49305-Z
of souryo`o Town of Southold * * P.O. Box 1179 io 53095 Main Rd N Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46087 Date: 04/07/2025 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 340 Summit Rd Southold, NY 11971 Sec/Block/Lot: 78.-9-27 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 04/26/2023 Pursuant to which Building Permit No. 49305 and dated: 05/24/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additions and alterations, including non-habitable open second floor storage loft, to existing single-family dwelling as applied for. The certificate is issued to: James Arvotti Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49305 02/05/2025 PLUMBERS CERTIFICATION: Brad Piecuch 01/27/2024 f)ni A t oriz d Signature �ao�svFFoi�,cOG TOWN OF SOUTHOLD BUILDING DEPARTMENT y= TOWN CLERK'S OFFICE "Dy_• o� , SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49306 Date: 5/24/2023 Permission is hereby granted to: Arvotti, James 33 Miller PI Levittown, NY 11756 To: construct additions and alterations to existing single-family dwelling as applied for. At premises located at: 340 Summit Rd, Southold SCTM #473889 Sec/Block/Lot# 78.-9-27 Pursuant to application dated 4/26/2023 and approved by the Building Inspector. To expire on 11122/2024. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $299.60 CERTIFICATE OF OCCUPANCY $50.00 Total: $349.60 Building Inspector OF SO!/r�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 � �o Jamesh _southoldtownny.gov MUM,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jim Avotti Address: 340 Summit Road city:Southold st: New York zip: 11971 Building Permit#: 49305 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Peconic Power System: Electrician: Robert Stanevich License No: ME-45056 SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt 32 Ceiling Fixtures 7 Bath Exhaust Fan 2 Service 3 ph Hot Water tankleE GFCI Recpt 3 Wall Fixtures 3 Smoke Detectors 2 Main Panel 200a A/C Condenser 1 Single Recpt Recessed Fixtures 20 CO2 Detectors Sub Panel 200a A/C Blower 1 Range Recpt 1 Ceiling Fan 3 Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 23 4'LED Exit Fixtures Sump Pump Other Equipment: 2ft baseboard heat,1 fridge, 1 micro, 1 dishwasher Notes: HOUSE Inspector Signature: Date: February 5, 2025 340 summit rd %;1vnHaffAnnex _0.Box 1179 GO BLULMGDEPARTMENT."I G.. JA N 2 7 2025 TOWN OF SOMMOLD O�M CAn�N Pate., Buds itNO. o �r- KD+ i Plulnher_ -b r-ma f -P—C u-ch {please ) T certify that the solder used in the water mpply system contains lea than 211 G©f 1%lead. ('hunbm Ste) Swm to before craze this day of " LOL r 20 NPubffr, CouW SiI&M A..�D NOjMyPubRr,- O- p9LOI ChmUnd in 0004 OE SOUTyOlo f * TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECMN [ ] FOUNDATION 1ST [ ROUGH PLBG. [ ] FO ATION 2ND [ ] INSULATION/CAULKING [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: w�hQi � DATE INSPECTOR ho��OF SO(/ly�� # TOWN OF SOUTHOLD BUILDING DEPT.- °y a►��i� 631-765-1802 INSPECTION ' [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ I)NgULATIOWCAULKING [ ] FRAMING/STRAPPING [ .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE.RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL'(FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL MAR S: 6 DATE l INSPECTOR �- so Z (3 n hO��0EUTyO6 ��d0 itv # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] --FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [.. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] :FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [)C] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: A U6 neeG� CbWL v DATE o2 INSPECTOR �j [�r1 ` �/�� ,.fin J� OF SOUIyOIo �7 305 - o 6w �L�"(�4 � AolS # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [Al ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE �'S" °2� INSPECTOR OF SO//TyOI -- - ���� } TOWN OF SOUTHOLD BUILDING DEPT. °`ycourm��' 631-765-1802 INSPECTION ( ] FOUNDATION 1ST [ ] DOUGH PL13G. [ ] FOUNDATION 2ND INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: rAtvl� V A.4L DATE y 'ZD INSPECTOR 21 2p2r' _ A AN _ � 'y Y'n15 A . OF ® , Oa CY"n M = IMMMMMUS=1 ,UMMUN Spray Foam Specialia#s ICYNENE' Radiant Drywall and Insulation Corp. VJr�wrCC'; www.RadiantlnsulSvstems.com, P O Box 899 Middle Island, NY 11953 Phone:631-92"500 Fax:631-924-4584 Envir®Drio Commercial Lic:Suffolk:36254-H Residential Lic:Nassau : H1901650000 Certificate of Insulation 1/14/2025 Torkelsen & Co. Inc. Jobsite: 800 Summer Lane 340 Summit Road Southold, NY 11971 Southold Radiant Insulation Systems has installed the following insulation items. Please see the locations and values as listed. House PACKAGE: Demilec Closed Cell Spray Foam installed in Attic Slope at 2.5" (R-18.7) RockWool Comfort Batt R-30 7.25 x 15.25 x 47 installed in Attic Slope RockWool Comfort Batt R-15 3.5 x 15.25 x 47 installed in Attic Gable Ends R-15 3.625 X 15.25 Kraft Faced Fiberglass installed in 2 x 4 Exterior Walls R-15 3.625 X 15.25 Kraft Faced Fiberglass installed in 2 x 4 Exterior Walls R-13 3.625 X 16 Unfaced Fiberglass installed in Sound Walls White Caulk 10.1 oz Tubes installed in Insulation Phase Items Fire Caulk (Red) 10.1 oz installed in Insulation Phase Items Soudal Window and Door Foam installed in Insulation Phase Items HERS Index Air Seal installed in Insulation Phase Items Wire Stays 16"- Insulation Phase Items Basement PACKAGE: R-21 5.5 x 15 Kraft Faced Fiberglass installed in Basement Ceiling Demilec Closed Cell Spray Foam installed in Basement Joist End at 1.5" (R-11.2) 1 , &' Tony Costagliola Vice President Radiant Insulation Systems >,: � -, � 1 i "'` 1 �..;�,�,�..: f � � ' i �� yy �' �� � !�.. ... rT}. — } �i � }+ ' I, ,ic,e } � 4 � �.,:.;,;!� I: � ;y, � � ! �' ' � :r i _ � 1 'ri r it I i i ��'1� '� ��� �._� �, i ' s K,f �� `�� ��f �. ���� � _� f ��� � �,. .�; J � .,,. ,� :l � .; ! .� , �.� _�, r ,� _: ' � , ,� �r f� ref. ,,,w y ,. ' �:xs '��.r � ....... ,r ',�:�� � � , ��yy ,�� P f ' � 4 . I � 1 � y' p 1 1 a ro 1; R �• �1 � y�3�� a �:�. �r� \� -�..,� ��� . . i,�, �_ �" �� �, �l A �' � 1 ��C� F�. � � •--' L:; �. -- r -. .�..,.. .. .. 3 � ~ ,.,p' ^ a �" :a 4. •. \'. _ _�... _ j m._. ... ...... �__ �f o:t i�, . �. `Y t: R FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) V ' y ------------------------------------ sy C f FOUNDATION (2ND) cio �C ROUGH FRAMING& a 1 PLUMBING t� s- INSULATION PER N. Y. 4 m STATE ENERGY CODE n G r � FINAL r4L VAIL ti> rot ADDITIONAL COMMENTS r Qiay -Z i X - U r* 5 b " N N O x x _ d b fF°iK ova TOWN OF SOUTHOLD—BUILDING DEPARTMENT a Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 `Q a ag Telephone(631)765-1802 Fax(631)765-9502 bgps://www.southoldtow2ny.g2v Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ID) t G e i! m I� PERMIT NO. Building Inspector: I APR 2 6 2023 = 1 BUILOINU DEPT. � Applications and forms must be filled outin their entirety, Incomplete TOUUN OFSOUTh9(1Lp applications will not be accepted ,Where;the AppUcant is not the owner,an Owner's Authonzation form(Page 2)shal_I be completed J q ^ Date: 4/24/2023 R(S)&PROPERTY OW IiE Name: Jim Arvotti SCTM#1000-78._9727 Project Address:340 Summit Road, Southold,.NY Phone#.516 902 0359 Email:jarvotti@aol.com Mailing Address:33 Miller Place, Levittown,, NY 11756 CONTACTPERSON „ Name: Karen_.Szczotka,_Agent „ Mailing Address:205 Bay Ave., Greenport, NY 11944 Phone#: 631 477 9752 Email karen@ribrownarchitect.com DESIGN I PROFESSONAL,,INFORMATI,ON ,. . z Name:Robert I. Brown AIA Mailing Address:205 Bay Ave., Greenport,.NY 11944 Phone#: 631 477 9752 Email:rob(@-ribrownarchitect.com 4,4 CONTRACTOR INFORMATION: Name: TBD Mailing Address: Phone#: Ema 1.il: DESCRIPTION OF'PROPOSED CON,$TRUCTION v`'r ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $100,000 Will the lot be re-graded? ❑Yes R No Will excess fill be removed from premises? ❑Yes 8 No 1 .0 n ,r:PROPERTY INFORMATION' Existing use of property: Intended use of property, ` SIP GLC- fAMlly„ _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to r1 _ yO this property? ❑Yes %No IF YES, PROVIDE A COPY. 