547:2018(UL 1741-SB,V Ed.) HEI Rule 14H SRD 2.0 UL 62109-1,FCC Part 15 Class B,ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017,and NEC 2020,section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.Pairing PV modules with wattage above the limit may result in additional clipping losses.See the compatibility calculator at httos://link.enohase.com/inodule-com atn ibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com Oc 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ7,IQ7+,IQ Battery,Enphase Installer App,IQ Gateway, On C w I P u A S E and other trademarks or service names are the trademarks of Enphase Energy,Inc. G 7 V C l IQ7X-DS-0099-EN-US-12-27-2022 e► SERIES 100 FLASHED L FO SnapNrackReside-Reside-ntial PV MountingSystems } 4-Y, �a"A'c'"•xr ]A j4,� y 3„The SnapNrack line of solar mounting A"'3t�4a i` �._ $r f •�f d"r`-t"���y �r�' A 4 K g�•�i-�-_ systems is designed to reduce total installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify F �{ installation and reduce costs. r- Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative r+, solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps• shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your,SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.sna,pnrack.conn/contact SnapNrack- Patent Pending FW Moo uhN n Gg' SyoUifm - - d i I Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1-spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions r5NAPNRACK CHANNEL NUT t �SNAPNRACK 92 DEGREE L-FOOT,CLEAR -S)1618 FLANGE NUT / �5)1618 X 1IN BOLT WITH SPLITLOCKWASHER ,-SNAPNRACK COMPOSMON FLASHING 3.13 `-SNAPNRACK L-FOOT BASE .88 Patent Pending SnapNrack Flashed Foot TechnicalData Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack' (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. SERIES 100 UL ROOF . • • • • Soluti(n The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) � � rya module installation system. Series 100 UL is Listed ------------_______,-_--.__.__.__ _ to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configuresnapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type,Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail _ channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules p`. LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Standard Rail c SnapNrack Bonding + Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack Bonding SnapNrack SnapNrack Adjustable End Bonding �� gases Clamp Top 4' Mid Clamp a SnapNrack SnapNrack Banding Banding SnapNrack Stainless y. Adjustable End Bonding Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding J SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt r with Flat Washer IF F IF SnapNrack Bonding Universal End Clamp SnapNrack—* Bonding Standoff Clamp Assembly SnapNrack Serrated Stainless__,ASnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack ^, Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff a SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) o SnapNrack Metal Roof Mill Finish L Foot Base Assembly L Foot Base Flashing SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack • • Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solu Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. v