Loading...
HomeMy WebLinkAbout51657-Z OF SOUT�O� Town of Southold * * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46125 Date: 04/25/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 475 Rambler Rd Southold, NY 11971 Sec/Block/Lot: 88.-5-32 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 61/02/2025 Pursuant to which Building Permit No. 51657 and dated: 02/19/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Peter Cvikevich ,Nobuko Tange Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51657 3/28/2025 PLUMBERS CERTIFICATION: Autho 'zed Ognature �o��,oF,o�ryo(o TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51657 Date: 02/19/2025 Permission is hereby granted to: Peter Cvikevich 475 Rambler Rd Southold, NY 11971 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 475 Rambler Rd, Southold, NY 11971 SCTM#88.-5-32 Pursuant to application dated 01/02/2025 and approved by the Building Inspector. To expire on 02/19/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 --- --------- -rig Inspector OF SOUr��l - � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Peter Cvikevich Address: 475 Rambler Rd City: Southold St: NY Zip: 11971 Building Permit#: 51657 section: 88 Block: 5 Lot: 32 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: SunRun License No: 33878ME SITE DETAILS Office Use Only Indoor P-11 Basement 1- Service r Solar Fv-1 Outdoor W- 1st Floor Pool F, Spa r Renovation F 2nd Floor (— Hot Tub r Generator (- Survey Attic r Garage rl Battery Storage r INVENTORY Service 1 ph r Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph F Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 17.22kW Roof Nmounted PV Solar Energy System w/ (42) MLG10 410W Modules, SE570OH-USMN Inverter & SE7600H-USMN' Inverter, 70A Fused Disco, PV Load Center Notes: Solar Inspector Signature: X Date: March 28, 2025 Sean Devlin Electrical Inspector sean.devlinCaD-town.southold.ny.us 475Ramblersolar hO��pF SOUIyOIo -1 -7 t�/ � # # Tb% OF SOUTHOLD. BUILDING`d DEPT. co 631--765-1802 INSPECTION [ ] '.FOUNDATION,1ST/ REBAR [ ] ROUGH PLBG. . [ ] FOUNDATION 2ND [ .] lNSULATION/CAULKING [ ] FRAMING/STRAPPING [ } FINAL [ , ] FIREPLACE & CHIMNEY [ ] 'FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ . ] PRE C/O [ ] RENTAL REMARKS: < ,� ke �41 DATE - INSPECTOR OF SOUK°�G # # -TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 ECT1-0 NINSP [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [dFINAL �Q [ ] FIREPLACE & CHIMNEY [ ] FIRE.SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS. I V D� Vie. c.a DATE INSPECTOR {' APR 4 2025 March 17, 2025 Subject: Post Installation Approval Letter Job Number: 216R-475CVIK Client:PETER CVIKEVICH Address:475 Rambler Rd Southold NY USA 11971 Building Permit: 51657 To Whom It May Concern The purpose of the review was to verify the installation is in conformance with the approved plan set and that any potential modifications from those plans meet the intent of the approved plan set. I certify that the PV racking system's attachments have been observed to be installed in conformance with the approved plan set. The installation complies with the code provisions listed below. -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS • Basic Wind Speed V=128 mph,Exposure Category B, • Ground Snow Load=25 Psf Sincerely, Exp.date j 4/30/202 OF NEB . SyEY KAgrJq Y0 �;,, Digitally signed by ,,[�� lumphrey Kariuki m �Dat,e.:-_2025.03.17 95450 ��� 13:13 47 -04'00' ROFES 10VA 6755 Business Parkway, Suite 210 Elkridge,MD 21075 1 (667) 686-8469 1 hkariuki@gmail.com Mejia, Evelin From: Jen Maher <jen.maher@sunrun.com> Sent: Monday, April 14, 2025 9:27 AM To: Mejia, Evelin Subject: Re:47S Rambler Rd Southold - SUNRUN Hi Evelin, Would you kindly pass this photo along to Sean, he may have missed it because they're stacked..? Thank you I �G r 2�U q 70 06 �.�. . On Mon, Apr 14, 2025 at 9:07 AM Mejia, Evelin<evelinm cr,southoldtownny.gou> wrote: Hi Jen, Sean reviewed the photos- his note reads" plan has 2 inverters-only saw one" 1 t + I I I ' ' � oAV FNfiS5C41ENT - -40 SENT (. � QApV EFTFNCIA VGN��Ci I ■JSEWCi ON I ■ .. •FF �t 1p aw OBNC . �'t+'f-I' r .I a a I y �,�}',,/ 1� ��, � ,fi��y �1, � •�' 1 `\a ��' �r _ v10 .. 1 "r 1 f ti FIELD INSPECTION REPORT DATE COMMENTS -o re FOUNDATION (1ST) — - — ---- ------ ------------------------------------ — ----— --- - --------- —.