'Check Box After Reading The owner/contractor/design professional Is re5ponslble for all drainage and storm water issues as provided by " �I I ._ e4, p sr ._ a ter''236 of the.Town Code. APPLICATION IS`HEREWMADE to the'Building,Depaitinent for.the Issuance of;"Buildi'ng Permitpursu'ant'to,.theBuildtng'2one Ordinance of;the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances=or Regulations,for the construction ofibuildings,.. additions,alferatlons or for removal or demolltiori`as herelg`described The appllcant,agrees to comply with all appl cabie�lawi,ordinances,'building,code,, - b, ..e housing code'Fand regulations an-'A&admit'authorizedrtnspectors on premisgs°antl Inl liulldlrig(s);fgr necessary Inspections'False statements made herein are- punlshable asa class Amisdemeanor pursuant toSectlon 210 45 of tie New York StatePenal Laing ._te.+. ��. i-N .'. ..Mu.,r ` .ti-. 4i la Application Submitted By(print name): RYA S ibof?- MAuthorized Agent ❑Owner Signature of Applicant: Date: CONNIE-D:BUNCH__._. Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 sS: Qualified in Suffolk County COUNTY OF Commission Expires April 14,2� ) IZ-yAP 5►Aa2 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor en orporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Laay of , 20-D3— Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, SArAes Atv -R► residing at '✓yo SuMMtT ROAD o do hereby authorize fLvBERT L Bid AR.armT At. to apply on 4-A64Z my b h if--tn a own of hold Building Department for approval as described herein. --- -LS - ZDti3 �- ,0� // s Ldy ature Date �lA4I1✓®7rT7' Print Owner's Name 2 .3 J BUILDING DEPARTMENT-,thactricc- e TOWN OF SOUTHOLD �-A Town Hall Annex- 54375 Main Ro ad ad P Southold, New York 11 4095 Telephone (631) 765-1802 - F (631) 765-9502 iamesh(cD-southoldtownny.gov- sea nd(ED-south oldtown ny._qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 1/29/24 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmaii.com Elec. Phone No: 516-819-7191 0 1 request an email copy of Certificate of Compliance Elec. Address.: PO BOX 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Jim Avotti Address: 340 Summit Rd, Southold Cross Street: Cedar Drive Phone No.: 516-902-0359 Bldg.Permit#: 49305 email:Javotti@aol.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Complete renovation of existing single family dwelling Square Footage: 1800 Circle All That Apply:Is job ready for inspection?: 21 YES [:] NO rV-]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YESFV-1 NO issued On Temp Information: (All information required) Service SizeF-11 Ph❑3 Ph Size: A # Meters Old Meter# MNew Service[]Fire Reconnect E]Flood Reconnect Oservice Reconnect E]Underground nOverhead #Underground Laterals E]1 F-12 0 H Frame El Pole Work done on Service? Y F]N Additional Information: E E 0 V E n U AYMENT DUE WITH APPLICATION JAN 2 6 2024 /QD Building 1,131eparlm-ent iovoil 011 Southold r? ®SUFFO(,� BUILDING DEPARTMENT-ElectricA p r 9S® �4�� TOWN OF SOUTHOLD ...•.. CM Town Hall Annex - 54375 Main Roa =•PQ't B.oX 1`1 '9 Southold, New'York 1197- =6959 Telephone (631) 765-1802 - F (631) 765-9502 r ® } jameshgsoutholdtownny.gov-- sea nd@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/29/24 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich -License No.: ME-45056 Elec. email: Peconicpowersys@gmail.c6m Elec. Phone No: 516-819-7191 ❑I request an email copy of Certificate of Compliance Elec. 'Address.: PO BOX 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Jim Avotti Address: 340 Summit Rd, Southold Cross Street: Cedar Drive Phone No.: 516-902-0359 Bldg.Permit#: 49305 email:Javotti@aol.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Complete renovation of existing single family dwelling Square Footage: $oo Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In ` ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph 73 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? OY N Additional Information: EC� � IWE AYMENT DUE WITH APPLICATION I �;Lqlxy J A N 2 6 2024 E!t sjo:ii'eS g C,JGPCS:l9 a.++li t PERMIT N Address: Switches Outlets"' - lW 8 �'h I l li' 6W GFI's lit Surface#VV' Sconces a, ` H H's UC Lts -ans - 1 Fridge I HW xhaust �� Oven W/D mokes DW 1 Mini .arbon Micro Generator .ombo 1 � Cooktop- Transfer ,C A C orw�+— Hood Service Amps Have Usec pecial- omments Scott A. Russell S�C'�0�][�.I��l WA\�['JE�[Z SUPERVISOR ��l[A\,NA G�]E��l[]EI�'7C' SOUTHOLD TOWN HALL-P.O.Box 1179 O' 53095 Main Road-SOUTHOLD,NEW YORK 11971 �i �. pT Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ! ( ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) — I !i APPLICANT: (Property Owner, Design Professional Agent, ntractor, Other) ?f` NAME: S Date: ' �i mint, IS] tile) Contact Information: '. I': &Mail 6 l'elephnne Numherl Ali Property Address / Location of Construction Site: S.C.T.M. #: 1000 I District � 1 li Section Block Lot S!i '♦i O BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT !I ii.- - -T - - _... _ .._ - - - - - - - - - - - - - - - - - - - - - - - - - - Area of Disturbance is less than I Acre. No S.P.D.E.S. Permit is Required ! i Project does Not Discharge to Waters of the State. No S.P.D.E.S. Permit is Required ! t o ' a ii! ❑ - Area of Disturbance is Greater than l Acre& Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit !l }; DIRECTLY From N Y S DEC Prior to Issuance of a Building Permit, i 1f� Area of Disturbance is Greater than I Acre & Storm-water Runoff Flaws Through Srn.ith( id I ii=. To4vn's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN �! a S.P.D.E.S. Permit through the Southold Town Engineerinq'Department if Prior to Issuance of a Building Permit. C„ (; Date: }i Re,-ie\,\'ed By: :,i i' FY)RM CMfP-TflCfhr�hP, �nl� ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREENPORT,NY 11944 631-477-9752 FAX 631-477-0973 info ribrownarchitect.com Transmittal Date: 4/24/23 To: Town of Southold Building Dept APR 2 6 2023 Re: Arvotti Residence dUIL INN DEFT 340 Summit Road TOMN OF SOUTHOLD Southold,NY Renovations - Enclosed please find application for the above referenced. Thank you, Karen Szczotka Agent for Robert I. Brown Architect, PC karen@ribrownarchitect.com Generated by REScheck-Web Software 1Z I Compliance Certificate Project Arvotti ADDITIONS AND RENOVATIONS Energy Code: 2018 IECC Location: Southold, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 685 ft2 Glazing Area 14% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 340 Summit Road Jim Arvotti Robert I. Brown Architect P.C. Southold, NY 11971 205 Bay Avenue Greenport, NY 11944 1-631-477-9752 info@ribrownarchitect.com Compliiance� Passes using UA trade-off Compliance: 0.6%Better Than Code Maximum UA: 160 Your UA: 159 Maximum SHGC: 0.40 Your SHGC: 0.35 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Ceiling: Cathedral Ceiling 685 50.0 0.0 0.021 0.026 14 18 Wall:Wood Frame, 16"o.c. 1,120 16.0 0.0 0.066 0.060 64 58 Door north: Glass Door(over 50%glazing) 20 0.450 0.320 9 6 