Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51763-Z
ho��°f SO�lyo�o Town of Southold * * P.O. Box 1179 {0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46264 Date: 06/24/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1725 King St Orient, NY 11957 Sec/Block/Lot: 26.-2-43.4 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/12/2025 Pursuant to which Building Permit No. 51763 and dated: 03/19/2025 -- Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Rama Rao ,Eleanor Thomas Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51763 6/23/2025 PLUMBERS CERTIFICATION: "ILI u ho ' ed ignature fSol,, TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51763 Date: 03/19/2025 Permission is hereby granted to: Rama B Rao 501 E 87th St Apt 1G New York, NY 10128 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 1725 King St, Orient, NY 11957 SCTM#26.-2-43.4 Pursuant to application dated 02/12/2025 and approved by the Building Inspector. To expire on 03/19/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total $325.00 ilding Inspector OF SO�jyQl - o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q �. • �o Jamesh _southoldtownny.gov Southold,NY 1 1971-0959 Q �yCum,��' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Rama Rao Address: 1725 King Street ' city:Orient st: New York zip: 11957 Building Permit#: 51763 Section: 26 Block: 2 Lot: 43.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Greenlogic LLC. Electrician: Robert Skypala License No: ME-43858 SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 4.6KW AC/ 5.5KW DC roof mounted system with 12 panels[REC460AA PURE-RX] 12 microinverters[IQ8X-M-US] with 2 fused ac disconnects, 1 combiner panel Notes: solar energy system Inspector Signature: Date: June 23, 2025 1725 king st 1 i 67 `0) �p 3 Z C EI V E • 2025 Building Town of Southold M } Lt � q t D - ho��0ES0UTyolo �. � ��. TOWN, OF SOUTHOLD BUI NG DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ . ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE'& CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [, ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [A ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O. [ ] RENTAL REMARKS: 60 16Lr f nff A �o 4e, a-wL,e x av of iQ r - �1G DATE I INSPECTOR OF SOGIyO� # # TOWN OF SOUTHOLD BUILDING- DEPT. 631-765-1802 INSPECTION . [ ] FOUNDATION 1 ST/ REBAR [YIR UGH PLBG. ]. FOUNDATION 2ND [ ULATION/CAULKING ] ' FRAMING/STRAPPING [ . AL�o f w [ ] FIREPLACE- & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ .. ] FIRE RESISTANT PENETRATION [ ] 'ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: u upto-1111- DATE 0^Y INSPECTO Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B Ph: 631-988-0000 Bohemia, NY 11716 G c solar@pacificoengineering.com May 19, 2025 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Thomas, Eleanor 1725 King Street Permit Number: 51763 Orient, NY 11957 1 have reviewed the solar energy system installation at the subject address on May 19, 2025.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer Pacifico Engineering P.C. Certificate#0018074 PA 066182 Ralph ®F r� ngineer NY 066182/Exp.Date 1/31/28 FIELD INSPECTION REPORT DATE COMMENTS !FO FOUNDATION INSPECTION 0 N (1ST) --------------------------------------- FOUNDATION (2ND) ROUGH FRAMING& PLUMBING INSULATION PER N. Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 0 Et- c-�sN --------------- cl TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ¢ m Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southol.dtoMmny.$ZOV APPLICATION FOR BUILDING PEPERMITQV�D aie Received F E6 For office Use only Depa�m at PERMIT NO. Building Inspector: 13V'1161n p$sootloo 'SO Applications and ety ,forms must be filled out in the r,ent�rincorriplete applications will not be accepted Where the Applicant is not the owner;an Owner's Authorization form(Page 2)shall Iae completed w y F Date:1/14/2025 q 01NNER�S}OF PROPERLY s s a s Name:Eleanor Thomas scTM#s000 26 2 43 4 Project Address 1725 King Street, Orient, NY 11957 Phone#:646-234-4000 _.. _ Email:ethomasOmeteorallc com ____ � Mailing Address 501 East 87Stry Apt„1 G, New York, NY 10128 CONTACT PERSON r Name:Barbara„ GreenLogicmLLC Mailing Address:97 North Sea Road, Southampton NY 11968 Phone#:631-771-5152 x117 Email:BarbaraOGreenlogic com DESIGN PROFE5SIONAL 1NFORMATItaN a Name mPacifico Engineering PC _.__.....m.. Mailing Address:700 Lakeland Avenye,Suite 2B Bohemia., NY 11.71.6__.. Phone#:�#..631988.OD00..., _�.,... .. _._.... . Email:so,lar rifacificoengineenng com ��. E CONTRACTOR IF4FORMATION ^ . F Name:GreenLogicLLC _Mailing Address:97 North wSea„NRoad, Southampton, NY 11„968 Phone# 631-771 5152 _ DESCRIPI"IO m_... . _ Email AM0Greenlogc.com__.. N OF PROPOSED,CONSTRUCTION $ ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated cost of Project: bother Solar Panels $ 22,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Slrigle family_dwelling Intended use of property:Single family dwelling Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ®No IF-YES, PROVIDE A COPY. Ed Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION Is HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,county,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Class'A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):GreenLogic LLC BAuthorized Agent DOwner Signature of Applicant: —�� Date: t l STATE OF NEW YORK) II// SS: COUNTY OF Suffolk ) Ne$im Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before met this day of = n AA 20a5 Notary Public BARBARA A CASCIOTTA Notary Public-State of New York PROPERTY OWNER AUTHORIZATION No.01CA4894969 (Where the applicant is not the owner) �Itiedin Suffolk County Commission Expires May 11,20V I, JFLCAt40(4 L 74on(IA5 residingat 1-425 k;fJ& S}rf�'1 OQi>:N'i do hereby authorize GreenLoglc LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. / ner's Signature . Date CLL-A4o2 (- . 