- —© C FOUNDATION (2ND) --- z O ROUGH FRAMING& PLUMBING t -- N INSULATION PER N.Y. -- -- ■-3 STATE ENERGY CODE -- _ • 3-31�- os ins � Cep tic '� . FINAL - - --- ADDITIONAL COMMENTS `reC " - -=- ----- - c o rn ty�-! r� UFFOLt TOWN OF SOUTHOLD—BUILDING:DEPARTMENT ' Town Hall Annex 54375 Main Road P. O. Box 1179 Southold;NY 11971-0959 yt T Telephone (631) 765-1802 Fax (631) 765=9502 htWs://www.goutholdtomm-goes Date Received APPLICATIO.NTOR BUILDING.PERMIT For Office Use Only nD E C E O L'! E PERMIT Nb': ✓ Building Inspector: JA N - 2 2025 777 Applications and forms must be filled out in their entirety Incomplete applications will not be accepted..;Where the Applicant is not the owner,an Building®apartment Owner's'Authorization form(Page 2)shall be:iompleted. Town of Southold Date: �.a'-� Ci'2, OWNERS)OF PROPERTY: ame: o �� r C 1/� I� ✓ C�j SCTM#1000- 619� -- 40-05" 06-vim C5c� v hJ / . .. Project Address: o Phone#: _. ( ' o? '. I .Email: ���e�- C✓r /�� hv�.�:G� . Mailing Address: ,� �: iJ „CONTACT PERSON:. . . . . . Name: lctie% a. CJi! . -Mailing Address: CCA 4T/a G1C G✓ e:6:�b_t1c _ �_ i.�S9 Phone#: — Email: Ivy DESIGN'PROFESSIONAL INFORMATION: Name:.. k h�� , LUt r Ui� - Mailing Address: ` Phone#: 169&40_ Email: Cc�>U./�/. � CONTRACTOR INFORMATION: :Name: Mailing Address: Phone#: _ 5Email• DESCRIPTION:OF.PROPOSED CONSTRUCTION; ; El New Structuee.:❑Addition ❑Alteration ORe air ❑Demolition Estimated Cost of.Profect: Other C 501.E ..... .. . WIII the lot be re-graded? ❑Yes o Will excess fill be removed from premises? El Yes ,. . J. f ; PROPERTY INFORMdTION l r. Existing use of property: -Intended use of property:. - - - - - _ - Zone or use district in which premises is si. .ated: Are.there any covenants and restrictions with respectto . this property? ❑Yes El No IF YES, PROVIDE A COPY. beck 46x After Reading The owner/wntractor/design professional is respohsible:forall drainage and storm wateP issues as provided by Chapter 236"6f the Town Code APPLICATION IS HEREBY MADE to the Building DC.epartment far the issuance of_a,Building Permit"pursuant to the Building Zone': ... iOrdinanoe of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of•buildings„ In • addkions,alterations or for removal or demolition as herein described The applicant agrees to comply with all applicable laws;ordinaeces,:building Bode, r housing code and:regulatlons and to admit authorized inspectors on premises.and to buildmg(s)fo"r necessaryanspections false statements made herein are punishable' a Class A inisdemeanor,pursuant to Section 21Q 45�f the New York State Penal law Application Submitted By(print name): EfXuoifiarizied Agent ❑Owner :Signature of Applicant: Date: STATE OF NEW YORK} S: COUNTY-OF ) . .:1-1164e� (C.n: (��i being;duiy sworn,deposes and.says that(s)he is (Name of.individual signing contract) above named, • (S)he.is the (Cbhtracto ,Agent;Corporate Officer,etc.) of said.owner or owners, and:is.duly authorized.to.perform or have performed the said work:and to make and:fiie:this. application;that all statements contained in this application are true to the best of his/her knowledge:and belief, and that the work will be;performed in the manner set forth ihithe:application file therewith. Sworn`before me this • N. 2CQt��z 2 day of y . Notapouibilic DAVID J MACKEY Notary Public; State of•New York R®g No 01MA6381235 PROPERTY OWNER AUTHORIZATION Qualified in Nassau County, Commission Expires October 01 :2026 (Where the applicant is not the owner) I, V :resrdin at K75 Crn. � ' �Pl" �C/ � l o ap.pdo hereby authoriz L1/� ,� .I .:o. n.. my behalf to the Town of•Southold Building-Department for approval as described herein. G j / • Owner's Signature Date Print Owner's Name 2 . : o��SufFot��, BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 w ^ Southold, New York 11971-0959 o4,- � Telephone (631) 765-1802 - FAX (631) 765-9502 iamesha-southoldtownny.gov- seand(@-southoldtownny.Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: j rJ .2 1 c��-t�C3� Electrician's Name* UL%aS License No.: / 3 �7 Elec. email: /-I e,1n;-1S ✓4 Elec. Phone No: /- r 6 1<, L3'i request an email copy of Certificate of Compliance Elec. Address.: 7 (?c��r`o_ Q,%Q 2cJc.1L �c,�e�-,�-b01- L/ 1/5-96 JOB SITE INFORMATION (All Information Required) Name: Address: ?S 12a-,61e- 2c:G da-z-1-he) ld AiV 119171 Cross Street: Phone No.: Bldg.Permit#: (o S� email: Tax Map District: 1000 Section: �rl Block: 6� Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): l n s 14•a- t l��7,0,n -1P /'cvc)-P /nOLr-7- d cS died- p cne-lS- ��ia� 17• �7a2C� 1L� Square Footage: Circle All That Apply: Is job ready for inspection?: ElYES�O ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES �NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 n2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION .3. KmJ APPRO ED AS NOTED FEE eY: NOTIFY BUILDINGDEPARTMENrAT OCCUPANCY OR TO 4PM FOR THE OLLOWIING INSS1802 MP CCTIONS-' USE IS UNLAWFUL 1. FOUNDATION-FOR POURED CONOCRETE REQUIRED- WITHOUT CERTIFICA7 a NSULATIONAMING&PLUMBING OF OCCUPANCY 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND C DITIONS OF ELECTRICAL SOMOLD OWN ZBA INSPECTION REQUIRED SOMO TOWN PLANNING BOARD LD TOWN TRUSTEES N,Y EC OLD HPC December 30,2024 RE: CERTIFICATION LETTER Project Address: PETER CVIKEVICH RESIDENCE 475 RAMBLER RD SOUTHOLD,NY,11971 Design Criteria: -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=II -Wind Speed=128 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=25 psf -ROOF AR-01:2 x 6 @ 16"OC,Roof DL=8 psf,Roof LUSL=20 psf(Non-PV),Roof LUSL=16.1 psf(PV) -ROOF AR-02:2 x 6 @ 16"OC,Roof DL=8 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=15.4 psf(PV) -ROOF AR-03:2 x 10 @ 16"OC,Roof DL=9 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=15.4 psf(PV) -ROOF AR-04:2 x 10 @ 16"OC,Roof DL=9 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=15.4 psf(PV) -ROOF AR-05&AR-06:2 x 10 @ 16"OC,Roof DL=12 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=15.1 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, Exp.date 1 4/30/20�P���FNN�yO ;i Digitally signed by R q E ✓ -p ti * =Q� Humphrey Kariuki m 'y D=at.e::,2024.12.30 � S1 SSION 06:57 14 -05'00' �OFEP� 6755 Business Parkway,Suite 210 Elkridge,MD 21075 (667)686-8469 1 hkariuki@gmail.com pg 1 of 17 `t SHEET INDEX SCOPE OF WORK GENERAL NOTES PAGE N DESCRIPTION SYSTEM SIZE:17220W DC,13360W AC •ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET MODULES:(42)HANWHA Q-CELLS:O.PEAK DUO BLK WITH 2O18 IRC/IBC/IEBC,7-16 ASCE&2018 NDS,MUNICIPAL CODE,AND ALL Exp.date ML-G10+410 MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. 4/30/202 A PV-3.0 LAYOUTA ( ) S OF NSA, PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •(P )0 SE5700H-USMN, 1 SOLAREDGE TECHNOLOGIES: •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. 5 RE� KA 'A� SE7600H-USMN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY * �Q PV-3.1 LAYOUT B •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP TO GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. J ?% FRAMING,SEE DETAIL SNR-DC-00436 MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. PV 4.0 ELECTRICAL O •EXISTING BACK-UP GENERATOR INSTALLED. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-5.0 SIGNAGE •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. -- SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II 95450 MODULES,ARE CLASS A FIRE RATED. tp •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL �OFESS1o1�P� CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. `! t, . 11.2 AMPS MODULE SHORT CIRCUIT CURRENT. } 14 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. D I g I Li�V S I g.n edi by,Humphrey Kariuki Date: 2024.12.30 06:57:32 -05'00' sunrun 00825-ME ABBREVIATIONS VICINITY MAP 0 825-M RODK ROAD,VESTBUgY,NY 115M A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CUSTOMER RESIDENCE: 4�— a%ham.. PETER CVIKEVICH ! - '------.___ua-- AZIM AZIMUTH 475 RAMBLER RD,SOUTHOLD, COMP COMPOSITION �`�.�• f� ' NY,11971 DC DIRECT CURRENT g d d f 8 (E) EXISTING ,y i. - !` TEL.(100 088-0-0 � � _' APN:1000-OBB-00-05-00-032-000 ESS ENERGYSTORAGESYSTEM PROJECT NUMBER: MSP MAIN SERVICE PANEL _ , _ �• 216R-475CVIK (N) NEW PRE-FAB PREFABRICATED /� DESIGNER: (415)580-6920 ex3 JOHN PAUL TECSON F POUNDS PER PV PHOTOVOLTAIC OUAREFOOT Nn\. SHEET RSD RAPID SHUTDOWN DEVICE COVER SHEET/ _ TL TRANSFORMERLESS i REV:A 12/30/2024 V VOLTS PAGE IN WATTS � ' _ .� PV-1.0 SITE PLAN-SCALE=1116"=1'-0" SE AMP SITE PLAN DETAIL-SCALE=1/64"=V-0" 0� LC INV INV (N)ARRAY AR-06 (E)DRIVEWAY (E)POOL � �P4 m� (E)POOL a Eap.date ROOF PATHWAYS 4� `_ \ 4/30/20 PEE pF NetV Y (N)ARRAY AR-04� (3 TYP) •` •�:`�.,. -...., rp Y KAIy4 u Q FIRE SETBACKS (N)ARRAY AR-03 (18"TYP) (E)RESIDENCE (E)FENCE (E)GATE ..Z ,�.... !' �O�SSIONP�, (N)ARRAY AR-05 (E)GAZEBO j (E)STORAGE s u n r u n ROOF PATHWAYS (3'TYP) \� ARRAY TRUE PV AREA PITCH AZIM (SQFT) 00825-ME AR-01 20° 204° 84.5 1P VOLER K-D•WESTBURY•NY-0 PRWEODSSW.SCB1 (N)ARRAY AR-01 AR-02 22° 113° 232.5 Fq1`-- AR-03 22° 293° 126.8 CUSTOMER RESIDENCE: AR-04 22° 294° 147.9 PETER CVIKEVICH (N)ARRAY AR-02 475 RAMBLER RD,SOUTHOLD, AR-05 23° 114° 126.8 NY,11971 AR-06 1 23° 25° 169.1 TEL.