UTILITY METERPROPOSED RESIDENTIAL PLAN KEY ®-SERVICE DISCONNECT PV1-0 COVER SHEET ®-SUPPLYSIDECONNECTION Al-1 PARTIAL ROOF PLAN ®'AUTOMATIC TRANSFER SWITCH PHOTOVOLTAIC SYSTEM Al-4 ROOF ACCESS PLAN ®-GAS METER 1 A2-5 FLOOD ELEVATION M-MAIN SERVICE PANEL \\ ®-SUB PANEL 171 RE INSOLARSYSTEMS INSTERDA ALLER 4355 S1-1 STRUCTURE (10)PROPOSED PV MODULES (4)PROPOSED PV MODULES (4)PROPOSED PV MODULES (9)PROPOSED PV MODULES 171 REMINGTON BOULEVARD INSTALLER ®-WIRELESS ROUTER E7-1 ONE-LINE DIAGRAM RONKONKOMA, NEW YORK 11779 NUMBER ®-INVERTER E2-1 PV LABELS ®.ENPHASE b COMBINER G1-1 PV PHOTOS PANEL PHOTOVOLTAIC Paleos Residence Q-ELECTRIC VEHICLE CHARGER / 345 Old Cove Blvd., Southold, NY 11971 ®-ENPHASE ENVOY Z Z /- �-SENSE CONSUMPTION MONITOR O ° ' r rawn By: M. Danziger-01/30/2024 - - ❑ ED Ajic� ®-AC DISCONNECT J y0" -TESLA GATEWAY ACCESS W ROOF LU ®•lESLA POWERWALL E ACCESS Yw O/� ® QO ap ROOF IQ -ENPHASE SYSTEM CONTROLLER •ENPHASE ro LOAD CONTROLLER ®•ENPHASE IQ Io BATTERY / ®-ENPHASE IQ 3 BATTERY ®-GENERATION PANEL 029 ®-BACKED UP LOADS CENTER -18"-VENTILATION -18"-VENTILATION 0-VENT PIPE TF OF NEB --EXTERIOR LOCATION --1ST FLOOR LOCATION Building Review Note .-BASEMENT LOCATION o Z Z Town building examiner has received the enclosed document for minimum acceptable w-GARAGE LOCATION o o plan submittal requirements of the town as specified in the building and/or Residential a g Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York z z 10 State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM LU LU osc interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Oty: (46)REC420AAPureR the work in this document is: (e) EV Accurate Conforms with governing codes applicable at the time of submission Module Dimension: 68.1"x 44"x 1.211 SS MSP (EXT) • Conforms with reasonable standards of practice and with view to the Module Weight/PSF: 47.4 Ibs If 2.27775108121096 PSF = safeguarding of life,health,property and public welfare is the responsibility of the licensee. Micro Inverter: (46)Enphase 107X-96-2-US FRONT OF HOUSE-FACING STREET OR DRIVEWAY Structural Statement System DC Rating: 19.32 kW (5)PROPOSED PV MODULES (6) OPOSED PV MODULES System AC Rating: 4 PROPOSED PV DULES The existing structure is adequate to support the new loads imposed by the Y g: 14.4624 kW/AC ( ) (4)PROPOSED PV MODULES photovoltaic module system including uplift and shear. The existing rafter sizes Aurora Estimated AC Production: 19,586 kWh/yr and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be 39, provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 mO COVER PAGE JOB# 23848 REVISION # N/A ci SUNATION REVISED BY N/A D AO— WAX' �5 ROOF 6 ROOF 7 ROOFAREA CS7 C \ PHOTOVOLTAIC MODULE s-r ��.� 0298 1 ,O CIRCUIT 1 —j y..� CIRCUIT 4 3 \ CIRCUIT 2 CIRCUIT 3 / 'sY• } \ 77 W /• • '� �" 0 ��� • • RIDGE CAPPING \ 0 ( SUNATION TYP.) 3I I— __ RIDGE `",:I: ..I'; RIDGE w 1 C7 A , � : ' ��� o •• • • • • •i� Z) SUNation Solar Systems 0 171 Remington Blvd. / • • X \ C Ronkonkoma,New York 11779 Cj / \ (631)-750-9454 CIRCUIT 2 CIRCUIT 3 ¢. • • \ \ NYSERDA INSTALLER 4355 CIRCUIT 1 � � �� NUMBER \ 2015' 20$ JOB NUMBER 23848 ROOF \ ROOF 5 GUTTER ,'� ,r.