'lltoMIN5 Print Owner's Name 2 GREENLOGIC® ENERGY February 7, 2025 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Eleanor Thomas 1725 King Street Orient, NY 1000-26-2-43.4 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels/inverters • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance 0 GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$325 ($100 Building Permit/$100 CO/$125 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, E V E Jqada%a ecociotta F E B 1 2 2025 Barbara Casciotta Building 1)e10artrnent Account Manager Town of Southold Barbara@Greenlogic.com GREENWR1C7l?L1Cs vEkfenl!i*c.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 Sff�"t+Y. BUILDING DEPARTMENT- Electrical Inspector b d2� TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 ` Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny Qov - seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/7/2025 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greentogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Eleanor Thomas Address: 1725 King Street Orient NY 11957 Cross Street: Phone No.: 646-234-4000 Bldg.Permit#: ' 5 email: ethomas@meteorallc.com Tax Map District: 1000 Section: 26 Block: 2 Lot: 43.4 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system * (12) REC460AA PURE-RX panels Et (12) Enphase IQ78x micro inverters (1) Enphase IQ Gateway ENV2-IQ-AMI System Size: 5.520KW Check All That Apply: Is job ready for inspection?: DYES 0 NO ❑Rough In OFinal Do you need a Temp Certificate?: OYES [:]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx GREENLOGICO ENERGY 0 g 2025 May 21, 2025 ®e�art�IdTownt n sovtb The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Projectlnfo: Building Permit No. 51763 Eleanor Thomas 1725 King Street Orient, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, Jaw C'cr dotta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 r — F o m 40005trmddr Avarwo,Wyorh-4 Nen'r rk IM01 TEST HOLE L 1-601-'T--M03 fox.651.=,0144 . ww.nu+.tnaasemaa actrnbreyo�.genglroerVgAem wtearrstrzo2. a�'� aA' 1V Mzttc�c�5otta#e� o / aa9KemA*+ H-11 K Yowrj,='Surveyor ®o mT Donlol A 14--,LmG Surveyor i SITE DATA AREA=40,005 SQ.FT. S ) `VERTICAL DATUM a NAVD(1988) tm 1-2 N "art z0 Re�KDblz O'9ZacKed &Aadrel E.Lu LAtMR` wwstwvst P% 1].9g 1a.39 4-�e� l.50 17.2 . %s6�v� N75 fl \ �''y9 n.sT �L-_K va•�1 �`i�jeJ.J •`\ trio `e �� - F ` tfi]s tss9 n.o i v,, be SURVEYOR'S CERTIFICATION •WEHERE8YCERTIFVTO ELEANOR L.THOMAS 6 RAMA S. \Y RAO THAT THIS SURVEY WASP REPARED IIJ ACCORDANCE WLiH THE LADE g i•"` 9 .nA11 A OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STALE ASSOCIATION OF PROFESSIOWL LAND SURVEYORS. lea°{8.°i�``\ '�. 1 ,°' ] ,"t.'• �J` mac.F. �i'P Pp,O W,yo 0'P �v - @ ".J"" \ 'F1' '>F ;',,,,9 ��,,.„ tea' �� q-(r1(sh.L t,(!• y^ �cvcis- ,� HOARD W.YOURS,NY-- No. 9a �(AND 5 DANIEL A.WEAVER NYS.L.S.NO.SoM b'C V L •1 ^ fag \\4�j moo, c �•o,o bass �Oe)9 SURVEY FOR ELEANOR L. THOMAS di RAMA B. RAO' ' % tam at Orient,Town of Southold Suffolk County,New York a LEGEND \ CERTIFIED SURVEY tE CR CELLAR ENTRANCE l`\ C—tv Tax MaP D�s1Mt 1000 s ' 26 —02 �01 43.4 ' CA&F c CONCRETE MONUMENTFOUND ,xw�y'tF /' FIELD SURVEY COMPLETED MAR 18:2024 CMS =CONCRETE MONUMENT SET ``\ `\\ O O MAP PREPARED MAR.19:2024 CP =CONCRETE PAVEMENT EOP =E06EOF \�\ Record of Revisions PAVEMENT " OL ON PROPERTY LINE REVISION DATE RO =ROOF OVER WIF =WIRE FENCE ' Wsr =WOOD STAKEFOVND MARY-rnrt tc PA Tnaa WSS cWOOD STAKE SET =UTILITY POLE 4 ® =WELL \ S END OF DIRECTIOWDISTANCE - '' - 0 GAS MARK-OUT �. EtPCTRic MARK-OUT \ ``\ O K.1Prr� 40 0 20 40 Bo 120 TELEPHONEWATER MARK-OUT ` O s]Fy .. = \ Scale:V= 40' . ___,-____=SANITARY MARK-OUT `\\ 70B NO.20240J24' DW6.2o24 oD24_c! 1OFI t ' � DC APP RED AS NOTED NOTIFY BUILDING DEPARTMENT AT OCCUPANCY OIL F;OLLOWINGINSPECTO SFORTHE USE IS UNLAWFUL 1. FOUNDATION-TWO REOUIRED WITHOUT CERTIFICV FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING OF,0.000PANCY 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CgNDITIONS OF r OWN ZBA ELECTRICAL OWN PLANNING BOARD INSPECTION REQUIRED OWN TRUSTEES PC Fecifco Engineering PC WG Engineering Consulting 700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716 c solar@pacificoengineering.com February 5, 2025 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Thomas, Eleanor 1725 King Street Orient, NY 11957 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 22.0 ft 16.0 ft Pitch 34 degrees 23 degrees Roof rafter 2x8 2x8 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 7.1 ft 10.0 ft Table R802.4.1(1) max allowable 18.5 ft 18.5 ft Fastener Type SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, 4-1/2"length,2 per 4-1/2"length,2 per Allowable Fastener Capability 1788 lb 1788 lb Fastener Spacing,Zone 1 /2/3 64/32/64 in 48/64/48 in Point Pullout, lb,Zone 1 /2/3 159/96/191 lb 120/223/262 lb Zone Category 1 /2/3 1 /2/3 1 /2/3 Uplift Pressure Zone 1 /2/3 15/18/18 psf 15/21 /33 psf Exposure Category B Ground Snow Load, Pg 20 psf Wind Speed, 3 sec gust 130 mph array dead load 3.5 psf �®�N� �a load per attachment 37.1 lb ���QF! P4 :�o� The subject roof has 1 layer of roofing. a Panels mounted flush to roof no higher than 6 inches above roof surface. r— Ralph Pacifico, PE Professional Engineer �� 66182 Pacifico Engineering P.C. Ra � � ` meer Certificate#0018074 NY 0 1/31/28 GREENLOGIV ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#A: Total System Size:5.520kW Array Size:3.680kW 1 circuit of 8 on a 20A breaker Azimuth:220° Pitch:34° Monitoring System: EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking: IronRidge Panel:68.0"X 47.4" Array:22'9 1/8"X 7'11 1/8" x x x Surface:25'2"X 10'7" Legend: ® 8 RECAlpha Pure-RX460W 8 IQ8X Microlnverters ® Iron Ridge XR-100 Racking • 22 UniRac Drk Standoff 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:UniRac, IronRidge, REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: OF NEW/PA O .a fl! 9 r_� V� ©661 2 SIO�P�' Drawn By:MA Drawing#1 of 8 Date: 1/15/2025 REV:A Drawing Scale: 1/4"=1.0' iG�GREENLOGIC* ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#A: Total System Size:5.520kW Array Size:3.680kW 1 circuit of 8 on a 20A breaker Azimuth:220° Pitch:34' Monitoring System: EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking:I ronRidge Panel:68.0"X 47.4" Array:22'9 1/8"X 7'11 1/8" Surface:25'2"X 10'7" Legend: ® 8 REC Alpha Pure-RX460W 8 IQBX Microlnverters Iron Ridge XR-100 Racking • 22 UniRac Drk Standoff 0 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:UniRac, IronRidge,REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: V O PA r 066162 ��cl Drawn By:MA Drawing#2 of 8 • Date: 1/15/2025 REV:A ` Drawing Scale: 1/4"=1.0' G EENLOG1C'o ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#A: Total System Size:5.520kW Array Size:3.680kW 1 circuit of 8 on a 20A breaker Azimuth:220' Pitch:34° Monitoring System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: I ronRidge Panel:68.0"X 47.4" Array:22'9 1/8"X 7'11 1/8" 1 Surface:25'2"X 10'7" Legend: ® 8 REC Alpha Pure-RX46OW 8 IQBX Microlnverters ® Iron Ridge XR-100 Racking • 22 UniRac Drk Standoff 1 0 0 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used: UniRac, IronRidge, REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: OF NEPA w��� Y f 066182 � siOA Drawn By:MA Drawing#3 of 8 Date: 1/15/2025 REV:A Drawing Scale: 1/4"=1.0' GEELOGIC ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#B: Total System Size:5.520kW Array Size: 1.840kW 1 circuit of 4 on a 20A breaker Azimuth:220° Pitch:23° Monitoring System: EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking:I ronRidge Panel:68.0"X 47.4" Array:11'4 3/8"X 7'11 1/8" Surface:28'6"X 12'9" Legend: ® 4 REC Alpha Pure-RX 460W 4 IQBX Microlnverters ® Iron Ridge XR-100 Racking • 12 UniRac Drk Standoff 0 0 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used: UniRac, IronRidge, REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: PA 06618 Drawn By:MA Drawing#4 of 8 Date: 1/15/2025 1 REV:A Drawing Scale: 1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#B: Total System Size:5.520kW Array Size: 1.840kW 1 circuit of 4 on a 20A breaker Azimuth:220° Pitch:23° Monitoring System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking: Iron Ridge Panel:68.0"X 47.4" Array: 11'4 3/8"X 7'11 1/8" Surface:28'6"X 12'9" Legend: ® 4 REC Alpha Pure-RX460W 4 IQ8X Microlnverters — Iron Ridge XR-100 Racking • 12 UniRac Drk Standoff IL 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:UniRac, IronRidge, REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: OF Nripy� c I �® 066182 ��®+�ESSIO�A�'�• Drawn By: MA Drawing#5 of 8 Date: 1/15/2025 1 REV:A Drawing Scale: 1/4"=1.0' REENLOGICO ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 Surface#B: Total System Size:5.520kW Array Size: 1.840kW 1 circuit of 4 on a 20A breaker Azimuth:220' Pitch:23' Monitoring System: EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking:I ronRidge 2 Panel:68.0"X 47.4" Array: 11'4 3/8"X 7'11 1/8" Surface:28'6"X 12'9" Legend: ® 4 REC Alpha Pure-RX 460W 4 IQBX Microlnverters 2 — Iron Ridge XR-100 Racking • 12 UniRac Drk Standoff 0 W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used: UniRac, IronRidge, REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: PA 066182 Drawn By:MA Drawing#6 of 8 ' Date: 1/15/2025 REV:A Drawing Scale:1/4"=1.0' No Vent Pipes Will Be Covered By The Solar ArraX C*GREENLOGICe ENERGY Lege nd: GreenLogic,LLC Approved Thomas,Eleanor AR-Access Roof AP-Access pathway, 36" minimum width SVO—Setback at ridge 1725 King Street per R202 definitions per R324.6.1 as per R324.6.2.1 Orient, NY 11957 Total System Size:5.520kW 1 circuit of 8 on a 20A breaker 1 circuit of on a 20A breaker Azimuth:220° Monitoring System: EnPhase Panel/Array Specifications: Panel: REC460AA PURE-RX Racking:I ronRidge Panel:68.0"X 47.4" Surface:48'4"X 60'5" Legend: ® 12 