(516)242-0628 SOLAR APN:1000-088-00-05-00-032-000 MODULES PROJECT NUMBER: 216R-475CVIK LEGEND AC ❑ELECTRIC VEHICLE MICROGRID ❑GROUNDING DESIGNER: (415)580-6920 ex3 SM SUNRUN METER 0 AC DISCONNECT(S) EV MD -L 6CgLE:NTS SUPPLY EQUPMENT INTERCONNECT DEVICE ELECTRODE JOHN PAUL TECSON NOTE:NOT ALL ITEMS IN LEGEND DC + ENERGY STORAGE F 7 INTERIOR EQUIPMENT SNR MOUNT WLLAPPEAR IN SITE PLAN pM DEDICATED PV METER DC DISCONNECT(S) ��' METER ADAPTER SHEET SYSTEM L J SHOWN AS DASHED SNR MOUNT 8 SKIRT SITE PLAN SE SERVICE ENTRANCE SP SUB-PANEL INV INVERTER(S) AM ACREL METER BI BACKUP INTERFACE O VMESUNICATION BG BACKUP GATEWAY REV:A 12130l2024 MP MAIN PANEL LC PV LOAD CENTER sEM SOLAREDGE METER CB IQ COMBINER BOX BP BACKUP LOADS PANEL H STORAGEO ASYSTEM(SS) S TRANSFER SWITCH PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-11" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-1" 4'-0" 1'-10" STAGGERED 128 MPH 3-SEC GUST. SNR-DC-00436 FASTENERS: (1)5/16"DIA S.S.LAG SCREW:2.5" RL UNIVERSAL,SPEEDSEAL TRACK ON MIN EMBEDMENT INTO FRAMING AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 15'-10" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-1" 4'-0" T-11" STAGGERED SNR-DC-00436 RL UNIVERSAL,SPEEDSEAL TRACK ON AR-03 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 13'-11" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-1" 4'-0" 1'-111, STAGGERED SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'4" AZIM:204° AZIM:113° PITCH:20° PITCH:22° 3'-6" 12'-5" _8'_9„_ 14'-6" 4. Exp.date 10" 4/30/20 OF NEW J 5'4"TYP - r = - 5'-4"TYP - 17'-10" 0 ` ° Ix 13'-2" to 10'_5" 02 96450 �OFESS101A - 4'TYP - 2,$„ 2 sunrun -.�3',6" —6'-2"— 3'-1" - 0OB25-ME 1]l CAMIAOIIE ROCK ROAD,WE URY,W1159D PlroREBO5.5aD.5aB) FAX B45.MB.M1 D3-AR-03-SCALE:1/8"=1'-0" INSTALLERS SHALL NOTIFY CUSTOMER RESIDENCE: AZIM:293° 3'- —6'-2"— -1' ENGINEER OF ANY POTENTIAL PITCH:22° STRUCTURAL ISSUES OBSERVED PETER CVIKEVICH114475 RAMBLER RD,SOUTHOLD, 1'-8" PRIOR TO PROCEEDING W/ INSTALLATION. NY,11971 IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF TEL(516)242-0628 ANY ROOF PLANE EDGES(EXCEPT APN:1000-088-00-95-00-032-000 VALLEYS),THEN ATTACHMENTS PROJECT NUMBER: 13'-11" NEED TO BE ADDED AND 216R-475CVIK 5'4"TYP - OVERHANG REDUCED WITHIN THE 12"BOUNDARY REGION ONLY AS DESIGNER: (415)580-6920 ex3 FOLLOWS: JOHN PAUL TECSON P"ALLOWABLE ATTACHMENT SACING INDICATED ON PLANS TO SHEET BE REDUCED BY 50 k. LAYOUT A 1'-2" —I "ALLOWABLE OVERHANG { INDICATED ON PLANS TO BE 1/5TH REV:A 12/30/2024 35' 17'-3" —6'-11"— OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-04 COMP SHINGLE-RLU 2-Story 2X10 RAFTERS 10'-7" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 128 MPH 3-SEC GUST. SNR-DC-00436 FASTENERS: RL UNIVERSAL,SPEEDSEAL TRACK ON (1)5/16"DIA S.S.LAG SCREW:2.5" MIN EMBEDMENT INTO FRAMING AR-05 COMP SHINGLE-RLU 2-Story 2X10 RAFTERS 10'-7" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-l" 4'-0" 2'-0" STAGGERED SNR-DC-00436 RL UNIVERSAL,SPEEDSEAL TRACK ON AR-06 COMP SHINGLE-RLU 2-Story 2X10 RAFTERS 10'-11" 16" COMP TO FRAMING,SEE DETAIL 5'-4" 2'-l" 4'-0" 2'-0" STAGGERED SNR-DC-00436 D4-AR-04-SCALE:1/8"=1'-0" DS-AR-05-SCALE:1/8"=1'-0" AZIM:294° AZIM:114' PITCH:22' PITCH:23' i 9"-{ 13'-11" 16'-10" } 4/30/2 to Y vso/zo W a OF NF ❑ m � 2� - 4'TYP - I - 4'TYP - 95450 ROSSIONP� sunrun 00825-ME 111 CPMWLLE ROLK ROAD,WESTBURV,NV 11590 PlbNE 805.590.SG0] FA%BQ36B.A1ZL DB-AR-08-SCALE:1/8"=1'-0" AZIM:25' INSTALLERS SHALL NOTIFY CUSTOMER RESIDENCE: PITCH:23' ENGINEER OF ANY POTENTIAL PETER CVIKEVICH STRUCTURAL ISSUES OBSERVED 4 e' 22'5 475 RAMBLER RD,SOUTHOLD, " PRIOR TO PROCEEDING W/ ^ INSTALLATION. NY,11971 RAM lLL l�l�L �1 V-91 IF ARRAY(EXCLUDING SKIRT)IS TEL.