SHGC: 0.45 Door west: Glass Door(over 50%glazing) 20 0.450 0.320 9 6 SHGC: 0.45 Window Kitchen north: Wood Frame g 0.300 0.320 3 3 SHGC: 0.31 Window Kitchen west: Wood Frame g 0.300 0.320 3 3 SHGC: 0.31 Window LivingRoom west 1: Wood Frame 13 0.300 0.320 4 4 SHGC: 0.31 Window LivingRoom west 2: Wood Frame 13 0.300 0.320 4 4 SHGC: 0.31 Window LivingRoom south 1:Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Window LivingRoom south 2:Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 1 of10 Prop.Gross Area Cavity Cont. Req. Prop. Perimeter Window Living Room south 3 above:Wood Frame 6 0.270 0.320 2 2 SHGC: 0.34 Window Bedl south: Wood Frame 15 0.300 0.320 5 5 SHGC: 0.31 Window Bedl east 1: Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Window Bedl east 2:Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Window Bath 1: Wood Frame 3 0.270 0.320 1 1 SHGC: 0.34 Window Bath 2:Wood Frame 3 0.270 0.320 1 1 SHGC: 0.34 Window Bed2 east 1: Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Window Bed2 east 2: Wood Frame 5 0.270 0.320 1 2 SHGC: 0.34 Window Bed2 north: Wood Frame 15 0.300 0.320 5 5 SHGC: 0.31 Floor:All-Wood joist/Truss 685 22.0 0.0 0.042 0.047 29 32 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The propose building has been designed to meet the 2018 IECC requirements in RESc k ersion : R�Scheck-Web an to comply with them requirements listed in the REScheck Inspection Checklist. Name-Title i i re D to OF[Vc`i�� Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 2 of10 . J NJ/ REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. :Section_ ,plans Verified• .Field-Verified " Pre-Inspection%Plan Review''' Complies Comments%Assumptions &Re ID; Value Value.,, p, 103.1, ;Construction drawings and ❑Complies 103.2 documentation demonstrate s= ❑Does Not [PR111 'energy code compliance for the s fi ' ❑Not Observable building envelope.Thermal .envelope represented on ❑Not Applicable construction documents. 103.1, ;Construction drawings and ❑Complies 103.2, ;documentation demonstrate E, '� ❑Does Not 403.7 ;energy code compliance for [PR3]1 ;lighting and mechanical systems ;; ❑Not Observable Systems serving multiple ❑Not Applicable ; ;dwelling units must demonstrate compliance with the IECC .Commercial Provisions. 302.1, - ;Heating and cooling equipment is: Heating: Heating: ;❑Complies 403.7 ;sized per ACCA Manual S based Btu/hr Btu/hr :❑Does Not [P,R2jz'''. ion loads calculated per ACCA Manual or other methods j Cooling: Cooling: ;❑Not Observable Btu/hr Btu/hr ❑Not Applicable approved by the code official. pp Additional Comments/Assumptions: 1 High Impact(Tier 1) :2 IMedium Impact(Tier 2) 3'1 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: IPage 3 of10 Section # Foundation Inspection Complies? Comments/Assumptions &'Req.ID 303.2,1 ` �A protective covering is installed to ;❑Complies ['FO1112 •,,,;protect exposed exterior insulation :❑Does Not Viand extends a minimum of 6 in. below :[:]Not Observable grade. :❑Not Applicable 403.9 Snow-and ice-melting system controls i❑Complies [FO12]2i installed. i❑Does Not emu', y ;[:]Not Observable ❑Not Applicable j Additional Comments/Assumptions: 1 I 1 High Impact(Tier 1) "2_1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 4 of10 ,'Section., Plans Verif Feel Verified w # Framing/Rough In inspection Va[u`e�#ied� ,. Value t �' Complies .Comments/dsJt sumptions 402.1.1, ;Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). :❑Does Not ;table for values. 402.5 3 ; :[:]Not Observable [FR2]1 ;❑Not Applicable � s 7 a r ss «� 303.1.3 ;U-factors of fenestration products l � fir:+ ❑Complies [FR4]1 .are determined in accordance * G d ,> ❑Does Not with the NFRC test procedure or ❑Not Observable ;taken from the default table. s, ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies ;�g ��� [FR23]1 ;installed per manufacturer's ,` k �, r❑Does Not instructions. � `❑Not Observable a, `❑Not Applicable '. Complies 402.4.3 ;Fenestration that is not site built tk p [FR20] is listed and labeled as meeting " � ❑Does Not 1 t F 4'§ arc h , AAMA/W DMA/CSA 101/I.S.2/A440 a l r a Not Observable ; ;or has infiltration rates per NFRC � 6„ ❑ 400 that do not exceed code P, a t ❑Not Applicable limits. ' *� s €" 402 4 5 IC-rated recessed lighting fixtures z,3 � w �w, * ", ❑Complies [FR16]? ;•sealed at housing/interior finish �� ;. []Does Not and labeled to indicate s2.0 cfm � []Not Observable (leakage at75 Pa. []Not Applicable 403.3.i :Supply and return ducts in attics k F � r ❑Complies ; [FR12] insulated >= R-8 where duct is .. ti' ,�� � ,'❑Does Not >= 3 inches in diameter and > � =°❑Not Observable , R-6 where< 3 inches:Supply and _3 x return ducts in other portions of ~'❑Not Applicable ;the building insulated >= R-6 for ;diameter>= 3 inches and R-4.2 k ;for<3 inches in diameter. � g 403.3.2 Ducts, air handlers and filter ❑Complies [FR13]1 :boxes are sealed with Tx * wr° A, ❑Does Not ;joints/seams compliant with International Mechanical Code or ❑Not Observable , International Residential Code,as w ',�, s� � � ❑Not Applicable r applicable. �x� ' ,� a" .; 40343.51. ',Building cavities are not used as `", `aa�, ❑Complies [FR15]3 ducts or plenums. ' �` d *" ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- ; R- ;❑Complies ; [FR17a?°„ above 105 QF or chilled fluids ;❑Does Not s , below 55 QF are insulated to >_R- ; 3 ,❑Not Observable , ❑Not Applicable 403.4.1 ;Protection of insulation on HVACu ��� , �` � z �,'❑Complies [FR24]1 piping k �' y _, , `#'.<❑Does Not Qj a t ❑Not Observable ❑Not Applicable ,403 5 3;',: Hot water pipes are insulated to R- R- ;❑Complies [FR18]2 zR-3. ;❑Does Not QNot Observable ❑Not Applicable 403 6' �� ';Automatic or gravity dampers are ' ' k " � E �' ° ;❑Complies y e; [FR19]2 i installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2,,..J Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 6 of10 Section Plans Verified Fleldl,Verified ,Ansulation Inspection,` ,Complies? `• ' Comments/Asssumptions & Req.I,D. Value ;Value 30311 'All installed insulation is labeled �,'� t '"� � rt,, ❑Complies ; [IN13]2 for the installed R-values rE , * n ❑Does Not ;provided. -]Not Observable []Not Applicable 402.1.1, !Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.6 ;❑ Wood ;❑ Wood ;❑Does Not ;table for values. [IN1]1 ❑ Steel ;❑ Steel ❑Not Observable ; !❑Not Applicable ; 303.2, Floor insulation installed per ❑Complies 402.2.8 ;manufacturer's instructions and , ❑Does Not [IN2]1 in substantial contact with the W , ❑Not Observable ; underside of the subfloor, or floor ' framing cavity insulation is in ❑Not Applicable ;contact with the top side of �, ��:;� �Q :• ;sheathing,or continuous d r ; linsulation is installed on the underside of floor framing and :extends from the bottom to the ¢' ,top of all perimeter floor framing ` members. ' ;y 402.1.1, :Wall insulation R-value. If this is a; R- R ;❑Complies :See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the :❑ Wood ❑ Wood ;❑Does Not ;table for values, 402.2.E wall insulation on the wall ;❑ Mass :❑ Mass :[]Not Observable [IN3]1 ;exterior,the exterior insulation V I requirement applies(FR10). j❑ Steel ❑ Steel ;❑Not Applicable ; ; 303.2 ;Wall insulation is installed per ❑Complies ❑Does Not [IN4]1 :manufacturer's instructions. r ❑Not Observable ❑Not Applicable n Additional Comments/Assumptions: 1 High Impact(Tier 1) 1 2,-J Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 7 of10 ,Section Plans Verified: Field Verified # . Final Inspection Provisions Complies? Comments/Assumptions V & Req.ID Value alue ` 402.1.1, ;Ceiling insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, ❑ Wood ;❑ Wood ;❑Does Not table for values. 