REC Alpha Pure-RX460W 12 IQ8X Microlnverters AR — Iron Ridge XR-100 Racking • 34 UniRac Drk Standoff 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used: UniRac, IronRidge, REC, 4 REC 460W EnPhase Panels Added Roof load of PV System:2.32 sf AR Engineer/Architect Seal: Meter 8 REC 46OW �� 066182 . Panels SIOAQ�`�� Drawn By:MA Drawing#7 of 8 Date: 1/15/2025 REV:A Drawing Scale: 1/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Thomas, Eleanor 1725 King Street Orient, NY 11957 JOB MATERIAL LET Total System Size:5.520kW 1 circuit of 8 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:220' MaterlA Gst EQ�f. Ralfl Material List Q�IE . Monitoring System: EnPhase Panel/Array Specifications: UniRacrl)irkStandoffs 34 Panel: REC460AAPURE-RX Racking: I ronRidge 3f 1Gx4Y SS lagBdts 68 Panel:68.0"X 47.4" $f 16'Staidess Steel Writer 68 , Surface:48'4"X 60'5" 0ateyM20FlasWng(Black) 25 Legend: OateyIaO Flashing{Silved 9 12 REC Alpha Pure-RX460W ® 12 IQ8X Microlnverters Iron Ridge XR-100 Racking • 34 UniRac Drk Standoff 09 W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:UniRac, IronRidge,REC, EnPhase Added Roof load of PV System:2.32 sf Engineer/Architect Seal: 'MF NEC ® 066182 �� Drawn By:MA Drawing#8 of 8 Date: 1/15/2025 REV:A Drawing Scale: 1/16"=1.0' SOLAR'S MOST TRUSTED CC 4 I�Pll s AlA-""' x x V,;V, 7"K, Ilk b PURE g � x § r Ez 1 s -vpe B s x�� a "���• ��� a �:���•- s ��` x r +`t'°M r4 `� a ■■U CURRENT .A 'ak . . v� Q 450 -47D 25 . �� PR::; I REF ALPHA" PURE-RX 5ERIE5 tskREC OLA D � Measurements in Inches .# az x. ._. _ _. .. Cell Type 88 half-cut bifacial REC heterojunction cells, . -. with gaplesstechnology ,.. I { r 0.13 in.solar glass with.anti-reflective surface treatment. Glass in accordance with EN12150 Backsheet Highly resistant polymer(Black) 669 Iws Frame Anodized aluminum(Block) _ 4-part,4 bypass diodes, Junction Box IP68 rated,in accordance with IEC 62790 StaubliMC4PV-KBT4/KST4(12AWG) i r Connectors I . in'aacirdancewith IEC 62852.IP68 onlywhen connected) 01 12 AWG solar cable,66.9 in.+66.9 in. �l Cable in accordance withEN50618 oaos a, Dimensions 68 x 47 4x 1.2 in.(22.4ft2) . I ' + . ,. .. Weight 501bs os x3,oaotz a Origin"_ < ,''. ' Made in Singapore ? o EI ECfRiCA1 A fl PR p RE AA ur R � tTtF>IcAT1 arn Power Output-PM (W,) 450 460 470 IEC 61215:20211EC61730:2016;UL61730 ..Watt Class Stirling (W) 0/+10 0/+10 0/+10 ISO 11925-2 Igr itebllity(EN 13501-1:Class Ej IEC 62716 Ammonia Resistance $ Nominal Power Voltage-V,,,(V) 54.3 54.9 55.4 :IEC617Qi' SaltMist:(SM6) ° u IEC61215:2016 Hailstone Nominal Power Current-IM (A) 82.9' „ 8.38 8.49' D UL61730 •FireType2 0 Open Circuit Voltage-Voc(V) 65.1 65.3 65.6 ISO 14001;IS09001;1EC45001;IEC62941no In Shor6CircuitCurrent-Isc(A)' -',8.81 8.88. 895 Power Density(W/ftz) 20.1 20.5 21.0 UVE C E ❑ take 1n,ay , PanelEffidency(%) 21.6 " 22.1 22.6' imerbk a .,ywer- ' Power-.Output-P..(WO) 343, " 350 3S8 O Nominal Power Voltage-V.,M 51.2 51.7 52.2 z ;Nominal Power Current-IMF(A) `6.70 677 6186 Open Circuit Voltage-Voc(V) 61.3 61.6 61.8 Short Circuit Current-,Isc(A):, 7:11` 7.17 7.23 UUAi�IttN Y s Standard REC ProTrust Value sat standard tes:conditions(STC:air mass AM 1.5,irradiance 1000 W/m',temperature 77F(25'C)),based an a production sareadwah a tolerance of latex,Vn, I"t3% within onewatt class.Nominalmodule operalingtemperature(NMOTa;rmss AM 1.5,Irradumce800 W/m'.temperature 68°F(20,C).w,ndspeed 3.3 ft/s(i m/s))"Where xxx Installed'.by'an REC" - ind¢testhenominaipowerclass(P_)atSTCabove Certifie6Professional '- No Yes Yes' .a-0 System Size All <25 kW 25-500 kW Ak11UM RAT INGS ...z _.. 4RATUR Product Warranty20 25 25 Operational Temperature 40'F-185°F Nominal Module Operating (yrs) System Voltage - 1000 V Temperature 44`C f 2`C Power Warranty(yrs) 25 25 25 Maximum Test Load(front) +7000 Pa{14616/ftx) o Labor Warranty(yrs} 0; 25: 70 0 Temperature coefficient ofPMAx .; 0;24/o/K Maximum Test Load(rear)" 4000Pa(83.4 lb/ft=)' Temperature coefficient of Voc 0.24%/K Power in Year 1 98% 98% 98% N Max Series Fuse Rating 25 A Temperature coefficient of I_ 0.041%/K AnnuaGDegradatiori' 0.25% 0.25% 0.25% v :Max ReverseCurrertt 25A *The temperature coeffictents stated are linearalues Power in Year 25 92% 92% 92°% y `See Installation manual for mounting instructions Design load-Test load/1.5(safety factor) ". „ ,� The REC ProTrust Warranty is only available on panels purchased through an REC (VERY=INFORMATION Certified Solar Professional installer.Warranty conditions apply.See wwwrecgroup. w n ��,�,yy •<" "�„ ,_ ;•�.��..: cum for more de[ads N Panels per Pallet 33 In � Ranelsper4dffGP/h(gh "r 594`{ISPall ) t cube container ets U1fLlGN�`EIEHA Panels per 53 ft truck 792(24 Pallets) Available from: Typical low irradiance performance of module at STC: W _ _ E Imadiance(W/mx) Founded in 1996.REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable REC Solar PTE.LTD. ,� solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar 20Tuas 5outh Ave.14 ,'« REC panels it manufactures.Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Singapore637312 Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com ENPHASE. lWT�. t s r e , , , „ N 1 Q 8X M i c ro i nve rte r Easy to;nsta11 Our newest I08 Series Microinverters are the industry's first microgrid-forming*,software-defined -Lightweight and compact with plug= microinverters with split-phase power conversion capability to convert DC power to AC power and play connectors efficiently.The brain of the semiconductor-based microinverter is our proprietary application- i Power Ime eommun[catlon(PLC) specific integrated circuit(ASIC),which enables the microinverter to operate in grid-tied or between components off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Faster installation with simple two wire and superfast response times to changing loads and grid events,alleviating constraints on battery cabling., sizing for home energy systems. IQBX Microinverter is the latest addition to this family,designed to support PV modules with high High productivity and reliability output DC voltage and cell counts,such as 80-half-cut cells,88-half-cut cells and 96-cells. Pr'odLl*ces"power even when.fihe grid,is. •down More than one million cumulative hours oftesting< 25 Class II double-insulated enclosure Optimized'for the latest high powered P.V modules Part of the Enphase Energy System, IQ8 Series Microinverters redefine I08 Series Microinverters integrate with reliability standards with more than one Microgrid forming ' , the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies with the latest advanced gild Enphase App monitoring and analysis testing,enabling an industry-leading support software. limited warranty of up to 25 years. Remote automatic updates for the "R latest grid'requirements -. •.�Configura6letosupporta"wide,range;!. "' of;grid profiles , i Meets CA Rule 21(UL 1741 SA)and IEEE 1547 2018(UL 1741-SB) NOTE Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed "ids series Microinverterscannot be mixed with to the I08 Series Microinverters with as PV rapid shutdown equipment and previous ganaratlonsof Enphase microinverters(I07 integrated MC4 connectors. conform with regulations when Installed series;IQ6 Series,and'so and In the same system. according to the manufacturer's to Mtaoinveriers 5t;tp with defau`It setimgstnat< If1StfUCtlonS. meet North America's IEEE 1547 mtecconnection: standard requirements:Region specific adjustments may fie requested by. Authority Having Jurisdiction(AHJ)''o�Luiility representative;<- aocordirig to the IEEE 1547 mterconnectwn *Meets UL 1741 only when installed with IC System Controller 2 or 3. <standard.An IQ Gateway is regwrred ko makathese <�ct anges during installation ©2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,Io.and certain other marks listed at --- https;//anphase.cgm/trademark=usage=guidoifnos are trademarks of Enphase Energy,Inc,in the U.S.and other countries. Data subject to change. 108X-MC4-DSH-00185-3.0-EN-US-2024-02-12 IQ8X Microinverter INPUT DATA(Otr UNIT r: :r Commonly used module pai"rings W' 320-540 Module compatibility _ To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I.. Module compatibility can be checked at https://enphase.com/in-tallers/microin-vflrters/Calckilator MPPT voltage range v 43-60 Operating range V 25-79.5 Minimum and:maXimum start voltage 'U 30=79.5, Maximum input DC voltage V 79.5 Maximum continuous operating DC current A 10 Maximum input DC short-circuit current A 16 Maximum module 1. A 13 Overvoltage class DC port — I{ DC port backfeed current'.: mn 0 , Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per PV array configuration — branch circuit OUTPUT DATA r: :r r VAC IQ8X-;8d-M-aS,@2O8, Peak output power VA '384 366, Maximum continuous output power VA 380 360 Nominal grid voltage(L-L)- V 240,split-phase(L-L),180" 208 single-phase(L-L)120°" Minimum and maximum grid voltage Z V 211-264 183-229 Max.continuous output current A 1.58 1`73_ Nominal frequency Hz 60 Extended frequency'range. Hz+ 47=68 ' AC short circuit fault current over three cycles Arms 2.70 " Maximum units per 20 A(L-L)branch circuit;' — 10 9 Total harmonic distortion % `5 Overvoltage class AC port AC port backfeed current mA 18 Power.factorsetting — 1.0' Grid-tied power factor(adjustable) — 0.85 leading...0.85 lagging Peak efficiency 1 97.3 97.0' CEC weighted efficiency % 96.5 96.5 Nighttime power consumption mW' 26 12. DATA Ambient;temperature range -40°C to 65°C(-40°F to 149'F) Relative humidity range 4%to 100%(condensing) DC connector type 5tau61i MC4 Dimensions(H•W x D);Weight 212 mm(8.31 175 mm(6.9")•30.2 mm(1.2");1A kg(2.43 Ib) Cooling " Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class'ii double-insulated;corrosion-resistant polymeric enclosure` Environmental category;UV exposure rating NEMA Type 6;outdoor ' CA Rule 21(UL 1741-SA);UL 62109-1,JEEE 1547!2018(UL 1741-89),FCC Part 15'Cless B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. ' Certifications I This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and s C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when Installed according to the manufacturer's instructions: (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch In your area. 108X-MC4-DSH-00185-3.0-EN-US-2024-02-12 (4)1o8X Is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and Is,therefore,designed for single-phase operation only.Check with the local utility requirements if you wish to install single-phase inverters across three phases. r -., M IRONRIDGE XR Rail° Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing ,, enough to buckle a panel frame. XR Rails®are the structural backbone preventing these results. The resist uplift, �r P 9 Y P� protect against buckling and safely and efficiently transfer loads into the ' building structure. Their superiors spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. S. y� MN. 3i a � 4 'Y� Force-Stabilizing Curve *' Sloped roofs generate both vertical and lateral '�y forces on mounting rails which can cause them to L bend and twist.The curved shape of XR Rails@ is specially designed to increase strength in both 6 ¢ directions while resisting the twisting.This unique R feature ensures greater security during extreme weather and a longer system lifetime. 