(516)242-0628 WITHIN 12"BOUNDARY REGION OF 5'-4"TYP _ ANY ROOF PLANE EDGES(EXCEPT APN:1000-088-00-05-00-032-000 VALLEYS),THEN ATTACHMENTS PROJECT NUMBER: NEED TO BE ADDED AND 216R-475CVIK 9 8° OVERHANG REDUCED WITHIN THE 12"BOUNDARY REGION ONLY AS DESIGNER: (415)580-6920 ex3 .41 'TYP - FOLLOWS: JOHN PAUL TECSON "ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO SHEET BE REDUCED BY 50%. LAYOUT-B —ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH REV:A 12/30/2024 OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.1 1201240 VAC SINGLE PHASE SERVICE METER#: NOTE:TOTAL PV BACKFEED=70A OPSEGLI 80618280 USED FOR INTERCONNECTION �F OF NEWS, ACCOUNTM CALCULATIONS SOLAREDGETECHNOLOGIES: �tQ 0p,1C KA►.�4 ;8 UTILITY 9630747263 SE570OH-USMN 0Q GRID 5760 WATT INVERTER JUNCTION BOX PV MODULES SUPPLY SIDE TAP 28 OR EQUIVALENT 1a HANWHA Q-CELLS:Q.PEAK DUO BLK s ^�� 4so ML-G10+410W(17)MODULESEXISTING OPTIMIZERS WIRED IN: � 106286GEN (N)100A PV LOAD (1)SERIES OF(9)OPTIMIZERS <^p TRANSFER 4 CENTER LOAD RATED OC DISCONNECT (1)SERIES OF(8)OPTIMIZERSee��as �FESSISWITCH WITH AFCI,RAPID SHUTDOWN LAREDGE POWER OPTIMIZERS 8/31/20 COMPLIANT U650 (N)LOCKABLE 3a EXISTING } 200A BLADE TYPE D La�l\s i - n ed C MAIN BREAKER FUSEDAC SOLAREDGETECHNOLOGIES: g y sh 200 A DISCONNECT SE7600H-USMN 7 .l 1 MAIN BUS 7600 WATT INVERTER JUNCTION BOX PV MODULES by Baba k i� 4 3b 2b OR EQUIVALENT EXISTING 1b HANWHA Q-CELLS:Q.PEAK DUO BLK 200A MAIN — �• � (25)MODULES i<avlani --- OPTIMIZERS WIRED IN: FACILITY PANEL 70A FUSES (1)SERIES OF(13)OPTIMIZERS Date: LOADS SQUARE D (N)30A PV BREAKER(A) LOAD RATED DC DISCONNECT (1)SERIES OF(12)OPTIMIZERS D223NRB (N)40A PV BREAKER(B) WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,100A COMPLIANT U650 2024.12.30 1201240VAC 06:58:30 -05'00' CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND s u n ru n 1a NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 1b NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 00825-ME 2a 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 1n LAMLSOIIE ROCK ROnD,WESleI1RY,NY 11590 PHpJE 995.SGD.Ei97 2b 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHNITHWN-2 CUSTOMER RESIDENCE: 3a 1"PVC OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNITHWN-2 PETER CVIKEVICH 475 RAMBLER RD,SOUTHOLD, NY,11971 3b 1"PVC OR EQUIV. (2)8 AWG THHNITHWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHNITHWN-2 TEL.(516)242-0628 4 1"PVC OR EQUIV. (2)6 AWG THHNITHWN-2 (1)8 AWG THHNITHWN-2 (1)8 AWG THHNITHWN-2 APN:1000-088-00-05-00-032-000 PROJECT NUMBER: 216R-475CVIK MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 U650 OPTIMIZER CHARACTERISTICS: DESIGNER: (415)580-6920 ex3 HANWHA Q-CELLS:Q.PEAK DUO BLK SYSTEM SIZE: 6970 W SYSTEM SIZE: 10250 W MIN INPUT VOLTAGE: 8 VDC JOHN PAUL TECSON ML-G10+410: 410 W SYSTEM OPEN CIRCUIT VOLTAGE: 9 V SYSTEM OPEN CIRCUIT VOLTAGE: 13 V MAX INPUT VOLTAGE: 60 VDC OPEN CIRCUIT VOLTAGE: 45.37 V SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 380 V MAX INPUT ISC: 18.75 ADC SHEET MAX POWER VOLTAGE: 37.64 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX OUTPUT CURRENT: 15 ADC ELECTRICAL SHORT CIRCUIT CURRENT: 11.2 A SYSTEM OPERATING CURRENT: 18.34 A SYSTEM OPERATING CURRENT: 26.97 A SYSTEM SHORT CIRCUIT CURRENT: 30 A SYSTEM SHORT CIRCUIT CURRENT: 30 A REV:A 12/30/2024 PAGE PV-4.0 INVERTERI 7ELECTRICAL ��� • • • • • NOTES AND SPECIFICATIONS: - •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE SHOCK HAZARD PHOTOVOLTAIC SYSTEM 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR 480 IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM CIRCUIT CURRENT: 30 WORDS,COLORS AND SYMBOLS. NALS ON LINE AND LOAD DO NOT ADD LOADS MAY BE ENERGIZED IN D. . •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING HE OPEN POSITION LABEL LOCATION: - •� 15 , METHOD AND SHALL NOT BE HAND WRITTEN. PHOTOVOLTAIC AC COMBINER(IF OR CONTROLLE •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE), INVOLVED. LABELLOCATION: PER CODE(S):CEC 2019:705.12(B)(2)(3)(c), LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), NEC 2017:705.12(B)(2)(3)(c) INVERTER(S),OC DISCONNECT(S). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL OF APPLICABLE). PER CODE(S):NEC 2017:690.53 •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):CEC 2019:690.13(B),NEC 2017:690.13(B) 77, INVERTER2 �i� Y • • • •POWER SOURCE OUTPUT CONNECTION IDADC 480DO NOT RELOCATE THIS ICOVERCURRENT DEVICE MAXIMUM CIRCUIT 30 RATED OUTPUT LABELLOCATION: LABEL LOCATION: . OF NEW I� ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN CONTROLLER OR DC-TO-DC • INSTALLED ADC APPLICABLE). SERVICE PANEL. G3��0PK Kq��4 0 PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(B)(3),NEC LABEL LOCATION: * �P I' pl 705.12(B)(2)(3)(6),NEC 2017: 2017:705.12(B)(3) INVERTER(S),OC DISCONNECT(S). 