402.2.2,' ❑ Steel ;❑ Steel 402.2.E ;❑Not Observable [Fill' ; 1❑Not Applicable 303.1.1.1,:Ceiling insulation installed per ❑Complies ; 303.2 ;manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every ;300ft . ❑Not Observable ❑Not Applicable 402 2 3 ; ;Vented attics with air permeable x ❑Complies [FI22]2 j insulation include baffle adjacent , �] "� ° j w ❑Does Not '�to soffit and eave vents that ;extends over insulation. Not Observable ❑Not Applicable .T. 402.2.4 ;Attic access hatch and door R- ; R- ;❑Complies (F1311 :insulation ?R-value of the ;❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies [F117]1 ;ach in Climate Zones 1-2, and ;❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ![:]Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not :either: Rough-in test:Total ;leakage measured with a J❑Not Observable pressure differential of 0.1 inch ;❑Not Applicable :w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total ;leakage measured with a ;pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 ;Duct tightness test result of<=4 ; cfm/100 cfm/100 ;❑Complies ; [F[4]1 cfm/100 ft2 across the system or ft2 ft2 ;❑Does Not <=3 cfm/100 ft2 without air ;handler @ 25 Pa. For rough in !❑Not Observable tests,verification may need to I ;❑Not Applicable :occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated ❑Complies [F124]1 :by manufacturer at<=2%of jr; n ;' ❑Does Not jdesign air flow. :,;-, ❑Not Observable ❑Not Applicable 403 1 1 Programmable thermostats ❑Complies [F19]2 installed for control of primary -]Does Not heating and cooling systems and initially set by manufacturer to fin` ❑Not Observable ; code specifications. ❑Not Applicable 403 1.2• 1 Heat pump thermostat installed z` � �� " p°'� ❑Complies [FI10]2' Ion heat pumps. ;;-s fl,�' , ❑Does Not ❑Not Observable ❑Not Applicable 403 5 1 ��,. Circulating service hot water ; � ,g,, ❑Complies ; [FI11]2systems have automatic ors. ❑Does Not accessible manual controls. []Not Observable ❑Not Applicable 1 IHigh Impact(Tier 1) "2, 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 8 of10 Section ki �PlasVer�fied F�eltl�fer�f�ed Final Inspectaort Pr"ovisions Comphes� fiomments/Assumptions 1 s ag9 ye. VB�Ue� k` `'� Vc�1�Q@ a '' tsa p 6i Ra ,Iq - � - .�r.ex iv,m .. 403 6 1 a`AII mechanical ventilation system y '� � 1 �y � ❑Complies�e [FI25]� jfans not part of tested and listed =v �� ❑Does Not HVAC equipment meet efficacy y � ;� �v_ ;, y - Not Observable ` �.jand air flow limits per Table ��� `� s � ' ��� ❑ R403.6.1. 5°w �� � * * []Not Applicable 403 2 ,Hot water boilers supplying heat '" `'a� ❑Complies A En [F126]2 -'through one-or two-pipe heating ❑Does Not systems have outdoor setback "je,, 'control to lower boiler water "��^ *"� , , t ��[]Not Observable jtemperature based on outdoor []Not Applicable �-,temperature. 403 5 AA Heated water circulation systemsti � � � ❑Complies ; Rc [F128]2 have a circulation pump.The af� � ❑Does Not system return pipe is a dedicated t � d return pipe or a cold water supply ❑Not Observable „� n pipe. Gravity and thermos- x ❑Not Applicable °5,syphon circulation systems are x � � not present. Controls for clrculatln hot Water system 9 pumps start the pump with signal 'for hot water demand within the ' s I occupancy.Controls ° •� automatically turn off the pump � � b ;when water is in circulation loop � a "j is at set-point temperature and no demand for hot water existsp,`x � °;„".; b;,'p 403 5 1t'2"'Electric heat trace systems ❑Complies ; ,IF comply comply with IEEE 515.1 or UL Mv,, � `�❑Does Not 'j 515. Controls automatically ' ❑Not Observable adjust the energy input to they a ,9a°`a.' t ❑Not Applicable .j heat tracing to maintain theN 12r,q ;desired water temperature in theme `,„ ¢r� 71 403 5.2 . `!Demand recirculation water ;, ' $ ,� q ❑Complies [F130]�. systems have controls that d xvr ❑Does Not °manage operation of the pump ❑Not Observable j and limit the temperature of the water enteringthe cold water " ❑Not Applicable t x '. 'piping to <= 1049F. `, e403 5 4 j Drain water heat recovery units gawk, ❑Complies [E131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side @hv❑Not Observable pressure loss of drain water heat i recovery units < 3 psi for �nr %,i �a []Not Applicable T individual units connected to one `s or two showers. Potable water- �'<s side pressure loss of drain water j heat recovery units < 2 psi for } (; Individual units connected t0 three or more showers. b � 404.1 ;90%or more of permanent � ' 4r ❑Complies ; [F16]1 fixtures have high efficacy lamps ❑Does Not ❑Not Observable i r ` ❑Not Applicable 4.04.1.1 , ;Fuel gas lighting systems havep• ❑Coin lies [�Q3] `-,,.,Ino continuous pilot light. A �, .'�>❑Does Not E ❑Not Observable ❑Not Applicable 40,1 3 ~;Compliance certificate posted. ;' -" ; ��, �$� ❑Complies )mff ❑Does Not .a ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2f, Medium Impact(Ti Low Impact(Tier 3) Project Title: Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 9 of10 Section y� "PiI"ans Verified . Field Verifieilr # : Final Inspection Provisions Compl�es� ' Comments%Assumptions &Re 1D - Value �V-alue q. ° 3033 ;Manufacturer manuals for ❑Complies 8 '3 ❑Does Not [fi118]3Imechanical and water heating �` z s�� ' , �� � systems have been provided. J ❑Not Observable ; El Not Applicable Additional Comments/Assumptions: 1 1 I 1 High Impact(Tier 1) 2' Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title:Arvotti ADDITIONS AND RENOVATIONS Report date: 04/25/23 Data filename: Page 10 of10 2018 9ECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 16.00 Below-Grade Wall 0.00 Floor 22.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.30 0.31 Door 0.45 0.45 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Date: Comments S.C.T.M. NO. DISTRICT: 1000 SECTION: 78 BLOCK: 9 LOT(S):27 W L.P. CD I DWELLING Ln W/WELL WATER � I I I W 50' WIDE EASEMENT FOR INGRESS/EGRESS AND UTF P&S- S.C.T.M.#1000-78-9-34.3 1500.00 S.F. or 0.03 ACRES \� LAND N/F OF w I 3 KIM A. GIBBS SUMMIT (50') AD Mr S 64'S4'30" E o 75.00 �o\ o .13 DWELLING t o o I ir) W/PUBLIC WATER � N - _ _ _ N N 150' — LIL#7 Z N 64'54',3U� W 75.D0' TIMB S IRqN PIN GUYo 14.34' IRON PIN � 64"5 '30" E EL 34.1 96.86' E 33.2 EL 34.0 s ro WELL (^P`F n 3 20.2' 8.9' �n p . x / 110 EL 31.4 F CONC, DRIVEWAY rot GARAGE STY M c0 GF 32.4 Q� 1 0 � I � EL 31.9 EL 32.2 Qj 27.1' Y 24.2' 21/ .5' DWELLING DWELLING 1 STY. FIR1 z W/WELL WATER 35 DWELLING W/WELL WATER & SEPTICCo I 1340 OVER 150' w FFL 32.9 w _ LOT 29 1000' GAL, 21 BILCO W 24.2' I I 27.2' 0 16 5' EL 30.2 EL 30.3 07 L.P. 100, to C 8'0x12'DEEP O to 01 LOT 30 'n O z N EL 28 EL 28.0 co IRON PIN EL 28.2 REBAR co / LOT 29A N 65"09'20" W 97.24' \ LOT30A - - - - - DWELLING W/PUBLIC WATER I VACANT W/GARAGE DWELLING I DWELLING \ I W/PUBLIC WATER / I W/PUBLIC WATER I WELL 150' I I I r — — — — — — — — — — — I I I I I I I L.P. I DWELLING W/WELL WATER WELL OVER 150' I DWELLING W/WELL WATER & SEPTIC OVER 150' I I THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS ADD SEPTIC & WATER 09-20-22 AND OR DATA OBTAINED FROM OTHERS. AREA: 9,557.3 S.F. OR 0.22 ACRES ELEVATION DATUM: -NAVD88 -------- UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER'IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE 5TRUC-TURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: LOT 30 OF NC4/ CERTIFIED TO: JAMES ARVOTTI; MAP OF: BAYSIDE TERRACE �P M. �o�YO� RENA ERMIRIO; FILED: MARCH 1 1, 1953 AS #2034 �� c SITUATED AT: SOUTHOLD TOWN OF: SOUTHOLD Ile- KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK �'p 050882 JF� Professional Land Surveying and Design N S P.O. Box 153 Aquebogue, New York 11931 FILE PHONE (631)298-1588 FAX (631) 298-1588 # 27-121 SCALE: 1"=30' DATE: SEPT 5, 201 8 N.Y.S. LISC. NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Woychuk ISSUES/REVISIONS RESIDENTIAL GENERAL NOTES MI5C. GENERAL NOTE5 CLIMATIC AND GEOGRAPHIC CRITERIA FROM TABLE N 1 102. 