9 ra�r g�a . iw Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials £ R, XR Rails@ are Iron Ridge@ offers All XR Rails@ are made of 6000-series compatible with a range of tilt leg aluminum alloy,then protected with an options for flat anodized finish.Anodizing g prevents su FlashFoot@ and orface other pitched roof roof mounting and structural corrosion,while also providing ........ attachments. applications. a more attractive appearance. :�� +�sk+�a s s�x '^may, ��,� 3�' ... �� �y a�� 4 f� a ,��` a�. ���••�" g >y,,�`. a r " XR Rail° Family The XR RailO Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR ROO to match. g � A a z� ........ F XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability 10'spanning capability 12'spanning capability • Moderate load capability Heavy load capability Extreme load capability • Clear&black anodized finish Clear&black anodized finish Clear anodized finish • Internal splices available Internal splices available Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. d ,„ �" —.. 90 _ t rg � None ' 140 XR10 XR100 F � � * 0 -.N w 160E 90 120 �� 20 140 , � 1 0 { a # 16090 r � a � 30 h 160 iy 90 � l 40 ,�� x 160 sy 80 160 , 120 160 'Table is meant to b-,l a simplified span chart for conveying general rail capabilities.Use approved certification letters.for actual design guidance. ME W Ns a� P; x _. , fr �SF l : . . IRON RIDGE XR10019 Rail See Descr�ption / Length r / r Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in .66 Section Modulus(X-axis) 0.297 in .46 Moment of Inertia (X-a)ds) 0.390 in4 rp Moment of Inertia (Y-axis) 0.085 in Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 ......................_............._...........—........................_............... �— 1.25-- Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132'(11 Feet) 7.50 lbs. 6000-Series XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) Aluminum 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) 11.60 lbs. V1.11 Data Sheet Enphase Networking Enphase IQ Envoy The Enphase IQ Envoy"" communications gateway delivers solar production and energy consumption data to Enphase Enlighten"' monitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform for total energy management and integrates with the Enphase Ensemble"and the Enphase IQ Battery"' Smart Enables web-based monitoring. and control Bidirectional communications for remote upgrades •Supports power export limiting and zeroexport applications Simple • Easy system configuration using Enphase Installer Toolkit"mobile app • Flexible networking with Wi-Fi, Ethernet,or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty CERTIFIED To learn more about Enphase offerings,visit enphase.com S E. Enphase 6Q Envoy MODEL NUMBERS Enphase CQ Envby"` ' Enphase It Envoy commOnica#tons gateway with lrttegrated revenue gratle PV ems, r Aels � :.pInrcO1 240 ld� V IQ-AM ?fi uUCetsIO n r :-:. s r;btiroX z k cosuss. tinI ontng(' adap m on 'S d �- 11111 ; -x one?OOA contln`uous dte',production GT(current'fransforrner)„ . ACCESORIES(Order Seperately) Enphase Mobile Cahnect Plug and play^industrial grade cellular modem with data plan for systems up to 60 i,'.`CELLMODEM M1 (4G based LTE MI5 year data plan) mlcroinyerters (Avatiable7n the US Canada Mexico;Puerto Rtco and the US Virgin CELLMODEM M1� 4G�based ds LTE M115 years data plan) Jslan Where there is adequate cellular service in t_he instal[ation area) ,.�_,tip., 1e __ ,. _.. � .A a:. Consumption Monitoring CT Split-core consumption CTs enable whole home metering. CT-200-SPLIT Erlsamt�le Gomrnurications:l<itr Installed at the,iQ Envoy For comrriunications Wttli Enphese,Encharger storage COMMS KIT 01 f Wand Enphase EnpoWer"smart sWitellflncludes t(SB cablefi�rc rtnectidn to iQ �� x :Envoy or Enphase IQ Combiner aril allows wire lesscommgnrcaton with Enotiarge POWER REQUIREMENTS Power requirements120/240'VAC spi¢phase ' y Max 20 A overcucrent protection required piy Typical Power Consumption 5W CAPACITY 77 Nurnbof,h*roinverters poifed �s � � Up to 600 er � u, MECHANICAL DATA [7imensions(WxHxl�} 1 3 x 126 x 4 5 cm(8 4' x 1 8�) n �� '' , ,... '4..n�. ..._ ..de._�,n, .. ....... �, Weight 17.6 oz(498 g)., Ai�ibient temperature range s 40 to 65 C(40 to 149E)� 40��to 46 C(40 Ito 115 t-)tf installed ri do enclosure _ Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure. I Altitude , x To 2000 meters(6 560 feet) 0 Production CT Limited to 200A of continuous current/250A OCPD—72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) UL2808 