705.12(13)(2)(3)(6) PER CODE(S):NEC 2017:690.53 C- W ■•• , ,. . . BUILDING SUPPLIED BY UTILITY AA 106286 ' GRID AND PHOTOVOLTAIC aI$'iio ��FESSIONP LABELLOCATION: SYSTEM INSTALLED WITHIN 3.OF RAPID SHUT DOWN s u n r u n SWITCH PER CODE(S):CEC 2018:690.56(C)(3),NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018: 1204.5.3,CFC 2019:1204.5.3 4 PHOTOVOLTAIC AC DISC' OLAR PV SYSTEM E R UIPPCD ® 00825-ME MAXIMUM• OPERATING • - t�)LANfV.GOE ROCK ROAD,WERTBURY,NY 11599 NOMINAL OP ER WITH RAPED 1HA pp N R ONE 695.54�.548] fAXB65.168.ZY13 LABELLOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF CUSTOMER RESIDENCE: INTERCONNECTION. PETER CVIKEVICH PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 475 RAMBLER RD,SOUTHOLD, 3„ TURN RAPID SHUTDOWN NY,11971 SWITCH TO THE"OFF' • • POSITION TO SHUT DOWN PV SYSTEM TEL.(516)242-0628 PV SYSTEM AND REDUCE DISCONNECT APN:1000-088.00-05-0D-032-000 LABEL LOCATION: SHOCK HAZARD IN THE PROJECT NUMBER: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, ARRAY. LABEL LOCATION: 216R-475CVIK AT EACH TURN,ABOVE AND BELOW PENETRATIONS, POINT OF INTERCONNECTION ON EVERY JB/PULL BOX CONTAINING OC CIRCUITS. (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) DESIGNER: (415)580-6920 ex3 PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4), JOHN PAUL TECSON NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: 605.11.1.4 LABEL LOCATION: SHEET ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIG NAG E DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S):CEC 2019:690.56(C)(1)(a),NEC 2017: REV:A 12/30/2024 69D.56(C)(1)(a) PAGE PV-5.0 DUO BLK Q, PEAK { IVIL-G10+ SERIES ocells 390-410 Wp 1132 Cells 20.9% Maximum Module Efficiency MODEL Q.P---AK DUO BLK ML-G10+/t Breaking the 20%efficiency barrier 111f,11111111111 ILLLILLL Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. ,25 A reliable investment Inclusive 25-year product warranty and 25 year linear Warranty performance warranty'. Enduring high performance Long-term yield security with Anti LeTID Technology, Anti P1D Technology'and Hot-Spot Protect. Extreme weather rating High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads 14000 Pa). rm�[_ Innovative all-weather technology Optimal yields,whatever the weather with excellent low-light and temperature behaviour. The most thorough testing programme in the industry Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new'Quality Controlled PV'of the independent certification institute TUV Rheinland. see data sheet on rear for further intormation. 'APT test conditions according to i6GTS 62804-t2015,method A(-1500 V,96h) The ideal solution for: Rooftop arrays on ° residential buildings DUO 0LK ML-G10+ SERIES ■ Mechanical Specification rr p'YJIAmm.I �� ,aa na§amml Format 74.0In x 41.1 in x 1.261n(including frame) (1879mm x 1045mm x 32mm) # Weight 48.5 lbs(22.0 kg) III =I6an�9oonvv0•a'<:5�w = Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass ,,,.,,,° , with anti-reflection technology rrpp Back Cover Transparent composite film with black grid Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells -4D Junction box 2.09-3.98In x 1.26-2.36in x 0.59-0.71in ` a (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes Cable 4mm'Solar cable;(+)a72.041n(1830mm),(-)2:72.04in(1830mm) j ,ti 06.E -)L t n'uD Tm Connector Staubll MC4;IP68 ��.==s,,,•,I i��--lass'ds.--, ■ Electrical Characteristics POWER CLASS 390 395 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS.STC'(POWER TOLERANCE+5 W/-O W) BSTC' BSTC' BSTC' BSTC' BSTC' Power at MPP' P,,,, [W] 390 426.6 395 432.1 400 437.5 405 443.0 410 448.5 Short Circuit Current' Is, [A] 11.01 12.05 11.04 12.08 11.07 12.11 11.10 12.15 11.13 12.18 E 45.49 4565 4552 4568 45.55 45.72 45.59 45.75 45.62 45.78 m Open Circuit Voltage' Voc [V) . . . .9E Current at MPP I„„, [A] 10.39 11.37 10.45 11.43 10.50 11.49 10.56 11.55 10.61 11. 61 Voltage at MPP V•D„ [V) 37.54 37.53 37.81 37.61 38.09 38.08 38.36 38.35 38.63 38.62 Efficiency' rl [% z19.9 Z20.1 Z20.4 ?20.6 >-20.9 1 Bifaciality of P,,,,and Ix 70%±10%-81faciality given for rear side Irradiation on top of STC(front side)•According to IEC 60904-1-2according to IEC 60904-3 l Measurement tolerances Pm_±3%;Isc,Vo,±5%at STC:iOOO W/m';'at BSTC:1000 W/m'+(p x 135 W/m',q)=70%±10%,25±2°C.AM 1.5 according to IEC 60904-3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.NMOT2 Power at MPP P,,,, [W] 292.6 296.3 300.1 303.8 3076 E Short Circuit Current Isc [A] 8.87 8.89 8.92 8.94 8.97 E Open Circuit Voltage Vol. IV] 42.90 42.93 42.96 42.99 43.03 2 Current at MPP IN== (Al6.16 8.21 8.26 8.31 8.36 Voltage at MPP V,,,,, [V] 35.86 36.10 36.33 36.57 36.30 'Measurement tolerances Pm.