1 .2 (R402. 1 .2) INSULATION AND.FENESTRATION REQUIREMENTS BY COMPONENT 1.THI5 PROJECT 15 THE INTERJOR AND EXTERIOR RENOVATION OF A ONE 5TORYSINGLE FAMILY GROUND SNOW LOAD 20 P5F (PER FIG. I G08.2 BCNY5 2020 RESIDENCE,ZONED AS R-40(UNDERSIZED). WIND SPEED(ULTIMATE DESIGN) 130 MPH (PER FIG. I GO9.3(1)BCNY5 2020 2.THE Ec15TING HEIGHT OF THE STRUCTURE AS DEFINED BY THE BUILDING CODE of NEW YORK STATE SEISMIC DE51GN CATAGOKY B (PER SECT. I G 13 13CNYS 2020 GLAZED BASEMENT SLAB CRAWL 2020 15 I C-101 THE HEIGHT OF THE PROPOSED RENOVATION 15 20'1 WINTER DE51GN TEMP I I°F (PER TABLE N 1 10 1.2) CLIMATE FENESTRATION SKYLIGHT CEILING WOOD FRAME MA55 WALL FLOOR 3.THE TYPE OF CONSTRUCTION 15 TYPE V(13). FLOOD ZONE N/A (PER FEMA MAP) ZONE U-FACTOR U-FACTOR FENESTRATIN R.-VALUE WALL R.-VALUE R-VALUE R-VALUE WALL R-VALUE SPACE WALL 4.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE of NEW YORK FROST LINE DEPTH 30 SHGC R-VALUE DEPTH R.-VALUE WEATHERING PROBABILITY SEVERE (PER BCNY5 2020 STATE,2020 EXISTING BUILDING CODE of NEW YORK STATE,AND THE AF t PA\HOOD FRAME DESIGN LOAD CALCULATIONS (UNIFORM LIVE LOADS) CONSTRUCTION MANUAL 2015 HIGH WIND EDITION. 4 0.32 0.55 0.40 49 20 OR 13+5 8/ 13 19 10/ 13 10, 2FT 10/ 13 5.DESIGN LOAD CALCULATION ARE BASED ON: PER TABLE I G07.I BCNYS 2020 LIVE LOAD:AS PER TABLE R301.4,BUILDING CODE of NEW YORK STATE 2020. ROOMS OTHER THAN SLEEPING 40 P5I P R VED AS NOTED RETAINSTORi�9 WATER RUNOFFDEAD LOAD:CALCULATED AS PER R301.3 AS PER BCNY5 2020. ATTICS ROOMS 30 P51 SNOW LOAD:20 PSI GROUND SNOW LOAD(AS PER FIG.R301.2(5)BCNY5 202D. ATTICS WITH LIMITED STORAGE 10 PSI ATTICS WITHOUT STORAGE I O P51 DATE: gy;B.P.# PURSUANT TO CHAPTER 236 WIND EXPOSURE CATEGORY'I FOR 130 MPH 3 SECOND GUST. STAIRS 40 P51 FEE: OF THE TOWN CODE. � LOCATION LIVE DEAD DELECT LIMIT I ST.FL. 40 LB. 12 U3G0 NOTIFY BUILDING DEPARTMENT AT 2ND.FL.(SLEEP AREA) 30 LB. 12 V3G0 NAILING SCHEDULE 765-1802 8 AM TO 4 PM FOR THE ATTIC(NON STORAGE) 20 LB. 10 L/3GO (PER AF t PA AMERICAN WOOD COUNCIL WFCM FOR FOLLOWING INSPECTIONS: ROOF 20 LB. 15 UI ONE AND TWO FAMILY DWELLINGS 2015 513C HIGH WIND EDITION) JOINT DESCRIPTION NUMBER OF COMMON NAILS NAILSPACING 1. FOUNDATION - TWO REQUIRED P(-(�(�/��1� - G.THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE CONSTRUCTION MEPN5,METHODS, TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN ROOF FRAMING W FOR POURED CONCRETE PLUMBING,�tL PLI.PdBING V'JAS'1'E: CONNECTION WITH THE WORK. RAFTER TO TOP PLATE CrOE-NAILED) 3 PER RAFTER 2. ROUGH - FRAMING & PLUMBING &WATER LINES NEED THERE ARE NO WARRANTIES,NOR ANY MEPCHANT1131LITY OF FITNESS FOR A SPECIFIC USE EXPRESSED CEILING JOINT TO TOP PLATE(rOE-NAILED) 3 PER J015T 3. INSULATION Tta `IIvG,BEFORE COVERIPJ�,:, 4. FINAL - C OR IMPLIED IN THE USE OF THESE PLANS. CEILING J015T TO PARALLEL RAFTER(FACE-NAILED) 3 EACH LAP b 7.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE STARTING CONSTRUCTION.DO NOT SCALE CEILING JOINT LAPS OVER PARTITION((FACE-NAILED) 3 EACH LAP L p CONSTRUCTION MUST DRAWINGS.FOLLOW DIMENSIONS ONLY. RIDGE STRAP(EACH END) 2 PER TIE 8.CONTRACTOR(5)SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OR BLOCKING TO RAFTER(TOE-NAILED) 2-8d EACH END BE COMPLETE FOR C.O. DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,CONDITIONS,OR EXCEPTIONS RIM BOARD TO RAFTER(END-NAILED) 2-1 Cd EACH END ALL CONSTRUCTION SHALL MEET THE WALL FRAMING REQUIREMENTS OF THE CODES OF NEW NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,AND TOOLS NECESSARY TO N RACTOR OMPLETEHACTOR TOP PLATE TO TOP PLATE(FACE-NAILED) 2-1 Cd PER FOOT YORK STATE. NOT RESPONSIBLE FOR PLUMBER CERTIFIOATION TOP PLATES AT INTERSECTIONS(FACE-NAILED) 4-1 Cd J015T EA.SID 9.ALL MATERIAL SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURES REQUIREMENTS E STUD TO STUD(FACE-NAILED) 2-1 Cd 24"O.C. DWELLING DESIGN OR CONSTRUCTION ERRORS. ON LEAD CONTENT BEFORE AND SPECIFICATIONS. HEADER TO HEADER(FACE-NAILED) ICd I G'O.C.ALONG EDGES W/WELL WATER CERTIFICATE OF OCCUPANCY 10.CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS,APPROVALS AND CERTIFICATE OF TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-1 Cd,3-1 Cd,4-1 Gd PER 2x4,2xG,2x8 RESPECTIVELY LO OCCUPANCY. BOTTOM PLATE TO FLOOR J015T,BAND JOIST, SOLDER USED IN WATER DEMOLITION END JOIST OR BLOCKING(FACE-NAILED) 2-1 Gd PER FOOT 1. CONTRACTOR SHALL DEMOLISH WALLS,FLOOR, AND EXISTING ROOF AS INDICATED ON DRAWINGS FLOOR FRAMING COMPLY WITH ALL CODES OF SUPPLY SYSTEM CA�!^.LOT AND AS NECESSARY,AND REMOVE ALL DEBRIS. JOIST TO SILL,TOP PLATE TO GIRDER(TOE-NAILED) 4-8d PER JOIST 2. CONTRACTOR SHALL DO ALL PATCHING REQUIRED DUE TO REMOVAL OF EXISTING WORK AND OF BRIDGING TO J015T(TOE-NAILED) 2-8d EACH END W NEW YORK STATE & TOWN CODES EXCEED 2110 Of I% LEAD. INSTALLATION OF NEW WORK,AS NECESSARY. BLOCKING TO JOIST(TOE-NAIL fD) 2-8d EACH END - - - _ - - 3. ALL NEW WORK SHALL MATCH AND MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UNLESS BLOCKING TO SILL OR TOP PLATE(FACE-NAILED) 3-1 Gd EACH BLOCK + AS REQUIRED AND CONDITIONS OTHERWISE NOTED. LEDGE STRIP TO BEAM(FACE-NAILED) 3-ICd EACH JOIST 4. EXISTING STRUCTURE AND INTERIORS TO REMAIN SHALL BE PROTECTED AS NECESSARY DURING JOINT ON LEDGE TO BEAM(TOE-NAILED) 3-8d PER JOIST �'11 DEMOLITION AND CONSTRUCTION. BAND J015T TO J015T(END-NAILED) 3-1 Cd PER J015T 50' WIDE EASEMENT 5. CONTRACTOR SHALL PROTECT EXISTING SERVICES TO REMAIN AND SHALL NOTIFY ALL UTILITIES AND BAND J015T TO SILL OR TOP PLATE(TOE-NAILED) 2-1 Gd PER FOOT ELECTRICAL TELEPHONE SERVICES AND MAKE ARRANGEMENTS FOR HOOK-UP,REMOVAL,OR CAPPING OF EQUIPMENT ROOF SHEATHING FOR INGRESS/EGRESS St . =1' ! I G EOARD AS NECESSARY. STRUCURAL PANELS 8d (TABLE 3.8) (� I A1�6- UTfElFIE S�7' ,+V TfiUSTEES ASP=CTiU�`J REQUIRED DIAGONAL BOARD SHEATHING � S.C.T.M.#1000-78-9-34.3 FOUNDATIONS I"xG"OR 11 2-8d PER SUPPORT 1500.00 S.F. or 0.03 ACRES N. . ,DIC, 1.A55UMED SOIL BEARING CAPACITY, 1,500 Ib./5q.Ft. I'x 1 O"OR WIDER 3-8d PER SUPPORT LAND N/F OF 3.ALL CRETE TO BE NEW EW FOOTNGSLTO RESTONRUNDISTURBOED SOIL. CEILING DAY TEST. CEILING SHEATHING Lu \ KIM A. GIBBS GYPSUM WALLBOARD 5d coolers 7-EDGE/ 10'FIELD - All exterior lighting GENERALCONSTRUCTLON WALL5HEATHING SUMMIT (50') P10AW o S 64'54'30" E I,PROVIDE ALL LABOR MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES NECESSARY To STRUCUPAL PANEL 8d (TABLE 3.9) L 75.00 �nstulled,replaced Or COMPLETE ALL WOOD AND PLASTIC WORK REQUIRED BY THE DRAWINGS AS SPECIFIED HEREIN,OR FIBERBOARD PANELS U7 00 C. p DWELLIN; OCCUPANCY PANCY OR REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK. 2.FASCIAS,SOFFITS AND E(TERIORTRIM SHALL MATCH EXISTING. 7/I G" 8d 3"EDGE/6'FIELD � I O � \ W/PUBLIC VATER repaired shalt conform 3.INTERIOR TRIM SHALL MATCH EXISTING. 25/32" 8d 3"EDGE/G'FIELD / N O CN , to Chapter 172 4.FRAMING ELEMENTS: GYPSUM WALLBOARD 5d coolers 7"EDGE/ 10"FIELD ---- - N 150 USE IS UNLAWFUL _ A.ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGIAS FIR-LARCH STRUCTURAL GRADE N0.2 HARDBOARD 8d (TABLE 3.9) LIL#7 z N 64'54�i W N \ ""' of the Town COCJG OR BETTER. PARTICALBOARDPANELS 8d (TABLE3.9) - (7] - _ - - 75 00 TIMB S _ IRON PIN WITHOUT CERTIFICA I ' B.ALL ENGINEERED LUMBER SHALL BE AS INDICATED ON DRAWINGS,AND SHALL BE INSTALLED,CUT DIAGONAL BOARD SHEATHING m - AND DRILLED IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS AND SPECIFICATIONS. III OR I"x8" 2-8d PER SUPPORT / GUY® 1 4.34' IRON PIN ' o EL 34.1 96.86' \ EL 33.2 OF OCCUPANCY C.ALL SHEATHING TO BE APA RATED,EXPOSURE 1,THICKNESS AS INDICATED. I N I O'OR WIDER 3-8d PER SUPPORT � 64 54 0 E D.ALL SUB FLOORING TO BE APA RATED 5TURD-I-FLOOR,EXP05URF 1,3/4'MIN.THICKNES. EL 34.0 E.ALL HEADERS G'-O"AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS,9'-0"AND OVER FLOOR SHEATHING S 4�1 WITH TRIPLE UPRIGHTS.ALL HEADERS SHALL BE A MIN.OF(2)2'x8'OR AS SHOWN ON DRAWING. 5TRUCURAL PANELS Q F.n9��` CD20.2' 8 9' F.SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AND FLOOR BEAMS AS PER BCNY5 2020 1"OR LE55 8d G"EDGE/ 12"FIELD WELL L���, OR AS NOTED @ 8'-O"O.C.MIN..PROVIDE 2-SPACE FOR AIR CIRCULATION IN ROOF. GREATER THAN 1" I Od 6"EDGE/6"FIELD I / I EL 31.4 �F �• o01 STY FRM. G.PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS(STAIRS,ETC,)OR AS NOTED ON DRAWINGS. DIAGONAL BOARD SHEATHING w H.PROVIDE DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR AS NOTED ON I NO OR 1 N8" 2-8d PER SUPPORT CONC. DRIVEWAY o oti GARAGE \ BASED ON SURVEY BY: DRAWING. I'x10'OR WIDER 3-8d PER SUPPORT / \ ,, GF 32.4 KENNETH M. WOYCHUK L.S. I.ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH RATED GALVANIZED METAL CONNECTORS BY"SIMPSON'OR APPROVED EQUAL. , O J.NAILING SCHEDULE SHALL BE AS PER BUILDING CODE of NEW YORK STATE 2020 AS A MINIMUM. � \ LAND SURVEYING AND DESIGN ALL 21 STUDS SHALL RECEIVE(5) 1 Od NAILS AT SILL AND PLATE.ALL EXTERIOR NAILS SHALL BE � � u APRIL,2023 GALVANIZED. SEE ATTACHED NAILING SCHEDULE. ( / I EL 31.9 K.PLYWOOD SHEATHING TO BE NAILED 8d NAILS @ 4'O.C.EXTERIOR EDGES AND Gd NAILS @ 12" EL 32,2 O.C.INTERMEDIATE. SEE ATTACHED NAILING 5CHE:DULE. _ n \ 06 APRIL,2023 L.ALL INTERIOR AND EXTERIOR FINISHES TO 13E SELECTED BY OWNER. / LOT 29 M.ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE 21.5 /�� 3 SCTM: 1000-78-9-27 3 3 TYPE CONNECTORS BY'SIMPSON"OR APPROVED EQUAL.FOR TIMBER PILE FOUNDATIONS,PROVIDE 2 MARCH 202 HURRICANE CLIPS AT ALL PERIMETER JOISTS TO GIRDER CONNECTIONS. DWELLING ~ Z1 ZONE: R-40 5.ALL NEW WINDOWS TO BE THERMAL INSULATED LOW-E GLA55,WITH ARGON GAS,IMPACT RE515TANT AS DWELLING / 1 STY. FR PROPOSED REQUIRED. W/WELL WATER & SEPTIC I W/WELL WATER I �" 35 -�D ELL N61- `�' INTERIOR AND I AREA: 9,557.3 SF (0.22 ACRES) G.LOAD PATHS ARE INDICATED BY SECTION DRAWINGS. I, 7.CONNECTIONS SHALL BE BUILT IN ACCORDANCE WITH AN51/AF/d PA WCFM-1995.(SEE NAILING OVER 150' ' N # �/N EXTERIOR ' LOT COVERAGE THESE PLANS ARE AN INSTRUMENT OF SCHEDULE) ;II 1000 GAL. /FFL 32.9 RENOVATIONS IN SERVICE AND ARE THE PROPERTY OF THE 8.FLASHING AT ALL WINDOW AND DOOR OPENINGS SHALL BE EPDM OR APPROVED RUBBERIZED / j/ LOT AREA: 9,557.3 SF MEMBRANE. 21' EXISTING FOOTPRINT I ARCHITECT.INFRINGEMENTS WILL 9.FLASHING AT ROOF CONNECTIONS,VAl1EY5,CHIMNEYS AND CRICKETS SHALL BE ALUMINUM. W / BILCO EXISTING HOUSE. 685 SF BE PROSECUTED 10. O.STEP FLASHING SHALL BE USED AT ALL INTER51`CTION5 OF SLOPED AND VERTICAL SURFACES,EXCEPT I - 24.2 EXISTING GARAGE: 380 SF STEP FLASHING AND COUNTER-AND CAP-FLASHING SHALL BE USED AT INTERSECTION OF ROOF AND I I I 2023 ALL RIGHTS RESERVED CHIMNEY,AND ROOF AND WALLS. 0 / 30.2 EL 30.3 I I 165 1 1.INSULATION SHALL BE GATT L.P. ATT INSULATION OF THICKNE55 INDICATED ON THE IDRAWING5 AND SHALL BE CORNER . TOTAL FOOTPRINT: 1065 SF 2-1/2 Ib. DENSITY FIBER-GLASS BATTS CONFORMING TO THE SPECIFICATIONS FOR PRE-FORMED FIBROUS LrI GLA55 INSULATION.NAAMM STANDARD SI, I b-70. CLOSED-CELL SPRAY-IN FOAM INSULATION(R-G.5 PER u INCH)BYIGYNENEORAPPROVEDEQUALSHALLBEPROVIDEDASINDICATEDONDRAWINGS. I IOLDDOWN 0 8'0X12'DEEP G I IOG5 / 9,557.3 = 1 1 . 1% 12.NEW INTERIOR DOORS SHALL MATCH EXISTING. 13. NEW HARDWARE SHALL MATCH EXISTING. C I LOT 30 IN I ALLOWED COVERAGE: 20% Robert I. Brown 14.GYPSUM BOARD SHALL BE EASED EDGE TYPE,CONFORMING TO ASTM C3G,AND SHALL BE + "SHEETROCK SW'BY U.S.GYPSUM CO.OR APPROVED EQUAL. GYPSUM WALLBOARD THICKNESS SHALL BE I I/2" PROPOSED 15.ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AND 5PACKLED THREE(3)COATS.ALL EXTERIOR 1 L P Z DRYWELL Architect, P.C. CORNERS SHALL HAVE METAL CORNER BEADS. O FINISHES EL 28.4 EL 28.0 Zo Bay Ave. Greenport NY 1. NEW LAMINATE FLOORS TO BE SELECTED BY OWNER AND INSTALLED USING MANUFACTURERS - - - _ - _ _ IRON PIN _ _ EL_28.2 _ _ REBAR DRAINAGE CALCULATIONS: INSTRUCTION. 1�2 2. EXISTING WOOD FLOORS SHALL BE SANDED AND REFINISHED. fj4_ ZONE I : 685 SF x 0. 17 = 116.5 CF in o@rl roWllarchitect.com 3. CERAMIC TILE FLOOR SHALL BE SELECTED BY OWNER AND INSTALLED WITH THIN SET ADHESIVE. / PROVIDE 1 ( 631-477-975Z 4.EXTERIOR PAINT SHALL BE LATEX ACRYLIC BY BENJAMIN MOORE OR APPROVED EQUAL,APPLIED \ N 65"09'20" w 97.24' ( ) 6' DIA x 5'-6"D DRYWELL 122.9 CF) IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. COLOR TO BE SELECTED. 5.EXISTING INTERIOR WALL5 AND CEILINGS IN ROOMS AFFECTED BY THE WORK SHALL BE CLEANED I \ AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED AND PAINTED.PAINTING SHALL BE TWO (2)COATS BENJAMIN MOORE AQUA PEARL LATEX PAINTED,COLOR TO BE SELECTED. RIDGE CROSS SECTION END VIEW G. INTERIOR TRIM SHALL BE SANDED SMOOTH,PRIMED,AND FINISHED WITH TWO(2)COATS DWELLING \ IT I A VIOLATION OF THE LAW FOR ANY PERSON, BENJAMIN MOORS LATEX ACRYLIC SEMI-GLOSS PAINT. UNLESS ACTING UNDER THE DIRECTION OFA W/PUBLIC WATER LOT 29A I / LICENSED ARCHITECT,TO ALTER ANY ITEM ON HVAC 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES \ VACANT I LOT 30A I DRAWING IN ANY WAY. ,SE AUTHORIZED AN ZED NECE55ARY TO PROVIDE A HVAC SYSTEM TO HEAT AND COOL THE LIVING SPACES AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND THE 2020 MECHANICAL W/GARAGE / ALTERATION MUSE BE NOTED,SEALED,AND CODE of NEW 13Y T STATE,OR REASONABLY IMPLIED A5 NECESSARY TO COMPLETE \ DESCRIBED IN ACCORDANCE WITH THE LAW. TO WORK.TO DWELLING 2.EXISTING BOILER AND RADIATORS TO REMAIN. i .- 3.NEW FORCED AIR CONDITIONING SYSTEM TO BE INSTALLED,NEW DUCTWORK ASI{ W/PUBLIC WATER W/PUBLIC WATER NECE55ARY 150 . �j \ � 4.PROVIDE AIR-HANDLERS,DUCTWO AND CONTROLS AS NECESSARY TO _ v COMPLETE THE WORK FOR AIR CONDITIONING IN ALL ZONES. GRK I \ M1 WELL PLUMBING1-14 I.PROVIDE ALL LABOR MATERIALS,TRANSPORTATION, EQUIPMENT,AND SERVICES ' '� NECESSARY TO COMPLETE ALL NEW PLUMBING WORK REQUIRED BY THE DRAWINGS ✓. , �r4 AND SPECIFICATIONS AND THE 2020 PLUMBING CODE of NEW YORK STATE,OR REASONABLY IMPLIED AS NECE55ARY TO COMPLETE THE WORK. I I 2.CONFORM TO THE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW IVITH ,M REGARDS TO WATER SAVING AND CONSERVATION. ALL FIXTURES SHALL BE OH THE APPROVED'LIST OF CERTIFIED WATER SAVING PLLIMBING FIXTURES"A5 PUBLI5IED BY THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. `3 3. ALL WORK ON THE PLUMBING SYSTEM SHALL BE PERFORMED BY OR UNDER THE SUPERVISION OF A PROPERLY LICENSED MASTER PLUMBER. UPON COMPLETICN,THE PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TOWN OF SOUTHOLD. CLIENT/OWNER 4.