certified for revenue grade metering Consumption CT for electrical services to 250A with parailel runs up;to 5004' kk Internal aperture measures 0.84 0 96 (21 33mm�xg2h 38rnin to support > l a aa.r M '� fr ra 3I0 THWN conductor �z UL280$certified,for useat sere ce entrance for services u to 50Uac INTERNET CONNECTION OPTIONS Integrated,Wi F _ n... _ Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile CELLMQDEM M1, (4G or GELLMODEM M1',B(4G) N,ot lncloded Note-that an z r Enphase Mobile�Connee)'ee}ltilar modem rsirequired;for all Ensemble Instaii' t` COMPLIANCE Compliance UL 6101b 1 , CANICSA G22 2 r10 610t01 r� � � 47 hR Vert 1S GJass B�CESO03� �C EC/EN 6101 0 1 2010 � ' x EN500ti5 1 EN61.000 4 5rEN61000 61,EN&1000 6 2 Metering ANSI C12 11 20acwcuracy class 0 5(PV production only) To learn more about Enphase offerings,visit enphase.com HAS E, CO 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,10 Envoy,.and other trademarks or service narr:.es are the trade- marks of Enphase Energy,Inc.Data subject to ch'ringe.O6-30-2021 v 5 -3 --------------NEW EQUIPMENT-------- ---------------------- EXISTING SERVICE 120/240, 1PH, 3W EMERGENCY AC GENERATOR ' PV-SA-1 A AC-COMBINER PANEL ' ® ® ® AC-CMB-1 I 200A KWH 41 ' nl . • • r� (PV LOADS ONLY) C ; e ---- — � I � PV-SA-2 �- I ® ® R-0-71 AC DISCONNECT (\J • • • 2 1 BKR-1 T " AC-DSC-2 a ---- a e — I I E AC DISCONNECT , i I I BKR-2 AC-DSC-1 fl I I , GRID-TIE ' I I LINE TAP II I I f ATS - N i ' �� I I 4 EGC IIA I I 1 '. I JUN 1 1 2025oil i I I f� ILl I I I IEGC IEGC MAIN , l I I I I I I �" l� 13uilding Department A 8 N I I I I Town o�Southold i I I I � I II I I I N I I I I I I13EGC (TYPICAL SYSTEM SCHEMATIC, I I I I I ' EXISTING AC FINAL INSTALLATION MAY VARY, I I I I I I DISTRIBUTION REQUIRES LOCAL AHJ I AND UTILITY APPROVAL) I I I I I i I EXISTING U------------•L---------------i---------J---- EGC #6 CU REVISIONS Rao, Rama & ¢�Pe GREENLOGIC® Thomas Eleanor & ENERGY 1725 King Street 2•) AS BUILT CONFIGURATION 1s�, v 1, 3 Q� ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 4 Drawing No:. THMS-3LD1 Revision: 2L Revised: 6/03/2025 r q SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 4.608 kW (PV) TOTAL KW RATING: (DC POWER) 5.520 kW (PV) QTY. COMPONENT SPECIFICATION REC BRAND, MODEL: REC460AA PURE-RX 12 PV MODULE: REC460AA PURE-RX 460 W DC(NOMINAL), EACH ENPHASE BRAND, MODEL: IQ8X-M-US 12 PV INVERTER: ENPHASE IQ8X-M-US 384 VA, 1.58 A, 240V AC, EACH NOTE: ENPHASE MODEL IQ8X INVERTER SETTINGS COMPLY WITH SECTION 7.5.2 AND 7.5.3 OF THE "PSEG LONG ISLAND'S SMART GRID SMALL GENERATOR INTERCONNECTION TECHNICAL REQUIREMENTS AND SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA'S DISTRIBUTION SYSTEM" REVISIONS Rao, Rama & GREENLOGICO Thomas Eleanor 1725 Kin Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 5/03/2025 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-1 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 4-INVERTERS REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-2 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 8-INVERTERS AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 60A, FUSED, NEMA-1, 1-PH, 3-WIRE, SERVICE RATED AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 25OV, 60A, NON-FUSED, NEMA-311, 1-PH, 3-WIRE AC-CMB-I AC COMBINER PANEL 250V, 60A, MAIN LUG, NEMA-1, 1-PH, 3-WIRE Rao, Rama & REVISIONS Thomas Eleanor C;R E E IV LOG IC® 1725 Kin Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 6/03/2025 V - ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,536 WATTS 211-264 VAC 15.72 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 15.72 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A NMB - 12 / 12 B NMB - 10 / 10 C THWN-2 1-1/4" PVC-40 4 / 4 D THWN-2 1-1/4" PVC-40 4 / 4 E THWN-2 1-1/4" NFC 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM REVISIONS Rao, Rama & Thomas Eleanor c*GREEN LOGIC® 1725 King Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 4 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 6/03/2025 C E It 4t E -*� f D 6,3 - - - - - NEW EQUIPMENT --------------- -- JU� Z ZO25 EXISTING SERVICE 3W EMERGENCY AC GENERATOR ' PV-SA-1 A AC-COMBINER PANEL ' ® 17M7 AC-CMB-1 Building Department I 200A KWH (PV LOADS ONLY) Town of Southold � I : PV-SA-2 I ® . . . ® ® AC DISCONNECT N . . . 2 � BKR-, B AC-DSC-2 le ---- B o E AC DISCONNECT , ' I I BKR-2 AC-DSC-1 II I , GRID-TIE ' I I LINE TAP II II II Z� I ATS IIN FUSM II II � ' I I EGC I I II I I LI IEGC IEGC ' 200A I I I I MAN }� A B N I II I I I I I II I I I I N I I I I I I I EGC II I I I (TYPICAL SYSTEM SCHEMATIC, I I I I I ' EXISTING AC I FINAL INSTALLATION MAY VARY, I I I I I I DISTRIBUTION I REQUIRES LOCAL AHJ AND UTILITY APPROVAL) EXISTING I V-----------=L---------------L--------J---- EGC #6 CU --------------------------------------------------------�- Rao Rama & REVISIONS Thomas Eleanor ¢�P�� ' ILA GREENLOGIC® 1725 King Street *� ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION 0 163��y0 Pagel of 4 Drawing No: THMS-3LD1 Revision: 2_/ Revised: 6/03/2025 J SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 4.608 kW (PV) TOTAL KW RATING: (DC POWER) 5.520 kW (PV) QTY. COMPONENT SPECIFICATION REC BRAND, MODEL: REC460AA PURE-RX 12 PV MODULE: REC460AA PURE-RX 460 W DC (NOMINAL), EACH ENPHASE