�r• ,` ' ,� ,,, GUTTER a, W }} 3,9}t• o ROOF 2 - p 1 ROOF 2 J Z Z `V a: O H a): o a) N o iu tt 0 a) N Z LL ,y _2 CO 1942• w2• ,98• W [U N a ROOF ROOF ~ T fA U -o c O ro ,n p v ch �— Attachment Spacing: Portrait Attachment Spacing: Landscape Roof# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner 39' 1 Southwest Roof 10 2310 340 9.1/12 64" 32" 16" 64" 48" 48" 2 FOH Southeast Roof 11 1410 340 9.1/12 64" 32" 16" 64" 48" 48" 3 Southwest Roof 4 2310 360 9.6/12 48" 32" 16" 64" 48" 48" 4 Northeast Roof 4 510 360 9.6/12 48" 32" 16" 64" 48" 4811 VV 5 Northeast Roof 9 510 340 9.1/12 64" 32" 16" 64" 48" 48" 1/8" = 1'-0" 6 Southwest Roof 4 2310 360 9.6/12 48" 32" 16" 64" 48" 48" 7 Northeast Roof 4 510 360 9.6/12 4811 32" 16" 64" 48" 48" Al 1 PARTIAL ROOF PLAN i SOLAR ENERGY SYSTEMS -�E ED ARc (NY) R324.6 Roof access and pathways. Roof access, pathways and GJ setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be �0 required to provide emergency access to the roof,to provide pathways 2 to specific areas of the roof, provide for smoke ventilation opportunity F'► areas and to provide emergency egress from the roof. 1 Exceptions: A 1. Detached, nonhabitable structures, including but not limited to �F O N�\104 O detached garages, parking shade structures, carports, solar trellises and similar structures, shall not be required to provide (10) PROPOSED PV MODULES (4) PROPOSED PV MODULES (4) PROPOSED PV MODULES (9) PROPOSED PV MODULES roof access. 2. Roof access, pathways and setbacks need to be provided -- where the building official has determined that rooftop operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two \E <7V / `✓ SUNATION units vertical in 12 units horizontal(17-percent slope)or less AA [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate Z Z SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches _O _O 171 Remington Blvd. P: �: Ronkonkoma,New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one Q J J (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. l­_ For each roof plane with a photovoltaic array, a pathway not less than ACCESS `\ Z Z / 36 inches (914 mm)wide shall be provided from the lowest roof edge ROOF > > NYSE 4355 ACCESS INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an ❑ co io ROOF NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. _ 23848 �Qv v Q Pathways on opposing roof slopes shall not be located along the same plane as the truss, rafter, or other such framing system that supports the pathway. I ` Exception: 18"-VENTILATION -18"-VENTILATION 1. Access pathways shall not be required on roof slopes containing < O photovoltaic modules, panels, or an array where the opposing o^, or adjacent roof slope is an access roof. r N Z } Access Roof-A roof surface that: ° Z Z \ a, a o 7�5 O O Q c 0_r o 1. Can be accessed from the ground by the fire service. ~¢ ¢ a) 2. Is capable of providing fire service access to the ridge or peak J J a F of an opposing or adjacent roof surface that contains w w IQ n Z o _ o photovoltaic modules,panels,or an array. > > DSC — a) m 3. Is relatively free of vents,skylights,conduits, mechanical ' equipment and other such obstructions. > 0 °r° °r° (G) EV N a 0 m 4. Does not contain photovoltaic modules, panels or an array,or is a 3 a single ridge roof where the maximum edge to edge width