±3%;Isc:Voc±5%at STC:1000 W/m2,25±2'C,AM 1.5 according to IEC 60904-3-'800 W/m2.NMOT,spectrum AM 1.5 Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE aR 100 At least 98%of nominal power during first year.Thereafter max L, o isI __"-_ "_ __"_________ 0.5%degradation per year.At ur - least 93.5%of nominal power Y i i up to 10 years.At least 86%of 1. f I, nominal power up to 25 years. ' * z zo a H yo es l_c=s�cc:: a=:.=- =o•==�= All data within measurement q: tolerances.Full warranties in _ 'I accordance with the warranty Q f eo terms of the Ocells sales Q$ o as - ,o ,s xo :s organisation of your respective 200 a00 6O0 8O0 1p°o _ IRRADIANCE lWrm'I o YEARS country. 'standard terms of guarantee for the s Iry companies with the Typical module pedormance under low inadiance[ond2ions in - highest production capacity In 2021(February 2021) -Parison to STC rmrifffons R5'C,1000Wrm'1 N TEMPERATURE COEFFICIENTS 6 a 6/K +0.04 Temperature Coefficient of Va 13 [%/K] -0.27 t? Temperature Coefficient of Isc [° ] i 109±5.4 x Temperature Coefficient of PMPP Y [%/K] -0.34 Nominal Module Operating Temperature NMOT ['F) (43±3'C) m o ■ Properties for System Design i Maximum System Voltage Vsys IV] 1000(IEC)/1000(UL) PV module classification Class II a 20 Fire Rating based on ANSI/UL 61730 TYPE 2 Maximum Series Fuse Rating (A DC) 40 T up to+185'F a Max.Design Load,Push/Pull' [Ibs/ft'] 75(3600 Pa)/55(2660 Pa) Permitted Temperature -40°Cu to+85°C on Continuousous Du Duty (- p ) Max.Test Load,Push/Pulls (Ibs/ft2] 113(5400 Pa)/84(4000Pa) 5 a 'See Installation Manual ■Qualifications and Certificates g w UL 61730.CE-compliant. Quality Controlled PV-Tl1V Rheinland, IEC 61215:2016.IEC 61730:20,:. S U.S.Patent No.9,893.275(solar cells), ,a c us ,o,n,amn ❑ s Ocells pursues minimizing paper output in consideration of the global environment. �aI IS Note:Installation Instructions must be followed.Contact our technical ServiceOe for further information on approved installation of this prodlm Ha nwha o CELLS America Inc.400 Spectrum Center Drive.Suite 1400•Irvine,CA 92616.USA I TEL N 949 748 59 961 EMAIL hgc.inquiry$gcells.com IWEB www.gcelli.com solar=@@ • Single Phase Inverter with HD-Wave Technology • for North America I 00001Li-U U S Sr - S E I �'OOH, U SE600OH-1j"S SE7600H solar=-- solar=,- JI-11D...- e (bes OF W. optimized installation -with-HO.-Wave technol6gy. - specificblly designed to work with power,a porniiers, Record-breaki'ng efficiency' Fixed voltage inverter.for longer strings 6 shutdown o� "O�nd 201 per article 650.11 and 690.12 Integrated arc fault protection a�d�r'ap_4 � f NEC 2014 7 -grid cornplia�c A1741 SA certified;f6r CPUC Rplell Exirerhely small Hi reIiabifityAi out any-Oi�ctroydc.6apacit rs_ Built4n module-level rnon'i'tonn.g- OU I td.'oo- and indoor installation. "wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) solar=@@Single Phase Inverter with HD Wave Technology for North America SE300011H-US SE3300H-US SE50,013H-US S�6000H-US ISE7600H-US . SE1000!TH-US SE11400H-US - - - 0 - - — SE3U0UH-US SE3SflON US SE500OH-US SE6000h1-US , SE7600H-US SESOOODH US . SE114 OUTPUT - -- 60,130 ID 240V Rat-_r;A -'owe'Ouc.,,,- CO 208V SG00 IP 208V 6C0 CCn 33GU 2d'CV E` i .. CC0 M 111u . A. Owe 3;3C 0 iP 2CSV ; CO 'GCIi rti 20-3V .AC Output Voltage 1a;n.;�lOrr L7ax , r" t f Vac li 240-Z,al AC Frequent;'.!i'Nominalj 60 Viaxi rwr Continuous Output Ourrer;r 16 24 A 208V Maximum Cont ruous O_ctput Curren', Z 5 5 25 3Z 42 % M 240`! A GFO!Thr snc d uniity^Jlonit,7r`n„Islanciing Protecd-on: .-ountry Conf gurab!e'i i re hOl is INPUT 1550r \ axit um,pr �ver ?Z40+ .uSQ 59Co 2750 07756 1?5-C -rin;0.!rer Iris,Un?r::n.;rded +Viax!r^um inpui`/olta;e 430 NGrrina!X Input Voltage 330 ,v?axim:r rput Otu'rent'_t:$`•/ = 1'3 5 aaaxilr„rr'n11ut Currear r��Z:u)V _ 30 5 d 9.5 1 13.7 15.5 AdCc M 1,4.!n a U t;h0!t�11":U!t C�!„ent 45 ;r-:und-Fault'solario•n Oerac't„Dr, 6t)OK::J Sansit vita y 99.' _)9 hghr,ie Dower ur Cen <Z.5 ADDITIONAL FEATURES - S.;pporre0 Cem nt nicarn:.