BRAND, MODEL: IQ8X-M-US 12 PV INVERTER: ENPHASE IQ8X-M-US 384 VA, 1.58 A, 240V AC, EACH NOTE: ENPHASE MODEL IQ8X INVERTER SETTINGS COMPLY WITH SECTION 7.5.2 AND 7.5.3 OF THE "PSEG LONG ISLAND'S SMART GRID SMALL GENERATOR INTERCONNECTION TECHNICAL REQUIREMENTS AND SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH-LIPA'S DISTRIBUTION SYSTEM" REVISIONS Rao, Rama & Thomas Eleanor G R E N LOG IC® 1725 Kin Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 5/03/2025 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-1 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 4-INVERTERS REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-2 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 8-INVERTERS AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, FUSED, NEMA-1, 1-PH, 3-WIRE, SERVICE RATED AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 250V, 60A, NON-FUSED, NEMA-311, 1-PH, 3-WIRE AC-CMB-1 AC COMBINER PANEL 250V, 60A, MAIN LUG, NEMA-1, 1-PH, 3-WIRE [Rao, Rama & REVISIONS Thomas Eleanor C+ R E E N LOGIC° 1725 King Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 6/03/2025 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,536 WATTS 211-264 VAC 15.72 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 15.72 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A NMB - 12 / 12 B NMB - 10 / 10 C THWN-2 1-1/4" PVC-40 4 / 4 D THWN-2 1-1/4" PVC-40 4 / 4 E THWN-2 1-1/4" NFC 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER,MINIMUM REVISIONS Rao, Rama & Thomas Eleanor ct G R E EiV LOG IC® 1725 Kin Street ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 4 of 4 Drawing No: THMS-3LD1 Revision: 2 Revised: 6/03/2025 --------------NEW EQUIPMENT------------------------------ EXISTING SERVICE 120/240, 1PH, 3W EMERGENCY AC GENERATOR ' PV—SA-1 A AC—COMBINER PANEL ' ® 17M7 AC—CMB-1 I 200A KWH N (PV LOADS ONLY) C' ----- B e � I � � PV—SA-2 B I I ® AC DISCONNECT BKR-1 B AC—DSC-2 e _ —, j D I E I I AC DISCONNECT , ' II BKR-2 AC—DSC-1 II I I , GRID—TIE ' I I LINE TAP II II II i I I I ATS N FU= EGC II I I 11 II I I I iEGC iEGC ' 2200N 1 " I I I I I I Ltd C, -0 N !� A A B N p II I I ICL II I I I ►L loco II I I I I z 0 N Z 9:1I I I I I EGC II I I I (TYPICAL srsrEM scHEMAnc, I I I I I ' EXISTING AC I �� FINAL INSTALLATION MAY VARY, I I I I I I DISTRIBUTION 1 --=---'1�-7 REQUIRES LOCAL AHJ AND lJi1LlTY APPROVAL) EXISTING U------------.----------------L----------�---- EGC #6 CU -- L _� L------=------------------------------------------- -- --�;-- • Ep Aq Rao, Rama & REVISIONS 3•�Sr. "� - � �• � GREEI�LOGIC° Thomas Eleanor 1725 King Street 3.)CORRECTED AS BUILT CONFIGURATION Q� ENERGY 2.) AS BUILT CONFIGURATION r* �2T.633 �O ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION i T�OF'NE`� Page 1 of 4 Drawing No: THMS-3LD1 Revision: 3 Revised: 6/18/2025 I SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 4.608 kW (PV) TOTAL KW RATING: (DC POWER) 5.520 kW (PV) QTY. COMPONENT SPECIFICATION REC BRAND, MODEL: REC460AA PURE-RX 12 PV MODULE: REC460AA PURE-RX 460 W DC(NOMINAL), EACH � w ENPHASE BRAND, MODEL: IQ8X-M-US r� c�v 0 12 PV INVERTER: ENPHASE IQ8X-M-US o ro 384 VA, 1.58 A, 240V AC, EACH Ln � 00 L s t� NOTE: ENPHASE MODEL IQ8X INVERTER SETTINGS COMPLY WITH SECTION 7.5.2 AND 7.5.3 OF THE "PSEG LONG ISLAND'S SMART GRID SMALL GENERATOR INTERCONNECTION TECHNICAL REQUIREMENTS AND SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA'S DISTRIBUTION SYSTEM" Rao, Rama & REVISIONS ¢�;� GREI Thomas Eleanor NLOGICO 1725 King Street 3.)CORRECTED AS BUILT CONFIGURATION — ENERGY _ 2.) AS BUILT CONFIGURATION ay Q� ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 4 Drawing No: THMS-3LD1 Revision: 3 Revised: 6/18/2025 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-1 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 4-INVERTERS REC SOLAR, MODEL: REC460AA PURE-RX, PV-SA-2 PHOTOVOLTAIC SUB-ARRAY INVERTER: ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 8-INVERTERS AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, FUSED, NEMA-1, 1-PH, 3-WIRE, SERVICE RATED AC-DSC-2 AC DISCONNECT SWITCH (EXTERIOR) 250V, 60A, NON-FUSED, NEMA-311, 1-PH, 3-WIRE AC-CMB-1 AC COMBINER PANEL 25OV, 60A, MAIN LUG, NEMA-1, 1-PH, 3-WIRE L-'-- p o N t co RjLg z� REVISIONS Rao, Rama & ��® Thomas Eleanorct 1725 King Street 3.)CORRECTED AS BUILT CONFIGURATION ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 4 Drawing No: THMS-3LD1 Revision: 3 Revised: 6/18/2025 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,536 WATTS 211-264 VAC 15.72 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 15.72 A AC '240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG.- / EGC A NMB - 12 / 12 B NMB - 10 / 10 C THWN-2 1" PVC-40&1" LFNC 6 / 6 I D THWN-2 3/4" LFC&1" PVC-40 6 / 6 LM , E THWN-2 1" LFNC 6 / 6 0 cv �. co 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. CC a 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTSr 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM REVISIONS pED Aq Rao, Rama & 3. T Thomas Eleanor L®GI 1725 King Street 3.)CORRECTED AS BUILT CONFIGURATION * ENERGY 2.) AS BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 'I•) INITIAL SUBMITTAL WITH APPLICATION Orient, NY 11957 r b21G33 yOQ Page 4 of 4 Drawing No: THMS-3LD1 Revision: 3 Revised: 6/18/2025