ofVV SS MSP� (EXT) o the photovoltaic panel system does not exceed 33 percent of c�, the ridge length. L J V\Al> N [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be located less than 18 inches(457 mm)from a horizontal ridge. (5) PROPOSED PV MODULES FRONT OF HOUSE - FACING STREET OR DRIVEWAY (6) PROPOSED PV MODULES 39° [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels (4) PROPOSED PV MODULES (4) PROPOSED PV MODULES and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm)wide shall be provided to the emergency escape and rescue opening. N.T.S. Al =4 ROOF ACCESS PLAN �;,�� EL kocy'� Typical Attachment Method �`' ' Ilk RIDGE 611p SNAP'N'RACK ULTRA RAIL PHOTOVOLTAIC 201-611 �L-FOOT AND RAIL ASSEMBLY MODULE -314" MODULE SPACING BETWEEN ROWS AND COLUMNS (TYP.) WOOD SCREW FASTENER J SUNATION i RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER SHINGLE(TYP.)SPHALT NYSERDA 4355 INSTALLER 2'' X 10" / 16" O.C. NUMBER JOB NUMBER 23848 PLYWOOD DECKING (TYP.) —-- SOFFIT WOOD FRAMING EXTERIOR (TYP.) WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" - - 15'-9" IIIIIJ T ROOF SECTION (TYP.) ROOFS '1-8' CO N SCALE: N.T.S. } N z C) Z a) - r SOLAR MODULE FRAME U O NOTE:314'SPACING ' BETWEEN MODULE ROWS Q (D Roof# Rafter Size/Spacing Max Span Material Layers Sheathing T AND COLUMNS. O I) 1 2"x 10"/16"O.C. 15'-7.5" Composite Shingles 1 Plywood HEIGHT ADJUSTABLE 1L L-FOOT(TYP.) Z U) > Q 2 2"x 10"/16" O.C. 15'-9" Composite Shingles 1 Plywood END CLAMP W m m (TYP.) 3 2"x 10"/16"O.C. 14'-511 Composite Shingles 1 Plywood N a_ o SNAP'N'RACK 4 2"x 10"/16"O.C. 14'-6.5" Composite Shingles 1 Plywood e.a' ULTRA RAIL U m (TYP.) � 5 2"x 10"/16" O.C. 14'-911 Composite Shingles 1 Plywood HEIGHT OFF OF O ROOF SURFACE CZ i 6 2"x 10"/16" O.C. #REF! Composite Shingles 1 Plywood I RT MINI Co (TYP•) 7 2"x 10"/16"O.C. 14'-4.5" Composite Shingles 1 Plywood Typical Module PEST WRAP CUT Side Profile AWAY FOR CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX SPEED(MPH.) SPECIAL WIND ZONE CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE S 1 1 LOAD EFFECTS ZONE 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE U) OF N v�,_. Enphase A/C Branch Circuit (typ.) UTILITY SERVICE ti Enphase Microinverter(typ.) ti Existi M �J PSEG Utility Meter S V NNT ION COMBINER Account Meter#698173829 Module J-Box(typ.) PANEL 120/240V SUNation Solar Systems SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 200A INSTALLER R 4355 � EGC Attached To Rail(typ.) MAIN NUMBER I ENPHASE GATEWAY ' JOB NUMBER (No beds,mongoring only) i-C 21`20A 2P15A :J 23848 Circuit Em�..•o.M•r CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 2P20A 80A 1 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 r f Circuit#2 MAIN J 2 ENPHASE BRANCH CIRCUIT#3 Circuit cuit#3 TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#4 2P20A 2P80A 2P20A Circuit#4 IO Combiner Sense 1 Enphase Q-Cable 12 8 N/A N/A 15' � ! SENSE MONITO Sense EGC I No wms.morNdWng om i G G G 2 Type NM 10 8 N/A N/A 30' r\ MAIN T 3 HWN-2 10 8 PVC SCH.80 1.25" 15' �/ 2 3 ENPHASE A/C SERVICEIt ROOF ATTIC EXTERIOR IQ COMBINER y DISCONNECT PANEL r N GC 10 1 PVC SCH.80 1.25" 15 � r o 4 HWN-2 4 3 PVC SCH.80 1.25" 10' SERVICE RATED } N �\4 ENCLOSURE 6, z O GC 8 1 PVC