^!n =fa a RC385,Etn'rr r, 7;g5ee(ooncnuii: R m eve ..e Grade Jan, N;I- C17_.20 Opr onal RaU•d SIB-:tc1ow -^1=_20141 anl!2G17 R'9ht. -saGid:iitUt'.:O•Nr! :pGn A'r Gr.,DI COnneCi STANDARD COMPLIANCE - -- - - - - -- -- -- -- - - -... - --—- - --- - - - - -- -- -- - o : L"»' Ui_+7»1 SA:J;_5995, 5\ ZZ.2,Canadian AF:_!ac:GrO:ng 'b LL.:M-:7 Sater•/ - - , !E i:L 4' :;tile Rule 14(ri; Grid Ccr;nec^on standards - rn�sso;ts INSTALLATION SPECIFICATIONS 3" *+.ittvr; , ,. A,,yr_ 3/3"nt�r.imum�14-�+A`P;G aC 7utput Conduit Size 'a`JVG Range tlr .4-6 '' r' r Cn t n�itrin�-' 3 -1"mininum i`1-'Strings oc inpu n•lui.Size? gs; 3 4"our.muht/' 2 strings, i4-6 A'N•a la-a A'WG �'•NG'ange -1.3s14.6x73. 10x3%0 n':,rt Dimensions with Safely Sw!ttf;(H.,J+/xGl '<1d z 5.3 :15 7<3i0 x 171 t 1$c ;Veighr v:t.h Safety Switch 22 1 10 25', 11.4 26.2 i=? 33.S 1 117 6 iu Ra Ni1152 g <c5 <50 G_ :OO ln7 ;Natural Convection Natural CGnV2CClOri Operidmg Tentoerat.ure Range -13 to 140 25 to'60"!{-d0'F -40'C 00tionl"" RYOt=_ct0n Ratnu NEN1.4 aft linverter with 3afet'•/Switch) d sr a.;2;.2g ora.settings:.ease'0^:act se:a-C.I -oaor: '` 1-er-e-,race -,+e..a• :':�i2xxzx-+_�CCC�:`_ . l;-�'70vJ?-':e'a:'^ .. ?:on" ':C'--:f i:((WwW.i.i:i_r.�2��^::-25iC2-].:, 'a5 i2.o_•,e•a:."..a a.a-'g^0:2-3]4' .< AG Ie"SIC °/^:.i=xxxx^viC.^.0\1.-^ I, OSolarEdge Technologies.Inc.All rights reserved. 0 -° OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarE° ;Technologies,are trademarks of their respective owners.Date:, } •P l & 3:•s ° f+A.'y:l�• �° ,�ayn i � M r�� '��r �2 •� � °$" �.;�T �s�,`. .� :�;rv,C. �;� ... - r•,2�i�!*" , sW'.a`. a e;, A. . �_� P S �tiS•� .".� i x �• r'.�""r ax 4�u�is? 'F'W' 5 .d n,;'y � f 3ki R• 'i `L i - c � 1 ,r t � .� �,a- »'fir., k�u •��` ' �* .�9 wytY� _ .S w���K'Yw'� �Rt 'n'i� M' j..pKt � � �� � �jy • �� ''(�S. �''}�`,�, � ,,:�y t�Si ri a r.: �.: rp- �` %`� �'` �4G ±.d ��� ;�� x .•' t .,s '; r' �.',.y�p�ts }, A� y�r' -: y,'R,!1 TN ..ems/r� �. _, -' � I,� ..,P,l`� .�� Y y '� v�.i,. _�iP�7R!3 :S�L�aY�':�����I��%.:a•1.��1�.L I' P System designed with :", AN parts fit in as box-for easy maximum versatility for any ' Logistics arrays .including staggered Drop-In features make the i.nstaal process intuitive and fast i� Simple cles'ign allows system to be insta.11e:d by single installer U Listed to UL Standard 2T03 or on the roof .Grounding/Bonding and Fire Classification highestis designed; to provide the fastest, most intuitive install experience for residential. roofs. The direct mount system, features four basic com ponents,for easy material 'management. Features 'incredible flexibility with.a single Universal mounts thatfit module heights from 32 - 4G mrn and the •ans-of any current rail. lets systern. ? Flash Track with Patented Umbrella Technology o Single Umbrella lag screw secures flashing and flash track to roof in one complete action . Umbrella technology provides weatherproofing with a long- lasting mechanical seal Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array . Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track . Slotted riser provides leveling for easy height adjustments R� Links j . Simple design provides mounting platform between two to four modules Clamps onto top of modules securing them in place while providing row-to-row bonding Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape W module orientations Quality. Innovative . Superior SnapNrack Solar Mounting Solutions are engineered to optimize materiall use and labor resources and improve overall . • D.ESCRIPTFON: DRAWN BY: " SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins SnapWack REVISION: Solar Mounting Solutions PART NUMBER(S): 595 MARKET STREET.29TH FLOOR•SAN FRANLISCO,CA 94105 USA PHONE 1415)580.6900 A FAX(415)580-6902 242-02155 TIIEINFORAMTIONINTHISOMWINGISCON DENDI ANDPROPRIETARY ANY REPRODUCTON,OISCLOSURE.OR USE THEREOF IS PROHIOITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH U.C. 10 5 0 0 4 3 7 ® 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 D•ESCRIPTI,ON: DRAWN BY: SNAPNRA ,CK RL UNIVERSAL, MOUNT mwatkins sm mck- REVISION: Solar Mounting Solutions PART NUMBER(S): 595 MARKET STREET,-T.FLOOR�SAN FRANCISCO.CA 94105 USA PHONE(415)580-6900 FAX(4151580-6902 242-02155 MEINFORMA ONIATHISORAI NO IS CONFlDENTIAL AND PROPRIETARY.ANY REPROOUCTION.OISCLOSURE,OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLG, �-- 1.50 3.41 F 1.50 s; 2.35 1.50 1.55 .66 2.00— 1.00 1.24 SLOT sy 2.63 �— — 1.50--� ALL DIMENSIONS IN INCHES