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS, CERTIFICATIONS,LICENSES AND INSPECTIONS ASS REQUIRED BY LOCAL,STATE,AND FEDERAL AUTHORITIES,AND ANY OTHER APPLICABLE JURISDICTION. OTTI ELECTRICAL I 1.FURNISH ALL LABOR,MATERIALS,EQUIPMENT,PLANT,TOOLS,AND SERVICES NECE55ARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL NEW IoiST ELECTRICAL SYSTEMS AND RELATED WORK INCLUDING,BUT NOT LIMITED TO: _ RV CONNECTIONS TO PREVIOUSLY INSTALLED ELECTRICAL SYSTEMS,WIRING,UGHTING, Jim SERVICES,FEEDERS,DISTRIBUTION AND PROTECTION EQUIPMENT,CONNECTIONS TO APPLIANCES, GROUNDING,AND ALL INCLUDING ALL CONNECTIONS AND DEVICES �/ 340 SUMMIT ROAD WITHIN THE SCOPE OF THE WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND AND 517CIFICATION5 AND AS NORMALLY SPECIFIED IN THI5 TYPE OF PROJECT AND I OUTHOLD, NY 11971 INCLUDING CONNECTIONS TO PREVIOUSLY INSTALLED TRANSFORMERS AND - - - - ELECTRICAL DISTRIBUTION SYSTEMS. 2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE 3 DWELLING I PROJECT TITLE of NEW YORK STATE,THE NATIONAL ELECTRICAL CODE,NFPA NO,70-2017(NEC), o W/WELL WATER LOCAL UTILITY STANDARDS,OCCUPATIONAL SAFETY AND HEALTH CAT(OSHA),THE N ADDITION AND NATIONAL ELECTRICAL MANUFACTURERS'ASSOCIATION(NEMA)AND ANY OTHER APPLICABLE CODES. IN THE EVENT OF CONFLICT,THE MORE STRINGENT WELL OVER 150' I DWELLING REQUIREMENTS WILL APPLY. 3.ALL PRODUCTS USED FOR ELECTRICAL WORK SHALL BEAR THE UNDERWRITERS _ W/WELL WATER & SEPTIC RENOVATIONS LABORATORIES,INC.LABEL AND BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY WILL BE INSTALLED. FLOOR OVER 150' 4.ALL WORK ON THE ELECTRICAL SYSTEM SHALL BE PERFORMED BY OR UNDER THE J0I5T = SUPERVISION OF A PROPERLY LICENSED MASTER ELECTRICIAN. 5.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,UCEN5E5 AND INSPECTIONS AS REQUIRED BY THE LOCAL,.STATE,AND FEDERAL AUTHORITIES. SITE P LA N AND ANY OTHER APPLICABLE JURISDICTION. DRAWING TITLE G.CARBON MONOXIDE DETECTORS IN CONFORMANCE WITH APPLICABLE CODES SHALL BE CONNECTED TO THE LIGHTING CIRCUITS WITH NO INTERVENING WALL SITE PLAN SWITCH. LINE CORD-CONNECTED,DIRECT PLUG-IN,AND BATTERY POWERED ALARMS SCALE: 1" = 20' ARE NOT ACCEPTABLE. ALARMS SHALL BE INSTALLED ON EACH LEVEL ON WHICH 5LEEMNG QUARTERS ARE LOCATED. -II EXISTING EXCEPT AS NOTED GENERAL NOTES 7.SMOKE DETECTORS IN CONFORMANCE WITH THE 2020 BUILDING CODE of NEW -..-..-..- YORK STATE,THE NFPA NATIONAL FIRE ALARM CODE NO.72-1 993 SHALL BE PROVIDED OUTSIDE EACH SEPARATE SLEEPING AREA,IN EACH 5PLEEPING AREA,AND UPLIFT CONNECTIONS ON EACH FLOOR LEVEL. CONTRACTOR SHALL COORDINATE WITH OWER'S ALARM COMPANY FOR SMOKE AND CONNECTIONS DETAIL SCALE BURGLAR ALARMS AS NECESSARY. 24 APRIL,2023 DRAWING No. ISSUES/REVISIONS D D BLUESTONE PAVERS EXISTING 2x4 CONSTRUCTION TO REMAIN REPAIR AND PATCH AS NECESSARY NEW POURED CONCRETE STEPS NEW R-1 5 BATT INSULATION IN ALL EXPOSED CAVITIES NEW 2x4 EXTERIOR CONSTRUCTION AND LANDING TO CODE(TYP.) REMOVE EXISTING WINDOW TO MATCH EXISTING ENLARGE EXISTING OPENING CD-X RATED PLYWOOD SHEATHING VAPOR BARRIER NEW WINDOW IN AS NECESSARY EXISTING OPENING (2) 2x8 HEADER NEW R-15 GATT INSULATION O m O B 5-3 1/2" NEW 3068 G'-8 1/2" 12'-0 3/4" 1 2'-0 3/4" EXTERIOR 6'-6" 6'-6" N NEW N 2668 c\j 13 REMOVE EXISTING CABINETS OPEN STORAGE LOFTS LO AND APPLIANCES w O J 145 SF NEW CABINETS AND APPLIANCE Q 1, 3 SELECTED BY OWNER _ _ w N W PLYWOOD SUBFLOOK E NEW BUILT-IN EXISTING BEDROOM 1 O '9 N C C Z _ NEW WOOD FLOORING TOOL �„ w C >-NEWWINDOWINO - u BE SELECTED BY OWNER �� PANTRY N _ 1 EXISTING OPENING O N NEWY2"5HEETKOCK ON WALLS AND CEILING N EXISTING KITCHEN TAPE, SPACKLE, AND PAINT 3 COATS BLUESTONE PAVERS NEW LAMINATE TILE FLOORING TO BE SELECTED BY OWNER N NEW POURED CONCRETE STEPS PROPOSED POWDER ROOM AND LANDING TO CODE(TYP.) NEW NEW LO 2x4 INTERIOR CONSTRUCTION 36" HANDRAIL (2) 2x 10 END JOIST NOISE CANCELING INSULATION2668 2068 NEW LAMINATE TILE FLOORING TO BE SELECTED TO CODE (TYP.) REMOVE EXISTING WALL ? Z BY OWNER w SINK O NEW FIXTURES PROVIDED BY OWNER, IN5TAI I ED / 4 NEW 3068 J BY CONTRACTOR in m NEW PLUMBING TO CONNECT WITH EXISTING IN 1 EXTERIOR 2 2 = BA5MENT NEW A NE 3 2"x 48" c� A A `O A NEW PREFABRICATED 2068 SHOWER NEW PREFABRIG TED O LADDER TO LOFT 'n O LADDER T6 LOFT 3 BY OTHERS d B OTHERS - �t B 24„ 0 B B 6 NEW VANITYED N 1� NEW CUSTOM 2668 ,�� DOOR TO ATTIC OD EXISTING LIVING ROOM NEW DOOR IN t C6y�IQ REMOVE EXISTING PICTURE WINDOW _ EXISTING OPENING OPEN T BE W KEFRAME EXISTING OPENING AS NECESSARY m NEW LAMINATE TILE FLOORING - 1` (2) 2x8 HEADER m TO BE SELECTED BY OWNER w B pA o t Q O ,� � UNFINISHED "-' ATTIC STORAGE _ = ra. EXISTING 2x4 CONSTRUCTION TO REMAIN EXISTING BEDROOM 2 CO N 't��r REPAIR AND PATCH AS NECESSARY NEW K-15 BATT INSULATION IN ALL EXPOSED CAVITIES N O fb+r1� N 1� NEW G-2" (2) 2x8 HEADER 6 2 2668 cn u APRIL,2023 5'-I" T 2'-1 I" 1 5-7 1/2" � ( 9'-4" 14'-9 I/2" 06 APRIL,2023 OB O OA O NEW 2x4 EXTERIOR CONSTRUCTION 23 MARCH,2023 TO MATCH EXISTING REMOVE EXISTING WINDOW CD-X RATED PLYWOOD SHEATHING F I K,5T F LO O f� PLAN ENLARGE EXISTING OPENING SECOND F LO O f� PLAN VAPOR BARRIER D AS NECESSARY NEW R-15 GATT INSULATION THESE PLANS ARE AN INSTRUMENT OF (2) 2x8 HEADER SERVICE AND ARE THE PROPERTY OF THE SCALE: I/4" = I'-O" SCALE: 1/4" = I'-0" ARCHITECT.INFRINGEMENTS WILL EXISTING EXCEPT AS NOTED EXISTING 2x4 CONSTRUCTION TO REMAIN EXISTING EXCEPT AS NOTED D BE PROSECUTED REPAIR AND PATCH AS NECESSARY NEW K-15 BATT INSULATION IN ALL EXPOSED CAVITIES 2o23 ALL RIGHTS RESERVED 7' 7' 2 ,2 Robert I. Brown lop' ►0 Architect, P.C. Q a05 Bay Ave. Greenport NY — — — info@ribrownarchitect.com F— 631-477-9752 � � I m IT IS A VIOLATION OF THE LAW FOR ANY PERSON, 'u m I UNLESS ACTING UNDER THE DIRECTION OF A JO LICENSED ARCHITECT,TO ALTER ANY ITEM ON lu THIS DRAWING IN ANY WAY.ANY N I I ALTERATION MUST BE NOTED,SEALED,AUTHORIZED w AND (fl z I I DESCRIBED IN ACCORDANCE WITH THE LAW. 00 m I I l WINDOW SCHEDULE lu 0 I I O 10 MODEL SIZE TYPE LITE QUANTITY NOTES �,KT; z z I I 3 A TW 304G 3'-211 x 4'-9" Dh 4 OVER 1 2 EGRESS " .y i I I 0 r, o B AR 281 2'-8B X 1 '-511 AWNING 2 7 REMOVE EXISTING ROOF w C AR 251 2 I x I 5 AWNING ;. . CENTERED OVER AND ROOF STRUCTURE N ' �' � �� 2 TEMPERED GLASS IN BATHROOM FRONT DOOR I ( m NEW 2x 10 RAFTERS @ 16"o.c. 0 D TW 2 103 10 3'-0" x 41- I " DH 4 OVER I 2 CLIENT/OWNER 7.5"CLOSED CELL SPRAY-IN FOAM I >- �- ii �- �i INSULATION (R-50) w E TW 2 102 10 3 O x 3 I DH 2 OVER 1 2 CD-X RATED PLYWOOD SHEATHING o VAPOR BARRIER I Q BLACK ASPHALT SHINGLES I w I-- F CW 125 2I-5u x 21-5u CASEMENT 4 LITE I STATIONARY ARVOTTI z Z JIM 340 SUMMIT ROAD N I SOUTHOLD, NY 119T v > I I PROJECT TITLE NOTE: ALL WINDOWS TO DE ANDERSEN 400 SERIES ADDITION AND NOTE: ALL WINDOWS TO BE WHITE INTERIOR AND EXTERIOR RENOVATIONS I DRAWING TITLE FLOOR PLANS AND ROOF PLAN K00 F PLAN_ SCALE SCALE: 1/4" = 1'-0" 24 APRIL,2023 1/4' -0" EXISTING EXCEPT AS NOTED DRAWING No. ISSUES/REVISIONS ® 12" NEW 30-YEAR BLACK ASPHALT SHINGLE ROOFING 12 10 B 3'-G" 3'-G" � 12 10 NEW GUTTERS TO BE SELECTED BY OWNER, NEW GUTTERS TO BE SELECTED BY OWNER, INSTALLED BY CONTRACTOR � INSTALLED BY CONTRACTOR 12" I I 12" 2'-0" v_— 1211 I NEW AZEK I x4 TRIMBOARD O E ' NEW AZEK I x4 TRIMBOAKD ON ALL WINDOWS AND DOORS ON ALL WINDOWS AND DOORS O O NEW VINYL SHINGLE SIDING O EW 30G6 IEW 30G NEW VINYL SIDING CORNERBOARDS TO MATCH EXTERIOR EXTERIOR CORNERBOARDS TO MATCH FRONT OF EXISTING GARAGE EXISTING GARAGE BLUESTOPdE PAVERS NEW POURED CONCRETE STEPS AND LANDING TO CODE(TYP.) I I I � 5'-0" 1BLUESTONE PAVERS 5'-011 I I BLUESTONE PAVERS r � u APRIL,2023 NEW POURED CONCRETE STEPS NEW POURED CONCRETE STEPS SIDE ELEVATiON (NORTH) AND LANDING TO CODE(TYP.) f RO NT E LEVATI O N (WEST) AND LANDING TO CODE(TYP.) o6APRIL,2023 23 MARCH,2023 SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" EXISTING EXCEPT AS NOTED EXISTING EXCEPT AS