SCH.80 1.25" 10' MIN.60A � 5 HWN-2 4 3 PVC SCH.80 1.25" 10, MIN EXTERIORZ r _ O � o C:) 6 EC 6 1 N/A N/A 1 O' DISCONNECTING MEANS BUILDING Q o GROUNDING O ELECTRODE M U) 0) cf) N C Z O Circuit# PV Module Qt Y Micro-Inverter aty. Maximum AC Operating Current F a) m 1 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A N o >, 2 REC420AAPureR 12 Enphase IQ7X-96-2-US 12 15.72 A U m 3 REC420AAPureR 11 Enphase IQ7X-96-2-US 11 14.41 A to p 4 REC420AAPureR 12 Enphase I107X-96-2-US 12 15.72 A cc Maximum AC Operating Current(Total) 60.26 A E1 = 1 ONE-LINE DIAGRAM aR�e��M MX 4 w I RED,q ASa �C, ASCE Hazards Report may [l.v Address: Standard: ASCEJSEI7-16 Lrtidlda; 41.088794 r , AEC A- y .- 345 Old Cove BW Risk Category:it -72,413265 ld.New York 11971 Soil Class: undefined Elevation: 6-5713872673710005 6 Z „97, tNAvn 661 0 Toprnt NF)IL FlRMvuaw Full FIRM 1 %,+ '�'a, Z tl CAd the p n tod aM dri on the mep to plxo Me /�f 2)ChooseIDuwreapint„te FlRMelti wfull-,im ` 'r N � ` , 817 �1�'E+mrte'Thap.xe:a may take up toe /:- - v" �� f 4 RRMETfE /J ! \J SUNATION r \ SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 ' ? + , ,• NYSERDA 11 f y � ', INSTALLER4355 NUMBER JOB NUMBER 23848 4 �` ti� 1 s �, } N el an �i 70 Z U O i - CE - ` 7P -Ft Y C) LO cz '- _ -- " M 7 k• N.T.S. ^ i AL FLOOD ELEVATION REDq� LABEL LOCATION: LABEL LOCATION: �C, rt ,DELPHOTOVOLTAIC AC DISC60NNEC MAXIMUM AC K C'Sj � rK OG OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Service DisconnectMAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE 2 n •MINAL OPERATING CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. * e., �►. Z —� CURRENT 1 of `NEC 2017 690.54/NEC 2017 690.13(B) NEC 2017 705.10 (J! I', Second • - �� 9 Meteri Located next to - . E V Service Disconnect ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Disconnect THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND " LOAD SIDES MAY BE ENERGIZED This building is eq"Power SUN/�TION IN THE OPEN POSITION • • Interconnected E aHorovoLrac rrloola_Es aRoouce lx voLrAGEProduction WHENEVER THEYARE EXPOED TO SUNLIGHT D• OT REMOVEA SUNation Solar Systems Source Type: 171 Remington Blvd. Solar Photovoltaic Ronkonkoma,New York 11779 (631)-750-9454 Disconnect is Located: Inlenor: Basement: Garage: Exterior: IN S 4355 Front: Rear: LH Side: INSTALLER RH Side: Other Location: NUMBER SUNation Solar Systems SOLAR SYSTEM EQUIPPED 631-750-9454 WITH RAPID SHUTDOWN JOB NUMBER w ww .sunation.corn 23848 TURN RAPID SHUTDOWN SWrrCH TO THE PHOTOVOLTAIC SYSTE "OFF'POSITION TO wrss SHUTDOWN PVSYSTEM EQUIPPED WITH RAPID AND REDUCE THE SHOCK HAZARD SHUTDOWN IN ARRAY Lu CA It r CV ,— O CV Z CD CY) Z Q) - r O o 0 2 o IM Q) U) N LL UJ 0) m N d > U m O Ln p cY) E2= 1 PV LABELS \� E ED q,, kocy'� v 817 F ENN' SUNATION SUNation Solar Systems 171 Remington Blvd. _ Ronkonkoma,New York 11779 y (631)-750-9454 > NY SE RD LLE A- 4;' INSTALLER NUMBER —Wd%lff 5 5 JOB NUMBER 23848 ARRAY LOCATION(S) ARRAY LOCATIONS) SATELLITE IMAGE VIA GROUND VIA ROOF B T J ��T V! N r O CD co .. .•- Z > r & ------------- 0 i 0) cf) N Cc LL 7C) —Y pSlt i E Z — _... _ 4 C z k t'aa'sF>'•z YA ( \\ ICJ VAN W (1) ED e O ` - C) cz m . , . ,_ -` Cy) SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 =1 PV PHOTOS