NOTED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED 2o23 ALL RIGHTS RESERVED Robert I. Brown Architect, P.C. ao5 Bay Ave. Greenport NY info@ribrownarchitect.com 631-477-9752 NEW 30-YEAR BLACK ASPHALT SHINGLE ROOFING 12 10 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A - LICENSED ARCHITECT,TO ALTER ANY ITEM ON THIS DRAWING IN ANY WAY.ANY AUTHORIZED ALTERATION MUST BE NOTED,SEALED,AND DESCRIBED IN ACCORDANCE WITH THE LAW. F s TO BE SELECTED BY OWNER, NEW GUTTERS TO BE SELECTED BY OWNER, INSTALLED BY CONTRACTOR INSTALLED BY CONTRACTOR w )�NEW AZEK I x4 TRIMBOARD NEW AZEK I x4 TRIMBOARD ON ALL WINDOWS AND DOORS B B C C B B ON ALL WINDOWS AND DOORS , q NEW VINYL SIDING O NEW VINYL SIDING CORNERBOARDS TO MATCH CORNEKBOARDS TO MATCH EXISTING GARAGE BLUESTONE PAVERS EXISTING GARAGE _ NEW POURED CONCRETE STEPS CLIENT OWNER AND LANDING TO CODE(TYP.) F A TTI JIM REAR ELEVATION (EAST) SIDE ELEVATION (NORTH) 340 SUMMIT ROAD SOUTHOLD, NY u971 SCALE: I/4" = I'-O" SCALE: I/4" = I'-O" EXISTING EXCEPT AS NOTED EXISTING EXCEPT AS NOTED PROJECT TITLE ADDITION AND RENOVATIONS DRAWING TIME ELEVATIONS SCALE 24 APRIL,2o23 >/4"=i-o" DRAWING No. ISSUES/REVISIONS NEW 1 3/4"x I I Y4" 2.OE MICROLLAM LVL RIDGE BEAM NEW 1 3/4"x I I Y4" 2.OE MICROLLAM LVL RIDGE BEAM NEW 2x6 CEILING JOISTS @ 16"O.C. Y a+t NEW 2xG CEILING JOISTS @ I G"O.G. REMOVE EXISTING ROOF REMOVE EXISTING ROOF 12 NEW 2x 10 RAFTERS @ I G"O.C. 12 NEW 2x 10 RAFTERS @ I G"O.C. 7.5"CLOSED CELL SPRAY-IN FOAM INSULATION (R-50) 7.5" CL05ED CELL SPRAY-IN FOAM INSULATION (R-50) 10 CD-X RATED PLYWOOD SHEATHING I O CD-X RATED PLYWOOD SHEATHING 3G" HANDRAIL VAPOR BARRIER Via_` VAPOR BARRIER TO CODE(IYP.) N BLACK ASPHALT SHINGLESj� ! BLACK ASPHALT SHINGLES UNFINISHED 4 ATTIC STORAGE --- - ----- -- ALIGN CENTER NEW 2x 10 JOISTS @ I G" I O.C. I xG AZEK TRIMBOARD NEW 2x I O JOISTS @ I G"O.C. WITH EDGE 1 I xG AZEK TRIMBOARD NEW GUTTERS ' V.I.F. NEW GUTTERS (2) 2x8 HEADER(TYP.) (2) 2x8 HEADER(fYP.) (2) 2x8 H EA ER(fYP.) _ (2) 2x8 HEADER p REMOVE EXISTING PICTURE WINDOW RPF RAM If EXISTING OPENING AS NECESSARY - (2) 2x8 HEADER EXISTING 2x4 CONSTRUCTION TO REMAIN EXISTING 2x4 CONSTRUCTION TO REMAIN REPAIR AND PATCH AS NECESSARY NEWYz"5HEETROCK ON WALLS AND CEILING REPAIR AND PATCH AS NECESSARY BLUESTONE PAVERS NEW R,15 BATT INSULATION IN ALL EXPOSED CAVITIES TAPE, SPACKLE, AND PAINT 3 COATS NEW R-15 BATT INSULATION IN ALL EXPOSED CAVITIES 4" POURED CONCRETE SLAB w/GxG WWM _ POURED CONCRETE STEPS EXISTING FLOOR JOISTS TO REMAIN EXISTING FLOOR J015T5 TO REMAIN TO CODE(fYP.) FRONT REAR REAR FRONT 8"POURED CONCRETE - FOUNDATION WALL I G"x 8" POURED CONCRETE FOOTING w/(3)#5 REPAR CONTINUOUS. MINIMUM 3'-0" BELOW GRADE ON EXISTING FOUNDATION TO REMAIN EXISTING FOUNDATION TO REMAIN UNDISTURBED SOIL ii 023 SECTION A S oECTION LJ APRIL,6 APRIL,,2o2 aoa3 SCALE: 1/4" = I'-0" SCALE: 1/4" = I'-0" 23 MARCH,2023 EXISTING EXCEPT AS NOTED EXISTING EXCEPT AS NOTED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED 2o23 ALL RIGHTS RESERVED NEW 1 3/4"x 1 1 Y4" 2.OE MICROLLAM LVL RIDGE BEAM REMOVE EXISTING ROOF NEW 2x 10 RAFTERS @ I G"O.C. Robert I. Brown 7.5" CLOSED CELL SPRAY-IN FOAM INSULATION (R 50) CD-X RATED PLYWOOD SHEATHING VAPOR BARRIER Architect, P.C. NEW 13/4"x I I Y4' 2.0E MICROLLAM LVL RIDGE BEAM BLACK ASPHALT SHINGLES # 44# tj# fill #4 #V =- � a tt �+ - Zo Bay Ave. Greenport NY info@ribrownarchitect.com 631-477-9752 I' I NEW 2xG CEILING JOISTS @ I G"O.C. REMOVE EXISTING ROOF NEW 2xG CEILING JOISTS @ I G" D.C. 12 jl -- T NEW 2x 10 RAFTERS @ I G"O.G. �I �I 7.5" CLOSED CELL 5PRAY-IN FOAM INSULATION (R 50) NEWy"SHEETROCK ON ALLS AND CEILING IT ISA VIOLATION OF THE LAW FORAM PERSON, 10 CD-X RATED PLYWOOD SHEATHING TAPE, SPACKLE, AND P NT 3 COATS O 2x8 HEADER(TYP.) UNLESS ACTING UNDER THE DIRECTION OFA VAPOR BARRIER 3G" HANDRAIL LICENSED ARCHITECT,TO ALTER ANY ITEM ON o T BLACK ASPHALT SHINGLES r TO CODE (fYP.) THIS DRAWING W ANY WAY.ANY AUTHORIZED NEW 2x4 EXTERIOR CONSTRUCTION ALTERATION MUST BE NOTED,SEALED,AND I' TO MATCH EXISTING DESCRIBED IN ACCORDANCE WITH THE LAW. 2x4 KNEE WALL 3/4' PLYWOOD S BFLO0R CD-X RATED PLYWOOD SHEATHING VAPOR BARRIER ' ON N STORAGE LO NEW LAMINATE OORING i ... TO BE SELECTS BY OWNER NEW R-1 5 BATT INSULATION µ' NEW 2x I 0 J015TS @ I G"O.C. NEW 2x I O JOISTS @ I G"O.C. " W�-�i s t'.' `+ I xG AZEK TRIMBOARD i xG AZEK TRIMBOARD 5-9 I 0-4 `. NEW GUTTERS (2) 2x8 HE (TYP-) (2) 2x8 HEADER(IYPJ 2' (2) 2x8 HEADER CfYP.) +� NEW PREFABRICATED w NEW 30G8 EXTERIOR q / TO BE SELECTED BY OWNER LADDER TO LOFT / REMOVE EXISTING CABINETS BY OTHERS e AND APPLIANCES J EXISTING 2x4 CONSTRUCTION TO REMAIN NEW CABINETS AND APPLIANCE REPAIR AND PATCH AS NECESSARY SELECTED BY OWNER m NEW R-15 GATT INSULATION IN ALL EXPOSED CAVITIES CLIENT/OWNER!' BLUESTONE PAVERS NEW LAMI ATE TILE FLOORING NEW LAMINATE TILE FLOORING 4" POURED CONCRETE SLAB TO BE SE ECTED BY OWNER TO BE SELECTED BY OWNER w/GxG WWM EXISTING FLOOR JO15T5 TO REMAIN POURED CONCRETE STEPS N N IN IN N L N N A OTTI TO CODE GW.) EXISTING FLOOR JOISTS TO REMAIN FRONT REAR Jim 8" POURED CONCRETE - 340 SUMMIT ROAD FOUNDATION WALL m SOUTHOLD, NY u97i I G"x 8" POURED PROJECT TITLE CONCRETE FOOTING ADDITION AND w/(3)#5 REPAR COBELO S. MINIMUM RENOVATIONS 3'-0"BELOW GRADE ON EXISTING FOUNDATION TO REMAIN LNDISTURBED SOIL EXISTING FOUNDATION TO REMAIN DRAWING TITLE SECTION C CONSTRUCTION SCALE: 1/4" = 1'_0" SECTION D SECTIONS EXISTING EXCEPT AS NOTED SCALE: I/4" = I'-O" EXISTING EXCEPT AS NOTED SCALE 24 APRIL,2023 1/4"=i-o" DRAWING No. ISSUES/REVISIONS FRI DG / / EXISTING OUTLETS TO REMAIN ®= GFI / 1 \ / I I i (� GFI 1` � / � EXTEND EX15TING BASEBOARD RADIATOR OVEN \ \ s SD SYSTEM TO LOFT AS � \—3 F� NECESSARY \\ i 3 469- $1 O ` I a _ TO / ® TO - LOFT FIRST \\ \ � /G i FLOOR / EXISTING OUTLETS EXISTING OUTLETS TO REMAIN TO REMAIN n APRIL,2023 o6 APRIL,2o23 23 MARCH,2o23 NOTE: NOTE: NOTE: NOTE: F I R5T F LO O K PLAN EXTEND EXISTING NEW CENTRAL AIR CONDITIONING SECOND FLOOR PLAN THESE PLANS ARE AN INSTRUMENT OF BASEBOARD RADIATOR SYSTEM TO BE INSTALLED. EXTEND EXISTING NEW CENTRAL AIR CONDITIONING SERVICE AND ARE THE PROPERTY OF THE BASEBOARD RADIATOR SYSTEM TO BE INSTALLED. SCALE: 1/4" = P-0" SYSTEM TO LOFT AS EQUIPMENT LOCATED IN 5CALE: 1/4" = P-O" SYSTEM TO LOFT AS EQUIPMENT LOCATED IN ARCHITECT.INFRINGEMENTS WILL EXISTING EXCEPT AS NOTED NECESSARY BASEMENT AS NECESSARY EXISTING EXCEPT AS NOTED NECESSARY BASEMENT AS NECESSARY BE PROSECUTED 2o23 ALL RIGHTS RESERVED Robert I. Brown Architect, P.C. zo5 Bay Ave. Greenport NY LEGEND info@ribrownarchitect.com 631-477-9752 LIGHT SWITCH 3 = THREE WAY D = DIMMER ® JAM SWITCH IT IS A VIOLATION OF THE LAW FOR ANY PERSON, OUTLET : UNLESS ACTING UNDER THE DIRECTION OFA GFI= GROUND FAULT INTERUPT LICENSED ARCHITECT,TO ALTER ANY ITEM ON 220 = 220 VOLT THIS DRAWING IN ANY WAY.ANY AUTHORIZED 4 = QUAD OUTLET ALTERATDESCRIBEDON MUST IN ACCORE NOTED,DANCE SEALED, FIXTURE RDAN E WITH THE LAW. 5= SURFACE MOUNT PROVIDED BY OWNER K= R.ECE55ED PROVIDED BY CONTRACTOR FO WALL SCONCE PHONE L �is4s,V ON-- CABLE 5E NETWORK CABLE } �• ' Q SPEAKERS EMERGENCY LIGHT [Al ALARM KEYPAD Ep THERMOSTAT EXIT 0 ® VENT EXIT SD SMOKE DETECTOR A SPOTLIGHT CLIENT/O R EPH ELEC. PANEL HEATER AR- -V- 0TTl �p PHONE/COMM. Z JIM — — LIGHT TRACK w 340 SUMMIT ROAD PC PULL CHAIN 01 SOUTHOLD, NY 11971 FL PORTRAIT LIGHT 5'G"TO CLOCK OUTLET IJi PROJECT TITLE � I �► DIRECT LIGHTING ADDITION AND CO CARBON MONOXIDE DETECTOR RENOVATIONS OO FIRE ALARM STROBE DRAWING TITLE PLANS AND �- ELEVATIONS SCALE 24 APRIL,2o23 1/4"=i-o" DRAWING No.